1.
J Arthroplasty ; 33(10): 3320-3324, 2018 10.
Article in English | MEDLINE | ID: mdl-29970327

ABSTRACT

BACKGROUND: Cross-linked polyethylene (XLPE) has generally low rates of wear and osteolysis at 10 years, but component position may become important with longer follow-up. At 5-13 years, neither acetabular component lateral opening angle nor version were significantly correlated to wear. In the present study, we analyzed the effects of femoral anteversion and combined anteversion on XLPE wear. METHODS: Forty-two well-functioning primary total hip arthroplasties in 36 patients, performed by a single surgeon via a posterior approach, were followed for a minimum of 5 years (mean, 7.1 years; range, 5.0-10.3). All hips had a modular, XLPE liner with a ≥36-mm bearing. Femoral anteversion was measured on the modified Budin view. Wear was measured on radiographs using a validated, computer-assisted, edge-detection-based algorithm. The mean lateral opening angle was 40.4° (range, 22.6°-50.3°). The mean acetabular version was 19.1° (range, 11.3°-27.5°). Neither of these variables was significantly correlated to wear. Effects of femoral anteversion and combined anteversion on XLPE wear were assessed using linear and polynomial regression analysis. RESULTS: Femoral anteversion (mean, 18.4°; range, 6.8°-30.7°) was significantly correlated to linear wear (mean, 0.06 mm/y; range, 0-0.16), showing an inverse parabolic relationship with the least wear occurring at 18.2° (P = .02). Combined anteversion (mean, 37.2°; range, 21.8°-54.3°) showed a similar significant relationship with the least wear at 38.1° (P < .001). Based on regression, combined anteversion between 24.6° and 50.4° resulted in linear wear rates less than 0.1 mm/y. CONCLUSION: To the authors' knowledge, this is the first study to identify femoral anteversion as an independent factor influencing XLPE wear, with least wear occurring around 18°. At 5-10 years, average linear wear of XLPE is below 0.1 mm/y over a 25°-50° range of combined anteversion, with the least wear around 38°. Femoral-acetabular mating is a product of both components. Femoral component version and combined anteversion had a greater effect on wear than acetabular component lateral opening angle. Additional studies are warranted, but these results indicate that the sensitivity of wear studies is increased with version assessments.


Subject(s)
Arthroplasty, Replacement, Hip/instrumentation , Bone Anteversion/complications , Hip Prosthesis , Polyethylene , Prosthesis Failure/etiology , Acetabulum/surgery , Adult , Aged , Aged, 80 and over , Female , Femur/surgery , Humans , Male , Middle Aged , Prosthesis Design , Radiography , Retrospective Studies
2.
J Arthroplasty ; 32(4): 1381-1386, 2017 04.
Article in English | MEDLINE | ID: mdl-28007372

ABSTRACT

BACKGROUND: Cross-linked polyethylene (XLPE) has demonstrated significantly reduced wear and osteolysis into the second decade for total hip arthroplasty. There is a relative paucity of data with ≥36-mm bearings. Issues include potential effects of reduced liner thickness and component position on wear, osteolysis, and mechanical failure of the bearing. METHODS: Radiographs of 48 primary total hip arthroplasties with ≥36-mm modular XLPE bearings were analyzed at a minimum 5 years postoperative on serial radiographs using a validated, edge-detection-based algorithm. Subgroups were examined to assess the effect of bearing diameter, liner thickness, acetabular abduction angle, and acetabular anteversion on XLPE wear. RESULTS: There was no significant difference in volumetric wear when subgroups were stratified by component factors: liner thickness (<6.5 mm vs ≥6.5 mm) 40.69 mm3/y vs 24.47 mm3/y, respectively (P = .315); acetabular component abduction angle (<45° vs ≥45°): 38.68 mm3/y vs 27.8 mm3/y, respectively (P = .522); acetabular anteversion (<20° vs ≥20°): 41.32 mm3/y vs 31.79 mm3/y, respectively (P = .521). There were no dislocations, mechanical failures, or revisions. There were 7 hips with volumetric wear rates ≥80 mm3/y; 1 had possible osteolysis. CONCLUSION: Larger-diameter XLPE wear was not measurably affected by liner thickness, acetabular abduction angle, or acetabular anteversion. However, there is a trend for increasing volumetric wear with increasing bearing size. Wear outliers do occur, and continued follow-up of larger-diameter XLPE bearings is warranted.


Subject(s)
Hip Prosthesis/statistics & numerical data , Osteolysis/etiology , Acetabulum , Adult , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip/instrumentation , Bone Diseases , Cartilage Diseases , Female , Follow-Up Studies , Hip Prosthesis/adverse effects , Humans , Male , Middle Aged , Polyethylene , Prosthesis Design , Prosthesis Failure , Radiography
3.
J Transl Med ; 9: 43, 2011 Apr 19.
Article in English | MEDLINE | ID: mdl-21504557

ABSTRACT

BACKGROUND: The lack of sufficient specificity and sensitivity among conventional cancer biomarkers, such as prostate specific antigen (PSA) for prostate cancer has been widely recognized after several decades of clinical implications. Autoantibodies (autoAb) among others are being extensively investigated as potential substitute markers, but remain elusive. One major obstacle is the lack of a sensitive and multiplex approach for quantifying autoAb against a large panel of clinically relevant tumor-associated antigens (TAA). METHODS: To circumvent preparation of phage lysates and purification of recombinant proteins, we identified B cell epitopes from a number of previously defined prostate cancer-associated antigens (PCAA). Peptide epitopes from cancer/testis antigen NY-ESO-1, XAGE-1b, SSX-2,4, as well as prostate cancer overexpressed antigen AMACR, p90 autoantigen, and LEDGF were then conjugated with seroMAP microspheres to allow multiplex measurement of autoAb present in serum samples. Moreover, simultaneous quantification of autoAb plus total PSA was achieved in one reaction, and termed the "A+PSA" assay. RESULTS: Peptide epitopes from the above 6 PCAA were identified and confirmed that autoAb against these peptide epitopes reacted specifically with the full-length protein. A pilot study was conducted with the A+PSA assay using pre-surgery sera from 131 biopsy-confirmed prostate cancer patients and 121 benign prostatic hyperplasia and/or prostatitis patients. A logistic regression-based A+PSA index was found to enhance sensitivities and specificities over PSA alone in distinguishing prostate cancer from nonmalignant cases. The A+PSA index also reduced false positive rate and improved the area under a receiver operating characteristic curve. CONCLUSIONS: The A+PSA assay represents a novel platform that integrates autoAb signatures with a conventional cancer biomarker, which may aid in the diagnosis and prognosis of prostate cancer and others.


Subject(s)
Autoantibodies/immunology , Immunoassay/methods , Prostate-Specific Antigen/immunology , Prostatic Neoplasms/diagnosis , Prostatic Neoplasms/immunology , Aged , Aged, 80 and over , Antigens, Neoplasm/immunology , Blotting, Western , Diagnosis, Differential , Enzyme-Linked Immunosorbent Assay , Epitopes, B-Lymphocyte/immunology , Humans , Male , Microspheres , Middle Aged , Peptides/immunology , Prostatic Hyperplasia/diagnosis , Prostatic Hyperplasia/immunology , Prostatic Neoplasms/classification , Prostatitis/diagnosis , Prostatitis/immunology , ROC Curve , Reproducibility of Results , Sensitivity and Specificity