Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Sensors (Basel) ; 23(18)2023 Sep 14.
Article in English | MEDLINE | ID: mdl-37765944

ABSTRACT

Spatial frequency domain imaging (SFDI) is well established in biology and medicine for non-contact, wide-field imaging of optical properties and 3D topography. Especially for turbid media with displaced, tilted or irregularly shaped surfaces, the reliable quantitative measurement of diffuse reflectance requires efficient calibration and correction methods. In this work, we present the implementation of a generic and hardware independent calibration routine for SFDI setups based on the so-called pinhole camera model for both projection and detection. Using a two-step geometric and intensity calibration, we obtain an imaging model that efficiently and accurately determines 3D topography and diffuse reflectance for subsequently measured samples, taking into account their relative distance and orientation to the camera and projector, as well as the distortions of the optical system. Derived correction procedures for position- and orientation-dependent changes in spatial frequency and intensity allow the determination of the effective scattering coefficient µs' and the absorption coefficient µa when measuring a spherical optical phantom at three different measurement positions and at nine wavelengths with an average error of 5% and 12%, respectively. Model-based calibration allows the characterization of the imaging properties of the entire SFDI system without prior knowledge, enabling the future development of a digital twin for synthetic data generation or more robust evaluation methods.

2.
Nanotechnology ; 24(46): 465709, 2013 Nov 22.
Article in English | MEDLINE | ID: mdl-24172909

ABSTRACT

We study the reversal mechanisms in a self-assembled, hexagonally ordered Fe antidot array with a period of 200 nm and an antidot diameter of 100 nm which was prepared by polystyrene nanosphere lithography. Direction-dependent information in such a self-assembled sample is obtained by measuring the anisotropic magnetoresistance (AMR) through constrictions processed by focused ion beam milling in nearest neighbor and next nearest neighbor directions. We show that such an originally integral method can be used to investigate the strong in-plane anisotropy introduced by the antidot lattice. The easy and hard axis reversal mechanisms and corresponding AMR signals are modeled by micromagnetic simulations. Additional in-field magnetic force microscopy studies allow the correlation of microscopic switching to features in the integral AMR. We find that the easy axis of magnetization is connected to a distinct periodic magnetic domain pattern, which can be observed during the whole magnetization reversal. While this process is driven by nucleation and propagation of reversed domains, the hard axis reversal is characterized by a (stepwise) rotation of the magnetization via the antidot lattice' easy axes.

3.
Dent Mater ; 37(2): 212-222, 2021 02.
Article in English | MEDLINE | ID: mdl-33267975

ABSTRACT

OBJECTIVES: Testing and comparing of different non-shaded zirconia materials (3Y-TZP, 4Y-TZP and 5Y-TZP) on optical and mechanical properties. MATERIALS AND METHODS: Zirconia materials (N = 320, Opaque O, Translucent T, Extra Translucent ET, High Translucent HT) were investigated on translucency, Martens parameter, biaxial flexural strength, Chevron-Notch-Beam (CNB) fracture toughness (KIC) and grain size. The grain size was analyzed using a scanning electron microcopy (SEM). Univariate ANOVA, post-hoc Scheffé, partial eta-squared, Kolmogorov-Smirnov-, Kruskal-Wallis- and Mann-Whitney-U-tests (p < 0.05) were performed. The reliability of flexural strength was calculated with two-parametric Weibull analysis and 95 % confidence level. RESULTS: The translucency of ET and HT increased with the thermo-mechanical aging (p < 0.001). The zirconia material and aging had no impact on the Martens hardness and the indentation modulus. ET showed the highest flexural strength values after initial and thermo-mechanical aging (p < 0.001 - 0.683). All four materials showed the highest flexural strength after thermo-mechanical aging after 1.2 Mio cycles. Thermo-mechanically (1.2 Mio cycles) aged HT presented the highest Weibull modulus (m = 15.0) regardless of aging. Within initial groups, T (p ≤ 0.001) showed the highest fracture toughness, followed by O (p ≤ 0.001), ET (p < 0.003) and HT (p ≤ 0.001). SIGNIFICANCE: Translucency of ET and HT increases with thermo-mechanical aging. Chevron-Notch-Beam (CNB) is a valid alternative to the single-edge-V-notched beam (SEVNB) method for testing fracture toughness.


Subject(s)
Dental Materials , Flexural Strength , Hardness , Materials Testing , Reproducibility of Results , Surface Properties , Zirconium
4.
J Biomed Opt ; 24(7): 1-10, 2018 09.
Article in English | MEDLINE | ID: mdl-30218505

ABSTRACT

A method to correct for surface scattering in spatial frequency domain imaging (SFDI) is presented. The use of a modified analytical solution of the radiative transfer equation allows calculation of the reflectance and the phase of a rough semi-infinite geometry so that both spatial frequency domain reflectance and phase can be applied for precise retrieval of the bulk optical properties and the surface scattering. For validation of the method, phantoms with different surface roughness were produced. Contrarily, with the modified theory, it was possible to dramatically reduce systematic errors due to surface scattering. The evaluation of these measurements with the state-of-the-art theory and measuring modality, i.e., using crossed linear polarizers, reveals large errors in the determined optical properties, depending on the surface roughness, of up to ≈100 % . These results were confirmed with SFDI measurements on a phantom that has a structured rough surface.


Subject(s)
Optical Imaging/methods , Scattering, Radiation , Light , Phantoms, Imaging , Surface Properties
5.
Phys Med Biol ; 60(3): 1171-83, 2015 Feb 07.
Article in English | MEDLINE | ID: mdl-25590919

ABSTRACT

Intralipid has become an extensively studied and widely used reference and calibration phantom for diffuse optical imaging technologies. In this study we call attention to the layering properties of Intralipid emulsions, which are commonly assumed to have homogeneous optical properties. By measurement of spatial frequency domain reflectance in combination with an analytical solution of the radiative transfer equation for two-layered media, we make quantitative investigations on the formation of a surface layer on different dilutions of Intralipid. Our findings are verified by an independent spatially resolved reflectance setup giving evidence of a time dependent, thin and highly scattering surface layer on top of Intralipid-water emulsions. This layer should be considered when using Intralipid as an optical calibration or reference phantom.


Subject(s)
Phantoms, Imaging , Phospholipids/chemistry , Soybean Oil/chemistry , Surface Properties , Calibration , Emulsions/chemistry , Nephelometry and Turbidimetry , Optical Imaging
6.
J Biomed Opt ; 20(11): 116006, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26590206

ABSTRACT

We demonstrate optical phantom experiments on the phase function parameter γ using spatial frequency domain imaging. The incorporation of two different types of scattering particles allows for control of the optical phantoms' microscopic scattering properties. By laterally structuring areas with either TiO2 or Al2O3 scattering particles, we were able to obtain almost pure subdiffusive scattering contrast in a single optical phantom. Optical parameter mapping was then achieved using an analytical radiative transfer model revealing the microscopic structural contrast on a macroscopic field of view. As part of our study, we explain several correction and referencing techniques for high spatial frequency analysis and experimentally study the sampling depth of the subdiffusive parameter γ.


Subject(s)
Nephelometry and Turbidimetry/instrumentation , Photometry/instrumentation , Refractometry/instrumentation , Scattering, Radiation , Spectrum Analysis/instrumentation , Tomography, Optical/instrumentation , Animals , Equipment Design , Equipment Failure Analysis , Humans , Light , Phantoms, Imaging , Reproducibility of Results , Sensitivity and Specificity
7.
J Biomed Opt ; 20(10): 105008, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26473589

ABSTRACT

A new epoxy-resin-based optical phantom system with adjustable subdiffusive scattering parameters is presented along with measurements of the intrinsic absorption, scattering, fluorescence, and refractive index of the matrix material. Both an aluminium oxide powder and a titanium dioxide dispersion were used as scattering agents and we present measurements of their scattering and reduced scattering coefficients. A method is theoretically described for a mixture of both scattering agents to obtain continuously adjustable anisotropy values g between 0.65 and 0.9 and values of the phase function parameter γ in the range of 1.4 to 2.2. Furthermore, we show absorption spectra for a set of pigments that can be added to achieve particular absorption characteristics. By additional analysis of the aging, a fully characterized phantom system is obtained with the novelty of g and γ parameter adjustment.


Subject(s)
Light , Phantoms, Imaging , Scattering, Radiation , Spectrum Analysis/instrumentation , Tomography, Optical/instrumentation , Absorption, Radiation , Diffusion , Equipment Design , Equipment Failure Analysis , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL