Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 88
Filter
1.
Clin Oral Implants Res ; 34 Suppl 26: 86-103, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37750526

ABSTRACT

OBJECTIVE: The objectives of the study were to assess the survival, failure, and technical complication rates of implant-supported fixed dental prosthesis (iFDPs) with pontic or splinted crown (iSp C) designs in the posterior area and compare the influence of prosthetic materials and prosthetic design on the outcomes. METHODS: Electronic and manual searches were performed to identify randomized-, prospective-, and retrospective clinical trials with follow-up time of ≥12 months, evaluating the clinical outcomes of posterior iFDPs with pontic or iSp Cs. Survival and complication rates were analyzed using robust Poisson's regression models. RESULTS: Thirty-two studies reporting on 42 study arms were included in the present systematic review. The meta-analysis of the included studies indicated estimated 3-year survival rates of 98.3% (95%CI: 95.6-99.3%) for porcelain-fused-to-metal (PFM) iFDPs, 97.5% (95%CI: 95.5-98.7%) for veneered zirconia (Zr) iFDPs with pontic, 98.9% (95%CI: 96.8-99.6%) for monolithic or micro-veneered zirconia iFDPs with pontic, and 97.0% (95%CI: 84.8-99.9%) for lithium disilicate iFDPs with pontics. The survival rates for different material combination showed no statistically significant differences. Veneered restorations, overall, showed significantly (p < .01) higher ceramic fracture and chipping rates compared with monolithic restorations. Furthermore, there was no significant difference in survival rates (98.3% [95%CI: 95.6-99.3%] vs. 99.1% [95%CI: 97.6-99.7%]) and overall complication rates between PFM iFDPs with pontic and PFM iSp Cs. CONCLUSIONS: Based on the data identified by this systematic review, PFM, veneered Zr, and monolithic Zr iFDPs with pontic and iSp Cs showed similarly high short-term survival rates in the posterior area. Veneered restorations exhibit ceramic chipping more often than monolithic restorations, with the highest fracture rate reported for veneered Zr iFDPs.


Subject(s)
Dental Prosthesis Design , Dental Restoration Failure , Prospective Studies , Retrospective Studies , Dental Porcelain , Ceramics , Zirconium , Crowns , Dental Prosthesis, Implant-Supported
2.
Clin Oral Implants Res ; 34(2): 105-115, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36444693

ABSTRACT

OBJECTIVE: To investigate the fracture strength and potential phase transformation of an injection-molded two-piece zirconia implant restored with a zirconia abutment after loading and/or aging. METHODS: Thirty-two two-piece zirconia implants (4.0 mm diameter) restored with zirconia abutments were embedded according to ISO 14801 and divided into four groups (n = 8/group): Three groups were either exclusively hydrothermally treated (group HT; 85°C), dynamically loaded (group DL; 107 cycles; 98 N), or subjected to both treatments simultaneously (group DL/HT). One group remained untreated (group 0). A sample from each group was cross-sectioned and examined by scanning electron microscopy for possible crystal phase transformation. The remaining samples were then loaded to fracture in a static loading test. A one-way ANOVA was used for statistical analyses. RESULTS: During dynamic loading, three implants of group DL and six implants of group DL/HT fractured at a load of 98 N. The fracture strength of group DL/HT (108 ± 141 Ncm) was significantly reduced compared to the other groups (group 0: 342 ± 36 Ncm; HT: 363 ± 49 Ncm; DL: 264 ± 198 Ncm) (p < .05). Fractures from group 0 and HT occurred at both implant and abutment level, whereas implants from group DL and DL/HT fractured only at implant level. A shallow monoclinic transformation zone of approximately 2 µm was observed following hydrothermal treatment. CONCLUSIONS: Within the limitations of this study, it can be concluded that dynamic loading and the combination of loading and aging reduced the fracture strength of the implant abutment combination. Hydrothermal treatment caused a shallow transformation zone which had no influence on the fracture strength.


Subject(s)
Dental Implants , Flexural Strength , Dental Implant-Abutment Design , Materials Testing , Titanium/chemistry , Zirconium/chemistry , Dental Stress Analysis , Dental Abutments , Dental Restoration Failure
3.
Clin Oral Investig ; 27(10): 5875-5886, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37581766

ABSTRACT

OBJECTIVES: To assess clinical, radiological and esthetic outcomes of restorations supported by root-analogue implants (RAIs) or roots of severely damaged teeth after forced orthodontic extrusion (FOE). MATERIALS AND METHODS: Clinical data regarding milled one-piece (titanium/zirconia roots and zirconia abutments) RAIs (REPLICATE™ System) and FOE were recorded and retrospectively evaluated for 40 patients by two investigators. Strict inclusion and exclusion criteria were applied. Functional and esthetic outcomes were assessed for n = 20 pre-molars and n = 20 anterior teeth via comparison of radiographic and digital images applying the novel Functional Implant Prosthodontic Score (FIPS). Krippendorff's alpha coefficient was calculated to assess inter-rater reliability. Mann-Whitney-U-Test was used to compare the assessed parameters. Level of significance was set to p < 0.05. RESULTS: After a mean observation period of 18.4 ± 5.7 months for restorations supported by RAIs and 43.9 ± 16.4 months for restorations after FOE, mean FIPS scores were 9.2/8.8 ± 1.1/1.2 (RAIs) and 7.4/7.7 ± 1.3/1.5 (FOE), respectively. Krippendorff's alpha coefficients did not reveal unacceptable inter-rater reliabilities regarding the investigators and applicability of FIPS. Significant differences were documented when comparing restorations after FOE or supported by RAIs regarding bone loss (p < 0.01), presence of papillae (p < 0.05) and quality and quantity of mucosa (p < 0.02) in favor of FOE. CONCLUSIONS: Within the main limitations of sample size and the retrospective study design, both concepts seem to provide clinically acceptable results. CLINICAL RELEVANCE: Bone- and tissue-preserving characteristics regarding the concept of FOE are promising. It could be applicable for socket preservation and subsequent conventional implant placements in an adapted workflow.

4.
Clin Oral Implants Res ; 33(10): 1021-1029, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35861131

ABSTRACT

OBJECTIVE: To evaluate the impact of reducing the radiographic field of view (FOV) on the trueness and precision of the alignment between cone beam computed tomography (CBCT) and intraoral scanning data for implant planning. MATERIALS AND METHODS: Fifteen participants presenting with one of three clinical scenarios: single tooth loss (ST, n = 5), multiple missing teeth (MT, n = 5) and presence of radiographic artifacts (AR, n = 5) were included. CBCT volumes covering the full arch (FA) were reduced to the quadrant (Q) or the adjacent tooth/teeth (A). Two operators, an expert (exp) in virtual implant planning and an inexperienced clinician, performed multiple superimpositions, with FA-exp serving as a reference. The deviations were calculated at the implant apex and shoulder levels. Thereafter, linear mixed models were adapted to investigate the influence of FOV on discrepancies. RESULTS: Evaluation of trueness compared to FA-exp resulted in the largest mean (AR-A: 0.10 ± 0.33 mm) and single maximum discrepancy (AR-Q: 1.44 mm) in the presence of artifacts. Furthermore, for the ST group, the largest mean error (-0.06 ± 0.2 mm, shoulder) was calculated with the FA-FOV, while for MT, with the intermediate volume (-0.07 ± 0.24 mm, Q). In terms of precision, the mean SD intervals were ≤0.25 mm (A-exp). Precision was influenced by FOV volume (FA < Q < A) but not by operator expertise. CONCLUSIONS: For single posterior missing teeth, an extended FOV does not improve registration accuracy. However, in the presence of artifacts or multiple missing posterior teeth, caution is recommended when reducing FOV.


Subject(s)
Dental Implants , Tooth , Cone-Beam Computed Tomography/methods , Humans , Imaging, Three-Dimensional , Pilot Projects , Retrospective Studies
5.
Clin Oral Investig ; 26(1): 849-861, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34241707

ABSTRACT

OBJECTIVES: To evaluate long-term survival and success rates of conventionally cemented partial-coverage crowns (PCCs) manufactured from high noble metal alloys (hn). MATERIAL AND METHODS: Restoration-, periodontal- and tooth-related criteria on patients, restored with a single or multiple conventionally cemented hnPCCs in a private dental office were collected from existing patient records. With regard to semi-annual follow-ups, data of the most recent clinical evaluations were considered. Kaplan-Meier and log-rank tests were used for statistical analyses. Level of significance was set at p ≤ .05. RESULTS: Between 09/1983 and 09/2009, 1325 hnPCCs were conventionally cemented on 1325 teeth in 266 patients (mean age: 44.5 ± 10.7 years). Due to various reasons, 81 hnPCCs showed complications, documenting a success rate of 93.9% after a mean observation period of 18.8 ± 5.7 years. Of these, additional 14 restorations were counted as survival, resulting in a survival rate of 94.9%. Most frequent complications were periodontal issues (n = 29, 35.8%). Significantly higher success rates were documented for hnPCCs of patients aged between 37 and 51 years (p = .012). CONCLUSION: Partial-coverage crowns from high noble metal alloys showed excellent survival and success rates after a mean observation period of 18.8 ± 5.7 years. Higher patient age was one of the risk factors. CLINICAL RELEVANCE: According to the results of this study, hnPCCs still represent an excellent therapeutic option-even in modern dentistry.


Subject(s)
Dental Porcelain , Metal Ceramic Alloys , Adult , Alloys , Crowns , Dental Restoration Failure , Humans , Middle Aged , Retrospective Studies
6.
Int J Comput Dent ; 25(4): 349-359, 2022 Nov 25.
Article in English | MEDLINE | ID: mdl-35072424

ABSTRACT

PURPOSE: Creating wax-ups of missing teeth for backward planning in implant surgery is a complex and time-consuming process. To facilitate implant-planning procedures, the automatic generation of a virtual wax-up would be useful. In the present study, the reconstruction of missing teeth in partially edentulous patients was performed automatically using newly developed software. The accuracy was investigated in order to test its clinical applicability. MATERIALS AND METHODS: This study presents a new method for creating an automatic virtual wax-up, which could serve as a basic tool in modern implant-planning procedures. First, a statistical shape model (SSM) based on 76 maxillary and mandibular arch scans from dentally healthy individuals was generated. Then, artificially generated tooth gaps were reconstructed. The accuracy of the workflow was evaluated on a separate testing sample of 10 individuals with artificially created tooth gaps given as a median deviation, in millimeters. Scans of three clinical cases with partial edentulism were equally reconstructed using the SSM and compared with the final prosthodontic work. RESULTS: The reconstruction of the artificial tooth gaps could be performed with the following median reconstruction accuracy: gap 21 with 0.15 mm; gap 27 with 0.20 mm; gap 34 with 0.22 mm: gap 36 with 0.22 mm; gaps 12 to 22 with 0.22 mm; gaps 34 to 36 with 0.22 mm. A scenario for an almost edentulous mandible with all teeth missing except teeth 33 and 43 could be reconstructed with a median reconstruction accuracy of 0.37 mm. The median tooth gap deviation of the SSM-based reconstruction in clinical cases differed from the final inserted prosthodontic teeth by 0.49 to 0.86 mm in median. CONCLUSION: A first feasibility of creating virtual wax-ups using an SSM could be shown. Artificially generated tooth gaps could be reconstructed close to the original with the proposed workflow. In the clinical cases, the SSM proposes an anatomical reconstruction, which does not yet consider prosthodontic aspects. To obtain clinical use, contact with antagonist teeth must be considered and more training data must be implemented. However, the presented method offers a fast and viable way for the approximate placement of missing crowns. This could be used in a digital planning workflow when implant position must be determined. (Int J Comput Dent 2022;25(4):349-0; doi: 10.3290/j.ijcd.b2599407).


Subject(s)
Dental Implants , Mouth, Edentulous , Humans , Prosthodontics , Models, Statistical , Crowns
7.
Clin Oral Implants Res ; 32(4): 470-486, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33501694

ABSTRACT

OBJECTIVE: To assess clinical and patient-reported outcomes of implant-prosthetic rehabilitations in patients with a history of head-neck cancer (HNC), treated with tumor resection without (TR) or with adjuvant radiotherapy (TR/RT). A healthy cohort rehabilitated with the same reconstructive protocols served as control group (C). MATERIALS AND METHODS: A total of 28 women and 29 men were considered in the present retrospective study. Participants received 322 implants, finally supporting 79 prosthetic reconstructions. Primary outcome was the assessment of implant and prosthetic survival rates. Furthermore peri-implant soft tissue parameters (attached peri-implant mucosa, AM; modified bleeding and plaque indices, mBI/mPI; probing depth, PD) and prosthetic technical complications were documented. Patient-reported outcome measures (PROMs) by means of visual analog scales (VAS) and the Oral Health Impact Profile German 14 form (OHIP G14) were collected. For statistical purposes Chi-square and Mann-Whitney-U-Test were adapted. RESULTS: After a mean follow-up of 81.2 ± 50.3 months, implant survival rate was 98.1% (HNC-TR), 98.2% (HNC-TR/RT) and 100.0% (C), respectively (four implants failed in the HNC groups). HNC-TR/RT showed significant higher mPI and mBI compared to C. Within HNC-TR/RT, vestibuloplasty significantly reduced mBI and PD values. No failures occurred at the prosthetic level. Overall, higher VAS scores were reported for bar- compared with Locator-retained prostheses. Furthermore, increased OHIP G14 values resulted for HNC-TR/RT. CONCLUSIONS: High survival rates on implant and prosthetic level were observed. The use of soft tissue grafts resulted in stabilization of the peri-implant mucosa in irradiated patients. In terms of retention and chewing ability, participants preferred bars over Locator attachments.


Subject(s)
Dental Implants , Head and Neck Neoplasms , Jaw, Edentulous , Dental Prosthesis, Implant-Supported , Denture Retention , Denture, Overlay , Female , Head and Neck Neoplasms/radiotherapy , Head and Neck Neoplasms/surgery , Humans , Male , Retrospective Studies
8.
Clin Oral Implants Res ; 32(11): 1288-1298, 2021 Nov.
Article in English | MEDLINE | ID: mdl-34352139

ABSTRACT

OBJECTIVE: To evaluate the influence of artificial aging on the transformation propagation and fracture resistance of zirconia implants. METHODS: One-piece (with integrated implant abutment, 1P; regular diameter [4.1mm]; n = 16) and two-piece (with separate implant abutment, 2P; wide diameter [5 mm]; n = 16) zirconia implants were embedded according to ISO 14801. A two-piece titanium-zirconium implant (Ti-Zr; 4.1 mm diameter) served as a control (n = 16). One subgroup (n = 8) of each system was simultaneously dynamically loaded (107 cycles; 98N) and hydrothermally aged (85°C, 58 days), while the other subgroup (n = 8) remained untreated. Finally, specimens were statically loaded to fracture. Potential crystal phase transformation was examined at cross sections using scanning electron microscopy (SEM). A multivariate linear regression model was applied for statistical analyses. RESULTS: The fracture resistance of 1P (1,117 [SD = 38] N; loaded/aged: 1,009 [60] N), 2P (850 [36] N; loaded/aged: 799 [84] N), and Ti-Zr implants (1,338 [205] N; loaded/aged: 1,319 [247] N) was not affected significantly by loading/aging (p = .171). However, when comparing the systems, they revealed significant differences independent of loading/aging (p ≤ .001). Regarding the crystal structure, a transformation zone was observed in SEM images of 1P only after aging, while 2P showed a transformation zone even before aging. After hydrothermal treatment, an increase of this monoclinic layer was observed in both systems. CONCLUSIONS: The Ti-Zr control implant showed higher fracture resistance compared to both zirconia implants. Loading/aging had no significant impact on the fracture resistance of both zirconia implants. The wide-body 2P zirconia implant was weaker than the regular body 1P implant.


Subject(s)
Dental Implants , Zirconium , Dental Abutments , Dental Implant-Abutment Design , Dental Restoration Failure , Dental Stress Analysis , Materials Testing , Titanium
9.
J Prosthet Dent ; 125(1): 103-110, 2021 Jan.
Article in English | MEDLINE | ID: mdl-32063385

ABSTRACT

STATEMENT OF PROBLEM: Reliable studies comparing the accuracy of complete-arch casts from 3D printers are scarce. PURPOSE: The purpose of this in vitro study was to investigate the accuracy of casts printed by using various extrusion- and photopolymerization-based printers. MATERIAL AND METHODS: A master file was sent to 5 printer manufacturers and distributors to print 37 identical casts. This file consisted of a standardized data set of a maxillary cast in standard tessellation language (STL) format comprising 5 reference points for the measurement of 3 distances that served as reference for all measurements: intermolar width (IMW), intercanine width (ICW), and dental arch length (AL). The digital measurement of the master file obtained by using a surveying software program (Convince Premium 2012) was used as the control. Two extrusion-based (M2 and Ultimaker 2+) and 3 photopolymerization-based printers (Form 2, Asiga MAX UV, and myrev140) were compared. The casts were measured by using a multisensory coordinate measuring machine (O-Inspect 422). The values were then compared with those of the master file. The Mann-Whitney U test and Levene tests were used to determine significant differences in the trueness and precision (accuracy) of the measured distances. RESULTS: The deviations from the master file at all 3 distances for the included printers ranged between 12 µm and 240 µm (trueness), with an interquartile range (IQR) between 17 µm and 388 µm (precision). Asiga MAX UV displayed the highest accuracy, considering all the distances, and Ultimaker 2+ demonstrated comparable accuracy for shorter distances (IMW and ICW). Although myrev140 operated with high precision, it displayed high deviations from the master file. Similarly, although Form 2 exhibited high IQR, it did not deviate significantly from the master file in the longest range (AL). M2 performed consistently. CONCLUSIONS: Both extrusion-based and photopolymerization-based printers were accurate. In general, inexpensive printers were no less accurate than more expensive ones.


Subject(s)
Models, Dental , Printing, Three-Dimensional , Computer-Aided Design , Dental Impression Technique , Imaging, Three-Dimensional , Maxilla , Software
10.
J Prosthet Dent ; 125(6): 924-931, 2021 Jun.
Article in English | MEDLINE | ID: mdl-32487348

ABSTRACT

STATEMENT OF PROBLEM: Intraoral scanners (IOSs) are based on light-optical imaging methods. However, little is known about whether the ambient light in dental practices influences the accuracy and scanning time of the IOS. PURPOSE: The purpose of this in vitro study was to investigate the influence of different illuminations on the accuracy of 4-unit and complete-arch scans of 6 IOSs. In addition, the required scanning time was evaluated. MATERIAL AND METHODS: A reference structure was attached to the first premolars (P) and second molars (M) in both quadrants (L/R) of a maxillary model. The resulting measured distances were M1-P1, M2-P2, P1-P2, and M1-M2. The investigation included 6 IOSs: TRIOS 3 (TRI), Cerec Omnicam (OC), iTero Element (ITE), CS 3600 (CS), Planmeca Emerald (EME), and GC Aadva (AAD). With each IOS, 17 scans at different illuminances (100, 500, 1000, and 5000 lux) were performed (N = 408). The precision and trueness for all distances were determined, and the scanning time was recorded. For statistical analyses, the Levene tests (precision) and 1-way analysis of variance with the post hoc Tukey honestly significant difference and Games-Howell tests (trueness) were calculated. RESULTS: Illuminance significantly influenced the trueness of 4-unit scans for OC, EME, and AAD. TRI, OC, ITE, and CS demonstrated comparable results. AAD (>96 ±22 µm; 1000 lux) and EME (>248 ±88 µm; 500 lux) revealed greater deviations. For complete-arch scans, illuminance did not influence TRI and AAD, but significant variations were detected for ITE, CS, EME, and AAD. The least deviations were achieved with TRI and OC. The scanning time was extended for all IOSs except ITE at more than 500 lux. The shortest scanning times with OC and EME were recorded at 100 lux; with TRI, CS, and AAD at 500 lux; and with ITE at both 100 and 5000 lux. At all illuminances, the fastest scans were obtained with TRI. CONCLUSIONS: Ambient light was found to influence the accuracy and scanning time of IOSs. This influence varies depending on the device. For 4-unit scans, the effect was not clinically relevant, but for complete-arch scans, accuracy and scanning time can be improved with appropriate lighting.


Subject(s)
Dental Impression Technique , Models, Dental , Computer-Aided Design , Dental Arch , Imaging, Three-Dimensional
11.
Clin Oral Implants Res ; 31(5): 452-462, 2020 May.
Article in English | MEDLINE | ID: mdl-31981374

ABSTRACT

AIM: To evaluate the clinical and radiological outcomes of one-piece zirconia implants restored with single crowns (SCs) or fixed dental prostheses (FDPs) over an observation period of 5 years in function. MATERIALS AND METHODS: In a prospective cohort investigation with two investigational centers, one-piece zirconia implants were placed in anterior and posterior sites. After a healing period of at least 2 months in the mandible and 4 months in the maxilla with immediate provisional reconstructions, the final all-ceramic SCs or three-unit FDPs were cemented. Patients were followed for 5 years. Clinical parameters and radiological measurements of the implants and the neighboring teeth were assessed. For the statistical analysis, linear mixed models were applied. RESULTS: A total of 71 implants were placed in 60 patients. Sixty-three implants in 53 patients could be evaluated at the 5-year follow-up. Six patients with a total of seven implants were counted as dropouts. One implant did not achieve adequate osseointegration and had to be removed 5 weeks after implantation. The 5-year survival rate was calculated as 98.4% (95% CI 91.6, 99.9). The mean overall marginal bone loss from implant placement to the 5-year follow-up was 0.7 ± 0.6 mm. After an initial mean marginal loss before loading the implants (0.7 mm), no further statistically significant change in marginal bone level (p = .458) could be observed. CONCLUSION: The investigated one-piece zirconia implant showed a high survival rate, very stable marginal bone, and mucosal margin levels after 5 years in function. Therefore, it can be considered safe and reliable for the reconstruction of implant-supported SCs or FDPs over a mid-term period.


Subject(s)
Dental Implants , Dental Prosthesis, Implant-Supported , Crowns , Dental Prosthesis Design , Dental Restoration Failure , Denture, Partial, Fixed , Humans , Prospective Studies , Zirconium
12.
Molecules ; 25(24)2020 Dec 15.
Article in English | MEDLINE | ID: mdl-33333753

ABSTRACT

A polyolefin with certified biocompatibility according to USP class VI was used by our group as feedstock for filament-based 3D printing to meet the highest medical standards in order to print personal protective equipment for our university hospital during the ongoing pandemic. Besides the chemical resistance and durability, as well as the ability to withstand steam sterilization, this polypropylene (PP) copolymer is characterized by its high purity, as achieved by highly efficient and selective catalytic polymerization. As the PP copolymer is suited to be printed with all common printers in fused filament fabrication (FFF), it offers an eco-friendly cost-benefit ratio, even for large-scale production. In addition, a digital workflow was established focusing on common desktop FFF printers in the medical sector. It comprises the simulation-based optimization of personalized print objects, considering the inherent material properties such as warping tendency, through to validation of the process chain by 3D scanning, sterilization, and biocompatibility analysis of the printed part. This combination of digital data processing and 3D printing with a sustainable and medically certified material showed great promise in establishing decentralized additive manufacturing in everyday hospital life to meet peaks in demand, supply bottlenecks, and enhanced personalized patient treatment.


Subject(s)
Polyenes/chemistry , Polymers/chemistry , Humans , Personal Protective Equipment , Polypropylenes/chemistry , Printing, Three-Dimensional
13.
Int J Comput Dent ; 23(1): 73-82, 2020.
Article in English | MEDLINE | ID: mdl-32207463

ABSTRACT

BACKGROUND: Accurate implant placement in the bone is key to successful implant treatment. Once inserted, it can be difficult to correct the orientation of the implant axis, especially of a one-piece implant. Prosthetic-driven digital implant planning in combination with fully guided implant surgery can offer additional safety in such cases. CASE PRESENTATION: The patient presented with a wide, edentulous interdental space extending from sites 13 to 16, which was to be restored with three one-piece zirconia implants supporting a zirconia fixed partial denture comprizing a cantilever to the mesial aspect. Digital planning based on DICOM (Digital Imaging and Communications in Medicine) and intraoral surface data was performed to ensure optimal positioning. Guided implant placement was executed using a contra-angle handpiece with special attachments and a compatible, sleeveless drill guide. Impressions of the implants for the final restoration were acquired using an intraoral scanner. Reflection-related errors were compensated for by using the given digital abutment geometry. The DICOM and STL datasets were superimposed and used as the basis for fabricating a monolithic zirconia restoration through a subtractive milling process. The final restoration was adhesively cemented. CONCLUSIONS: By using a prosthetic-driven implant planning strategy, it was possible to place the one-piece ceramic implants without an available implant manufacturer's guide-based solution. This was accomplished using a contra-angle surgical handpiece with special attachments and a compatible drill guide. This approach is particularly recommended for the placement of one-piece implants, which otherwise require irreversible abutment grinding for the adjustment of the implant axis orientation after placement. To increase the precision of the digital impressions of the implants, the ideal abutment geometry was imported and superimposed onto the scan data. The results demonstrate that the proposed method can dispense with the need for gingival retraction when acquiring impressions for implants of this type in the future.


Subject(s)
Dental Implants , Workflow , Ceramics , Computer-Aided Design , Denture, Partial, Fixed , Humans
14.
Clin Oral Implants Res ; 30(5): 466-475, 2019 May.
Article in English | MEDLINE | ID: mdl-30972828

ABSTRACT

OBJECTIVES: To assess survival/success rates and patient-reported outcome of zirconia-based posterior single crowns (SCs) supported by zirconia implants in a prospective two-center study after five years of observation. MATERIAL AND METHODS: Forty-five patients were restored with 45 zirconia implant-supported posterior SCs composed of zirconia frameworks hand-layered with a leucite-reinforced feldspathic ceramic. Survival rates of SCs were assessed and technical success was evaluated according to modified United States Public Health Care (USPHS) criteria. Furthermore, patient-reported outcome measures (PROMs) were assessed by applying visual analog scales (VAS). Wilcoxon matched-pairs signed-rank test, mixed-effects ordered logistic regression, and linear mixed models were used to evaluate time effects on response variables. RESULTS: Forty patients were available after a mean observation period of 61.0 ± 1.4 months. One SC had to be replaced, resulting in a Kaplan-Meier (KM) survival estimate for the SCs of 97.5 ± 2.47%. Since nine reconstructions showed at least in one category a major deviation from the ideal (five major chippings, four with increased occlusal roughness, one significant crevice, and one pronounced over-contouring), the KM success estimate was 79.3 ± 5.8%. Incidence of chipping (n = 19) and occlusal roughness (n = 35) was frequent (p < 0.001). All PROMs at prosthetic delivery except for speech (p = 0.139) showed significantly improved VAS scores (81%-94%; p < 0.001) compared to pre-treatment evaluations. Thereafter, no decrease in satisfaction could be observed until the 5-year follow-up (93%-97%). CONCLUSION: Veneered zirconia-based SCs supported by zirconia implants showed high survival rates and highly satisfied patients' needs. However, significant incidence of technical complications is compromising the clinical long-term outcome for this indication.


Subject(s)
Dental Prosthesis Design , Dental Prosthesis, Implant-Supported , Ceramics , Crowns , Dental Restoration Failure , Humans , Prospective Studies , Zirconium
15.
J Clin Periodontol ; 45(1): 114-124, 2018 Jan.
Article in English | MEDLINE | ID: mdl-28902420

ABSTRACT

AIM: This 3-year report of a prospective long-term cohort investigation aimed to evaluate the clinical and radiographic outcomes of a one-piece zirconia oral implant for single-tooth replacement. MATERIALS AND METHODS: Sixty-five patients received a 1-stage implant surgery with immediate temporization. Standardized radiographs were taken at implant insertion, after 1 year, and after 3 years to monitor peri-implant bone levels. A univariate analysis of the association of different baseline parameters on marginal bone loss from implant insertion to 36 months was performed. Soft-tissue parameters were evaluated at prosthesis insertion, after 6 months, after 1 year, and at the 3-year follow-up. RESULTS: After 3 years, six posterior site implants were lost, giving a cumulative survival rate of 90.8%. The mean marginal bone loss was 1.45 mm; 35% of the implants lost at least 2 mm bone, and 22% more than 3 mm. The univariate analysis did not identify any parameter associated with marginal bone loss. Probing depth, clinical attachment level, and bleeding index increased over 3 years, and plaque index decreased. CONCLUSIONS: The low survival rate of the presented ceramic implant and especially the high frequency of advanced bone loss are noticeable but remain unexplained.


Subject(s)
Dental Implants, Single-Tooth , Dental Materials , Dental Prosthesis Design , Zirconium , Adolescent , Adult , Aged , Alveolar Bone Loss/epidemiology , Cohort Studies , Dental Restoration Failure , Female , Humans , Male , Middle Aged , Postoperative Complications/epidemiology , Prospective Studies , Time Factors , Treatment Outcome , Young Adult
16.
Clin Oral Implants Res ; 29(1): 91-99, 2018 Jan.
Article in English | MEDLINE | ID: mdl-28940708

ABSTRACT

OBJECTIVE: To evaluate the clinical and patient-reported outcome of all-ceramic zirconia implant supported fixed dental prostheses (FDPs) 5 years after implant installation. MATERIALS AND METHODS: Thirteen patients were treated with two terminally placed one-piece zirconia implants for a three-unit FDP each. The FDPs consisted of a CAD/CAM-fabricated zirconia framework over-pressed with a fluor-apatite veneering ceramic and were adhesively cemented. Survival and success were assessed by applying modified US Public Health Service (USPHS) criteria and preparation of Kaplan-Meier (KM) plots. Alpha and Bravo ratings were accepted for success (among others including small area veneer chippings and occlusal roughness), whereas Charlie ratings allowing for intra-oral correction (e.g., polishing) were accepted for survival. Furthermore, patient-reported outcome measures (PROMs) were analyzed with the help of visual analogue scales (VAS). Wilcoxon matched-pairs signed-rank test (USPHS criteria) and linear mixed models (PROMs) were used to evaluate time effects on response variables. RESULTS: All patients were available 61.8 ± 1.1 months after implant installation (53.6 ± 3.1 months after final prosthesis insertion). FDP survival was 100%. Significant incidence of veneer chipping (p = .0096) and occlusal roughness (p = .0019) was observed. Charlie rated extent of both phenomena resulted in a KM success estimate of 38.5% (95% CI: 14.1%-62.8%; seven FDPs with obvious roughness, three of them with extended veneer chipping). Compared with the pre-treatment assessments (30%-81% of satisfaction), all surveys at prosthetic delivery showed significantly improved VAS scores (66%-93%; p ≤ .038), except for speech (p = .341). Concerning function, esthetics and self-esteem, no decrease in satisfaction could be observed until the end of follow-up (90%-96%; p ≥ .057), whereas perception of sense (92%) and speech (95%) increased over time (p ≤ .030). Occurrence of technical complications did not correlate with patient satisfaction. CONCLUSIONS: Bi-layered FDPs made from zirconia/fluor-apatite highly satisfied patients but showed significant incidence of technical complications.


Subject(s)
Dental Alloys , Dental Prosthesis Design , Dental Prosthesis, Implant-Supported , Zirconium , Adult , Aged , Apatites , Female , Humans , Male , Materials Testing , Middle Aged , Patient Reported Outcome Measures , Prospective Studies , Survival Analysis
17.
Clin Oral Implants Res ; 29 Suppl 18: 196-223, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30306684

ABSTRACT

OBJECTIVE: This review aimed at evaluating the survival and technical complication rates of all-ceramic implant-supported single crowns (SC). MATERIAL AND METHODS: Three electronic databases were searched for clinical studies conducted at ≥ 15 patients examining implant-supported all-ceramic SCs over ≥ 12 months. Survival rates of implants and restorations plus technical complication rates of SCs were calculated and tested for statistical correlation with confounding variables. Statistical analysis was performed using a negative binomial distribution model to calculate 5- and 10-year survival and complication estimates. RESULTS: Forty-one included studies reported on implant-supported SCs made of veneered and monolithic high-strength oxide ceramics, monolithic, and veneered glass-based ceramics and of a monolithic resin-nano-ceramic (RNC). Survival estimates for SCs of 93% (95% CI: 86.6%-96.4%) after 5 years and 94.4% (95% CI: 91.1%-96.5%) after 10 years were calculated, corresponding values for implant survival were 95.3% (95% CI: 90.6%-97.7%) and 96.2% (95% CI: 95.1%-97.1%). Technical complication rates after 5/10 years were as follows: chipping 9.0% (95% CI: 5.4%-14.8%)/2.7% (95% CI: 2.1%-3.5%), framework fractures 1.9% (95% CI: 0.7%-4.9%)/1.2% (95% CI: 1%-1.5%), screw loosening 3.6% (95% CI: 1.6%-8.4%)/5.2% (95% CI: 3.6%-7.5%), and decementations with 1.1% (95% CI: 0.4%-2.8%) after 5 years. Some confounding variables influenced the above-mentioned estimates significantly. CONCLUSIONS: All-ceramic implant-supported SCs showed-with the exception of a RNC material-high survival rates. However, failures and technical complications occurred which have to be considered when informing patients on the treatment with implant-supported all-ceramic SCs.


Subject(s)
Ceramics/therapeutic use , Crowns , Dental Materials/therapeutic use , Dental Prosthesis, Implant-Supported , Crowns/adverse effects , Dental Prosthesis, Implant-Supported/adverse effects , Dental Prosthesis, Implant-Supported/microbiology , Dental Restoration Failure , Humans
18.
Clin Oral Implants Res ; 29 Suppl 18: 224-236, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30306694

ABSTRACT

OBJECTIVE: To assess the survival and technical complication rate of partial and full-arch all-ceramic implant-supported fixed dental prostheses (P-FDP/FA-FDP) and supporting implants. MATERIALS AND METHODS: An electronic search through three databases (MEDLINE/Pubmed, Cochrane Library, Embase) was conducted to identify relevant clinical studies with an observation period of at least 12 months, including ≥15 patients. Reconstruction and implant survival rates, technical complications and confounding variables such as processed/installed materials, retention mode and location in the mouth were obtained. Failure and complication rates were analyzed using standard Poisson regression models to calculate 5-year survival and complication estimates. RESULTS: A total of five studies for the P-FDP group and seven studies for the FA-FDP group were included, throughout evaluating veneered zirconia reconstructions. In the P-FDP group, reconstructions were located in posterior regions. Meta-analysis indicated survival estimates on the reconstruction level of 98.3% and 97.7% for P- and FA-FDPs after 5 years. However, chipping of the veneering ceramic was frequent, resulting in estimated 5-year complication rates of 22.8% (P-FDPs) and 34.8% (FA-FDPs). Five-year survival estimates of implants supporting P-FDPs and FA-FDPs of 98.5% and 99.4% were calculated, respectively. Including a total of 540 FDPs, one screw-loosening and 11 de-cementations were reported. Confounding variables were not found to have a significant influence on survival and complication rates. CONCLUSIONS: All-ceramic implant-supported P- and FA-FDPs comprising veneered zirconia frameworks showed high survival but clinically inacceptable fracture rates of the veneering ceramic. Their suitability with regard to this indication and a successful long-term outcome needs to be further evaluated.


Subject(s)
Ceramics/therapeutic use , Dental Materials/therapeutic use , Denture, Complete , Denture, Partial, Fixed , Ceramics/adverse effects , Dental Materials/adverse effects , Dental Prosthesis, Implant-Supported , Dental Restoration Failure , Denture, Complete/adverse effects , Denture, Partial, Fixed/adverse effects , Humans
19.
Clin Oral Implants Res ; 29(3): 290-299, 2018 Mar.
Article in English | MEDLINE | ID: mdl-29330869

ABSTRACT

AIM: The aim of the present investigation was to evaluate clinically and radiographically the outcome of zirconia oral implants after 3 years in function. MATERIALS AND METHODS: In 60 patients in need of either a single-tooth replacement or a three-unit fixed dental prosthesis (FDP), a total of 71 one-piece zirconia implants were placed and immediately restored with temporary fixed prostheses. After a period of at least 2 months in the mandible and at least 4 months in the maxilla, zirconia-based reconstructions were cemented. The implants were clinically and radiologically examined at implant insertion, prosthetic delivery, at 6 months and then yearly up to 3 years. A linear mixed model was used to analyze statistically the influence of prognostic factors on changes in the marginal bone level. RESULTS: Seventy-one implants (48 in the mandible, 23 in the maxilla) inserted in 60 patients were restored with 49 crowns and 11 FDP. One patient lost his implant after 5 weeks. Five patients with one implant each could not be evaluated after 3 years. Based on 55 patients with a total of 66 implants, the mean survival rate was 98.5% after 3 years in function. A statistically significant mean marginal bone loss (0.70 mm ± 0.72 mm) has been detected from implant insertion to the 3-year follow-up. The largest marginal bone loss occurred between implantation and prosthetic delivery (0.67 mm ± 0.56 mm). After delivery, no statistically significant bone level change was observed (0.02 mm ± 0.59 mm). None of the investigated prognostic factors had a significant influence on changes in the marginal bone level. CONCLUSIONS: After 3 years in function, the investigated one-piece zirconia implant showed a high survival rate and a low marginal bone loss. The implant system was successful for single-tooth replacement and three-unit FDPs. Further investigations with long-term data are needed to confirm these findings.


Subject(s)
Alveolar Bone Loss/pathology , Dental Implants, Single-Tooth , Dental Implants , Dental Prosthesis, Implant-Supported , Dental Restoration Failure , Denture, Partial, Fixed , Zirconium , Adult , Alveolar Bone Loss/diagnostic imaging , Alveolar Process/diagnostic imaging , Crowns , Dental Abutments , Dental Implant-Abutment Design , Dental Implantation, Endosseous , Dental Plaque Index , Dental Prosthesis Design , Dental Restoration, Temporary , Female , Humans , Immediate Dental Implant Loading , Male , Mandible/diagnostic imaging , Mandible/surgery , Maxilla/diagnostic imaging , Maxilla/surgery , Middle Aged , Periodontal Index , Prospective Studies , Survival Analysis
20.
Clin Oral Implants Res ; 29 Suppl 18: 237-242, 2018 10.
Article in English | MEDLINE | ID: mdl-30306691

ABSTRACT

OBJECTIVES: The tasks of this working group were to evaluate the existing evidence on the efficiency and efficacy of the digital and conventional workflows for the fabrication of fixed implant reconstructions, to assess the performance of all-ceramic fixed implant reconstructions and, finally, to evaluate the outcomes of internally and externally connected implant abutments and reconstructions. METHODS: Four reviews were available analyzing the current literature on the respective topics. One review dealt with the efficiency and efficacy of digital and conventional fabrication workflows. Two reviews analyzed the outcomes of all-ceramic fixed implant reconstructions, one focusing on single-implant reconstructions and the other evaluating multiple-unit implant fixed dental prostheses (FDPs). The fourth review evaluated the clinical outcome on external, respectively, internal implant-abutment connections. These reviews were the basis for the discussions within the group and at the plenary sessions. RESULTS: The present consensus report gives the consensus statements, the clinical recommendations, and the implications for future research as discussed and approved by the plenum of the consensus conference. The four manuscripts by Mühlemann et al., Rabel et al., Pieralli et al., and Pjetursson et al. are published as part of the journal supplement of the present EAO consensus conference.


Subject(s)
Computer-Aided Design , Dental Prosthesis Design , Ceramics/therapeutic use , Crowns , Dental Abutments , Dental Implant-Abutment Design/methods , Dental Materials/therapeutic use , Dental Prosthesis Design/methods , Dental Prosthesis, Implant-Supported/methods , Denture Design/methods , Humans
SELECTION OF CITATIONS
SEARCH DETAIL