Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters

Database
Language
Publication year range
1.
Hellenic J Cardiol ; 76: 31-39, 2024.
Article in English | MEDLINE | ID: mdl-37295667

ABSTRACT

OBJECTIVES: The study aimed to compare pre- and postoperative resting as well as postprocedural resting and exertional right ventricular speckle-tracking echocardiographic parameters at a mid-term follow-up after left ventricular assist device (LVAD) implantation. METHODS: Patients with implanted third-generation LVADs with hydrodynamic bearings were prospectively enrolled (NCT05063006). Myocardial deformation was evaluated before pump implantation and at least three months after the procedure, both at rest and during exercise. RESULTS: We included 22 patients, 7.3 months (IQR, 4.7-10.2) after the surgery. The mean age was 58.4 ± 7 years, 95.5% were men, and 45.5% had dilated cardiomyopathy. The RV strain analysis was feasible in all subjects both at rest and during exercise. The RV free wall strain (RVFWS) worsened from -13% (IQR, -17.3 to -10.9) to -11.3% (IQR, -12.9 to -6; p = 0.033) after LVAD implantation with a particular decline in the apical RV segment [-11.3% (IQR, -16.4 to -6.2) vs -7.8% (IQR, -11.7 to -3.9; p = 0.012)]. The RV four-chamber longitudinal strain (RV4CSL) remained unchanged [-8.5% (IQR, -10.8 to -6.9) vs -7.3% (IQR, -9.8 to -4.7; p = 0.184)]. Neither RVFWS (-11.3% (IQR, -12.9 to -6) vs -9.9% (IQR, -13.5 to -7.5; p = 0.077) nor RV4CSL [-7.3% (IQR, -9.8 to -4.7) vs -7.9% (IQR, -9.8 to -6.3; p = 0.548)] changed during the exercise test. CONCLUSIONS: In patients who are pump-supported, the right ventricular free wall strain tends to worsen after LVAD implantation and remains unchanged during a cycle ergometer stress test.


Subject(s)
Heart Failure , Heart-Assist Devices , Ventricular Dysfunction, Right , Aged , Female , Humans , Male , Middle Aged , Echocardiography/methods , Heart-Assist Devices/adverse effects , Retrospective Studies , Ventricular Dysfunction, Right/diagnostic imaging , Ventricular Dysfunction, Right/etiology , Ventricular Function, Left , Ventricular Function, Right
2.
Heart ; 108(13): 1055-1062, 2022 06 10.
Article in English | MEDLINE | ID: mdl-35314453

ABSTRACT

OBJECTIVE: Current generation left ventricular assist devices (LVADs) operate with a fixed rotation speed and no automated speed adjustment function. This study evaluates the concept of physiological pump speed optimisation based on aortic valve opening (AVO) imaging during a cardiopulmonary exercise test (CPET). METHODS: This prospective crossover study (NCT05063006) enrolled patients with implanted third-generation LVADs with hydrodynamic bearing. After resting speed optimisation, patients were randomised to a fixed-modified speed or modified-fixed speed CPET sequence. Fixed speed CPET maintained baseline pump settings. During the modified speed CPET, the LVAD speed was continuously altered to preserve periodic AVO. RESULTS: We included 22 patients, the mean age was 58.4±7 years, 4.5% were women and 54.5% had ischaemic cardiomyopathy. Exertional AVO assessment was feasible in all subjects. Maintaining periodic AVO allowed to safely raise the pump speed from 2900 (IQR 2640-3000) to 3440 revolutions per minute (RPM) (IQR 3100-3700; p<0.001). As a result, peak oxygen consumption increased from 11.1±2.4 to 12.8±2.8 mL/kg/min (p<0.001) and maximum workload from 1.1 (IQR 0.9-1.5) to 1.2 W/kg (IQR 0.9-1.7; p=0.028). The Borg scale exertion level decreased from 15.2±1.5 to 13.5±1.2 (p=0.005). CONCLUSIONS: Transthoracic AVO imaging is possible during CPETs in patients with LVAD. Dynamic echo-guided pump speed adjustment based on the AVO improves exercise tolerance and augments peak oxygen consumption and maximum workload.


Subject(s)
Heart Failure , Heart-Assist Devices , Aged , Cross-Over Studies , Exercise/physiology , Exercise Test , Female , Heart Failure/diagnosis , Heart Failure/therapy , Humans , Male , Middle Aged , Prospective Studies , Ventricular Function, Left/physiology
SELECTION OF CITATIONS
SEARCH DETAIL