Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters

Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-38956821

ABSTRACT

BACKGROUND: Despite advances in efficacy and safety of pulmonary vein isolation (PVI), atrial fibrillation (AF) recurrence after PVI remains common. PV-reconnection is the main finding during repeat PVI procedures performed to treat recurrent AF. OBJECTIVE: To analyze pulmonary vein (PV) reconnection patterns during repeat ablation procedures in a large cohort of consecutive patients undergoing radio frequency or cryoballoon-based PVI. METHODS: Retrospective analysis of PV-reconnection patterns and analysis of re-ablation strategies in consecutive index RF- and CB-based PVI and their respective re-ablation procedures during concomitant usage of both energy sources at a single high-volume center in Germany. RESULTS: A total of 610 first (06/2015-10/2022) and 133 s (01/2016-11/2022) repeat ablation procedures after 363 (60%) RF- and 247 (40%) CB-based index PVIs between 01/2015 and 12/2021 were analyzed. PV-reconnection was found in 509/610 (83%) patients at first and 74/133 (56%) patients at second repeat procedure. 465 of 968 (48%) initially via CB isolated PVs were reconnected at first re-ablation but 796 of 1422 initially RF-isolated PV (56%) were reconnected (OR: 0.73 [95% CI: 0.62-0.86]; p < .001). This was driven by fewer reconnections of the left PVs (LSPV: OR: 0.60 [95% CI: 0.42-0.86]; p = .005 and LSPV: 0.67 [0.47-0.95]; p = .026). PV-reconnection was more likely after longer, RF-based index PVI and in older females. Repeat procedures were shorter after CB-compared to after RF-PVI. CONCLUSIONS: Reconnection remains the most common reason for repeat AF ablation procedures after PVI. Our data suggest to preferentially use of the cryoballoon during index PVI, especially in older women.

3.
Eur Heart J Digit Health ; 3(4): 610-625, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36710894

ABSTRACT

Aims: Simplified detection of atrial arrhythmias via consumer-electronics would enable earlier therapy in at-risk populations. Whether this is feasible and effective in older populations is not known. Methods and results: The fully remote, investigator-initiated Smartphone and wearable detected atrial arrhythmia in Older Adults Case finding study (Smart in OAC-AFNET 9) digitally enrolled participants ≥65 years without known atrial fibrillation, not receiving oral anticoagulation in Germany, Poland, and Spain for 8 weeks. Participants were invited by media communications and direct contacts. Study procedures adhered to European data protection. Consenting participants received a wristband with a photoplethysmography sensor to be coupled to their smartphone. The primary outcome was the detection of atrial arrhythmias lasting 6 min or longer in the first 4 weeks of monitoring. Eight hundred and eighty-two older persons (age 71 ± 5 years, range 65-90, 500 (57%) women, 414 (47%) hypertension, and 97 (11%) diabetes) recorded signals. Most participants (72%) responded to adverts or word of mouth, leaflets (11%) or general practitioners (9%). Participation was completely remote in 469/882 persons (53%). During the first 4 weeks, participants transmitted PPG signals for 533/696 h (77% of the maximum possible time). Atrial arrhythmias were detected in 44 participants (5%) within 28 days, and in 53 (6%) within 8 weeks. Detection was highest in the first monitoring week [incidence rates: 1st week: 3.4% (95% confidence interval 2.4-4.9); 2nd-4th week: 0.55% (0.33-0.93)]. Conclusion: Remote, digitally supported consumer-electronics-based screening is feasible in older European adults and identifies atrial arrhythmias in 5% of participants within 4 weeks of monitoring (NCT04579159).

SELECTION OF CITATIONS
SEARCH DETAIL