Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters

Database
Language
Publication year range
1.
J Cardiovasc Electrophysiol ; 33(1): 117-122, 2022 01.
Article in English | MEDLINE | ID: mdl-34674347

ABSTRACT

INTRODUCTION: Single-center observational studies have shown promising results with fragmented electrogram (FE)-guided ganglionated plexus (GP) ablation in patients with vagally mediated bradyarrhythmia (VMB). We aimed to compare the acute procedural characteristics during FE-guided GP ablation in patients with VMB performed by first-time operators and those of a single high-volume operator. METHODS AND RESULTS: This international multicenter cohort study included data collected over 2 years from 16 cardiac hospitals. The primary operators were classified according to their prior GP ablation experience: a single high-volume operator who had performed > 50 GP ablation procedures (Group 1), and operators performing their first GP ablation cases (Group 2). Acute procedural characteristics and syncope recurrence were compared between groups. Forty-seven consecutive patients with VMB who underwent FE-guided GP ablation were enrolled, n = 31 in Group 1 and n = 16 in Group 2. The mean number of ablation points in each GP was comparable between groups. The ratio of positive vagal response during ablation on the left superior GP was higher in Group 1 (90.3% vs. 62.5%, p = .022). Ablation of the right superior GP increased heart rate acutely without any vagal response in 45 (95.7%) cases. The procedure time was longer in group 2 (83.4 ± 21 vs. 118.0 ± 21 min, respectively, p < .001). Over a mean follow-up duration of 8.0 ± 3 months (range 2-24 months), none of the patients suffered from syncope. CONCLUSION: This multi-center pilot study shows for the first time the feasibility of FE-guided GP ablation across a large group of procedure-naïve operators.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Atrial Fibrillation/surgery , Bradycardia/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Cohort Studies , Humans , Pilot Projects , Treatment Outcome , Vagus Nerve/surgery
2.
Korean Circ J ; 46(4): 580-3, 2016 Jul.
Article in English | MEDLINE | ID: mdl-27482270

ABSTRACT

Left atrial intramural hematoma is a very rare complication of radiofrequency ablation procedures. A patient with tachyarrhythmia underwent radiofrequency catheter ablation. Echocardiography performed the following morning showed a large mass in the left atrium, suggestive of intramural hematoma formation. The patient was in a stable condition; therefore, it was decided that follow-up should be conservative and her anticoagulation therapy was continued. The size of the hematoma decreased significantly over the following 50 days. This case highlights a rare complication of a complex catheter ablation procedure in the left atrium that was managed via a noninvasive approach, with which all interventionists should be familiar.

SELECTION OF CITATIONS
SEARCH DETAIL