Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 35
Filter
Add more filters

Publication year range
1.
Philos Trans A Math Phys Eng Sci ; 379(2189): 20200011, 2021 Jan 25.
Article in English | MEDLINE | ID: mdl-33280561

ABSTRACT

Laser-direct drive (LDD), along with laser indirect (X-ray) drive (LID) and magnetic drive with pulsed power, is one of the three viable inertial confinement fusion approaches to achieving fusion ignition and gain in the laboratory. The LDD programme is primarily being executed at both the Omega Laser Facility at the Laboratory for Laser Energetics and at the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory. LDD research at Omega includes cryogenic implosions, fundamental physics including material properties, hydrodynamics and laser-plasma interaction physics. LDD research on the NIF is focused on energy coupling and laser-plasma interactions physics at ignition-scale plasmas. Limited implosions on the NIF in the 'polar-drive' configuration, where the irradiation geometry is configured for LID, are also a feature of LDD research. The ability to conduct research over a large range of energy, power and scale size using both Omega and the NIF is a major positive aspect of LDD research that reduces the risk in scaling from OMEGA to megajoule-class lasers. The paper will summarize the present status of LDD research and plans for the future with the goal of ultimately achieving a burning plasma in the laboratory. This article is part of a discussion meeting issue 'Prospects for high gain inertial fusion energy (part 2)'.

2.
Phys Rev Lett ; 125(25): 255002, 2020 Dec 18.
Article in English | MEDLINE | ID: mdl-33416398

ABSTRACT

The effectiveness of a dome-shaped wall covered by a thin gold foil (hollow wall) [M. Vandenboomgaerde et al., Phys. Plasmas 25, 012713 (2018)PHPAEN1070-664X10.1063/1.5008669] in holding back the high-Z plasma expansion in a gas-filled hohlraum is demonstrated for the first time in experiments reproducing the irradiation conditions of indirect drive at the ignition scale. The setup exploits a 1D geometry enabling record of the complete history of the gold expansion for 8 ns by imaging its emission in multiple x-ray energy ranges featuring either the absorption zones or the thermal emission regions. The measured expansion dynamics is well reproduced by numerical simulations. This novel wall design could now be tailored for the megajoule scale to enable the propagation of the inner beams up to the equator in low gas-filled hohlraum thus allowing the fine-tuning of the irradiation symmetry on the timescale required for ignition.

3.
Phys Rev Lett ; 108(12): 125003, 2012 Mar 23.
Article in English | MEDLINE | ID: mdl-22540590

ABSTRACT

A series of experiments to determine the optimum laser-beam radius by balancing the reduction of cross-beam energy transfer (CBET) with increased illumination nonuniformities shows that the hydrodynamic efficiency is increased by ∼35%, which leads to a factor of 2.6 increase in the neutron yield when the laser-spot size is reduced by 20%. Over this range, the absorption is measured to increase by 15%, resulting in a 17% increase in the implosion velocity and a 10% earlier bang time. When reducing the ratio of laser-spot size to a target radius below 0.8, the rms amplitudes of the nonuniformities imposed by the smaller laser spots are measured at a convergence ratio of 2.5 to exceed 8 µm and the neutron yield saturates despite increasing absorbed energy, implosion velocity, and decreasing bang time. The results agree well with hydrodynamic simulations that include both nonlocal and CBET models.

4.
Rev Sci Instrum ; 93(8): 083509, 2022 Aug 01.
Article in English | MEDLINE | ID: mdl-36050081

ABSTRACT

In this study, we present the absolute calibration of the conical crystal for the zinc spectrometer (ZSPEC), an x-ray spectrometer at the OMEGA laser facility at the Laboratory for Laser Energetics. The ZSPEC was originally designed to measure x-ray Thomson scattering using flat or cylindrically curved highly oriented pyrolytic graphite crystals centered around Zn He-alpha emission at 9 keV. To improve the useful spectral range and collection efficiency of the ZSPEC, a conical highly annealed pyrolytic graphite crystal was fabricated for the ZSPEC. The conically bent crystal in the Hall geometry produces a line focus perpendicular to the spectrometer axis, corresponding to the detector plane of electronic detectors at large scale laser facilities such as OMEGA, extending the useful range of the spectrometer to 7-11 keV. Using data collected using a microfocus Mo x-ray source, we determine important characteristics of ZSPEC such as the dispersion, spatial resolution, and absolute sensitivity of the instrument. A ray-trace model of ZSPEC provides another point of agreement in calculations of the ZSPEC dispersion and crystal response.

5.
Rev Sci Instrum ; 92(7): 073507, 2021 Jul 01.
Article in English | MEDLINE | ID: mdl-34340441

ABSTRACT

The very short burn time and small size of burning plasmas created at advanced laser-fusion facilities will require high-spatial-resolution imaging diagnostics with fast time resolution. These instruments will need to function in an environment of extremely large neutron fluxes that will cause conventional diagnostics to fail because of radiation damage and induced background levels. One solution to this challenge is to perform an ultrafast conversion of the x-ray signals into the optical regime before the neutrons are able to reach the detector and then to relay image the signal out of the chamber and into a shielded bunker, protected from the effects of these neutrons. With this goal in mind, the OMEGA laser was used to demonstrate high-temporal-resolution x-ray imaging by using an x-ray snout to image an imploding backlighter capsule onto a semiconductor. The semiconductor was simultaneously probed with the existing velocity interferometry system for any surface reflector (VISAR) diagnostic, which uses an optical streak camera and provided a one-dimensional image of the phase in the semiconductor as a function of time. The phase induced in the semiconductor was linearly proportional to the x-ray emission from the backlighter capsule. This approach would then allow a sacrificial semiconductor to be attached at the end of an optical train with the VISAR and optical streak camera placed in a shielded bunker to operate in a high neutron environment and obtain time-dependent one-dimensional x-ray images or time-dependent x-ray spectra from a burning plasma.

6.
Rev Sci Instrum ; 92(4): 043548, 2021 Apr 01.
Article in English | MEDLINE | ID: mdl-34243391

ABSTRACT

Hot-spot shape and electron temperature (Te) are key performance metrics used to assess the efficiency of converting shell kinetic energy into hot-spot thermal energy in inertial confinement fusion implosions. X-ray penumbral imaging offers a means to diagnose hot-spot shape and Te, where the latter can be used as a surrogate measure of the ion temperature (Ti) in sufficiently equilibrated hot spots. We have implemented a new x-ray penumbral imager on OMEGA. We demonstrate minimal line-of-sight variations in the inferred Te for a set of implosions. Furthermore, we demonstrate spatially resolved Te measurements with an average uncertainty of 10% with 6 µm spatial resolution.

7.
Rev Sci Instrum ; 92(2): 023503, 2021 Feb 01.
Article in English | MEDLINE | ID: mdl-33648107

ABSTRACT

Millimeter-sized CD foils fielded close (order mm) to inertial confinement fusion (ICF) implosions have been proposed as a game-changer for improving energy resolution and allowing time-resolution in neutron spectrum measurements using the magnetic recoil technique. This paper presents results from initial experiments testing this concept for direct drive ICF at the OMEGA Laser Facility. While the foils are shown to produce reasonable signals, inferred spectral broadening is seen to be high (∼5 keV) and signal levels are low (by ∼20%) compared to expectation. Before this type of foil is used for precision experiments, the foil mount must be improved, oxygen uptake in the foils must be better characterized, and impact of uncontrolled foil motion prior to detection must be investigated.

8.
Phys Rev Lett ; 104(3): 035004, 2010 Jan 22.
Article in English | MEDLINE | ID: mdl-20366653

ABSTRACT

Rugby-shaped hohlraums have been suggested as a way to enhance x-ray drive in the indirect drive approach to inertial confinement fusion. This Letter presents an experimental comparison of rugby-shaped and cylinder hohlraums used for D2 and D3He-filled capsules implosions on the Omega laser facility, demonstrating an increase of x-ray flux by 18% in rugby-shaped hohlraums. The highest yields to date for deuterium gas implosions in indirect drive on Omega (1.5x10{10} neutrons) were obtained, allowing for the first time the measurement of a DD burn history. Proton spectra measurements provide additional validation of the higher drive in rugby-shaped hohlraums.

9.
Rev Sci Instrum ; 91(2): 023511, 2020 Feb 01.
Article in English | MEDLINE | ID: mdl-32113451

ABSTRACT

A Talbot-Lau X-ray Deflectometer (TXD) was implemented in the OMEGA EP laser facility to characterize the evolution of an irradiated foil ablation front by mapping electron densities >1022 cm-3 by means of Moiré deflectometry. The experiment used a short-pulse laser (30-100 J, 10 ps) and a foil copper target as an x-ray backlighter source. In the first experimental tests performed to benchmark the diagnostic platform, grating survival was demonstrated and x-ray backlighter laser parameters that deliver Moiré images were described. The necessary modifications to accurately probe the ablation front through TXD using the EP-TXD diagnostic platform are discussed.

10.
Rev Sci Instrum ; 91(2): 023505, 2020 Feb 01.
Article in English | MEDLINE | ID: mdl-32113463

ABSTRACT

A method was developed with laser-irradiated Au planar foils to characterize the focal spot of UV laser beams on a target at full energy from soft x-ray emission. A pinhole camera with a back-thinned charge-coupled device detector and filtration with thin Be and Al foil filters provides images of the x-ray emission at photon energies <2 keV. This method requires a careful measurement of the relationship between the applied UV fluence and the x-ray signal, which can be described by a power-law dependence. The measured exponent γ ∼ 2 provides a dynamic range of ∼25 for the inferred UV fluence. UV fluence profiles of selected beams were measured for 100-ps and 1-ns laser pulses and were compared to directly measured profiles from an UV equivalent-target-plane diagnostic. The inferred spot size and super-Gaussian order from the x-ray technique agree within several percent with the values measured with the direct UV measurements.

11.
Rev Sci Instrum ; 90(3): 035103, 2019 Mar.
Article in English | MEDLINE | ID: mdl-30927813

ABSTRACT

Solid-state optical fiducial timing pulse generators provide a convenient and accurate method to include timing fiducials in a streak-camera image for time-base correction. Current commercially available vertical-cavity surface-emitting lasers (VCSELs) emitting in the visible range can be amplitude modulated up to 5 GHz. An optically passive method is utilized to interleave a time-delayed path of the 5-GHz pulsed light with itself, producing a 10-GHz pulsed fiducial, or comb. Comb pulse rates at 0.5, 1.0, and 2.5 GHz can also be selected. The instrument presented is a self-contained and portable generator with primary use for streak-camera temporal calibration. Applications can also be extended to many other optical timing needs. The VCSEL output is fiber optic coupled at a wavelength of 680 nm (visible red) with a nearly Gaussian pulse shape. The peak power of each ∼50-ps full width at half maximum (FWHM) comb pulse at 5-GHz operation, or picket, is approximately 5 mW. The low phase noise of the internal microwave modulation drive source provides low pulse to pulse jitter. An external reference frequency standard can be utilized to synchronize the output to external timing equipment. A selectable internal reference frequency crystal oscillator is incorporated for stand-alone operation.

12.
Rev Sci Instrum ; 89(10): 10G123, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399697

ABSTRACT

A new generation of fast-gated x-ray framing cameras have been developed that are capable of capturing multiple frames along a single line-of-sight with 30 ps temporal resolution. The instruments are constructed by integrating pulse-dilation electron imaging with burst mode hybrid-complimentary metal-oxide-semiconductor sensors. Two such instruments have been developed, characterized, and fielded at the National Ignition Facility and the OMEGA laser. These instruments are particularly suited for advanced x-ray imaging applications in Inertial Confinement Fusion and High energy density experiments. Here, we discuss the system architecture and the techniques required for tuning the instruments to achieve optimal performance. Characterization results are also presented along with planned future improvements to the design.

13.
Rev Sci Instrum ; 89(10): 10G117, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399700

ABSTRACT

The single-line-of-sight, time-resolved x-ray imager (SLOS-TRXI) on OMEGA is one of a new generation of fast-gated x-ray cameras comprising an electron pulse-dilation imager and a nanosecond-gated, burst-mode, hybrid complementary metal-oxide semiconductor sensor. SLOS-TRXI images the core of imploded cryogenic deuterium-tritium shells in inertial confinement fusion experiments in the ∼4- to 9-keV photon energy range with a pinhole imager onto a photocathode. The diagnostic is mounted on a fixed port almost perpendicular to a 16-channel, framing-camera-based, time-resolved Kirkpatrick-Baez microscope, providing a second time-gated line of sight for hot-spot imaging on OMEGA. SLOS-TRXI achieves ∼40-ps temporal resolution and better than 10-µm spatial resolution. Shots with neutron yields of up to 1 × 1014 were taken without observed neutron-induced background signal. The implosion images from SLOS-TRXI show the evolution of the stagnating core.

14.
Rev Sci Instrum ; 78(3): 034903, 2007 Mar.
Article in English | MEDLINE | ID: mdl-17411209

ABSTRACT

The temperature of laser-driven shock waves is of interest to inertial confinement fusion and high-energy-density physics. We report on a streaked optical pyrometer that measures the self-emission of laser-driven shocks simultaneously with a velocity interferometer system for any reflector (VISAR). Together these diagnostics are used to obtain the temporally and spatially resolved temperatures of approximately megabar shocks driven by the OMEGA laser. We provide a brief description of the diagnostic and how it is used with VISAR. Key spectral calibration results are discussed and important characteristics of the recording system are presented.

15.
Rev Sci Instrum ; 88(4): 043110, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28456236

ABSTRACT

We have built an absolutely calibrated, highly efficient, Bragg crystal spectrometer in von Hamos geometry. This zinc von Hamos spectrometer uses a crystal made from highly oriented pyrolytic graphite that is cylindrically bent along the non-dispersive axis. It is tuned to measure x-ray spectra in the 7-10 keV range and has been designed to be used on a Ten Inch Manipulator for the Omega and OmegaEP target chambers at the Laboratory for Laser Energetics in Rochester, USA. Significant shielding strategies and fluorescence mitigation have been implemented in addition to an imaging plate detector making it well suited for experiments in high-intensity environments. Here we present the design and absolute calibration as well as mosaicity and integrated reflectivity measurements.

16.
Rev Sci Instrum ; 87(5): 053501, 2016 05.
Article in English | MEDLINE | ID: mdl-27250417

ABSTRACT

A next-generation neutron temporal diagnostic (NTD) capable of recording high-quality data for the highest anticipated yield cryogenic deuterium-tritium (DT) implosion experiments was recently installed at the Omega Laser Facility. A high-quality measurement of the neutron production width is required to determine the hot-spot pressure achieved in inertial confinement fusion experiments-a key metric in assessing the quality of these implosions. The design of this NTD is based on a fast-rise-time plastic scintillator, which converts the neutron kinetic energy to 350- to 450-nm-wavelength light. The light from the scintillator inside the nose-cone assembly is relayed ∼16 m to a streak camera in a well-shielded location. An ∼200× reduction in neutron background was observed during the first high-yield DT cryogenic implosions compared to the current NTD installation on OMEGA. An impulse response of ∼40 ± 10 ps was measured in a dedicated experiment using hard x-rays from a planar target irradiated with a 10-ps short pulse from the OMEGA EP laser. The measured instrument response includes contributions from the scintillator rise time, optical relay, and streak camera.

17.
Rev Sci Instrum ; 87(11): 11D701, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27910508

ABSTRACT

A Particle X-ray Temporal Diagnostic (PXTD) has been implemented on OMEGA for simultaneous time-resolved measurements of several nuclear products as well as the x-ray continuum produced in High Energy Density Plasmas and Inertial Confinement Fusion implosions. The PXTD removes systematic timing uncertainties typically introduced by using multiple instruments, and it has been used to measure DD, DT, D3He, and T3He reaction histories and the emission history of the x-ray core continuum with relative timing uncertainties within ±10-20 ps. This enables, for the first time, accurate and simultaneous measurements of the x-ray emission histories, nuclear reaction histories, their time differences, and measurements of Ti(t) and Te(t) from which an assessment of multiple-ion-fluid effects, kinetic effects during the shock-burn phase, and ion-electron equilibration rates can be made.

18.
Rev Sci Instrum ; 85(11): 11D621, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25430197

ABSTRACT

We present a diagnostic technique used to spatially multiplex two x-ray radiographs of an object onto a detector along a single line-of-sight. This technique uses a thin, <2 µm, cosputtered backlighter target to simultaneously produce both Ni and Zn Heα emission. A Ni picket fence filter, 500 µm wide bars and troughs, is then placed in front of the detector to pass only the Ni Heα emission in the bar region and both energies in the trough region thereby spatially multiplexing the two radiographs on a single image. Initial experimental results testing the backlighter spectrum are presented along with simulated images showing the calculated radiographic images though the nickel picket fence filter which are used to measure the mix width in an accelerated nickel foam.

19.
Rev Sci Instrum ; 83(10): 10E107, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23126929

ABSTRACT

The streaked x-ray spectrometer (SXS) is used with streak cameras [D. H. Kalantar, P. M. Bell, R. L. Costa, B. A. Hammel, O. L. Landen, T. J. Orzechowski, J. D. Hares, and A. K. L. Dymoke-Bradshaw, in 22nd International Congress on High-Speed Photography and Photonics, edited by D. L. Paisley and A. M. Frank (SPIE, Bellingham, WA, 1997), Vol. 2869, p. 680] positioned with a ten-inch manipulator on OMEGA [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)] and OMEGA EP [L. J. Waxer et al., Presented at CLEO∕QELS 2008, San Jose, CA, 4-9 May 2008 (Paper JThB1)] for time-resolved, x-ray spectroscopy of laser-produced plasmas in the 1.4- to 20-keV photon-energy range. These experiments require measuring a portion of this photon-energy range to monitor a particular emission or absorption feature of interest. The SXS relies on a pinned mechanical reference system to create a discrete set of Bragg reflection geometries for a variety of crystals. A wide selection of spectral windows is achieved accurately and efficiently using this technique. It replaces the previous spectrometer designs that had a continuous Bragg angle adjustment and required a tedious alignment calibration procedure. The number of spectral windows needed for the SXS was determined by studying the spectral ranges selected by OMEGA users over the last decade. These selections are easily configured in the SXS using one of the 25 discrete Bragg reflection geometries and one of the six types of Bragg crystals, including two curved crystals.

20.
Rev Sci Instrum ; 83(10): 10E349, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23127006

ABSTRACT

A reflective optical transport system has been designed for the OMEGA Thomson-scattering diagnostic. A Schwarzschild objective that uses two concentric spherical mirrors coupled to a Pfund objective provides diffraction-limited imaging across all reflected wavelengths. This enables the operator to perform Thomson-scattering measurements of ultraviolet (0.263 µm) light scattered from electron plasma waves.

SELECTION OF CITATIONS
SEARCH DETAIL