Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters

Database
Language
Publication year range
1.
Rev Sci Instrum ; 92(4): 045106, 2021 Apr 01.
Article in English | MEDLINE | ID: mdl-34243404

ABSTRACT

The effect of rotation on adsorption kinetics of CO2 on activated carbon (AC) is studied using a novel rotation device. The device consists of a rotating cylindrical cell with inner dimensions of 4.5 cm radius and 1 mm height, while it operates at 5000 and 8000 rpm. Various cases of the CO2/AC system are examined under a rotation field: in particular, (a) solid at vacuum, (b) gas without solid, (c) gas/solid at a non-equilibrium state of the adsorption process, and (d) gas/solid near an equilibrium state of the adsorption process. Micro-fragmentation of solid particles is observed at 8000 rpm but not at 5000 rpm; the latter is then chosen as the preferable speed for the rest of the experiments. During rotation of the gas, a well is noticed at the pressure curve, the size of which is in accordance with theoretical predictions of the behavior of a spinning gas. Rotation at an early stage of the adsorption process can suppress the filling time of a rotating storage reservoir to half of its value. Rotation near the equilibrium point reveals an enhanced adsorption capacity of the solid. The physics behind these phenomena are discussed with the aid of N2-adsorption porosimetry and scanning electron microscopy measurements.

2.
Rev Sci Instrum ; 92(12): 124503, 2021 Dec 01.
Article in English | MEDLINE | ID: mdl-34972443

ABSTRACT

We describe an experiment container with light scattering and imaging diagnostics for experiments on soft matter aboard the International Space Station (ISS). The suite of measurement capabilities can be used to study different materials in exchangeable sample cell units. The currently available sample cell units and future possibilities for foams, granular media, and emulsions are presented in addition to an overview of the design and the diagnostics of the experiment container. First results from measurements performed on ground and during the commissioning aboard the ISS highlight the capabilities of the experiment container to study the different materials.

3.
Adv Colloid Interface Sci ; 222: 436-45, 2015 Aug.
Article in English | MEDLINE | ID: mdl-24819725

ABSTRACT

The term liquid bridge refers to the specific silhouette of a liquid volume when it is placed between two solid surfaces. Liquid bridges have been studied extensively both theoretically and experimentally during the last century due to their significance in many technological applications. It is worth noticing that even today new technological applications based on liquid bridges continue to appear. A liquid bridge has a well-defined surface configuration dictated by a rigid theoretical foundation so the potential of its utilization as a tool to study surface properties of liquids is apparent. However, it is very scarce in literature that the use of liquid bridges is suggested as an alternative to the well-established drop techniques (pendant/sessile drop). The present work (i) presents the theoretical background for setting up a liquid-bridge based surface property estimation problem, (ii) describes the required experimental equipment and procedures and (iii) performs a thorough literature review on the subject. A case with particular interest is that of liquid bridges made of electrically conducting liquids forming between two conducting solids; such a liquid bridge presents an integral electrical conductance value which is sensitive to the specific silhouette of the bridge. This enables the use of this integral conductance as shape descriptor instead of the conventional image processing techniques. Several attempts in literature for the estimation of liquid surface tension, liquid-solid contact angle and surfactant induced surface elasticity for conducting or non/conducting liquids are presented and the prospects of the technique are discussed.

4.
Int J Pharm ; 478(2): 588-96, 2015 Jan 30.
Article in English | MEDLINE | ID: mdl-25433198

ABSTRACT

Foam sclerotherapy is a widely used method to treat varicose veins disease. It is easy to use and apply, affordable, and has high efficiency that depends on foam stability upon injection. Since sclerotherapy is usually applied in a medical doctor's office, one of the most employed methods to generate foam is based on the Tessari technique which uses pumping cycles of liquid and air in-and-out of a double syringe system. Finally, the produced foam exits through a small orifice (∼2mm) at the output of a three-way valve. The present work shows results regarding the factors that may influence foam stability (liquid to air ratio, type of connector, syringe diameter, number of pumping cycles, etc.) of a commonly used sclerosing agent (polidocanol). Furthermore, an effort is made to evaluate the effect of adding different substances on the stability of polidocanol foams (0.5% w/w) by altering the surface tension or/and the bulk and interfacial rheological properties of the fluids. It is shown that adding small concentrations of nonionic surfactants can increase foam stability with just a very small variation of the mean bubbles size.


Subject(s)
Polyethylene Glycols/chemistry , Sclerosing Solutions/chemistry , Surface-Active Agents/chemistry , Dosage Forms , Drug Stability , Glycerol/chemistry , Polidocanol , Polysaccharides, Bacterial/chemistry , Polysorbates/chemistry , Rheology , Sclerotherapy , Surface Properties , Syringes , Viscosity
5.
Water Res ; 37(12): 3023-33, 2003 Jul.
Article in English | MEDLINE | ID: mdl-12767306

ABSTRACT

The removal of a reactive color, Cibacron Yellow LS-R, from aqueous solutions by adsorption onto hydrotalcite particles is investigated using batch rate experiments. Measurements are performed at various initial color concentrations, solid loads, pH values and ionic backgrounds (dissolved NaCl). The speed of agitation and the temperature inside the batch adsorber are also varied within a practical range of values. It is shown that the sorption capacity is relatively high for most experimental conditions so hydrotalcite may be considered as a suitable sorbent for this application. The probable mechanism of the process is investigated by a number of homogeneous and heterogeneous reaction kinetic models as well as diffusion kinetic models. It is found that no single kinetic model can fully describe the sorption process at all times. At least three independent rate-controlling mechanisms appear to compete each other and dominate the different stages of sorption.


Subject(s)
Coloring Agents/chemistry , Water Purification/methods , Adsorption , Coloring Agents/isolation & purification , Diffusion , Hydrogen-Ion Concentration , Kinetics
6.
Colloids Surf B Biointerfaces ; 35(3-4): 159-67, 2004 Jun 01.
Article in English | MEDLINE | ID: mdl-15261027

ABSTRACT

A dynamic wicking technique is employed for the first time for the determination of the effective mean pore radius of a thin-layer porous food: drum dried pregelatinized starch sheets. The technique consists of measuring the penetration rate of various n-alkanes in the porous matrix of the starch sheets and using this data to calculate the effective pore radius via the Washburn equation. Pore sizes in the order of a few nanometers have been determined in the starch sheets depending on the drum dryer's operating variables (drum rotation speed, steam pressure and starch feed concentration). The conditions for the application of the technique in porous foods are discussed as compared to the conditions for single capillaries and inorganic porous material measured in other studies.


Subject(s)
Starch/analysis , Chemical Phenomena , Chemistry, Physical , Microscopy, Electron, Scanning , Particle Size , Porosity , Starch/ultrastructure , Surface Properties
7.
J Colloid Interface Sci ; 349(1): 408-16, 2010 Sep 01.
Article in English | MEDLINE | ID: mdl-20621814

ABSTRACT

Destabilization of hexane-in-water emulsions is studied by a continuous, non-intrusive, multi-probe, electrical conductance technique. Emulsions made of different oil fractions and surfactant (C(10)E(5)) concentrations are prepared in a stirred vessel using a Rushton turbine to break and agitate droplets. During the separation of phases, electrical signals from pairs of ring electrodes mounted at different heights onto the vessel wall, are recorded. The evolution of the local water volume fractions at the locations of the electrodes is estimated from these signals. It is found that in the absence of coalescence, the water fraction evolution curve from the bottom pair of electrodes is compatible with a bidisperse oil droplet size distribution. The sizes and volume fractions of the two droplet modes are estimated using theoretical arguments. The electrically determined droplet sizes are compared to data from microscopy image analysis. Results are discussed in detail.

SELECTION OF CITATIONS
SEARCH DETAIL