Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 73
Filter
1.
Eur Radiol ; 2024 Jan 16.
Article in English | MEDLINE | ID: mdl-38227202

ABSTRACT

OBJECTIVES: To perform a survey among members of the European Society of Breast Imaging (EUSOBI) regarding the use of contrast-enhanced mammography (CEM). METHODS: A panel of nine board-certified radiologists developed a 29-item online questionnaire, distributed to all EUSOBI members (inside and outside Europe) from January 25 to March 10, 2023. CEM implementation, examination protocols, reporting strategies, and current and future CEM indications were investigated. Replies were exploratively analyzed with descriptive and non-parametric statistics. RESULTS: Among 434 respondents (74.9% from Europe), 50% (217/434) declared to use CEM, 155/217 (71.4%) seeing less than 200 CEMs per year. CEM use was associated with academic settings and high breast imaging workload (p < 0.001). The lack of CEM adoption was most commonly due to the perceived absence of a clinical need (65.0%) and the lack of resources to acquire CEM-capable systems (37.3%). CEM protocols varied widely, but most respondents (61.3%) had already adopted the 2022 ACR CEM BI-RADS® lexicon. CEM use in patients with contraindications to MRI was the most common current indication (80.6%), followed by preoperative staging (68.7%). Patients with MRI contraindications also represented the most commonly foreseen CEM indication (88.0%), followed by the work-up of inconclusive findings at non-contrast examinations (61.5%) and supplemental imaging in dense breasts (53.0%). Respondents declaring CEM use and higher CEM experience gave significantly more current (p = 0.004) and future indications (p < 0.001). CONCLUSIONS: Despite a trend towards academic high-workload settings and its prevalent use in patients with MRI contraindications, CEM use and progressive experience were associated with increased confidence in the technique. CLINICAL RELEVANCE STATEMENT: In this first survey on contrast-enhanced mammography (CEM) use and perspectives among the European Society of Breast Imaging (EUSOBI) members, the perceived absence of a clinical need chiefly drove the 50% CEM adoption rate. CEM adoption and progressive experience were associated with more extended current and future indications. KEY POINTS: • Among the 434 members of the European Society of Breast Imaging who completed this survey, 50% declared to use contrast-enhanced mammography in clinical practice. • Due to the perceived absence of a clinical need, contrast-enhanced mammography (CEM) is still prevalently used as a replacement for MRI in patients with MRI contraindications. • The number of current and future CEM indications marked by respondents was associated with their degree of CEM experience.

2.
Eur Radiol ; 2024 Apr 19.
Article in English | MEDLINE | ID: mdl-38639912

ABSTRACT

OBJECTIVES: Supplemental MRI screening improves early breast cancer detection and reduces interval cancers in women with extremely dense breasts in a cost-effective way. Recently, the European Society of Breast Imaging recommended offering MRI screening to women with extremely dense breasts, but the debate on whether to implement it in breast cancer screening programs is ongoing. Insight into the participant experience and willingness to re-attend is important for this discussion. METHODS: We calculated the re-attendance rates of the second and third MRI screening rounds of the DENSE trial. Moreover, we calculated age-adjusted odds ratios (ORs) to study the association between characteristics and re-attendance. Women who discontinued MRI screening were asked to provide one or more reasons for this. RESULTS: The re-attendance rates were 81.3% (3458/4252) and 85.2% (2693/3160) in the second and third MRI screening round, respectively. A high age (> 65 years), a very low BMI, lower education, not being employed, smoking, and no alcohol consumption were correlated with lower re-attendance rates. Moderate or high levels of pain, discomfort, or anxiety experienced during the previous MRI screening round were correlated with lower re-attendance rates. Finally, a plurality of women mentioned an examination-related inconvenience as a reason to discontinue screening (39.1% and 34.8% in the second and third screening round, respectively). CONCLUSIONS: The willingness of women with dense breasts to re-attend an ongoing MRI screening study is high. However, emphasis should be placed on improving the MRI experience to increase the re-attendance rate if widespread supplemental MRI screening is implemented. CLINICAL RELEVANCE STATEMENT: For many women, MRI is an acceptable screening method, as re-attendance rates were high - even for screening in a clinical trial setting. To further enhance the (re-)attendance rate, one possible approach could be improving the overall MRI experience. KEY POINTS: • The willingness to re-attend in an ongoing MRI screening study is high. • Pain, discomfort, and anxiety in the previous MRI screening round were related to lower re-attendance rates. • Emphasis should be placed on improving MRI experience to increase the re-attendance rate in supplemental MRI screening.

3.
Breast Cancer Res Treat ; 201(1): 67-75, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37322358

ABSTRACT

PURPOSE: In breast conserving surgery, accurate lesion localization is essential for obtaining adequate surgical margins. Preoperative wire localization (WL) and radioactive seed localization (RSL) are widely accepted methods to guide surgical excision of nonpalpable breast lesions but are limited by logistical challenges, migration issues, and legislative complexities. Radiofrequency identification (RFID) technology may offer a viable alternative. The purpose of this study was to evaluate the feasibility, clinical acceptability, and safety of RFID surgical guidance for localization of nonpalpable breast cancer. METHODS: In a prospective multicentre cohort study, the first 100 RFID localization procedures were included. The primary outcome was the percentage of clear resection margins and re-excision rate. Secondary outcomes included procedure details, user experience, learningcurve, and adverse events. RESULTS: Between April 2019 and May 2021, 100 women underwent RFID guided breast conserving surgery. Clear resection margins were obtained in 89 out of 96 included patients (92.7%), re-excision was indicated in three patients (3.1%). Radiologists reported difficulties with the placement of the RFID tag, partially related to the relatively large needle-applicator (12-gauge). This led to the premature termination of the study in the hospital using RSL as regular care. The radiologist experience was improved after a manufacturer modification of the needle-applicator. Surgical localization involved a low learning curve. Adverse events (n = 33) included dislocation of the marker during insertion (8%) and hematomas (9%). The majority of adverse events (85%) occurred using the first-generation needle-applicator. CONCLUSION: RFID technology is a potential alternative for non-radioactive and non-wire localization of nonpalpable breast lesions.


Subject(s)
Breast Neoplasms , Female , Humans , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/surgery , Prospective Studies , Margins of Excision , Cohort Studies , Feasibility Studies , Mastectomy, Segmental/methods
4.
Radiology ; 308(2): e222841, 2023 08.
Article in English | MEDLINE | ID: mdl-37552061

ABSTRACT

Background Automated identification of quantitative breast parenchymal enhancement features on dynamic contrast-enhanced (DCE) MRI scans could provide added value in assessment of breast cancer risk in women with extremely dense breasts. Purpose To automatically identify quantitative properties of the breast parenchyma on baseline DCE MRI scans and assess their association with breast cancer occurrence in women with extremely dense breasts. Materials and Methods This study represents a secondary analysis of the Dense Tissue and Early Breast Neoplasm Screening trial. MRI was performed in eight hospitals between December 2011 and January 2016. After segmentation of fibroglandular tissue, quantitative features (including volumetric density, volumetric morphology, and enhancement characteristics) of the parenchyma were extracted from baseline MRI scans. Principal component analysis was used to identify parenchymal measures with the greatest variance. Multivariable Cox proportional hazards regression was applied to assess the association between breast cancer occurrence and quantitative parenchymal features, followed by stratification of significant features into tertiles. Results A total of 4553 women (mean age, 55.7 years ± 6 [SD]) with extremely dense breasts were included; of these women, 122 (3%) were diagnosed with breast cancer. Five principal components representing 96% of the variance were identified, and the component explaining the greatest independent variance (42%) consisted of MRI features relating to volume of enhancing parenchyma. Multivariable analysis showed that volume of enhancing parenchyma was associated with breast cancer occurrence (hazard ratio [HR], 1.09; 95% CI: 1.01, 1.18; P = .02). Additionally, women in the high tertile of volume of enhancing parenchyma showed a breast cancer occurrence twice that of women in the low tertile (HR, 2.09; 95% CI: 1.25, 3.61; P = .005). Conclusion In women with extremely dense breasts, a high volume of enhancing parenchyma on baseline DCE MRI scans was associated with increased occurrence of breast cancer as compared with a low volume of enhancing parenchyma. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Grimm in this issue.


Subject(s)
Breast Neoplasms , Female , Humans , Middle Aged , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/epidemiology , Breast Density , Mammography/methods , Breast/diagnostic imaging , Magnetic Resonance Imaging/methods
5.
Radiology ; 307(4): e221922, 2023 05.
Article in English | MEDLINE | ID: mdl-36975820

ABSTRACT

Background Several single-center studies found that high contralateral parenchymal enhancement (CPE) at breast MRI was associated with improved long-term survival in patients with estrogen receptor (ER)-positive and human epidermal growth factor receptor 2 (HER2)-negative breast cancer. Due to varying sample sizes, population characteristics, and follow-up times, consensus of the association is currently lacking. Purpose To confirm whether CPE is associated with long-term survival in a large multicenter retrospective cohort, and to investigate if CPE is associated with endocrine therapy effectiveness. Materials and Methods This multicenter observational cohort included women with unilateral ER-positive HER2-negative breast cancer (tumor size ≤50 mm and ≤three positive lymph nodes) who underwent MRI from January 2005 to December 2010. Overall survival (OS), recurrence-free survival (RFS), and distant RFS (DRFS) were assessed. Kaplan-Meier analysis was performed to investigate differences in absolute risk after 10 years, stratified according to CPE tertile. Multivariable Cox proportional hazards regression analysis was performed to investigate whether CPE was associated with prognosis and endocrine therapy effectiveness. Results Overall, 1432 women (median age, 54 years [IQR, 47-63 years]) were included from 10 centers. Differences in absolute OS after 10 years were stratified according to CPE tertile as follows: 88.5% (95% CI: 88.1, 89.1) in tertile 1, 85.8% (95% CI: 85.2, 86.3) in tertile 2, and 85.9% (95% CI: 85.4, 86.4) in tertile 3. CPE was independently associated with OS, with a hazard ratio (HR) of 1.17 (95% CI: 1.0, 1.36; P = .047), but was not associated with RFS (HR, 1.11; P = .16) or DRFS (HR, 1.11; P = .19). The effect of endocrine therapy on survival could not be accurately assessed; therefore, the association between endocrine therapy efficacy and CPE could not reliably be estimated. Conclusion High contralateral parenchymal enhancement was associated with a marginally decreased overall survival in patients with estrogen receptor-positive and human epidermal growth factor receptor 2-negative breast cancer, but was not associated with recurrence-free survival (RFS) or distant RFS. Published under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Honda and Iima in this issue.


Subject(s)
Breast Neoplasms , Triple Negative Breast Neoplasms , Humans , Female , Middle Aged , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/drug therapy , Breast Neoplasms/metabolism , Receptors, Estrogen , Retrospective Studies , Triple Negative Breast Neoplasms/pathology , Breast/diagnostic imaging , Breast/metabolism , Prognosis , Receptor, ErbB-2/metabolism , Magnetic Resonance Imaging/methods , Disease-Free Survival , Neoplasm Recurrence, Local/pathology
6.
Eur Radiol ; 33(11): 8103-8111, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37481690

ABSTRACT

OBJECTIVES: Quality assurance (QA) of image interpretation plays a key role in screening and diagnostic mammography, maintaining minimum standards and supporting continuous improvement in interpreting images. However, the QA structure across Europe shows considerable variation. The European Society of Breast Imaging (EUSOBI) conducted a survey among the members to collect information on radiologists' preferences regarding QA measures in mammography. MATERIALS AND METHODS: An anonymous online survey consisting of 25 questions was distributed to all EUSOBI members and national breast radiology bodies in Europe. The questions were designed to collect demographic characteristics, information on responders' mammography workload and data about QA measures currently used in their country. Data was analysed using descriptive statistical analysis, the χ2 test, linear regression, and Durbin-Watson statistic test. RESULTS: In total, 251 breast radiologists from 34 countries completed the survey. Most respondents were providing both screening and symptomatic services (137/251, 54.6%), working in an academic hospital (85/251, 33.9%) and reading 1000-4999 cases per year (109/251, 43.4%). More than half of them (133/251, 53%) had established QA measures in their workplace. Although less than one-third (71/251, 28.3%) had to participate in regular performance testing, the vast majority (190/251, 75.7%) agreed that a mandatory test would be helpful to improve their skills. CONCLUSION: QA measures were in place for more than half of the respondents working in screening and diagnostic mammography to evaluate their breast imaging performance. Although there were substantial differences between countries, the importance of having QA in the workplace and implemented was widely acknowledged by radiologists. CLINICAL RELEVANCE STATEMENT: Although several quality assurance (QA) measures of image interpretation are recommended by European bodies or national organisations, the QA in mammography is quite heterogenous between countries and reporting settings, and not always actively implemented across Europe. KEY POINTS: The first survey that presents radiologists' preferences regarding QA measures of image interpretation in mammography. Quality assurance measures in the workplace are better-established for breast screening compared to diagnostic mammography. Radiologists consider that performance tests would help to improve their mammography interpretation skills.


Subject(s)
Breast Neoplasms , Radiologists , Humans , Female , Mammography/methods , Breast , Surveys and Questionnaires , Europe , Breast Neoplasms/diagnostic imaging , Mass Screening
7.
Eur Radiol ; 2023 Nov 27.
Article in English | MEDLINE | ID: mdl-38008743

ABSTRACT

OBJECTIVES: To compare image quality of diffusion-weighted imaging (DWI) and contrast-enhanced breast MRI (DCE-T1) stratified by the amount of fibroglandular tissue (FGT) as a measure of breast density. METHODS: Retrospective, multi-reader, bicentric visual grading analysis study on breast density (A-D) and overall image and fat suppression quality of DWI and DCE-T1, scored on a standard 5-point Likert scale. Cross tabulations and visual grading characteristic (VGC) curves were calculated for fatty breasts (A/B) versus dense breasts (C/D). RESULTS: Image quality of DWI was higher in the case of increased breast density, with good scores (score 3-5) in 85.9% (D) and 88.4% (C), compared to 61.6% (B) and 53.5% (A). Overall image quality of DWI was in favor of dense breasts (C/D), with an area under the VGC curve of 0.659 (p < 0.001). Quality of DWI and DCE-T1 fat suppression increased with higher breast density, with good scores (score 3-5) for 86.9% and 45.7% of density D, and 90.2% and 42.9% of density C cases, compared to 76.0% and 33.6% for density B and 54.7% and 29.6% for density A (DWI and DCE-T1 respectively). CONCLUSIONS: Dense breasts show excellent fat suppression and substantially higher image quality in DWI images compared with non-dense breasts. These results support the setup of studies exploring DWI-based MR imaging without IV contrast for additional screening of women with dense breasts. CLINICAL RELEVANCE STATEMENT: Our findings demonstrate that image quality of DWI is robust in women with an increased amount of fibroglandular tissue, technically supporting the feasibility of exploring applications such as screening of women with mammographically dense breasts. KEY POINTS: • Image and fat suppression quality of diffusion-weighted imaging are dependent on the amount of fibroglandular tissue (FGT) which is closely connected to breast density. • Fat suppression quality in diffusion-weighted imaging of the breast is best in women with a high amount of fibroglandular tissue. • High image quality of diffusion-weighted imaging in women with a high amount of FGT in MRI supports that the technical feasibility of DWI can be explored in the additional screening of women with mammographically dense breasts.

8.
Lancet Oncol ; 23(9): 1201-1210, 2022 09.
Article in English | MEDLINE | ID: mdl-35952707

ABSTRACT

BACKGROUND: Primary chemotherapy in breast cancer poses a dilemma with regard to adjuvant locoregional radiotherapy, as guidelines for locoregional radiotherapy were originally based on pathology results of primary surgery. We aimed to evaluate the oncological safety of de-escalated locoregional radiotherapy in patients with cT1-2N1 breast cancer treated with primary chemotherapy, according to a predefined, consensus-based study guideline. METHODS: In this prospective registry study (RAPCHEM, BOOG 2010-03), patients referred to one of 17 participating radiation oncology centres in the Netherlands between Jan 1, 2011, and Jan 1, 2015, with cT1-2N1 breast cancer (one to three suspicious nodes on imaging before primary chemotherapy, of which at least one had been pathologically confirmed), and who were treated with primary chemotherapy and surgery of the breast and axilla were included in the study. The study guideline comprised three risk groups for locoregional recurrence, with corresponding locoregional radiotherapy recommendations: no chest wall radiotherapy and no regional radiotherapy in the low-risk group, only local radiotherapy in the intermediate-risk group, and locoregional radiotherapy in the high-risk group. Radiotherapy consisted of a biologically equivalent dose of 25 fractions of 2 Gy, with or without a boost. During the study period, the generally applied radiotherapy technique in the Netherlands was forward-planned or inverse-planned intensity modulated radiotherapy. 5-year follow-up was assessed, taking into account adherence to the study guideline, with locoregional recurrence rate as primary endpoint. We hypothesised that 5-year locoregional recurrence rate would be less than 4% (upper-limit 95% CI 7·8%). This study was registered at ClinicalTrials.gov, NCT01279304, and is completed. FINDINGS: 838 patients were eligible for 5-year follow-up analyses: 291 in the low-risk group, 370 in the intermediate-risk group, and 177 in the high-risk group. The 5-year locoregional recurrence rate in all patients was 2·2% (95% CI 1·4-3·4). The 5-year locoregional recurrence rate was 2·1% (0·9-4·3) in the low-risk group, 2·2% (1·0-4·1) in the intermediate-risk group, and 2·3% (0·8-5·5) in the high-risk group. If the study guideline was followed, the locoregional recurrence rate was 2·3% (0·8-5·3) for the low-risk group, 1·0% (0·2-3·4) for the intermediate-risk group, and 1·4% (0·3-4·5) for the high-risk group. INTERPRETATION: In this study, the 5-year locoregional recurrence rate was less than 4%, which supports our hypothesis that it is oncologically safe to de-escalate locoregional radiotherapy based on locoregional recurrence risk, in selected patients with cT1-2N1 breast cancer treated with primary chemotherapy, according to this predefined, consensus-based study guideline. FUNDING: Dutch Cancer Society. TRANSLATION: For the Dutch translation of the abstract see Supplementary Materials section.


Subject(s)
Breast Neoplasms , Radiation Oncology , Breast Neoplasms/drug therapy , Breast Neoplasms/radiotherapy , Female , Follow-Up Studies , Humans , Mastectomy , Neoplasm Recurrence, Local/pathology , Radiotherapy, Adjuvant , Registries
9.
N Engl J Med ; 381(22): 2091-2102, 2019 11 28.
Article in English | MEDLINE | ID: mdl-31774954

ABSTRACT

BACKGROUND: Extremely dense breast tissue is a risk factor for breast cancer and limits the detection of cancer with mammography. Data are needed on the use of supplemental magnetic resonance imaging (MRI) to improve early detection and reduce interval breast cancers in such patients. METHODS: In this multicenter, randomized, controlled trial in the Netherlands, we assigned 40,373 women between the ages of 50 and 75 years with extremely dense breast tissue and normal results on screening mammography to a group that was invited to undergo supplemental MRI or to a group that received mammography screening only. The groups were assigned in a 1:4 ratio, with 8061 in the MRI-invitation group and 32,312 in the mammography-only group. The primary outcome was the between-group difference in the incidence of interval cancers during a 2-year screening period. RESULTS: The interval-cancer rate was 2.5 per 1000 screenings in the MRI-invitation group and 5.0 per 1000 screenings in the mammography-only group, for a difference of 2.5 per 1000 screenings (95% confidence interval [CI], 1.0 to 3.7; P<0.001). Of the women who were invited to undergo MRI, 59% accepted the invitation. Of the 20 interval cancers that were diagnosed in the MRI-invitation group, 4 were diagnosed in the women who actually underwent MRI (0.8 per 1000 screenings) and 16 in those who did not accept the invitation (4.9 per 1000 screenings). The MRI cancer-detection rate among the women who actually underwent MRI screening was 16.5 per 1000 screenings (95% CI, 13.3 to 20.5). The positive predictive value was 17.4% (95% CI, 14.2 to 21.2) for recall for additional testing and 26.3% (95% CI, 21.7 to 31.6) for biopsy. The false positive rate was 79.8 per 1000 screenings. Among the women who underwent MRI, 0.1% had either an adverse event or a serious adverse event during or immediately after the screening. CONCLUSIONS: The use of supplemental MRI screening in women with extremely dense breast tissue and normal results on mammography resulted in the diagnosis of significantly fewer interval cancers than mammography alone during a 2-year screening period. (Funded by the University Medical Center Utrecht and others; DENSE ClinicalTrials.gov number, NCT01315015.).


Subject(s)
Breast Density , Breast Neoplasms/diagnostic imaging , Early Detection of Cancer/methods , Magnetic Resonance Imaging , Mammography , Aged , Breast/diagnostic imaging , Breast/pathology , Breast Neoplasms/epidemiology , False Positive Reactions , Female , Follow-Up Studies , Humans , Middle Aged , Sensitivity and Specificity
10.
Radiology ; 302(1): 29-36, 2022 01.
Article in English | MEDLINE | ID: mdl-34609196

ABSTRACT

Background Supplemental screening with MRI has proved beneficial in women with extremely dense breasts. Most MRI examinations show normal anatomic and physiologic variation that may not require radiologic review. Thus, ways to triage these normal MRI examinations to reduce radiologist workload are needed. Purpose To determine the feasibility of an automated triaging method using deep learning (DL) to dismiss the highest number of MRI examinations without lesions while still identifying malignant disease. Materials and Methods This secondary analysis of data from the Dense Tissue and Early Breast Neoplasm Screening, or DENSE, trial evaluated breast MRI examinations from the first screening round performed in eight hospitals between December 2011 and January 2016. A DL model was developed to differentiate between breasts with lesions and breasts without lesions. The model was trained to dismiss breasts with normal phenotypical variation and to triage lesions (Breast Imaging Reporting and Data System [BI-RADS] categories 2-5) using eightfold internal-external validation. The model was trained on data from seven hospitals and tested on data from the eighth hospital, alternating such that each hospital was used once as an external test set. Performance was assessed using receiver operating characteristic analysis. At 100% sensitivity for malignant disease, the fraction of examinations dismissed from radiologic review was estimated. Results A total of 4581 MRI examinations of extremely dense breasts from 4581women (mean age, 54.3 years; interquartile range, 51.5-59.8 years) were included. Of the 9162 breasts, 838 had at least one lesion (BI-RADS category 2-5, of which 77 were malignant) and 8324 had no lesions. At 100% sensitivity for malignant lesions, the DL model considered 90.7% (95% CI: 86.7, 94.7) of the MRI examinations with lesions to be nonnormal and triaged them to radiologic review. The DL model dismissed 39.7% (95% CI: 30.0, 49.4) of the MRI examinations without lesions. The DL model had an average area under the receiver operating characteristic curve of 0.83 (95% CI: 0.80, 0.85) in the differentiation between normal breast MRI examinations and MRI examinations with lesions. Conclusion Automated analysis of breast MRI examinations in women with dense breasts dismissed nearly 40% of MRI scans without lesions while not missing any cancers. ClinicalTrials.gov: NCT01315015 © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Joe in this issue.


Subject(s)
Breast Density , Breast Neoplasms/diagnostic imaging , Deep Learning , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Triage/methods , Breast/diagnostic imaging , Feasibility Studies , Female , Humans , Middle Aged
11.
Radiology ; 302(2): 276-283, 2022 02.
Article in English | MEDLINE | ID: mdl-34751612

ABSTRACT

Background In the Dutch breast cancer screening program, mammograms are preread by technologists to identify possible abnormalities, leading to "warning signals" (an audible and visual alert if the technologist observed an abnormality suspicious for cancer) for radiologists. The best moment to present these warning signals is unknown. Purpose To determine the effect that blinding of technologists' warning signals has on radiologists' early screening outcome measures during interpretation of mammograms. Materials and Methods In this prospective study from September 2017 to May 2019, on alternating months, radiologists were either blinded or nonblinded to the warning signals of the technologist when interpreting screening mammograms for breast cancer. All discrepancies between radiologists and technologists were reviewed during quality assurance sessions every 6 weeks, which could result in secondary recalls. The outcome measures of this study were recall rate, cancer detection rate, and positive predictive value of recall. A χ2 test was used to test for differences between the two groups. Results During the study period, 109 596 women (mean age, 62 years ± 7 [standard deviation]), including 53 291 in the blinded and 56 305 in the nonblinded groups, participated. The overall recall rate (including secondary recalls) was lower for women in the blinded group than in the nonblinded group (blinded: 1140 of 53 291 women [2.1%], nonblinded: 1372 of 56 305 women [2.4%]; P = .001). There was no evidence of cancer detection rate differences between the groups (blinded: 349 of 53 291 women [6.5 per 1000 screening examinations], nonblinded: 360 of 56 305 women [6.4 per 1000 screening examinations]; P = .75). The blinded group thus had a higher positive predictive value of recall (blinded: 349 of 1140 women [30.6%], nonblinded: 360 of 1372 women [26.2%]; P = .02). Conclusion While interpreting screening mammograms for breast cancer, radiologists blinded to technologists' warning signals had lower recall rates with higher positive predictive values than nonblinded radiologists, yet cancer detection rates seemed to remain unchanged. See also the editorial by Hofvind and Lee in this issue. © RSNA, 2021.


Subject(s)
Allied Health Personnel , Breast Neoplasms/diagnostic imaging , Clinical Competence , Early Detection of Cancer , Female , Humans , Mammography , Middle Aged , Netherlands , Observer Variation , Prospective Studies , Technology, Radiologic
12.
BMC Cancer ; 22(1): 305, 2022 Mar 22.
Article in English | MEDLINE | ID: mdl-35317766

ABSTRACT

BACKGROUND: Breast cancer screening and improving imaging techniques have led to an increase in the detection rate of early, nonpalpable breast cancers. For early breast cancer, breast conserving surgery is an effective and safe treatment. Accurate intraoperative lesion localization during breast conserving surgery is essential for adequate surgical margins while sparing surrounding healthy tissue to achieve optimal cosmesis. Preoperative wire localization and radioactive seed localization are accepted standard methods to guide surgical excision of nonpalpable breast lesions. However, these techniques present significant limitations. Radiofrequency identification (RFID) technology offers a new, nonradioactive method for localizing nonpalpable breast lesions in patients undergoing breast conserving surgery. This study aims to evaluate the feasibility of RFID surgical guidance for nonpalpable breast lesions. METHODS: This multicenter prospective cohort study was approved by the Institutional Review Board of the University Medical Center Utrecht. Written informed consent is obtained from all participants. Women with nonpalpable, histologically proven in situ or invasive breast cancer, who can undergo breast conserving surgery with RFID localization are considered eligible for participation. An RFID tag is placed under ultrasound guidance, up to 30 days preoperatively. The surgeon localizes the RFID tag with a radiofrequency reader that provides audible and visual real-time surgical guidance. The primary study outcome is the percentage of irradical excisions and reexcision rate, which will be compared to standards of the National Breast Cancer Organisation Netherlands (NABON)(≤ 15% irradical excisions of invasive carcinomas). Secondary outcomes include user acceptability/experiences, learning curve, duration and ease of the placement- and surgical procedure and adverse events. DISCUSSION: This study evaluates the feasibility of RFID surgical guidance for nonpalpable breast lesions. Results may have implications for the future localization techniques in women with nonpalpable breast cancer undergoing breast conserving surgery. TRIAL REGISTRATION: Netherlands National Trial Register, NL8019 , registered on September 12th 2019.


Subject(s)
Breast Neoplasms/surgery , Mastectomy, Segmental/methods , Radio Frequency Identification Device , Adolescent , Adult , Breast Neoplasms/diagnosis , Feasibility Studies , Female , Humans , Margins of Excision , Prospective Studies , Young Adult
13.
Eur Radiol ; 32(11): 7463-7469, 2022 Nov.
Article in English | MEDLINE | ID: mdl-35482123

ABSTRACT

The magnitude of the tradeoff between recall rate (RR) and cancer detection rate (CDR) in breast-cancer screening is not clear, and it is expected to depend on target population and screening program characteristics. Multi-reader multi-case research studies, which may be used to estimate this tradeoff, rely on enriched datasets with artificially high prevalence rates, which may bias the results. Furthermore, readers participating in research studies are subject to "laboratory" effects, which can alter their performance relative to actual practice. The Recall and detection Of breast Cancer in Screening (ROCS) trial uses a novel data acquisition system that minimizes these limitations while obtaining an estimate of the RR-CDR curve during actual practice in the Dutch National Breast Cancer Screening Program. ROCS involves collection of at least 40,000 probability-of-malignancy ratings from at least 20 radiologists during interpretation of approximately 2,000 digital mammography screening cases each. With the use of custom-built software on a tablet, and a webcam, this data was obtained in the usual reading environment with minimal workflow disruption and without electronic access to the review workstation software. Comparison of the results to short- and medium-term follow-up allows for estimation of the RR-CDR and receiver operating characteristics curves, respectively. The anticipated result of the study is that performance-based evidence from practice will be available to determine the optimal operating point for breast-cancer screening. In addition, this data will be useful as a benchmark when evaluating the impact of potential new screening technologies, such as digital breast tomosynthesis or artificial intelligence. KEY POINTS: • The ROCS trial aims to estimate the recall rate-cancer detection rate curve during actual screening practice in the Dutch National Breast Cancer Screening Program. • The study design is aimed at avoiding the influence of the "laboratory effect" in usual observer performance studies. • The use of a tablet and a webcam allows for the acquisition of probability of malignancy ratings without access to the review workstation software.


Subject(s)
Breast Neoplasms , Early Detection of Cancer , Female , Humans , Artificial Intelligence , Breast Neoplasms/pathology , Early Detection of Cancer/methods , Mammography/methods , Mass Screening/methods
14.
Eur Radiol ; 32(6): 4036-4045, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35258677

ABSTRACT

Breast density is an independent risk factor for the development of breast cancer and also decreases the sensitivity of mammography for screening. Consequently, women with extremely dense breasts face an increased risk of late diagnosis of breast cancer. These women are, therefore, underserved with current mammographic screening programs. The results of recent studies reporting on contrast-enhanced breast MRI as a screening method in women with extremely dense breasts provide compelling evidence that this approach can enable an important reduction in breast cancer mortality for these women and is cost-effective. Because there is now a valid option to improve breast cancer screening, the European Society of Breast Imaging (EUSOBI) recommends that women should be informed about their breast density. EUSOBI thus calls on all providers of mammography screening to share density information with the women being screened. In light of the available evidence, in women aged 50 to 70 years with extremely dense breasts, the EUSOBI now recommends offering screening breast MRI every 2 to 4 years. The EUSOBI acknowledges that it may currently not be possible to offer breast MRI immediately and everywhere and underscores that quality assurance procedures need to be established, but urges radiological societies and policymakers to act on this now. Since the wishes and values of individual women differ, in screening the principles of shared decision-making should be embraced. In particular, women should be counselled on the benefits and risks of mammography and MRI-based screening, so that they are capable of making an informed choice about their preferred screening method. KEY POINTS: • The recommendations in Figure 1 summarize the key points of the manuscript.


Subject(s)
Breast Density , Breast Neoplasms , Breast/diagnostic imaging , Breast Neoplasms/diagnostic imaging , Early Detection of Cancer/methods , Female , Humans , Mammography/methods , Mass Screening/methods
15.
Radiology ; 301(2): 283-292, 2021 11.
Article in English | MEDLINE | ID: mdl-34402665

ABSTRACT

Background High breast density increases breast cancer risk and lowers mammographic sensitivity. Supplemental MRI screening improves cancer detection but increases the number of false-positive screenings. Thus, methods to distinguish true-positive MRI screening results from false-positive ones are needed. Purpose To build prediction models based on clinical characteristics and MRI findings to reduce the rate of false-positive screening MRI findings in women with extremely dense breasts. Materials and Methods Clinical characteristics and MRI findings in Dutch breast cancer screening participants (age range, 50-75 years) with positive first-round MRI screening results (Breast Imaging Reporting and Data System 3, 4, or 5) after a normal screening mammography with extremely dense breasts (Volpara density category 4) were prospectively collected within the randomized controlled Dense Tissue and Early Breast Neoplasm Screening (DENSE) trial from December 2011 through November 2015. In this secondary analysis, prediction models were built using multivariable logistic regression analysis to distinguish true-positive MRI screening findings from false-positive ones. Results Among 454 women (median age, 52 years; interquartile range, 50-57 years) with a positive MRI result in a first supplemental MRI screening round, 79 were diagnosed with breast cancer (true-positive findings), and 375 had false-positive MRI results. The full prediction model (area under the receiver operating characteristics curve [AUC], 0.88; 95% CI: 0.84, 0.92), based on all collected clinical characteristics and MRI findings, could have prevented 45.5% (95% CI: 39.6, 51.5) of false-positive recalls and 21.3% (95% CI: 15.7, 28.3) of benign biopsies without missing any cancers. The model solely based on readily available MRI findings and age had a comparable performance (AUC, 0.84; 95% CI: 0.79, 0.88; P = .15) and could have prevented 35.5% (95% CI: 30.4, 41.1) of false-positive MRI screening results and 13.0% (95% CI: 8.8, 18.6) of benign biopsies. Conclusion Prediction models based on clinical characteristics and MRI findings may be useful to reduce the false-positive first-round screening MRI rate and benign biopsy rate in women with extremely dense breasts. Clinical trial registration no. NCT01315015 © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Imbriaco in this issue.


Subject(s)
Breast Density , Breast Neoplasms/diagnostic imaging , Magnetic Resonance Imaging/methods , Aged , Breast/diagnostic imaging , False Positive Reactions , Female , Humans , Middle Aged , Netherlands , Prospective Studies , Reproducibility of Results , Sensitivity and Specificity
16.
Radiology ; 299(2): 278-286, 2021 05.
Article in English | MEDLINE | ID: mdl-33724062

ABSTRACT

Background In the first (prevalent) supplemental MRI screening round of the Dense Tissue and Early Breast Neoplasm Screening (DENSE) trial, a considerable number of breast cancers were found at the cost of an increased false-positive rate (FPR). In incident screening rounds, a lower cancer detection rate (CDR) is expected due to a smaller pool of prevalent cancers, and a reduced FPR, due to the availability of prior MRI examinations. Purpose To investigate screening performance indicators of the second round (incidence round) of the DENSE trial. Materials and Methods The DENSE trial (ClinicalTrials.gov: NCT01315015) is embedded within the Dutch population-based biennial mammography screening program for women aged 50-75 years. MRI examinations were performed between December 2011 and January 2016. Women were eligible for the second round when they again had a negative screening mammogram 2 years after their first MRI. The recall rate, biopsy rate, CDR, FPR, positive predictive values, and distributions of tumor characteristics were calculated and compared with results of the first round using 95% CIs and χ2 tests. Results A total of 3436 women (median age, 56 years; interquartile range, 48-64 years) underwent a second MRI screening. The CDR was 5.8 per 1000 screening examinations (95% CI: 3.8, 9.0) compared with 16.5 per 1000 screening examinations (95% CI: 13.3, 20.5) in the first round. The FPR was 26.3 per 1000 screening examinations (95% CI: 21.5, 32.3) in the second round versus 79.8 per 1000 screening examinations (95% CI: 72.4, 87.9) in the first round. The positive predictive value for recall was 18% (20 of 110 participants recalled; 95% CI: 12.1, 26.4), and the positive predictive value for biopsy was 24% (20 of 84 participants who underwent biopsy; 95% CI: 16.0, 33.9), both comparable to that of the first round. All tumors in the second round were stage 0-I and node negative. Conclusion The incremental cancer detection rate in the second round was 5.8 per 1000 screening examinations-compared with 16.5 per 1000 screening examinations in the first round. This was accompanied by a strong reduction in the number of false-positive results. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Moy and Gao in this issue.


Subject(s)
Breast Density , Breast Neoplasms/diagnostic imaging , Magnetic Resonance Imaging , Mass Screening/methods , Biopsy , Breast Neoplasms/epidemiology , Early Detection of Cancer , False Positive Reactions , Female , Humans , Incidence , Middle Aged , Netherlands/epidemiology
17.
Prev Med ; 151: 106602, 2021 10.
Article in English | MEDLINE | ID: mdl-34217417

ABSTRACT

The COVID-19 pandemic forced the Dutch national breast screening program to a halt in week 12, 2020. In week 26, the breast program was resumed at 40% capacity, which increased to 60% in week 34. We examined the impact of the suspension and restart of the screening program on the incidence of screen-detected and non-screen-detected breast cancer. We selected women aged 50-74, diagnosed during weeks 2-35 of 2018 (n = 7250), 2019 (n = 7302), or 2020 (n = 5306), from the Netherlands Cancer Registry. Weeks 2-35 were divided in seven periods, based on events occurring at the start of the COVID-19 pandemic. Incidence of screen-detected and non-screen-detected tumors was calculated overall and by age group, cT-stage, and cTNM-stage for each period in 2020, and compared to the incidence in the same period of 2018/2019 (averaged). The incidence of screen-detected tumors decreased during weeks 12-13, reached almost zero during weeks 14-25, and increased during weeks 26-35. Incidence of non-screen-detected tumors decreased to a lesser extent during weeks 12-16. The decrease in incidence was seen in all age groups and mainly occurred for cTis, cT1, DCIS, and stage I tumors. Due to the suspension of the breast cancer screening program, and the restart at reduced capacity, the incidence of screen-detected breast tumors decreased by 67% during weeks 9-35 2020, which equates to about 2000 potentially delayed breast cancer diagnoses. Up to August 2020 there was no indication of a shift towards higher stage breast cancers after restart of the screening.


Subject(s)
Breast Neoplasms , COVID-19 , Breast Neoplasms/diagnosis , Breast Neoplasms/epidemiology , Early Detection of Cancer , Female , Humans , Incidence , Mammography , Mass Screening , Netherlands/epidemiology , Pandemics , SARS-CoV-2
18.
Br J Cancer ; 123(2): 325-332, 2020 07.
Article in English | MEDLINE | ID: mdl-32390006

ABSTRACT

BACKGROUND: Delay in detection of breast cancer may worsen tumour characteristics, with progression of tumour size and a higher risk of metastatic lymph nodes. The purpose of this study was to investigate delayed breast cancer diagnosis after repeated recall for the same mammographic abnormality at screening. METHODS: This was a retrospective study performed in two cohorts of women enrolled in a mammography screening programme in the Netherlands. All women aged 50-75 who underwent biennial screening mammography either between January 1, 1997 and December 31, 2006 (cohort 1) or between January 1, 2007 and December 31, 2016 (cohort 2) were included. RESULTS: The cohorts showed no difference in proportions of women with delayed breast cancer diagnosis of at least 2 years (2.2% versus 2.8%, P = 0.29). Most delays were caused by incorrect BI-RADS classifications after recall (74.2%). An increase in mean tumour size was seen when comparing sizes at initial false-negative recall and at diagnosis of breast cancer (P < 0.001). CONCLUSIONS: The proportion of women with a long delay in breast cancer confirmation following repeated recall at screening mammography has not decreased during 20 years of screening. These delays lead to larger tumour size at detection and may negatively influence prognosis.


Subject(s)
Breast Neoplasms/diagnosis , Breast Neoplasms/epidemiology , Early Detection of Cancer , Prognosis , Aged , Breast Neoplasms/pathology , Female , Follow-Up Studies , Humans , Mammography/methods , Middle Aged , Netherlands/epidemiology , Time Factors
19.
Radiology ; 297(1): 40-48, 2020 10.
Article in English | MEDLINE | ID: mdl-32749212

ABSTRACT

BackgroundDigital breast tomosynthesis (DBT) is a promising screening test, but its outcomes and cost-effectiveness remain uncertain.PurposeTo determine if biennial DBT is cost-effective in a screening setting, when compared with digital mammography (DM) in the Netherlands, and to quantify the uncertainty.Materials and MethodsIn this study, performed from March 2018 to February 2019, the MIcrosimulation SCreening ANalysis model was used to conduct a probabilistic sensitivity analysis (PSA), consisting of 10 000 model runs with 1 000 000 women simulated per run. The Bayesian Cost-Effectiveness Analysis package and the Sheffield Accelerated Value of Information tool were used to process PSA outcomes. Two simulated cohorts born in 1970 were invited to undergo biennial screening between ages 50 and 74 years-one cohort was assigned to DM screening, and one was assigned to DBT screening. DM input parameters were based on data from the Dutch breast cancer screening program. DBT parameters were based on literature and expert opinion. Willingness-to-pay thresholds of €20 000 ($22 000) and €35 000 ($38 500) per life-year gained (LYG) were considered. Effects and costs were discounted at 3.5% per year.ResultsDBT resulted in a gain of 13 additional life-years per 1000 women invited to screening (7% increase, 13 of 193), followed over lifetime, compared with DM and led to 2% (four of 159) fewer false-positive results. DBT screening led to incremental discounted lifetime effects of 5.09 LYGs (95% confidence interval: -0.80, 9.70) and an increase in lifetime costs of €137 555 ($151 311) per 1000 women (95% confidence interval: €31 093 [$34 202], €263 537 [$289 891]) compared with DM, resulting in a mean incremental cost-effectiveness ratio of €27 023 ($29 725) per LYG. The probability of DBT being more cost-effective was 0.36 at €20 000 and 0.66 at €35 000 per LYG.ConclusionSwitching from digital mammography to biennial digital breast tomosynthesis is not cost-effective at a willingness-to-pay threshold of €20 000 per life-year gained, but digital breast tomosynthesis has a higher probability of being more cost-effective than digital mammography at a threshold of €35 000 per life-year gained.© RSNA, 2020Online supplemental material is available for this article.See also the editorial by Slanetz in this issue.


Subject(s)
Breast Neoplasms/diagnostic imaging , Mammography/economics , Aged , Bayes Theorem , Cost-Benefit Analysis , Early Detection of Cancer , Female , Humans , Life Expectancy , Mass Screening , Middle Aged , Sensitivity and Specificity
20.
Eur Radiol ; 30(10): 5437-5445, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32382844

ABSTRACT

OBJECTIVES: To evaluate at which sensitivity digital breast tomosynthesis (DBT) would become cost-effective compared to digital mammography (DM) in a population breast cancer screening program, given a constant estimate of specificity. METHODS: In a microsimulation model, the cost-effectiveness of biennial screening for women aged 50-75 was simulated for three scenarios: DBT for women with dense breasts and DM for women with fatty breasts (scenario 1), DBT for the whole population (scenario 2) or maintaining DM screening (reference). For DM, sensitivity was varied depending on breast density from 65 to 87%, and for DBT from 65 to 100%. The specificity was set at 96.5% for both DM and DBT. Direct medical costs were considered, including screening, biopsy and treatment costs. Scenarios were considered to be cost-effective if the incremental cost-effectiveness ratio (ICER) was below €20,000 per life year gain (LYG). RESULTS: For both scenarios, the ICER was more favourable at increasing DBT sensitivity. Compared with DM screening, 0.8-10.2% more LYGs were found when DBT sensitivity was at least 75% for scenario 1, and 4.7-18.7% when DBT sensitivity was at least 80% for scenario 2. At €96 per DBT, scenario 1 was cost-effective at a DBT sensitivity of at least 90%, and at least 95% for scenario 2. At €80 per DBT, these values decreased to 80% and 90%, respectively. CONCLUSION: DBT is more likely to be a cost-effective alternative to mammography in women with dense breasts. Whether DBT could be cost-effective in a general population highly depends on DBT costs. KEY POINTS: • DBT could be a cost-effective screening modality for women with dense breasts when its sensitivity is at least 90% at a maximum cost per screen of €96. • DBT has the potential to be cost-effective for screening all women when sensitivity is at least 90% at a maximum cost per screen of €80. • Whether DBT could be used as an alternative to mammography for screening all women is highly dependent on the cost of DBT per screen.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast Neoplasms/economics , Cost-Benefit Analysis , Early Detection of Cancer/economics , Mammography/economics , Mass Screening/economics , Aged , Biopsy , Breast/diagnostic imaging , Breast/pathology , Breast Density , Computer Simulation , Europe , Female , Health Care Costs , Humans , Markov Chains , Middle Aged , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL