Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 24
Filter
1.
Europace ; 2023 May 11.
Article in English | MEDLINE | ID: mdl-37165671

ABSTRACT

BACKGROUND: Bipolar voltage (BV) electrograms for left atrial (LA) substrate characterization depend on catheter design and electrode configuration. AIMS: The aim of the study was to investigate the relationship between the BV amplitude (BVA) using four catheters with different electrode design and to identify their specific LA cutoffs for scar and healthy tissue. METHODS AND RESULTS: Consecutive high-resolution electroanatomic mapping was performed using a multipolar-minielectrode Orion catheter (Orion-map), a duo-decapolar circular mapping catheter (Lasso-map), and an irrigated focal ablation catheter with minielectrodes (Mifi-map). Virtual remapping using the Mifi-map was performed with a 4.5 mm tip-size electrode configuration (Nav-map). BVAs were compared in voxels of 3 × 3 × 3 mm3. The equivalent BVA cutoff for every catheter was calculated for established reference cutoff values of 0.1, 0.2, 0.5, 1.0, and 1.5 mV. We analyzed 25 patients (72% men, age 68 ± 15 years). For scar tissue, a 0.5 mV cutoff using the Nav corresponds to a lower cutoff of 0.35 mV for the Orion and of 0.48 mV for the Lasso. Accordingly, a 0.2 mV cutoff corresponds to a cutoff of 0.09 mV for the Orion and of 0.14 mV for the Lasso. For healthy tissue cutoff at 1.5 mV, a larger BVA cutoff for the small electrodes of the Orion and the Lasso was determined of 1.68 and 2.21 mV, respectively. CONCLUSION: When measuring LA BVA, significant differences were seen between focal, multielectrode, and minielectrode catheters. Adapted cutoffs for scar and healthy tissue are required for different catheters.

2.
J Pediatr Gastroenterol Nutr ; 73(3): 306-313, 2021 09 01.
Article in English | MEDLINE | ID: mdl-34091540

ABSTRACT

OBJECTIVE: The aim of the study was to evaluate the safety and use of the 3D-Transit system (Motilis SA, Lausanne, Switzerland) and to describe regional gastrointestinal transit times, segmental colonic transit times, and colonic movement patterns in healthy children. METHODS: Twenty-one healthy children (11 girls, median age 10.5 years, range 7-15 years) were included. For evaluation of gastrointestinal transit times and colonic movement patterns, we used the minimally invasive electromagnetic 3D-Transit system. A small electromagnetic capsule (21.5 mm × 8.3 mm) was ingested and tracked through the gastrointestinal tract by a body-worn detector. Regional gastrointestinal transit times were assessed as time between capsule passage of anatomical landmarks. Colonic movement patterns were described and classified based on capsule movement velocity, direction, and distance. RESULTS: One child could not swallow the capsule and 20 children completed the study without any discomfort or side-effects. Median whole gut transit time was 33.6 (range 10.7-80.5) hours, median gastric emptying time was 1.9 (range 0.1-22.1) hours, median small intestinal transit time was 4.9 (range 1.1-15.1) hours, and median colonic transit time was 26.4 (range 6.8-74.5) hours. Median ascending colon/cecum transit time was 9.7 (range 0.3-48.1) hours, median transverse colon transit time was 5.6 (range 0.0-11.6) hours, median descending colon transit time was 2.6 (range 0.01-22.3) hours, and median sigmoid colon/rectum transit time was 7.5 (range 0.1-31.6) hours. Colonic movement patterns among children corresponded to those previously described in healthy adults. CONCLUSIONS: The 3D-Transit system is a well-tolerated and minimally invasive method for assessment of gastrointestinal motility in children.


Subject(s)
Gastrointestinal Motility , Gastrointestinal Transit , Adolescent , Adult , Child , Colon , Electromagnetic Phenomena , Female , Gastrointestinal Tract , Humans
3.
Heart Rhythm ; 2024 May 16.
Article in English | MEDLINE | ID: mdl-38762133

ABSTRACT

BACKGROUND: Stroke remains one of the most serious complications in atrial fibrillation (AF) patients and has been linked to disturbances of the autonomic nervous system. OBJECTIVE: The purpose of this study was to test the hypothesis that impaired cardiac autonomic function might be associated with an enhanced stroke risk in AF patients. METHODS: A total of 1922 AF patients who were in either sinus rhythm (SR group; n = 1121) or AF (AF group; n = 801) on a 5-minute resting electrocardiographic (ECG) recording were enrolled in the study. Heart rate variability triangular index (HRVI), standard deviation of normal-to-normal intervals, root mean square root of successive differences of normal-to-normal intervals, mean heart rate, 5-minute total power, and power in the high-frequency, low-frequency, and very-low-frequency ranges were calculated. Cox regression models were constructed to examine the association of heart rate variability (HRV) parameters with the composite endpoint of stroke or systemic embolism. RESULTS: Mean age was 71 ± 8 years in the SR group and 75 ± 8 years in the AF group. Thirty-seven patients in the SR group (3.4%) and 60 patients in the AF group (8.0%) experienced a stroke or systemic embolism during follow-up of 5 years. In patients with SR, HRVI <15 was the strongest HRV parameter to be associated with stroke or systemic embolism (hazard ratio 3.04; 95% confidence interval 1.3-7.0; P = .009) after adjustment for multiple confounders. In the AF group, no HRV parameter was found to be associated with the composite endpoint. CONCLUSION: HRVI measured during SR on a single 5-minute ECG recording is independently associated with stroke or systemic embolism in AF patients. HRV analysis in SR may help to improve risk stratification in AF patients.

4.
Proc Natl Acad Sci U S A ; 107(18): 8201-6, 2010 May 04.
Article in English | MEDLINE | ID: mdl-20404209

ABSTRACT

Although other methods exist for monitoring gastrointestinal motility and contractility, this study exclusively provides direct and quantitative measurements of the forces experienced by an orally ingested pill. We report motive forces and torques calculated from real-time, in vivo measurements of the movement of a magnetic pill in the stomachs of fasted and fed humans. Three-dimensional net force and two-dimensional net torque vectors as a function of time data during gastric residence are evaluated using instantaneous translational and rotational position data. Additionally, the net force calculations described can be applied to high-resolution pill tracking acquired by any modality. The fraction of time pills experience ranges of forces and torques are analyzed and correlate with the physiological phases of gastric digestion. We also report the maximum forces and torques experienced in vivo by pills as a quantitative measure of the amount of force pills experience during the muscular contractions leading to gastric emptying. Results calculated from human data are compared with small and large animal models with a translational research focus. The reported magnitude and direction of gastric forces experienced by pills in healthy stomachs serves as a baseline for comparison with pathophysiological states. Of clinical significance, the directionality associated with force vector data may be useful in determining the muscle groups associated with gastrointestinal dysmotility. Additionally, the quantitative comparison between human and animal models improves insight into comparative gastric contractility that will aid rational pill design and provide a quantitative framework for interpreting gastroretentive oral formulation test results.


Subject(s)
Stomach/physiology , Torque , Animals , Dogs , Eating , Electromyography , Fasting , Humans , Imaging, Three-Dimensional , Rats
5.
J Interv Card Electrophysiol ; 66(9): 2047-2054, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37014482

ABSTRACT

BACKGROUND: Superimposition of farfield (FF) and nearfield (NF) bipolar voltage electrograms (BVE) complicates the confirmation of pulmonary vein (PV) isolation after catheter ablation of atrial fibrillation. Our aim was to develop an automatic algorithm based on a single-beat analysis to discriminate PV NF from atrial FF BVE from a circular mapping catheter during the cryoballoon PV isolation. METHODS: During freezing cycles in cryoablation PVI, local NF and distant FF signals were recorded, identified and labelled. BVEs were classified using four different machine learning algorithms based on four frequency domain (high-frequency power (PHF), low-frequency power (PLF), relative high power band, PHF ratio of neighbouring electrodes) and two time domain features (amplitude (Vmax), slew rate). The algorithm-based classification was compared to the true identification gained during the PVI and to a classification by cardiac electrophysiologists. RESULTS: We included 335 BVEs from 57 consecutive patients. Using a single feature, PHF with a cut-off at 150 Hz showed the best overall accuracy for classification (79.4%). By combining PHF with Vmax, overall accuracy was improved to 82.7% with a specificity of 89% and a sensitivity of 77%. The overall accuracy was highest for the right inferior PV (96.6%) and lowest for the left superior PV (76.9%). The algorithm showed comparable accuracy to the classification by the EP specialists. CONCLUSIONS: An automated farfield-nearfield discrimination based on two simple features from a single-beat BVE is feasible with a high specificity and comparable accuracy to the assessment by experienced cardiac electrophysiologists.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Humans , Electrocardiography , Pulmonary Veins/surgery , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Electrophysiologic Techniques, Cardiac , Algorithms , Treatment Outcome
6.
Cardiovasc Digit Health J ; 4(2): 41-47, 2023 Apr.
Article in English | MEDLINE | ID: mdl-37101946

ABSTRACT

Background: Emerging evidence indicates that a high atrial fibrillation (AF) burden is associated with adverse outcome. However, AF burden is not routinely measured in clinical practice. An artificial intelligence (AI)-based tool could facilitate the assessment of AF burden. Objective: We aimed to compare the assessment of AF burden performed manually by physicians with that measured by an AI-based tool. Methods: We analyzed 7-day Holter electrocardiogram (ECG) recordings of AF patients included in the prospective, multicenter Swiss-AF Burden cohort study. AF burden was defined as percentage of time in AF, and was assessed manually by physicians and by an AI-based tool (Cardiomatics, Cracow, Poland). We evaluated the agreement between both techniques by means of Pearson correlation coefficient, linear regression model, and Bland-Altman plot. Results: We assessed the AF burden in 100 Holter ECG recordings of 82 patients. We identified 53 Holter ECGs with 0% or 100% AF burden, where we found a 100% correlation. For the remaining 47 Holter ECGs with an AF burden between 0.01% and 81.53%, Pearson correlation coefficient was 0.998. The calibration intercept was -0.001 (95% CI -0.008; 0.006), and the calibration slope was 0.975 (95% CI 0.954; 0.995; multiple R2 0.995, residual standard error 0.017). Bland-Altman analysis resulted in a bias of -0.006 (95% limits of agreement -0.042 to 0.030). Conclusion: The assessment of AF burden with an AI-based tool provided very similar results compared to manual assessment. An AI-based tool may therefore be an accurate and efficient option for the assessment of AF burden.

7.
Int J Cardiol ; 356: 53-59, 2022 06 01.
Article in English | MEDLINE | ID: mdl-35278571

ABSTRACT

BACKGROUND: The effect of the ventricular repolarization heterogeneity has not been systematically assessed in patients with atrial fibrillation (AF). Aim of this study is to assess ventricular repolarization heterogeneity as predictor of cardiovascular (CV) death and/or other CV events in patients with AF. METHODS: From the multicenter prospective Swiss-AF (Swiss Atrial Fibrillation) Cohort Study, we enrolled 1711 patients who were in sinus rhythm (995) or AF (716). Resting ECG recordings of 5-min duration were obtained at baseline. Parameters assessing ventricular repolarization were computed (QTc, Tpeak-Tend, J-Tpeak and V-index). RESULTS: During AF, the V-index was found repeatable (no differences when computed over the whole recording, on the first 2.5-min and on the last 2.5-min segments). During a mean follow-up time of 2.6 ± 1.0 years, 90 patients died for CV reasons. In bivariate Cox regression analysis (adjusted for age only), the V-index was associated with an increased risk of CV death, both in the subgroup of patients in sinus rhythm (SR) as well as those in AF. In multivariate analysis adjusted for clinical risk factors and medications, both prolonged QTc and V-index were independently associated with an increased risk of CV death (QTc: hazard ratio [HR] 2.78, 95% CI 1.79-4.32, p < 0.001; V-index: HR 1.73, 95% CI 1.12-2.69, p = 0.014). CONCLUSIONS: QTc and V-index, measured in a single 5-min ECG recording, were independent predictors of CV death in a cohort of patients with AF and might be a valuable tool for further risk stratification to guide patient management. Clinical Trial Identifier Swiss-AF study: NCT02105844.


Subject(s)
Atrial Fibrillation , Atrial Fibrillation/diagnosis , Cohort Studies , Electrocardiography , Humans , Prospective Studies , Risk Factors
8.
Scand J Gastroenterol ; 46(7-8): 895-902, 2011 Jul.
Article in English | MEDLINE | ID: mdl-21623673

ABSTRACT

BACKGROUND: Diarrhea is part of the carcinoid syndrome and a significant clinical problem in neuroendocrine tumor (NET) patients. Somatostatin analog (SA) treatment usually alleviates carcinoid diarrhea, but little is known about the objective effects of SA on gastrointestinal transport. AIM: To compare gastrointestinal motility in healthy subjects and NET patients before and during SA treatment. METHODS: Twelve NET patients were studied before and during 4 weeks of SA treatment and were compared with 12 healthy controls. Radio-opaque markers were used for the assessment of total gastrointestinal transit time (GITT). Gastric and small intestinal (SI) transit patterns were described via the external tracking of a small magnetic pill ingested by the subjects. RESULTS: Compared with controls, NET patients had a significantly shorter GITT (0.7 days (0.5-1.5) vs. 1.9 days (1.0-2.3)), a shorter SI transit time (184 min (74-307) vs. 322 min (131-376)), and a faster SI velocity (2.16 cm/min (0.91-3.66) vs. 1.29 cm/min (0.76-2.60)) (all p < 0.05) but a similar gastric emptying time. SA treatment was followed by a reduction in bowel movements (five per day (3-12) vs. four per day (1-7; p < 0.02)) as well as an increase in GITT (1.4 days (0.5-2.2; p < 0.05)). Further, a trend was observed toward increased SI transit time (253 min (145-344; p = 0.08)). Gastric emptying time increased during SA treatment (19 min (4-200) vs. 179 min (5-389; p < 0.02)). Elevated chromogranin A (CgA), serotonin, and urinary 5-hydroxyindoleacetic acid (U-5HIAA) levels decreased during SA treatment. CONCLUSION: NET patients have faster than normal total GITT and SI transit times. SA treatment prolongs gastric emptying and GITT, thereby reducing the number of bowel movements.


Subject(s)
Antineoplastic Agents, Hormonal/pharmacology , Gastrointestinal Transit/drug effects , Intestinal Neoplasms/physiopathology , Neuroendocrine Tumors/physiopathology , Octreotide/analogs & derivatives , Adult , Aged , Aged, 80 and over , Antineoplastic Agents, Hormonal/therapeutic use , Biomarkers, Tumor/metabolism , Cecum/physiopathology , Chromogranin A/blood , Female , Gastric Emptying/drug effects , Humans , Hydroxyindoleacetic Acid/urine , Intestinal Neoplasms/blood , Intestinal Neoplasms/drug therapy , Intestinal Neoplasms/urine , Intestine, Small/physiopathology , Male , Middle Aged , Muscle Contraction/drug effects , Neuroendocrine Tumors/blood , Neuroendocrine Tumors/drug therapy , Neuroendocrine Tumors/urine , Octreotide/pharmacology , Octreotide/therapeutic use , Serotonin/blood , Statistics, Nonparametric , Time Factors
9.
Scand J Gastroenterol ; 46(10): 1187-93, 2011 Oct.
Article in English | MEDLINE | ID: mdl-21815862

ABSTRACT

BACKGROUND: Systemic sclerosis (SSc) is an autoimmune disease characterized by fibrosis and collagen deposits. Gastrointestinal symptoms of SSc, including abdominal pain, bloating and discomfort, are common but diffuse and their pathophysiology remains obscure. AIM: To investigate the pathophysiology of abdominal pain and discomfort in individuals with SSc. METHODS: A total of 15 individuals with SSc (13 women, median age 58 years), all suffering from diffuse abdominal symptoms, and 17 healthy volunteers (12 women, median age 52 years) were evaluated with the Motility Tracking System, MTS-1, measuring gastric emptying (GE) and velocity through the small intestine. SSc patients were also examined for bacterial overgrowth using the hydrogen breath test and with radiopaque markers to determine the total gastrointestinal transit time (GITT). RESULTS: Assessed with the MTS-1, the velocity through the proximal small intestine was significantly reduced in SSc patients (median 0.525 m/h, range 0.11-1.15) when compared to healthy subjects (median 0.91 m/h, range 0.51-1.74) (p = 0.02). Prolonged GE was found in 4 SSc patients (27%) but in none of the healthy volunteers (p = 0.04). Only 3 SSc patients (21%) had positive breath tests for small intestinal bacterial overgrowth. GITT was >3 days in 8 patients (53%). Slow small intestinal transit was associated with a prolonged GITT (p < 0.05). CONCLUSION: Velocity through the small intestine is significantly reduced in SSc patients with diffuse abdominal symptoms.


Subject(s)
Gastrointestinal Transit , Intestine, Small/physiopathology , Scleroderma, Systemic/physiopathology , Stomach/physiopathology , Abdominal Pain/etiology , Adult , Aged , Blind Loop Syndrome/complications , Blind Loop Syndrome/diagnosis , Breath Tests , Female , Gastric Emptying , Humans , Intestine, Small/diagnostic imaging , Magnets , Male , Middle Aged , Radionuclide Imaging , Scleroderma, Systemic/complications , Scleroderma, Systemic/diagnostic imaging , Statistics, Nonparametric , Stomach/diagnostic imaging
10.
BMC Gastroenterol ; 11: 145, 2011 Dec 29.
Article in English | MEDLINE | ID: mdl-22206545

ABSTRACT

BACKGROUND: Tracking an ingested magnet by the Magnet Tracking System MTS-1 (Motilis, Lausanne, Switzerland) is an easy and minimally-invasive method to assess gastrointestinal transit. The aim was to test the validity of MTS-1 for assessment of gastric transit time and small intestinal transit time, and to illustrate transit patterns detected by the system. METHODS: A small magnet was ingested and tracked by an external matrix of 16 magnetic field sensors (4 × 4) giving a position defined by 5 coordinates (position: x, y, z, and angle: θ, φ). Eight healthy subjects were each investigated three times: (1) with a small magnet mounted on a capsule endoscope (PillCam); (2) with the magnet alone and the small intestine in the fasting state; and (3) with the magnet alone and the small intestine in the postprandial state. RESULTS: Experiment (1) showed good agreement and no systematic differences between MTS-1 and capsule endoscopy when assessing gastric transit (median difference 1 min; range: 0-6 min) and small intestinal transit time (median difference 0.5 min; range: 0-52 min). Comparing experiments (1) and (2) there were no systematic differences in gastric transit or small intestinal transit when using the magnet-PillCam unit and the much smaller magnetic pill. In experiments (2) and (3), short bursts of very fast movements lasting less than 5% of the time accounted for more than half the distance covered during the first two hours in the small intestine, irrespective of whether the small intestine was in the fasting or postprandial state. The mean contraction frequency in the small intestine was significantly lower in the fasting state than in the postprandial state (9.90 min-1 vs. 10.53 min-1) (p = 0.03). CONCLUSION: MTS-1 is reliable for determination of gastric transit and small intestinal transit time. It is possible to distinguish between the mean contraction frequency of small intestine in the fasting state and in the postprandial state.


Subject(s)
Gastrointestinal Transit , Intestine, Small/physiology , Magnetometry , Adult , Capsule Endoscopes , Fasting , Female , Gastric Emptying , Humans , Magnets , Male , Middle Aged , Peristalsis , Postprandial Period , Statistics, Nonparametric
11.
J Neurogastroenterol Motil ; 27(3): 390-399, 2021 Jul 30.
Article in English | MEDLINE | ID: mdl-34210904

ABSTRACT

BACKGROUND/AIMS: Patients with diabetes mellitus (DM) often suffer from gastrointestinal (GI) symptoms, but these correlate poorly to established objective GI motility measures. Our aim is to perform a detailed evaluation of potential measures of gastric and small intestinal motility in patients with DM type 1 and severe GI symptoms. METHODS: Twenty patients with DM and 20 healthy controls (HCs) were included. GI motility was examined with a 3-dimensional-Transit capsule, while organ volumes were determined by CT scans. RESULTS: Patients with DM and HCs did not differ with regard to median gastric contraction frequency (DM: 3.0 contractions/minute [interquartile range {IQR}, 2.9-3.0]; HCs: 2.9 [IQR, 2.8-3.1]; P = 0.725), amplitude of gastric contractions (DM: 9 mm [IQR, 8-11]; HCs: 11 mm (IQR, 9-12); P = 0.151) or fasting volume of the stomach wall (DM: 149 cm3 [IQR, 112-187]; HCs: 132 cm3 [IQR, 107-154]; P = 0.121). Median gastric emptying time was prolonged in patients (DM: 3.3 hours [IQR, 2.6-4.6]; HCs: 2.4 hours [IQR, 1.8-2.7]; P = 0.002). No difference was found in small intestinal transit time (DM: 5 hours [IQR, 3.7-5.6]; HCs: 4.8 hours [IQR, 3.9-6.0]; P = 0.883). However, patients with DM had significantly larger volume of the small intestinal wall (DM: 623 cm3 [IQR, 487-766]; HCs: 478 cm3 [IQR, 393-589]; P = 0.003). Among patients, 13 (68%) had small intestinal wall volume and 9 (50%) had gastric emptying time above the upper 95% percentile of HCs. CONCLUSION: In our study, gastric emptying time and volume of the small intestinal wall appeared to be the best objective measures in patients with DM type 1 and symptoms and gastroenteropathy.

12.
Front Cardiovasc Med ; 8: 684461, 2021.
Article in English | MEDLINE | ID: mdl-34095266

ABSTRACT

Purpose: Silent brain infarcts (SBI) are frequently detected in patients with atrial fibrillation (AF), but it is unknown whether SBI are linked to autonomic dysfunction. We aimed to explore the association of autonomic dysfunction with SBI in AF patients. Methods: 1,358 AF patients without prior stroke or TIA underwent brain MRI and 5-min resting ECG. We divided our cohort into AF patients who presented in sinus rhythm (SR-group, n = 816) or AF (AF-group, n = 542). HRV triangular index (HRVI), standard deviation of normal-to-normal intervals, mean heart rate, root mean square root of successive differences of normal-to-normal intervals, 5-min total power and power in the low frequency, high frequency and very low frequency range were calculated. Primary outcome was presence of SBI in the SR group, defined as large non-cortical or cortical infarcts. Secondary outcomes were SBI volumes and topography. Results: Mean age was 72 ± 9 years, 27% were female. SBI were detected in 10.5% of the SR group and in 19.9% of the AF group (p < 0.001). HRVI <15 was the only HRV parameter associated with the presence of SBI after adjustment for clinical covariates in the SR group [odds ratio (OR) 1.67; 95% confidence interval (CI): 1.03-2.70; p = 0.037]. HRVI <15 was associated with larger brain infarct volumes [ß (95% CI) -0.47 (-0.84; -0.09), p = 0.016] in the SR group and was more frequently observed in patients with right- than left-hemispheric SBI (p = 0.017). Conclusion: Impaired HRVI is associated with SBI in AF patients. AF patients with autonomic dysfunction might undergo systematic brain MRI screening to initiate intensified medical treatment. Clinical Trials Gov Identifier: NCT02105844.

13.
Neurogastroenterol Motil ; 32(3): e13753, 2020 03.
Article in English | MEDLINE | ID: mdl-31721398

ABSTRACT

BACKGROUND: Opioid treatment often causes debilitating constipation. However, it is not well described how opioids affect colonic motility and whether opioid-induced constipation is due to either a decrease of powerful peristaltic contractions or "uncoordinated" peristalsis. The present study aims to investigate the effect of oxycodone on parameters of colonic motility and to determine whether motility is normalized by the opioid antagonist naloxegol. METHODS: In two randomized, double-blind crossover trials, oxycodone or placebo was administered to 25 healthy males (Trial A), while another 24 healthy males were administered oxycodone with naloxegol or placebo (Trial B). Colonic motility was assessed by tracking the progression of an electromagnetic capsule throughout the large intestine. Segmental colonic transit times and capsule movements were calculated using displacement distance and velocity. KEY RESULTS: In Trial A, colonic transit time increased during oxycodone treatment compared with placebo (39 vs 18 hours, P < .01). Displacement during long fast antegrade movements was shorter during oxycodone treatment than with placebo (10 vs 20 cm, P = .03). In Trial B, colonic transit time was faster during oxycodone + naloxegol than during oxycodone + placebo (40 vs 55 hours, P = .049), mainly caused by an increase of the percentwise fraction of distance covered by fast movements in the left colon (P = .001). CONCLUSION & INFERENCES: Oxycodone treatment impaired colonic motility, manifested as increased transit time, specifically decreased long fast antegrade movements, and addition of naloxegol improved motility dynamics. In humans, the increased transit time during opioid treatment is caused by a decrease in long fast movements rather than uncoordinated peristalsis.


Subject(s)
Analgesics, Opioid/adverse effects , Capsule Endoscopy/methods , Gastrointestinal Motility/drug effects , Morphinans/therapeutic use , Narcotic Antagonists/therapeutic use , Oxycodone/adverse effects , Polyethylene Glycols/therapeutic use , Adult , Cross-Over Studies , Double-Blind Method , Female , Gastrointestinal Transit/drug effects , Humans , Male , Middle Aged , Monitoring, Ambulatory/methods , Young Adult
14.
Neurogastroenterol Motil ; 32(12): e13948, 2020 12.
Article in English | MEDLINE | ID: mdl-32688448

ABSTRACT

BACKGROUND: Gastrointestinal (GI) symptoms are common in patients with diabetes mellitus (DM). The electromagnetic 3D-Transit system allows assessment of regional transit times and motility patterns throughout the GI tract. We aimed to compare GI transit times and detailed motility patterns of the colon in patients with DM and GI symptoms to those of healthy controls (HC). We further aimed to determine whether any abnormalities in motility were reversible by cholinergic stimulation. METHODS: We compared 18 patients with DM with 20 HC by means of the 3D-Transit system. Patients were studied before and during oral administration of 60 mg pyridostigmine. KEY RESULTS: Compared to HC, patients had prolonged gastric emptying (DM: 3.3 hours (interquartile range (IQR) 2.6-4.6); HC: 2.3 hours (IQR 1.7-2.7) (P < .01)), colonic transit time (DM: 52.6 hours (IQR 23.3-83.0); HC: 22.4 hours (IQR 18.9-43.6) (P = .02)), and whole gut transit time (DM: 69.4 hours (IQR 32.9-103.6); HC: 30.3 hours (IQR 25.2-49.9) (P < .01)). In addition, compared to HC, patients had prolonged transit time in the ascending colon (DM: 20.5 hours (IQR 11.0-44.0); HC: 8.0 hours (IQR 3.8-21.0) (P < .05)) and more slow retrograde movements in the colon (DM: 2 movements (IQR 1-4); HC: 1 movement (IQR 0-1) (P = .01)). In patients, pyridostigmine increased the number of bowel movements (P < .01) and reduced small intestine transit times (P < .05). CONCLUSIONS: Patients with DM and GI symptoms have longer than normal GI transit times. This is only partly reversible by pyridostigmine. The increased number of retrograde colonic movements in patients could potentially explain the abnormally long transit time in proximal colon.


Subject(s)
Colon/physiology , Diabetes Mellitus, Type 1/physiopathology , Electromagnetic Fields , Gastrointestinal Diseases/physiopathology , Gastrointestinal Motility/physiology , Wireless Technology , Adult , Diabetes Mellitus, Type 1/diagnosis , Female , Gastrointestinal Diseases/diagnosis , Gastrointestinal Transit/physiology , Humans , Male , Middle Aged , Wireless Technology/instrumentation
15.
Physiol Meas ; 41(12): 12TR01, 2020 12 31.
Article in English | MEDLINE | ID: mdl-33227727

ABSTRACT

Capsule-based methods for assessment of gastrointestinal (GI) motility have seen great improvements in recent decades. The most recent development is the electromagnetic Motilis 3D-Transit system (3D-Transit). The aim of this paper is to review and discuss the development and technical properties of magnetic tracking of GI motility. We performed a comprehensive literature review on magnetic tracking in GI research. The motility tracking system was the first capsule-based magnetic system to be used in GI motility research. However, the potential of the system was hampered by its stationary and hospitalizing nature. This led to the development of the electromagnetic Motilis 3D-Transit system. The 3D-Transit system is a portable system that allows for assessment of both whole gut and regional transit times and contraction patterns in a fully ambulatory setting in the patients' home environment with only minor restrictions on movements. The spatiotemporal resolution of 3D-Transit allows assessment of segmental colonic transit times and permits an analysis of gastric and colonic movements with a degree of detail unrivalled by other ambulatory methods, such as the wireless motility capsule. Recently, robust normative data on 3D-Transit have been published. This review provides a current perspective on the use of capsule-based magnetic tracking systems in GI research and how they represent a potentially valuable clinical resource for GI physicians and in GI research.


Subject(s)
Gastrointestinal Motility , Magnetics , Colon , Humans
16.
Neurogastroenterol Motil ; 32(6): e13829, 2020 06.
Article in English | MEDLINE | ID: mdl-32154975

ABSTRACT

BACKGROUND: The Motilis 3D-Transit system allows ambulatory description of transit patterns throughout the gastrointestinal tract and offers an alternative method for studying gastric motility. We aimed to establish normative values for gastric motility assessed with the method. METHOD: A total of 132 healthy volunteers ingested the 3D-Transit capsule for assessment of gastrointestinal transit times. Recordings from 125 subjects were used for definition of normative values. Forty-six subjects were studied on two consecutive days. Recordings were reanalyzed using newly developed software providing information on gastric emptying (GE) as well as contraction frequency and movement during gastric contractions. RESULTS: The median GE time was 2.7 hours (range 0.1-21.2). In 89% of subjects, the capsule passed the pylorus within a postingestion period of 6 hours. The median frequency of gastric contractions was 3.1 per minute (range 2.6-3.8). The frequency was higher in women (3.2, range 2.7-3.8) than in men (3.0, range 2.6-3.5) and increased with age (0.004 per year) (P < .05). The median amplitudes were 35° (range 4-85) when based on rotation of the capsule and 11 mm (range 6-31) when based on capsule change in position. The rotation amplitude was higher in women and decreased with increasing BMI (P < .05). The position amplitude was also higher in women and increased with the amount of calories in the test meal, but decreased with increasing BMI and age (P < .05). Day-to-day variation (P > .05) was considerable while inter-rater variability was small. CONCLUSION AND INFERENCES: We have established normative values for gastric motility assessed with the 3D-Transit system.


Subject(s)
Capsule Endoscopy/methods , Gastrointestinal Motility , Stomach/physiology , Adult , Capsule Endoscopy/instrumentation , Electromagnetic Phenomena , Female , Gastric Emptying , Gastrointestinal Transit , Humans , Male , Middle Aged
17.
Neurogastroenterol Motil ; 32(2): e13734, 2020 02.
Article in English | MEDLINE | ID: mdl-31565841

ABSTRACT

BACKGROUND: The 3D-Transit electromagnet tracking system (Motilis Medica, SA, Lausanne, Switzerland) is an emerging tool for the ambulatory assessment of gastrointestinal (GI) transit and motility. Using this tool, we aimed to derive normative values for region-specific colonic and GI transit times and to assess the influence of age, gender, and body mass index (BMI). METHODS: Regional and total colonic transit times (CTT), gastric emptying (GET), small intestinal (SITT), and whole gut (WGTT) transit times were extracted from 111 healthy volunteers from the United Kingdom and Denmark (58 female; median age: 40 years [range: 21-88]). The effects of age, gender, and BMI were assessed using standard statistical methods. KEY RESULTS: The ascending, transverse, descending, and rectosigmoid colon transit times accounted for 32%, 34%, 17%, and 17% of total CTT in females, and 33%, 25%, 14%, and 28% of total CTT in males. CTT and WGTT were seen to cluster at intervals separated by approximately 24 hours, providing further evidence of the non-continuous nature of these measurements. Increasing age was associated with longer CTT (P = .021), WGTT (P < .001) ascending (P = .004), transverse (P < .001), and total right (P < .001) colon transit times, but shorter rectosigmoid (P = .004) transit time. Female gender was significantly associated with longer transverse (P = .049) and descending (P < .001) colon transit times, but shorter rectosigmoid (P < .001) transit time. Increasing BMI was significantly associated with shorter WGTT (P = .012). CONCLUSIONS AND INFERENCES: For the first time, normative reference values for region-specific colonic transit have been presented. Age, gender, and BMI were seen to have an effect on transit times.


Subject(s)
Capsule Endoscopy/standards , Gastrointestinal Transit/physiology , Imaging, Three-Dimensional/methods , Adult , Age Factors , Aged , Aged, 80 and over , Body Mass Index , Capsule Endoscopes , Capsule Endoscopy/instrumentation , Female , Healthy Volunteers , Humans , Magnets , Male , Middle Aged , Reference Values , Sex Factors , Young Adult
18.
J Am Heart Assoc ; 9(15): e016075, 2020 08 04.
Article in English | MEDLINE | ID: mdl-32750290

ABSTRACT

Background Impaired heart rate variability (HRV) is associated with increased mortality in sinus rhythm. However, HRV has not been systematically assessed in patients with atrial fibrillation (AF). We hypothesized that parameters of HRV may be predictive of cardiovascular death in patients with AF. Methods and Results From the multicenter prospective Swiss-AF (Swiss Atrial Fibrillation) Cohort Study, we enrolled 1922 patients who were in sinus rhythm or AF. Resting ECG recordings of 5-minute duration were obtained at baseline. Standard parameters of HRV (HRV triangular index, SD of the normal-to-normal intervals, square root of the mean squared differences of successive normal-to-normal intervals and mean heart rate) were calculated. During follow-up, an end point committee adjudicated each cause of death. During a mean follow-up time of 2.6±1.0 years, 143 (7.4%) patients died; 92 deaths were attributable to cardiovascular reasons. In a Cox regression model including multiple covariates (age, sex, body mass index, smoking status, history of diabetes mellitus, history of hypertension, history of stroke/transient ischemic attack, history of myocardial infarction, antiarrhythmic drugs including ß blockers, oral anticoagulation), a decreased HRV index ≤ median (14.29), but not other HRV parameters, was associated with an increase in the risk of cardiovascular death (hazard ratio, 1.7; 95% CI, 1.1-2.6; P=0.01) and all-cause death (hazard ratio, 1.42; 95% CI, 1.02-1.98; P=0.04). Conclusions The HRV index measured in a single 5-minute ECG recording in a cohort of patients with AF is an independent predictor of cardiovascular mortality. HRV analysis in patients with AF might be a valuable tool for further risk stratification to guide patient management. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT02105844.


Subject(s)
Atrial Fibrillation/mortality , Cardiovascular Diseases/mortality , Heart Rate , Aged , Atrial Fibrillation/physiopathology , Cardiovascular Diseases/physiopathology , Electrocardiography , Electrocardiography, Ambulatory , Female , Heart Rate/physiology , Humans , Male , Predictive Value of Tests , Prospective Studies , Reproducibility of Results , Risk Assessment , Risk Factors
19.
Neurogastroenterol Motil ; 31(2): e13451, 2019 02.
Article in English | MEDLINE | ID: mdl-30129117

ABSTRACT

BACKGROUND: The Motilis 3D-Transit system tracks electromagnetic capsules as they traverse the gastrointestinal tract. The method is minimally invasive and ambulatory. Analysis has previously been limited to regional gut transit times, but new methods may allow detailed analysis of colonic motility. METHODS: Parameters of colonic motility were analyzed from 34 3D-Transit recordings performed in healthy volunteers (median age 28 years; 8 F). Characteristic propulsive velocities and lengths of movement were determined to quantify common movement patterns. Data from seven patients with severe chronic diarrhea were included for comparison. KEY RESULTS: Lack of capsule motion accounted for 82% (75%-87%) of total colonic transit time. Propulsive velocities were distributed with peaks at 0.5 cm/min (antegrade or retrograde) and 50 cm/min (antegrade). Based on velocity and length of propagation, five motor patterns were identified; (a) long fast antegrade, (b) fast antegrade, (c) slow antegrade, (d) slow retrograde, and (e) fast retrograde movements. Long fast antegrade movements were median 21 cm (10-96 cm). Capsule progression was faster during daytime than at night (5.9 cm/h vs 0.8 cm/h; P < 0.01). Colonic transit was faster in patients with chronic diarrhea than in healthy volunteers (5.4 h vs 18.2 h; P = 0.04), with higher capsule velocity (20.4 cm/h vs 4.4 cm/h; P < 0.01). CONCLUSIONS AND INFERENCES: The 3D-Transit system now allows detailed description of colonic motility and our results are supported by those previously suggested by manometry. It holds promise for future assessment of movement patterns to characterize different diseases and effects of treatment.


Subject(s)
Capsule Endoscopy/instrumentation , Capsule Endoscopy/methods , Gastrointestinal Motility/physiology , Monitoring, Ambulatory/instrumentation , Adult , Clinical Trials as Topic , Female , Gastrointestinal Transit/physiology , Humans , Male , Middle Aged
20.
JPEN J Parenter Enteral Nutr ; 29(4): 305-10, 2005.
Article in English | MEDLINE | ID: mdl-15961688

ABSTRACT

BACKGROUND: Fluoroscopic verification of nasogastric (NG) feeding tube placement is inconvenient and involves radiation exposure. We tested whether the position of an NG tube can be assessed reliably by a recently introduced magnet-tracking system. METHODS: A small permanent magnet was attached at the end of an NG tube and its position was monitored using an external sensor array connected to a computer. NG tube trajectory, spontaneous movements of the magnet, and its position relative to the lower esophageal sphincter (LES) and xiphisternum were assessed in 22 healthy subjects and compared with esophageal manometry. In 12 subjects, localization of the magnet was also compared with fluoroscopy. RESULTS: Magnet-tracking displayed NG tube tip movement reproducibly as it moved vertically in the esophagus and then laterally into the stomach. Compared with manometry, the accuracy and sensitivity of magnet tracking for localization of the NG tube tip, above or below the diaphragm, were 100%. Compared with fluoroscopy, the accuracy of NG tube localization by magnet tracking was 100%. With the magnet in the stomach, but not in the esophagus or LES, low amplitude displacements at a frequency of 3 per minute, consistent with gastric slow wave activity, were observed. CONCLUSIONS: Magnet tracking allows accurate, real-time, 3-dimensional localization of an NG tube with respect to anatomic landmarks. Recorded motor patterns are indicative of the position of the NG tube. Magnet tracking may be a useful tool for bedside placement of nasogastric and enteral feeding tubes.


Subject(s)
Electromagnetic Fields , Intubation, Gastrointestinal/instrumentation , Intubation, Gastrointestinal/methods , Adult , Equipment Design , Female , Fluoroscopy/instrumentation , Fluoroscopy/methods , Humans , Male , Manometry/instrumentation , Manometry/methods , Pilot Projects , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL