Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
1.
Radiology ; 310(3): e231429, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38530172

ABSTRACT

Background Differentiating between benign and malignant vertebral fractures poses diagnostic challenges. Purpose To investigate the reliability of CT-based deep learning models to differentiate between benign and malignant vertebral fractures. Materials and Methods CT scans acquired in patients with benign or malignant vertebral fractures from June 2005 to December 2022 at two university hospitals were retrospectively identified based on a composite reference standard that included histopathologic and radiologic information. An internal test set was randomly selected, and an external test set was obtained from an additional hospital. Models used a three-dimensional U-Net encoder-classifier architecture and applied data augmentation during training. Performance was evaluated using the area under the receiver operating characteristic curve (AUC) and compared with that of two residents and one fellowship-trained radiologist using the DeLong test. Results The training set included 381 patients (mean age, 69.9 years ± 11.4 [SD]; 193 male) with 1307 vertebrae (378 benign fractures, 447 malignant fractures, 482 malignant lesions). Internal and external test sets included 86 (mean age, 66.9 years ± 12; 45 male) and 65 (mean age, 68.8 years ± 12.5; 39 female) patients, respectively. The better-performing model of two training approaches achieved AUCs of 0.85 (95% CI: 0.77, 0.92) in the internal and 0.75 (95% CI: 0.64, 0.85) in the external test sets. Including an uncertainty category further improved performance to AUCs of 0.91 (95% CI: 0.83, 0.97) in the internal test set and 0.76 (95% CI: 0.64, 0.88) in the external test set. The AUC values of residents were lower than that of the best-performing model in the internal test set (AUC, 0.69 [95% CI: 0.59, 0.78] and 0.71 [95% CI: 0.61, 0.80]) and external test set (AUC, 0.70 [95% CI: 0.58, 0.80] and 0.71 [95% CI: 0.60, 0.82]), with significant differences only for the internal test set (P < .001). The AUCs of the fellowship-trained radiologist were similar to those of the best-performing model (internal test set, 0.86 [95% CI: 0.78, 0.93; P = .39]; external test set, 0.71 [95% CI: 0.60, 0.82; P = .46]). Conclusion Developed models showed a high discriminatory power to differentiate between benign and malignant vertebral fractures, surpassing or matching the performance of radiology residents and matching that of a fellowship-trained radiologist. © RSNA, 2024 See also the editorial by Booz and D'Angelo in this issue.


Subject(s)
Deep Learning , Spinal Fractures , Humans , Female , Male , Aged , Reproducibility of Results , Retrospective Studies , Spinal Fractures/diagnostic imaging , Multidetector Computed Tomography , Hospitals, University
2.
J Magn Reson Imaging ; 59(5): 1542-1552, 2024 May.
Article in English | MEDLINE | ID: mdl-37501387

ABSTRACT

BACKGROUND: Several magnetic resonance (MR) techniques have been suggested for radiation-free imaging of osseous structures. PURPOSE: To compare the diagnostic value of ultra-short echo time and gradient echo T1-weighted MRI for the assessment of vertebral pathologies using histology and computed tomography (CT) as the reference standard. STUDY TYPE: Prospective. SUBJECTS: Fifty-nine lumbar vertebral bodies harvested from 20 human cadavers (donor age 73 ± 13 years; 9 male). FIELD STRENGTH/SEQUENCE: Ultra-short echo time sequence optimized for both bone (UTEb) and cartilage (UTEc) imaging and 3D T1-weighted gradient-echo sequence (T1GRE) at 3 T; susceptibility-weighted imaging (SWI) gradient echo sequence at 1.5 T. CT was performed on a dual-layer dual-energy CT scanner using a routine clinical protocol. ASSESSMENT: Histopathology and conventional CT were acquired as standard of reference. Semi-quantitative and quantitative morphological features of degenerative changes of the spines were evaluated by four radiologists independently on CT and MR images independently and blinded to all other information. Features assessed were osteophytes, endplate sclerosis, visualization of cartilaginous endplate, facet joint degeneration, presence of Schmorl's nodes, and vertebral dimensions. Vertebral disorders were assessed by a pathologist on histology. STATISTICAL TESTS: Agreement between T1GRE, SWI, UTEc, and UTEb sequences and CT imaging and histology as standard of reference were assessed using Fleiss' κ and intra-class correlation coefficients, respectively. RESULTS: For the morphological assessment of osteophytes and endplate sclerosis, the overall agreement between SWI, T1GRE, UTEb, and UTEc with the reference standard (histology combined with CT) was moderate to almost perfect for all readers (osteophytes: SWI, κ range: 0.68-0.76; T1GRE: 0.92-1.00; UTEb: 0.92-1.00; UTEc: 0.77-0.85; sclerosis: SWI, κ range: 0.60-0.70; T1GRE: 0.77-0.82; UTEb: 0.81-0.92; UTEc: 0.61-0.71). For the visualization of the cartilaginous endplate, UTEc showed the overall best agreement with the reference standard (histology) for all readers (κ range: 0.85-0.93). DATA CONCLUSIONS: Morphological assessment of vertebral pathologies was feasible and accurate using the MR-based bone imaging sequences compared to CT and histopathology. T1GRE showed the overall best performance for osseous changes and UTEc for the visualization of the cartilaginous endplate. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY: Stage 2.


