Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Eur Radiol ; 25(4): 1005-13, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25500962

ABSTRACT

OBJECTIVES: Risks associated with high cumulative effective dose (CED) from radiation are greater when imaging is performed on younger patients. Testicular cancer affects young patients and has a good prognosis. Regular imaging is standard for follow-up. This study quantifies CED from diagnostic imaging in these patients. METHODS: Radiological imaging of patients aged 18-39 years, diagnosed with testicular cancer between 2001 and 2011 in two tertiary care centres was examined. Age at diagnosis, cancer type, dose-length product (DLP), imaging type, and frequency were recorded. CED was calculated from DLP using conversion factors. Statistical analysis was performed with SPSS. RESULTS: In total, 120 patients with a mean age of 30.7 ± 5.2 years at diagnosis had 1,410 radiological investigations. Median (IQR) surveillance was 4.37 years (2.0-5.5). Median (IQR) CED was 125.1 mSv (81.3-177.5). Computed tomography accounted for 65.3 % of imaging studies and 98.3 % of CED. We found that 77.5 % (93/120) of patients received high CED (>75 mSv). Surveillance time was associated with high CED (OR 2.1, CI 1.5-2.8). CONCLUSIONS: Survivors of testicular cancer frequently receive high CED from diagnostic imaging, mainly CT. Dose management software for accurate real-time monitoring of CED and low-dose CT protocols with maintained image quality should be used by specialist centres for surveillance imaging. KEY POINTS: • CT accounted for 98.3 % of CED in patients with testicular cancer. • Median CED in patients with testicular cancer was 125.1 mSv • High CED (>75 mSv) was observed in 77.5 % (93/120) of patients. • Dose tracking and development of low-dose CT protocols are recommended.


Subject(s)
Diagnostic Imaging , Neoplasms, Germ Cell and Embryonal/diagnostic imaging , Testicular Neoplasms/diagnostic imaging , Tomography, X-Ray Computed/methods , Adult , Humans , Male , Radiation Dosage
2.
Abdom Imaging ; 40(2): 251-7, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25139642

ABSTRACT

PURPOSE: Pure iterative reconstruction (Pure IR) has been proposed as a solution to improve diagnostic quality of low dose CT images. We assess the performance of model based iterative reconstruction (MBIR) in improving conventional dose CT enterography (CTE) images. METHODS: 43 Crohn's patients (27 female) (38.5 ± 12.98 years) referred for CTE were included. Images were reconstructed with pure IR (MBIR, General Electric Healthcare) in addition to standard department protocol (reconstructed with hybrid iterative reconstruction (Hybrid IR) [60% filtered back projection/40% adaptive statistical IR (General Electric Healthcare)]. Image quality was assessed objectively and subjectively at 6 anatomical levels. Clinical interpretation was undertaken in consensus by 2 blinded radiologists along with 2 non-blinded readers ('gold standard'). Results were analyzed using Statistical Package for Social Scientists. RESULTS: Mean effective radiation dose was 6.05 ± 2.84 mSv (size specific dose estimates 9.25 ± 2.9 mGy). Objective and subjective assessment yielded 6106 data points. Pure IR images significantly outperformed those using standard reconstruction techniques across all subjective (p < 0.001 for all comparisons) (noise, contrast resolution, spatial resolution, streak artifact, axial diagnostic acceptability, coronal diagnostic acceptability) and objective (p < 0.004) (noise, signal-to-noise ratio) parameters. Clinical reads of the pure IR images agreed more closely with the gold standard reads than the hybrid IR image reads in terms of overall Crohn's activity grade (κ = 0.630, 0.308) and detection of acute complications (κ = 1.0, 0.896). Results were comparable for bowel wall disease severity assessment (κ = 0.523, 0.593). CONCLUSIONS: Pure IR considerably improves image quality of conventional dose CTE images and therefore its use should be expanded beyond low dose protocols to improving image quality at conventional dose CT imaging.


Subject(s)
Crohn Disease/diagnostic imaging , Image Processing, Computer-Assisted/methods , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted , Tomography, X-Ray Computed , Adolescent , Adult , Aged , Contrast Media , Female , Gastrointestinal Tract/diagnostic imaging , Humans , Iohexol , Male , Middle Aged , Prospective Studies , Radiographic Image Enhancement , Reproducibility of Results , Sensitivity and Specificity , Young Adult
3.
Emerg Radiol ; 22(1): 25-9, 2015 Feb.
Article in English | MEDLINE | ID: mdl-24985783

ABSTRACT

The purpose of this study is to describe our initial clinical experience with dual-energy computed tomography (DECT) virtual non-calcium (VNC) images for the detection of bone marrow (BM) edema in patients with suspected hip fracture following trauma. Twenty-five patients presented to the emergency department at a level 1 trauma center between January 1, 2011 and January 1, 2013 with clinical suspicion of hip fracture and normal radiographs were included. All CT scans were performed on a dual-source, dual-energy CT system. VNC images were generated using prototype software and were compared to regular bone reconstructions by two musculoskeletal radiologists in consensus. Radiological and/or clinical diagnosis of fracture at 30-day follow-up was used as the reference standard. Twenty-one patients were found to have DECT-VNC signs of bone marrow edema. Eighteen of these 21 patients were true positive and three were false positive. A concordant fracture was clearly seen on bone reconstruction images in 15 of the 18 true positive cases. In three cases, DECT-VNC was positive for bone marrow edema where bone reconstruction CT images were negative. Four patients demonstrated no DECT-VNC signs of bone marrow edema: two cases were true negative, two cases were false negative. When compared with the gold standard of hip fracture determined at retrospective follow-up, the sensitivity of DECT-VNC images of the hip was 90 %, specificity was 40 %, positive predictive value was 86 %, and negative predictive value was 50 %. Our initial experience would suggest that DECT-VNC is highly sensitive but poorly specific in the diagnosis of hip fractures in patients with normal radiographs. The value of DECT-VNC primarily lies in its ability to help detect fractures which may be subtle or undetectable on bone reconstruction CT images.


Subject(s)
Algorithms , Bone Marrow/diagnostic imaging , Edema/diagnostic imaging , Hip Fractures/diagnostic imaging , Tomography, X-Ray Computed/methods , Adult , Aged , Aged, 80 and over , Diagnosis, Differential , Emergency Service, Hospital , False Negative Reactions , False Positive Reactions , Female , Humans , Male , Middle Aged , Radiographic Image Interpretation, Computer-Assisted , Sensitivity and Specificity
4.
West Indian Med J ; 57(5): 511-4, 2008 Nov.
Article in English | MEDLINE | ID: mdl-19565986

ABSTRACT

As the goal to eradicate wild polio virus (WPV) is approached, outbreaks associated with vaccine derived polioviruses (VDPV) with neurovirulent properties have emerged. The relevance for the spread of infection by nonparalytic cVDPV cases, with mutations associated with neurovirulence, is discussed with reference to the molecular analysis of a VDPV isolated from a Jamaican child who presented with aseptic meningitis. Potential risks to the Jamaican community resulting from circulation of cVDPV and critical factors defined by the World Health Organization (WHO) in the global eradication of Polio are analyzed in the context of immunization coverage, and the need to stop all Oral Polio Vaccine (OPV) use once wild polioviruses (WPVs) have been eradicated.


Subject(s)
Poliomyelitis/epidemiology , Poliomyelitis/prevention & control , Poliovirus Vaccine, Oral/adverse effects , Poliovirus , Vaccination/adverse effects , Child, Preschool , Humans , Immunization Programs , Jamaica , Male , Poliovirus/pathogenicity , Poliovirus Vaccine, Oral/administration & dosage , Risk Factors
5.
Insights Imaging ; 5(2): 217-30, 2014 Apr.
Article in English | MEDLINE | ID: mdl-24500656

ABSTRACT

OBJECTIVES: The aim was to assess the performance of low-dose non-contrast CT of the urinary tract (LD-CT) acquired at radiation exposures close to that of abdominal radiography using adaptive statistical iterative reconstruction (ASiR). METHODS: Thirty-three patients with clinically suspected renal colic were prospectively included. Conventional dose (CD-CT) and LD-CT data sets were contemporaneously acquired. LD-CT images were reconstructed with 40 %, 70 % and 90 % ASiR. Image quality was subjectively and objectively measured. Images were also clinically interpreted. RESULTS: Mean ED was 0.48 ± 0.07 mSv for LD-CT compared with 4.43 ± 3.14 mSv for CD-CT. Increasing the percentage ASiR resulted in a step-wise reduction in mean objective noise (p < 0.001 for all comparisons). Seventy % ASiR LD-CT images had higher diagnostic acceptability and spatial resolution than 90 % ASiR LD-CT images (p < 0.001). Twenty-seven calculi (diameter = 5.5 ± 1.7 mm), including all ureteric stones, were correctly identified using 70 % ASiR LD-CT with two false positives and 16 false negatives (diameter = 2.3 ± 0.7 mm) equating to a sensitivity and specificity of 72 % and 94 %. Seventy % ASiR LD-CT had a sensitivity and specificity of 87 % and 100 % for detection of calculi >3 mm. CONCLUSION: Reconstruction of LD-CT images with 70 % ASiR resulted in superior image quality than FBP, 40 % ASIR and 90 % ASIR. LD-CT with ASIR demonstrates high sensitivity and specificity for detection of calculi >3 mm. TEACHING POINTS: • Low-dose CT studies for urinary calculus detection were performed with a mean dose of 0.48 ± 0.07 mSv • Low-dose CT with 70 % ASiR detected calculi >3 mm with a sensitivity and specificity of 87 % and 100 % • Reconstruction with 70 % ASiR was superior to filtered back projection, 40 % ASiR and 90 % ASiR images.

6.
Br J Radiol ; 85(1017): 1222-5, 2012 Sep.
Article in English | MEDLINE | ID: mdl-22919005

ABSTRACT

On 11 March 2011, the Richter scale 0.9-magnitude Tokohu earthquake and tsunami struck the northeast coast of Japan, resulting in widespread injury and loss of life. Compounding this tragic loss of life, a series of equipment and structural failures at the Fukushima Dai-ichi nuclear power plant (FDNP) resulted in the release of many volatile radioisotopes into the atmosphere. In this update, we detail currently available evidence about the nature of immediate radioactive exposure to FDNP workers and the general population. We contrast the nature of the radioactive exposure at FDNP with that which occurred at the Chernobyl power plant 25 years previously. Prediction of the exact health effects related to the FDNP release is difficult at present and this disaster provides the scientific community with a challenge to help those involved and to continue research that will improve our understanding of the potential complications of radionuclide fallout.


Subject(s)
Earthquakes/statistics & numerical data , Nuclear Power Plants/statistics & numerical data , Occupational Exposure/statistics & numerical data , Radiation Monitoring/statistics & numerical data , Radioactive Hazard Release/statistics & numerical data , Radioisotopes/administration & dosage , Tsunamis/statistics & numerical data , Humans , Japan , Oceans and Seas
7.
Biochemistry ; 40(19): 5615-21, 2001 May 15.
Article in English | MEDLINE | ID: mdl-11341826

ABSTRACT

Ribulose-1,5-bisphosphate carboxylase/oxygenase (Rubisco) enzymes from different species differ with respect to carboxylation catalytic efficiency and CO2/O2 specificity, but the structural basis for these differences is not known. Whereas much is known about the chloroplast-encoded large subunit, which contains the alpha/beta-barrel active site, much less is known about the role of the nuclear-encoded small subunit in Rubisco structure and function. In particular, a loop between beta-strands A and B contains 21 or more residues in plants and green algae, but only 10 residues in prokaryotes and nongreen algae. To determine the significance of these additional residues, a mutant of the green alga Chlamydomonas reinhardtii, which lacks both small-subunit genes, was used as a host for transformation with directed-mutant genes. Although previous studies had indicated that the betaA-betaB loop was essential for holoenzyme assembly, Ala substitutions at residues conserved among land plants and algae (Arg-59, Tyr-67, Tyr-68, Asp-69, and Arg-71) failed to block assembly or eliminate function. Only the Arg-71 --> Ala substitution causes a substantial decrease in holoenzyme thermal stability. Tyr-68 --> Ala and Asp-69 --> Ala enzymes have lower K(m)(CO2) values, but these improvements are offset by decreases in carboxylation V(max) values. The Arg-71 --> Ala enzyme has a decreased carboxylation V(max) and increased K(m)(CO2) and K(m)(O2) values, which account for an observed 8% decrease in CO2/O2 specificity. Despite the fact that Arg-71 is more than 20 A from the large-subunit active site, it is apparent that the small-subunit betaA-betaB loop region can influence catalytic efficiency and CO2/O2 specificity.


Subject(s)
Amino Acid Substitution/genetics , Arginine/genetics , Carbon Dioxide/metabolism , Chloroplasts/enzymology , Mutagenesis, Site-Directed , Oxygen/metabolism , Ribulose-Bisphosphate Carboxylase/genetics , Ribulose-Bisphosphate Carboxylase/metabolism , Amino Acid Sequence , Animals , Chlamydomonas reinhardtii/enzymology , Chlamydomonas reinhardtii/genetics , Chloroplasts/genetics , Chloroplasts/metabolism , Enzyme Stability/genetics , Hot Temperature , Kinetics , Molecular Sequence Data , Phenotype , Protein Structure, Secondary/genetics , Ribulose-Bisphosphate Carboxylase/antagonists & inhibitors , Substrate Specificity/genetics , Transformation, Genetic
SELECTION OF CITATIONS
SEARCH DETAIL