Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters

Database
Language
Publication year range
1.
Appl Opt ; 53(32): 7664-76, 2014 Nov 10.
Article in English | MEDLINE | ID: mdl-25402988

ABSTRACT

The new Japanese x-ray astronomy satellite, ASTRO-H, will carry two identical hard x-ray telescopes (HXTs), which cover the energy range of 5 to 80 keV. The HXT mirrors employ tightly nested, conically approximated thin-foil Wolter-I optics, and the mirror surfaces are coated with Pt/C depth-graded multilayers to enhance the hard x-ray effective area by means of Bragg reflection. The HXT comprises foils 120-450 mm in diameter and 200 mm in length, with a focal length of 12 m. To obtain a large effective area, 213 aluminum foils 0.2 mm in thickness are tightly nested confocally. The requirements for HXT are a total effective area of >300 cm2 at 30 keV and an angular resolution of <1.7' in half-power diameter (HPD). Fabrication of two HXTs has been completed, and the x-ray performance of each HXT was measured at a synchrotron radiation facility, SPring-8 BL20B2 in Japan. Angular resolutions (HPD) of 1.9' and 1.8' at 30 keV were obtained for the full telescopes of HXT-1 and HXT-2, respectively. The total effective area of the two HXTs at 30 keV is 349 cm2.


Subject(s)
Lenses , Spacecraft/instrumentation , Telescopes , X-Ray Diffraction/instrumentation , Computer-Aided Design , Equipment Design , Equipment Failure Analysis
2.
Appl Opt ; 42(10): 1856-66, 2003 Apr 01.
Article in English | MEDLINE | ID: mdl-12683767

ABSTRACT

The International Focusing Optics Collaboration for microCrab Sensitivity (InFOCmicroS) balloonborne hard x-ray telescope incorporates graded Pt/C multilayers replicated onto segmented Al foils to obtain the significant effective area at energies previously inaccessible to x-ray optics. Reflectivity measurements of individual foils demonstrate our capability to produce a mass quantity of multilayered foils with a rms roughness of 0.5 nm. The effective area of the completed mirror is 78 and 22 cm2 at 20 and 40 keV, respectively. The measured half-power diameter is 2.0 +/- 0.6 are min (90% confidence). The successful completion of this mirror demonstrates its applicability to future x-ray telescopes such as Constellation-X.

3.
Appl Opt ; 41(25): 5417-26, 2002 Sep 01.
Article in English | MEDLINE | ID: mdl-12211573

ABSTRACT

A hard-x-ray telescope is successfully produced for balloon observations by making use of depth-graded multilayers, or so-called supermirrors, with platinum-carbon (Pt/C) layer pairs. It consists of four quadrant units assembled in an optical configuration with a diameter of 40 cm and a focal length of 8 m. Each quadrant is made of 510 pieces of coaxially and confocally aligned supermirrors that significantly enhance the sensitivity in an energy range of 20-40 keV. The configuration of the telescope is similar to the x-ray telescope onboard Astro-E, but with a longer focal length. The reflectivity of supermirrors is of the order of 40% in the energy range concerned at a grazing angle of 0.2 deg. The effective area of a fully assembled telescope is 50 cm2 at 30 keV. The angular resolution is 2.37 arc min at half-power diameter 8.0 keV. The field of view is 12.6 arc min in the hard-x-ray region, depending somewhat on x-ray energies. We discuss these characteristics, taking into account the figure errors of reflectors and their optical alignment in the telescope assembly. This hard-x-ray telescope is unanimously afforded in the International Focusing Optics Collaboration for muCrab Sensitivity balloon experiment.

SELECTION OF CITATIONS
SEARCH DETAIL