Subject(s)
Osteophyte , Humans , Male , Middle Aged , Aged , Aged, 80 and over , Prospective Studies , Sclerosis , Magnetic Resonance Imaging/methods , Tomography, X-Ray Computed/methods , Lumbar Vertebrae/diagnostic imaging , Reference Standards
3.
Stroke ; 54(5): 1246-1256, 2023 05.
Article in English | MEDLINE | ID: mdl-37051911

ABSTRACT

BACKGROUND: Bone or cartilage anomalies with affection of brain supplying arteries are a potential structural cause for ischemic stroke. In the following, we termed this entity bony stroke. Due to rarity of their description, there is no standardized workup and therapy for bony strokes. METHODS: Retrospectively, we extracted diagnostic and therapeutic workup of all patients considered to have had a bony stroke between January 2017 to March 2022 at our comprehensive care center. RESULTS: In total, 6 patients classified as a bony stroke were identified among 4200 acute patients with ischemic stroke treated during the study period. Each patient had recurrent ischemic strokes in the dependent vascular territory before diagnosis. Diagnosis was achieved by a combination of imaging devices, including sonography, computed tomography, and magnetic resonance imaging. In addition to conventional static imaging, the application of dynamic imaging modalities with the patients' head in rotation or reclination confirmed a vessel affection following head movements in 3 patients (50%). Treatment options were interdisciplinary assessed and included the following: conservative treatment (n=1), endovascular stenting (n=2) or occlusion (n=2), surgical removal of bone/ cartilage (n=2), and surgical bypass treatment (n=1). In follow-up (mean 11.7 months), no patient experienced further ischemia. CONCLUSIONS: As a differential diagnosis, bony strokes may be considered in patients with recurrent ischemic stroke of unknown cause in one dependent vascular territory. Interdisciplinary evaluation and treatment may eliminate risk of stroke recurrence.


Subject(s)
Brain Ischemia , Ischemic Stroke , Stroke , Humans , Ischemic Stroke/complications , Stress, Mechanical , Retrospective Studies , Arteries , Brain , Brain Ischemia/therapy
4.
Eur Radiol ; 33(2): 1445-1455, 2023 Feb.
Article in English | MEDLINE | ID: mdl-35980430

ABSTRACT

OBJECTIVES: To evaluate the performance of single-echo Dixon water-fat imaging and computed tomography (CT)-like imaging based on a single ultrashort echo time (sUTE) MR sequence for imaging of vertebral fractures as well as degenerative bone changes of the spine in comparison to conventional CT and MR sequences. METHODS: Thirty patients with suspected acute vertebral fractures were examined using a 3-T MRI, including an sUTE sequence as well as short-tau inversion recovery (STIR) and T1-weighted sequences. During postprocessing, water-fat separation was performed by solving the smoothness-constrained inverse water-fat problem based on a single-complex UTE image. By removing the unwanted low-frequency phase terms, additional MR-based susceptibility-weighted-like (SW-like) images with CT-like contrast were created. Two radiologists evaluated semi-quantitative and quantitative features of fractures and degenerative changes independently and separately on CT and MR images. RESULTS: In total, all 58 fractures were accurately detected of whom 24 were correctly classified as acute fractures with an edema detected on the water-fat-separated UTE images, using STIR and T1w sequences as standard of reference. For the morphological assessment of fractures and degenerative changes, the overall agreement between SW-like images and CT was substantial to excellent (e.g., Genant: κ 0.90 (95% confidence interval 0.54-1.00); AO/Magerl: κ 0.75 (95% confidence interval 0.43-1.00)). Overall inter-reader agreement for water-fat-separated UTE images and SW-like images was substantial to almost perfect. CONCLUSION: Detection and assessment of vertebral fractures and degenerative bone changes of the spine were feasible and accurate using water-fat-separated images as well as SW-like images, both derived from the same sUTE-Dixon sequence. KEY POINTS: • The detection of acute vertebral fractures was feasible using water-fat-separated images and CT-like images reconstructed from one sUTE sequence. • Assessment of the vertebral fractures using SW-like images with CT-like contrast was found to be comparable to conventional CT. • sUTE imaging of the spine can help reduce examination times and radiation exposure.


Subject(s)
Fractures, Bone , Spinal Fractures , Humans , Water , Spine , Spinal Fractures/diagnostic imaging , Tomography, X-Ray Computed/methods , Magnetic Resonance Imaging/methods
5.
Eur Radiol ; 33(8): 5549-5556, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36806571

ABSTRACT

OBJECTIVES: To compare the visibility of anatomical structures and overall quality of the attenuation images obtained with a dark-field X-ray radiography prototype with those from a commercial radiography system. METHODS: Each of the 65 patients recruited for this study obtained a thorax radiograph at the prototype and a reference radiograph at the commercial system. Five radiologists independently assessed the visibility of anatomical structures, the level of motion artifacts, and the overall image quality of all attenuation images on a five-point scale, with 5 points being the highest rating. The average scores were compared between the two image types. The differences were evaluated using an area under the curve (AUC) based z-test with a significance level of p ≤ 0.05. To assess the variability among the images, the distributions of the average scores per image were compared between the systems. RESULTS: The overall image quality was rated high for both devices, 4.2 for the prototype and 4.6 for the commercial system. The rating scores varied only slightly between both image types, especially for structures relevant to lung assessment, where the images from the commercial system were graded slightly higher. The differences were statistically significant for all criteria except for the bronchial structures, the cardiophrenic recess, and the carina. CONCLUSIONS: The attenuation images acquired with the prototype were assigned a high diagnostic quality despite a lower resolution and the presence of motion artifacts. Thus, the attenuation-based radiographs from the prototype can be used for diagnosis, eliminating the need for an additional conventional radiograph. KEY POINTS: • Despite a low tube voltage (70 kVp) and comparably long acquisition time, the attenuation images from the dark-field chest radiography system achieved diagnostic quality for lung assessment. • Commercial chest radiographs obtained a mean rating score regarding their diagnostic quality of 4.6 out of 5, and the grating-based images had a slightly lower mean rating score of 4.2 out of 5. • The difference in rating scores for anatomical structures relevant to lung assessment is below 5%.


Subject(s)
Radiography, Thoracic , Thorax , Humans , X-Rays , Radiography, Thoracic/methods , Radiography , Lung/diagnostic imaging
6.
J Appl Clin Med Phys ; 19(1): 204-217, 2018 Jan.
Article in English | MEDLINE | ID: mdl-29266724

