Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 63
Filter
1.
Phys Rev Lett ; 125(12): 120504, 2020 Sep 18.
Article in English | MEDLINE | ID: mdl-33016760

ABSTRACT

Quantum algorithms offer a dramatic speedup for computational problems in material science and chemistry. However, any near-term realizations of these algorithms will need to be optimized to fit within the finite resources offered by existing noisy hardware. Here, taking advantage of the adjustable coupling of gmon qubits, we demonstrate a continuous two-qubit gate set that can provide a threefold reduction in circuit depth as compared to a standard decomposition. We implement two gate families: an imaginary swap-like (iSWAP-like) gate to attain an arbitrary swap angle, θ, and a controlled-phase gate that generates an arbitrary conditional phase, ϕ. Using one of each of these gates, we can perform an arbitrary two-qubit gate within the excitation-preserving subspace allowing for a complete implementation of the so-called Fermionic simulation (fSim) gate set. We benchmark the fidelity of the iSWAP-like and controlled-phase gate families as well as 525 other fSim gates spread evenly across the entire fSim(θ,ϕ) parameter space, achieving a purity-limited average two-qubit Pauli error of 3.8×10^{-3} per fSim gate.

2.
Phys Rev Lett ; 123(21): 210501, 2019 Nov 22.
Article in English | MEDLINE | ID: mdl-31809160

ABSTRACT

We demonstrate diabatic two-qubit gates with Pauli error rates down to 4.3(2)×10^{-3} in as fast as 18 ns using frequency-tunable superconducting qubits. This is achieved by synchronizing the entangling parameters with minima in the leakage channel. The synchronization shows a landscape in gate parameter space that agrees with model predictions and facilitates robust tune-up. We test both iswap-like and cphase gates with cross-entropy benchmarking. The presented approach can be extended to multibody operations as well.

3.
Med Phys ; 39(3): 1618-31, 2012 Mar.
Article in English | MEDLINE | ID: mdl-22380394

ABSTRACT

PURPOSE: To investigate the behavior of plane-parallel ion chambers in high-energy photon beams through measurements and Monte Carlo simulations. METHODS: Ten plane-parallel ion chamber types were obtained from the major ion chamber manufacturers. Absorbed dose-to-water calibration coefficients are measured for these chambers and k(Q) factors are determined. In the process, the behaviors of the chambers are characterized through measurements of leakage currents, chamber settling in cobalt-60, polarity and ion recombination behavior, and long-term stability. Monte Carlo calculations of the absorbed dose to the air in the ion chamber and absorbed dose to water are obtained to calculate k(Q) factors. Systematic uncertainties in Monte Carlo calculated k(Q) factors are investigated by varying material properties and chamber dimensions. RESULTS: Chamber behavior was variable in MV photon beams, especially with regard to chamber leakage and ion recombination. The plane-parallel chambers did not perform as well as cylindrical chambers. Significant differences up to 1.5% were observed in calibration coefficients after a period of eight months although k(Q) factors were consistent on average within 0.17%. Chamber-to-chamber variations in k(Q) factors for chambers of the same type were at the 0.2% level. Systematic uncertainties in Monte Carlo calculated k(Q) factors ranged between 0.34% and 0.50% depending on the chamber type. Average percent differences between measured and calculated k(Q) factors were - 0.02%, 0.18%, and - 0.16% for 6, 10, and 25 MV beams, respectively. CONCLUSIONS: Excellent agreement is observed on average at the 0.2% level between measured and Monte Carlo calculated k(Q) factors. Measurements indicate that the behavior of these chambers is not adequate for their use for reference dosimetry of high-energy photon beams without a more extensive QA program than currently used for cylindrical reference-class ion chambers.


Subject(s)
Photons , Radiometry/instrumentation , Monte Carlo Method , Time Factors , Uncertainty
4.
Med Phys ; 39(10): 5990-6003, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23039637

ABSTRACT

PURPOSE: There are three goals for this study: (a) to perform detailed megavoltage transmission measurements in order to identify the factors that affect the measurement accuracy, (b) to use the measured data as a benchmark for the EGSnrc system in order to identify the computational limiting factors, and (c) to provide data for others to benchmark Monte Carlo codes. METHODS: Transmission measurements are performed at the National Research Council Canada on a research linac whose incident electron parameters are independently known. Automated transmission measurements are made on-axis, down to a transmission value of ∼1.7%, for eight beams between 10 MV (the lowest stable MV beam on the linac) and 30 MV, using fully stopping Be, Al, and Pb bremsstrahlung targets and no fattening filters. To diversify energy differentiation, data are acquired for each beam using low-Z and high-Z attenuators (C and Pb) and Farmer chambers with low-Z and high-Z buildup caps. Experimental corrections are applied for beam drifts (2%), polarity (2.5% typical maximum, 6% extreme), ion recombination (0.2%), leakage (0.3%), and room scatter (0.8%)-the values in parentheses are the largest corrections applied. The experimental setup and the detectors are modeled using EGSnrc, with the newly added photonuclear attenuation included (up to a 5.6% effect). A detailed sensitivity analysis is carried out for the measured and calculated transmission data. RESULTS: The developed experimental protocol allows for transmission measurements with 0.4% uncertainty on the smallest signals. Suggestions for accurate transmission measurements are provided. Measurements and EGSnrc calculations agree typically within 0.2% for the sensitivity of the transmission values to the detector details, to the bremsstrahlung target material, and to the incident electron energy. Direct comparison of the measured and calculated transmission data shows agreement better than 2% for C (3.4% for the 10 MV beam) and typically better than 1% for Pb. The differences can be explained by acceptable photon cross section changes of ≤0.4%. CONCLUSIONS: Accurate transmission measurements require accounting for a number of influence quantities which, if ignored, can collectively introduce errors larger than 10%. Accurate transmission calculations require the use of the most accurate data and physics options available in EGSnrc, particularly the more accurate bremsstrahlung angular sampling option and the newly added modeling of photonuclear attenuation. Comparison between measurements and calculations implies that EGSnrc is accurate within 0.2% for relative ion chamber response calculations. Photon cross section uncertainties are the ultimate limiting factor for the accuracy of the calculated transmission data (Monte Carlo or analytical).


Subject(s)
Benchmarking/methods , Radiometry/instrumentation , Monte Carlo Method , Photons , Scattering, Radiation
5.
Med Phys ; 39(11): 6585-96, 2012 Nov.
Article in English | MEDLINE | ID: mdl-23127053

ABSTRACT

PURPOSE: In a recent computational study, an improved physics-based approach was proposed for unfolding linac photon spectra and incident electron energies from transmission data. In this approach, energy differentiation is improved by simultaneously using transmission data for multiple attenuators and detectors, and the unfolding robustness is improved by using a four-parameter functional form to describe the photon spectrum. The purpose of the current study is to validate this approach experimentally, and to demonstrate its application on a typical clinical linac. METHODS: The validation makes use of the recent transmission measurements performed on the Vickers research linac of National Research Council Canada. For this linac, the photon spectra were previously measured using a NaI detector, and the incident electron parameters are independently known. The transmission data are for eight beams in the range 10-30 MV using thick Be, Al and Pb bremsstrahlung targets. To demonstrate the approach on a typical clinical linac, new measurements are performed on an Elekta Precise linac for 6, 10 and 25 MV beams. The different experimental setups are modeled using EGSnrc, with the newly added photonuclear attenuation included. RESULTS: For the validation on the research linac, the 95% confidence bounds of the unfolded spectra fall within the noise of the NaI data. The unfolded spectra agree with the EGSnrc spectra (calculated using independently known electron parameters) with RMS energy fluence deviations of 4.5%. The accuracy of unfolding the incident electron energy is shown to be ∼3%. A transmission cutoff of only 10% is suitable for accurate unfolding, provided that the other components of the proposed approach are implemented. For the demonstration on a clinical linac, the unfolded incident electron energies and their 68% confidence bounds for the 6, 10 and 25 MV beams are 6.1 ± 0.1, 9.3 ± 0.1, and 19.3 ± 0.2 MeV, respectively. The unfolded spectra for the clinical linac agree with the EGSnrc spectra (calculated using the unfolded electron energies) with RMS energy fluence deviations of 3.7%. The corresponding measured and EGSnrc-calculated transmission data agree within 1.5%, where the typical transmission measurement uncertainty on the clinical linac is 0.4% (not including the uncertainties on the incident electron parameters). CONCLUSIONS: The approach proposed in an earlier study for unfolding photon spectra and incident electron energies from transmission data is accurate and practical for clinical use.


Subject(s)
Electrons , Photons , Statistics as Topic/methods , Humans , Monte Carlo Method , Reproducibility of Results , Spectrum Analysis
6.
Med Phys ; 38(8): 4600-9, 2011 Aug.
Article in English | MEDLINE | ID: mdl-21928633

ABSTRACT

PURPOSE: The journal Medical Physics recently published two papers that determine beam quality conversion factors, k(Q), for large sets of ion chambers. In the first paper [McEwen Med. Phys. 37, 2179-2193 (2010)], k(Q) was determined experimentally, while the second paper [Muir and Rogers Med. Phys. 37, 5939-5950 (2010)] provides k(Q) factors calculated using Monte Carlo simulations. This work investigates a variety of additional consistency checks to verify the accuracy of the k(Q) factors determined in each publication and a comparison of the two data sets. Uncertainty introduced in calculated k(Q) factors by possible variation of W/e with beam energy is investigated further. METHODS: The validity of the experimental set of k(Q) factors relies on the accuracy of the NE2571 reference chamber measurements to which k(Q) factors for all other ion chambers are correlated. The stability of NE2571 absorbed dose to water calibration coefficients is determined and comparison to other experimental k(Q) factors is analyzed. Reliability of Monte Carlo calculated k(Q) factors is assessed through comparison to other publications that provide Monte Carlo calculations of k(Q) as well as an analysis of the sleeve effect, the effect of cavity length and self-consistencies between graphite-walled Farmer-chambers. Comparison between the two data sets is given in terms of the percent difference between the k(Q) factors presented in both publications. RESULTS: Monitoring of the absorbed dose calibration coefficients for the NE2571 chambers over a period of more than 15 yrs exhibit consistency at a level better than 0.1%. Agreement of the NE2571 k(Q) factors with a quadratic fit to all other experimental data from standards labs for the same chamber is observed within 0.3%. Monte Carlo calculated k(Q) factors are in good agreement with most other Monte Carlo calculated k(Q) factors. Expected results are observed for the sleeve effect and the effect of cavity length on k(Q). The mean percent differences between experimental and Monte Carlo calculated k(Q) factors are -0.08, -0.07, and -0.23% for the Elekta 6, 10, and 25 MV nominal beam energies, respectively. An upper limit on the variation of W/e in photon beams from cobalt-60 to 25 MV is determined as 0.4% with 95% confidence. The combined uncertainty on Monte Carlo calculated k(Q) factors is reassessed and amounts to between 0.40 and 0.49% depending on the wall material of the chamber. CONCLUSIONS: Excellent agreement (mean percent difference of only 0.13% for the entire data set) between experimental and calculated k(Q) factors is observed. For some chambers, k(Q) is measured for only one chamber of each type--the level of agreement observed in this study would suggest that for those chambers the measured k(Q) values are generally representative of the chamber type.


Subject(s)
Radiometry/statistics & numerical data , Biophysical Phenomena , Calibration , Humans , Monte Carlo Method , Radiation Dosage , Radiometry/instrumentation , Radiometry/standards , Radiotherapy Planning, Computer-Assisted/instrumentation , Radiotherapy Planning, Computer-Assisted/standards , Radiotherapy Planning, Computer-Assisted/statistics & numerical data , Reproducibility of Results
7.
Eur J Appl Physiol ; 111(12): 3007-16, 2011 Dec.
Article in English | MEDLINE | ID: mdl-21451937

ABSTRACT

The optimal volume of resistance exercise to prescribe for trained individuals is unclear. The purpose of this study was to randomly assign resistance trained individuals to 6-weeks of squat exercise, prescribed at 80% of a 1 repetition-maximum (1-RM), using either one, four, or eight sets of repetitions to failure performed twice per week. Participants then performed the same peaking program for 4-weeks. Squat 1-RM, quadriceps muscle activation, and contractile rate of force development (RFD) were measured before, during, and after the training program. 32 resistance-trained male participants completed the 10-week program. Squat 1-RM was significantly increased for all groups after 6 and 10-weeks of training (P < 0.05). The 8-set group was significantly stronger than the 1-set group after 3-weeks of training (7.9% difference, P < 0.05), and remained stronger after 6 and 10-weeks of training (P < 0.05). Peak muscle activation did not change during the study. Early (30, 50 ms) and peak RFD was significantly decreased for all groups after 6 and 10-weeks of training (P < 0.05). Peak isometric force output did not change for any group. The results of this study support resistance exercise prescription in excess of 4-sets (i.e. 8-sets) for faster and greater strength gains as compared to 1-set training. Common neuromuscular changes are attributed to high intensity squats (80% 1-RM) combined with a repetition to failure prescription. This prescription may not be useful for sports application owing to decreased early and peak RFD. Individual responsiveness to 1-set of training should be evaluated in the first 3-weeks of training.


Subject(s)
Adaptation, Physiological/physiology , Exercise/physiology , Muscle Contraction/physiology , Muscle Strength/physiology , Muscle, Skeletal/physiology , Physical Endurance/physiology , Resistance Training/methods , Adult , Body Composition/physiology , Humans , Male , Sports/physiology
8.
Nat Commun ; 12(1): 1761, 2021 Mar 19.
Article in English | MEDLINE | ID: mdl-33741936

ABSTRACT

Quantum computing can become scalable through error correction, but logical error rates only decrease with system size when physical errors are sufficiently uncorrelated. During computation, unused high energy levels of the qubits can become excited, creating leakage states that are long-lived and mobile. Particularly for superconducting transmon qubits, this leakage opens a path to errors that are correlated in space and time. Here, we report a reset protocol that returns a qubit to the ground state from all relevant higher level states. We test its performance with the bit-flip stabilizer code, a simplified version of the surface code for quantum error correction. We investigate the accumulation and dynamics of leakage during error correction. Using this protocol, we find lower rates of logical errors and an improved scaling and stability of error suppression with increasing qubit number. This demonstration provides a key step on the path towards scalable quantum computing.

9.
Phys Med Biol ; 65(9): 095011, 2020 05 07.
Article in English | MEDLINE | ID: mdl-32182598

ABSTRACT

The IAEA is currently coordinating a multi-year project to update the TRS-398 Code of Practice for the dosimetry of external beam radiotherapy based on standards of absorbed dose to water. One major aspect of the project is the determination of new beam quality correction factors, k Q , for megavoltage photon beams consistent with developments in radiotherapy dosimetry and technology since the publication of TRS-398 in 2000. Specifically, all values must be based on, or consistent with, the key data of ICRU Report 90. Data sets obtained from Monte Carlo (MC) calculations by advanced users and measurements at primary standards laboratories have been compiled for 23 cylindrical ionization chamber types, consisting of 725 MC-calculated and 179 experimental data points. These have been used to derive consensus k Q values as a function of the beam quality index TPR20,10 with a combined standard uncertainty of 0.6%. Mean values of MC-derived chamber-specific [Formula: see text] factors for cylindrical and plane-parallel chamber types in 60Co beams have also been obtained with an estimated uncertainty of 0.4%.


Subject(s)
Cobalt Radioisotopes/analysis , Monte Carlo Method , Photons/therapeutic use , Radiometry/methods , Radiometry/standards , Consensus , Humans , Radiotherapy Planning, Computer-Assisted , Relative Biological Effectiveness , Uncertainty
10.
Physiol Meas ; 30(9): 869-83, 2009 Sep.
Article in English | MEDLINE | ID: mdl-19636087

ABSTRACT

Despite its success as a clinical monitoring tool, pulse oximetry may be improved with respect to the need for empirical calibration and the reports of biases in readings associated with peripheral vasoconstriction and haemoglobin concentration. To effect this improvement, this work aims to improve the understanding of the photoplethysmography signal-as used by pulse oximeters-and investigates the effect of vessel calibre and haemoglobin concentration on pulse oximetry. The digital temperature and the transmission of a wide spectrum of light through the fingers of 57 people with known haemoglobin concentrations were measured and simulations of the transmission of that spectrum of light through finger models were performed. Ratios of pulsatile attenuations of light as used in pulse oximetry were dependent upon peripheral temperature and on blood haemoglobin concentration. In addition, both the simulation and in vivo results showed that the pulsatile attenuation of light through fingers was approximately proportional to the absorption coefficients of blood, only when the absorption coefficients were small. These findings were explained in terms of discrete blood vessels acting as barriers to light transmission through tissue. Due to the influence of discrete blood vessels on light transmission, pulse oximeter outputs tend to be dependent upon haemoglobin concentration and on the calibre of pulsing blood vessels-which are affected by vasoconstriction/vasodilation. The effects of discrete blood vessels may account for part of the difference between the Beer-Lambert pulse oximetry model and empirical calibration.


Subject(s)
Blood Vessels/anatomy & histology , Blood Vessels/physiology , Hemoglobins/physiology , Oximetry , Aged , Body Temperature/physiology , Calibration , Data Interpretation, Statistical , Female , Fingers/blood supply , Humans , Hydrogen-Ion Concentration , Light , Male , Middle Aged , Monte Carlo Method , Photoplethysmography , Regional Blood Flow/physiology , Scattering, Radiation , Vasoconstriction/physiology , Vasodilation/physiology
11.
Aust Vet J ; 97(6): 197-201, 2019 Jun.
Article in English | MEDLINE | ID: mdl-31136692

ABSTRACT

CASE REPORT: We describe the clinical signs and management of a case of anaphylaxis in a dog after intravenous administration of alphaxalone (Alfaxan®, Jurox, NSW, Aust), which has not been previously published. A female spayed cattle dog undergoing routine imaging for forelimb lameness was induced with Alfaxan after receiving sedation with acepromazine and methadone 70 min prior. Immediately after intravenous administration of Alfaxan, the dog exhibited vomiting and diarrhoea associated with acute hypotension. Gallbladder wall oedema was visualised consistent with anaphylaxis. The dog responded to rapid volume expansion. Adrenaline was not required. The dog made a full recovery within 6 h of the reaction and was re-anaesthetised 3 days later without incident, using propofol as the induction agent. CONCLUSION: To our knowledge, this is the first published case of anaphylaxis associated with intravenous Alfaxan in the dog. The APVMA reporting of reactions in small animals from 2003 to 2013 of Alfaxan is consistent with this case report's finding involving the respiratory, circulatory and gastrointestinal systems.


Subject(s)
Anaphylaxis/veterinary , Anesthetics/adverse effects , Dog Diseases/chemically induced , Pregnanediones/adverse effects , Anaphylaxis/chemically induced , Anesthetics/therapeutic use , Animals , Dogs , Female , Pregnanediones/therapeutic use
12.
Equine Vet J ; 51(4): 510-516, 2019 Jul.
Article in English | MEDLINE | ID: mdl-30451308

ABSTRACT

BACKGROUND: There is no information directly comparing midazolam with guaifenesin when used in combination with an alpha-2 agonist and ketamine to maintain anaesthesia via i.v. infusion in horses. OBJECTIVES: To compare ketamine-medetomidine-guaifenesin with ketamine-medetomidine-midazolam for total intravenous anaesthesia (TIVA) in young horses anaesthetised for computerised tomography. STUDY DESIGN: Prospective, randomised, blinded, crossover trial. METHODS: Fourteen weanlings received medetomidine 7 µg/kg bwt i.v. and anaesthesia was induced with ketamine 2.2 mg/kg bwt i.v. On two separate occasions horses each received infusions of ketamine 3 mg/kg bwt/h, medetomidine 5 µg/kg bwt/h, guaifenesin 100 mg/kg bwt/h (KMG) or ketamine 3 mg/kg bwt/h, medetomidine 5 µg/kg bwt/h, midazolam 0.1 mg/kg bwt/h (KMM) for 50 min. Cardiorespiratory variables and anaesthetic depth were assessed every 5-10 min. Recovery times after the infusions ceased were recorded and recovery quality was assessed using a composite score system (CSS), simple descriptive scale (SDS) and visual analogue scale (VAS). Multivariable models were used to generate mean recovery scores for each treatment and each recovery score system and provide P-values comparing treatment groups. RESULTS: Anaesthesia was uneventful with no difference in additional anaesthetic requirements and little clinically relevant differences in cardiopulmonary variables between groups. All horses recovered without incident with no significant difference in recovery times. Quality of the anaesthetic recovery was significantly better for the KMM group compared with the KMG group using the CSS (P<0.001), SDS (P<0.001) and VAS (P<0.001). MAIN LIMITATIONS: No surgical stimulus was applied and study animals may not represent general horse population. CONCLUSION: Midazolam is a suitable alternative to guaifenesin when co-infused with ketamine and medetomidine for anaesthesia in young horses undergoing noninvasive procedures. Both infusions produce a clinically comparable quality of anaesthesia; however, recovery from anaesthesia is of a better quality following an infusion of ketamine-medetomidine-midazolam.


Subject(s)
Anesthetics, Intravenous/pharmacology , Guaifenesin/pharmacology , Horses , Ketamine/pharmacology , Medetomidine/pharmacology , Midazolam/pharmacology , Anesthesia, Intravenous/veterinary , Anesthetics, Intravenous/administration & dosage , Animals , Cross-Over Studies , Drug Therapy, Combination , Expectorants/administration & dosage , Expectorants/pharmacology , Female , Guaifenesin/administration & dosage , Hypnotics and Sedatives/administration & dosage , Ketamine/administration & dosage , Male , Medetomidine/administration & dosage , Midazolam/administration & dosage , Random Allocation , Tomography, X-Ray Computed/veterinary
13.
Med Phys ; 35(3): 950-8, 2008 Mar.
Article in English | MEDLINE | ID: mdl-18404931

ABSTRACT

A precision experimental investigation of the effective point of measurement (EPOM) of ion chambers in megavoltage beams has been carried out. A one-dimensional scanning phantom system was developed with an overall accuracy in the positioning of a chamber of better than 0.15 mm. Depth-dose data were acquired for a 25 MV beam from an Elekta Precise linac (field sizes of 10 x 10 cm and 25 x 25 cm) for measurement depths in the range 0.6-6 cm. The results confirmed the Monte Carlo calculations of an earlier theoretical investigation by Kawrakow [Med. Phys. 33, 1829-1839 (2006)] that the standard shift for cylindrical chambers, recommended in dosimetry protocols of -0.6r (where r is the internal radius of the cavity), is incorrect. A wide range of ion chambers were investigated and it was found that errors of up to 1.4 mm could occur for certain chamber designs (although typical errors for common chambers were around 0.5 mm). A comparison between measurements and Monte Carlo simulations showed that once the correct EPOM is used, the details of the linac geometry are correct, and the parameters of the electron beam striking the bremsstrahlung target have been adequately determined, the EGSnrc Monte Carlo package is capable of reproducing the experimental data to 0.2 mm or better. The investigation also confirmed that for the highest accuracy depth-dose curves in megavoltage photon beams one should use a well-guarded parallel-plate ion chamber. Three chamber designs were tested here and found to be satisfactory-the Scanditronix-Wellhöfer NACP-02, PTW Roos and Exradin All.


Subject(s)
Radiometry/instrumentation , Ions/analysis , Ions/chemistry , Monte Carlo Method , Reproducibility of Results , Uncertainty , X-Rays
14.
Med Phys ; 35(9): 4121-31, 2008 Sep.
Article in English | MEDLINE | ID: mdl-18841865

ABSTRACT

To model the transport of electrons through material requires knowledge of how the electrons lose energy and scatter. Theoretical models are used to describe electron energy loss and scatter and these models are supported by a limited amount of measured data. The purpose of this work was to obtain additional data that can be used to test models of electron scattering. Measurements were carried out using 13 and 20 MeV pencil beams of electrons produced by the National Research Council of Canada research accelerator. The electron fluence was measured at several angular positions from 0 degree to 90 degrees for scattering foils of different thicknesses and with atomic numbers ranging from 4 to 79. The angle, theta 1/e at which the fluence has decreased to 1/e of its value on the central axis was used to characterize the distributions. Measured values of theta 1/e ranged from 1.5 degrees to 8 degrees with a typical uncertainty of about 1%. Distributions calculated using the EGSnrc Monte Carlo code were compared to the measured distributions. In general, the calculated distributions are narrower than the measured ones. Typically, the difference between the measured and calculated values of theta 1/e is about 1.5%, with the maximum difference being 4%. The measured and calculated distributions are related through a simple scaling of the angle, indicating that they have the same shape. No significant trends with atomic number were observed.


Subject(s)
Electrons , Metals/chemistry , Particle Accelerators , Scattering, Radiation
15.
Med Phys ; 33(4): 876-87, 2006 Apr.
Article in English | MEDLINE | ID: mdl-16696463

ABSTRACT

The material Virtual Water has been characterized in photon and electron beams. Range-scaling factors and fluence correction factors were obtained, the latter with an uncertainty of around 0.2%. This level of uncertainty means that it may be possible to perform dosimetry in a solid phantom with an accuracy approaching that of measurements in water. Two formulations of Virtual Water were investigated with nominally the same elemental composition but differing densities. For photon beams neither formulation showed exact water equivalence-the water/Virtual Water dose ratio varied with the depth of measurement with a difference of over 1% at 10 cm depth. However, by using a density (range) scaling factor very good agreement (<0.2%) between water and Virtual Water at all depths was obtained. In the case of electron beams a range-scaling factor was also required to match the shapes of the depth dose curves in water and Virtual Water. However, there remained a difference in the measured fluence in the two phantoms after this scaling factor had been applied. For measurements around the peak of the depth-dose curve and the reference depth this difference showed some small energy dependence but was in the range 0.1%-0.4%. Perturbation measurements have indicated that small slabs of material upstream of a detector have a small (<0.1% effect) on the chamber reading but material behind the detector can have a larger effect. This has consequences for the design of experiments and in the comparison of measurements and Monte Carlo-derived values.


Subject(s)
Electrons/therapeutic use , Photons/therapeutic use , Radiometry/methods , Radiotherapy, High-Energy/methods , Water/chemistry , Materials Testing , Phantoms, Imaging , Radiation Dosage , Scattering, Radiation
16.
Med Phys ; 32(9): 2918-27, 2005 Sep.
Article in English | MEDLINE | ID: mdl-16266106

ABSTRACT

This article presents an investigation of the influence of the ion chamber response, including buildup caps, on the measurement of in-air off-axis ratio (OAR) profiles in megavoltage photon beams using Monte Carlo simulations with the EGSnrc system. Two new techniques for the calculation of OAR profiles are presented. Results of the Monte Carlo simulations are compared to measurements performed in 6, 10 and 25 MV photon beams produced by an Elekta Precise linac and shown to agree within the experimental and simulation uncertainties. Comparisons with calculated in-air kerma profiles demonstrate that using a plastic mini phantom gives more accurate air-kerma measurements than using high-Z material buildup caps and that the variation of chamber response with distance from the central axis must be taken into account.


Subject(s)
Particle Accelerators/instrumentation , Photons , Radiotherapy, High-Energy , Algorithms , Monte Carlo Method , Scattering, Radiation
17.
Phys Med Biol ; 50(13): N121-33, 2005 Jul 07.
Article in English | MEDLINE | ID: mdl-15972973

ABSTRACT

Dosimetry protocols recommend that ionization chambers used in radiation therapy be pre-irradiated until they 'settle', i.e., until a stable reading is obtained. Previous reports have claimed that a lack of pre-irradiation could result in errors up to several per cent. Recently, data collected for a large number of commonly used ion chambers at the Institute for National Measurement Standards, NRC, Canada, have been collated and analysed, with additional data contributed by the National Physical Laboratory, UK. With this data set, it was possible to relate patterns of ion chamber behaviour to design parameters. While several mechanisms seem to contribute to this behaviour, the most obvious correlations implicate the type of insulator surrounding the central collector electrode, the extent of collector electrode shielding and possibly the area of the insulator exposed at the base of the active air volume. The results show that ion chambers with electrode connections guarded up to the active air volume settle quickly (approximately 9 min) and the change in response is small (less than approximately 0.2%). For ion chambers where the guard connection surrounding the central collector does not extend up to the active air volume, settling times of 15-20 min and an associated change in response of up to 1% are typical. For some models of ion chambers, the irradiation rate may also play a role in settling behaviour. Settling times for the ion chambers studied here were found to be independent of beam quality.


Subject(s)
Artifacts , Quality Assurance, Health Care/methods , Radiation Protection/instrumentation , Radiometry/instrumentation , Radiotherapy/instrumentation , Dose-Response Relationship, Radiation , Radiation Dosage , Radiation Protection/methods , Radiation, Ionizing , Radiometry/methods , Reproducibility of Results , Sensitivity and Specificity
18.
Phys Med Biol ; 50(6): 1119-29, 2005 Mar 21.
Article in English | MEDLINE | ID: mdl-15798312

ABSTRACT

The energy dependence of alanine/EPR dosimetry for 8, 12, 18 and 22 MeV clinical electron beams was investigated by experiment and by Monte Carlo simulations. Alanine pellets in a waterproof holder were irradiated in a water phantom using an Elekta Precise linear accelerator. The dose rates at the reference point were determined following the TG-51 protocol using an NACP-02 parallel-plate chamber calibrated in a (60)Co beam. The EPR spectra of irradiated pellets were measured using a Bruker EMX 081 EPR spectrometer. Experimentally, we found no significant change in alanine/EPR response to absorbed dose-to-water over the energy range 8-22 MeV at an uncertainty level of 0.6%. However, the response for high-energy electrons is about 1.3 (+/-1.1)% lower than for (60)Co. The EGSnrc Monte Carlo system was used to calculate the ratio of absorbed dose-to-alanine to absorbed dose-to-water and it was shown that there is 1.3 (+/-0.2)% reduction in this ratio from the (60)Co beam to the electron beams, which confirms the experimental results. Alanine/EPR response per unit absorbed dose-to-alanine was also investigated and it is the same for high-energy electrons and (60)Co gamma-rays.


Subject(s)
Alanine/radiation effects , Brachytherapy/instrumentation , Cobalt Radioisotopes/analysis , Cobalt Radioisotopes/therapeutic use , Electron Spin Resonance Spectroscopy/instrumentation , Radiometry/instrumentation , Radiotherapy Planning, Computer-Assisted/instrumentation , Brachytherapy/methods , Computer Simulation , Electron Spin Resonance Spectroscopy/methods , Equipment Design , Equipment Failure Analysis , Linear Energy Transfer , Models, Biological , Models, Statistical , Monte Carlo Method , Radiometry/methods , Radiopharmaceuticals/analysis , Radiopharmaceuticals/therapeutic use , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods
19.
Phys Med Biol ; 60(4): 1641-54, 2015 Feb 21.
Article in English | MEDLINE | ID: mdl-25622289

ABSTRACT

In this study, a quantitative estimate is derived for the uncertainty in the XCOM photon mass attenuation coefficients in the energy range of interest to external beam radiation therapy-i.e. 100 keV (orthovoltage) to 25 MeV-using direct comparisons of experimental data against Monte Carlo models and theoretical XCOM data. Two independent datasets are used. The first dataset is from our recent transmission measurements and the corresponding EGSnrc calculations (Ali et al 2012 Med. Phys. 39 5990-6003) for 10-30 MV photon beams from the research linac at the National Research Council Canada. The attenuators are graphite and lead, with a total of 140 data points and an experimental uncertainty of ∼0.5% (k = 1). An optimum energy-independent cross section scaling factor that minimizes the discrepancies between measurements and calculations is used to deduce cross section uncertainty. The second dataset is from the aggregate of cross section measurements in the literature for graphite and lead (49 experiments, 288 data points). The dataset is compared to the sum of the XCOM data plus the IAEA photonuclear data. Again, an optimum energy-independent cross section scaling factor is used to deduce the cross section uncertainty. Using the average result from the two datasets, the energy-independent cross section uncertainty estimate is 0.5% (68% confidence) and 0.7% (95% confidence). The potential for energy-dependent errors is discussed. Photon cross section uncertainty is shown to be smaller than the current qualitative 'envelope of uncertainty' of the order of 1-2%, as given by Hubbell (1999 Phys. Med. Biol 44 R1-22).


Subject(s)
Algorithms , Photons , Radiotherapy Planning, Computer-Assisted/methods , Monte Carlo Method , Particle Accelerators , Radiation Dosage , Uncertainty
20.
Lymphat Res Biol ; 13(2): 131-6, 2015 Jun.
Article in English | MEDLINE | ID: mdl-26091409

ABSTRACT

BACKGROUND: The Indurometer is a tool designed by the Flinders Biomedical Engineering Department to replace the Tissue Tonometer. It measures the resistance to an applied force to quantify the amount of fibrosis present within the epifascial compartment of tissue. The aim of the study was to compare the current model of the Indurometer with the Tonometer to determine the level of variability and repeatability between the two devices and how the variability differs when compared to an individual's ISL stage. METHODS AND RESULTS: Data were gathered on a total of 180 participants with unilateral arm lymphedema as part of an international multicenter trial. For each participant three repeat measurements were obtained with the Indurometer and Tonometer at the anterior mid forearm and anterior mid upper arm. The Indurometer gave lower measurement values than the Tonometer. The Tonometer was found to be less variable than the Indurometer when measurements were taken from the anterior mid upper arm and the anterior mid forearm site. The Tonometer values were significantly less variable than the Indurometer values in ISL stages 1 and 2. No significant variability was found in stage 3. CONCLUSION: The Indurometer is easier to use as compared to the Tonometer. Modification of the Indurometer needs to take place in order to improve its variability before it can be considered as a replacement for the Tonometer in the assessment of lymphedema. The lack of understanding of the ISL classification system is a significant issue.


Subject(s)
Lymphedema/diagnosis , Manometry/instrumentation , Manometry/methods , Aged , Arm/anatomy & histology , Arm/pathology , Cross-Sectional Studies , Female , Humans , Male , Middle Aged , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL