Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters

Database
Language
Publication year range
1.
Rev Cubana Med Trop ; 51(2): 99-105, 1999.
Article in Spanish | MEDLINE | ID: mdl-10887568

ABSTRACT

An indirect ELISA test was optimised in which B meningoccocus outer membrane proteins included in the Cuban Vaccine known as VA-MENGOC-BC were used as capture antigents. Specific antibodies in serum samples from vaccinated individuals were detected using a human anti-IgG conjugate, i.e. alklayne phosphatase, thus the reaction developed with a specific substrate called p-nitrophenilphophate. Standard serum was obtained from a reference standard, the gage curve range was 625 to 20,000/mL. The control serum was selected from the most interesting areas for the samples, hence, assay characteristics were determined. Intra-assay, inter-assay and total inaccuracies were lower than 10% in the most linear area of the curve. Detectability was 700/mL. Recovery, paralelism and linearity studies showed an under 10% inaccuracy.


Subject(s)
Bacterial Proteins/immunology , Enzyme-Linked Immunosorbent Assay , Immunoglobulin G/blood , Neisseria meningitidis/immunology , Humans , Neisseria meningitidis/classification , Reproducibility of Results , Serotyping
SELECTION OF CITATIONS
SEARCH DETAIL