Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 124
Filter
1.
N Engl J Med ; 380(5): 437-446, 2019 01 31.
Article in English | MEDLINE | ID: mdl-30699314

ABSTRACT

BACKGROUND: Multiple arterial grafts may result in longer survival than single arterial grafts after coronary-artery bypass grafting (CABG) surgery. We evaluated the use of bilateral internal-thoracic-artery grafts for CABG. METHODS: We randomly assigned patients scheduled for CABG to undergo bilateral or single internal-thoracic-artery grafting. Additional arterial or vein grafts were used as indicated. The primary outcome was death from any cause at 10 years. The composite of death from any cause, myocardial infarction, or stroke was a secondary outcome. RESULTS: A total of 1548 patients were randomly assigned to undergo bilateral internal-thoracic-artery grafting (the bilateral-graft group) and 1554 to undergo single internal-thoracic-artery grafting (the single-graft group). In the bilateral-graft group, 13.9% of the patients received only a single internal-thoracic-artery graft, and in the single-graft group, 21.8% of the patients also received a radial-artery graft. Vital status was not known for 2.3% of the patients at 10 years. In the intention-to-treat analysis at 10 years, there were 315 deaths (20.3% of the patients) in the bilateral-graft group and 329 deaths (21.2%) in the single-graft group (hazard ratio, 0.96; 95% confidence interval [CI], 0.82 to 1.12; P=0.62). Regarding the composite outcome of death, myocardial infarction, or stroke, there were 385 patients (24.9%) with an event in the bilateral-graft group and 425 patients (27.3%) with an event in the single-graft group (hazard ratio, 0.90; 95% CI, 0.79 to 1.03). CONCLUSIONS: Among patients who were scheduled for CABG and had been randomly assigned to undergo bilateral or single internal-thoracic-artery grafting, there was no significant between-group difference in the rate of death from any cause at 10 years in the intention-to-treat analysis. Further studies are needed to determine whether multiple arterial grafts provide better outcomes than a single internal-thoracic-artery graft. (Funded by the British Heath Foundation and others; Current Controlled Trials number, ISRCTN46552265 .).


Subject(s)
Coronary Artery Bypass/methods , Coronary Artery Disease/surgery , Mammary Arteries/transplantation , Aged , Cause of Death , Coronary Artery Disease/mortality , Female , Follow-Up Studies , Humans , Intention to Treat Analysis , Male , Middle Aged , Myocardial Infarction/epidemiology , Stroke/epidemiology , Survival Analysis
2.
BMC Cardiovasc Disord ; 22(1): 108, 2022 03 17.
Article in English | MEDLINE | ID: mdl-35296256

ABSTRACT

BACKGROUND: Although cardioplegia is used since the '70s of the last century, debate on cardioprotection during cardio-surgical procedures is still actual. The selection of a particular method depends mainly on the preferences and experience of a specific center or even surgeon. Crystalloid cardioplegia is an aqueous ion solution similar to intracellular (Custodiol HTK) or extracellular (Plegisol) fluid. The potensional clinical advantages of relatively new idea of cardioplegia solution based on intracellular composition (Custodiol HTK) justifies futher research, but only a few used cultured cells in laboratory conditions. METHODS: In this study, the authors sought to compare Custodiol HTK with Plegisol cardioplegia solutions using an in-vitro model simulating cardioplegic arrest. The efficacy of myocardial protection during ischemia was investigated with susceptible indicators like the appearance of the deleterious effect of reactive oxygen species and oxidative stress markers. Immersed human cardiomyocytes and rat cardiomyoblasts H9C2 in cardioplegia for 4 h were examined for expression of oxidative stress markers (MnSOD, iNOS, HSP27), cardioplegic solutions cytotoxicity, and peroxidation damage of the cell's lipids and proteins. All tests were performed after 0.5 h, 1 h, 2 h, and 4 h of incubation in identical physical and biological conditions, which is difficult to achieve in clinical trials. RESULTS: The lower cytotoxicity index performed on matured cells of human cardiomyocytes and highest dehydrogenase level showed after incubation with Custodiol HTK. This did not apply to tests on immature cells H9C2. Custodiol HTK induced significantly stronger iNOS expression. The decrease of HSP27 concentration has been instantaneous and maintained troughout the study only in both cultures incubated with Custodiol HTK. The other tests: lipid peroxidation, carbonyl groups concentration and MnSOD expression show no clear superiority evidence of used cardioplegic solutions. CONCLUSIONS: Considering proceeded examinations on cultured cardiomyocytes, Custodiol HTK appears to be safer than Plegisol.


Subject(s)
Cardioplegic Solutions , Myocytes, Cardiac , Animals , Bicarbonates , Calcium Chloride , Cardioplegic Solutions/therapeutic use , Cardioplegic Solutions/toxicity , Glucose/pharmacology , Glucose/therapeutic use , HSP27 Heat-Shock Proteins , Heart Arrest, Induced/adverse effects , Humans , Magnesium , Potassium Chloride , Rats , Retrospective Studies , Sodium Chloride
3.
J Card Surg ; 37(3): 526-531, 2022 Mar.
Article in English | MEDLINE | ID: mdl-34821415

ABSTRACT

BACKGROUND: The incompetent bicuspid aortic valve (BAV) can be repaired using various techniques. This study presents a prospective comparison of external and subcommissural aortic annuloplasty. METHODS: Fifty consecutive patients (38 males, age: 43.9 ± 15.8 years) with BAV insufficiency with or without aortic dilatation underwent valve repair in a single institution. They were prospectively allocated to one of two groups based on the aortic annulus stabilization technique: 25 patients were operated on using the subcommissural annuloplasty (SCA) and 25 using the external complete annuloplasty (EA). Transthoracic echocardiography was performed in all patients before the operation and 1 and 3 years after the operation. Moreover, mortality and morbidity at 7 years were evaluated. RESULTS: In prospective echocardiographic comparison, EA was associated with smaller diameter of the aortic annulus (24.1 ± 2.6 mm vs. 25.8±2.1 mm, p < .05) and lower mean and peak transvalvular gradients (7 ± 4 mmHg vs. 13 ± 4 mmHg, p = .02 and 15.3 ± 9.7 mmHg vs. 20.7 ± 5.6 mmHg, p = .03, respectively). No patients died or required reoperation due to recurrent insufficiency at 6,81 (interquartile range-0,17) years after the operation. The Kaplan-Meier actuarial freedom from aortic regurgitation (AR) grade =2 or gradient > 20 mmHg at 35.1 ± 3.6 months years was 96% (24 out of 25) for patients who had external annuloplasty and amounted to 76% (19 out of 25) for those who had SCA, p = .05). CONCLUSIONS: External annuloplasty performed during repair of the BAV is associated with better hemodynamics at medium-term follow-up compared to SCA.


Subject(s)
Aortic Valve Insufficiency , Bicuspid Aortic Valve Disease , Cardiac Valve Annuloplasty , Adult , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/surgery , Echocardiography , Female , Humans , Male , Middle Aged , Prospective Studies , Retrospective Studies , Treatment Outcome
4.
Sensors (Basel) ; 22(14)2022 Jul 13.
Article in English | MEDLINE | ID: mdl-35890918

ABSTRACT

Over the last couple of years, Blockchain technology has emerged as a game-changer for various industry domains, ranging from FinTech and the supply chain to healthcare and education, thereby enabling them to meet the competitive market demands and end-user requirements. Blockchain technology gained its popularity after the massive success of Bitcoin, of which it constitutes the backbone technology. While blockchain is still emerging and finding its foothold across domains, Cloud computing is comparatively well defined and established. Organizations such as Amazon, IBM, Google, and Microsoft have extensively invested in Cloud and continue to provide a plethora of related services to a wide range of customers. The pay-per-use policy and easy access to resources are some of the biggest advantages of Cloud, but it continues to face challenges like data security, compliance, interoperability, and data management. In this article, we present the advantages of integrating Cloud and blockchain technology along with applications of Blockchain-as-a-Service. The article presents itself with a detailed survey illustrating recent works combining the amalgamation of both technologies. The survey also talks about blockchain-cloud services being offered by existing Cloud Service providers.


Subject(s)
Blockchain , Cloud Computing , Computer Security , Data Management , Technology
5.
BMC Cardiovasc Disord ; 21(1): 13, 2021 01 06.
Article in English | MEDLINE | ID: mdl-33407164

ABSTRACT

BACKGROUND: The incompetent bicuspid aortic valve (BAV) can be replaced or repaired using various surgical techniques. This study sought to assess the efficacy of external annuloplasty and postoperative reverse remodelling using cardiac magnetic resonance (CMR) and compare the results of external and subcommissural annuloplasty. METHODS: Out of a total of 200 BAV repair performed between 2004 and 2018, 21 consecutive patients (median age 54 years) with regurgitation requiring valve repair with annuloplasty without concomitant aortic root surgery were prospectively referred for CMR and transthoracic echocardiography (TTE) one year after the operation. Two aortic annulus stabilization techniques were used: external, circumferential annuloplasty (EA), and subcommissural annuloplasty (SCA). RESULTS: 11 patients received EA and 10 patients were treated using SCA. There was no in-hospital mortality and all patients survived the follow-up period (median: 12.6 months (first quartile: 6.6; third quartile: 14.1). CMR showed strong correlation between postoperative aortic recurrent regurgitant fraction and left ventricular end-diastolic volume (r = 0.62; p = 0.003) as well as left ventricular ejection fraction (r = -0.53; p = 0.01). Patients treated with EA as compared with SCA had larger anatomic aortic valve area measured by CMR (3.5 (2.5; 4.0) vs. 2.5 cm2 (2.0; 3.4); p = 0.04). In both EA and SCA group, aortic valve area below 3.5 cm2 correlated with no regurgitation recurrency. EA (vs. SCA) was associated with lower peak transvalvular aortic gradients (10 (6; 17) vs. 21 mmHg (15; 27); p = 0.04). CONCLUSIONS: The repair of the bicuspid aortic valve provides significant postoperative reverse remodelling, provided no recurrent regurgitation and durable reduction annuloplasty can be achieved. EA is associated with lower transvalvular gradients and higher aortic valve area assessed by CMR, compared to SCA.


Subject(s)
Aortic Valve Insufficiency/surgery , Bicuspid Aortic Valve Disease/surgery , Cardiac Valve Annuloplasty , Magnetic Resonance Imaging, Cine , Adult , Aged , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/physiopathology , Bicuspid Aortic Valve Disease/diagnostic imaging , Bicuspid Aortic Valve Disease/physiopathology , Cardiac Valve Annuloplasty/adverse effects , Echocardiography , Female , Hemodynamics , Humans , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Recovery of Function , Time Factors , Treatment Outcome , Ventricular Function, Left , Ventricular Remodeling
6.
Hum Biol ; 93(1): 33-50, 2021.
Article in English | MEDLINE | ID: mdl-35338701

ABSTRACT

The humanitarian crisis on the US-Mexico border is a long-standing and evolving crisis in which nearly 8,000 deaths have been reported in the last two decades. These deaths are largely distributed across the Arizona-Mexico and Texas-Mexico border regions, where demographic trends for immigrants attempting to cross into the United States have shifted dramatically. The demographic change and volume of immigrants seeking shelter in the United States present new challenges for the forensic practitioners entrusted with the identification of individuals who lose their lives during the final segment of their journey. Within this border context, this study investigated how genetic variation inferred from forensically significant microsatellites can provide valuable information on regions of origin for unidentified remains at the group level. To explore how to mobilize these genetic data to inform identification strategies, the authors conducted a comparative genetic analysis of identified and unidentified immigrant cases from the Arizona- and Texas-Mexico contexts, as well as 27 other Latin American groups. Allele frequencies were utilized to calculate FST, and relationships were visually depicted in a multidimensional scaling plot. A Spearman correlation coefficient analysis assessed the strength and significance of population relationships, and an agglomerative clustering analysis assessed population clusters. Results indicate that Arizona-Mexico immigrants have the strongest relationship (>80%) with groups from El Salvador, Guatemala, Mexico, and an indigenous group from southern Mexico. Texas-Mexico immigrants have the strongest relationships (>80%) with groups from Belize, Colombia, Costa Rica, El Salvador, Guatemala, Honduras, and Nicaragua. These findings agree with, and are discussed in comparison with, previously reported demographic trends, population genetics research, and population history analyses. The authors emphasize the utility and necessity of coupling genetic variation research with a nuanced anthropological perspective for identification processes in the US-Mexico border context.


Subject(s)
Emigrants and Immigrants , Genetics, Population , Hispanic or Latino , Arizona , Genetic Variation , Hispanic or Latino/genetics , Humans , Latin America , Mexico , Texas , United States
7.
BMC Cardiovasc Disord ; 19(1): 292, 2019 12 13.
Article in English | MEDLINE | ID: mdl-31835993

ABSTRACT

BACKGROUND: Recent scientific reports have brought into light a new concept of goal-directed perfusion (GDP) that aims to recreate physiological conditions in which the risk of end-organ malperfusion is minimalized. The aim of our study was to analyse patients' interim physiology while on cardiopulmonary bypass based on the haemodynamic and tissue oxygen delivery measurements. We also aimed to create a universal formula that may help in further implementation of the GDP concept. METHODS: We retrospectively analysed patients operated on at the Wroclaw University Hospital between June 2017 and December 2018. Since our observations provided an extensive amount of data, including the patients' demographics, surgery details and the perfusion-related data, the Data Science methodology was applied. RESULTS: A total of 272 (mean age 62.5 ± 12.4, 74% male) cardiac surgery patients were included in the study. To study the relationship between haemodynamic and tissue oxygen parameters, the data for three different values of DO2i (280 ml/min/m2, 330 ml/min/m2 and 380 ml/min/m2), were evaluated. Each set of those lines showed a descending function of CI in Hb concentration for the set DO2i. CONCLUSIONS: Modern calculation tools make it possible to create a common data platform from a very large database. Using that methodology we created models of haemodynamic compounds describing tissue oxygen delivery. The obtained unique patterns may both allow the adaptation of the flow in relation to the patient's unique morphology that changes in time and contribute to wider and safer implementation of perfusion strategy which has been tailored to every patient's individual needs.


Subject(s)
Cardiac Surgical Procedures , Cardiopulmonary Bypass , Data Science , Models, Cardiovascular , Oxygen/blood , Aged , Biomarkers/blood , Cardiac Surgical Procedures/adverse effects , Cardiopulmonary Bypass/adverse effects , Cardiopulmonary Bypass/instrumentation , Female , Heart-Lung Machine , Hemodynamics , Hemoglobins/metabolism , Humans , Male , Middle Aged , Retrospective Studies , Treatment Outcome
8.
BMC Cardiovasc Disord ; 19(1): 294, 2019 12 16.
Article in English | MEDLINE | ID: mdl-31842758

ABSTRACT

BACKGROUND: Postoperative atrial fibrillation occurs in up to 30% of patients after coronary artery bypass graft (CABG) and its cause is unknown. The aim of the study was to evaluate whether concentration of resistin in surrounding coronary artery perivascular adipose tissue (PVAT) is related to postoperative atrial fibrillation occurrence. METHODS: A total number of 46 patients (35 male, 11 female; median age 66.5) were qualified for elective CABG. Medical history, laboratory test results and echocardiographic parameters were noted. Patients were monitored up to 3 days after CABG and then were divided into groups with and without postoperative atrial fibrillation occurrence. Fragments of PVAT were collected intra-operatively: near the left anterior descending artery and main left coronary artery. The concentration of resistin was determined by Human Resistin Quantikine ELISA Kit and expressed as ng/g. A multivariate stepwise logistic regression analysis was performed to find variables related to postoperative atrial fibrillation occurrence. RESULTS: Postoperative atrial fibrillation occurred in 14 (30.4%) patients. The patients with and without postoperative atrial fibrillation were similar in age, gender, epicardial adipose tissue thickness and laboratory parameters. The concentration of resistin in PVAT near the left main coronary artery was significantly higher in patients with postoperative atrial fibrillation than in those without the complication (P = 0.03). In the multivariate stepwise logistic regression analysis the concentration of resistin above cut-off point 54 ng/g in PVAT near left main coronary artery was independently related to postoperative atrial fibrillation occurrence (OR: 7.7; 95% CI:1.4-42.2 p = 0.02). CONCLUSIONS: The higher concentrations of resistin in PVAT near the left main coronary artery which is located close to the left atrium are associated with postoperative atrial fibrillation.


Subject(s)
Adipose Tissue/metabolism , Atrial Fibrillation/etiology , Coronary Artery Bypass/adverse effects , Resistin/metabolism , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/metabolism , Female , Humans , Male , Middle Aged , Risk Factors , Treatment Outcome , Up-Regulation
9.
BMC Cardiovasc Disord ; 19(1): 189, 2019 08 05.
Article in English | MEDLINE | ID: mdl-31382900

ABSTRACT

BACKGROUND: Coronary artery bypass graft (CABG) surgery is an effective therapeutic strategy for coronary heart disease (CHD). Myocardial longitudinal strain echocardiography with 2D speckle tracking could obtain ventricular function with better accuracy and reliability than the left ventricular ejection fraction. The aim of the study was to assess changes in left ventricular function in patients before and after surgical revascularization for a 24-month period of observation, using echocardiography with speckle tracking strain imaging. We searched for echocardiographic predictors of poor early and long-term outcome after CABG. METHODS: We enrolled 69 patients scheduled for elective coronary bypass grafting. Patients were divided into groups based on pre-operative systolic and diastolic parameters, depending on the GLS value and the E' Lat and E/E' value. The correlation between these parameters and early and long-term outcomes was analyzed. RESULTS: Preoperative EF was preserved in 86, 95% (60) patients. Pre-operative reduced GLS was observed in 73.91% (51) of patients and severely reduced in 31.88% (22). In the first post-operative 6-month period, we observed a significant decrease in the GLS. The GLS was a predictor of early postoperative outcome for intubation time, the inotropes use and length of ICU stay. Diastolic dysfunction was a predictor of the greater inotrope requirements. CONCLUSIONS: Global longitudinal strain and diastolic dysfunction parameters are a good predictors of worse early outcome after CABG.


Subject(s)
Coronary Artery Bypass , Coronary Artery Disease/surgery , Echocardiography, Doppler, Pulsed , Postoperative Complications/diagnostic imaging , Stroke Volume , Ventricular Function, Left , Aged , Cardiotonic Agents/therapeutic use , Coronary Artery Bypass/adverse effects , Coronary Artery Bypass/mortality , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Coronary Artery Disease/physiopathology , Female , Humans , Male , Middle Aged , Postoperative Complications/physiopathology , Postoperative Complications/therapy , Predictive Value of Tests , Progression-Free Survival , Prospective Studies , Recovery of Function , Risk Factors , Stroke Volume/drug effects , Time Factors , Ventricular Function, Left/drug effects
10.
J Cardiothorac Vasc Anesth ; 33(11): 2930-2937, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31281012

ABSTRACT

OBJECTIVES: To assess the reliability of EuroSCORE II in an entire population after isolated coronary artery surgery and separately among patients who underwent redo surgery due to bleeding, and to create a model predicting hospital death among patients who underwent redo surgery owing to bleeding. DESIGN: Retrospective study based on data from the Polish National Registry of Cardiac Surgical Procedures. SETTING: Multi-institutional study. PARTICIPANTS: The study comprised 41,353 patients who underwent isolated coronary artery surgery in Poland between January 2012 and December 2014. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: EuroSCORE II reliability was estimated using the area under the receiver operating characteristics curve (AUC), the observed-to-expected surgical mortality ratio (O/E), and the Hosmer-Lemeshow test. Parameters of the function correcting the original EuroSCORE II were determined using the least squares method. The original score was adjusted using a created formula. Among the 41,353 patients, 1,406 (3.4%) underwent reexploration. Even though EuroSCORE II was reliable in predicting hospital mortality in the entire population (AUC 0.76, O/E ratio 1.08), it greatly underestimated mortality for patients who required reexploration (AUC 0.74, O/E ratio 4.33). In this subpopulation, the worst performance of the EuroSCORE II was noted among patients with the lowest predicted mortality (0.50%-0.82%) Accurate calibration was obtained by adding a coefficient and creating a nomogram. CONCLUSIONS: EuroSCORE II was reliable in a Polish population undergoing isolated coronary surgery. After redo surgery for bleeding, the observed mortality was much higher than in the overall coronary population, but the rate was made more accurate by adding a coefficient to the initially calculated EuroSCORE II.


Subject(s)
Coronary Artery Bypass/adverse effects , Coronary Artery Disease/surgery , Coronary Vessels/surgery , Postoperative Hemorrhage/diagnosis , Registries , Risk Assessment/methods , Aged , Female , Hospital Mortality/trends , Humans , Male , Poland/epidemiology , Postoperative Hemorrhage/mortality , Prognosis , Reoperation , Retrospective Studies , Risk Factors , Survival Rate/trends
11.
Eur J Vasc Endovasc Surg ; 56(6): 808-816, 2018 Dec.
Article in English | MEDLINE | ID: mdl-30197286

ABSTRACT

OBJECTIVES: Thoracic endovascular aortic repair technology focuses on accurately deploying the stent graft in the proximal landing zone in the proximal to distal direction. The aim of this in vitro study was to evaluate the accuracy of stent graft deployment in the distal landing zone. METHODS: It was hypothesised that a reverse implantation mechanism (in a distal to proximal deployment direction, when the operator starts to open the endoprosthesis from distal to proximal), might enhance landing accuracy in the distal LZ. The aim was to investigate this hypothesis by implanting stent grafts into the 3D printed aortas with the currently available deployment mechanism. Based on two human patients' computed tomography angiography scans, two aortas were 3D printed at 1:1 scale: "straight" and "crooked" aortas with distal aortic tortuosity of 1.006 and 1.078, respectively. They were used in order to test three endoprostheses (E-vita THORACIC 3G, Relay Plus, Valiant Captivia) 10 times by implanting them in three ways: proximal landing in the aneurysm, proximal landing in another stent graft, reverse implantation (via simulated antegrade access). The aim was to land just above the target vessel's upper edge. The distance to the target vessel and wedge apposition were assessed under a direct view using caliper. RESULTS: The distance to the target vessel was 3 mm (IQR 0; 8) if the stent graft landed proximally in aneurysm, 2 mm (IQR 0; 5) if it landed proximally in another stent graft, and 0 mm (IQR 0; 0) when reverse implantation was applied. The distance to the target vessel measuring 5 mm or occurred in 45%, 30%, and 0%, respectively. Overall the median wedge apposition after stent graft implantation was 0 mm (IQR 0; 0) in the "straight" versus 18 mm (IQR 15; 20) in the "crooked" aorta (p < .001). CONCLUSIONS: Reverse stent graft deployment is associated with more accurate landing in the distal landing zone. Distal aortic tortuosity constitutes an important impediment to covering the distal LZ's entire circumference with a stent graft.


Subject(s)
Aorta/surgery , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis , Endovascular Procedures , Aorta/pathology , Blood Vessel Prosthesis Implantation/methods , Computed Tomography Angiography/methods , Endovascular Procedures/methods , Humans , Prosthesis Design , Stents
12.
BMC Cardiovasc Disord ; 18(1): 152, 2018 07 28.
Article in English | MEDLINE | ID: mdl-30055568

ABSTRACT

BACKGROUND: Lipomatous hypertrophy of the atrial septum (LHAS) is an anomaly of the heart. It is characterized by an infiltration of adipocytes into myocytes of the interatrial septum, sparing the fossa ovalis, which gives a characteristic hourglass-shaped image. Due to the progress in imaging techniques, it can be recognized more frequently, but it is still often misdiagnosed. CASE PRESENTATION: We present a case of 65-year-old woman with an incidentally discovered lipomatous hypertrophy of the atrial septum during cardiac surgery, which has caused the technical problems for surgeons with bicaval cannulation and visualization of the operated structures of the heart. Due to the unclear shadow in the lung parenchyma, the patient had preoperative computed tomography (CT) done, but the study report focused only on the lung description, neglecting visible changes in the structure of the heart. Based on the standardly performed intra-operative transesophageal echocardiography (TEE), as well as by analyzing the chest X-ray and CT scans, the diagnosis of LHAS was made. It allowed the surgeon to leave the mass intact, thus not increasing the risk of the baseline surgery. CONCLUSIONS: LHAS is a rare but increasingly recognized anomaly of the heart. Contemporary diagnostic methods allow to diagnose and make the right therapeutic decisions. The utility of TEE and analysis of X-ray images, in this case, allowed the surgeon to recognize LHAS, and because of its histologically benign nature and asymptomatic course, to leave this change intact. Surgical treatment should be limited only to cases of patients with life-threatening cardiovascular complications.


Subject(s)
Cardiomegaly/complications , Heart Septal Defects, Atrial/complications , Heart Valve Prosthesis Implantation , Incidental Findings , Lipomatosis/complications , Mitral Valve Insufficiency/surgery , Aged , Cardiomegaly/diagnostic imaging , Echocardiography, Transesophageal , Female , Heart Septal Defects, Atrial/diagnostic imaging , Heart Valve Prosthesis Implantation/adverse effects , Humans , Lipomatosis/diagnostic imaging , Mitral Valve Insufficiency/complications , Mitral Valve Insufficiency/diagnostic imaging , Predictive Value of Tests , Risk Factors , Tomography, X-Ray Computed
13.
BMC Cardiovasc Disord ; 18(1): 154, 2018 07 31.
Article in English | MEDLINE | ID: mdl-30064358

ABSTRACT

BACKGROUND: The stress in the ascending aorta results from many biomechanical factors including the geometry of the vessel and its maximum dimensions, arterial blood pressure and longitudinal systolic stretching due to heart motion. The stretching of the ascending aorta resulting from the longitudinal displacement of the aortic annulus during the heart cycle has not been examined in the general population so far. The aim of the study is to evaluate this parameter using cardiovascular magnetic resonance (CMR) imaging in the general population in all age groups. METHODS: The cardiac magnetic resonance images of 73 patients were evaluated. The maximum distance to which the ventriculo-aortic junction was pulled by the contracting heart (LDAA - longitudinal displacement of the aortic annulus) was measured in the cine coronal sequences. Moreover, the maximum dimensions of the aortic root and the ascending aorta were assessed. RESULTS: The LDAA value was on average 11.6 ± 2.9 mm (range: 3-19 mm; 95% CI: 10.9-12.3 mm) and did not differ between males and females (11.8 ± 2.9 mm vs. 11.2 ± 2.9 mm, p = .408). The diameter of the ascending aorta was 32 ± 6.3 mm (range: 20-57 mm). The maximal dimension of the aortic root was 35 ± 5.1 mm (range: 18-42 mm). There was a statistically significant negative correlation between the LDAA and the age of patients (r = -.38, p = .001). There was no significant correlation between the LDAA and aortic root dimension (r = .1, p = .409) and between the LDAA and diameter of the ascending aorta (r = .16, p = .170). CONCLUSIONS: Human aortic root and ascending aorta are significantly stretched during systole and the distance to which the aorta is stretched decreases with age. The measurement of the longitudinal displacement of the aortic annulus using the CMR is feasible and reproducible.


Subject(s)
Aorta/diagnostic imaging , Aortic Valve/diagnostic imaging , Hemodynamics , Magnetic Resonance Imaging, Cine , Adult , Aorta/physiopathology , Aortic Valve/physiopathology , Biomechanical Phenomena , Diastole , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Regional Blood Flow , Retrospective Studies , Stress, Mechanical , Systole
14.
BMC Cardiovasc Disord ; 17(1): 297, 2017 12 20.
Article in English | MEDLINE | ID: mdl-29262774

ABSTRACT

BACKGROUND: Biomechanical factors influence stress in the aortic wall. The aim of this study was to assess how the diameter and shape of the vessel, blood pressure and longitudinal systolic aortic stretching (SAS) caused by the contraction of the myocardium influence stress in the aortic wall. METHODS: Three computational models of the non-dilated aorta and aneurysms of the ascending aorta and aortic root were created. Then, finite elements analyses were carried out. The models were subjected to blood pressure (120 mmHg and 160 mmHg) and longitudinal systolic aortic stretching (0 mm, 5 mm, 10 mm and 15 mm). The influence of wall elasticity was examined too. RESULTS: Blood pressure had a smaller impact on the stress than the SAS. An increase in blood pressure from120 mmHg to 160 mmHg increased the peak wall stress (PWS) on average by 0.1 MPa in all models. A 5 mm SAS caused a 0.1­0. 2 MPa increase in PWS in all the models. The increase in PWS caused by a 10mm and 15mmSAS was 0.2 MPa and 0. 4 MPa in the non-dilated aorta, 0.2­0.3 MPa and 0.3­0.5 MPa in the aneurysm of the ascending aorta, and 0.1­0.2 MPa and 0.2­0.3 MPa in the aortic root aneurysm model, respectively. The loss of elasticity of the aneurysmal wall resulted in an increase of PWS by 0.1­0.2 MPa. CONCLUSIONS: Aortic geometry, wall stiffness, blood pressure and SAS have an impact on PWS. However, SAS had the biggest impact on wall stress. The results of this study may be useful in future patient-specific computational models used to assess the risk of aortic complications.


Subject(s)
Aorta/physiopathology , Aortic Aneurysm/physiopathology , Computer Simulation , Finite Element Analysis , Hemodynamics , Models, Cardiovascular , Aorta/pathology , Aortic Aneurysm/etiology , Aortic Aneurysm/pathology , Arterial Pressure , Biomechanical Phenomena , Dilatation, Pathologic , Elastic Modulus , Humans , Regional Blood Flow , Stress, Mechanical , Vascular Stiffness
17.
Catheter Cardiovasc Interv ; 87(3): 478-87, 2016 Feb 15.
Article in English | MEDLINE | ID: mdl-25963541

ABSTRACT

BACKGROUND: Transcatheter paravalvular leak closure (TPVLC) offers a viable alternative to reoperation but optimal technical strategy is still to be defined. We present a prospective TPVLC registry in which safety and efficacy of multi-plug, single-stage approach were assessed. METHODS: Patients with heart failure (HF) symptoms caused by PVL were qualified for TPVLC by Heart Team. Ante- or retrograde access was employed for mitral while retrograde only for aortic PVLs. Two to 4 AVP 3 devices were simultaneously implanted into each PVL. Endpoints were defined according to VARC-2. RESULTS: From 64 referred patients 49, with either mechanical valves (n = 30) or stented bioprostheses, were eligible for TPVLC. PVL location was mitral (n = 29) or aortic (n = 20). In aortic group acute procedural success (APS) ratio was 100% and no MACCEs occurred. In mitral group, first-attempt TPVLC was successful in 22 cases (4/4 in transapical and 18/25 in transseptal access). Second-attempt transapical procedure followed transseptal failure in 5 patients. Mitral TPVLC ultimately proved efficient in 89.7% with 76.5% APS. Cumulatively, TPVLC was accomplished in 46 subjects (93.9%) with 78% APS. When successful, it led to a significant decrease of NT-proBNP concentration and HF symptoms regression. Periprocedural safety endpoints were met in three patients and included non-disabling stroke, and two access site-related complications. In device failure group two patients died (end-stage HF) and two others were rehospitalized. CONCLUSION: TPVLC with simultaneous deployment of multiple AVP III occluders is feasible with high device success rate and no significant periprocedural complications. The clinical benefits of reduction of HF symptoms and hemolysis are evident after 30 days and persist up to 1 year without recurrence of PVL.


Subject(s)
Aortic Valve Insufficiency/therapy , Cardiac Catheterization/instrumentation , Heart Failure/therapy , Heart Valve Diseases/surgery , Heart Valve Prosthesis Implantation/adverse effects , Mitral Valve Insufficiency/therapy , Prosthesis Failure , Vascular Closure Devices , Aged , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/mortality , Aortic Valve Insufficiency/physiopathology , Biomarkers/blood , Bioprosthesis , Cardiac Catheterization/adverse effects , Cardiac Catheterization/mortality , Echocardiography, Doppler, Color , Echocardiography, Three-Dimensional , Echocardiography, Transesophageal , Equipment Design , Female , Heart Failure/diagnostic imaging , Heart Failure/mortality , Heart Failure/physiopathology , Heart Valve Diseases/physiopathology , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/mortality , Hemolysis , Humans , Male , Middle Aged , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/mortality , Mitral Valve Insufficiency/physiopathology , Natriuretic Peptide, Brain/blood , Patient Readmission , Peptide Fragments/blood , Prospective Studies , Registries , Risk Factors , Stents , Time Factors , Treatment Outcome
20.
J Heart Valve Dis ; 23(4): 414-23, 2014 Jul.
Article in English | MEDLINE | ID: mdl-25803967

ABSTRACT

BACKGROUND AND AIM OF THE STUDY: The advantages of aortic valve repair and root reconstruction include the maintenance of natural valve hemodynamics and an avoidance of prosthetic valve-related complications. However, the general acceptance of valve reconstruction currently may be limited by a paucity of long-term follow up data from only a few centers. The study aim was to supplement existing outcome information for aortic valve repair. METHODS: Between 2003 and 2012, a total of 150 consecutive patients (119 males, 31 females; mean age 51.1 years) with significant aortic regurgitation and aortic root enlargement underwent aortic valve repair and associated root reconstruction. The same prospective selection criteria and systematic valve repair approaches were followed throughout the study. Root management consisted of either root remodeling or reimplantation with Dacron prostheses. Kaplan-Meier techniques were used to assess major end-points of all-cause mortality, reoperation, and repair failure. Univariable log-rank testing identified any associations between risk factors and major events. RESULTS: The early mortality rate was 2.7% (n = 4), and early repair failure rate 3.3% (n = 5). At a mean follow up of 43.6 months (1st, 3rd percentile, 17.8, 78.0 months), the survival rate was 93% and freedom from reoperation 91%. Univariable risk factors for mortality included advanced preoperative NYHA class and a requirement for root replacement. Repair failure and reoperation were associated with bicuspid valve anatomy, subcommissural annuloplasty, leaflet resection with pericardial patching, and Gore-Tex leaflet reinforcement. CONCLUSION: The present data, acquired from a prospective cohort of patients undergoing aortic valve repair and root reconstruction, reinforced the satisfactory late results obtained with valve reconstruction. These findings also support a broader application of aortic valve repair in future patients.


Subject(s)
Aorta/surgery , Aortic Valve Insufficiency/surgery , Aortic Valve/surgery , Aorta/diagnostic imaging , Aortic Valve/diagnostic imaging , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/mortality , Blood Vessel Prosthesis Implantation , Cardiac Valve Annuloplasty , Female , Follow-Up Studies , Humans , Male , Middle Aged , Polyethylene Terephthalates , Prospective Studies , Reoperation , Risk Factors , Treatment Outcome , Ultrasonography
SELECTION OF CITATIONS
SEARCH DETAIL