Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 31
Filter
1.
Sensors (Basel) ; 21(17)2021 Aug 27.
Article in English | MEDLINE | ID: mdl-34502673

ABSTRACT

In this research work, the gas sensing properties of halogenated chloroaluminum phthalocyanine (ClAlPc) thin films were studied at room temperature. We fabricated an air-stable ClAlPc gas sensor based on a vertical organic diode (VOD) with a porous top electrode by the solution process method. The surface morphology of the solution-processed ClAlPc thin film was examined by field emission scanning electron microscopy (FESEM) and atomic force microscopy (AFM). The proposed ClAlPc-based VOD sensor can detect ammonia (NH3) gas at the ppb level (100~1000 ppb) at room temperature. Additionally, the ClAlPc sensor was highly selective towards NH3 gas compared to other interfering gases (NO2, ACE, NO, H2S, and CO). In addition, the device lifetime was tested by storing the device at ambient conditions. The effect of relative humidity (RH) on the ClAlPc NH3 gas sensor was also explored. The aim of this study is to extend these findings on halogenated phthalocyanine-based materials to practical electronic nose applications in the future.

2.
Opt Express ; 28(18): 26137-26142, 2020 Aug 31.
Article in English | MEDLINE | ID: mdl-32906889

ABSTRACT

We propose and demonstrate a received-signal-strength (RSS) based visible light positioning (VLP) system using a low-cost organic photovoltaic cell (OPVC) receiver (Rx). The OPVC is a passive device without the need of external power supply. It could detect VLC signal and harvest energy. Our developed OPVC has a high power conversion efficiency (PCE) of 9.8%. The VLP system can be operated at a low illumination of 130 lux. The regression machine learning (ML) algorithm is used to enhance the positioning accuracy.

3.
Opt Express ; 24(2): A414-23, 2016 Jan 25.
Article in English | MEDLINE | ID: mdl-26832593

ABSTRACT

In this work, we investigate blade-coated organic interlayers at the rear surface of hybrid organic-silicon photovoltaics based on two small molecules: Tris(8-hydroxyquinolinato) aluminium (Alq(3)) and 1,3-bis(2-(4-tert-butylphenyl)-1,3,4-oxadiazol-5-yl) benzene (OXD-7). In particular, soluble Alq(3) resulting in a uniform thin film with a root-mean-square roughness < 0.2nm is demonstrated for the first time. Both devices with the Alq(3) and OXD-7 interlayers show notable enhancement in the open-circuit voltage and fill-factor, leading to a net efficiency increase by over 2% from the reference, up to 11.8% and 12.5% respectively. The capacitance-voltage characteristics confirm the role of the small-molecule interlayers resembling a thin interfacial oxide layer for the Al-Si Schottky barrier to enhance the built-in potential and facilitate charge transport. Moreover, the Alq(3) interlayer in optimized devices exhibits isolated phases with a large surface roughness, in contrast to the OXD-7 which forms a continuous uniform thin film. The distinct morphological differences between the two interlayers further suggest different enhancement mechanisms and hence offer versatile functionalities to the advent of hybrid organic-silicon photovoltaics.

4.
Opt Express ; 23(7): A204-10, 2015 Apr 06.
Article in English | MEDLINE | ID: mdl-25968786

ABSTRACT

The hybrid white light-emitting didoes (LED) with polyfluoren (PFO) polymer and quantum dot (QD) was investigated using dispensing method at the different correlated color temperature (CCT) for cool and warm color temperature. This result indicates that the hybrid white LED device has the higher luminous efficiency than the convention one, which could be attributed to the increased utilization rate of the UV light. Furthermore, the CIE 1931 coordinate of high quality white hybrid LED with different CCT range from 3000K to 9000K is demonstrated. Consequently, the angular-dependent CCT and the thermal issue of the hybrid white LED device were also analyzed in this study.

5.
Sensors (Basel) ; 14(9): 16287-95, 2014 Sep 02.
Article in English | MEDLINE | ID: mdl-25184492

ABSTRACT

In this study, we investigate the keys to obtain a sensitive ammonia sensor with high air stability by using a low-cost polythiophene diode with a vertical channel and a porous top electrode. Poly(3-hexylthiophene) (P3HT) and air-stable poly(5,5'-bis(3-dodecyl-2-thienyl)-2,2'-bithiophene) (PQT-12) are both evaluated as the active sensing layer. Two-dimensional current simulation reveals that the proposed device exhibits numerous connected vertical nanometer junctions (VNJ). Due to the de-doping reaction between ammonia molecules and the bulk current flowing through the vertical channel, both PQT-12 and P3HT VNJ-diodes exhibit detection limits of 50-ppb ammonia. The P3HT VNJ-diode, however, becomes unstable after being stored in air for two days. On the contrary, the PQT-12 VNJ-diode keeps an almost unchanged response to 50-ppb ammonia after being stored in air for 25 days. The improved storage lifetime of an organic-semiconductor-based gas sensor in air is successfully demonstrated.


Subject(s)
Ammonia/analysis , Conductometry/instrumentation , Gases/analysis , Organoselenium Compounds/chemistry , Semiconductors , Thiophenes/chemistry , Equipment Design , Equipment Failure Analysis , Transducers
6.
Anal Chem ; 85(6): 3110-7, 2013 Mar 19.
Article in English | MEDLINE | ID: mdl-23394145

ABSTRACT

We successfully demonstrate the first solid-state sensor to have reliable responses to breath ammonia of rat. For thioacetamide (TAA)-induced hepatopathy rats, we observe that the proposed sensor can detect liver that undergoes acute-moderate hepatopathy with a p-value less than 0.05. The proposed sensor is an organic diode with vertical nanojunctions produced by using low-cost colloidal lithography. Its simple structure and low production cost facilitates the development of point-of-care technology. We also anticipate that the study is a starting point for investigating sophisticated breath-ammonia-related disease models.


Subject(s)
Ammonia/chemistry , Chemical and Drug Induced Liver Injury/diagnosis , Nanostructures , Animals , Breath Tests/methods , Chemical and Drug Induced Liver Injury/metabolism , Female , Rats , Rats, Sprague-Dawley , Thioacetamide/toxicity
7.
ACS Appl Mater Interfaces ; 15(6): 7911-7918, 2023 Feb 15.
Article in English | MEDLINE | ID: mdl-36719898

ABSTRACT

Achieving large-area organic photovoltaic (OPV) modules with reasonable cost and performance is an important step toward commercialization. In this work, solution-processed conventional and inverted OPV modules with an area of 216 cm2 were fabricated by the blade coating method. Film uniformity was controlled by adjusting the fabrication parameters of the blade coating procedure. The influence of the concentration of the solutions of the interfacial materials on OPV module performance was investigated. For OPV modules based on the PM6:Y6 photoactive layer, a certificated power conversion efficiency (PCE) of 9.10% was achieved for the conventional OPV modules based on the TASiW-12 interfacial layer while a certificated PCE of 11.27% was achieved for the inverted OPV modules based on the polyethylenimine (PEI) interfacial layer. As for OPV modules based on a commercially available photoactive layer, PV-X Plus, a PCE of 8.52% was achieved in the inverted OPV modules. A halogen-free solvent, o-xylene, was used as the solvent for PV-X Plus, which makes the industrial production much more environmentally friendly.

8.
Anal Chim Acta ; 1206: 339729, 2022 May 08.
Article in English | MEDLINE | ID: mdl-35473878

ABSTRACT

In this work, we proposed a rapid and easy check of the drinking water pollution level due to bacteria growth by semiconductor gas sensor. Highly sensitive vertical channel organic ammonia gas sensor was used to detect the gases emitted from the polluted water, and then determined effective ammonia concentration according to its response. Residues from meat of fish, shrimp, and fruits were mashed and added to the clean water. The water samples were stored at 35 °C for natural decay. Initially the bacteria concentration was below 100 colony forming unit per ml (cfu/ml), then it increased to103 cfu/ml in 2 h and 105 cfu/ml in 4 h, which was beyond the drinking safety standard, 500 cfu/ml. At this gas level no bad odor can be sensed by human yet, however, the effective ammonia concentration of those samples rises to 300-500 ppb in 2 h. The amine gas sensor can therefore be used as a rapid check if the bacteria level inside the water is far over the safety standard.


Subject(s)
Drinking Water , Ammonia , Bacteria , Drinking Water/microbiology , Gases , Semiconductors , Water Microbiology
9.
Polymers (Basel) ; 14(22)2022 Nov 20.
Article in English | MEDLINE | ID: mdl-36433157

ABSTRACT

Bio-inspired materials have received significant interest in the development of flexible electronics due to their natural grid structures, especially natural leaf vein networks. In this work, a bio-inspired leaf vein-based flexible humidity sensor is demonstrated. The proposed sensor is composed of a leaf/Al/glycerin/Ag paste. The Al-deposited leaf vein networks are used as a bottom electrode with a resistance of around 100 Ω. The humidity sensor responds well to relative humidity (RH) levels ranging from 15% to 70% at room temperature. The fabricated humidity sensor exhibits an ultra-sensitive response to different humidity conditions due to the biodegradable insulating hygroscopic polymer (glycerin), specifically the ionic conductivity reaction. To further verify the presence of ionic conduction, the device performance is tested by doping NaCl salt into the hygroscopic polymer sensing layer. In addition, both the repeatability and flexibility of the sensor are tested under different bending angles (0°, 90°, 180°, and 360°). The bioinspired ultrasensitive humidity sensor with a biocompatible and biodegradable sensing layer holds great potential, especially for health care applications (e.g., respiratory monitoring) without causing any body harm.

10.
Nanoscale Res Lett ; 16(1): 45, 2021 Mar 11.
Article in English | MEDLINE | ID: mdl-33704602

ABSTRACT

We report response of photoluminescence (PL) from GaN nanowires without protection in solutions. The distinct response is not only toward pH but toward ionic concentration under same pH. The nanowires appear to be highly stable under aqueous solution with high ionic concentration and low pH value down to 1. We show that the PL has a reversible interaction with various types of acidic and salt solutions. The quantum states of nanowires are exposed to the external environment and have a direct physical interaction which depends on the anions of the acids. As the ionic concentration increases, the PL intensity goes up or down depending on the chemical species. The response results from a competition of change in surface band bending and charge transfer to redox level in solution. That of GaN films is reported for comparison as the effect of surface band bending can be neglected so that there are only slight variations in PL intensity for GaN films. Additionally, such physical interaction does not impact on the PL peaks in acids and salts, whereas there is a red shift on PL when the nanowires are in basic solution, say NH4OH, due to chemical etching occurred on the nanowires.

11.
ACS Omega ; 5(36): 23021-23027, 2020 Sep 15.
Article in English | MEDLINE | ID: mdl-32954152

ABSTRACT

A fine cylindrical chemical sensor tip is developed with optical fiber in the core, surrounded by a transparent cylinder of photopolymer Norland Optical Adhesive 61 (NOA 61), and covered by a polymer hydrogel mixed with sensing molecules. The overall diameter is as small as 1.5 mm. pH response is demonstrated using two approaches of sensing materials: (i) absorbing probe Phenol Red mixed with Rhodamine 6G fluorescent dye and (ii) 8-hydroxypyrene-1,3,6-trisulfonic acid fluorescent probe. Both the optical excitation and fluorescence signal collection are through the optical fibers. A time resolution of 10 s is achieved for pH variations. Good linearity is observed in the physiological range from pH 7.0 to pH 8.6 with reversible and reproducible outcomes. For in vitro urea measurement, the sensor tip can distinguish 1, 3, and 5 mM urea solution, which is a crucial range in saliva urea concentration. The miniaturized tip with such simple cylindrical symmetry is designed to detect vital signs during minimally invasive surgeries and can be potentially accompanied with endoscopes to enter human bodies.

12.
RSC Adv ; 10(48): 28766-28777, 2020 Aug 03.
Article in English | MEDLINE | ID: mdl-35520068

ABSTRACT

Improving the stability of large-area organic light-emitting diodes is very important for practical applications. The interfacial layer plays a crucial role to improve the electron injection characteristic. In this work, devices prepared by various solution-processed interfacial materials and thermal-evaporated CsF were compared. In the devices with active area of 2.25 mm × 2.25 mm, we found that the performance and lifetime of the device with solution-processed Liq interfacial layer was comparable with the device with thermal-evaporated CsF. However, for the devices with active area of 2.4 cm × 3.7 cm, the device based on thermal-evaporated CsF was the champion in both performance and lifetime. The influence of the thickness of CsF on the stability was investigated. The most stable blue fluorescent devices can be achieved when the thickness of CsF is about 0.1 nm, while the most stable green phosphorescent devices can be obtained by depositing 0.2 nm CsF. The best current efficiency for the blue fluorescent device is 4 cd A-1, while the best one for the green phosphorescent device is 22 cd A-1. Furthermore, burning points causing the failure of the devices were investigated by scanning electron microscopy, atomic force microscopy, thermography and secondary ion mass spectrometry. We demonstrated that burning points are defects, which can be observed after long-time operation, showing higher local temperature and fragmentary electrode.

13.
Biomedicines ; 8(11)2020 Oct 31.
Article in English | MEDLINE | ID: mdl-33142890

ABSTRACT

Chronic kidney disease (CKD) is a public health problem and its prevalence has increased worldwide; patients are commonly unaware of the condition. The present study aimed to investigate whether exhaled breath ammonia via vertical-channel organic semiconductor (V-OSC) sensor measurement could be used for rapid CKD screening. We enrolled 121 CKD stage 1-5 patients, including 19 stage 1 patients, 26 stage 2 patients, 38 stage 3 patients, 21 stage 4 patients, and 17 stage 5 patients, from July 2019 to January 2020. Demographic and laboratory data were recorded. The exhaled ammonia was collected and rapidly measured by the V-OSC sensor to correlate with kidney function. Results showed no significant difference in age, sex, body weight, hemoglobin, albumin level, and comorbidities in different CKD stage patients. Correlation analysis demonstrated a good correlation between breath ammonia and blood urea nitrogen levels, serum creatinine levels, and estimated glomerular filtration rate (eGFR). Breath ammonia concentration was significantly elevated with increased CKD stage compared with the previous stage (CKD stage 1/2/3/4/5: 636 ± 94; 1020 ± 120; 1943 ± 326; 4421 ± 1042; 12781 ± 1807 ppb, p < 0.05). The receiver operating characteristic curve analysis showed an area under the curve (AUC) of 0.835 (p < 0.0001) for distinguishing CKD stage 1 from other CKD stages at 974 ppb (sensitivity, 69%; specificity, 95%). The AUC was 0.831 (p < 0.0001) for distinguishing between patients with/without eGFR < 60 mL/min/1.73 m2 (cutoff 1187 ppb: sensitivity, 71%; specificity, 78%). At 886 ppb, the sensitivity increased to 80% but the specificity decreased to 69%. This value is suitable for kidney function screening. Breath ammonia detection with V-OSC is a real time, inexpensive, and easy to administer measurement device for screening CKD with reliable diagnostic accuracy.

14.
ACS Appl Mater Interfaces ; 12(22): 24984-24991, 2020 Jun 03.
Article in English | MEDLINE | ID: mdl-32367710

ABSTRACT

A metal-oxide material (indium zinc oxide [IZO]) device with near-infrared (NIR) laser annealing was demonstrated on both glass and bendable plastic substrates (polycarbonate, polyethylene, and polyethylene terephthalate). After only 60 s, the sheet resistance of IZO films annealed with a laser was comparable to that of thermal-annealed devices at temperatures in the range of 200-300 °C (1 h). XPS, ATR, and AFM were used to investigate the changes in the sheet resistance and correlate them to the composition and morphology of the thin film. Finally, the NIR-laser-annealed IZO films were demonstrated to be capable of detecting changes in humidity and serving as a highly sensitive gas sensor of hydrogen sulfide (in ppb concentration), with room-temperature operation on a bendable substrate.

15.
J Breath Res ; 14(3): 036002, 2020 04 28.
Article in English | MEDLINE | ID: mdl-32015218

ABSTRACT

Previous studies have shown that breath ammonia (breath-NH3) concentration is associated with blood urea nitrogen (BUN) levels. However, interindividual variations in breath-NH3 concentrations were observed. Thus, the present study aimed to assess the effect of oral cavity conditions on breath-NH3 concentration and to validate whether the measurement of breath-NH3 concentration is feasible in clinical settings. A total of 125 individuals, including patients with stage 3 to 5 chronic kidney disease (CKD3-5), those on dialysis, and healthy participants, were recruited. A nanostructured sensor was used to detect breath-NH3 concentrations. Pre- and post-gargling as well as pre- and post-hemodialysis (HD) breath-NH3, salivary pH, and salivary urea levels were measured. Breath-NH3, salivary urea, salivary pH, and BUN levels were positively correlated to each other. Breath-NH3 concentrations were associated with BUN levels (r = 0.43, p < 0.001) and were significantly higher in CKD3-5 (p < 0.005) and dialysis patients (p < 0.001) than in healthy participants. Higher correlation coefficients were noted between breath-NH3 concentrations and BUN levels during follow-up (r = 0.59-0.94, p < 0.05). When the cutoff value of breath-NH3 was set at 523.65 ppb, its sensitivity and specificity in predicting CKD (BUN level >24 mg dl-1) were 87.6% and 80.9%, respectively. Breath-NH3 concentrations decreased after HD (p < 0.001) and immediately after gargling (p < 0.01). Breath-NH3 concentration, which was affected by gargling, was correlated to BUN level. The measurement of breath-NH3 concentration using the nanostructured device may be used as a tool for CKD detection and personalized point-of-care for CKD and dialysis patients. The current study had a small sample size. Thus, further studies with a larger cohort must be conducted to validate the effect of oral factors on breath-NH3 concentration and to validate the benefit of breath-NH3 measurement.


Subject(s)
Ammonia/analysis , Blood Urea Nitrogen , Breath Tests/methods , Renal Dialysis , Renal Insufficiency, Chronic/blood , Adult , Breath Tests/instrumentation , Female , Humans , Hydrogen-Ion Concentration , Male , Middle Aged , ROC Curve , Renal Insufficiency, Chronic/diagnosis , Saliva/chemistry , Urea/analysis
16.
Biosens Bioelectron ; 162: 112230, 2020 Aug 15.
Article in English | MEDLINE | ID: mdl-32392152

ABSTRACT

Solid-state zinc ion sensor is developed with high enough resolution and reproducibility for the potential application in brain injury monitoring. An optical diffuser is incorporated into the zinc ion sensor based on optical fiber and hydrogel doped with the fluorescent zinc ion probe molecule meso-2,6-Dichlorophenyltripyrrinone (TPN-Cl2). The diffuser transforms the high-peak-intensity excitation light near the fiber end into a broad light with moderate local intensity to reduce the degradation of the probe molecule. Reversible detection can be reached for 1, 2, and 5 µM (10-6 Molar), with slopes 0.3, 0.6, and 0.8 respectively. This is the pathophysiological concentration range after brain injury. The sensor is applied to neuron-glial cultures and macrophage under the stimulation of lipopolysaccharide (LPS), KCl and oxygen/glucose deprivation (OGD) that reflect inflammation, depolarization and ischemia respectively, mimicking events after brain injury. The zinc ion level is raised to 4-5 µM after LPS treatment, and then reduced to <3 µM after the co-treatment with the herbal drug silymarin. The results suggest the conditions of the neural cells under stress can be monitored.


Subject(s)
Biosensing Techniques/methods , Fluorescent Dyes/chemistry , Hydrogels/chemistry , Neurons/cytology , Zinc/analysis , Animals , Cells, Cultured , Neuroglia/chemistry , Neuroglia/cytology , Neurons/chemistry , Optical Fibers , Rats
17.
J Nanosci Nanotechnol ; 9(3): 2076-80, 2009 Mar.
Article in English | MEDLINE | ID: mdl-19435084

ABSTRACT

In this study, we report the fabrication and characterization of organic/inorganic hybrid polymer light emitting diodes (PLEDs) made with ZnS-capped CdSe core/shell type nanocrystals and a light-emitting polymer poly[2-phenyl-3-(9,9-dihexylfluoren-2-yl)-1,4-phenylene vinylene]-co-[2-methoxy-5-(2'-ethylhexyloxy)-1,4-phenylene vinylene]. The device using pristine polymer as active layer emitted yellow light with a maximum brightness of 3949 cd/m2 and maximum external quantum efficiency of 0.27 cd/A at 10 V. After blending with the CdSe/ZnS quantum dots (QDs), the device showed a much higher brightness of 8192 cd/m2 and external quantum efficiency of 1.27 cd/A at 7 V, while the driving voltage was lowered. The experimental results revealed that CdSe/ZnS QDs act as a hole-blocker in the devices. More efficient electron-hole recombination process inside polymer layer results in large improvement in luminescence and efficiency.

18.
ACS Appl Mater Interfaces ; 11(33): 29901-29909, 2019 Aug 21.
Article in English | MEDLINE | ID: mdl-31353900

ABSTRACT

Kirigami graphene allows a two-dimensional material to transform into a three-dimensional structure, which constitutes an effective transparent electrode candidate for photovoltaic (PV) cells having a surface texture. The surface texture of an inverted pyramid was fabricated on a Si substrate using photolithography and wet etching, followed by metal-assisted chemical etching to obtain silicon nanowires on the surface of the inverted pyramid. Kirigami graphene with a cross-pattern array was prepared using photolithography and plasma etching on a copper foil. Then, kirigami graphene was transferred onto hybrid heterojunction PV cells with a poly(ethylene terephthalate)/silicone film. These cells consisted of poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS) as the p-type semiconductor, Si(100) as the inorganic n-type semiconductor, and a silver comb electrode on top of PEDOT:PSS. The conductivity of PEDOT:PSS was greatly improved. This improvement was significantly higher than that achieved by the continuous graphene sheet without a pattern. Transmission electron microscopy and Raman spectroscopy results revealed that the greater improvement with kirigami graphene was due to the larger contact area between PEDOT:PSS and graphene. By using two-layer graphene having a kirigami pattern, the power conversion efficiency, under simulated AM1.5G illumination conditions, was significantly augmented by up to 9.8% (from 10.03 to 11.01%).

19.
Biosens Bioelectron ; 132: 352-359, 2019 May 01.
Article in English | MEDLINE | ID: mdl-30897542

ABSTRACT

Salivary urea was reported to be a useful biomarker to reflect the blood urea nitrogen in chronic kidney disease patients. However, as a new biomarker, enormous clinical trials are required to define the intended-use and to verify the specification. In this report, we demonstrated a low-cost easy-operated real-time sensing system (optical fiber-urea-sensing, OFUS, system) to detect salivary urea. We aim to make the system easily reproduced by the community to stimulate abundant clinical tests worldwide. The OFUS system is composed of a simple three-dimensional printed tank to link with two optical fibers, one connecting with a commercial light-emitting diode to deliver the input light signal, the other connecting with a commercial cadmium sulfide photo-conductive cell to detect the sensing signal. To allow on-site detection without any sample pretreatment, only 1 µl saliva is needed to be mixed with 10 µl urease solution and 90 µl pH indicator solution in the reaction tank and the detection time is only 20 s. A stable and reproducible calibration curve can be easily built with a detection range as 24-300 mg/dL. The OFUS system successfully detected saliva with added synthetic urea and samples from chronic kidney disease patients. A good agreement between the OFUS system and the commercial kit was obtained. A good correlation between salivary urea and the blood urea nitrogen was also confirmed.


Subject(s)
Biosensing Techniques/instrumentation , Fiber Optic Technology/instrumentation , Point-of-Care Testing , Saliva/chemistry , Urea/analysis , Biosensing Techniques/economics , Equipment Design , Fiber Optic Technology/economics , Humans , Limit of Detection , Point-of-Care Testing/economics , Renal Insufficiency, Chronic/diagnosis , Urease/chemistry
20.
RSC Adv ; 9(19): 10584-10598, 2019 Apr 03.
Article in English | MEDLINE | ID: mdl-35515314

ABSTRACT

The electrical current leakage and stability are studied for solution-processed OLEDs with areas of 4.45 mm2, 3 × 3.2 cm2, and 6 × 11.5 cm2. The emission layer of the OLED has a ternary or binary mixed host with hole-transporting molecules tris(4-carbazoyl-9-ylphenyl)amine (TCTA) and 9-(4-tert-butylphenyl)-3,6-bis(triphenylsilyl)-9H-carbazole (CzSi), together with the electron-transporting molecule 2,7-bis(diphenylphosphoryl)-9,9'-spirobi[fluorene] (SPPO13). The phosphorescent emitters are Ir(mppy)3 for green and bis[4-(4-tert-butylphenyl)thieno[3,2-c]pyridine][N,N'-diisopropylbenamidinato]iridium(iii) (PR-02) for orange. Poly[(9,9-dioctylfluorenyl-2,7-diyl)-co-(4,4'-(N-(4-sec-butylphenyl))diphenylamine)] (TFB) is used as the hole transport layer and PEDOT:PSS is used as the hole injection layer. On top of the emission layer, CsF/Al is deposited by thermal evaporation as the cathode. All organic layers are deposited by blade coating and the initial current leaking defects can be avoided by careful control of the coating conditions. The detrimental burning point caused by a local current short developed after long-time operation can be avoided by reducing the operation voltage using a ternary mixed host. The operation voltage is only 4 V at 100 cd m-2 and 5 V at 250 cd m-2 for the green emitting device. Furthermore, the crystallization defect is reduced by the ternary host. For the orange emitting device, the binary host is good enough with an operating voltage of 5 V at 100 cd m-2. For an area as large as 6 × 11.5 cm2, the OLED shows good stability and there is no burning point after an operation of over 1600 hours.

SELECTION OF CITATIONS
SEARCH DETAIL