Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 63
Filter
1.
J Appl Clin Med Phys ; : e14322, 2024 Mar 04.
Article in English | MEDLINE | ID: mdl-38436611

ABSTRACT

PURPOSE: Predicting recurrence following stereotactic body radiotherapy (SBRT) for non-small cell lung cancer provides important information for the feasibility of the individualized radiotherapy and allows to select the appropriate treatment strategy based on the risk of recurrence. In this study, we evaluated the performance of both machine learning models using positron emission tomography (PET) and computed tomography (CT) radiomic features for predicting recurrence after SBRT. METHODS: Planning CT and PET images of 82 non-small cell lung cancer patients who performed SBRT at our hospital were used. First, tumors were delineated on each CT and PET of each patient, and 111 unique radiomic features were extracted, respectively. Next, the 10 features were selected using three different feature selection algorithms, respectively. Recurrence prediction models based on the selected features and four different machine learning algorithms were developed, respectively. Finally, we compared the predictive performance of each model for each recurrence pattern using the mean area under the curve (AUC) calculated following the 0.632+ bootstrap method. RESULTS: The highest performance for local recurrence, regional lymph node metastasis, and distant metastasis were observed in models using Support vector machine with PET features (mean AUC = 0.646), Naive Bayes with PET features (mean AUC = 0.611), and Support vector machine with CT features (mean AUC = 0.645), respectively. CONCLUSIONS: We comprehensively evaluated the performance of prediction model developed for recurrence following SBRT. The model in this study would provide information to predict the recurrence pattern and assist in making treatment strategies.

2.
J Appl Clin Med Phys ; : e14381, 2024 May 02.
Article in English | MEDLINE | ID: mdl-38696715

ABSTRACT

BACKGROUND: Surface-guided radiotherapy (SGRT) is adopted by several institutions; however, reports on the phantoms used to assess the precision of the SGRT setup are limited. PURPOSE: The purpose of this study was to develop a phantom to verify the accuracy of the irradiation position during skin mark-less SGRT. METHODS: An acrylonitrile butadiene styrene (ABS) plastic cube phantom with a diameter of 150 mm on each side containing a dummy target of 15 mm and two types of body surface-shaped phantoms (breast/face shape) that could be attached to the cube phantom were fabricated. Films can be inserted on four sides of the cubic phantom (left, right, anterior and posterior), and the center of radiation can be calculated by irradiating the dummy target with orthogonal MV beams. Three types of SGRT using a VOXELAN-HEV600M (Electronics Research&Development Corporation, Okayama, Japan) were evaluated using this phantom: (i) SGRTCT-a SGRT set-up based solely on a computed tomography (CT)-reference image. (ii) SGRTCT + CBCT-a method where cone beam computed tomography (CBCT) matching was performed after SGRTCT. (iii) SGRTScan-a resetup technique using a scan reference image obtained after completing the (ii) step. RESULTS: Both the breast and face phantoms were recognized in the SGRT system without problems. SGRTScan ensure precision within 1 mm/1° for breast and face verification, respectively. All SGRT methods showed comparable rotational accuracies with no significant disparities. CONCLUSIONS: The developed phantom was useful for verifying the accuracy of skin mark-less SGRT position matching. The SGRTScan demonstrated the feasibility of achieving skin-mark less SGRT with high accuracy, with deviations of less than 1 mm. Additional research is necessary to evaluate the suitability of the developed phantoms for use in various facilities and systems. This phantom could be used for postal surveys in the future.

3.
J Appl Clin Med Phys ; 24(12): e14142, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37672211

ABSTRACT

PURPOSE: This study aimed to compare fiducial markers used in CyberKnife treatment in terms of metal artifact intensity observed in CT images and fiducial recognition in the CyberKnife system affected by patient body thickness and type of marker. METHODS: Five markers, ACCULOC 0.9 mm × 3 mm, Ball type Gold Anchor (GA) 0.28 mm × 10 mm, 0.28 mm × 20 mm, and novel size GA 0.4 mm × 10 mm, 0.4 mm × 20 mm were evaluated. To evaluate metal artifacts of CT images, two types of CT images of water-equivalent gels with each marker were acquired using Aquilion LB CT scanner, one applied SEMAR (SEMAR-on) and the other did not apply this technique (SEMAR-off). The evaluation metric of artifact intensity (MSD ) which represents a variation of CT values were compared for each marker. Next, 5, 15, and 20 cm thickness of Tough Water (TW) was placed on the gel under the condition of overlapping the vertebral phantom in the Target Locating System, and the live image of each marker was acquired to compare fiducial recognition. RESULTS: The mean MSD of SEMAR-off was 78.80, 74.50, 97.25, 83.29, and 149.64 HU for ACCULOC, GA0.28 mm × 10 mm, 20 mm, and 0.40 mm × 10 mm, 20 mm, respectively. In the same manner, that of SEMAR-on was 23.52, 20.26, 26.76, 24.89, and 33.96 HU, respectively. Fiducial recognition decreased in the order of 5, 15, and 20 cm thickness, and GA 0.4 × 20 mm showed the best recognition at thickness of 20 cm TW. CONCLUSIONS: We demonstrated the potential to reduce metal artifacts in the CT image to the same level for all the markers we evaluated by applying SEMAR. Additionally, the fiducial recognition of each marker may vary depending on the thickness of the patient's body. Particularly, we showed that GA 0.40 × 20 mm may have more optimal recognition for CyberKnife treatment in cases of high bodily thickness in comparison to the other markers.


Subject(s)
Fiducial Markers , Radiotherapy, Image-Guided , Humans , Artifacts , Tomography, X-Ray Computed/methods , Radiotherapy, Image-Guided/methods , Gold , Water , Algorithms
4.
J Appl Clin Med Phys ; 23(4): e13529, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35018712

ABSTRACT

PURPOSE: This study aimed to evaluate the reproducibility of deep inspiration breath-hold (DIBH) using a respiratory control device, Abches, in patients with left-sided breast cancer. MATERIAL AND METHODS: Abches comprises a main body, an indicator panel, and two fulcrums, one each on the chest and abdomen. Forty left side breast cancer patients treated with DIBH using abches were enrolled in this study. For all patients, CT images were taken three times to confirm the target position inside the body and to check the breath-hold reproducibility. Three anatomical points on the nipple, sternum, and heart were selected as measurement points on CT images. After measuring the coordinates, breath-hold reproducibility was defined as the mean of the absolute difference in the coordinates between the three CT images. The maximum differences were also investigated. In addition, the dice similarity coefficient (DSC) was calculated to examine the displacement of the heart volume in detail. Moreover, digitally reconstructed radiographs (DRRs) and linac graphs (LGs) were used to measure the positional accuracy of the chest and heart. RESULTS: The reproducibility in all patients was within 0.75 mm for the nipple, 0.78 mm for the sternum, and 2.18 mm for the heart in each direction. Similarly, the maximum displacements for all patients were within 1.90 mm, 1.69 mm, and 4.75 mm, respectively, in each direction. For heart volume, the average DSC for all cases was 0.93 ± 0.01. The differences between the DRR and LG images were 1.70 ± 1.10 mm and 2.10 ± 1.60 mm, for the chest and heart, respectively. CONCLUSION: Our study showed that DIBH using Abches can be performed with good target reproducibility of less than 3 mm with proper breath-hold practice, whereas the heartbeat-derived reproducibility of the cardiac position is poor and needs to be monitored carefully during treatment simulation.


Subject(s)
Breast Neoplasms , Thoracic Wall , Unilateral Breast Neoplasms , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/radiotherapy , Breath Holding , Female , Heart , Humans , Organs at Risk , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Reproducibility of Results , Unilateral Breast Neoplasms/diagnostic imaging , Unilateral Breast Neoplasms/radiotherapy
5.
Rep Pract Oncol Radiother ; 27(4): 699-706, 2022.
Article in English | MEDLINE | ID: mdl-36196413

ABSTRACT

Background: This study aimed to investigate whether ipsilateral lung doses (ILDs) could be predicted by anatomical indexes measured using diagnostic computed tomography (CT) prior to the planning stage of breast radiation therapy (RT). Materials and methods: The thoracic diameters and the length of lines drawn manually were measured on diagnostic CT images. The parameters of interest were the skin maximum lung distance (sMLD), central lung distance (CLD), Haller index (HI), and body mass index (BMI). Lung dose-volume histograms were created with conformal planning, and the lung volumes receiving 5-40 Gy (V5-V40) were calculated. Linear regression models were used to investigate the correlations between the anatomical indexes and dose differences and to estimate the slope and 95% confidence intervals (CIs). Results: A total of 160 patients who had undergone three-dimensional conformal RT after breast-conserving surgery were included. Univariable analysis revealed that the sMLD (p < 0.001), CLD (p < 0.001), HI (p = 0.002), and BMI (p < 0.001) were significantly correlated with the V20. However, multivariable analysis revealed that only the sMLD (slope: 0.147, p = 0.001, 95% CI: 0.162-0.306) and CLD (0.157, p = 0.005, 0.048-0.266) were strongly correlated with the V20. The p-value for the sMLD was the lowest among the p-values for all indexes, thereby indicating that the sMLD had the best predictive power for ILD. Conclusions: sMLD and CLD are anatomical markers that can be used to predict ILD in whole breast RT. An sMLD > 20.5 mm or a CLD > 24.3 mm positively correlated with a high ILD.

6.
Rep Pract Oncol Radiother ; 26(3): 495-501, 2021.
Article in English | MEDLINE | ID: mdl-34277107

ABSTRACT

BACKGROUND: 3-dimensional intra-cone beam computed tomography (intra-CBCT ) could be a potentially powerful tool for use with arc irradiation such as volumetric modulated arc therapy. The aim of the study was to evaluate the image quality of intra-cone beam computed tomography (intra-CBCT ) for arc irradiation with various imaging condition. MATERIALS AND METHODS: Two types of intra-CBCT imaging techniques were evaluated - intra-fractional CBCT with flattening filtered (FF) beam (intra-FF CBCT ) and that with flattening filter free (FFF) beam (intra-FFF CBCT ). For the intra-MV beams, four different field sizes (2 cm × 2 cm, 5 cm × 5 cm, 10 cm × 10 cm, and 20 cm × 20 cm) were used with dose rates of 500 MU/min and 1600 MU/min, for 6 MV FF and 6 MV FFF, respectively. For all image acquisitions, two rotation angles (full-arc and half-arc) were investigated. Thereafter, the linearity, contrast-to-noise ratio (CNR), and uniformity index (UI) of intra-CBCT image were compared with those of conventional CBCT image. RESULTS: All acquisition conditions had good linearity of the CT value (R2 > 0.99). For CNR, the change rates from conventional CBCT ranged from 0.6-33.7% for a 2 cm × 2 cm beam, whereas that for a 20 cm × 20 cm beam ranged from 62.7-82.3%. Similarly, the UI increased from 1.5% to 7.0% as the field size increased. CONCLUSION: Quality of intra-CBCT image was affected by the field size and acquisition angle. Image quality of intra-CBCT was worse than that of conventional CBCT, but it was better under a smaller field and wider correction angle and would be acceptable for clinical use.

7.
J Appl Clin Med Phys ; 2020 Aug 10.
Article in English | MEDLINE | ID: mdl-33058517

ABSTRACT

The purpose of this study was to evaluate the effect of a hydrogel spacer on intrafractional prostate motion during CyberKnife treatment. The retrospective study enrolled 24 patients (with the hydrogel spacer = 12, without the hydrogel spacer = 12) with two fiducial markers. Regarding intrafractional prostate motion, the offset values (mm) of three axes (X-axis; superior [+] to inferior [-], Y-axis; right [+] to left [-], Z-axis; posterior [+] to anterior [-]) obtained from fiducial markers position between a digitally reconstructed radiographs images and live images in the Target Locating System were used, and extracted from generated log files. The mean values of the offset and each standard deviation were calculated for each patient, and both the groups were compared. For all the patients, a total of 2204 offset values and timestamps (without the hydrogel spacer group: 1065, with the hydrogel spacer group: 1139) were recorded for the X-, Y-, and Z-axes, respectively. The offset values (mean ± standard deviation) for the X-, Y-, and Z-axes were -0.04 ± 0.92 mm, -0.03 ± 0.97 mm (P = 0.66), 0.02 ± 0.51, -0.02 ± 0.49 mm (P = 0.50), and 0.56 ± 0.97 mm, 0.34 ± 1.07 mm (P = 0.14), in patients inserted without or with the hydrogel spacer, respectively. There was no effect of a hydrogel spacer on the intrafractional prostate motion in the three axes during CyberKnife treatment for prostate cancer.

8.
Rep Pract Oncol Radiother ; 25(2): 200-205, 2020.
Article in English | MEDLINE | ID: mdl-32021577

ABSTRACT

AIM: To evaluate the target dose coverage for lung stereotactic body radiotherapy (SBRT) using helical tomotherapy (HT) with the internal tumor volume (ITV) margin settings adjusted according to the degree of tumor motion. BACKGROUND: Lung SBRT with HT may cause a dosimetric error when the target motion is large. MATERIALS AND METHODS: Two lung SBRT plans were created using a tomotherapy planning station. Using these original plans, five plans with different ITV margins (4.0-20.0 mm for superior-inferior [SI] dimension) were generated. To evaluate the effects of respiratory motion on HT, an original dynamic motion phantom was developed. The respiratory wave of a healthy volunteer was used for dynamic motion as the typical tumor respiratory motion. Five patterns of motion amplitude that corresponded to five ITV margin sizes and three breathing cycles of 7, 14, and 28 breaths per minute were used. We evaluated the target dose change between a static delivery and a dynamic delivery with each motion pattern. RESULTS: The target dose difference increased as the tumor size decreased and as the tumor motion increased. Although a target dose difference of <5 % was observed at ≤10 mm of tumor motion for each condition, a maximum difference of -9.94 % ± 7.10 % was observed in cases of small tumors with 20 mm of tumor motion under slow respiration. CONCLUSIONS: Minimizing respiratory movement is recommended as much as possible for lung SBRT with HT, especially for cases involving small tumors.

9.
Rep Pract Oncol Radiother ; 25(1): 117-124, 2020.
Article in English | MEDLINE | ID: mdl-31908605

ABSTRACT

AIM: The aim of the study was to evaluate computed tomography (CT) artifacts and image recognition of the CyberKnife system. Regarding fiducial markers, VISICOIL of 0.5 mm × 5.0 mm and 0.75 mm × 5.0 mm, ball-shaped Gold Anchor (GA) of 0.28 mm × 10 mm and 0.28 mm × 20 mm, were compared with the standard cylinder marker of 0.9 mm × 3.0 mm (ACCULOC). BACKGROUND: Recently, various kinds of commercial fiducial markers have been available in CyberKnife treatment. MATERIALS AND METHODS: The CT images of a water equivalent gel with each fiducial marker were acquired for the evaluation of CT artifacts. The evaluation was performed using the standard deviation of Hounsfield Unit (HU) value for a rectangle region near the fiducial marker. Then, to evaluate the image recognition, each fiducial marker was located to overlap in the target locating system (TLS) for the two sites; the vertebral bone and the pubic bone. RESULTS: For CT artifacts, the standard deviations of the VISICOIL of 0.5 mm × 5.0 mm was the smallest. The image recognition of four fiducial markers had a value close to the standard cylinder marker and was feasible for common use, but was slightly poorer when using GA of 0.28 mm × 10 mm in the dynamic conditions. CONCLUSION: Our results indicated that VISICOIL 0.5 × 5.0 mm and the GAs can be used nearly always for CyberKnife treatment in spite of their much thinner needles than those of cylinder types.

10.
Int J Clin Oncol ; 23(6): 1015-1022, 2018 Dec.
Article in English | MEDLINE | ID: mdl-29971621

ABSTRACT

BACKGROUND: To determine the current practice of stereotactic irradiation (STI) for brain metastases in Japan by a questionnaire survey. METHODS: A questionnaire was distributed to 313 institutions performing STI with one of the following machines: Gamma Knife (GK), CyberKnife (CK), Novalis (Nov), or other linear accelerator (LINAC)-based systems (OLS). The participation was voluntary. RESULTS: There were 163 responding institutions. The total number of STI treatments between April 2013 and March 2014 was 10,684. Stereotactic radiosurgery (SRS) and fractionated stereotactic radiotherapy (SRT) were performed in 8624 (80.7%) and 2060 (19.3%) cases, respectively. Whole-brain radiation therapy (WBRT) was performed for a total of 3515 cases. For a case model of a 1.5-cm solitary brain metastasis in a non-eloquent area, the most common GTV-PTV margin was 2 mm (22 of 114 institutions), and an institutional standard fraction was 1 (75 of 114 institutions). The doses for the model case also varied from 13.0 to 26.0 Gy (Median 20 Gy) when converted to SRS (α/ß = 10). A prescription point was at the PTV margin the most. The median dose constraints which were converted to SRS (α/ß = 3) to organs at risk were 12.2, 12.7, and 13.7 Gy for optic nerves, cavernous sinus, and brainstem, respectively. CONCLUSIONS: STI for brain metastases in current practice varied significantly among institutions. These different strategies relied mostly on the type of treatment machine used. It is thus necessary to establish a common guideline to express dose prescriptions and plan qualities for different STI machines.


Subject(s)
Brain Neoplasms/surgery , Practice Patterns, Physicians'/trends , Radiation Oncology/standards , Radiosurgery/methods , Brain Neoplasms/secondary , Humans , Japan , Surveys and Questionnaires
11.
J Appl Clin Med Phys ; 19(3): 87-93, 2018 May.
Article in English | MEDLINE | ID: mdl-29500857

ABSTRACT

The purpose of this study was to compare the MLC error sensitivity of various measurement devices for VMAT pre-treatment quality assurance (QA). This study used four QA devices (Scandidos Delta4, PTW 2D-array, iRT systems IQM, and PTW Farmer chamber). Nine retrospective VMAT plans were used and nine MLC error plans were generated for all nine original VMAT plans. The IQM and Farmer chamber were evaluated using the cumulative signal difference between the baseline and error-induced measurements. In addition, to investigate the sensitivity of the Delta4 device and the 2D-array, global gamma analysis (1%/1, 2%/2, and 3%/3 mm), dose difference (1%, 2%, and 3%) were used between the baseline and error-induced measurements. Some deviations of the MLC error sensitivity for the evaluation metrics and MLC error ranges were observed. For the two ionization devices, the sensitivity of the IQM was significantly better than that of the Farmer chamber (P < 0.01) while both devices had good linearly correlation between the cumulative signal difference and the magnitude of MLC errors. The pass rates decreased as the magnitude of the MLC error increased for both Delta4 and 2D-array. However, the small MLC error for small aperture sizes, such as for lung SBRT, could not be detected using the loosest gamma criteria (3%/3 mm). Our results indicate that DD could be more useful than gamma analysis for daily MLC QA, and that a large-area ionization chamber has a greater advantage for detecting systematic MLC error because of the large sensitive volume, while the other devices could not detect this error for some cases with a small range of MLC error.


Subject(s)
Neoplasms/radiotherapy , Phantoms, Imaging , Quality Assurance, Health Care/standards , Radiometry/instrumentation , Radiotherapy Planning, Computer-Assisted/instrumentation , Radiotherapy Setup Errors/prevention & control , Radiotherapy, Intensity-Modulated/standards , Gamma Rays , Humans , Image Processing, Computer-Assisted/methods , Organs at Risk/radiation effects , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/instrumentation , Radiotherapy, Intensity-Modulated/methods , Retrospective Studies , Tomography, X-Ray Computed/methods
12.
BMC Cancer ; 13: 68, 2013 Feb 07.
Article in English | MEDLINE | ID: mdl-23391264

ABSTRACT

BACKGROUND: As stereotactic body radiotherapy (SBRT) is a highly dose-dense radiotherapy, adverse events of neighboring normal tissues are a major concern. This study thus aimed to clarify the frequency and degree of clinical symptoms in patients with rib fractures after SBRT for primary lung cancer and to reveal risk factors for rib fracture. Appropriate α/ß ratios for discriminating between fracture and non-fracture groups were also investigated. METHODS: Between November 2001 and April 2009, 177 patients who had undergone SBRT were evaluated for clinical symptoms and underwent follow-up thin-section computed tomography (CT). The time of rib fracture appearance was also assessed. Cox proportional hazard modeling was performed to identify risk factors for rib fracture, using independent variables of age, sex, maximum tumor diameter, radiotherapeutic method and tumor-chest wall distance. Dosimetric details were analyzed for 26 patients with and 22 randomly-sampled patients without rib fracture. Biologically effective dose (BED) was calculated with a range of α/ß ratios (1-10 Gy). Receiver operating characteristics analysis was used to define the most appropriate α/ß ratio. RESULTS: Rib fracture was found on follow-up thin-section CT in 41 patients. The frequency of chest wall pain in patients with rib fracture was 34.1% (14/41), and was classified as Grade 1 or 2. Significant risk factors for rib fracture were smaller tumor-chest wall distance and female sex. Area under the curve was maximal for BED at an α/ß ratio of 8 Gy. CONCLUSIONS: Rib fracture is frequently seen on CT after SBRT for lung cancer. Small tumor-chest wall distance and female sex are risk factors for rib fracture. However, clinical symptoms are infrequent and generally mild. When using BED analysis, an α/ß ratio of 8 Gy appears most effective for discriminating between fracture and non-fracture patients.


Subject(s)
Adenocarcinoma/surgery , Lung Neoplasms/surgery , Radiation Injuries/epidemiology , Radiosurgery/adverse effects , Rib Fractures/epidemiology , Adenocarcinoma of Lung , Aged , Aged, 80 and over , Area Under Curve , Chest Pain/epidemiology , Edema/epidemiology , Female , Humans , Japan/epidemiology , Kaplan-Meier Estimate , Male , Middle Aged , Pain Measurement , Pilot Projects , Predictive Value of Tests , Prevalence , Proportional Hazards Models , ROC Curve , Radiation Dosage , Radiation Injuries/diagnostic imaging , Rib Fractures/diagnostic imaging , Risk Factors , Sex Factors , Time Factors , Tomography, X-Ray Computed
13.
Radiol Phys Technol ; 16(2): 292-298, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37079253

ABSTRACT

To report the long-term quality assurance (QA) experience of an on-rail computed tomography (CT) system for image-guided radiotherapy using an in-house phantom. An on-rail CT system combining the Elekta Synergy and Canon Aquilion LB was used. The treatment couch was shared by the linear accelerators and CT, and the couch was rotated by 180° when using the on-rail-CT system to ensure that the CT direction was toward the head. All QA analyses were performed by radiation technologists on CBCT or on-rail CT images of the in-house phantom. The CBCT center accuracy from the linac laser, couch rotational accuracy (CBCT center vs. on-rail CT center), horizontal accuracy by CT gantry shift, and remote couch shift accuracy were evaluated. This study reported the QA status of the system during the period 2014-2021. The absolute mean accuracy of couch rotation was 0.4 ± 0.28 mm, 0.44 ± 0.36 mm, and 0.37 ± 0.27 mm in the SI, RL, and AP directions, respectively. Horizontal and remote movement accuracies of the treatment couch were also within 0.5 mm of the absolute mean value. A decrease in the accuracy of couch rotation was also observed due to aging deterioration of related parts caused by the frequent use of couch rotation. The three-dimensional accuracy of on-rail CT systems derived mainly from treatment couches can be maintained within 0.5 mm with appropriate accuracy assurance for at least > 8 years.


Subject(s)
Radiosurgery , Radiotherapy, Image-Guided , Radiotherapy, Image-Guided/methods , Tomography, X-Ray Computed/methods , Tomography Scanners, X-Ray Computed , Particle Accelerators , Phantoms, Imaging , Radiotherapy Planning, Computer-Assisted
14.
Thorac Cancer ; 14(35): 3445-3452, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37846145

ABSTRACT

BACKGROUND: The purpose of this study was to compare the dosimetric characteristics of five different treatment planning techniques for locally advanced non-small cell lung cancer (LA-NSCLC) with sequential plan changes. METHODS: A total of 13 stage III NSCLC patients were enrolled in this study. These patients had both computed tomography (CT) images for initial and boost treatment plans. The latter CT images were taken if tumor shrinkage was observed after 2 weeks of treatment. The prescription dose was 60 Gy/30 Fr (initial: 40 Gy/20 Fr, and boost: 20 Gy/10 Fr). Five techniques (forward-planed 3-dimensional conformal radiotherapy [F-3DCRT] on both CT images, inverse-planned 3DCRT [I-3DCRT] on both CT images, volumetric modulated arc therapy [VMAT] on both CT images, F-3DCRT on initial CT plus VMAT on boost CT [bVMAT], and hybrid of fixed intensity-modulated radiotherapy [IMRT] beams and VMAT beams on both CT images [hybrid]) were recalculated for all patients. The accumulated doses between initial and boost plans were compared among all treatment techniques. RESULTS: The conformity indexes (CI) of the planning target volume (PTV) of the five planning techniques were 0.34 ± 0.10, 0.57 ± 0.10, 0.86 ± 0.08, 0.61 ± 0.12, and 0.83 ± 0.11 for F-3DCRT, I-3DCRT, VMAT, bVMAT, and hybrid, respectively. In the same manner, lung volumes receiving >20 Gy (V20Gy ) were 21.05 ± 10.56%, 20.86 ± 6.45, 19.50 ± 7.38%, 19.98 ± 10.04%, and 17.74 ± 7.86%. There was significant improvement about CI and V20Gy for hybrid compared with F-3DCRT (p < 0.05). CONCLUSION: The IMRT/VMAT hybrid technique for LA-NSCLC patients improved target CI and reduced lung doses. Furthermore, if IMRT was not available initially, starting with 3DCRT might be beneficial as demonstrated in the bVMAT procedure of this study.


Subject(s)
Carcinoma, Non-Small-Cell Lung , Lung Neoplasms , Radiotherapy, Conformal , Humans , Carcinoma, Non-Small-Cell Lung/radiotherapy , Carcinoma, Non-Small-Cell Lung/etiology , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy Dosage , Lung Neoplasms/radiotherapy , Lung Neoplasms/etiology , Radiotherapy, Conformal/methods
15.
Cancers (Basel) ; 15(17)2023 Sep 01.
Article in English | MEDLINE | ID: mdl-37686657

ABSTRACT

Surgery is the standard treatment for stage I non-small cell lung cancer (NSCLC); however, no clear randomized trial demonstrates its superiority to stereotactic body radiotherapy (SBRT) regarding survival. We aimed to retrospectively evaluate the treatment outcomes of SBRT in operable patients with stage I NSCLC using a large Japanese multi-institutional database to show real-world outcome. Exactly 399 patients (median age 75 years; 262 males and 137 females) with stage I (IA 292, IB 107) histologically proven NSCLC (adenocarcinoma 267, squamous cell carcinoma 96, others 36) treated at 20 institutions were reviewed. SBRT was prescribed at a total dose of 48-70 Gy in 4-10 fractions. The median follow-up period was 38 months. Local progression-free survival rates were 84.2% in all patients and 86.1% in the T1, 78.6% in T2, 89.2% in adenocarcinoma, and 70.5% in squamous cell subgroups. Overall 3-year survival rates were 77.0% in all patients: 90.7% in females, 69.6% in males, and 41.2% in patients with pulmonary interstitial changes. Fatal radiation pneumonitis was observed in two patients, all of whom had pulmonary interstitial changes. This real-world evidence will be useful in shared decision-making for optimal treatment, including SBRT for operable stage I NSCLC, particularly in older patients.

16.
Adv Radiat Oncol ; 8(4): 101205, 2023.
Article in English | MEDLINE | ID: mdl-37077179

ABSTRACT

Purpose: The aim of this study was to understand the income and employment status of patients at the start of and during follow-up after palliative radiation therapy for bone metastasis. Methods and Materials: From December 2020 to March 2021, a prospective multi-institutional observational study was conducted to investigate income and employment of patients at the start of administration of radiation therapy for bone metastasis and at 2 and 6 months after treatment. Of 333 patients referred to radiation therapy for bone metastasis, 101 were not registered, mainly because of their poor general condition, and another 8 were excluded from the follow-up analysis owing to ineligibility. Results: In 224 patients analyzed, 108 had retired for reasons unrelated to cancer, 43 had retired for reasons related to cancer, 31 were taking leave, and 2 had lost their jobs at the time of registration. The number of patients who were in the working group was 40 (30 with no change in income and 10 with decreased income) at registration, 35 at 2 months, and 24 at 6 months. Younger patients (P = 0), patients with better performance status (P = 0), patients who were ambulatory (P = .008), and patients with lower scores on a numerical rating scale of pain (P = 0) were significantly more likely to be in the working group at registration. There were 9 patients who experienced improvements in their working status or income at least once in the follow-up after radiation therapy. Conclusions: The majority of patients with bone metastasis were not working at the start of or after radiation therapy, but the number of patients who were working was not negligible. Radiation oncologists should be aware of the working status of patients and provide appropriate support for each patient. The benefit of radiation therapy to support patients continuing their work and returning to work should be investigated further in prospective studies.

17.
Br J Radiol ; 96(1151): 20230351, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37750858

ABSTRACT

OBJECTIVE: To identify factors significantly associated with quality of life (QOL) and determine if these associations are strong enough to predict certain aspects of QOL without measuring them. METHODS: We conducted an exploratory secondary analysis of baseline data of 224 patients (enrolled between December 2020 and March 2021) from a previously published prospective observational study on radiotherapy for bone metastases at 26 centres. Using univariable linear regression, we assessed the association between patient/treatment factors and QOL scale scores as measured by the European Organization for Research and Treatment of Cancer (EORTC) QOL Questionnaire Core 15-Palliative (QLQ-C15-PAL) and the EORTC QOL Questionnaire Bone Metastases module (QLQ-BM22). RESULTS: Age and sex were not significantly associated with QOL. Worse performance status, higher pain scores, and opioid and single-fraction use were significantly associated with most QOL scales; these four factors were associated with worse global QOL, worse functioning status, and more severe symptoms. The coefficients of determination for most QOL scales were less than 0.2, indicating that most of the variability in QOL scores was not explained by any of the explanatory variables. CONCLUSION: Performance status, pain intensity, and opioid and single-fraction use were significantly associated with most QOL scales. However, the associations were not strong enough to estimate QOL. ADVANCES IN KNOWLEDGE: To date, the association between treatment factors and QOL in patients with bone metastases has not been fully studied. We identified the factors that were significantly associated with QOL and found that these associations were not strong enough to predict QOL.


Subject(s)
Bone Neoplasms , Quality of Life , Humans , Cross-Sectional Studies , Prospective Studies , Analgesics, Opioid , Bone Neoplasms/pathology , Palliative Care , Surveys and Questionnaires
18.
J Radiat Res ; 63(3): 435-442, 2022 May 18.
Article in English | MEDLINE | ID: mdl-35467750

ABSTRACT

The purpose of this study is to evaluate the detection accuracy of a 3-dimensional (3D) body scanner, VOXELAN, in surface-guided radiotherapy (SGRT) of each part of the human body using a whole-body human phantom. We used A Resusci Anne was used as the whole-body phantom. The detection accuracy of VOXELAN in a radiotherapy treatment room with a linear accelerator (LINAC) was evaluated for two reference images: reconstruction of the planning computed tomography (CT) image (CT reference) and scanning by VOXELAN before the treatment (scan reference). The accuracy of the translational and rotational directions was verified for four treatment sites (open face shell, breast, abdomen, and arm), using the magnitude of the 6D robotic couch movement as the true value. Our results showed that the detection accuracy improved as the displacement from the reference position decreased for all the sites. Using the scan reference, the average accuracy of the translational and rotational axes was within 1.44 mm and 0.41°, respectively, for all sites except the arms. Similarly, using the CT reference, the average accuracy was within 2.45 mm and 1.35°, respectively. Additionally, it was difficult for both reference images to recognize misalignment of the arms. In conclusion we discovered that VOXELAN achieved a high detection accuracy for the head with an open face shell, chest, and abdomen, indicating that the system is useful in a clinical setting. However, it is necessary to pay attention to location matching for areas with few features, such as surface irregularities and potential errors, when the reference image is created from CT.


Subject(s)
Brachytherapy , Radiotherapy, Image-Guided , Humans , Particle Accelerators , Phantoms, Imaging , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Image-Guided/methods , Tomography, X-Ray Computed
19.
Cancers (Basel) ; 14(9)2022 May 07.
Article in English | MEDLINE | ID: mdl-35565447

ABSTRACT

A crucial issue in radical radiation therapy for non-small-cell lung cancer is how to define the clinical target volume (CTV). Although the scope of microscopic extension (ME) and microscopic proximal bronchial extension (PBE) from a primary tumor should be considered when defining the CTV, there has been limited research on ME and PBE. Therefore, we conducted this systematic review. The PubMed, ICHUSHI (Japanese database), and Cochrane Library databases were searched, and 816 articles were initially retrieved. After primary and secondary screenings, eight articles were ultimately selected. The results of this systematic review suggest the importance of a 0 mm margin in stereotactic radiotherapy for early-stage cancer and a 5-8 mm margin in curative irradiation for locally advanced cancer. Regarding PBE, this review yielded the conclusion that it is appropriate to consider the addition of an approximately 15 mm margin from the bronchial vasculature. Although there were few articles with a high level of evidence, this systematic review enabled us to collate results from previous studies and to provide recommendations, to some extent, regarding the CTV margin in the current clinical environment, where high-precision radiation therapy, such as image-guided radiotherapy and intensity-modulated radiotherapy, is predominant.

20.
Pract Radiat Oncol ; 12(6): e556-e559, 2022.
Article in English | MEDLINE | ID: mdl-35144015

ABSTRACT

PURPOSE: The present study evaluated the short-term characteristics (<3 days) of a hydrogel spacer from the time of injection during stereotactic body radiation therapy (SBRT) for prostate cancer. METHODS AND MATERIALS: Fifteen patients treated with SBRT via the CyberKnife system (36.25 Gy/5 fractions) were enrolled in this retrospective study. Two magnetic resonance (MR) images were obtained with a hydrogel spacer: one on a computed tomography (CT) simulation day (MR pretreatment [MRpre]) and the other on the last treatment day (MR posttreatment [MRpost]). Two medical physicists contoured the hydrogel spacer on each MR image. The changes of the shapes and the volume for the hydrogel spacer between 2 MR images were evaluated. RESULTS: The median period between hydrogel spacer injection and CT simulation was 1 day (range, 1-9 days). The median period between CT simulation and the last treatment was 17 days (range, 14-25 days). Regarding the volume change of the hydrogel spacer, the 2 observers observed significant differences between the volumes of the hydrogel spacer on the MRpre and MRpost. However, the average volume difference between them was less than 1 cm3. The average dice similarity coefficient between the MRpre and MRpost to compare the shape was more than 0.83. In addition, no clear correlation was confirmed between the volume change and the period from hydrogel spacer injection to CT simulation. CONCLUSIONS: A single day is an acceptable interval between hydrogel spacer injection and treatment planning for SBRT for prostate cancer.


Subject(s)
Prostatic Neoplasms , Radiosurgery , Male , Humans , Radiosurgery/methods , Hydrogels , Retrospective Studies , Rectum , Prostatic Neoplasms/radiotherapy , Prostatic Neoplasms/surgery , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods
SELECTION OF CITATIONS
SEARCH DETAIL