ABSTRACT

The performance of a recently introduced spectral computed tomography system based on a dual-layer detector has been investigated. A semi-anthropomorphic abdomen phantom for CT performance evaluation was imaged on the dual-layer spectral CT at different radiation exposure levels (CTDIvol of 10 mGy, 20 mGy and 30 mGy). The phantom was equipped with specific low-contrast and tissue-equivalent inserts including water-, adipose-, muscle-, liver-, bone-like materials and a variation in iodine concentrations. Additionally, the phantom size was varied using different extension rings to simulate different patient sizes. Contrast-to-noise (CNR) ratio over the range of available virtual mono-energetic images (VMI) and the quantitative accuracy of VMI Hounsfield Units (HU), effective-Z maps and iodine concentrations have been evaluated. Central and peripheral locations in the field-of-view have been examined. For all evaluated imaging tasks the results are within the calculated theoretical range of the tissue-equivalent inserts. Especially at low energies, the CNR in VMIs could be boosted by up to 330% with respect to conventional images using iDose/spectral reconstructions at level 0. The mean bias found in effective-Z maps and iodine concentrations averaged over all exposure levels and phantom sizes was 1.9% (eff. Z) and 3.4% (iodine). Only small variations were observed with increasing phantom size (+3%) while the bias was nearly independent of the exposure level (±0.2%). Therefore, dual-layer detector based CT offers high quantitative accuracy of spectral images over the complete field-of-view without any compromise in radiation dose or diagnostic image quality.


Subject(s)
Phantoms, Imaging , Quality Assurance, Health Care/standards , Radiation Protection/methods , Radiography, Dual-Energy Scanned Projection/instrumentation , Radiography, Dual-Energy Scanned Projection/methods , Tomography, X-Ray Computed/methods , Whole Body Imaging/methods , Humans , Image Processing, Computer-Assisted/methods , Radiation Dosage , Radiation Protection/instrumentation , Tomography, X-Ray Computed/instrumentation
7.
Cardiovasc Intervent Radiol ; 47(1): 109-114, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37989788

ABSTRACT

PURPOSE: Prompt endovascular treatment of patients with stroke due to intracranial Large Vessel Occlusion (LVO) is a major challenge in rural areas because neurointerventionalists are usually not available. As a result, treatment is delayed, and clinical outcomes are worse compared with patients primarily treated in comprehensive stroke centers (CSC). To address this problem, we present a concept in which interdisciplinary, on-site endovascular treatment is performed in a Primary Stroke Center (PSC) by a team of interventional neuroradiologists and cardiologists: the Rendez-Vous approach. METHODS: Thirty-five patients with LVO who underwent interdisciplinary thrombectomy on-site at the PSC as part of the Rendez-Vous concept were compared with 72 patients who were transferred from a PSCs to the CSC for thrombectomy when diagnosed with LVO in terms of temporal sequences and clinical outcomes. RESULTS: Patients treated on-site at the PSC as part of the Rendez-Vous approach were managed as successfully and without an increase in complication rates compared with patients treated secondarily at a CSC (91.7% successful interventions in Rendez-Vous vs. 87.3% in control group, p = 0.57). The time from diagnosis of LVO to groin puncture was reduced by mean 74.3 min with the Rendez-Vous concept (p < 0.01). Regarding the clinical outcome, a functionally independent status was achieved in 45.5% in the Rendez-Vous group and in 22.6% in the control group (p = 0.029). CONCLUSION: Thanks to interdisciplinary teamwork between cardiology and interventional neuroradiology in local PSCs, times to successful reperfusion can be reduced. This has a potentially positive impact on the clinical outcome of stroke patients.


Subject(s)
Brain Ischemia , Endovascular Procedures , Stroke , Humans , Stroke/diagnostic imaging , Stroke/surgery , Thrombectomy , Treatment Outcome , Endovascular Procedures/adverse effects , Brain Ischemia/etiology , Retrospective Studies
8.
Rofo ; 195(10): 883-889, 2023 10.
Article in English, German | MEDLINE | ID: mdl-37137320

ABSTRACT

BACKGROUND: Simulation training is a common method in many medical disciplines and is used to teach content knowledge, manual skills, and team skills without potential patient danger. METHODS: Simulation models and methods in interventional radiology are explained. Strengths and weaknesses of both simulators for non-vascular and vascular radiological interventions are highlighted and necessary future developments are addressed. RESULTS: Both custom-made and commercially available phantoms are available for non-vascular interventions. Interventions are performed under ultrasound guidance, with computed tomography assistance, or using mixed-reality methods. The wear and tear of physical phantoms can be countered with in-house production of 3D-printed models. Vascular interventions can be trained on silicone models or hightech simulators. Increasingly, patient-specific anatomies are replicated and simulated pre-intervention. The level of evidence of all procedures is low. CONCLUSION: Numerous simulation methods are available in interventional radiology. Training on silicone models and hightech simulators for vascular interventions has the potential to reduce procedural time. This is associated with reduced radiation dose for both patient and physician, which can also contribute to improved patient outcome, at least in endovascular stroke treatment. Although a higher level of evidence should be achieved, simulation training should already be integrated into the guidelines of the professional societies and accordingly into the curricula of the radiology departments. KEY POINTS: · There are numerous simulation methods for nonvascular and vascular radiologic interventions.. · Puncture models can be purchased commercially or made using 3D printing.. · Silicone models and hightech simulators allow patient-specific training.. · Simulation training reduces intervention time, benefiting both the patient and the physician.. · A higher level of evidence is possible via proof of reduced procedural times.. CITATION FORMAT: · Kreiser K, Sollmann N, Renz M. Importance and potential of simulation training in interventional radiology. Fortschr Röntgenstr 2023; 195: 883 - 889.


Subject(s)
Radiology, Interventional , Simulation Training , Humans , Radiology, Interventional/education , Curriculum , Tomography, X-Ray Computed , Silicones , Computer Simulation
9.
Unfallchirurgie (Heidelb) ; 125(11): 909-914, 2022 Nov.
Article in German | MEDLINE | ID: mdl-35024872

ABSTRACT

Atraumatic neck pain is a frequent reason for patients to attend the emergency department (ED). It remains a challenge for the treating physician to rule out possible life-threatening causes, such as a retropharyngeal abscess, meningitis or septic spondylodiscitis. Herein, we report the rare case of a patient suffering from retropharyngeal tendinitis. This rare cause of atraumatic neck pain is characterized by a significant decrease in the range of motion of the cervical spine, elevated infection parameters and pathognomonic MRI findings. In addition to presenting the rare case of retropharyngeal tendinitis, we also review selected previous case reports and thereby not only raise awareness for this rare disease but also suggest the best practice for treatment.


Subject(s)
Acute Pain , Calcinosis , Tendinopathy , Humans , Neck Pain/diagnosis , Diagnosis, Differential , Calcinosis/complications , Tendinopathy/complications , Cervical Vertebrae/diagnostic imaging , Acute Pain/complications , Chest Pain/complications
10.
Eur Radiol Exp ; 6(1): 9, 2022 03 01.
Article in English | MEDLINE | ID: mdl-35229244

ABSTRACT

BACKGROUND: Spirometry and conventional chest x-ray have limitations in investigating early emphysema, while computed tomography, the reference imaging method in this context, is not part of routine patient care due to its higher radiation dose. In this work, we investigated a novel low-dose imaging modality, dark-field chest x-ray, for the evaluation of emphysema in patients with alpha1-antitrypsin deficiency. METHODS: By exploiting wave properties of x-rays for contrast formation, dark-field chest x-ray visualises the structural integrity of the alveoli, represented by a high signal over the lungs in the dark-field image. We investigated four patients with alpha1-antitrypsin deficiency with a novel dark-field x-ray prototype and simultaneous conventional chest x-ray. The extent of pulmonary function impairment was assessed by pulmonary function measurement and regional emphysema distribution was compared with CT in one patient. RESULTS: We show that dark-field chest x-ray visualises the extent of pulmonary emphysema displaying severity and regional differences. Areas with low dark-field signal correlate with emphysematous changes detected by computed tomography using a threshold of -950 Hounsfield units. The airway parameters obtained by whole-body plethysmography and single breath diffusing capacity of the lungs for carbon monoxide demonstrated typical changes of advanced emphysema. CONCLUSIONS: Dark-field chest x-ray directly visualised the severity and regional distribution of pulmonary emphysema compared to conventional chest x-ray in patients with alpha1-antitrypsin deficiency. Due to the ultra-low radiation dose in comparison to computed tomography, dark-field chest x-ray could be beneficial for long-term follow-up in these patients.


