Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters

Database
Language
Publication year range
1.
Laryngoscope ; 131(6): E2038-E2043, 2021 06.
Article in English | MEDLINE | ID: mdl-33590898

ABSTRACT

OBJECTIVES: The objectives were to characterize the effects of wearing face coverings on: 1) acoustic speech cues, and 2) speech recognition of patients with hearing loss who listen with a cochlear implant. METHODS: A prospective cohort study was performed in a tertiary referral center between July and September 2020. A female talker recorded sentences in three conditions: no face covering, N95 mask, and N95 mask plus a face shield. Spectral differences were analyzed between speech produced in each condition. The speech recognition in each condition for twenty-three adult patients with at least 6 months of cochlear implant use was assessed. RESULTS: Spectral analysis demonstrated preferential attenuation of high-frequency speech information with the N95 mask plus face shield condition compared to the other conditions. Speech recognition did not differ significantly between the uncovered (median 90% [IQR 89%-94%]) and N95 mask conditions (91% [IQR 86%-94%]; P = .253); however, speech recognition was significantly worse in the N95 mask plus face shield condition (64% [IQR 48%-75%]) compared to the uncovered (P < .001) or N95 mask (P < .001) conditions. CONCLUSIONS: The type and combination of protective face coverings used have differential effects on attenuation of speech information, influencing speech recognition of patients with hearing loss. In the face of the COVID-19 pandemic, there is a need to protect patients and clinicians from spread of disease while maximizing patient speech recognition. The disruptive effect of wearing a face shield in conjunction with a mask may prompt clinicians to consider alternative eye protection, such as goggles, in appropriate clinical situations. LEVEL OF EVIDENCE: 3 Laryngoscope, 131:E2038-E2043, 2021.


Subject(s)
Cochlear Implants , N95 Respirators , Perceptual Masking , Speech Perception , Adult , Cohort Studies , Cues , Female , Hearing Loss/physiopathology , Humans , Male , Perceptual Masking/physiology , Prospective Studies , Sound Spectrography , Speech Acoustics , Speech Discrimination Tests , Speech Perception/physiology
2.
Otol Neurotol ; 42(8): 1149-1155, 2021 09 01.
Article in English | MEDLINE | ID: mdl-33859134

ABSTRACT

OBJECTIVES: To characterize the relationship between cochlear duct length (CDL) and initial hearing preservation among cochlear implant recipients of a fully inserted 31.5 mm flexible lateral wall electrode array. STUDY DESIGN: Retrospective review. SETTING: Tertiary academic referral center. PATIENTS: Adult cochlear implant recipients who presented preoperatively with unaided hearing detection thresholds of ≤ 65 dB HL at 125 Hz and underwent cochlear implantation with a 31.5 mm flexible lateral wall array. INTERVENTION: Cochlear implantation with a hearing preservation surgical approach. MAIN OUTCOME MEASURES: Computed tomography was reviewed to determine CDL. Hearing preservation was characterized by the shift in low-frequency pure-tone average (LFPTA; 125, 250, and 500 Hz), and shift in individual unaided hearing detection thresholds at 125, 250, and 500 Hz. RESULTS: Nineteen patients met the criteria for inclusion. The mean CDL was 34.2 mm (range: 30.8-36.5 mm). Recipients experienced a mean LFPTA shift of 27.6 dB HL (range: 10-50 dB HL). Significant, negative correlations were observed between CDL and smaller threshold shifts at individual frequencies and LFPTA (p ≤ 0.048). CONCLUSION: A longer CDL is associated with greater likelihood of preserving low-frequency hearing with long arrays. Low-frequency hearing preservation is feasible with fully inserted long flexible arrays within the initial months after cochlear implantation. Preoperative measurement of CDL may facilitate a more individualized approach in array selection to permit optimal cochlear coverage while enhancing hearing preservation outcomes.


Subject(s)
Cochlear Implantation , Cochlear Implants , Adult , Audiometry, Pure-Tone , Auditory Threshold , Cochlear Duct , Hearing , Humans , Retrospective Studies , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL