Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters

Database
Language
Publication year range
1.
Appl Opt ; 61(14): 4215-4225, 2022 May 10.
Article in English | MEDLINE | ID: mdl-36256099

ABSTRACT

During 2019, an infrared camera, the compact thermal imager (CTI), recorded 15 million images of the Earth from the International Space Station. CTI is based on strained-layer superlattice (SLS) detector technology. The camera covered the spectral range from 3 to 11 µm in two spectral channels, 3.3-5.4 and 7.8-10.7 µm. Individual image frames were 26×21km2 projected on the ground, with 82 m pixel resolution. A frame time of 2.54 s created continuous image swaths with a 13% along-track image overlap. Upper limits determined on the ground and in flight for the electronic offset, read noise, and dark current demonstrated the stability of the SLS detector and camera over many months. Temperature calibration was established using a combination of preflight and in-flight measurements. A narrowband approximation of temperature as a function of photon counts produced an analytic relationship covering a temperature range of 0°-400°C. Examples of CTI images illustrate temperature retrievals over sea ice, urban and agricultural areas, desert, and wildfires.

2.
Fertil Steril ; 58(5): 1000-5, 1992 Nov.
Article in English | MEDLINE | ID: mdl-1426349

ABSTRACT

OBJECTIVES: To assess the ability of sperm aspirated from the epididymis of men with congenital absence of the vas deferens to penetrate zona-free hamster oocytes. To directly compare the performance of human epididymal sperm in the zona-free hamster oocyte sperm penetration assay (SPA) with the results of human in vitro fertilization (IVF). DESIGN: Sperm penetration assay was carried out with epididymal sperm retrieved microsurgically, and with ejaculated sperm obtained from fertile donors (internal controls). For direct comparison, SPA was performed with the same epididymal sperm sample used for IVF. PATIENTS, PARTICIPANTS: Men with congenital absence of the vas deferens undergoing sperm aspiration as part of their infertility treatment and control donors who provided ejaculated sperm. RESULTS: Epididymal sperm penetrated SPA with a score of 0% to 30%. The SPA scores for internal controls using ejaculated sperm was 30% to 71%. Linear regression analysis of the association between penetration scores in SPA and fertilization rate in IVF indicated a positive correlation that was highly significative. CONCLUSIONS: These findings using SPA confirm previous reports on the fertilizing potential of human epididymal sperm and its ability to produce normal pregnancies. The good correlation between SPA and human IVF using epididymal sperm suggest that SPA is an excellent bioassay to test laboratory experimental conditions for improving fertilizing capacity of human epididymal sperm.


Subject(s)
Epididymis/cytology , Infertility, Male/etiology , Infertility, Male/therapy , Oocytes/physiology , Sperm-Ovum Interactions , Spermatozoa/physiology , Vas Deferens/abnormalities , Adult , Animals , Cricetinae , Female , Fertilization in Vitro , Humans , Male , Regression Analysis , Zona Pellucida/physiology
SELECTION OF CITATIONS
SEARCH DETAIL