Subject(s)
Emphysema , Pulmonary Emphysema , Emphysema/diagnostic imaging , Humans , Pulmonary Emphysema/diagnostic imaging , Radiography , Tomography, X-Ray Computed , X-Rays
11.
Eur J Radiol ; 142: 109843, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34274842

ABSTRACT

OBJECTIVES: To evaluate sparse sampling computed tomography (SpSCT) for detection of endoleak after endovascular aortic repair (EVAR) at different dose levels in terms of subjective image criteria and diagnostic accuracy. METHODS: Twenty clinically indicated computed tomography aortic angiography (CTA) scans were used to obtain simulated low-dose scans with 100%, 50%, 25%, 12.5% and 6.25% of the applicated clinical dose, resulting in five dose levels (DL). From full sampling (FS) data sets, every second (2-SpSCT) or fourth (4-SpSCT) projection was used to generate simulated sparse sampling scans. All examinations were evaluated by four blinded radiologists regarding subjective image criteria and diagnostic performance. RESULTS: Sensitivity was higher than 93% in 4-SpSCT at the 25% DL which is the same as with FS at full dose (100% DL). High accuracies and relative high AUC-values were obtained for 2- and 4-SpSCT down to the 12.5% DL, while for FS similar values were shown down to 25% DL only. Subjective image quality was significantly higher for 4-SpSCT compared to FS at each dose level. More than 90% of all cases were rated with a high or medium confidence for FS and 2-SpSCT at the 50% DL and for 4-SpSCT at the 25% DL. At DL 25% and 12.5%, more cases showed a high confidence using 2- and 4-SpSCT compared with FS. CONCLUSIONS: Via SpSCT, a dose reduction down to a 25% dose level (mean effective dose of 1.49 mSv in the current study) for CTA is possible while maintaining high image quality and full diagnostic confidence.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aortic Aneurysm, Abdominal/surgery , Aortography , Blood Vessel Prosthesis Implantation/adverse effects , Computed Tomography Angiography , Endoleak/diagnostic imaging , Endovascular Procedures/adverse effects , Humans , Retrospective Studies , Tomography, X-Ray Computed , Treatment Outcome
12.
Eur J Radiol ; 105: 195-203, 2018 Aug.
Article in English | MEDLINE | ID: mdl-30017279

ABSTRACT

INTRODUCTION: To evaluate the clinical potential of dual layer computed tomography (DLCT) for posterior fusions of the thoracic and lumbar spine and determine the optimal keV-settings for an improved overall image quality and effective reduction of metal artefacts affecting the implant inheriting vertebral body, the spinal canal, the paravertebral muscle and aorta. METHODS AND MATERIALS: Twenty patients with posterior thoracic and lumbar spinal fusion, who underwent a 120kVp- DLCT scan were included in this study. Two independent readers evaluated axial 0.9 mm slides with soft tissue and bone window settings. Image quality of the conventional scan was compared to virtual monoenergetic images (VMI) at 40, 60, 80, 100,120, 140, 160, 180 and 200 keV. Diagnostic image quality was assessed on a four point Likert-scale overall, as well as specifically for the implant inheriting bone, paravertebral muscle, spinal canal or aorta. The Hounsfield Units (HU) of the area with the most pronounced streak artefact as well as HU of a reference area containing fat and muscle were documented for each keV-setting and compared to the conventional image. SNR and CNR were calculated for each of the four anatomic areas. Statistical analysis was conducted for the total collective and separately for the thoracic and lumbar spine level. RESULTS: Starting from 80 keV qualitative analysis revealed significant improvement of overall image quality and benefit for each tissue separately compared to the conventional images (CI) (p-values in the range from <0.001 to 0.005). 180 keV was considered the optimal monoenergetic setting regarding the overall image quality. For the assessment of the implant inheriting bone, the spinal canal, paravertebral muscle and aorta 200, 180, 160 and 180 keV were rated to be the most sufficient. Our results reveal high inter-reader agreement for qualitative evaluations (intra-class correlation coefficients >0.927; p < 0.05). HU values within the most pronounced streak artefact increased significantly with higher keV (p < 0.001), while there was no significant alteration of HU within the reference area. A decrease in SNR and CNR for higher VMI was revealed by our results. CONCLUSION: VMIs of higher energies provide significant reduction of metallic artefacts from posterior spinal fusions. Dedicated keV settings to evaluate either the implant inheriting bone, the spinal canal,adjacent muscle or aorta - structures, which are frequently of particular interest after posterior spinal fusion - are recommended. In addition, an optimal keV for an improved overall image quality is proposed.


Subject(s)
Metals/chemistry , Radiographic Image Interpretation, Computer-Assisted , Spinal Fusion , Spine/diagnostic imaging , Tomography, X-Ray Computed , Adult , Aged , Aged, 80 and over , Artifacts , Female , Humans , Male , Middle Aged , Observer Variation , Prostheses and Implants , Reference Values , Reproducibility of Results , Signal-To-Noise Ratio , Spine/surgery , Tomography, X-Ray Computed/methods
13.
Eur J Radiol ; 102: 83-88, 2018 May.
Article in English | MEDLINE | ID: mdl-29685549

ABSTRACT

PURPOSE: Evaluation of the influence of iterative reconstruction, tube settings and patient habitus on the accuracy of iodine quantification with dual-layer spectral CT (DL-CT). MATERIAL AND METHODS: A CT abdomen phantom with different extension rings and four iodine inserts (1, 2, 5 and 10 mg/ml) was scanned on a DL-CT. The phantom was scanned with tube-voltages of 120 and 140 kVp and CTDIvol of 2.5, 5, 10 and 20 mGy. Reconstructions were performed for eight levels of iterative reconstruction (i0-i7). Diagnostic dose levels are classified depending on patient-size and radiation dose. RESULTS: Measurements of iodine concentration showed accurate and reliable results. Taking all CTDIvol-levels into account, the mean absolute percentage difference (MAPD) showed less accuracy for low CTDIvol-levels (2.5 mGy: 34.72%) than for high CTDIvol-levels (20 mGy: 5.89%). At diagnostic dose levels, accurate quantification of iodine was possible (MAPD 3.38%). Level of iterative reconstruction did not significantly influence iodine measurements. Iodine quantification worked more accurately at a tube voltage of 140 kVp. Phantom size had a considerable effect only at low-dose-levels; at diagnostic dose levels the effect of phantom size decreased (MAPD <5% for all phantom sizes). CONCLUSION: With DL-CT, even low iodine concentrations can be accurately quantified. Accuracies are higher when diagnostic radiation doses are employed.


Subject(s)
Abdomen/diagnostic imaging , Image Processing, Computer-Assisted/methods , Iodine , Phantoms, Imaging , Tomography, X-Ray Computed/methods , Algorithms , Humans , Radiation Dosage , Reproducibility of Results
14.
PLoS One ; 13(9): e0204565, 2018.
Article in English | MEDLINE | ID: mdl-30261038

ABSTRACT

Disorders of the lungs such as chronic obstructive pulmonary disease (COPD) are a major cause of chronic morbidity and mortality and the third leading cause of death in the world. The absence of sensitive diagnostic tests for early disease stages of COPD results in under-diagnosis of this treatable disease in an estimated 60-85% of the patients. In recent years a grating-based approach to X-ray dark-field contrast imaging has shown to be very sensitive for the detection and quantification of pulmonary emphysema in small animal models. However, translation of this technique to imaging systems suitable for humans remains challenging and has not yet been reported. In this manuscript, we present the first X-ray dark-field images of in-situ human lungs in a deceased body, demonstrating the feasibility of X-ray dark-field chest radiography on a human scale. Results were correlated with findings of computed tomography imaging and autopsy. The performance of the experimental radiography setup allows acquisition of multi-contrast chest X-ray images within clinical boundary conditions, including radiation dose. Upcoming clinical studies will have to demonstrate that this technology has the potential to improve early diagnosis of COPD and pulmonary diseases in general.


Subject(s)
Lung/diagnostic imaging , Radiography, Thoracic/methods , Autopsy , Cadaver , Early Diagnosis , Feasibility Studies , Female , Humans , Interferometry/instrumentation , Interferometry/methods , Lung Diseases/diagnostic imaging , Pulmonary Disease, Chronic Obstructive/diagnostic imaging , Radiographic Image Interpretation, Computer-Assisted , Radiography, Thoracic/instrumentation , Radiography, Thoracic/statistics & numerical data , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL