Clin Transplant ; 38(7): e15408, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39044662

ABSTRACT

BACKGROUND: Pretransplant infection screening (IS) of potential organ recipients is essential to optimal outcome of solid organ transplantation (SOT). METHODS: A pre-post study was performed during 2020-2023 to investigate the impact of the STREAM (Solid organ TRansplant stEwArdship and Multidisciplinary approach) intervention to improve IS in SOT. The intervention, performed in 2022, included the implementation of IS through educational meetings, local guidelines, and the availability of a digital screening tool. The objective of the study was the assessment of IS completion, including a list of 17 laboratory tests and the investigation of vaccination status. The reduction of unnecessary tests was also analyzed. The test of proportions and a multilevel multivariate Poisson regression model were used to compare IS completion before and after STREAM. infectious diseases (ID) consultation and urgent evaluation were investigated as predictors of IS completion. RESULTS: A total of 171 patients were enrolled, including liver (44%), heart (32%), and kidney (24%) transplant candidates. Mean age was 56 ± 11 years, and most patients (77%) were males. Ninety-five (56%) patients were included before the intervention and 76 (44%) after STREAM. IS completion increased after STREAM (IRR 1.41, p < 0.001) with significant improvement recorded for seven (39%) IS items. Unnecessary tests decreased by 43% after the intervention. ID consultation (IRR 1.13, p = 0.02) and urgent evaluation (p = 0.68, p < 0.001) were predictors of IS improvement. CONCLUSIONS: STREAM was successful in improving IS completion. Further research is needed to investigate the impact of this intervention on posttransplant infections.


Subject(s)
Organ Transplantation , Humans , Male , Female , Middle Aged , Organ Transplantation/adverse effects , Follow-Up Studies , Prognosis , Mass Screening/methods , Infections/diagnosis , Infections/etiology , Transplant Recipients/statistics & numerical data , Postoperative Complications/prevention & control , Postoperative Complications/diagnosis , Risk Factors , Aged , Communicable Diseases/diagnosis , Communicable Diseases/etiology , Preoperative Care , Adult
2.
World J Surg ; 48(7): 1771-1782, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38686961

ABSTRACT

BACKGROUND: The benefits and harms associated with femoral artery cannulation over other sites of arterial cannulation for surgical repair of acute Stanford type A aortic dissection (TAAD) are not conclusively established. METHODS: We evaluated the outcomes after surgery for TAAD using femoral artery cannulation, supra-aortic arterial cannulation (i.e., innominate/subclavian/axillary artery cannulation), and direct aortic cannulation. RESULTS: 3751 (96.1%) patients were eligible for this analysis. In-hospital mortality using supra-aortic arterial cannulation was comparable to femoral artery cannulation (17.8% vs. 18.4%; adjusted OR 0.846, 95% CI 0.799-1.202). This finding was confirmed in 1028 propensity score-matched pairs of patients with supra-aortic arterial cannulation or femoral artery cannulation (17.5% vs. 17.0%, p = 0.770). In-hospital mortality after direct aortic cannulation was lower compared to femoral artery cannulation (14.0% vs. 18.4%, adjusted OR 0.703, 95% CI 0.529-0.934). Among 583 propensity score-matched pairs of patients, direct aortic cannulation was associated with lower rates of in-hospital mortality (13.4% vs. 19.6%, p = 0.004) compared to femoral artery cannulation. Switching of the primary site of arterial cannulation was associated with increased rate of in-hospital mortality (36.5% vs. 17.0%; adjusted OR 2.730, 95% CI 1.564-4.765). Ten-year mortality was similar in the study cohorts. CONCLUSIONS: In this study, the outcomes of surgery for TAAD using femoral arterial cannulation were comparable to those using supra-aortic arterial cannulation. However, femoral arterial cannulation was associated with higher in-hospital mortality than direct aortic cannulation. TRIAL REGISTRATION: ClinicalTrials.gov registration code: NCT04831073.


Subject(s)
Aortic Dissection , Femoral Artery , Hospital Mortality , Aged , Female , Humans , Male , Middle Aged , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/mortality , Aortic Dissection/surgery , Aortic Dissection/mortality , Catheterization/methods , Catheterization, Peripheral/methods , Femoral Artery/surgery , Propensity Score , Retrospective Studies , Treatment Outcome
3.
Ann Surg ; 278(4): e885-e892, 2023 10 01.
Article in English | MEDLINE | ID: mdl-36912033

ABSTRACT

OBJECTIVE: The aim of this study was to evaluate the outcomes of different surgical strategies for acute Stanford type A aortic dissection (TAAD). SUMMARY BACKGROUND DATA: The optimal extent of aortic resection during surgery for acute TAAD is controversial. METHODS: This is a multicenter, retrospective cohort study of patients who underwent surgery for acute TAAD at 18 European hospitals. RESULTS: Out of 3902 consecutive patients, 689 (17.7%) died during the index hospitalization. Among 2855 patients who survived 3 months after surgery, 10-year observed survival was 65.3%, while country-adjusted, age-adjusted, and sex-adjusted expected survival was 81.3%, yielding a relative survival of 80.4%. Among 558 propensity score-matched pairs, total aortic arch replacement increased the risk of in-hospital (21.0% vs. 14.9%, P =0.008) and 10-year mortality (47.1% vs. 40.1%, P =0.001), without decreasing the incidence of distal aortic reoperation (10-year: 8.9% vs. 7.4%, P =0.690) compared with ascending aortic replacement. Among 933 propensity score-matched pairs, in-hospital mortality (18.5% vs. 18.0%, P =0.765), late mortality (at 10-year: 44.6% vs. 41.9%, P =0.824), and cumulative incidence of proximal aortic reoperation (at 10-year: 4.4% vs. 5.9%, P =0.190) after aortic root replacement was comparable to supracoronary aortic replacement. CONCLUSIONS: Replacement of the aortic root and aortic arch did not decrease the risk of aortic reoperation in patients with TAAD and should be performed only in the presence of local aortic injury or aneurysm. The relative survival of TAAD patients is poor and suggests that the causes underlying aortic dissection may also impact late mortality despite surgical repair of the dissected aorta.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Aneurysm , Aortic Dissection , Blood Vessel Prosthesis Implantation , Humans , Aortic Aneurysm/surgery , Retrospective Studies , Treatment Outcome , Aortic Dissection/surgery , Reoperation , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation/adverse effects
5.
Transpl Int ; 36: 11675, 2023.
Article in English | MEDLINE | ID: mdl-37727385

ABSTRACT

Despite the withdrawal of the HeartWare Ventricular Assist Device (HVAD), hundreds of patients are still supported with this continuous-flow pump, and the long-term management of these patients is still under debate. This study aims to analyse 5 years survival and freedom from major adverse events in patients supported by HVAD and HeartMate3 (HM3). From 2010 to 2022, the MIRAMACS Italian Registry enrolled all-comer patients receiving a LVAD support at seven Cardiac Surgery Centres. Out of 447 LVAD implantation, 214 (47.9%) received HM3 and 233 (52.1%) received HVAD. Cox-regression analysis adjusted for major confounders showed an increased risk for mortality (HR 1.5 [1.2-1.9]; p = 0.031), for both ischemic stroke (HR 2.08 [1.06-4.08]; p = 0.033) and haemorrhagic stroke (HR 2.6 [1.3-4.9]; p = 0.005), and for pump thrombosis (HR 25.7 [3.5-188.9]; p < 0.001) in HVAD patients. The propensity-score matching analysis (130 pairs of HVAD vs. HM3) confirmed a significantly lower 5 years survival (81.25% vs. 64.1%; p 0.02), freedom from haemorrhagic stroke (90.5% vs. 70.1%; p < 0.001) and from pump thrombosis (98.5% vs. 74.7%; p < 0.001) in HVAD cohort. Although similar perioperative outcome, patients implanted with HVAD developed a higher risk for mortality, haemorrhagic stroke and thrombosis during 5 years of follow-up compared to HM3 patients.


Subject(s)
Heart-Assist Devices , Hemorrhagic Stroke , Humans , Registries , Propensity Score , Magnetic Phenomena
6.
World J Surg ; 47(11): 2899-2908, 2023 11.
Article in English | MEDLINE | ID: mdl-37432422

ABSTRACT

AIMS: In this study we evaluated the impact of direct aortic cannulation versus innominate/subclavian/axillary artery cannulation on the outcome after surgery for type A aortic dissection. METHODS: The outcomes of patients included in a multicenter European registry (ERTAAD) who underwent surgery for acute type A aortic dissection with direct aortic cannulation versus those with innominate/subclavian/axillary artery cannulation, i.e. supra-aortic arterial cannulation, were compared using propensity score matched analysis. RESULTS: Out of 3902 consecutive patients included in the registry, 2478 (63.5%) patients were eligible for this analysis. Direct aortic cannulation was performed in 627 (25.3%) patients, while supra-aortic arterial cannulation in 1851 (74.7%) patients. Propensity score matching yielded 614 pairs of patients. Among them, patients who underwent surgery for TAAD with direct aortic cannulation had significantly decreased in-hospital mortality (12.7% vs. 18.1%, p = 0.009) compared to those who had supra-aortic arterial cannulation. Furthermore, direct aortic cannulation was associated with decreased postoperative rates of paraparesis/paraplegia (2.0 vs. 6.0%, p < 0.0001), mesenteric ischemia (1.8 vs. 5.1%, p = 0.002), sepsis (7.0 vs. 14.2%, p < 0.0001), heart failure (11.2 vs. 15.2%, p = 0.043), and major lower limb amputation (0 vs. 1.0%, p = 0.031). Direct aortic cannulation showed a trend toward decreased risk of postoperative dialysis (10.1 vs. 13.7%, p = 0.051). CONCLUSIONS: This multicenter cohort study showed that direct aortic cannulation compared to supra-aortic arterial cannulation is associated with a significant reduction of the risk of in-hospital mortality after surgery for acute type A aortic dissection. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT04831073.


Subject(s)
Aortic Dissection , Catheterization , Humans , Cohort Studies , Treatment Outcome , Aorta , Aortic Dissection/surgery , Retrospective Studies
7.
Thorac Cardiovasc Surg ; 71(6): 462-468, 2023 09.
Article in English | MEDLINE | ID: mdl-36736367

ABSTRACT

OBJECTIVES: The aim of the present study was to evaluate the results of isolated coronary artery bypass grafting (CABG) with or without revascularization of the occluded right coronary artery (RCA). METHODS: Patients undergoing isolated CABG were included in a prospective European multicenter registry. Outcomes were adjusted for imbalance in preoperative variables with propensity score matching analysis. Late outcomes were evaluated with Kaplan-Meier's method and competing risk analysis. RESULTS: Out of 2,948 included in this registry, 724 patients had a total occlusion of the RCA and were the subjects of this analysis. Occluded RCA was not revascularized in 251 (34.7%) patients with significant variability between centers. Among 245 propensity score-matched pairs, patients with and without revascularization of occluded RCA had similar early outcomes. The nonrevascularized RCA group had increased rates of 5-year all-cause mortality (17.7 vs. 11.7%, p = 0.039) compared with patients who had their RCA revascularized. The rates of myocardial infarction and repeat revascularization were only numerically increased but contributed to a significantly higher rate of MACCE (24.7 vs. 15.7%, p = 0.020) at 5 year among patients with nonrevascularized RCA. CONCLUSION: In this multicenter study, one-third of totally occluded RCAs was not revascularized during isolated CABG for multivessel coronary artery disease. Failure to revascularize an occluded RCA in these patients increased the risk of all-cause mortality and MACCEs at 5 years.


Subject(s)
Coronary Artery Disease , Percutaneous Coronary Intervention , Humans , Prospective Studies , Treatment Outcome , Coronary Artery Bypass , Coronary Artery Disease/surgery
8.
Int J Mol Sci ; 25(1)2023 Dec 24.
Article in English | MEDLINE | ID: mdl-38203459

ABSTRACT

Left ventricular assist devices (LVADs) represent the final treatment for patients with end-stage heart failure (HF) not eligible for transplantation. Although LVAD design has been further improved in the last decade, their use is associated with different complications. Specifically, inflammation, fibrosis, bleeding events, right ventricular failure, and aortic valve regurgitation may occur. In addition, reverse remodeling is associated with substantial cellular and molecular changes of the failing myocardium during LVAD support with positive effects on patients' health. All these processes also lead to the identification of biomarkers identifying LVAD patients as having an augmented risk of developing associated adverse events, thus highlighting the possibility of identifying new therapeutic targets. Additionally, it has been reported that LVAD complications could cause or exacerbate a state of malnutrition, suggesting that, with an adjustment in nutrition, the general health of these patients could be improved.


Subject(s)
Aortic Valve Insufficiency , Heart Failure , Heart-Assist Devices , Malnutrition , Humans , Heart-Assist Devices/adverse effects , Heart Failure/therapy , Inflammation
9.
Int J Mol Sci ; 24(21)2023 Oct 24.
Article in English | MEDLINE | ID: mdl-37958492

ABSTRACT

Aortic stenosis (AS) involves progressive valve obstruction and a remodeling response of the left ventriculum (LV) with systolic and diastolic dysfunction. The roles of interstitial fibrosis and myocardial steatosis in LV dysfunction in AS have not been completely characterized. We enrolled 31 patients (19 women and 12 men) with severe AS undergoing elective aortic valve replacement. The subjects were clinically evaluated, and transthoracic echocardiography was performed pre-surgery. LV septal biopsies were obtained to assess fibrosis and apoptosis and fat deposition in myocytes (perilipin 5 (PLIN5)), or in the form of adipocytes within the heart (perilipin 1 (PLIN1)), the presence of ceramides and myostatin were assessed via immunohistochemistry. After BMI adjustment, we found a positive association between fibrosis and apoptotic cardiomyocytes, as well as fibrosis and the area covered by PLIN5. Apoptosis and PLIN5 were also significantly interrelated. LV fibrosis increased with a higher medium gradient (MG) and peak gradient (PG). Ceramides and myostatin levels were higher in patients within the higher MG and PG tertiles. In the linear regression analysis, increased fibrosis correlated with increased apoptosis and myostatin, independent from confounding factors. After adjustment for age and BMI, we found a positive relationship between PLIN5 and E/A and a negative correlation between septal S', global longitudinal strain (GLS), and fibrosis. Myostatin was inversely correlated with GLS and ejection fraction. Fibrosis and myocardial steatosis altogether contribute to ventricular dysfunction in severe AS. The association of myostatin and fibrosis with systolic dysfunction, as well as between myocardial steatosis and diastolic dysfunction, highlights potential therapeutic targets.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Male , Humans , Female , Ventricular Function, Left , Ceramides , Myostatin , Aortic Valve Stenosis/surgery , Fibrosis , Aortic Valve/pathology , Stroke Volume
10.
Heart Lung Circ ; 32(3): 387-394, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36566143

ABSTRACT

AIM: The aim of this study was to assess the impact of surgeon experience and centre volume on early operative outcomes in patients undergoing off-pump coronary artery bypass (OPCAB) surgery. METHOD: Of 7,352 patients in the European Multicenter Study on Coronary Artery Bypass Grafting (E-CABG) registry, 1,549 underwent OPCAB and were included in the present analysis. Using adjusted regression analysis, we compared major early adverse events after procedures performed by experienced OPCAB surgeons (i.e., ≥20 cases per year; n=1,201) to those performed by non-OPCAB surgeons (n=348). Furthermore, the same end points were compared between procedures performed by OPCAB surgeons in high OPCAB volume centres (off-pump technique used in >50% of cases; n=894) and low OPCAB volume centres (n=307). RESULTS: In the experienced OPCAB surgeon group, we observed shorter procedure times (ß -43.858, 95% confidence interval [CI] -53.322 to -34.393; p<0.001), a lower rate of conversion to cardiopulmonary bypass (odds ratio [OR] 0.284, 95% CI 0.147-0.551; p<0.001), a lower rate of prolonged inotrope or vasoconstrictor use (OR 0.492, 95% CI 0.371-0.653; p<0.001), a lower rate of early postprocedural percutaneous coronary interventions (OR 0.335, 95% CI 0.169-0.663; p=0.002), and lower 30-day mortality (OR 0.423, 95% CI 0.194-0.924; p=0.031). In high OPCAB volume centres, we found a lower rate of prolonged inotrope use (OR 0.584, 95% CI 0.419-0.814; p=0.002), a lower rate of postprocedural acute kidney injury (OR 0.382, 95% CI 0.198-0.738; p=0.004), shorter duration of intensive care unit (ß -1.752, 95% CI -2.240 to -1.264; p<0.001) and hospital (ß -1.967; 95% CI -2.717 to -1.216; p<0.001) stays, and lower 30-day mortality (OR 0.316, 95% CI 0.114-0.881; p=0.028). CONCLUSIONS: Surgeon experience and centre volume may play an important role on the early outcomes after OPCAB surgery.


Subject(s)
Coronary Artery Bypass, Off-Pump , Surgeons , Humans , Coronary Artery Bypass, Off-Pump/adverse effects , Coronary Artery Bypass, Off-Pump/methods , Coronary Artery Bypass/adverse effects , Coronary Artery Bypass/methods , Time Factors , Registries , Treatment Outcome
11.
Medicina (Kaunas) ; 59(6)2023 May 31.
Article in English | MEDLINE | ID: mdl-37374264

ABSTRACT

Background and Objectives: To evaluate the early and long-term results of surgical treatment of isolated mitral native and prosthetic valve infective endocarditis. Materials and Methods: All patients undergoing mitral valve repair or replacement for infective endocarditis at our institution between January 2001 and December 2021 were included in the study. The preoperative and postoperative characteristics and mortality of patients were retrospectively reviewed. Results: A total of 130 patients, 85 males and 45 females, with a median age of 61 ± 14 years, underwent surgery for isolated mitral valve endocarditis during the study period. There were 111 (85%) native and 19 (15%) prosthetic valve endocarditis cases. Fifty-one (39%) patients died during the follow-up, and the overall mean patient survival time was 11.8 ± 0.9 years. The mean survival time was better in patients with mitral native valve endocarditis compared to patients with prosthetic valve endocarditis (12.3 ± 0.9 years vs. 8 ± 1.4 years; p = 0.1), but the difference was not statistically significant. Patients who underwent mitral valve repair had a better survival rate compared to patients who had mitral valve replacement (14.8 ± 1.6 vs. 11.3 ± 1 years; p = 0.06); however, the difference was not statistically significant. Patients who underwent mitral valve replacement with a mechanical prosthesis had a significantly better survival rate compared to patients who received a biological prosthesis (15.6 ± 1.6 vs. 8.2 ± 0.8 years; p < 0.001). Patients aged ≤60 years had significantly better survival compared to patients aged >60 years (17.1 ± 1.1 vs. 8.2 ± 0.9; p < 0.001). Multivariate analysis showed that the patient's age >60 years at the time of surgery was an independent risk factor for mortality, while mitral valve repair was a protective factor. Eight (7%) patients required reintervention. Freedom from reintervention was significantly higher in patients with mitral native valve endocarditis compared to patients with prosthetic valve endocarditis (19.3 ± 0.5 vs. 11.5 ± 1.7 years; p = 0.04). Conclusions: Surgery for mitral valve endocarditis is associated with considerable morbidity and mortality. The patient's age at the time of surgery represents an independent risk factor for mortality. Mitral valve repair should be the preferred choice whenever possible in suitable patients affected by infective endocarditis.


Subject(s)
Endocarditis, Bacterial , Endocarditis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Male , Female , Humans , Middle Aged , Aged , Endocarditis, Bacterial/surgery , Mitral Valve/surgery , Retrospective Studies , Treatment Outcome , Heart Valve Prosthesis/adverse effects , Endocarditis/surgery
13.
Rev Cardiovasc Med ; 23(7): 228, 2022 Jul.
Article in English | MEDLINE | ID: mdl-39076901

ABSTRACT

Background and Aim of the Study: In patients with acute type A aortic dissection (A-AAD) whether initial repair should include also aortic arch replacement is still debated. We aimed to assess if extensive aortic repair prevents from reoperations patients with A-AAD. Methods: Outcomes after distal reoperation following repair of A-AAD (n = 285; 1977 to 2018) were analysed in 22 of 226 who underwent ascending aorta/hemiarch replacement (Group 1 R ) and 7 of 59 who had ascending aorta/arch replacement (Group 2 R ). Results: Distal reoperation was more common in Group 1 R (n = 22) than in Group 2 R (n = 0) (p < 0.001) while thoracic endovascular stenting was more frequent in Group 2 R (7 vs 3, p < 0.001). Indications for reoperation were pseudoaneurysm at distal anastomosis (n = 4, 18%) and progression of aortic dissection (n = 18, 82%) in Group 1 R . Indication for thoracic endovascular stenting was progressive aortic dissection in 3 patients of Group 1 R and in 6 of Group 2 R . Second reoperation was required in 2 patients from Group 1 R (2%) during a mean follow-up of 5 years. Median follow-up was 4 years in Group 1 R and 7 years in Group 2 R (p = 0.36). Hospital mortality was 14% in Group 1 R and 0% in Group 2 R (p = 0.3). Actuarial survival is 68 ± 10%, and 62 ± 11% for Group 1 R and 100% for Group 2 R at 5 and 10 years (p = 0.076). Conclusions: Distal reoperations after A-AAD repair have an acceptable mortality. An extensive initial repair has lower rate of reoperation and better mid-term survival and should be indicated especially for young patients in experienced centers.

14.
Ann Vasc Surg ; 78: 132-140, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34175420

ABSTRACT

BACKGROUND: To report the early outcomes of cone beam computed tomography (CBCT) using last generation 3D C-arm in patients undergone advanced endovascular aortic aneurysm repair (AdEVAR) and to identify risk factors that may predict any un-planned procedures. METHODS: Patients undergone AdEVAR between December 2017 and December 2018 were enrolled. Final CBCT was performed in all patients after digital subtraction angiography. Primary end points were the incidence of any positive findings and the following unplanned procedures intended as any endovascular manoeuvre performed to fix such technical defect. The secondary endpoints were comparison of outcomes between patients with positive findings undergone unplanned procedure (Group A) versus patients without findings (Group B). RESULTS: 132 patients underwent endovascular treatment for aortic aneurysm. Of these, 22 (33%) fenestrated-branched endovascular aneurysm repairs (F-BEVAR), 21 (29%) EVAR with iliac branch devices, 19 (26%) abdominal and 10 (14%) thoracic EVAR were included in the study. Unplanned procedures after CBCT were necessary in 22 patients (31%). Patients in both groups were similar excepted for BMI >25 kg/m2 (55% vs. 26%), hostile iliac anatomy (64% vs. 32%) and previous aortic treatment (73% vs. 32%) (P < 0.05). The odds ratios for unplanned procedure in case of previous aortic treatment was 6.76 (95% CI, 1.97-23.16; P = 0.002). CONCLUSION: The use of CBCT, especially in challenging scenarios, can reveal technical defects and may potentially limit the need for late reintervention. Patients undergone previous aortic surgery should be carefully evaluated and routine CBCT should be performed.


Subject(s)
Aortic Aneurysm/surgery , Cone-Beam Computed Tomography , Endovascular Procedures/methods , Surgery, Computer-Assisted , Aged , Aged, 80 and over , Angiography, Digital Subtraction , Aorta/diagnostic imaging , Aortic Aneurysm/diagnostic imaging , Equipment Design , Female , Humans , Male , Prospective Studies , Plastic Surgery Procedures , Risk Factors
15.
Heart Lung Circ ; 31(2): 263-271, 2022 Feb.
Article in English | MEDLINE | ID: mdl-34330630

ABSTRACT

BACKGROUND: Postoperative bleeding after cardiac surgery is associated with increased morbidity and mortality. We tested the hypothesis that patients with a preoperatively estimated high risk of severe perioperative bleeding may have impaired early outcome after on-pump versus off-pump coronary artery bypass grafting (CABG). METHOD: Data from 7,352 consecutive patients who underwent isolated CABG from January 2015 to May 2017 were included in the multicentre European Coronary Artery Bypass Grafting registry. The postoperative bleeding risk was estimated using the WILL-BLEED risk score. Of all included patients, 3,548 had an increased risk of severe perioperative bleeding (defined as a WILL-BLEED score ≥4) and were the subjects of this analysis. We compared the early outcomes between patients who underwent on-pump or off-pump CABG using a multivariate mixed model for risk-adjusted analysis. RESULTS: Off-pump surgery was performed in 721 patients (20.3%). On-pump patients received more packed red blood cell units (on-pump: 1.41 [95% confidence interval {CI} 0.99-1.86]; off-pump: 0.86 [95% CI 0.64-1.08]; p<0.001), had a longer stay in the intensive care unit (on-pump: 4.4 [95% CI 3.6-8.1] days; off-pump: 3.2 [95% CI 2.0-4.4] days; p=0.049), and a higher rate of postoperative atrial fibrillation (on-pump: 46.5% [95% CI 34.9-58.1]; off-pump: 31.3% [95% CI 21.7-40.9]; p=0.025). Furthermore, on-pump patients showed a trend towards a higher rate of postoperative stroke (on-pump: 2.4% [95% CI 0.9-4.1]; off-pump: 1.1 [95% CI 0.2-2.7]; p=0.094). CONCLUSION: Our data suggest that in patients with an increased risk of bleeding, the use of cardiopulmonary bypass is associated with higher morbidity. These patients may benefit from off-pump surgery if complete revascularisation can be ensured.


Subject(s)
Atrial Fibrillation , Coronary Artery Bypass, Off-Pump , Cardiopulmonary Bypass , Coronary Artery Bypass/adverse effects , Coronary Artery Bypass, Off-Pump/adverse effects , Humans , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Retrospective Studies , Treatment Outcome
16.
Eur J Clin Invest ; 51(12): e13662, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34347897

ABSTRACT

BACKGROUND: Heart failure (HF) is a complex syndrome affecting the whole body, kidneys included. The left ventricular assist device (LVAD) is a valid option for patients with very severe HF. Focusing on renal function, LVAD implantation could theoretically reverse the detrimental effects of HF syndrome on kidneys. However, implanting an LVAD is a high-risk surgical procedure, and LVAD patients have higher risk of bleeding, device thrombosis, strokes, renal impairment, multi-organ failure and infections. Furthermore, an LVAD has its own particular effects on the renal system. METHODS: In this review, we provide a comprehensive overview of the complex interaction between LVAD and the kidneys from the pathophysiological and clinical perspectives. An analysis of the different effects of pulsatile-flow and continuous-flow LVAD is provided. RESULTS: Despite their limitations, creatinine-based estimated glomerular filtration rate (eGFR) formulas help to stratify patients by their post-LVAD placement prognosis. Poor basal renal function, the onset of acute kidney injury or the need for renal replacement therapy after LVAD implantation negatively influences a patient's prognosis. LVAD can also prompt an improvement in renal function, however, with some counterintuitive effects on a patient's prognosis. CONCLUSION: It is still hard to say whether different trends in eGFR depend on different renal conditions before LVAD placement, on a patient's better overall status or on a particular patient management strategy before and/or after the device's implantation. Steps should be taken to solve this question because finding the best candidates for LVAD implantation is of paramount importance to ensure the best outcomes.


Subject(s)
Cardio-Renal Syndrome/metabolism , Heart Failure/therapy , Heart-Assist Devices , Renal Insufficiency, Chronic/metabolism , Acute Kidney Injury/complications , Acute Kidney Injury/metabolism , Acute Kidney Injury/physiopathology , Cardio-Renal Syndrome/physiopathology , Creatinine/metabolism , Glomerular Filtration Rate , Heart Failure/complications , Heart Failure/metabolism , Heart Failure/physiopathology , Humans , Prognosis , Renal Insufficiency, Chronic/complications , Renal Insufficiency, Chronic/physiopathology , Renal Insufficiency, Chronic/therapy , Renal Replacement Therapy , Treatment Outcome
17.
Ann Vasc Surg ; 72: 627-636, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33197539

ABSTRACT

BACKGROUND: Carotid endarterectomy (CEA) has a wide range of approaches based on personal expertise and preference. We evaluated our outcome with CEA with modified eversion technique (meCEA) under local anesthesia and whether the surgeon's experience could influence it. METHODS: at our Institution, 837 patients underwent CEA across 8 years. Although the surgical technique was standardized, 2 groups were considered further: meCEA performed by a single Senior Operator (Group A) and meCEA performed by 4 young Consultants (Group B). RESULTS: A selective shunting policy was needed in 5.1%, together with general anesthesia. Overall operative time was 63.9 ± 15.1 minutes (61.4 ± 12.5 and 66 ± 16.9 minutes in Group A and Group B respectively; P < 0.001) and cross-clamp time 19.3 ± 2.9 minutes (19.0 ± 3.2 vs. 19.5 ± 2.8, P = 0.009). At 30 days, 0.7% TIA and 0.8% strokes were recorded. No differences (p = N.S.) between the 2 study groups in terms of postoperative neurological complications, with postoperative ipsilateral strokes always < 1%. At a median imaging follow-up of 22.5 months, the overall percentage of restenosis was 3.7%, with no difference between the 2 groups (P = 0.954). Twenty-two patients (2.6%) underwent reintervention for significant restenosis, and none of them had an ipsilateral stroke or TIA. Freedom from reintervention for restenosis at 24 months was 97.9% in Group A and 95.9% in Group B, with no between-group difference (P = 0.14). At the median survival follow-up of 37 months, the overall survival rate at 24 months was 97.9%in Group A, and 97.9% in Group B, with no between-group difference (P = 0.070). CONCLUSIONS: In our experience, CEA with a modified technique is safe and achieves comparable outcomes to those of other established techniques. The reported short cross-clamp time, also in less experienced hands, is an additional strength.


Subject(s)
Carotid Stenosis/surgery , Endarterectomy, Carotid , Aged , Aged, 80 and over , Anesthesia, Local , Carotid Stenosis/complications , Carotid Stenosis/diagnostic imaging , Clinical Competence , Endarterectomy, Carotid/adverse effects , Female , Humans , Ischemic Attack, Transient/etiology , Italy , Male , Recurrence , Registries , Retrospective Studies , Risk Assessment , Risk Factors , Stroke/etiology , Surgeons , Time Factors , Treatment Outcome
19.
J Cardiothorac Vasc Anesth ; 34(8): 2091-2099, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32362544

ABSTRACT

OBJECTIVE: To evaluate current results of surgical aortic valve replacement (SAVR) ± coronary artery bypass grafting surgery. DESIGN: Independent, multicenter, prospective registry. SETTING: Tertiary university hospitals. PARTICIPANTS: The study comprised 1,192 consecutive patients, stratified as low-, intermediate-, and high-risk according to EuroSCORE II (<4, 4-9, >9, respectively). INTERVENTIONS: SAVR ± coronary artery bypass grafting surgery. MEASUREMENTS AND MAIN RESULTS: Thirty-day mortality and major morbidity, 2-year actuarial survival and freedom from stroke, and independent predictors of mortality in each risk category were assessed. These data were considered in light of published randomized controlled trials. Thirty-day mortality was 1.0%, 3.0% and 2.1% in the low-, intermediate-, and high-risk patients, with a 2-year actuarial survival of 98.6%, 93.8%, and 94.0%, respectively. Preoperative atrial fibrillation (odds ratio [OR] 8.3), minithoracotomy access (OR 5.8), postoperative dialysis (OR 3.4), type V acute myocardial infarction (OR 20.4), and moderate aortic regurgitation (OR 28.8) predicted 30-day mortality in the low-risk group. Preoperative dialysis (OR 18.3), critical state (OR 36.7), postoperative transfusions of plasma (OR 1.9 per unit transfused), and de-novo dialysis (OR 6.2) predicted 30-day mortality in the intermediate-risk group. Prior cardiac surgery (OR 18.1), postoperative extracorporeal membrane oxygenation (OR 9.8), and gastrointestinal complications (OR 17.2) predicted 30-day mortality in the high-risk group. Although baseline differences existed, low-risk patients demonstrated low 30-day mortality and 30-day to 12-month stroke in light of the PARTNER 3 and EVOLUT Low Risk trial results. Intermediate-risk patients demonstrated low 30-day to 2-year mortality, when the PARTNER 2 trial was considered, and low 30-day to 2-year stroke, when the PARTNER 2 and SURTAVI trials were considered. High-risk patients showed low 30-day to 2-year mortality in light of the results of the PARTNER 1 and CoreValve US trials. CONCLUSIONS: SAVR is still a safe and effective surgery for aortic stenosis regardless of risk category.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Humans , Postoperative Complications , Registries , Risk Assessment , Risk Factors , Treatment Outcome
20.
J Card Surg ; 35(9): 2429-2431, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32652800

ABSTRACT

According to latest guidelines, percutaneous mitral commissurotomy (PMC) represents the first-line treatment for symptomatic severe mitral valve stenosis with favorable morphology. We report successful surgical treatment of a potential life-threatening complication occurred during PMC. Heart-team discussion and closed collaboration with centers are crucial for decision-making and cardiac surgery onsite should be ensured for high-risk procedures.


Subject(s)
Cardiac Surgical Procedures , Mitral Valve Stenosis , Catheterization/adverse effects , Catheters , Heart Atria/diagnostic imaging , Heart Atria/surgery , Humans , Mitral Valve Stenosis/diagnostic imaging , Mitral Valve Stenosis/etiology , Mitral Valve Stenosis/surgery