Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 57
Filter
1.
Neth Heart J ; 32(6): 254-261, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38776038

ABSTRACT

BACKGROUND: Several ethnic minorities have an increased risk of cardiovascular events, but previous European trials that investigated clinical outcome after coronary stenting did not assess the patients' ethnic background. AIMS: To compare ethnic minority and Western European trial participants in terms of both cardiovascular risk profile and 1­year clinical outcome after percutaneous coronary intervention. METHODS: In the BIO-RESORT and BIONYX randomised trials, which assessed new-generation drug-eluting stents, information on patients' self-reported ethnic background was prospectively collected. Pooled patient-level data of 5803 patients, enrolled in the Netherlands and Belgium, were analysed in this prespecified analysis. The main endpoint was target vessel failure after 1 year. RESULTS: Patients were classified as belonging to an ethnic minority (n = 293, 5%) or of Western European origin (n = 5510, 95%). Follow-up data were available in 5772 of 5803 (99.5%) patients. Ethnic minority patients were younger, less often female, more often current smokers, more often medically treated for diabetes, and more often had a positive family history of coronary artery disease. The main endpoint target vessel failure did not differ between ethnic minority and Western European patients (3.5% vs 4.9%, hazard ratio 0.71, 95% confidence interval 0.38-1.33; p = 0.28). There was also no difference in mortality, myocardial infarction, and repeat revascularisation rates. CONCLUSIONS: Despite the unfavourable cardiovascular risk profile of ethnic minority patients, short-term clinical outcome after treatment with contemporary drug-eluting stents was highly similar to that in Western European patients. Further efforts should be made to ensure the enrolment of more ethnic minority patients in future coronary stent trials.

2.
Catheter Cardiovasc Interv ; 98(2): E188-E196, 2021 08 01.
Article in English | MEDLINE | ID: mdl-33694294

ABSTRACT

OBJECTIVES: To compare 2-year outcome following treatment with drug-eluting stents (DES) for acute myocardial infarction (MI) versus non-MI clinical syndromes. In acute MI patients, a stent-level comparison was performed, comparing Resolute Onyx versus Orsiro stents. BACKGROUND: In patients presenting with acute MI, higher adverse event rates have been reported. So far, no clinical results >1 year have been published of acute MI patients treated with Resolute Onyx. METHODS: This post-hoc analysis of the randomized BIONYX trial(NCT02508714) assessed the main outcome target vessel failure (TVF: cardiac death, target vessel MI, or target vessel revascularization) with Kaplan-Meier methods. RESULTS: Of all 2,488 trial participants, acute MI patients (n = 1,275[51.2%]) were significantly younger and had less comorbidities than non-MI patients (n = 1,213[48.8%]). TVF rates were lower in acute MI patients (77/1,275[6.1%] vs. 103/1,213[8.6%], HR:0.70, 95%-CI 0.52-0.94; plog-rank  = 0.02), mainly driven by target vessel revascularization (4.1 vs. 6.1%, plog-rank  = 0.03). Multivariate analysis showed no independent association of clinical syndrome with TVF (adjusted-HR: 0.81, 95%-CI 0.60-1.10; p = .17). In MI patients treated with Resolute Onyx (n = 626) versus Orsiro (n = 649), there was no difference in TVF (6.2 vs. 6.1%; plog-rank  = 0.97) and its components. There was only 1(0.2%) definite-or-probable stent thrombosis in RO-ZES and 8(1.2%) in O-SES (p = .053). CONCLUSIONS: Two years after treatment with thin-strut DES in this randomized trial, patients treated for acute MI had lower adverse event rates than non-MI patients. Yet, these findings were mainly attributable to between-group differences in patient and lesion characteristics. In patients who underwent PCI for acute MI, both Resolute Onyx and Orsiro showed favorable and similar 2-year outcomes.


Subject(s)
Drug-Eluting Stents , Myocardial Infarction , Percutaneous Coronary Intervention , Everolimus , Humans , Percutaneous Coronary Intervention/adverse effects , Prosthesis Design , Sirolimus , Stents , Treatment Outcome
3.
Am Heart J ; 228: 109-115, 2020 10.
Article in English | MEDLINE | ID: mdl-32882569

ABSTRACT

BACKGROUND: Patients aged ≥80 years are often treated with new-generation drug-eluting stents (DES), but data from randomized studies are scarce owing to underrepresentation in most trials. We assessed 1-year clinical outcome of octogenarians treated with new-generation DES versus younger patients. METHODS: We pooled patient-level data of 9,204 participants in the TWENTE, DUTCH PEERS, BIO-RESORT, and BIONYX (TWENTE I-IV) randomized trials. The main clinical end point was target vessel failure (TVF), a composite of cardiac death, target vessel-related myocardial infarction (MI), or clinically indicated target vessel revascularization. RESULTS: The 671 octogenarian trial participants had significantly more comorbidities. TVF was higher in octogenarians than in 8,533 patients <80 years (7.3% vs 5.3%, hazard ratio [HR]: 1.36, 95% CI: 1.0-1.83, P = .04). The cardiac death rate was higher in octogenarians (3.9% vs 0.8%, P < .001). There was no significant between-group difference in target vessel MI (2.3% vs 2.3%, P = .88) and repeat target vessel revascularization (1.9% vs 2.8%, P = .16). In multivariate analyses, age ≥ 80 years showed no independent association with TVF (adjusted HR: 1.04, 95% CI: 0.76-1.42), whereas the risk of cardiac death remained higher in octogenarians (adjusted HR: 3.38, 95% CI: 2.07-5.52, P < .001). In 6,002 trial participants, in whom data on major bleeding were recorded, octogenarians (n = 459) showed a higher major bleeding risk (5.9% vs 1.9%; HR: 3.08, 95% CI: 2.01-4.74, P < .001). CONCLUSIONS: Octogenarian participants in 4 large-scale randomized DES trials had more comorbidities and a higher incidence of the main end point TVF. Cardiac mortality was higher in octogenarians, whereas there was no increase in MI or target vessel revascularization rates. Treatment of octogenarian patients with new-generation DES appears to be safe and effective.


Subject(s)
Drug-Eluting Stents/classification , Everolimus/pharmacology , Myocardial Infarction , Postoperative Complications , Sirolimus/analogs & derivatives , Sirolimus/pharmacology , Aged, 80 and over , Coronary Artery Disease/diagnosis , Coronary Artery Disease/surgery , Female , Humans , Immunosuppressive Agents/pharmacology , Male , Myocardial Infarction/diagnosis , Myocardial Infarction/etiology , Myocardial Infarction/mortality , Percutaneous Coronary Intervention , Postoperative Complications/diagnosis , Postoperative Complications/mortality , Reoperation/methods , Reoperation/statistics & numerical data , Risk Adjustment/methods , Risk Factors , Treatment Outcome
4.
Catheter Cardiovasc Interv ; 96(2): E110-E118, 2020 08.
Article in English | MEDLINE | ID: mdl-31625262

ABSTRACT

BACKGROUND: Patients with coronary disease may have unknown diabetes or prediabetes. We evaluated 3-year outcomes after percutaneous coronary intervention (PCI) with contemporary drug-eluting stents (DES) in patients with silent diabetes, prediabetes, and normoglycemia. METHODS: All BIO-RESORT trial (NCT01674803) participants without known diabetes, enrolled at our center, were invited for oral glucose tolerance testing (OGTT) and measurements of fasting plasma glucose and glycated hemoglobin (HbA1c). RESULTS: OGTT detected silent diabetes in 68 (6.9%), prediabetes in 132 (13.4%), and normoglycemia in 788 (79.8%) of all 988 study participants. Follow-up was available in 986 (99.8%) patients. The main endpoint target vessel failure (TVF: cardiac death, target vessel-related myocardial infarction [MI], or target vessel revascularization) differed between groups (14.8, 9.9, and 5.6%; p = .002), driven by MI during the first 48 hr and by cardiac death (p < .001; p = .026). Between 48 hr and 3-years, there was no significant between-group difference in TVF, target vessel MI, and target vessel revascularization. Multivariable analysis demonstrated that silent diabetes was independently associated with TVF (adjusted HR: 2.52, 95%-CI: 1.26-5.03). An alternative diagnostic approach-HbA1c and fasting plasma glucose-detected silent diabetes and prediabetes in 33 (3.3%) and 217 (22.0%) patients, and normoglycemia in 738 (74.7%); TVF rates were 12.1, 7.9, and 6.0% (p = .23). CONCLUSION: In patients without known diabetes, abnormal glucose metabolism by OGTT was independently associated with higher 3-year TVF rates after PCI with contemporary DES. This difference was driven by periprocedural MI and cardiac death. After the first 48 hr, the rates of TVF, target vessel MI, and target vessel revascularization were low and did not differ significantly between metabolic groups.


Subject(s)
Blood Glucose/metabolism , Coronary Artery Disease/therapy , Diabetes Mellitus/diagnosis , Drug-Eluting Stents , Glucose Tolerance Test , Percutaneous Coronary Intervention/instrumentation , Prediabetic State/diagnosis , Aged , Asymptomatic Diseases , Biomarkers/blood , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Diabetes Mellitus/blood , Diabetes Mellitus/mortality , Female , Glycated Hemoglobin/metabolism , Humans , Male , Middle Aged , Netherlands , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Prediabetic State/blood , Prediabetic State/mortality , Predictive Value of Tests , Prospective Studies , Risk Factors , Time Factors , Treatment Outcome
5.
Nanotechnology ; 31(9): 095701, 2020 Feb 21.
Article in English | MEDLINE | ID: mdl-31703211

ABSTRACT

Zinc oxide (ZnO) hollow spheres with defined morphology and micro-/nanostructure are prepared by a hydrothermal synthesis approach. The materials possess fine-leaved structures at their particle surface (nanowall hollow micro spheres). Morphology control is achieved by citric acid used as an additive in variable relative quantities during the synthesis. The structure formation is studied by various time-dependent ex situ methods, such as scanning electron microscopy, x-ray diffraction, and Raman spectroscopy. The fine-leaved surface structure is characterized by high-resolution transmission electron microscopy techniques (HRTEM, STEM), using a high-angle annular dark field detector, as well as by differential phase contrast analysis. In-depth structural characterization of the nanowalls by drop-by-drop ex situ FE-SEM analysis provides insight into possible structure formation mechanisms. Further investigation addresses the thermal stability of the particle morphology and the enhancement of the surface-to-volume ratio by heat treatment (examined by N2 physisorption).

6.
Lancet ; 392(10154): 1235-1245, 2018 10 06.
Article in English | MEDLINE | ID: mdl-30253879

ABSTRACT

BACKGROUND: During the past decade, many patients had zotarolimus-eluting stents implanted, which had circular shape cobalt-chromium struts with limited radiographic visibility. The Resolute Onyx stent was developed to improve visibility while reducing strut thickness, which was achieved by using a novel composite wire with a dense platinum-iridium core and an outer cobalt-chromium layer. We did the first randomised clinical trial to assess the safety and efficacy of this often-used stent compared with the Orsiro stent, which consists of ultrathin cobalt-chromium struts. METHODS: We did an investigator-initiated, assessor-blinded and patient-blinded, randomised non-inferiority trial in an allcomers population at seven independently monitored centres in Belgium, Israel, and the Netherlands. Eligible participants were aged 18 years or older and required percutaneous coronary intervention with drug-eluting stents. After guide wire passage with or without predilation, members of the catheterisation laboratory team used web-based computer-generated allocation sequences to randomly assign patients (1:1) to either the Resolute Onyx or the Orsiro stent. Randomisation was stratified by sex and diabetes status. Patients and assessors were masked to allocated stents, but treating clinicians were not. The primary endpoint was target vessel failure at 1 year, a composite of cardiac death, target-vessel-related myocardial infarction, and target vessel revascularisation, and was assessed by intention to treat (non-inferiority margin 2·5%) on the basis of outcomes adjudicated by an independent event committee. This trial is registered with ClinicalTrials.gov, number NCT02508714. FINDINGS: Between Oct 7, 2015, and Dec 23, 2016, 2516 patients were enrolled, 2488 of whom were included in the intention-to-treat analysis (28 withdrawals or screening failures). 1243 participants were assigned to the Resolute Onyx group, and 1245 to the Orsiro group. Overall, 1765 (70·9%) participants presented with acute coronary syndromes and 1275 (51·2%) had myocardial infarctions. 1-year follow-up was available for 2478 (99·6%) patients. The primary endpoint was met by 55 (4·5%) patients in the Resolute Onyx group and 58 (4·7%) in the Orsiro group. Non-inferiority of Resolute Onyx to Orsiro was thus established (absolute risk difference -0·2% [95% CI -1·9 to 1·4]; upper limit of the one-sided 95% CI 1·1%; pnon-inferiority=0·0005). Definite or probable stent thrombosis occurred in one (0·1%) participant in the Resolute Onyx group and nine (0·7%) in the Orsiro group (hazard ratio 0·11 [95% CI 0·01-0·87]; p=0·0112). INTERPRETATION: The Resolute Onyx stent was non-inferior to Orsiro for a combined safety and efficacy endpoint at 1-year follow-up in allcomers. The low event rate in both groups suggests that both stents are safe, and the very low rate of stent thrombosis in the Resolute Onyx group warrants further clinical investigation. FUNDING: Biotronik and Medtronic.


Subject(s)
Coronary Artery Disease/surgery , Drug-Eluting Stents , Percutaneous Coronary Intervention/instrumentation , Prosthesis Design , Absorbable Implants , Adult , Aged , Aged, 80 and over , Chromium Alloys , Drug-Eluting Stents/adverse effects , Equivalence Trials as Topic , Female , Follow-Up Studies , Humans , Intention to Treat Analysis , Male , Middle Aged , Polymers , Prospective Studies , Single-Blind Method , Treatment Outcome
7.
Cardiovasc Drugs Ther ; 32(6): 567-576, 2018 12.
Article in English | MEDLINE | ID: mdl-30143879

ABSTRACT

PURPOSE: Patients with high bleeding risk (HBR) who undergo percutaneous coronary intervention also have an increased risk of ischemic events and represent an overall high-risk population. The coating of durable polymer drug-eluting stents (DP-DES) may induce inflammation and delay arterial healing, which might be reduced by novel biodegradable polymer DES (BP-DES). We aimed to evaluate the safety and efficacy of treating HBR patients with very thin-strut BP-DES versus thin-strut DP-DES. METHODS: Participants in BIO-RESORT (NCT01674803), an investigator-initiated multicenter, randomized all-comers trial, were treated with very thin-strut BP-DES (Synergy or Orsiro) or thin-strut DP-DES (Resolute Integrity). For the present analysis, patients were classified following HBR criteria based on previous trials. The primary endpoint was target vessel failure: a composite of cardiac death, target vessel-related myocardial infarction, or target vessel revascularization at 1 year. RESULTS: Of all 3514 patients, 1009 (28.7%) had HBR. HBR patients were older (p < 0.001) and had more co-morbidities than non-HBR patients (p < 0.001). At 1-year follow-up, HBR patients had significantly higher rates of target vessel failure (6.7 vs. 4.2%, p = 0.003), cardiac death (1.9 vs. 0.4%, p < 0.001), and major bleeding (3.3 vs. 1.5%, p = 0.001). Of all 1009 HBR patients, 673 (66.7%) received BP-DES and 336 (33.3%) had DP-DES. The primary endpoint was met by 43/673 (6.5%) patients treated with BP-DES and 24/336 (7.3%) treated with DP-DES (HR 0.88 [95%CI 0.54-1.46], p = 0.63). There were no significant between-group differences in the most global patient-oriented clinical endpoint (9.7 vs. 10.5%, HR 0.92 [95%CI 0.61-1.39], p = 0.69) and other secondary endpoints. CONCLUSIONS: At 1-year follow-up, very thin-strut BP-DES showed similar safety and efficacy for treating HBR patients as thin-strut DP-DES.


Subject(s)
Absorbable Implants , Coronary Artery Disease/surgery , Drug-Eluting Stents , Hemorrhage/chemically induced , Percutaneous Coronary Intervention/instrumentation , Platelet Aggregation Inhibitors/adverse effects , Polymers/chemistry , Aged , Aged, 80 and over , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Female , Hemorrhage/mortality , Humans , Male , Middle Aged , Netherlands , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Prosthesis Design , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome
8.
Lancet ; 388(10060): 2607-2617, 2016 11 26.
Article in English | MEDLINE | ID: mdl-27806902

ABSTRACT

BACKGROUND: In patients with coronary artery disease, treated with durable polymer-coated drug-eluting stents, the life-long presence of the polymer might delay arterial healing. Novel very thin strut biodegradable polymer stents, which leave only a bare metal stent after polymer resorption, might improve long-term outcome. We investigated in allcomers the safety and efficacy of three stents eluting either everolimus, sirolimus, or zotarolimus, often clinically used but never compared, of which the biodegradable polymer everolimus-eluting stent was never before assessed in allcomers. METHODS: The large-scale, investigator-initiated, multicentre, assessor and patient blinded, three-arm, randomised, BIO-RESORT non-inferiority trial was done at four clinical sites in the Netherlands. All-comer patients were aged 18 years or older, capable of providing informed consent, and required a percutaneous coronary intervention with drug-eluting stent implantation according to clinical guidelines or the operators' judgment. Exclusion criteria were: participation in another randomised drug or device study before reaching the primary endpoint of that study; planned surgery necessitating interruption of dual antiplatelet therapy within the first 6 months; known intolerance to components of the investigational product or medication required; uncertainty about the adherence to follow-up procedures or an assumed life expectancy of less than 1 year; or known pregnancy. Web-based computer-generated allocation sequences randomly assigned patients (1:1:1) to treatment with very thin strut biodegradable polymer everolimus-eluting or sirolimus-eluting stents (which differ substantially in type, amount, distribution, and resorption speed of their respective coating), or thin strut durable polymer zotarolimus-eluting stents. The primary endpoint was a composite of safety (cardiac death or target vessel-related myocardial infarction) and efficacy (target vessel revascularisation) at 12 months of follow up with a very thin strut biodegradable polymer of either everolimus-eluting or sirolimus-eluting stents, compared with durable polymer zotarolimus-eluting stents, analysed by intention to treat (non-inferiority margin 3·5%). This trial was registered with ClinicalTrials.gov, number NCT01674803. FINDINGS: From Dec 21, 2012, to Aug 24, 2015, 3514 patients were enrolled and analysed, of whom 2449 (70%) had acute coronary syndromes, which included 1073 (31%) ST-elevation myocardial infarctions. 12 month follow-up of 3490 (99%) patients (three lost to follow-up; 21 withdrawals) was available. The primary endpoint was met by 55 (5%) of 1172 patients assigned to everolimus-eluting stents, 55 (5%) of 1169 assigned to sirolimus-eluting stents and 63 (5%) of 1173 assigned to zotarolimus-eluting stents. Non-inferiority of the everolimus-eluting stents and sirolimus-eluting stents compared with zotarolimus-eluting stents was confirmed (both -0·7% absolute risk difference, 95% CI -2·4 to 1·1; upper limit of one sided 95% CI 0·8%, pnon-inferiority<0·0001). Definite stent thrombosis (defined by the Academic Research Consortium) occurred in four (0·3%) of 1172 patients who were allocated to everolimus-eluting stents, four (0·3%) of 1169 patients who were allocated to sirolimus-eluting stents, and three (0·3%) of 1173 patients who were allocated to zotarolimus-eluting stents (log-rank p=0·70 for both comparisons with zotarolimus-eluting stents). INTERPRETATION: At 12 month follow-up, both very thin strut drug-eluting stents with dissimilar biodegradable polymer coatings (eluting either everolimus or sirolimus) were non-inferior to the durable polymer stent (eluting zotarolimus) in treating allcomers with a high proportion of patients with acute coronary syndromes. The absence of a loss of 1 year safety and efficacy with the use of these two biodegradable polymer-coated stents is a prerequisite before assessing their potential longer-term benefits. FUNDING: Biotronik, Boston Scientific, and Medtronic.


Subject(s)
Acute Coronary Syndrome/surgery , Anti-Bacterial Agents/therapeutic use , Drug-Eluting Stents , Everolimus , Sirolimus/analogs & derivatives , Sirolimus/therapeutic use , Absorbable Implants , Aged , Anti-Bacterial Agents/administration & dosage , Coronary Disease/surgery , Female , Humans , Immunosuppressive Agents/therapeutic use , Male , Middle Aged , Netherlands , Percutaneous Coronary Intervention/instrumentation , Percutaneous Coronary Intervention/methods , Polymers , Sirolimus/administration & dosage , Sirolimus/analysis , Treatment Outcome
9.
Cardiology ; 137(4): 207-217, 2017.
Article in English | MEDLINE | ID: mdl-28445871

ABSTRACT

OBJECTIVE: Limited data is available on the long-term outcome of patients with increased cardiovascular event risk, treated with newer-generation durable polymer drug-eluting stents (DES). METHODS: We therefore assessed 3-year follow-up data of high-risk versus low- to intermediate-risk patients of the randomized DUTCH PEERS trial (NCT01331707). In both risk groups we also compared patients treated with Resolute Integrity versus Promus Element DES. Patients were categorized as "high-risk" if they met ≥1 of the following criteria: (1) diabetes (17.9%); (2) previous myocardial infarction (21.9%); (3) previous coronary revascularization (25.8%); (4) chronic renal failure (3.5%); (5) left ventricular ejection fraction ≤30% (1.5%); and (6) age ≥75 years (17.3%). RESULTS: At the 3-year follow-up, the incidence of the composite endpoint target vessel failure (TVF) (13.2 vs. 7.5%; logrank p < 0.001) and 2 of its components - cardiac death (4.7 vs. 1.5%; logrank p < 0.001) and target vessel revascularization (7.3 vs. 4.7%; logrank p = 0.03) - was higher in high-risk (n = 957) versus low- to intermediate-risk patients (n = 854). Among high-risk patients, treatment with Resolute Integrity (n = 481) and Promus Element stents (n = 476) was similarly safe and efficacious (TVF: 13.3 vs. 13.1%; logrank p = 0.95; definite-or-probable stent thrombosis: 1.7 vs. 1.7%; logrank p = 1.00). CONCLUSIONS: The newer-generation Resolute Integrity and Promus Element stents showed similar results in terms of safety and efficacy for treating high-risk patients, who had significantly higher event rates than patients with low-to-intermediate risk.


Subject(s)
Coronary Artery Disease/therapy , Drug-Eluting Stents , Everolimus/administration & dosage , Percutaneous Coronary Intervention/instrumentation , Sirolimus/analogs & derivatives , Aged , Coronary Artery Disease/mortality , Female , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Multivariate Analysis , Myocardial Infarction/etiology , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Proportional Hazards Models , Prospective Studies , Prosthesis Design , Risk Factors , Single-Blind Method , Sirolimus/administration & dosage , Thrombosis/etiology , Treatment Outcome
10.
Am Heart J ; 176: 28-35, 2016 Jun.
Article in English | MEDLINE | ID: mdl-27264217

ABSTRACT

BACKGROUND: Treatment of lesions in small vessels was associated with worse clinical outcome, and various definitions of "small vessels" have been used. Data with novel drug-eluting stents are scarce. METHODS: To compare the outcome of patients with vs without small-vessel treatment, we assessed 2-year follow-up data of the DUTCH PEERS randomized trial (ClinicalTrials.gov: NCT01331707), in which 1,811 all-comers were treated with contemporary zotarolimus-eluting (Resolute Integrity) or everolimus-eluting (Promus Element) stents. Primary end point was target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction, and target lesion revascularization. RESULTS: The rates of TLF (9.5% vs 5.4%; P log rank = .001) and 2 individual components thereof-target vessel myocardial infarction (3.1% vs 1.3%; P log rank = .006) and target lesion revascularization (4.8% vs 2.8%; P log rank = .02)-were higher among 798 (44.1%) patients treated in at least one small vessel (<2.50 mm by quantitative coronary angiography). Multivariate analysis with propensity score adjustment demonstrated that treatment of small-vessel lesions independently predicted TLF at 2-year follow-up (hazard ratio 1.60, 95% CI 1.09-2.34). Patients with the smallest target vessel being <2.25 mm had TLF rates similar to patients with smallest target vessels of 2.25 to <2.50 mm; however, patients treated in vessels no smaller than 2.50 to <3.00 mm and patients treated in vessels ≥3.00 mm had lower TLF rates (9.3%, 9.8%, 5.0%, and 5.8%, respectively; P log rank = .009). CONCLUSION: Patients treated with novel drug-eluting stents in small-vessel lesions had higher adverse event rates than did patients who had no small-vessel treatment. Our data suggest that with current stents, a vessel diameter <2.50 mm is a suitable threshold to identify small target vessels.


Subject(s)
Coronary Artery Disease/complications , Coronary Vessels , Drug-Eluting Stents/adverse effects , Everolimus/therapeutic use , Myocardial Infarction , Percutaneous Coronary Intervention , Sirolimus/analogs & derivatives , Aged , Coronary Angiography/methods , Coronary Artery Disease/diagnosis , Coronary Vessels/diagnostic imaging , Coronary Vessels/pathology , Female , Humans , Immunosuppressive Agents/therapeutic use , Kaplan-Meier Estimate , Male , Middle Aged , Myocardial Infarction/etiology , Myocardial Infarction/mortality , Myocardial Infarction/therapy , Organ Size , Outcome and Process Assessment, Health Care , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/instrumentation , Percutaneous Coronary Intervention/methods , Sirolimus/therapeutic use
11.
Catheter Cardiovasc Interv ; 85(3): E76-82, 2015 Feb 15.
Article in English | MEDLINE | ID: mdl-25339110

ABSTRACT

OBJECTIVE: To compare long-term outcome of patients treated for chronic total occlusion (CTO) lesions versus patients treated for non-CTO lesions only. BACKGROUND: Percutaneous coronary interventions (PCI) for CTO lesions generally have a higher adverse event risk than PCI for non-CTO lesions. However, long-term outcome data from prospective studies with second-generation drug-eluting stent (DES) use in CTO lesions is scarce. METHODS: We analyzed in this substudy of the TWENTE trial the data of 674 patients, who had stable angina and were electively treated with second-generation DES (Resolute zotarolimus-eluting or Xience V everolimus-eluting stents). Main outcome parameter was target lesion failure (TLF), a composite of cardiac death, target vessel-related myocardial infarction (MI), or target lesion revascularization (TLR). RESULTS: Patients with CTO lesions (n = 59, 8.8%) were more often treated for lesions in small vessels (94.9% vs. 63.1%, P < 0.001), long lesions (52.5% vs. 17.7%, P < 0.001) and multiple vessels (42.4% vs. 22.4%, P < 0.001), and were less often males (62.7% vs. 74.6%, P < 0.05) than patients with non-CTO lesions (n = 615, 91.2%). J-CTO scores ≥2 were present in 56% of CTO lesions. Despite significant differences in characteristics of patients, lesions, and interventional procedures, the TLF rate at 3-year follow-up was similar for both groups (13.6% vs. 12.9%, P = 0.89). In addition, a patient-oriented composite endpoint (any death, MI or revascularization) did not differ between groups (18.6% vs. 18.8%, P = 0.97). CONCLUSION: Patients treated with second-generation DES for CTO lesions showed at 3-year follow-up an incidence of adverse clinical events that was low and similar to patients with non-CTO lesions only.


Subject(s)
Coronary Occlusion/therapy , Drug-Eluting Stents , Percutaneous Coronary Intervention/instrumentation , Aged , Cardiovascular Agents/administration & dosage , Chronic Disease , Coronary Occlusion/diagnosis , Coronary Occlusion/mortality , Everolimus/administration & dosage , Female , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Myocardial Infarction/etiology , Netherlands , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Prosthesis Design , Sirolimus/administration & dosage , Sirolimus/analogs & derivatives , Time Factors , Treatment Outcome
12.
Atherosclerosis ; 392: 117488, 2024 May.
Article in English | MEDLINE | ID: mdl-38598970

ABSTRACT

BACKGROUND AND AIMS: Previous studies in percutaneous coronary intervention (PCI) patients showed a higher 3-year adverse event risk, including all-cause mortality, in those with concomitant peripheral arterial disease (PADs). Ten-year data of mortality and causes of death are scarce. This analysis assessed PCI patients, treated with contemporary drug-eluting stents, the impact of concomitant PADs on very long-term mortality, and causes of death. METHODS: We assessed PCI all-comers from our center who participated in the TWENTE and DUTCH PEERS trials (clinicaltrials.gov:NCT01066650, NCT01331707), comparing patients with versus without PADs. Life status was checked in the Dutch Personal Records Database; causes of death were obtained from medical records. RESULTS: Of 2705 study patients, 668 (24.7%) died during follow-up: 88/212 (41.5%) patients with PADs and 580/2493 (23.1%) without PADs. In PADs patients, the 10-year rate of all-cause mortality was about twice as high as in patients without PADs (41.5% vs.23.1%, HR: 2.05, 95%-CI: 1.64-2.57, p<0.001). For both groups, the rates of patients dying from various causes of death were: cardiac (14.1% vs.6.8%), vascular (2.8% vs. 1.1%), non-cardiovascular (17.4% vs. 9.8%), and unclear causes (7.1% vs. 5.3%), without a statistically significant between-group difference. When multivariate analysis was adjusted for between-group differences in cardiovascular risk profile, PADs remained predictor of all-cause mortality (adjusted HR: 1.38, 95%-CI: 1.08-1.75, p=0.01). CONCLUSIONS: The 10-year all-cause mortality rate in PCI patients with concomitant PADs was almost twice as high as in those without PADs. Age and other traditional cardiovascular risk factors were higher in patients with PADs, but after correction for these confounders PADs still accounted for almost 40% increase in mortality.


Subject(s)
Coronary Artery Disease , Drug-Eluting Stents , Percutaneous Coronary Intervention , Peripheral Arterial Disease , Humans , Peripheral Arterial Disease/mortality , Peripheral Arterial Disease/therapy , Male , Female , Aged , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Coronary Artery Disease/mortality , Coronary Artery Disease/therapy , Coronary Artery Disease/complications , Time Factors , Treatment Outcome , Risk Factors , Netherlands/epidemiology , Cause of Death
13.
Eur Heart J Acute Cardiovasc Care ; 12(11): 774-781, 2023 Nov 16.
Article in English | MEDLINE | ID: mdl-37619976

ABSTRACT

AIMS: Patients with premature coronary artery disease (CAD) have a higher incidence of myocardial infarction (MI) than patients with non-premature CAD. The aim of the present study is to asess differences in clinical outcome after a first acute MI, percutaneously treated with new-generation drug-eluting stents between patients with premature and non-premature CAD. METHODS AND RESULTS: We pooled and analysed the characteristics and clinical outcome of all patients with a first MI (and no previous coronary revascularization) at time of enrolment, in four large-scale drug-eluting stent trials. Coronary artery disease was classified premature in men aged <50 and women <55 years. Myocardial infarction patients with premature and non-premature CAD were compared. The main endpoint was major adverse cardiac events (MACE): all-cause mortality, any MI, emergent coronary artery bypass surgery, or clinically indicated target lesion revascularization. Of 3323 patients with a first MI, 582 (17.5%) had premature CAD. These patients had lower risk profiles and underwent less complex interventional procedures than patients with non-premature CAD. At 30-day follow-up, the rates of MACE [hazard ratio (HR): 0.22, 95% confidence interval (CI): 0.07-0.71; P = 0.005), MI (HR: 0.22, 95% CI: 0.05-0.89; P = 0.020), and target vessel failure (HR: 0.30, 95% CI: 0.11-0.82; P = 0.012) were lower in patients with premature CAD. At 1 year, premature CAD was independently associated with lower rates of MACE (adjusted HR: 0.50, 95% CI: 0.26-0.96; P = 0.037) and all-cause mortality (adjusted HR: 0.24, 95% CI: 0.06-0.98; P = 0.046). At 2 years, premature CAD was independently associated with lower mortality (adjusted HR: 0.16, 95% CI: 0.05-0.50; P = 0.002). CONCLUSIONS: First MI patients with premature CAD, treated with contemporary stents, showed lower rates of MACE and all-cause mortality than patients with non-premature CAD, which is most likely related to differences in cardiovascular risk profile. TWENTE trials: TWENTE I, clinicaltrials.gov: NCT01066650), DUTCH PEERS (TWENTE II, NCT01331707), BIO-RESORT (TWENTE III, NCT01674803), and BIONYX (TWENTE IV, NCT02508714).


Subject(s)
Coronary Artery Disease , Drug-Eluting Stents , Myocardial Infarction , Percutaneous Coronary Intervention , Female , Humans , Male , Coronary Artery Disease/complications , Coronary Artery Disease/surgery , Drug-Eluting Stents/adverse effects , Myocardial Infarction/epidemiology , Myocardial Infarction/surgery , Myocardial Infarction/drug therapy , Percutaneous Coronary Intervention/methods , Risk Factors , Treatment Outcome , Middle Aged
14.
Front Cardiovasc Med ; 10: 1160201, 2023.
Article in English | MEDLINE | ID: mdl-37745109

ABSTRACT

Objectives: We assessed differences in risk profile and 3-year outcome between patients undergoing percutaneous coronary intervention (PCI) for premature and non-premature coronary artery disease (CAD). Background: The prevalence of CAD increases with age, yet some individuals develop obstructive CAD at younger age. Methods: Among participants in four randomized all-comers PCI trials, without previous coronary revascularization or myocardial infarction (MI), we compared patients with premature (men <50 years; women <55 years) and non-premature CAD. Various clinical endpoints were assessed, including multivariate analyses. Results: Of 6,171 patients, 887 (14.4%) suffered from premature CAD. These patients had fewer risk factors than patients with non-premature CAD, but were more often smokers (60.7% vs. 26.4%) and overweight (76.2% vs. 69.8%). In addition, premature CAD patients presented more often with ST-segment elevation MI and underwent less often treatment of multiple vessels, and calcified or bifurcated lesions. Furthermore, premature CAD patients had a lower all-cause mortality risk (adj.HR: 0.23, 95%-CI: 0.10-0.52; p < 0.001), but target vessel revascularization (adj.HR: 1.63, 95%-CI: 1.18-2.26; p = 0.003) and definite stent thrombosis risks (adj.HR: 2.24, 95%-CI: 1.06-4.72; p = 0.034) were higher. MACE rates showed no statistically significant difference (6.6% vs. 9.4%; adj.HR: 0.86, 95%-CI: 0.65-1.16; p = 0.33). Conclusions: About one out of seven PCI patients was treated for premature CAD. These patients had less complex risk profiles than patients with non-premature CAD; yet, their risk of repeated revascularization and stent thrombosis was higher. As lifetime event risk of patients with premature CAD is known to be particularly high, further efforts should be made to improve modifiable risk factors such as smoking and overweight. TWENTE trials: (TWENTE I, clinicaltrials.gov: NCT01066650), DUTCH PEERS (TWENTE II, NCT01331707), BIO-RESORT (TWENTE III, NCT01674803), and BIONYX (TWENTE IV, NCT02508714).

15.
J Am Heart Assoc ; 11(22): e026041, 2022 11 15.
Article in English | MEDLINE | ID: mdl-36346050

ABSTRACT

Background In a previous trial, higher 5-year mortality was observed following treatment with biodegradable polymer Orsiro sirolimus-eluting stents (SES). We assessed 5-year safety and efficacy of all-comers as well as patients with diabetes treated with SES or Synergy everolimus-eluting stents (EES) versus durable polymer Resolute Integrity zotarolimus-eluting stents (ZES). Methods and Results The randomized BIO-RESORT (Comparison of Biodegradable Polymer and Durable Polymer Drug-Eluting Stents in an All Comers Population) trial enrolled 3514 all-comer patients at 4 Dutch cardiac centers. Patients aged ≥18 years who required percutaneous coronary intervention were eligible. Participants were stratified for diabetes and randomized to treatment with SES, EES, or ZES (1:1:1). The main end point was target vessel failure (cardiac mortality, target vessel myocardial infarction, or target vessel revascularization). Five-year follow-up was available in 3183 of 3514 (90.6%) patients. The main end point target vessel failure occurred in 142 of 1169 (12.7%) patients treated with SES, 130 of 1172 (11.6%) treated with EES, versus 157 of 1173 (14.1%) treated with ZES (hazard ratio [HR], 0.89 [95% CI, 0.71-1.12], Plog-rank=0.31; and HR, 0.82 [95% CI, 0.65-1.04], Plog-rank=0.10, respectively). Individual components of target vessel failure showed no significant between-stent difference. Very late definite stent thrombosis rates were low and similar (SES, 1.1%; EES, 0.6%; ZES, 0.9%). In patients with diabetes, target vessel failure did not differ significantly between stent-groups (SES, 19.8%; EES, 19.2%; versus ZES, 21.1% [Plog-rank=0.69 and Plog-rank=0.63]). Conclusions Orsiro SES, Synergy EES, and Resolute Integrity ZES showed similar 5-year outcomes of safety and efficacy, including mortality. A prespecified stent comparison in patients with diabetes also revealed no significant differences in 5-year clinical outcomes. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT01674803.


Subject(s)
Coronary Artery Disease , Diabetes Mellitus , Drug-Eluting Stents , Percutaneous Coronary Intervention , Humans , Adolescent , Adult , Prosthesis Design , Treatment Outcome , Everolimus , Percutaneous Coronary Intervention/adverse effects , Polymers , Diabetes Mellitus/etiology , Coronary Artery Disease/surgery , Coronary Artery Disease/etiology
16.
Eur J Echocardiogr ; 12(4): 313-21, 2011 Apr.
Article in English | MEDLINE | ID: mdl-21421584

ABSTRACT

This manuscript reviews the use of serial intravascular ultrasound (IVUS) examination of coronary atherosclerosis in recent observational studies and randomized trials that revealed the effects of cholesterol-lowering and lipid-modifying therapies and offered novel insight into plaque progression and regression. We discuss the value of plaque progression-regression as complementary imaging endpoint and potential surrogate marker of cardiovascular event risk. In addition, the progress in serial assessment of coronary plaque composition and plaque vulnerability by radiofrequency-based analyses is reviewed. Finally, we report on the evaluation of true vessel remodelling in recent serial IVUS trials and discuss the future perspective of serial invasive imaging of coronary atherosclerosis.


Subject(s)
Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/drug therapy , Plaque, Atherosclerotic/diagnostic imaging , Plaque, Atherosclerotic/drug therapy , Ultrasonography, Interventional/methods , Anticholesteremic Agents/therapeutic use , Clinical Trials as Topic , Coronary Artery Disease/pathology , Disease Progression , Humans , Hydroxymethylglutaryl-CoA Reductase Inhibitors/therapeutic use , Plaque, Atherosclerotic/pathology , Risk Assessment
17.
Coron Artery Dis ; 32(1): 51-57, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33278175

ABSTRACT

BACKGROUND: Treatment of a coronary bifurcation lesion is often required in routine clinical practice, but data on the performance of very thin-strut biodegradable polymer drug-eluting stents are scarce. METHODS: Comparison of biodegradable polymer and durable polymer drug-eluting stents in an all comers population (BIO-RESORT) is a prospective, multicenter randomized clinical trial that included 3514 all-comer patients, who were randomized to very thin-strut biodegradable polymer-coated sirolimus- or everolimus-eluting stents, versus thin-strut durable polymer-coated zotarolimus-eluting stents. The approach of bifurcation stenting was left at the operator's discretion, and provisional stenting was generally preferred. This prespecified analysis assessed 3-year clinical outcome of all patients in whom treatment involved at least one bifurcation with a side-branch diameter ≥1.5 mm. RESULTS: Of all BIO-RESORT trial participants, 1236 patients were treated in bifurcation lesions and analyzed. Single- and two-stent techniques were used in 85.8% and 14.2%, respectively. 'True' bifurcation lesions (main vessel and side-branch obstructed) were treated in 31.1%. Three-year follow-up was available in 1200/1236 (97.1%) patients. The main endpoint target vessel failure (composite of cardiac death, target vessel-related myocardial infarction, or target vessel revascularization) occurred in sirolimus-eluting stents in 42/412 (10.3%) and in zotarolimus-eluting stents in 49/409 (12.1%) patients (P-logrank = 0.40). In everolimus-eluting stents, target vessel failure occurred in 40/415 (9.8%) patients (vs. zotarolimus-eluting stents: P-logrank = 0.26). There was no between-stent difference in individual components of target vessel failure. Findings were consistent in patients with single-vessel treatment and patients treated with a single-stent technique. CONCLUSIONS: Three years after stenting all-comers with bifurcation lesions, clinical outcome was similar with the sirolimus-eluting and everolimus-eluting stents versus the zotarolimus-eluting stent.


Subject(s)
Coronary Artery Disease , Coronary Vessels , Drug-Eluting Stents , Everolimus/therapeutic use , Long Term Adverse Effects , Prosthesis Failure , Sirolimus/analogs & derivatives , Biodegradable Plastics/therapeutic use , Coronary Artery Disease/diagnosis , Coronary Artery Disease/surgery , Coronary Vessels/diagnostic imaging , Coronary Vessels/pathology , Drug-Eluting Stents/adverse effects , Drug-Eluting Stents/classification , Equipment Failure Analysis , Female , Humans , Immunosuppressive Agents/therapeutic use , Long Term Adverse Effects/epidemiology , Long Term Adverse Effects/etiology , Long Term Adverse Effects/therapy , Male , Middle Aged , Outcome and Process Assessment, Health Care , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/instrumentation , Percutaneous Coronary Intervention/methods , Prosthesis Failure/adverse effects , Prosthesis Failure/etiology , Sirolimus/therapeutic use
18.
Int J Cardiol ; 325: 37-44, 2021 02 15.
Article in English | MEDLINE | ID: mdl-33148427

ABSTRACT

BACKGROUND: Patients with diabetes have more extensive coronary disease, resulting in higher risks of adverse clinical events following stenting. In all-comer patients, contemporary DES have shown excellent safety and efficacy, but data on diabetic patients are scarce. Separately for the BIO-RESORT and BIONYX trials, we assessed the 2-year clinical outcomes of diabetic patients, treated with various contemporary drug-eluting stents (DES). METHODS: We performed two prespecified secondary analyses of two randomized DES trials, which both stratified for diabetes. The main endpoint was target vessel failure (TVF), a composite of cardiac death, target vessel myocardial infarction, or target vessel revascularization. Follow-up was finished before the COVID-19 pandemic. RESULTS: In BIO-RESORT, 624/3514 (17.8%) had diabetes: 211 received Orsiro sirolimus-eluting stents (SES), 203 Synergy everolimus-eluting stents (EES), and 210 Resolute Integrity zotarolimus-eluting stents (RI-ZES). TVF did not differ between SES (10.2%) and EES (10.0%) versus RI-ZES (12.7%) (SES vs. RI-ZES HR:0.78, 95%-CI [0.44-1.40]; p = 0.40, EES vs. RI-ZES HR:0.79, 95%-CI [0.44-1.40]; p = 0.42). In BIONYX, 510/2488 (20.5%) patients had diabetes: 250 received SES and 260 Resolute Onyx zotarolimus-eluting stents (RO-ZES). There was no difference in TVF between SES (10.7%) versus RO-ZES (12.2%) (HR:0.88, 95%-CI [0.52-1.48]; p = 0.63). CONCLUSIONS: There was no difference in 2-year clinical outcome among patients with diabetes, who were treated with SES, or EES, versus RI-ZES. In addition there was no difference in clinical outcome in diabetic patients, who were treated with SES versus RO-ZES. These findings may be considered as a signal of safety and efficacy of the studied DES in patients with diabetes.


Subject(s)
Diabetes Mellitus/drug therapy , Drug-Eluting Stents , Everolimus/administration & dosage , Sirolimus/analogs & derivatives , Biodegradable Plastics , Humans , Multicenter Studies as Topic , Prosthesis Design , Randomized Controlled Trials as Topic , Research Design , Sirolimus/administration & dosage
19.
JACC Cardiovasc Interv ; 13(9): 1100-1109, 2020 05 11.
Article in English | MEDLINE | ID: mdl-32381186

ABSTRACT

OBJECTIVES: The aim of this study was to assess 2-year safety and efficacy of the current-generation thin composite-wire-strut durable-polymer Resolute Onyx zotarolimus-eluting stent (ZES), compared with the ultrathin-strut biodegradable-polymer Orsiro sirolimus-eluting stent (SES) in all-comers and a pre-specified small-vessel subgroup analysis. BACKGROUND: The Resolute Onyx ZES is widely used in clinical practice, but no follow-up data beyond 1 year have been published. The randomized BIONYX (Bioresorbable Polymer-Coated Orsiro Versus Durable Polymer-Coated Resolute Onyx Stents) trial (NCT02508714) established the noninferiority of ZES versus SES regarding target vessel failure (TVF) rates. METHODS: A total of 2,488 all-comer patients were treated at 7 coronary intervention centers in Belgium, Israel, and the Netherlands. The main endpoint, TVF, was a composite of safety (cardiac death or target vessel-related myocardial infarction) and efficacy (clinically indicated target vessel revascularization). Two-year follow-up data were analyzed using Kaplan-Meier methods. RESULTS: Two-year follow-up data were available for 2,460 of 2,488 patients (98.9%). TVF occurred in 93 of 1,243 patients (7.6%) assigned to ZES versus 87 of 1,245 patients (7.1%) assigned to SES (log-rank p = 0.66). There was no significant between-stent difference in individual components of this endpoint. The incidence of definite-or-probable stent thrombosis was low for both treatment arms (0.4% vs. 1.1%; log-rank p = 0.057). In patients stented in small vessels, there was no between-stent difference (TVF 8.2% vs. 8.7% [log-rank p = 0.75], target lesion revascularization 4.0% vs. 4.4% [log-rank p = 0.77]). CONCLUSIONS: At 2-year follow-up, the novel thin composite-wire-strut durable-polymer Resolute Onyx ZES showed in all-comers similar safety and efficacy compared with the ultrathin cobalt-chromium-strut biodegradable-polymer Orsiro SES. The analysis of patients who were treated in small vessels also suggested no advantage for either stent.


Subject(s)
Cardiovascular Agents/administration & dosage , Coronary Artery Disease/therapy , Drug-Eluting Stents , Percutaneous Coronary Intervention/instrumentation , Sirolimus/analogs & derivatives , Aged , Belgium , Cardiovascular Agents/adverse effects , Coronary Artery Disease/diagnostic imaging , Coronary Thrombosis/etiology , Female , Humans , Israel , Male , Middle Aged , Netherlands , Percutaneous Coronary Intervention/adverse effects , Prospective Studies , Prosthesis Design , Sirolimus/administration & dosage , Sirolimus/adverse effects , Time Factors , Treatment Outcome
20.
JACC Cardiovasc Interv ; 12(17): 1650-1660, 2019 09 09.
Article in English | MEDLINE | ID: mdl-31422087

ABSTRACT

OBJECTIVES: The aim of this study was to assess the 3-year safety and efficacy of treating all-comer patients with 3 contemporary drug-eluting stents (DES). BACKGROUND: The BIO-RESORT (Comparison of Biodegradable Polymer and Durable Polymer Drug-Eluting Stents in an All Comers Population) (TWENTE III) randomized trial (NCT01674803) found similar 1-year safety and efficacy for the 2 biodegradable-polymer DES (i.e., ultrathin-strut cobalt-chromium Orsiro sirolimus-eluting stent [SES] and very-thin-strut platinum-chromium Synergy everolimus-eluting stent) compared with the durable-polymer thin-strut cobalt-chromium Resolute Integrity zotarolimus-eluting stent (ZES). Two-year follow-up suggested that the SES might reduce repeat revascularizations beyond 1 year compared with the ZES. METHODS: A total of 3,514 all-comer patients were treated at 4 centers for coronary intervention. The main clinical endpoint, target vessel failure, was a composite of safety (cardiac death or target vessel-related myocardial infarction) and efficacy (target vessel revascularization). Secondary endpoints included the individual components of target vessel failure and stent thrombosis. RESULTS: Three-year follow-up data were available for 3,393 of 3,514 patients (96.6%). Target vessel failure occurred in 8.5% with SES and 10.0% with ZES (plog rank = 0.22) and in 8.8% with everolimus-eluting stents (vs. ZES, plog rank = 0.32). Rates of cardiac death, target vessel myocardial infarction, and target vessel revascularization were similar between stent groups. Landmark analyses found no statistically significant between-stent difference in repeat revascularization between 1 and 3 years. Definite or probable stent thrombosis rates were low (SES, 1.1%; everolimus-eluting stent, 1.1%; ZES, 0.9%) and similar with all 3 DES. CONCLUSIONS: Despite substantial differences in stent backbone and polymer coating, all 3 DES showed favorable 3-year safety and efficacy in all comers, without significant between-stent differences. Further follow-up is required to definitely answer the question of whether one stent might improve clinical outcomes at a later stage.


Subject(s)
Absorbable Implants , Cardiovascular Agents/administration & dosage , Coronary Artery Disease/therapy , Drug-Eluting Stents , Everolimus/administration & dosage , Percutaneous Coronary Intervention/instrumentation , Polymers/chemistry , Sirolimus/analogs & derivatives , Aged , Cardiovascular Agents/adverse effects , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Coronary Thrombosis/etiology , Everolimus/adverse effects , Female , Humans , Male , Middle Aged , Netherlands , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Prosthesis Design , Risk Factors , Sirolimus/administration & dosage , Sirolimus/adverse effects , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL