Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 352
Filter
1.
Circulation ; 148(24): 1932-1944, 2023 12 12.
Article in English | MEDLINE | ID: mdl-37855144

ABSTRACT

BACKGROUND: The consequences of exercise-induced premature ventricular contractions (PVCs) in asymptomatic individuals remain unclear. This study aimed to assess the association between PVC burdens during submaximal exercise and major adverse cardiovascular events (MI/HF/LTVA: myocardial infarction [MI], heart failure [HF], and life-threatening ventricular arrhythmia [LTVA]), and all-cause mortality. Additional end points were MI, LTVA, HF, and cardiovascular mortality. METHODS: A neural network was developed to count PVCs from ECGs recorded during exercise (6 minutes) and recovery (1 minute) in 48 315 asymptomatic participants from UK Biobank. Associations were estimated using multivariable Cox proportional hazard models. Explorative studies were conducted in subgroups with cardiovascular magnetic resonance imaging data (n=6290) and NT-proBNP (N-terminal Pro-B-type natriuretic peptide) levels (n=4607) to examine whether PVC burden was associated with subclinical cardiomyopathy. RESULTS: Mean age was 56.8±8.2 years; 51.1% of the participants were female; and median follow-up was 12.6 years. Low PVC counts during exercise and recovery were both associated with MI/HF/LTVA risk, independently of clinical factors: adjusted hazard ratio (HR), 1.2 (1-5 exercise PVCs, P<0.001) and HR, 1.3 (1-5 recovery PVCs, P<0.001). Risks were higher with increasing PVC count: HR, 1.8 (>20 exercise PVCs, P<0.001) and HR, 1.6 (>5 recovery PVCs, P<0.001). A similar trend was observed for all-cause mortality, although associations were only significant for high PVC burdens: HRs, 1.6 (>20 exercise PVCs, P<0.001) and 1.5 (>5 recovery PVCs, P<0.001). Complex PVC rhythms were associated with higher risk compared with PVC count alone. PVCs were also associated with incident HF, LTVA, and cardiovascular mortality, but not MI. In the explorative studies, high PVC burden was associated with larger left ventricular volumes, lower ejection fraction, and higher levels of NT-proBNP compared with participants without PVCs. CONCLUSIONS: In this cohort of middle-aged and older adults, PVC count during submaximal exercise and recovery were both associated with MI/HF/LTVA, all-cause mortality, HF, LTVAs, and cardiovascular mortality, independent of clinical and exercise test factors, indicating an incremental increase in risk as PVC count rises. Complex PVC rhythms were associated with higher risk compared with PVC count alone. Underlying mechanisms may include the presence of subclinical cardiomyopathy.


Subject(s)
Cardiomyopathies , Heart Failure , Myocardial Infarction , Ventricular Premature Complexes , Middle Aged , Humans , Female , Aged , Male , Prognosis , Ventricular Premature Complexes/complications , Biological Specimen Banks , Heart Failure/complications , Cardiomyopathies/complications , Myocardial Infarction/complications
2.
Circulation ; 148(10): 808-818, 2023 09 05.
Article in English | MEDLINE | ID: mdl-37463608

ABSTRACT

BACKGROUND: In hypertrophic cardiomyopathy (HCM), myocyte disarray and microvascular disease (MVD) have been implicated in adverse events, and recent evidence suggests that these may occur early. As novel therapy provides promise for disease modification, detection of phenotype development is an emerging priority. To evaluate their utility as early and disease-specific biomarkers, we measured myocardial microstructure and MVD in 3 HCM groups-overt, either genotype-positive (G+LVH+) or genotype-negative (G-LVH+), and subclinical (G+LVH-) HCM-exploring relationships with electrical changes and genetic substrate. METHODS: This was a multicenter collaboration to study 206 subjects: 101 patients with overt HCM (51 G+LVH+ and 50 G-LVH+), 77 patients with G+LVH-, and 28 matched healthy volunteers. All underwent 12-lead ECG, quantitative perfusion cardiac magnetic resonance imaging (measuring myocardial blood flow, myocardial perfusion reserve, and perfusion defects), and cardiac diffusion tensor imaging measuring fractional anisotropy (lower values expected with more disarray), mean diffusivity (reflecting myocyte packing/interstitial expansion), and second eigenvector angle (measuring sheetlet orientation). RESULTS: Compared with healthy volunteers, patients with overt HCM had evidence of altered microstructure (lower fractional anisotropy, higher mean diffusivity, and higher second eigenvector angle; all P<0.001) and MVD (lower stress myocardial blood flow and myocardial perfusion reserve; both P<0.001). Patients with G-LVH+ were similar to those with G+LVH+ but had elevated second eigenvector angle (P<0.001 after adjustment for left ventricular hypertrophy and fibrosis). In overt disease, perfusion defects were found in all G+ but not all G- patients (100% [51/51] versus 82% [41/50]; P=0.001). Patients with G+LVH- compared with healthy volunteers similarly had altered microstructure, although to a lesser extent (all diffusion tensor imaging parameters; P<0.001), and MVD (reduced stress myocardial blood flow [P=0.015] with perfusion defects in 28% versus 0 healthy volunteers [P=0.002]). Disarray and MVD were independently associated with pathological electrocardiographic abnormalities in both overt and subclinical disease after adjustment for fibrosis and left ventricular hypertrophy (overt: fractional anisotropy: odds ratio for an abnormal ECG, 3.3, P=0.01; stress myocardial blood flow: odds ratio, 2.8, P=0.015; subclinical: fractional anisotropy odds ratio, 4.0, P=0.001; myocardial perfusion reserve odds ratio, 2.2, P=0.049). CONCLUSIONS: Microstructural alteration and MVD occur in overt HCM and are different in G+ and G- patients. Both also occur in the absence of hypertrophy in sarcomeric mutation carriers, in whom changes are associated with electrocardiographic abnormalities. Measurable changes in myocardial microstructure and microvascular function are early-phenotype biomarkers in the emerging era of disease-modifying therapy.


Subject(s)
Cardiomyopathy, Hypertrophic , Hypertrophy, Left Ventricular , Humans , Sarcomeres/genetics , Diffusion Tensor Imaging , Genetic Predisposition to Disease , Mutation , Cardiomyopathy, Hypertrophic/diagnosis , Phenotype , Biomarkers , Fibrosis
3.
Hum Genet ; 2024 Jul 06.
Article in English | MEDLINE | ID: mdl-38969939

ABSTRACT

An elevated resting heart rate (RHR) is associated with increased cardiovascular mortality. Genome-wide association studies (GWAS) have identified > 350 loci. Uniquely, in this study we applied genetic fine-mapping leveraging tissue specific chromatin segmentation and colocalization analyses to identify causal variants and candidate effector genes for RHR. We used RHR GWAS summary statistics from 388,237 individuals of European ancestry from UK Biobank and performed fine mapping using publicly available genomic annotation datasets. High-confidence causal variants (accounting for > 75% posterior probability) were identified, and we collated candidate effector genes using a multi-omics approach that combined evidence from colocalisation with molecular quantitative trait loci (QTLs), and long-range chromatin interaction analyses. Finally, we performed druggability analyses to investigate drug repurposing opportunities. The fine mapping pipeline indicated 442 distinct RHR signals. For 90 signals, a single variant was identified as a high-confidence causal variant, of which 22 were annotated as missense. In trait-relevant tissues, 39 signals colocalised with cis-expression QTLs (eQTLs), 3 with cis-protein QTLs (pQTLs), and 75 had promoter interactions via Hi-C. In total, 262 candidate genes were highlighted (79% had promoter interactions, 15% had a colocalised eQTL, 8% had a missense variant and 1% had a colocalised pQTL), and, for the first time, enrichment in nervous system pathways. Druggability analyses highlighted ACHE, CALCRL, MYT1 and TDP1 as potential targets. Our genetic fine-mapping pipeline prioritised 262 candidate genes for RHR that warrant further investigation in functional studies, and we provide potential therapeutic targets to reduce RHR and cardiovascular mortality.

4.
J Magn Reson Imaging ; 2024 Jul 09.
Article in English | MEDLINE | ID: mdl-38982805

ABSTRACT

BACKGROUND: Clinical importance of mitral annulus disjunction (MAD) is not well established. PURPOSE: Characterize a population of MAD all-comers diagnosed by cardiac magnetic resonance imaging (MRI). STUDY TYPE: Retrospective. POPULATION: MAD confirmed in 222 patients, age of 49.2 ± 19.3 years, 126 (56.8%) males. FIELD STRENGTH/SEQUENCE: 1.5 T and 3 T/steady-state free precession and inversion recovery. ASSESSMENT: Clinical history, outcomes, imaging, and arrhythmia data. MAD defined as a separation ≥2 mm between left ventricular myocardium and mitral annulus. Presence and pattern of late gadolinium enhancement (LGE) were analyzed. LGE in the papillary muscles and adjacent to MAD were identified as MAD related. Ventricular arrhythmias (VA) were grouped into non-sustained ventricular arrhythmias (NSVA) or sustained. Cardiovascular death assessed. STATISTICAL TESTS: Differences between baseline characteristics were compared. Univariate regression was used to investigate possible associations between ventricular arrhythmia and cardiovascular death with characteristics associated with the severity of MAD. A multivariable logistic regression included significant variables from the univariate analysis and was performed for MAD-related and global LGE. RESULTS: MAD extent 5.0 ± 2.6 mm. MV annulus expanded during systole for MAD ≥6 mm. Systolic expansion associated with prolapse, billowing, and curling. LGE present in 82 patients (36.9%). Twenty-three patients (10.4%) showed MAD-related LGE by three different observers. No association of LGE with MAD extent (P = 0.545) noted. Follow-up 4.1 ± 2.4 years. No sustained VA observed. In univariable analysis, NSVA was more prevalent in patients with MAD ≥6 mm (33.3% vs. 9.9%), but this was attenuated on multivariate analysis (P = 0.054). The presence of NSVA was associated with global LGE but not MAD-related LGE in isolation (P = 0.750). Three patients died of cardiovascular causes (1.4%) and none had MAD-related LGE. None died of sudden cardiac arrest. CONCLUSION: In patients referred for cardiac MRI, mitral valve dysfunction was associated with MAD severity. Scar was not related to the extent of MAD, but associated with NSVA. The risk of sustained arrhythmias and cardiovascular death was low in this population. EVIDENCE LEVEL: 4 TECHNICAL EFFICACY: Stage 2.

5.
Cochrane Database Syst Rev ; 6: CD013255, 2024 06 03.
Article in English | MEDLINE | ID: mdl-38828867

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) is the most frequent sustained arrhythmia. Cardioversion is a rhythm control strategy to restore normal/sinus rhythm, and can be achieved through drugs (pharmacological) or a synchronised electric shock (electrical cardioversion). OBJECTIVES: To assess the efficacy and safety of pharmacological and electrical cardioversion for atrial fibrillation (AF), atrial flutter and atrial tachycardias. SEARCH METHODS: We searched CENTRAL, MEDLINE, Embase, Conference Proceedings Citation Index-Science (CPCI-S) and three trials registers (ClinicalTrials.gov, WHO ICTRP and ISRCTN) on 14 February 2023. SELECTION CRITERIA: We included randomised controlled trials (RCTs) at the individual patient level. Patient populations were aged ≥ 18 years with AF of any type and duration, atrial flutter or other sustained related atrial arrhythmias, not occurring as a result of reversible causes. DATA COLLECTION AND ANALYSIS: We used standard Cochrane methodology to collect data and performed a network meta-analysis using the standard frequentist graph-theoretical approach using the netmeta package in R. We used GRADE to assess the quality of the evidence which we presented in our summary of findings with a judgement on certainty. We calculated differences using risk ratios (RR) and 95% confidence intervals (CI) as well as ranking treatments using a P value. We assessed clinical and statistical heterogeneity and split the networks for the primary outcome and acute procedural success, due to concerns about violating the transitivity assumption. MAIN RESULTS: We included 112 RCTs (139 records), from which we pooled data from 15,968 patients. The average age ranged from 47 to 72 years and the proportion of male patients ranged from 38% to 92%. Seventy-nine trials were considered to be at high risk of bias for at least one domain, 32 had no high risk of bias domains, but had at least one domain classified as uncertain risk, and one study was considered at low risk for all domains. For paroxysmal AF (35 trials), when compared to placebo, anteroapical (AA)/anteroposterior (AP) biphasic truncated exponential waveform (BTE) cardioversion (RR: 2.42; 95% CI 1.65 to 3.56), quinidine (RR: 2.23; 95% CI 1.49 to 3.34), ibutilide (RR: 2.00; 95% CI 1.28 to 3.12), propafenone (RR: 1.98; 95% CI 1.67 to 2.34), amiodarone (RR: 1.69; 95% CI 1.42 to 2.02), sotalol (RR: 1.58; 95% CI 1.08 to 2.31) and procainamide (RR: 1.49; 95% CI 1.13 to 1.97) likely result in a large increase in maintenance of sinus rhythm until hospital discharge or end of study follow-up (certainty of evidence: moderate). The effect size was larger for AA/AP incremental and was progressively smaller for the subsequent interventions. Despite low certainty of evidence, antazoline may result in a large increase (RR: 28.60; 95% CI 1.77 to 461.30) in this outcome. Similarly, low-certainty evidence suggests a large increase in this outcome for flecainide (RR: 2.17; 95% CI 1.68 to 2.79), vernakalant (RR: 2.13; 95% CI 1.52 to 2.99), and magnesium (RR: 1.73; 95% CI 0.79 to 3.79). For persistent AF (26 trials), one network was created for electrical cardioversion and showed that, when compared to AP BTE incremental energy with patches, AP BTE maximum energy with patches (RR 1.35, 95% CI 1.17 to 1.55) likely results in a large increase, and active compression AP BTE incremental energy with patches (RR: 1.14, 95% CI 1.00 to 1.131) likely results in an increase in maintenance of sinus rhythm at hospital discharge or end of study follow-up (certainty of evidence: high). Use of AP BTE incremental with paddles (RR: 1.03, 95% CI 0.98 to 1.09; certainty of evidence: low) may lead to a slight increase, and AP MDS Incremental paddles (RR: 0.95, 95% CI 0.86 to 1.05; certainty of evidence: low) may lead to a slight decrease in efficacy. On the other hand, AP MDS incremental energy using patches (RR: 0.78, 95% CI 0.70 to 0.87), AA RBW incremental energy with patches (RR: 0.76, 95% CI 0.66 to 0.88), AP RBW incremental energy with patches (RR: 0.76, 95% CI 0.68 to 0.86), AA MDS incremental energy with patches (RR: 0.76, 95% CI 0.67 to 0.86) and AA MDS incremental energy with paddles (RR: 0.68, 95% CI 0.53 to 0.83) probably result in a decrease in this outcome when compared to AP BTE incremental energy with patches (certainty of evidence: moderate). The network for pharmacological cardioversion showed that bepridil (RR: 2.29, 95% CI 1.26 to 4.17) and quindine (RR: 1.53, (95% CI 1.01 to 2.32) probably result in a large increase in maintenance of sinus rhythm at hospital discharge or end of study follow-up when compared to amiodarone (certainty of evidence: moderate). Dofetilide (RR: 0.79, 95% CI 0.56 to 1.44), sotalol (RR: 0.89, 95% CI 0.67 to 1.18), propafenone (RR: 0.79, 95% CI 0.50 to 1.25) and pilsicainide (RR: 0.39, 95% CI 0.02 to 7.01) may result in a reduction in this outcome when compared to amiodarone, but the certainty of evidence is low. For atrial flutter (14 trials), a network could be created only for antiarrhythmic drugs. Using placebo as the common comparator, ibutilide (RR: 21.45, 95% CI 4.41 to 104.37), propafenone (RR: 7.15, 95% CI 1.27 to 40.10), dofetilide (RR: 6.43, 95% CI 1.38 to 29.91), and sotalol (RR: 6.39, 95% CI 1.03 to 39.78) probably result in a large increase in the maintenance of sinus rhythm at hospital discharge or end of study follow-up (certainty of evidence: moderate), and procainamide (RR: 4.29, 95% CI 0.63 to 29.03), flecainide (RR 3.57, 95% CI 0.24 to 52.30) and vernakalant (RR: 1.18, 95% CI 0.05 to 27.37) may result in a large increase in maintenance of sinus rhythm at hospital discharge or end of study follow-up (certainty of evidence: low). All tested electrical cardioversion strategies for atrial flutter had very high efficacy (97.9% to 100%). The rate of mortality (14 deaths) and stroke or systemic embolism (3 events) at 30 days was extremely low. Data on quality of life were scarce and of uncertain clinical significance. No information was available regarding heart failure readmissions. Data on duration of hospitalisation was scarce, of low quality, and could not be pooled. AUTHORS' CONCLUSIONS: Despite the low quality of evidence, this systematic review provides important information on electrical and pharmacological strategies to help patients and physicians deal with AF and atrial flutter. In the assessment of the patient comorbidity profile, antiarrhythmic drug onset of action and side effect profile versus the need for a physician with experience in sedation, or anaesthetics support for electrical cardioversion are key aspects when choosing the cardioversion method.


Subject(s)
Anti-Arrhythmia Agents , Atrial Fibrillation , Atrial Flutter , Electric Countershock , Network Meta-Analysis , Randomized Controlled Trials as Topic , Aged , Humans , Middle Aged , Anti-Arrhythmia Agents/therapeutic use , Atrial Fibrillation/therapy , Atrial Fibrillation/drug therapy , Atrial Flutter/therapy , Bias , Tachycardia/therapy , Male , Female
6.
Circulation ; 145(5): 321-329, 2022 02.
Article in English | MEDLINE | ID: mdl-34779221

ABSTRACT

BACKGROUND: The PRAETORIAN trial (A Prospective, Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) showed noninferiority of subcutaneous implantable cardioverter defibrillator (S-ICD) compared with transvenous implantable cardioverter defibrillator (TV-ICD) with regard to inappropriate shocks and complications. In contrast to TV-ICD, S-ICD cannot provide antitachycardia pacing for monomorphic ventricular tachycardia. This prespecified secondary analysis evaluates appropriate therapy and whether antitachycardia pacing reduces the number of appropriate shocks. METHODS: The PRAETORIAN trial was an international, investigator-initiated randomized trial that included patients with an indication for implantable cardioverter defibrillator (ICD) therapy. Patients with previous ventricular tachycardia <170 bpm or refractory recurrent monomorphic ventricular tachycardia were excluded. In 39 centers, 849 patients were randomized to receive an S-ICD (n=426) or TV-ICD (n=423) and were followed for a median of 49.1 months. ICD programming was mandated by protocol. Appropriate ICD therapy was defined as therapy for ventricular arrhythmias. Arrhythmias were classified as discrete episodes and storm episodes (≥3 episodes within 24 hours). Analyses were performed in the modified intention-to-treat population. RESULTS: In the S-ICD group, 86 of 426 patients received appropriate therapy, versus 78 of 423 patients in the TV-ICD group, during a median follow-up of 52 months (48-month Kaplan-Meier estimates 19.4% and 17.5%; P=0.45). In the S-ICD group, 83 patients received at least 1 shock, versus 57 patients in the TV-ICD group (48-month Kaplan-Meier estimates 19.2% and 11.5%; P=0.02). Patients in the S-ICD group had a total of 254 shocks, compared with 228 shocks in the TV-ICD group (P=0.68). First shock efficacy was 93.8% in the S-ICD group and 91.6% in the TV-ICD group (P=0.40). The first antitachycardia pacing attempt successfully terminated 46% of all monomorphic ventricular tachycardias, but accelerated the arrhythmia in 9.4%. Ten patients with S-ICD experienced 13 electrical storms, versus 18 patients with TV-ICD with 19 electrical storms. Patients with appropriate therapy had an almost 2-fold increased relative risk of electrical storms in the TV-ICD group compared with the S-ICD group (P=0.05). CONCLUSIONS: In this trial, no difference was observed in shock efficacy of S-ICD compared with TV-ICD. Although patients in the S-ICD group were more likely to receive an ICD shock, the total number of appropriate shocks was not different between the 2 groups. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01296022.


Subject(s)
Arrhythmias, Cardiac/therapy , Defibrillators, Implantable/standards , Aged , Arrhythmias, Cardiac/diagnosis , Female , Humans , Male , Middle Aged , Prospective Studies , Treatment Outcome
7.
Hum Mol Genet ; 30(24): 2513-2523, 2021 11 30.
Article in English | MEDLINE | ID: mdl-34274964

ABSTRACT

The resting QT interval, an electrocardiographic (ECG) measure of ventricular myocardial repolarization, is a heritable risk marker of cardiovascular mortality, but the mechanisms remain incompletely understood. Previously reported candidate genes have provided insights into the regulatory mechanisms of the QT interval. However, there are still important knowledge gaps. We aimed to gain new insights by (i) providing new candidate genes, (ii) identifying pleiotropic associations with other cardiovascular traits, and (iii) scanning for sexually dimorphic genetic effects. We conducted a genome-wide association analysis for resting QT interval with ~9.8 million variants in 52 107 individuals of European ancestry without known cardiovascular disease from the UK Biobank. We identified 40 loci, 13 of which were novel, including 2 potential sex-specific loci, explaining ~11% of the trait variance. Candidate genes at novel loci were involved in myocardial structure and arrhythmogenic cardiomyopathy. Investigation of pleiotropic effects of QT interval variants using phenome-wide association analyses in 302 000 unrelated individuals from the UK Biobank and pairwise genome-wide comparisons with other ECG and cardiac imaging traits revealed genetic overlap with atrial electrical pathology. These findings provide novel insights into how abnormal myocardial repolarization and increased cardiovascular mortality may be linked.


Subject(s)
Genome-Wide Association Study , Polymorphism, Single Nucleotide , Electrocardiography , Female , Genome-Wide Association Study/methods , Genomics , Humans , Male , Phenotype , Polymorphism, Single Nucleotide/genetics
8.
Am J Hum Genet ; 106(6): 764-778, 2020 06 04.
Article in English | MEDLINE | ID: mdl-32386560

ABSTRACT

Sudden cardiac death is responsible for half of all deaths from cardiovascular disease. The analysis of the electrophysiological substrate for arrhythmias is crucial for optimal risk stratification. A prolonged T-peak-to-Tend (Tpe) interval on the electrocardiogram is an independent predictor of increased arrhythmic risk, and Tpe changes with heart rate are even stronger predictors. However, our understanding of the electrophysiological mechanisms supporting these risk factors is limited. We conducted genome-wide association studies (GWASs) for resting Tpe and Tpe response to exercise and recovery in ∼30,000 individuals, followed by replication in independent samples (∼42,000 for resting Tpe and ∼22,000 for Tpe response to exercise and recovery), all from UK Biobank. Fifteen and one single-nucleotide variants for resting Tpe and Tpe response to exercise, respectively, were formally replicated. In a full dataset GWAS, 13 further loci for resting Tpe, 1 for Tpe response to exercise and 1 for Tpe response to exercise were genome-wide significant (p ≤ 5 × 10-8). Sex-specific analyses indicated seven additional loci. In total, we identify 32 loci for resting Tpe, 3 for Tpe response to exercise and 3 for Tpe response to recovery modulating ventricular repolarization, as well as cardiac conduction and contraction. Our findings shed light on the genetic basis of resting Tpe and Tpe response to exercise and recovery, unveiling plausible candidate genes and biological mechanisms underlying ventricular excitability.


Subject(s)
Electrocardiography , Exercise/physiology , Genome-Wide Association Study , Ventricular Function/genetics , Adult , Aged , Female , Genetic Loci/genetics , Genetic Predisposition to Disease , Humans , Male , Middle Aged , Polymorphism, Single Nucleotide/genetics , Rest/physiology , Sex Characteristics , United Kingdom , Ventricular Function/physiology
9.
N Engl J Med ; 383(6): 526-536, 2020 08 06.
Article in English | MEDLINE | ID: mdl-32757521

ABSTRACT

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (ICD) was designed to avoid complications related to the transvenous ICD lead by using an entirely extrathoracic placement. Evidence comparing these systems has been based primarily on observational studies. METHODS: We conducted a noninferiority trial in which patients with an indication for an ICD but no indication for pacing were assigned to receive a subcutaneous ICD or transvenous ICD. The primary end point was the composite of device-related complications and inappropriate shocks; the noninferiority margin for the upper boundary of the 95% confidence interval for the hazard ratio (subcutaneous ICD vs. transvenous ICD) was 1.45. A superiority analysis was prespecified if noninferiority was established. Secondary end points included death and appropriate shocks. RESULTS: A total of 849 patients (426 in the subcutaneous ICD group and 423 in the transvenous ICD group) were included in the analyses. At a median follow-up of 49.1 months, a primary end-point event occurred in 68 patients in the subcutaneous ICD group and in 68 patients in the transvenous ICD group (48-month Kaplan-Meier estimated cumulative incidence, 15.1% and 15.7%, respectively; hazard ratio, 0.99; 95% confidence interval [CI], 0.71 to 1.39; P = 0.01 for noninferiority; P = 0.95 for superiority). Device-related complications occurred in 31 patients in the subcutaneous ICD group and in 44 in the transvenous ICD group (hazard ratio, 0.69; 95% CI, 0.44 to 1.09); inappropriate shocks occurred in 41 and 29 patients, respectively (hazard ratio, 1.43; 95% CI, 0.89 to 2.30). Death occurred in 83 patients in the subcutaneous ICD group and in 68 in the transvenous ICD group (hazard ratio, 1.23; 95% CI, 0.89 to 1.70); appropriate shocks occurred in 83 and 57 patients, respectively (hazard ratio, 1.52; 95% CI, 1.08 to 2.12). CONCLUSIONS: In patients with an indication for an ICD but no indication for pacing, the subcutaneous ICD was noninferior to the transvenous ICD with respect to device-related complications and inappropriate shocks. (Funded by Boston Scientific; PRAETORIAN ClinicalTrials.gov number, NCT01296022.).


Subject(s)
Arrhythmias, Cardiac/therapy , Defibrillators, Implantable/adverse effects , Aged , Cardiomyopathies/therapy , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/prevention & control , Electrodes, Implanted/adverse effects , Equipment Failure , Female , Follow-Up Studies , Heart Diseases/therapy , Humans , Incidence , Kaplan-Meier Estimate , Male , Middle Aged , Prosthesis Design
10.
J Cardiovasc Electrophysiol ; 34(11): 2330-2341, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37735956

ABSTRACT

Accessing the pericardial space safely and efficiently is an important skill for interventional cardiac electrophysiologist. With the increased recognition of the complexity of the 3-dimensional arrhythmogenic substrate due to advances in imaging and mapping technologies there has been an expansion of epicardial procedures in recent years. Equally, minimally invasive implantation of epicardial pacing, cardiac resynchronization, or defibrillation leads is expanding in specific patients where transvenous systems are contraindicated or their long term sequelae should be ideally avoided. Selective delivery of intrapericardial pharmacological antiarrhythmic therapy is yet another potential indication, albeit still investigational. The expanding indications for percutaneous epicardial procedures is contrasted by the still substantial risk and challenges associated with accessing the pericardial space. Myocardial perforation, coronary artery laceration, and damage to the surrounding organs are all recognized and feared complications. A number of innovative epicardial access techniques have been proposed to overcome the difficulties and risks of traditional dry subxiphoid punctures and may allow for more widespread use of epicardial access in the future. We review 10 different established and novel subxiphoidal epicardial access techniques describing procedural success rates, safety profile and overall experience. The technical aspects as well as access times and costs for extra equipment will be reviewed. Finally, an outlook of reported preclinical techniques awaiting in-human feasibility studies is provided.


Subject(s)
Catheter Ablation , Pericardium , Humans , Pericardium/surgery , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/surgery , Cardiac Electrophysiology , Catheter Ablation/adverse effects , Catheter Ablation/methods
11.
J Cardiovasc Electrophysiol ; 34(5): 1141-1151, 2023 05.
Article in English | MEDLINE | ID: mdl-36808788

ABSTRACT

INTRODUCTION: Preliminary data suggest that high power short duration (HPSD) ablation for pulmonary vein isolation (PVI) are safe. Limited data are available on its effectiveness. Aim was to evaluate HPSD ablation in atrial fibrillation ablation using a novel Qdot Micro catheter. METHODS AND RESULTS: Prospective multicenter study evaluating safety and efficacy of PVI with HPSD ablation. First pass isolation (FPI) and sustained PVI was assessed. If FPI was not achieved additional ablation index (AI)-guided ablation with 45 W was performed and metrics predictive of this were determined. Sixty-five patients and 260 veins were treated. Procedural and LA dwell time was 93.9 ± 30.4 and 60.5 ± 23.1 min, respectively. FPI was achieved in 47 (72.3%) patients and 231 veins (88.8%) with an ablation duration of 4.6 ± 1.0 min. Twenty-nine veins required additional AI-guided ablation to achieve initial PVI with 24 anatomical sites ablated with the right posterior carina being the most common site (37.5%). A contact force of ≥8 g (area under the curve [AUC]: 0.81; p < 0.001) and catheter position variation of ≤1.2 mm (AUC: 0.79; p < 0.001) with HPSD were strongly predictive of not requiring additional AI-guided ablation. Out of the 260 veins, only 5 (1.9%) veins showed acute reconnection. HPSD ablation was associated with shorter procedure times (93.9 vs. 159.4 min; p < 0.001), ablation times (6.1 vs. 27.7 min; p < 0.001), and lower rates of PV reconnection (9.2% vs. 30.8%; p = 0.004) compared to moderate power cohort. CONCLUSIONS: HPSD ablation is an effective ablation modality which results in effective PVI whilst maintaining a safety profile. Its superiority needs to be evaluated in randomized controlled trials.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/etiology , Heart Rate , Pulmonary Veins/surgery , Prospective Studies , Catheters , Catheter Ablation/adverse effects , Catheter Ablation/methods , Treatment Outcome , Recurrence
12.
J Cardiovasc Magn Reson ; 25(1): 73, 2023 Dec 04.
Article in English | MEDLINE | ID: mdl-38044439

ABSTRACT

BACKGROUND: Electrocardiographic imaging (ECGI) generates electrophysiological (EP) biomarkers while cardiovascular magnetic resonance (CMR) imaging provides data about myocardial structure, function and tissue substrate. Combining this information in one examination is desirable but requires an affordable, reusable, and high-throughput solution. We therefore developed the CMR-ECGI vest and carried out this technical development study to assess its feasibility and repeatability in vivo. METHODS: CMR was prospectively performed at 3T on participants after collecting surface potentials using the locally designed and fabricated 256-lead ECGI vest. Epicardial maps were reconstructed to generate local EP parameters such as activation time (AT), repolarization time (RT) and activation recovery intervals (ARI). 20 intra- and inter-observer and 8 scan re-scan repeatability tests. RESULTS: 77 participants were recruited: 27 young healthy volunteers (HV, 38.9 ± 8.5 years, 35% male) and 50 older persons (77.0 ± 0.1 years, 52% male). CMR-ECGI was achieved in all participants using the same reusable, washable vest without complications. Intra- and inter-observer variability was low (correlation coefficients [rs] across unipolar electrograms = 0.99 and 0.98 respectively) and scan re-scan repeatability was high (rs between 0.81 and 0.93). Compared to young HV, older persons had significantly longer RT (296.8 vs 289.3 ms, p = 0.002), ARI (249.8 vs 235.1 ms, p = 0.002) and local gradients of AT, RT and ARI (0.40 vs 0.34 ms/mm, p = 0,01; 0.92 vs 0.77 ms/mm, p = 0.03; and 1.12 vs 0.92 ms/mm, p = 0.01 respectively). CONCLUSION: Our high-throughput CMR-ECGI solution is feasible and shows good reproducibility in younger and older participants. This new technology is now scalable for high throughput research to provide novel insights into arrhythmogenesis and potentially pave the way for more personalised risk stratification. CLINICAL TRIAL REGISTRATION: Title: Multimorbidity Life-Course Approach to Myocardial Health-A Cardiac Sub-Study of the MRC National Survey of Health and Development (NSHD) (MyoFit46). National Clinical Trials (NCT) number: NCT05455125. URL: https://clinicaltrials.gov/ct2/show/NCT05455125?term=MyoFit&draw=2&rank=1.


Subject(s)
Heart , Magnetic Resonance Imaging , Aged , Female , Humans , Male , Feasibility Studies , Magnetic Resonance Imaging/methods , Magnetic Resonance Spectroscopy , Predictive Value of Tests , Reproducibility of Results , Adult , Middle Aged
13.
Europace ; 25(2): 351-359, 2023 02 16.
Article in English | MEDLINE | ID: mdl-36106534

ABSTRACT

AIMS: Utilizing real-world UK data, we aimed to understand: (i) whether anti-arrhythmic drugs and catheter ablation are effective in improving the survival of atrial fibrillation (AF) patients and (ii) which rhythm control option produces better results for the whole AF population and for specific groups of patients, stratified by age, sex, and history of heart failure. METHODS AND RESULTS: We identified 199 433 individuals (mean age at diagnosis 75.7 ± 12.7 years; 50.2% women) with new-onset AF diagnosis in nationwide electronic health records linking primary care consultation with hospital data and death registry data from 1998 to 2016. We investigated the survival and causes of death of new-onset AF patients receiving vs. not-receiving rhythm control therapies. During a median follow-up of 2.7 (0.7-6.0) years, we observed a significantly lower mortality in patients receiving rhythm control [multivariate-adjusted hazard ratio (HR) = 0.86, 95% confidence interval (CI) 0.84-0.88]. Pulmonary vein isolation was associated with a two-third significant mortality reduction compared with no rhythm control (HR = 0.36, 95% CI 0.28-0.48), flecainide with 50% reduction (HR = 0.52, 95% CI 0.48-0.57), and propafenone and sotalol with reduction by a third (HR = 0.63, 95% CI 0.50-0.81, 0.71, 95% CI 0.68-0.74, respectively). Amiodarone showed no survival benefit in individuals <70 years (HR = 0.99, 95% CI 0.97-1.02). Otherwise, the effect of rhythm control on survival did not differ by age, sex, nor history of heart failure. CONCLUSION: Among individuals with new-onset AF, favourable survival was observed for patients receiving rhythm control treatment. Among different rhythm control strategies, pulmonary vein isolation showed the most pronounced survival benefit.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Heart Failure , Humans , Female , Middle Aged , Aged , Aged, 80 and over , Male , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/complications , Anti-Arrhythmia Agents/therapeutic use , Heart Failure/diagnosis , Heart Failure/therapy , Heart Failure/complications , Catheter Ablation/adverse effects , United Kingdom/epidemiology , Treatment Outcome
14.
Europace ; 25(5)2023 05 19.
Article in English | MEDLINE | ID: mdl-37213071

ABSTRACT

AIMS: Arrhythmogenic right ventricular cardiomyopathy (ARVC) patients develop ventricular arrhythmias (VAs) responsive to anti-tachycardia pacing (ATP). However, VA episodes have not been characterized in accordance with the device therapy, and with the emergence of the subcutaneous implantable cardioverter defibrillator (S-ICD), the appropriate device prescription in ARVC remains unclear. Study aim was to characterize VA events in ARVC patients during follow-up in accordance with device therapy and elicit if certain parameters are predictive of specific VA events. METHODS AND RESULTS: This was a retrospective single-centre study utilizing prospectively collated registry data of ARVC patients with ICDs. Forty-six patients were included [54.0 ± 12.1 years old and 20 (43.5%) secondary prevention devices]. During a follow-up of 12.1 ± 6.9 years, 31 (67.4%) patients had VA events [n = 2, 6.5% ventricular fibrillation (VF), n = 14], 45.2% VT falling in VF zone resulting in ICD shock(s), n = 10, 32.3% VT resulting in ATP, and n = 5, 16.1% patients had both VT resulting in ATP and ICD shock(s). Lead failure rates were high (11/46, 23.9%). ATP was successful in 34.5% of patients. Severely impaired right ventricular (RV) function was an independent predictor of VT resulting in ATP (hazard ratio 16.80, 95% confidence interval 3.74-75.2; P < 0.001) with a high predictive accuracy (area under the curve 0.88, 95%CI 0.76-1.00; P < 0.001). CONCLUSION: VA event rates are high in ARVC patients with a majority having VT falling in the VF zone resulting in ICD shock(s). S-ICDs could be of benefit in most patients with ARVC with the absence of severely impaired RV function which has the potential to avoid consequences of the high burden of lead failure.


Subject(s)
Arrhythmogenic Right Ventricular Dysplasia , Cardiomyopathies , Defibrillators, Implantable , Tachycardia, Ventricular , Humans , Adult , Middle Aged , Aged , Defibrillators, Implantable/adverse effects , Retrospective Studies , Ventricular Function, Right , Follow-Up Studies , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/prevention & control , Ventricular Fibrillation/diagnosis , Ventricular Fibrillation/prevention & control , Arrhythmias, Cardiac/etiology , Cardiomyopathies/complications , Adenosine Triphosphate , Arrhythmogenic Right Ventricular Dysplasia/complications , Arrhythmogenic Right Ventricular Dysplasia/diagnosis , Arrhythmogenic Right Ventricular Dysplasia/therapy
15.
Europace ; 25(2): 536-545, 2023 02 16.
Article in English | MEDLINE | ID: mdl-36480445

ABSTRACT

AIMS: Cardiac resynchronization therapy programmed to dynamically fuse pacing with intrinsic conduction using atrioventricular (AV) timing algorithms (e.g. SyncAV) has shown promise; however, mechanistic data are lacking. This study assessed the impact of SyncAV on electrical dyssynchrony across various pacing modalities using non-invasive epicardial electrocardiographic imaging (ECGi). METHODS AND RESULTS: Twenty-five patients with left bundle-branch block (median QRS duration (QRSd) 162.7 ms) and intact AV conduction (PR interval 174.0 ms) were prospectively enrolled. ECGi was performed acutely during biventricular pacing with fixed nominal AV delays (BiV) and using SyncAV (optimized for the narrowest QRSd) during: BiV + SyncAV, LV-only single-site (LVSS + SyncAV), MultiPoint pacing (MPP + SyncAV), and LV-only MPP (LVMPP + SyncAV). Dyssynchrony was quantified via ECGi (LV activation time, LVAT; RV activation time, RVAT; LV electrical dispersion index, LVEDi; ventricular electrical uncoupling index, VEU; and biventricular total activation time, VVtat). Intrinsic conduction LVAT (124 ms) was significantly reduced by BiV pacing (109 ms) (P = 0.001) and further reduced by LVSS + SyncAV (103 ms), BiV + SyncAV (103 ms), LVMPP + SyncAV (95 ms), and MPP + SyncAV (90 ms). Intrinsic RVAT (93 ms), VVtat (130 ms), LVEDi (36 ms), VEU (50 ms), and QRSd (163 ms) were reduced by SyncAV across all pacing modes. More patients exhibited minimal LVAT, VVtat, LVEDi, and QRSd with MPP + SyncAV than any other modality. CONCLUSION: Dynamic AV delay programming targeting fusion with intrinsic conduction significantly reduced dyssynchrony, as quantified by ECGi and QRSd for all evaluated pacing modes. MPP + SyncAV achieved the greatest synchrony overall but not for all patients, highlighting the value of pacing mode individualization during fusion optimization.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Humans , Bundle-Branch Block/diagnostic imaging , Bundle-Branch Block/therapy , Heart Failure/therapy , Cardiac Resynchronization Therapy/methods , Electrocardiography , Cardiac Resynchronization Therapy Devices , Treatment Outcome
16.
Europace ; 25(5)2023 05 19.
Article in English | MEDLINE | ID: mdl-37001913

ABSTRACT

AIMS: The SMART Pass™ (SP) algorithm is a high-pass filter that aims to reduce inappropriate therapy (IT) in subcutaneous internal cardiac defibrillator (S-ICD), but SP can deactivate due to low amplitude sensed R waves or asystole. The association between IT and SP deactivation and management strategies were evaluated, hypothesizing SP deactivation increases the risk of IT and device re-programming, or lead/generator re-positioning could reduce this risk. METHODS AND RESULTS: Retrospective single-centre audit of Emblem™ S-ICD devices implanted 2016 to 2020 utilizing health records and remote monitoring data. Cox regression models evaluated associations between SP deactivation and IT. A total of 348 patients (27 ± 16.6 months follow-up) were studied: 73% primary prevention. Thirty-eight patients (11.8%) received 83 shocks with 27 patients (7.8%) receiving a total of 44 IT. Causes of IT were oversensing (98%) and aberrantly conducted atrial fibrillation (2%). SP deactivation occurred in 32 of 348 patients (9%) and was significantly associated with increased risk of IT (hazard ratio 5.36, 95% CI 2.37-12.13). SP deactivation was due to low amplitude R waves (94%), associated with a higher defibrillation threshold at implant and presence of arrhythmogenic right ventricular cardiomyopathy. No further IT occurred 16 ± 15.5 months after corrective interventions, with changing the sensing vector being successful in 59% of cases. CONCLUSION: To reduce the risk of IT, the cause of the SP deactivation should be investigated, and appropriate reprogramming, device, or lead modifications made. Utilizing the alert for SP deactivation and electrograms could pro-actively prevent IT.


Subject(s)
Arrhythmogenic Right Ventricular Dysplasia , Atrial Fibrillation , Defibrillators, Implantable , Humans , Defibrillators, Implantable/adverse effects , Retrospective Studies , Electric Countershock , Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Atrial Fibrillation/etiology , Arrhythmogenic Right Ventricular Dysplasia/therapy
17.
Cochrane Database Syst Rev ; 3: CD013765, 2023 03 13.
Article in English | MEDLINE | ID: mdl-36915032

ABSTRACT

BACKGROUND: Recurrence of atrial tachyarrhythmias (ATa) following catheter ablation for atrial fibrillation (AF) is a common problem. Antiarrhythmic drugs have been used shortly after ablation in an attempt to maintain sinus rhythm, particularly Class I and III agents. However, it still needs to be established if the use of Class I or III antiarrhythmic medications, or both, reduce the risk of recurrence of ATa. OBJECTIVES: To assess the effects of oral Class I and III antiarrhythmic drugs versus control (standard medical therapy without Class I or III antiarrhythmics, or placebo) for maintaining sinus rhythm in people undergoing catheter ablation for AF. SEARCH METHODS: We systematically searched CENTRAL, MEDLINE, Embase, Web of Science Core Collection, and two clinical trial registers without restrictions on language or date to 5 August 2022. SELECTION CRITERIA: We sought published, unpublished, and ongoing parallel-design, randomised controlled trials (RCTs) involving adult participants undergoing ablation for AF, with subsequent comparison of Class I and/or III antiarrhythmic use versus control (standard medical therapy or non-Class I and/or III antiarrhythmic use). DATA COLLECTION AND ANALYSIS: We used standard methodological procedures expected by Cochrane and performed meta-analyses with risk ratios (RR) and Peto odds ratios (Peto OR). Our primary outcomes were recurrence of atrial tachyarrhythmias; adverse events: thromboembolic events; adverse events: myocardial infarction; adverse events: new diagnosis of heart failure; and adverse events: requirement for one or more hospitalisations for atrial tachyarrhythmia. Our secondary outcomes were: all-cause mortality; and requirement for one or more repeat ablations. Where possible, we performed comparison analysis by Class I and/or III antiarrhythmic and divided follow-up periods for our primary outcome. We performed comprehensive assessments of risk of bias and certainty of evidence applying the GRADE methodology. MAIN RESULTS: We included nine RCTs involving a total of 3269 participants. Participants were on average 59.3 years old; 71.0% were male; and 72.9% and 27.4% had paroxysmal and persistent AF, respectively. Class I and/or III antiarrhythmics may reduce recurrence of ATa at 0 to 3 months postablation (risk ratio (RR) 0.74, 95% confidence interval (CI) 0.59 to 0.94, 8 trials, 3046 participants, low-certainty evidence) and likely reduce recurrence at > 3 to 6 months, our a priori primary time point (RR 0.85, 95% CI 0.78 to 0.93, 5 trials, 2591 participants, moderate-certainty evidence). Beyond six months the evidence is very uncertain, and the benefit of antiarrhythmics may not persist (RR 1.14, 95% CI 0.84 to 1.55, 4 trials, 2244 participants, very low-certainty evidence). The evidence suggests that Class I and/or III antiarrhythmics may not increase the risk of thromboembolic events, myocardial infarction, all-cause mortality, or requirement for repeat ablation, at 0 to 3, > 3 to 6, and > 6 months (where data were available; low- to very low-certainty evidence). The use of Class I and/or III antiarrhythmics postablation likely reduces hospitalisations for ATa by approximately 57% at 0 to 3 months (RR 0.43, 95% CI 0.28 to 0.64, moderate-certainty evidence). No data were available beyond three months. No data were available on new diagnoses of heart failure. Fewer data were available for Class I and III antiarrhythmics individually. Based on only one and two trials (n = 125 to 309), Class I antiarrhythmics may have little effect on recurrence of ATa at 0 to 3, > 3 to 6, and > 6 months (RR 0.88, 95% CI 0.64 to 1.20, 2 trials, 309 participants; RR 0.54, 95% CI 0.25 to 1.19, 1 trial, 125 participants; RR 0.87, 95% CI 0.57 to 1.32, 1 trial, 125 participants; low-certainty evidence throughout); requirement for hospitalisation for ATa at 0 to 3 months (low-certainty evidence); or requirement for repeat ablation at 0 to 3 months (low-certainty evidence). No data were available for thromboembolic events, myocardial infarction, new diagnosis of heart failure, or all-cause mortality at any time points, or hospitalisation or repeat ablation beyond three months. Class III antiarrhythmics may have little effect on recurrence of ATa at up to 3 months and at > 3 to 6 months (RR 0.76, 95% CI 0.50 to 1.16, 4 trials, 599 participants, low-certainty evidence; RR 0.82, 95% CI 0.62 to 1.09, 2 trials, 318 participants, low-certainty evidence), and beyond 6 months one trial reported a possible increase in recurrence of ATa (RR 1.95, 95% CI 1.29 to 2.94, 1 trial, 112 participants, low-certainty evidence). Class III antiarrhythmics likely reduce hospitalisations for ATa at 0 to 3 months (RR 0.40, 95% CI 0.26 to 0.63, moderate-certainty evidence), and may have little effect on all-cause mortality (low- to very low-certainty evidence). The effect of Class III antiarrhythmics on thromboembolic events and requirement for repeat ablation was uncertain (very low-certainty evidence for both outcomes). No data were available for myocardial infarction or new diagnosis of heart failure at any time point, outcomes other than recurrence beyond 6 months, or for hospitalisation and repeat ablation > 3 to 6 months. We assessed the majority of included trials as at low or unclear risk of bias. One trial reported an error in the randomisation process, raising the potential risk of selection bias; most of the included trials were non-blinded; and two trials were at high risk of attrition bias. AUTHORS' CONCLUSIONS: We found evidence to suggest that the use of Class I and/or III antiarrhythmics up to 3 months after ablation is associated with a reduced recurrence of ATa 0 to 6 months after ablation, which may not persist beyond 6 months, and an immediate reduction in hospitalisation for ATa 0 to 3 months after ablation. The evidence suggests there is no difference in rates of all-cause mortality, thromboembolic events, or myocardial infarction between Class I and/or III antiarrhythmics versus control.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Heart Failure , Myocardial Infarction , Adult , Female , Humans , Male , Middle Aged , Anti-Arrhythmia Agents/adverse effects , Atrial Fibrillation/drug therapy , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Heart Failure/drug therapy
18.
Eur Heart J ; 43(26): 2469-2478, 2022 07 07.
Article in English | MEDLINE | ID: mdl-34435642

ABSTRACT

AIMS: Many cardiac pacemakers and defibrillators are not approved by regulators for magnetic resonance imaging (MRI). Even following generator exchange to an approved magnetic resonance (MR)-conditional model, many systems remain classified 'non-MR conditional' due to the leads. This classification makes patient access to MRI challenging, but there is no evidence of increased clinical risk. We compared the effect of MRI on non-MR conditional and MR-conditional pacemaker and defibrillator leads. METHODS AND RESULTS: Patients undergoing clinical 1.5T MRI with pacemakers and defibrillators in three centres over 5 years were included. Magnetic resonance imaging protocols were similar for MR-conditional and non-MR conditional systems. Devices were interrogated pre- and immediately post-scan, and at follow-up, and adverse clinical events recorded. Lead parameter changes peri-scan were stratified by MR-conditional labelling. A total of 1148 MRI examinations were performed in 970 patients (54% non-MR conditional systems, 39% defibrillators, 15% pacing-dependent) with 2268 leads. There were no lead-related adverse clinical events, and no clinically significant immediate or late lead parameter changes following MRI in either MR-conditional or non-MR conditional leads. Small reductions in atrial and right ventricular sensed amplitudes and impedances were similar between groups, with no difference in the proportion of leads with parameter changes greater than pre-defined thresholds (7.1%, 95% confidence interval: 6.1-8.3). CONCLUSIONS: There was no increased risk of MRI in patients with non-MR conditional pacemaker or defibrillator leads when following recommended protocols. Standardizing MR conditions for all leads would significantly improve access to MRI by enabling patients to be scanned in non-specialist centres, with no discernible incremental risk.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Electronics , Humans , Magnetic Resonance Imaging/adverse effects , Magnetic Resonance Spectroscopy
19.
Eur Heart J ; 43(21): 2037-2050, 2022 06 01.
Article in English | MEDLINE | ID: mdl-35090007

ABSTRACT

AIMS: To report 5-year outcomes of EFFORTLESS registry patients with early generation subcutaneous implantable cardioverter-defibrillator (S-ICD) devices. METHODS AND RESULTS: Kaplan-Meier, trend and multivariable analyses were performed for mortality and late (years 2-5) complications, appropriate shock (AS) and inappropriate shock (IAS) rates. Nine hundred and eighty-four of 994 enrolled patients with diverse diagnoses (28% female, 48 ± 17 years, body mass index 27 ± 6 kg/m2, ejection fraction 43 ± 18%) underwent S-ICD implantation. Median follow-up was 5.1 years (interquartile range 4.7-5.5 years). All-cause mortality was 9.3% (95% confidence interval 7.2-11.3%) at 5 years; 703 patients remained in follow-up on study completion, 171 withdrew including 87 (8.8%) with device explanted, and 65 (6.6%) lost to follow-up. Of the explants, only 20 (2.0%) patients needed a transvenous device for pacing indications. First and final shock efficacy for discrete ventricular arrhythmias was consistent at 90% and 98%, respectively, with storm episode final shock efficacy at 95.2%. Time to therapy remained unaltered. Overall 1- and 5-year complication rates were 8.9% and 15.2%, respectively. Early complications did not predict later complications. There were no structural lead failures. Inappropriate shock rates at 1 and 5 years were 8.7% and 16.9%, respectively. Self-terminating inappropriately sensed episodes predicted late IAS. Predictors of late AS included self-terminating appropriately sensed episodes and earlier AS. CONCLUSION: In this diverse S-ICD registry population, spontaneous shock efficacy was consistently high over 5 years. Very few patients underwent S-ICD replacement with a transvenous device for pacing indications. Treated and self-terminating arrhythmic episodes predict future shock events, which should encourage more personalized device optimization.


Subject(s)
Defibrillators, Implantable , Arrhythmias, Cardiac , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable/adverse effects , Female , Follow-Up Studies , Humans , Male , Stroke Volume , Treatment Outcome
20.
Eur Heart J ; 43(47): 4872-4883, 2022 12 14.
Article in English | MEDLINE | ID: mdl-36030464

ABSTRACT

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) is developed to overcome lead-related complications and systemic infections, inherent to transvenous ICD (TV-ICD) therapy. The PRAETORIAN trial demonstrated that the S-ICD is non-inferior to the TV-ICD with regard to the combined primary endpoint of inappropriate shocks and complications. This prespecified secondary analysis evaluates all complications in the PRAETORIAN trial. METHODS AND RESULTS: The PRAETORIAN trial is an international, multicentre, randomized trial in which 849 patients with an indication for ICD therapy were randomized to receive an S- ICD (N = 426) or TV-ICD (N = 423) and followed for a median of 49 months. Endpoints were device-related complications, lead-related complications, systemic infections, and the need for invasive interventions. Thirty-six device-related complications occurred in 31 patients in the S-ICD group of which bleedings were the most frequent. In the TV-ICD group, 49 complications occurred in 44 patients of which lead dysfunction was most frequent (HR: 0.69; P = 0.11). In both groups, half of all complications were within 30 days after implantation. Lead-related complications and systemic infections occurred significantly less in the S-ICD group compared with the TV-ICD group (P < 0.001, P = 0.03, respectively). Significantly more complications required invasive interventions in the TV-ICD group compared with the S-ICD group (8.3% vs. 4.3%, HR: 0.59; P = 0.047). CONCLUSION: This secondary analysis shows that lead-related complications and systemic infections are more prevalent in the TV-ICD group compared with the S-ICD group. In addition, complications in the TV-ICD group were more severe as they required significantly more invasive interventions. This data contributes to shared decision-making in clinical practice.


Subject(s)
Death, Sudden, Cardiac , Defibrillators, Implantable , Humans , Treatment Outcome , Defibrillators, Implantable/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL