Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 59
Filter
1.
Circulation ; 144(19): 1543-1552, 2021 11 09.
Article in English | MEDLINE | ID: mdl-34459659

ABSTRACT

BACKGROUND: Percutaneous closure of the left atrial appendage (LAA) is an alternative to chronic oral anticoagulation to reduce stroke risk in patients with nonvalvular atrial fibrillation. The Amulet IDE trial (Amplatzer Amulet Left Atrial Appendage Occluder IDE Trial) was designed to evaluate the safety and effectiveness of the dual-seal mechanism of the Amulet LAA occluder compared with the Watchman device. METHODS: Patients with nonvalvular atrial fibrillation at increased risk of stroke were randomly assigned (1:1) to undergo percutaneous implantation of a LAA occluder with the Amulet occluder or Watchman device. The primary end points included safety (composite of procedure-related complications, all-cause death, or major bleeding at 12 months), effectiveness (composite of ischemic stroke or systemic embolism at 18 months), and the rate of LAA occlusion at 45 days. Prespecified secondary end points included a composite of all stroke, systemic embolism, or cardiovascular/unexplained death at 18 months, major bleeding at 18 months, and superiority test of the 3 primary end points. RESULTS: A total of 1878 patients were enrolled. The Amulet occluder was noninferior to the Watchman device for the primary safety end point (14.5% versus 14.7%; difference=-0.14 [95% CI, -3.42 to 3.13]; P<0.001 for noninferiority). Major bleeding and all-cause death were similar between groups (10.6% versus 10.0% and 3.9% versus 5.1%, respectively). Procedure-related complications were higher for the Amulet occluder (4.5% versus 2.5%), largely related to more frequent pericardial effusion and device embolization. The Amulet occluder was noninferior to the Watchman device for the primary effectiveness end point (2.8% versus 2.8%; difference=0.00 [95% CI, -1.55 to 1.55]; P<0.001 for noninferiority), and the composite of stroke, systemic embolism, or cardiovascular/unexplained death (5.6% versus 7.7%, difference=-2.12 [95% CI, -4.45 to 0.21]; P<0.001 for noninferiority). The rate of major bleeding was similar between groups (11.6% versus 12.3%; difference=-0.71 [95% CI, -3.72 to 2.31]; P=0.32 for superiority). LAA occlusion was higher for the Amulet occluder than for the Watchman device (98.9% versus 96.8%; difference=2.03 [95% CI, 0.41-3.66]; P<0.001 for noninferiority; P=0.003 for superiority). CONCLUSIONS: The Amulet occluder was noninferior for safety and effectiveness of stroke prevention for nonvalvular atrial fibrillation compared with the Watchman device and superior for LAA occlusion. Procedure-related complications were higher with the Amulet occluder and decreased with operator experience. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02879448.


Subject(s)
Septal Occluder Device/standards , Stroke/therapy , Aged , Female , Humans , Male
2.
Catheter Cardiovasc Interv ; 99(2): 405-410, 2022 02.
Article in English | MEDLINE | ID: mdl-33876860

ABSTRACT

BACKGROUND: There is limited data on complications associated with the use of coronary embolic protection devices (EPDs). METHODS: We queried the Manufacturer and User Facility Device Experience database between November 2010 and November 2020 for reports on coronary EPDs: Spider FX (Medtronic, Minneapolis, MN) and Filterwire EZ (Boston Scientific, Natick, MA). RESULTS: We retrieved 119 reports on coronary EPD failure (Spider FX n = 33 and Filterwire EZ n = 86), most of which (78.2%) occurred during saphenous vein graft interventions. The most common failure mode was inability to retrieve the EPD (49.6%), with the filter trapped against stent struts in 76.2% of the cases. Other device complications included filter fracture (28.6%), failure to cross (7.6%), failure to deploy (7.6%), and failure to recapture the filter (3.4%). Filter fracture (54.5 vs. 29.1%) and failure to recapture (9.1 vs. 2.1%) were more commonly reported, while failure to deploy the filter (0 vs. 10.5%) was less commonly reported with the Spider-FX. CONCLUSIONS: The most common modes of failure of coronary EPDs are the failure of retrieval (49.6%), followed by the filter fracture (28.6%). When using EPDs, careful attention to the technique is essential to avoid failures and subsequent complications.


Subject(s)
Embolic Protection Devices , Embolism , Embolism/etiology , Humans , Saphenous Vein/transplantation , Stents/adverse effects , Treatment Outcome
3.
Catheter Cardiovasc Interv ; 99(5): 1572-1581, 2022 04.
Article in English | MEDLINE | ID: mdl-35066997

ABSTRACT

BACKGROUND: Transesophageal echocardiogram (TEE) is the preferred imaging modality to guide transcatheter left atrial appendage closure (LAAC). Intracardiac echocardiography (ICE) has evolved as a less invasive alternative to TEE. Several observational studies have shown similar success rates and perioperative complications between TEE and ICE for LAAC. OBJECTIVES: We sought to examine the temporal trends and patient characteristics of TEE versus ICE use in LAAC using a national database. We also evaluated hospital outcomes including periprocedural complications, mortality, and length of hospital stay. METHODS: This is a retrospective analysis of data from the National Readmission Database, collected from 2016 to 2018. The primary outcome was major adverse events (MAE) defined as in-hospital mortality, cardiac arrest, pericardial effusion with or without tamponade, pericardiocentesis or window pericardiocentesis and pericardial window, pericardial effusion and tamponade, and hemorrhage requiring transfusion. RESULTS: Trend analysis showed that TEE-guided LAAC increased from 96.6% in 2016 to 98.4% in 2018 (relative increase, 1.9%), while ICE-guided LAAC decreased from 3.4% to 1.6% during the same period (relative decrease, 53%, p for trend = 0.08). In the unmatched cohorts, the MAE was significantly lower in TEE-guided LAAC compared to ICE-guided LAAC (6.5% vs. 9.3%, p = 0.022). In the propensity score matching analysis, MAE remained significant (5.6% vs. 9.4%, p < 0.001). The incidence of pericardial effusion with or without tamponade remained significantly lower in the TEE group (2.3% vs. 5.8%, p < 0.001). Length of stay (3.4 vs. 1.9 days, p < 0.001) and hospitalization cost ($34,826 vs. $20,563, p < 0.001) remained significantly lower for TEE-guided LAAC. CONCLUSIONS: Compared to ICE, the incidence of MAE was significantly lower for TEE-guided LAAC, driven mainly by less pericardial effusion events. Large-scale randomized trials are needed to confirm the findings of the current and previous studies.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Pericardial Effusion , Atrial Fibrillation/complications , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/therapy , Cardiac Catheterization/adverse effects , Cardiac Catheterization/methods , Echocardiography, Transesophageal , Hospitals , Humans , Pericardial Effusion/complications , Pericardial Effusion/etiology , Retrospective Studies , Treatment Outcome
4.
Catheter Cardiovasc Interv ; 98(6): E855-E861, 2021 11 15.
Article in English | MEDLINE | ID: mdl-33932271

ABSTRACT

BACKGROUND: There is a paucity of literature on safety and efficacy of various transseptal puncture (TSP) needles. OBJECTIVES: To assess the reported mechanisms of failure, complications, and outcomes among the most frequently used transseptal needles in the United States. METHODS: We queried the Food and Drug Administration (FDA) Manufacturer and User Facility Device Experience (MAUDE) database between January 2011 and January 2021 for reports on the most commonly used transseptal needles: NRG (Baylis Medical, Montreal, Canada), and BRK (St. Jude, Saint Paul, MN)]. The primary outcome was the mechanism of failure. Secondary outcomes included clinical consequences of device failure. RESULTS: The final analysis included 306 reports of failure/complication with TSP needles (NRG n = 70, BRK n = 236). The most commonly reported mode of failure was detachment of the needle component (i.e., clip, hub, stopcock, shaft, spring, or needle tip) (14.7% overall; 17.8% BRK; and 4.3% NRG). Among these reports, cardiac perforation was the most common complication (69.9% overall; 69.1% for BRK; and 72.9% for NRG). Pericardiocentesis was the second most commonly reported complication (45.1% overall; 48.3% for BRK; and 34.3% for NRG). The procedure was successfully completed in 33.3% of all cases (36.4% for BRK and 22.9% for NRG), while surgical conversion was needed in (13.4% overall; 14% for BRK and 11.4% for NRG) of the reports. Death occurred in 3.9% of all cases overall (3.4% for BRK and 5.7% for NRG). CONCLUSIONS: Needle detachment was the most common mode of failure, and cardiac perforation was the most common complication reported with TSP needles. Future efforts should focus on innovative TSP needle design, best practice guidelines, including role of imaging guidance, and increased TSP training.


Subject(s)
Catheter Ablation , Humans , Needles , Punctures , Treatment Outcome , United States , United States Food and Drug Administration
5.
N Engl J Med ; 376(14): 1321-1331, 2017 04 06.
Article in English | MEDLINE | ID: mdl-28304219

ABSTRACT

BACKGROUND: Although transcatheter aortic-valve replacement (TAVR) is an accepted alternative to surgery in patients with severe aortic stenosis who are at high surgical risk, less is known about comparative outcomes among patients with aortic stenosis who are at intermediate surgical risk. METHODS: We evaluated the clinical outcomes in intermediate-risk patients with severe, symptomatic aortic stenosis in a randomized trial comparing TAVR (performed with the use of a self-expanding prosthesis) with surgical aortic-valve replacement. The primary end point was a composite of death from any cause or disabling stroke at 24 months in patients undergoing attempted aortic-valve replacement. We used Bayesian analytical methods (with a margin of 0.07) to evaluate the noninferiority of TAVR as compared with surgical valve replacement. RESULTS: A total of 1746 patients underwent randomization at 87 centers. Of these patients, 1660 underwent an attempted TAVR or surgical procedure. The mean (±SD) age of the patients was 79.8±6.2 years, and all were at intermediate risk for surgery (Society of Thoracic Surgeons Predicted Risk of Mortality, 4.5±1.6%). At 24 months, the estimated incidence of the primary end point was 12.6% in the TAVR group and 14.0% in the surgery group (95% credible interval [Bayesian analysis] for difference, -5.2 to 2.3%; posterior probability of noninferiority, >0.999). Surgery was associated with higher rates of acute kidney injury, atrial fibrillation, and transfusion requirements, whereas TAVR had higher rates of residual aortic regurgitation and need for pacemaker implantation. TAVR resulted in lower mean gradients and larger aortic-valve areas than surgery. Structural valve deterioration at 24 months did not occur in either group. CONCLUSIONS: TAVR was a noninferior alternative to surgery in patients with severe aortic stenosis at intermediate surgical risk, with a different pattern of adverse events associated with each procedure. (Funded by Medtronic; SURTAVI ClinicalTrials.gov number, NCT01586910 .).


Subject(s)
Aortic Valve Stenosis/surgery , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve Stenosis/mortality , Bayes Theorem , Female , Heart Valve Prosthesis Implantation/adverse effects , Humans , Male , Postoperative Complications , Risk Factors , Severity of Illness Index , Stroke/epidemiology , Transcatheter Aortic Valve Replacement/adverse effects
6.
Circulation ; 138(9): 874-885, 2018 08 28.
Article in English | MEDLINE | ID: mdl-29752398

ABSTRACT

BACKGROUND: In patients with atrial fibrillation, left atrial appendage closure with the Watchman device prevents thromboembolism from the left atrial appendage; however, thrombus may form on the left atrial face of the device, and then potentially embolize. Herein, we studied the incidence, predictors, and clinical outcome of device-related thrombus (DRT) using a large series of clinical trial cohorts of patients undergoing Watchman implantation. METHODS: We studied the device arms of 4 prospective Food and Drug Administration trials: PROTECT-AF (Watchman Left Atrial Appendage System for Embolic Protection in Patients With Atrial Fibrillation) (n=463); PREVAIL (Evaluation of the Watchman LAA Closure Device in Patients With Atrial Fibrillation Versus Long Term Warfarin Therapy) (n=269); CAP (Continued Access to PROTECT AF registry) (n=566); and CAP2 (Continued Access to PREVAIL registry) (n=578). Surveillance transesophageal echocardiographs were performed at 45 days and 12 months in all patients, and also at 6 months in the randomized control trials. We assessed both the incidence of DRT during these transesophageal echocardiographs (and other unscheduled transesophageal echocardiographs), and clinical outcomes of postprocedure stroke or systemic embolism (SSE) and adjusted for CHA2DS2-VASC and HAS-BLED scores. RESULTS: Of 1739 patients who received an implant (7159 patient-years follow-up; CHA2DS2-VASc=4.0), DRT was seen in 65 patients (3.74%). The rates of SSE with and without DRT were 7.46 and 1.78 per 100 patient-years (adjusted rate ratio, 3.55; 95% confidence interval [CI], 2.18-5.79; P<0.001), and ischemic SSE rates were 6.28 and 1.65 per 100 patient-years (adjusted rate ratio, 3.22; 95% CI, 1.90-5.45, P<0.001). On multivariable modeling analysis, the predictors of DRT were as follows: history of transient ischemic attack or stroke (odds ratio [OR], 2.31; 95% CI, 1.26-4.25; P=0.007), permanent atrial fibrillation (OR, 2.24; 95% CI, 1.19-4.20; P=0.012); vascular disease (OR, 2.06; 95% CI, 1.08-3.91; P=0.028); left atrial appendage diameter (OR, 1.06 per mm increase; 95% CI, 1.01-1.12; P=0.019); left ventricular ejection fraction (OR, 0.96 per 1% increase; 95% CI, 0.94-0.99; P=0.009). DRT and SSE both occurred in 17 of 65 patients (26.2%). Of the 19 SSE events in these patients with DRT, 9 of 19 (47.4%) and 12 of 19 (63.2%) occurred within 1 and 6 months of DRT detection. Conversely, after left atrial appendage closure, most SSEs (123/142, 86.62%) occurred in patients without DRT. CONCLUSIONS: After left atrial appendage closure with Watchman, DRT (≈3.7%) is not frequent but, when present, is associated with a higher rate of stroke and systemic embolism.


Subject(s)
Atrial Appendage/physiopathology , Atrial Fibrillation/therapy , Atrial Function, Left , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Intracranial Embolism/epidemiology , Stroke/epidemiology , Thrombosis/epidemiology , Aged , Aged, 80 and over , Atrial Appendage/diagnostic imaging , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/physiopathology , Echocardiography, Transesophageal , Female , Humans , Incidence , Intracranial Embolism/diagnostic imaging , Male , Prosthesis Design , Randomized Controlled Trials as Topic , Registries , Retrospective Studies , Risk Assessment , Risk Factors , Stroke/diagnostic imaging , Thrombosis/diagnostic imaging , Time Factors , Treatment Outcome
7.
Am Heart J ; 211: 45-53, 2019 05.
Article in English | MEDLINE | ID: mdl-30831333

ABSTRACT

The Amulet IDE Trial is an ongoing, prospective, randomized, multi-national trial, designed to evaluate the safety and effectiveness of the AMPLATZER Amulet Left Atrial Appendage Occluder for stroke prevention in comparison to the WATCHMAN Left Atrial Appendage Closure Device in patients with non-valvular atrial fibrillation. METHODS: Non-valvular atrial fibrillation patients at high risk of stroke (CHADS2 score ≥2 or a CHA2DS2-VASc score of ≥3) who are suitable candidates for left atrial appendage occlusion (LAAO) will be fully informed and requested to participate in the trial. A total of 1878 patients at up to 150 sites worldwide will be randomized in a 1:1 ratio between the AMPLATZER Amulet device (investigational) and the Boston Scientific WATCHMAN device (control). Each patient will be followed for 5 years, with follow-up assessments at discharge, 45 days, 3, 6, 9, 12, 18, and 24 months and then annually. The trial has three primary endpoints: A composite of procedure-related complications, or all-cause death, or major bleeding through 12 months (safety); a composite of ischemic stroke or systemic embolism through 18 months (effectiveness); and effective device LAAO, defined as residual jet around the device ≤5 mm at the 45-day visit (mechanism of action). SUMMARY: The Amulet IDE Trial is the first randomized head-to-head LAAO device trial and will provide data for the AMPLATZER Amulet occluder in a population with a high risk of stroke and bleeding.


Subject(s)
Atrial Fibrillation/surgery , Cardiac Surgical Procedures/instrumentation , Septal Occluder Device , Anticoagulants/adverse effects , Anticoagulants/therapeutic use , Atrial Fibrillation/complications , Cardiac Catheterization , Cardiac Surgical Procedures/adverse effects , Cause of Death , Fibrinolytic Agents/adverse effects , Fibrinolytic Agents/therapeutic use , Hemorrhage/chemically induced , Hemorrhage/prevention & control , Humans , Postoperative Complications , Prospective Studies , Prosthesis Design , Risk Factors , Septal Occluder Device/adverse effects , Stroke/etiology , Stroke/prevention & control
8.
Am Heart J ; 202: 33-38, 2018 08.
Article in English | MEDLINE | ID: mdl-29803984

ABSTRACT

BACKGROUND: The Impella percutaneous ventricular assist device (PVAD) rapidly deploys mechanical circulatory support (MCS) in patients with acute myocardial infarction complicated by cardiogenic shock (AMICS). We present findings from a quality improvement (IQ) registry for US patients with AMICS who received Impella devices. METHODS AND RESULTS: From January 2009 to December 2016, 46,949 patients from 1010US hospitals were entered into the IQ registry; of these, 15,259 had AMICS. Limited de-identified patient information, product performance, and survival to explantation were recorded. Of those with AMICS, 51% survived to explantation of PVAD. There was a significant difference between survival at explantation with quintile volume at hospitals (range: 0-100%; 30% survival rate in lowest quintile vs. 76% in top quintile; P<.0001). Use of the Impella device as first-line treatment pre-PCI was associated with a 59% survival rate, compared with 52% when used as a salvage strategy (P<.001). The survival rate among those who received hemodynamic monitoring with pulmonary artery catheters was 63% as compared with 49% in those who did not (P<.0001). Overall institutional Impella volume was related to survival (56% survival at sites with >7/year vs. 51% at sites with ≤1; P<.001). CONCLUSIONS: In this early clinical experience with Impella support for AMICS, wide variation in outcomes existed across centers. Survival was higher when Impella was used as first support strategy, when invasive hemodynamic monitoring was used, and at centers with higher Impella implantation volume.


Subject(s)
Heart-Assist Devices , Hemodynamic Monitoring , Shock, Cardiogenic/mortality , Adult , Age Factors , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Myocardial Infarction/complications , Practice Patterns, Physicians' , Shock, Cardiogenic/etiology , Shock, Cardiogenic/therapy , Survival Rate , United States/epidemiology
9.
Am Heart J ; 199: 115-121, 2018 05.
Article in English | MEDLINE | ID: mdl-29754648

ABSTRACT

Management of patients requiring temporary, mechanical hemodynamic support during high- risk percutaneous coronary intervention (PCI) or in cardiogenic shock is rapidly evolving. With the availability of the Impella 2.5, CP, 5.0, LD, and RP percutaneous mechanical circulatory support devices, there is a need for continued surveillance of outcomes. Three factors underline the importance of a registry for these populations. First, large randomized trials of hemodynamic support, involving cardiogenic shock, are challenging to conduct. Second, there is increasing interest in the use of registries to provide "real-world" experience and to allow the flexibility to evaluate individual patient uses and outcomes. Third, current, large databases have not captured the specific impact of mechanical support treatment of cardiogenic shock. The predecessor to the catheter-based ventricular assist devices registry, known as USpella, began in 2009 with paper data acquisition but beginning in 2011 transferred to electronic data capture, enrolling 3,339 patients through 2016. Throughout, registry data have been used to assess the outcomes of Impella therapy, leading to 8 publications and 4 Food and Drug Administration premarket approvals covering multiple indications and Impella devices. Going forward, the registry will continue to assess not only in-hospital outcomes but long-term follow-up to 1 year. In addition, data management will be enhanced to assess quality and clinical experiences. The registry will also provide a mechanism for postmarketing surveillance. This manuscript reviews the ongoing catheter-based ventricular assist devices registry design, management, and contributions of the registry data. The upgraded registry will provide a more robust opportunity to assess acute and late outcomes of current and future device use worldwide. CONDENSED ABSTRACT: The current catheter-based ventricular assist devices registry is an international database documenting outcomes with temporary Impella hemodynamic support. The registry has supported 8 publications and 4 Food and Drug Administration premarket approvals since its inception in 2009. The current registry is more robust containing outcomes up to 1 year postprocedure.


Subject(s)
Heart Failure/surgery , Heart-Assist Devices , Hemodynamics/physiology , Percutaneous Coronary Intervention/methods , Registries , Shock, Cardiogenic/surgery , Equipment Design , Heart Failure/physiopathology , Humans , Prospective Studies , Risk Factors , Shock, Cardiogenic/physiopathology
10.
N Engl J Med ; 370(19): 1790-8, 2014 May 08.
Article in English | MEDLINE | ID: mdl-24678937

ABSTRACT

BACKGROUND: We compared transcatheter aortic-valve replacement (TAVR), using a self-expanding transcatheter aortic-valve bioprosthesis, with surgical aortic-valve replacement in patients with severe aortic stenosis and an increased risk of death during surgery. METHODS: We recruited patients with severe aortic stenosis who were at increased surgical risk as determined by the heart team at each study center. Risk assessment included the Society of Thoracic Surgeons Predictor Risk of Mortality estimate and consideration of other key risk factors. Eligible patients were randomly assigned in a 1:1 ratio to TAVR with the self-expanding transcatheter valve (TAVR group) or to surgical aortic-valve replacement (surgical group). The primary end point was the rate of death from any cause at 1 year, evaluated with the use of both noninferiority and superiority testing. RESULTS: A total of 795 patients underwent randomization at 45 centers in the United States. In the as-treated analysis, the rate of death from any cause at 1 year was significantly lower in the TAVR group than in the surgical group (14.2% vs. 19.1%), with an absolute reduction in risk of 4.9 percentage points (upper boundary of the 95% confidence interval, -0.4; P<0.001 for noninferiority; P = 0.04 for superiority). The results were similar in the intention-to-treat analysis. In a hierarchical testing procedure, TAVR was noninferior with respect to echocardiographic indexes of valve stenosis, functional status, and quality of life. Exploratory analyses suggested a reduction in the rate of major adverse cardiovascular and cerebrovascular events and no increase in the risk of stroke. CONCLUSIONS: In patients with severe aortic stenosis who are at increased surgical risk, TAVR with a self-expanding transcatheter aortic-valve bioprosthesis was associated with a significantly higher rate of survival at 1 year than surgical aortic-valve replacement. (Funded by Medtronic; U.S. CoreValve High Risk Study ClinicalTrials.gov number, NCT01240902.).


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Bioprosthesis , Cardiac Catheterization , Heart Valve Prosthesis , Aged , Aged, 80 and over , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/therapy , Cardiac Catheterization/adverse effects , Female , Humans , Kaplan-Meier Estimate , Male , Postoperative Complications , Prosthesis Design , Risk Factors , Survival Rate
11.
J Interv Cardiol ; 30(3): 256-263, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28419573

ABSTRACT

OBJECTIVES: To assess post-procedural outcomes when Impella 2.5 percutaneous left ventricular assist device (pLVAD) support is initiated either prior to or after percutaneous coronary intervention (PCI) on unprotected left main coronary artery (ULMCA) culprit lesion in the context of acute myocardial infarction cardiogenic shock (AMICS). BACKGROUND: Initiation of Impella 2.5 pLVAD prior to PCI is associated with significant survival benefit in the setting of AMICS. Outcomes of those presenting with a ULMCA culprit lesion in this setting have not been well characterized. METHODS: Thirty-six consecutive patients in the cVAD Registry supported with Impella 2.5 pLVAD for AMICS who underwent PCI on ULMCA culprit lesion were included in our multicenter study. RESULTS: The average age was 69.8 ± 14.2 years, 77.8% were male, 72.7% were in CS at admission, 44.4% sustained one or multiple cardiac arrests, and 30.6% had anoxic brain injury. Baseline characteristics were comparable between the Pre-PCI group (n = 20) and Post-PCI group (n = 16). Non-ST segment elevation myocardial infarction and greater coronary disease burden were significantly more frequent in the Pre-PCI group but they had significantly better survival to discharge (55.0% vs 18.8%, P = 0.041). Kaplan-Meier 30-day survival analysis showed very poor survival in Post-PCI group (48.1% vs 12.5%, Log-Rank P = 0.004). CONCLUSIONS: Initiation of Impella 2.5 pLVAD prior to as compared with after PCI of ULMCA for AMICS culprit lesion is associated with significant early survival. As previously described, patients supported after PCI appear to have very poor survival at 30 days.


Subject(s)
Assisted Circulation , Heart-Assist Devices , Myocardial Infarction , Percutaneous Coronary Intervention , Shock, Cardiogenic , Aged , Assisted Circulation/adverse effects , Assisted Circulation/instrumentation , Assisted Circulation/methods , Female , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Myocardial Infarction/complications , Myocardial Infarction/mortality , Myocardial Infarction/therapy , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/methods , Registries/statistics & numerical data , Shock, Cardiogenic/etiology , Shock, Cardiogenic/mortality , Treatment Outcome , United States/epidemiology
12.
Catheter Cardiovasc Interv ; 83(6): E183-92, 2014 May 01.
Article in English | MEDLINE | ID: mdl-24130115

ABSTRACT

UNLABELLED: This study evaluates the cost-effectiveness of percutaneous cardiac assist device (pVAD) therapy in the emergent setting compared with traditional surgical hemodynamic support alternatives. BACKGROUND: Previous research has demonstrated the cost-effectiveness of pVAD hemodynamic support for patients undergoing high-risk percutaneous coronary intervention. For patients in cardiogenic shock (CS), use of pVAD therapy has been shown to reduce length of stay (LOS). METHODS: National utilization and outcome data from the 2010-2011 MedPAR and state-sponsored all-payer databases were collected for patients with an acute myocardial infarction complicated by CS who were treated with either a pVAD (n = 883) or with traditional surgical hemodynamic support alternatives (ECMO and extracorporeal VAD) (n = 305). RESULTS: Discharge survival was greater with pVADs than with surgical alternatives (56% vs. 42%, P < 0.001) and was achieved with a strong trend toward reduced LOS (13.2 and 17.9 days, respectively, P = 0.055) and a significantly lower cost of the index admission ($90,929 and $144,257, respectively, P < 0.001). Cost-effectiveness analysis based on the national data demonstrated that pVAD achieved improved outcomes at lower cost. Data were also collected for similar patients who underwent protocol-guided pVAD therapy (using Impella 2.5) at PinnacleHealth, between 2009 and 2011 (n = 30). At this site, the survival rate increased to 60%, length of hospitalization was shortened to 6 days, and admission costs were lowered to $53,850 relative to the surgical alternatives strategy. CONCLUSIONS: For patients in CS requiring emergent hemodynamic support, pVAD therapy offers a less invasive alternative that can be deployed sooner, resulting in better outcomes, shorter LOS, lower costs and with no incremental cost, and a survival benefit when compared with traditional surgical hemodynamic support alternatives. PVAD therapy (and Impella 2.5 in particular) is emerging as a dominant strategy for this challenging patient population.


Subject(s)
Cardiac Catheterization/economics , Cardiology Service, Hospital/economics , Emergency Service, Hospital/economics , Heart-Assist Devices/economics , Hemodynamics , Myocardial Infarction/economics , Myocardial Infarction/therapy , Prosthesis Implantation/economics , Shock, Cardiogenic/economics , Shock, Cardiogenic/therapy , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Cardiac Catheterization/mortality , Cost-Benefit Analysis , Hospital Costs , Humans , Length of Stay/economics , Models, Economic , Myocardial Infarction/complications , Myocardial Infarction/diagnosis , Myocardial Infarction/mortality , Myocardial Infarction/physiopathology , Patient Discharge/economics , Pennsylvania , Prosthesis Design , Prosthesis Implantation/adverse effects , Prosthesis Implantation/instrumentation , Prosthesis Implantation/methods , Prosthesis Implantation/mortality , Quality-Adjusted Life Years , Retrospective Studies , Shock, Cardiogenic/diagnosis , Shock, Cardiogenic/etiology , Shock, Cardiogenic/mortality , Shock, Cardiogenic/physiopathology , Time Factors , Treatment Outcome
13.
J Interv Cardiol ; 27(1): 1-11, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24329756

ABSTRACT

OBJECTIVES: To evaluate the periprocedural characteristics and outcomes of patients supported with Impella 2.5 prior to percutaneous coronary intervention (pre-PCI) versus those who received it after PCI (post-PCI) in the setting of cardiogenic shock (CS) complicating an acute myocardial infarction (AMI). BACKGROUND: Early mechanical circulatory support may improve outcome in the setting of CS complicating an AMI. However, the optimal timing to initiate hemodynamic support has not been well characterized. METHODS: Data from 154 consecutive patients who underwent PCI and Impella 2.5 support from 38 US hospitals participating in the USpella Registry were included in our study. The primary end-point was survival to discharge. Secondary end-points included assessment of patients' hemodynamics and in-hospital complications. A multivariate regression model was used to identify independent predictors for mortality. RESULTS: Both groups were comparable except for diabetes (P = 0.02), peripheral vascular disease (P = 0.008), chronic obstructive pulmonary disease (P = 0.05), and prior stroke (P = 0.04), all of which were more prevalent in the pre-PCI group. Patients in the pre-PCI group had more lesions (P = 0.006) and vessels (P = 0.01) treated. These patients had also significantly better survival to discharge compared to patients in the post-PCI group (65.1% vs.40.7%, P = 0.003). Survival remained favorable for the pre-PCI group after adjusting for potential confounding variables. Initiation of support prior to PCI with Impella 2.5 was an independent predictor of in-hospital survival (Odds ratio 0.37, 95% confidence interval: 0.17-0.79, P = 0.01) in multivariate analysis. The incidence of in-hospital complications included in the secondary end-point was similar between the 2 groups. CONCLUSIONS: The results of our study suggest that early initiation of hemodynamic support prior to PCI with Impella 2.5 is associated with more complete revascularization and improved survival in the setting of refractory CS complicating an AMI.


Subject(s)
Myocardial Infarction/surgery , Percutaneous Coronary Intervention/instrumentation , Shock, Cardiogenic/complications , Female , Heart-Assist Devices , Humans , Male , Middle Aged , Percutaneous Coronary Intervention/methods , Percutaneous Coronary Intervention/mortality , Registries , Treatment Outcome
14.
Circulation ; 126(14): 1717-27, 2012 Oct 02.
Article in English | MEDLINE | ID: mdl-22935569

ABSTRACT

BACKGROUND: Although coronary artery bypass grafting is generally preferred in symptomatic patients with severe, complex multivessel, or left main disease, some patients present with clinical features that make coronary artery bypass grafting clinically unattractive. Percutaneous coronary intervention with hemodynamic support may be feasible for these patients. Currently, there is no systematic comparative evaluation of hemodynamic support devices for this indication. METHODS AND RESULTS: We randomly assigned 452 symptomatic patients with complex 3-vessel disease or unprotected left main coronary artery disease and severely depressed left ventricular function to intra-aortic balloon pump (IABP) (n=226) or Impella 2.5 (n=226) support during nonemergent high-risk percutaneous coronary intervention. The primary end point was the 30-day incidence of major adverse events. A 90-day follow-up was required, as well, by protocol. Impella 2.5 provided superior hemodynamic support in comparison with IABP, with maximal decrease in cardiac power output from baseline of -0.04±0.24 W in comparison with -0.14±0.27 W for IABP (P=0.001). The primary end point (30-day major adverse events) was not statistically different between groups: 35.1% for Impella 2.5 versus 40.1% for IABP, P=0.227 in the intent-to-treat population and 34.3% versus 42.2%, P=0.092 in the per protocol population. At 90 days, a strong trend toward decreased major adverse events was observed in Impella 2.5-supported patients in comparison with IABP: 40.6% versus 49.3%, P=0.066 in the intent-to-treat population and 40.0% versus 51.0%, P=0.023 in the per protocol population, respectively. CONCLUSIONS: The 30-day incidence of major adverse events was not different for patients with IABP or Impella 2.5 hemodynamic support. However, trends for improved outcomes were observed for Impella 2.5-supported patients at 90 days. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00562016.


Subject(s)
Hemodynamics , Intra-Aortic Balloon Pumping/adverse effects , Percutaneous Coronary Intervention/adverse effects , Postoperative Complications/epidemiology , Aged , Cohort Studies , Female , Follow-Up Studies , Hemodynamics/physiology , Humans , Male , Middle Aged , Postoperative Complications/etiology , Postoperative Complications/mortality , Prospective Studies , Risk Factors , Survival Rate/trends
15.
Eur Heart J ; 33(3): 372-83, 2012 Feb.
Article in English | MEDLINE | ID: mdl-22019821

ABSTRACT

AIMS: To test the hypothesis that near-infrared spectroscopy (NIRS) combined with intravascular ultrasound (IVUS) would provide novel information of human coronary plaque characterization. METHODS AND RESULTS: Greyscale-IVUS, virtual histology (VH)-IVUS, and NIRS were compared in 131 native lesions (66 vessels) that were interrogated during catheterization by all three modalities. Greyscale-IVUS detected attenuated and echolucent plaques correlated with NIRS-detected lipid-rich areas. Attenuated plaques contained the highest NIRS probability of lipid core, followed by echolucent plaques. By VH-IVUS, 93.5% of attenuated plaques contained confluent necrotic core (NC) and were classified as VH-derived fibroatheromas (FAs). Although 75.0% of echolucent plaques were classified as VH-FAs, VH-NC was seen surrounding an echolucent zone, but not within any echolucent zone; and echolucent zones themselves contained fibrofatty and/or fibrous tissue. All calcified plaques with arc >90° contained >10% VH-NC (range 16.0-41.2%) and were classified as calcified VH-FAs, but only 58.5% contained NIRS-detected lipid core. A positive relationship between VH-derived %NC and NIRS-derived lipid core burden index was found in non-calcified plaques, but not in calcified plaques. CONCLUSION: Combining NIRS with IVUS contributes to the understanding of plaque characterization in vivo. Further studies are warranted to determine whether combining NIRS and IVUS will contribute to the assessment of high-risk plaques to predict outcomes in patients with coronary artery disease.


Subject(s)
Coronary Artery Disease/diagnosis , Plaque, Atherosclerotic/diagnosis , Spectroscopy, Near-Infrared/methods , Ultrasonography, Interventional/methods , Aged , Coronary Artery Disease/diagnostic imaging , Female , Humans , Image Processing, Computer-Assisted/methods , Male , Middle Aged , Plaque, Atherosclerotic/diagnostic imaging
16.
Am J Cardiol ; 209: 181-183, 2023 12 15.
Article in English | MEDLINE | ID: mdl-37863115

ABSTRACT

Suture-mediated closure device and Figure-of-Eight suture are commonly used to achieve hemostasis after use of large bore venous access. Although both methods of closure are commonly used in clinical practice, a head-to-head comparison in a controlled setting has not been performed. Patients presenting to a single center for elective left atrial appendage occlusion or transcatheter edge-to-edge mitral valve repair were randomized to large bore venous closure using the Perclose ProGlide suture-based closure or a Figure-of-Eight suture closure. The patients were followed for 1 month after the procedure. Primary outcome, a composite of access site large ecchymosis, hematoma, infection, pain, need for unscheduled venous ultrasound and need for transfusion, was compared between the 2 arms. A total of 40 patients were randomized in a 1:1 fashion to the 2 venous closure strategies. Baseline characteristics were similar between the 2 groups. Perclose ProGlide arm required use of more devices for hemostasis (1.5 ± 0.5 vs 1 ± 0 respectively, p <0.0001), and there was a significant difference in the cost of closure device ($367.00 ± 122.00 vs $1.00 ± 0 respectively, p <0.001). At 1 month post-procedure, the primary outcome occurred in 4 patients (20%) in the Perclose arm and 7 (35%) patients in the Figure-of-Eight arm, a difference that was not statistically significant (p = 0.48). Time to hemostasis between Figure-of-Eight and Perclose arms did not reach statistical significance (2.5 ± 2.1 vs 3.7 ± 2.3, p = 0.09). In conclusion, both Perclose ProGlide suture-based device and Figure-of-Eight closure are equally feasible and safe for patients who underwent large bore venous access. Figure-of-Eight-based closure is more cost effective.


Subject(s)
Hemostasis, Surgical , Vascular Closure Devices , Humans , Femoral Artery/surgery , Hemostasis , Hemostasis, Surgical/methods , Hemostatic Techniques , Suture Techniques , Sutures , Treatment Outcome , Vascular Surgical Procedures
17.
Am J Cardiol ; 202: 144-150, 2023 09 01.
Article in English | MEDLINE | ID: mdl-37437355

ABSTRACT

Atrial fibrillation is a major risk factor for stroke. Left atrial appendage closure (LAAC) has emerged as an alternative to anticoagulation for patients with high risk of bleeding. Diabetes mellitus (DM) is associated with adverse events after cardiac procedures. We sought to compare procedural and hospital outcomes in patients who underwent LAAC with and without DM. The Nationwide Inpatient Database was queried for patients with atrial fibrillation who underwent LAAC between January 1, 2016, and December 31, 2019. The primary outcome was all adverse events that included in-hospital death, acute myocardial infarction, cardiac arrest, stroke, pericardial effusion, pericardial tamponade, pericardiocentesis, pericardial window, and postprocedural hemorrhage requiring blood transfusion. Analysis included 62,220 patients who underwent LAAC from 2016 to 2019; 34.9% of patients had DM. There was a slight increase in the percentage of patients who underwent LAAC who had DM during the study period, from 29.92% to 34.93%. In unadjusted and adjusted analysis, there was no significant difference in all adverse events between patients with and without DM who underwent LAAC (9.18% vs 8.77%, respectively, adjusted p = 0.63), and no difference in length of stay. Patients with DM have higher risk of acute kidney injury (3.75 vs 1.96%, p <0.001). This nationwide retrospective study demonstrates that DM is not associated with an increase in adverse event rates in patients who underwent LAAC.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Diabetes Mellitus , Stroke , Humans , Atrial Fibrillation/complications , Atrial Fibrillation/epidemiology , Atrial Fibrillation/surgery , Atrial Appendage/surgery , Retrospective Studies , Hospital Mortality , Stroke/epidemiology , Stroke/etiology , Stroke/prevention & control , Treatment Outcome
18.
JACC Cardiovasc Interv ; 16(4): 415-425, 2023 02 27.
Article in English | MEDLINE | ID: mdl-36858660

ABSTRACT

BACKGROUND: Transcatheter aortic valve replacement (TAVR)-related coronary artery obstruction prediction remains unsatisfactory despite high mortality and novel preventive therapies. OBJECTIVES: This study sought to develop a predictive model for TAVR-related coronary obstruction in native aortic stenosis. METHODS: Preprocedure computed tomography and fluoroscopy images of patients in whom TAVR caused coronary artery obstruction were collected. Central laboratories made measurements, which were compared with unobstructed patients from a single-center database. A multivariate model was developed and validated against a 1:1 propensity-matched subselection of the unobstructed cohort. RESULTS: Sixty patients with angiographically confirmed coronary obstruction and 1,381 without obstruction were included. In-hospital death was higher in the obstruction cohort (26.7% vs 0.7%; P < 0.001). Annular area and perimeter, coronary height, sinus width, and sinotubular junction height and width were all significantly smaller in the obstructed cohort. Obstruction was most common on the left side (78.3%) and at the level of the coronary artery ostium (92.1%). Coronary artery height and sinus width, but not annulus area, were significant risk factors for obstruction by logistic regression but performed poorly in predicting obstruction. The new multivariate model (coronary obstruction IF cusp height > coronary height, AND virtual valve-to-coronary distance ≤4 mm OR culprit leaflet calcium volume >600 mm3) performed well, with an area under the curve of 0.93 (sensitivity = 0.93, specificity = 0.84) for the left coronary artery and 0.94 (sensitivity = 0.92, specificity = 0.96) for the right. CONCLUSIONS: A novel computed tomography-based multivariate prediction model that can be implemented routinely in real-world practice predicted coronary artery obstruction from TAVR in native aortic stenosis.


Subject(s)
Aortic Valve Stenosis , Coronary Occlusion , Transcatheter Aortic Valve Replacement , Humans , Hospital Mortality , Treatment Outcome , Heart
19.
Catheter Cardiovasc Interv ; 80(5): 717-25, 2012 Nov 01.
Article in English | MEDLINE | ID: mdl-22105829

ABSTRACT

OBJECTIVES: We report on the real-world, multicenter experience of the Impella 2.5 circulatory support system during high-risk PCI, a subset of the larger USpella Registry. BACKGROUND: Standard of care for most patients with compromised ventricular function with multivessel or high-risk coronary lesions has been coronary artery bypass grafting. In poor operative candidates, high-risk PCI is increasingly considered, despite an increased risk for periprocedural hemodynamic compromise. METHODS: 175 consecutive patients who underwent high-risk PCI with prophylactic support of the Impella 2.5 were evaluated. The primary safety endpoint was the incidence of major adverse cardiac events (MACE) at 30 days. Secondary endpoints included safety and efficacy related to the device and patient outcomes, including survival at 12 months. RESULTS: Overall angiographic revascularization was successful in 99% of patients and in 90% of those with multivessel revascularization, resulting in a reduction of the mean SYNTAX score post-PCI from 36 ± 15 to 18 ± 15 (P < 0.0001) and an improvement of the ejection fraction (from 31 ± 15% to 36 ± 14%, P < 0.0001). In 51% of patients, the functional status improved by one or more NYHA class (P < 0.001). At 30-day follow-up, the rate of MACE was 8%, and survival was 96%, 91%, and 88% at 30 days, 6 months, and 12 months, respectively. CONCLUSIONS: The use of Impella 2.5 in high-risk PCI appeared feasible and safe in the real-world setting. The utilization of the Impella 2.5 was successful, resulting in favorable short- and midterm angiographic, procedural and clinical outcomes.


Subject(s)
Coronary Artery Disease/therapy , Heart-Assist Devices , Percutaneous Coronary Intervention , Ventricular Dysfunction, Left/therapy , Adult , Aged , Aged, 80 and over , Chi-Square Distribution , Coronary Angiography , Coronary Artery Disease/complications , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Coronary Artery Disease/physiopathology , Female , Heart-Assist Devices/adverse effects , Hemodynamics , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Prosthesis Design , Recovery of Function , Registries , Risk Factors , Stroke Volume , Time Factors , Treatment Outcome , United States , Ventricular Dysfunction, Left/complications , Ventricular Dysfunction, Left/mortality , Ventricular Dysfunction, Left/physiopathology , Ventricular Function, Left
20.
Cardiovasc Revasc Med ; 36: 132-135, 2022 03.
Article in English | MEDLINE | ID: mdl-33958304

ABSTRACT

BACKGROUND: The modes of failure of coronary polymer-jacketed guidewires have received limited study. METHODS: We queried the Manufacturer and User Facility Device Experience (MAUDE) database between January 2011 and December 2020 for reports on coronary polymer-jacketed guidewires and retrieved 254 reports. RESULTS: The most common failure mode was failure of the guidewire to cross (36.2%), followed by guidewire fracture (35%), peeling of the polymer jacket (13.8%), failure to retrieve the guidewire (13.8%), and guidewire unraveling (4.7%). Guidewire fracture was more common with soft (37.3%) compared with stiff (23.8%) guidewires. Failure of retrieval was only reported with soft guidewires (9%). Coronary perforation and dissection occurred in 19.7% and 7.9% of the reports, with more reports with stiff as compared with soft guidewires (45.2% vs. 14.6% for perforation and 21.4% vs. 5.3% for dissection). CONCLUSIONS: The most common failure modes of polymer-jacketed guidewires during percutaneous coronary intervention are failure to cross the lesion, guidewire fracture, and peeling of the polymer jacket. Coronary perforations were more common with stiff whereas wire fracture was more common with soft polymer-jacketed guidewires.


Subject(s)
Percutaneous Coronary Intervention , Polymers , Coronary Angiography , Databases, Factual , Humans , Percutaneous Coronary Intervention/adverse effects , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL