Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 52
Filter
2.
Bioconjug Chem ; 32(8): 1802-1811, 2021 08 18.
Article in English | MEDLINE | ID: mdl-34161070

ABSTRACT

With the advent of novel immunotherapies, interest in ex vivo autologous cell labeling for in vivo cell tracking has revived. However, current clinically available labeling strategies have several drawbacks, such as release of radiolabel over time and cytotoxicity. Poly(lactic-co-glycolic acid) nanoparticles (PLGA NPs) are clinically used biodegradable carriers of contrast agents, with high loading capacity for multimodal imaging agents. Here we show the development of PLGA-based NPs for ex vivo cell labeling and in vivo cell tracking with SPECT. We used primary amine-modified PLGA polymers (PLGA-NH2) to construct NPs similar to unmodified PLGA NPs. PLGA-NH2 NPs were efficiently radiolabeled without chelator and retained the radionuclide for 2 weeks. Monocyte-derived dendritic cells labeled with [111In]In-PLGA-NH2 showed higher specific activity than those labeled with [111In]In-oxine, with no negative effect on cell viability. SPECT/CT imaging showed that radiolabeled THP-1 cells accumulated at the Staphylococcus aureus infection site in mice. In conclusion, PLGA-NH2 NPs are able to retain 111In, independent of chelator presence. Furthermore, [111In]In-PLGA-NH2 allows cell labeling with high specific activity and no loss of activity over prolonged time intervals. Finally, in vivo tracking of ex vivo labeled THP-1 cells was demonstrated in an infection model using SPECT/CT imaging.


Subject(s)
Cell Tracking , Nanoparticles/chemistry , Polylactic Acid-Polyglycolic Acid Copolymer/chemistry , Radiopharmaceuticals/chemical synthesis , Amines/chemistry , Animals , Cell Survival , Female , Humans , Mice , Radiopharmaceuticals/pharmacology , THP-1 Cells
3.
Cytotherapy ; 23(9): 757-773, 2021 09.
Article in English | MEDLINE | ID: mdl-33832818

ABSTRACT

Cell-based therapies have been making great advances toward clinical reality. Despite the increase in trial activity, few therapies have successfully navigated late-phase clinical trials and received market authorization. One possible explanation for this is that additional tools and technologies to enable their development have only recently become available. To support the safety evaluation of cell therapies, the Health and Environmental Sciences Institute Cell Therapy-Tracking, Circulation and Safety Committee, a multisector collaborative committee, polled the attendees of the 2017 International Society for Cell & Gene Therapy conference in London, UK, to understand the gaps and needs that cell therapy developers have encountered regarding safety evaluations in vivo. The goal of the survey was to collect information to inform stakeholders of areas of interest that can help ensure the safe use of cellular therapeutics in the clinic. This review is a response to the cellular imaging interests of those respondents. The authors offer a brief overview of available technologies and then highlight the areas of interest from the survey by describing how imaging technologies can meet those needs. The areas of interest include imaging of cells over time, sensitivity of imaging modalities, ability to quantify cells, imaging cellular survival and differentiation and safety concerns around adding imaging agents to cellular therapy protocols. The Health and Environmental Sciences Institute Cell Therapy-Tracking, Circulation and Safety Committee believes that the ability to understand therapeutic cell fate is vital for determining and understanding cell therapy efficacy and safety and offers this review to aid in those needs. An aim of this article is to share the available imaging technologies with the cell therapy community to demonstrate how these technologies can accomplish unmet needs throughout the translational process and strengthen the understanding of cellular therapeutics.

4.
Adv Funct Mater ; 29(19)2019 May 09.
Article in English | MEDLINE | ID: mdl-32132881

ABSTRACT

Ultrasound is the most commonly used clinical imaging modality. However, in applications requiring cell-labeling, the large size and short active lifetime of ultrasound contrast agents limit their longitudinal use. Here, 100 nm radius, clinically applicable, polymeric nanoparticles containing a liquid perfluorocarbon, which enhance ultrasound contrast during repeated ultrasound imaging over the course of at least 48 h, are described. The perfluorocarbon enables monitoring the nanoparticles with quantitative 19F magnetic resonance imaging, making these particles effective multimodal imaging agents. Unlike typical core-shell perfluorocarbon-based ultrasound contrast agents, these nanoparticles have an atypical fractal internal structure. The nonvaporizing highly hydrophobic perfluorocarbon forms multiple cores within the polymeric matrix and is, surprisingly, hydrated with water, as determined from small-angle neutron scattering and nuclear magnetic resonance spectroscopy. Finally, the nanoparticles are used to image therapeutic dendritic cells with ultrasound in vivo, as well as with 19F MRI and fluorescence imaging, demonstrating their potential for long-term in vivo multimodal imaging.

5.
Nanomedicine ; 18: 391-401, 2019 06.
Article in English | MEDLINE | ID: mdl-30448526

ABSTRACT

Herein, we maximize the labeling efficiency of cardiac progenitor cells (CPCs) using perfluorocarbon nanoparticles (PFCE-NP) and 19F MRI detectability, determine the temporal dynamics of single-cell label uptake, quantify the temporal viability/fluorescence persistence of labeled CPCs in vitro, and implement in vivo, murine cardiac CPC MRI/tracking that could be translatable to humans. FuGENEHD-mediated CPC PFCE-NP uptake is confirmed with flow cytometry/confocal microscopy. Epifluorescence imaging assessed temporal viability/fluorescence (up to 7 days [D]). Nonlocalized murine 19F MRS and cardiac MRI studied label localization in terminal/longitudinal tracking studies at 9.4 T (D1-D8). A 4-8 fold 19F concentration increase is evidenced in CPCs for FuGENE vs. directly labeled cells. Cardiac 19F signals post-CPC injections diminished in vivo to ~31% of their values on D1 by D7/D8. Histology confirmed CPC retention, dispersion, and macrophage-induced infiltration. Intra-cardiac injections of PFCE-NP-labeled CPCs with FuGENE can be visualized/tracked in vivo for the first time with 19F MRI.


Subject(s)
Cell Tracking , Endocytosis , Fluorine/chemistry , Fluorocarbons/metabolism , Magnetic Resonance Imaging , Myocardium/cytology , Nanoparticles/chemistry , Stem Cells/metabolism , Animals , Cell Survival , Female , Fluorescence , Mice, Inbred C57BL , Signal-To-Noise Ratio , Time Factors
6.
Biol Proced Online ; 19: 6, 2017.
Article in English | MEDLINE | ID: mdl-28674481

ABSTRACT

BACKGROUND: In vitro labelling of cells and small cell structures is a necessary step before in vivo monitoring of grafts. We modified and optimised a procedure for pancreatic islet labelling using bimodal positively charged poly(lactic-co-glycolic acid) nanoparticles with encapsulated perfluoro crown ethers and indocyanine green dye via microporation and compared the method with passive endocytosis. RESULTS: Pancreatic islets were microporated using two pulses at various voltages. We tested a standard procedure (poration in the presence of nanoparticles) and a modified protocol (pre-microporation in a buffer only, and subsequent islet incubation with nanoparticles on ice for 10 min). We compared islet labelling by microporation with labelling by endocytosis, i.e. pancreatic islets were incubated for 24 h in a medium with suspended nanoparticles. In order to verify the efficiency of the labelling procedures, we used 19F magnetic resonance imaging, optical fluorescence imaging and confocal microscopy. The experiment confirmed that microporation, albeit fast and effective, is invasive and may cause substantial harm to islets. To achieve sufficient poration and to minimise the reduction of viability, the electric field should be set at 20 kV/m (two pulses, 20 ms each). Poration in the presence of nanoparticles was found to be unsuitable for the nanoparticles used. The water suspension of nanoparticles (which served as a surfactant) was slightly foamy and microbubbles in the suspension were responsible for sparks causing the destruction of islets during poration. However, pre-microporation (poration of islets in a buffer only) followed by 10-min incubation with nanoparticles was safer. CONCLUSIONS: For labelling of pancreatic islets using poly(lactic-co-glycolic acid) nanoparticles, the modified microporation procedure with low voltage was found to be safer than the standard microporation procedure. The modified procedure was fast, however, efficiency was lower compared to endocytosis.

7.
J Magn Reson Imaging ; 45(6): 1659-1667, 2017 06.
Article in English | MEDLINE | ID: mdl-27990708

ABSTRACT

PURPOSE: To assess the uptake, accumulation, temporal stability, and spatial localization of isoflurane (ISO) in the C57BL/6 mouse, and to identify its potential interference with the detection of labeled cardiac progenitor cells using 19 F MRI/MR spectroscopy (MRS). MATERIALS AND METHODS: Objectives are demonstrated using (a) in vitro ISO tests, (b) in vivo temporal accumulation/spatial localization C57BL/6 studies (n = 3), and (c) through injections of perfluoro-crown-ether (PFCE) labeled cardiac progenitor cells into femoral muscle areas of the murine hindlimb post-mortem (n = 1) using 1 H/19 F MRI/MRS at 9.4 Tesla. Data were acquired using double-gated spoiled gradient echo images and pulse-acquire spectra. For the in vivo study, the temporal stability of ISO resonances was quantified using coefficient of variability (CV) (5 min) estimates. RESULTS: Two ISO resonances were observed in vivo that correspond to the -CF3 and -OCHF2 moieties. CV values ranged between 3.2 and 6.4% (-CF3 ) and 6.4 and 11.2% (-OCHF2 ). Reductions of the ISO dose (2.0 to 1.7%) at 80 min postinduction had insignificant effects on ISO signals (P = 0.23; P = 0.71). PFCE-labeled cells exhibited a resonance at -16.25 ppm in vitro that did not overlap with the ISO resonances, a finding that is confirmed with MRS post-mortem using injected, labeled cells. Based on 19 F MRI, similar in vivo/post-mortem ISO compartmentalization was also confirmed in peripheral and thoracic skeletal muscles. CONCLUSION: Significant ISO accumulation was observed by 19 F MRS in vivo with temporally stable signals over 90 min postinduction. ISO effects on PFCE labels are anticipated to be minimal but may be more prominent for perfluoropolyether or perfluorooctyl bromide labels. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;45:1659-1667.


Subject(s)
Artifacts , Cell Tracking/methods , Ethers/pharmacokinetics , Fluorocarbons/pharmacokinetics , Isoflurane/pharmacokinetics , Magnetic Resonance Imaging , Stem Cells/cytology , Stem Cells/metabolism , Animals , Cells, Cultured , Contrast Media , Fluorine Radioisotopes/pharmacokinetics , Isoflurane/pharmacology , Male , Metabolic Clearance Rate , Mice , Mice, Inbred C57BL , Reproducibility of Results , Sensitivity and Specificity , Stem Cells/drug effects , Tissue Distribution
8.
Eur Radiol ; 25(3): 726-35, 2015 Mar.
Article in English | MEDLINE | ID: mdl-25373770

ABSTRACT

(19)F MRI is emerging as a new imaging technique for cell tracking. It is particularly attractive because of its potential for direct and precise cell quantification. The most important challenge towards in vivo applications is the sensitivity of the technique, i.e. the detection limit in a reasonable imaging time. Optimal sensitivity can be achieved with dedicated (19)F compounds together with specifically adapted hardware and acquisition methods. In this paper we introduce the (19)F MRI technique focusing on these key sensitivity issues and review the state-of-the-art of (19)F MRI and developments towards its clinical use. We calculate (19)F detection limits reported in preclinical cell and clinical (19)F drug studies in terms of tissue concentration in a 1 cm(3) voxel, as an alternate way to compare detection limits. We estimate that a tissue concentration of a few millimoles per litre (mM) of (19)F is required for a human study at a resolution of 1 cm(3).


Subject(s)
Cell Tracking/methods , Fluorine-19 Magnetic Resonance Imaging/methods , Contrast Media , Diagnostic Imaging , Fluorine-19 Magnetic Resonance Imaging/instrumentation , Humans , Magnetic Fields
9.
Mol Pharm ; 11(12): 4299-313, 2014 Dec 01.
Article in English | MEDLINE | ID: mdl-25290882

ABSTRACT

Dendritic cells (DCs) are the most potent antigen-presenting cells (APCs), involved in the induction of immunity and currently exploited for antitumor immunotherapies. An optimized noninvasive imaging modality capable of determining and quantifying DC-targeted nanoparticle (NP) trajectories could provide valuable information regarding therapeutic vaccine outcome. Here, targeted poly(d,l-lactide-co-glycolide) nanoparticles (PLGA NPs) recognizing DC receptors were equipped with superparamagnetic iron oxide particles (SPIO) or gold nanoparticles with fluorescently labeled antigen. The fluorescent label allowed for rapid analysis and quantification of DC-specific uptake of targeted PLGA NPs in comparison to uptake by other cells. Transmission electron microscopy (TEM) showed that a fraction of the encapsulated antigen reached the lysosomal compartment of DCs, where SPIO and gold were already partially released. However, part of the PLGA NPs localized within the cytoplasm, as confirmed by confocal microscopy. DCs targeted with NPs carrying SPIO or fluorescent antigen were detected within lymph nodes as early as 1 h after injection by magnetic resonance imaging (MRI). Despite the fact that targeting did not markedly affect PLGA NP biodistribution on organism and tissue level, it increased delivery of NPs to DCs residing in peripheral lymph nodes and resulted in enhanced T cell proliferation. In conclusion, two imaging agents within a single carrier allows tracking of targeted PLGA NPs at the subcellular, cellular, and organismal levels, thereby facilitating the rational design of in vivo targeted vaccination strategies.


Subject(s)
Drug Carriers/chemistry , Nanoparticles/chemistry , Nanostructures/chemistry , Animals , Cells, Cultured , Contrast Media , Dendritic Cells/immunology , Humans , Mice , Microscopy, Electron, Transmission , Vaccines/immunology
10.
Cell Mol Life Sci ; 70(13): 2237-57, 2013 Jul.
Article in English | MEDLINE | ID: mdl-23052208

ABSTRACT

Immunotherapy aims to re-engage and revitalize the immune system in the fight against cancer. Research over the past decades has shown that the relationship between the immune system and human cancer is complex, highly dynamic, and variable between individuals. Considering the complexity, enormous effort and costs involved in optimizing immunotherapeutic approaches, clinically applicable tools to monitor therapy-induced immune responses in vivo are most warranted. However, the development of such tools is complicated by the fact that a developing immune response encompasses several body compartments, e.g., peripheral tissues, lymph nodes, lymphatic and vascular systems, as well as the tumor site itself. Moreover, the cells that comprise the immune system are not static but constantly circulate through the vascular and lymphatic system. Molecular imaging is considered the favorite candidate to fulfill this task. The progress in imaging technologies and modalities has provided a versatile toolbox to address these issues. This review focuses on the detection of therapy-induced anticancer immune responses in vivo and provides a comprehensive overview of clinically available imaging techniques as well as perspectives on future developments. In the discussion, we will focus on issues that specifically relate to imaging of the immune system and we will discuss the strengths and limitations of the current clinical imaging techniques. The last section provides future directions that we envision to be crucial for further development.


Subject(s)
Immunotherapy/methods , Neoplasms/immunology , Cancer Vaccines/therapeutic use , Diagnostic Imaging/methods , Humans , Immunity, Active , Lymph Nodes/immunology , Lymph Nodes/pathology , Lymphocyte Activation , Models, Immunological , Neoplasms/pathology , Neoplasms/therapy
12.
Proc Natl Acad Sci U S A ; 108(45): 18396-9, 2011 Nov 08.
Article in English | MEDLINE | ID: mdl-22025695

ABSTRACT

Current biomarkers are unable to adequately predict vaccine-induced immune protection in humans with infectious disease or cancer. However, timely and adequate assessment of antigen-specific immune responses is critical for successful vaccine development. Therefore, we have developed a method for the direct assessment of immune responses in vivo in a clinical setting. Melanoma patients with lymph node (LN) metastases received dendritic cell (DC) vaccine therapy, injected intranodally, followed by [(18)F]-labeled 3'-fluoro-3'-deoxy-thymidine ([(18)F]FLT) PET at varying time points after vaccination. Control LNs received saline or DCs without antigen. De novo immune responses were readily visualized in treated LNs early after the prime vaccination, and these signals persisted for up to 3 wk. This selective [(18)F]FLT uptake was markedly absent in control LNs, although tracer uptake in treated LNs increased profoundly with as little as 4.5 × 10(5) DCs. Immunohistochemical staining confirmed injected DC dispersion to T-cell areas and resultant activation of CD4(+) and CD8(+) T cells. The level of LN tracer uptake significantly correlates to the level of circulating antigen-specific IgG antibodies and antigen-specific proliferation of T cells in peripheral blood. Furthermore, this correlation was not observed with [(18)F]-labeled fluoro-2-deoxy-2-D-glucose. Therefore, [(18)F]FLT PET offers a sensitive tool to study the kinetics, localization, and involvement of lymphocyte subsets in response to vaccination. This technique allows for early discrimination of responding from nonresponding patients in anti-cancer vaccination and aid physicians in individualized decisionmaking.


Subject(s)
Antigens, Neoplasm/immunology , Cancer Vaccines/administration & dosage , Dideoxynucleosides , Fluorodeoxyglucose F18 , Melanoma/diagnostic imaging , Positron-Emission Tomography/methods , Radiopharmaceuticals , CD4-Positive T-Lymphocytes/immunology , CD8-Positive T-Lymphocytes/immunology , Cancer Vaccines/immunology , Humans , Lymphatic Metastasis/diagnostic imaging , Lymphatic Metastasis/immunology , Melanoma/immunology , Melanoma/pathology
13.
Nanoscale ; 15(44): 18068-18079, 2023 Nov 16.
Article in English | MEDLINE | ID: mdl-37916411

ABSTRACT

19F magnetic resonance imaging (19F MRI) is an emerging technique for quantitative imaging in novel therapies, such as cellular therapies and theranostic nanocarriers. Nanocarriers loaded with liquid perfluorocarbon (PFC) typically have a (single) core-shell structure with PFC in the core due to the poor miscibility of PFC with organic and inorganic solvents. Paramagnetic relaxation enhancement acts only at a distance of a few angstroms. Thus, efficient modulation of the 19F signal is possible only with fluorophilic PFC-soluble chelates. However, these chelates cannot interact with the surrounding environment and they might result in image artifacts. Conversely, chelates bound to the nanoparticle shell typically have a minimal effect on the 19F signal and a strong impact on the aqueous environment. We show that the confinement of PFC in biodegradable polymeric nanoparticles (NPs) with a multicore structure enables the modulation of longitudinal (T1) and transverse (T2) 19F relaxation, as well as proton (1H) signals, using non-fluorophilic paramagnetic chelates. We compared multicore NPs versus a conventional single core structure, where the PFC is encapsulated in the core(s) and the chelate in the surrounding polymeric matrix. This modulated relaxation also makes multicore NPs sensitive to various acidic pH environments, while preserving their stability. This effect was not observed with single core nanocapsules (NCs). Importantly, paramagnetic chelates affected both T1 and T219F relaxation in multicore NPs, but not in single core NCs. Both relaxation times of the 19F nucleus were enhanced with an increasing concentration of the paramagnetic chelate. Moreover, as the polymeric matrix remained water permeable, proton enhancement additionally was observed in MRI.


Subject(s)
Fluorocarbons , Nanoparticles , Gadolinium/chemistry , Contrast Media/pharmacology , Contrast Media/chemistry , Protons , Magnetic Resonance Imaging/methods , Fluorocarbon Polymers , Chelating Agents/pharmacology , Fluorocarbons/chemistry , Nanoparticles/chemistry
14.
BJR Open ; 5(1): 20230019, 2023.
Article in English | MEDLINE | ID: mdl-37953866

ABSTRACT

Magnetic resonance imaging (MRI) plays a significant role in the routine imaging workflow, providing both anatomical and functional information. 19F MRI is an evolving imaging modality where instead of 1H, 19F nuclei are excited. As the signal from endogenous 19F in the body is negligible, exogenous 19F signals obtained by 19F radiofrequency coils are exceptionally specific. Highly fluorinated agents targeting particular biological processes (i.e., the presence of immune cells) have been visualised using 19F MRI, highlighting its potential for non-invasive and longitudinal molecular imaging. This article aims to provide both a broad overview of the various applications of 19F MRI, with cancer imaging as a focus, as well as a practical guide to 19F imaging. We will discuss the essential elements of a 19F system and address common pitfalls during acquisition. Last but not least, we will highlight future perspectives that will enhance the role of this modality. While not an exhaustive exploration of all 19F literature, we endeavour to encapsulate the broad themes of the field and introduce the world of 19F molecular imaging to newcomers. 19F MRI bridges several domains, imaging, physics, chemistry, and biology, necessitating multidisciplinary teams to be able to harness this technology effectively. As further technical developments allow for greater sensitivity, we envision that 19F MRI can help unlock insight into biological processes non-invasively and longitudinally.

15.
Int J Cardiol Heart Vasc ; 44: 101111, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36820389

ABSTRACT

Background: Aim of this study was to investigate immune cells and subsets in different stages of human coronary artery disease with a novel multiplex immunohistochemistry (mIHC) technique. Methods: Human left anterior descending coronary artery specimens were analyzed: eccentric intimal thickening (N = 11), pathological intimal thickening (N = 10), fibroatheroma (N = 9), and fibrous plaque (N = 9). Eccentric intimal thickening was considered normal, and pathological intimal thickening, fibroatheroma, and fibrous plaque were considered diseased coronary arteries. Two mIHC panels, consisting of six and five primary antibodies, autofluoresence, and DAPI, were used to detect adaptive and innate immune cells. Via semi-automated analysis, (sub)types of immune cells in whole plaques and specific plaque regions were quantified. Results: Increased numbers of CD3+ T cells (P < 0.001), CD20+ B cells (P = 0.013), CD68+ macrophages (P = 0.003), CD15+ neutrophils (P = 0.017), and CD31+ endothelial cells (P = 0.024) were identified in intimas of diseased coronary arteries compared to normal. Subset analyses of T cells and macrophages showed that diseased coronary arteries contained an abundance of CD3+CD8- non-cytotoxic T cells and CD68+CD206- non-M2-like macrophages. Proportions of CD3+CD45RO+ memory T cells were similar to normal coronary arteries. Among pathological intimal thickening, fibroatheroma, and fibrous plaque, all immune cell numbers and subsets were similar. Conclusions: The type of immune response does not differ substantially between different stages of plaque development and may provide context for mechanistic research into immune cell function in atherosclerosis. We provide the first comprehensive map of immune cell subtypes across plaque types in coronary arteries demonstrating the potential of mIHC for vascular research.

16.
Front Cardiovasc Med ; 10: 1127685, 2023.
Article in English | MEDLINE | ID: mdl-37057097

ABSTRACT

Background: Bicuspid aortic valve (BAV) is associated with ascending aorta aneurysms and dissections. Presently, genetic factors and pathological flow patterns are considered responsible for aneurysm formation in BAV while the exact role of inflammatory processes remains unknown. Methods: In order to objectify inflammation, we employ a highly sensitive, quantitative immunohistochemistry approach. Whole slides of dissected, dilated and non-dilated ascending aortas from BAV patients were quantitatively analyzed. Results: Dilated aortas show a 4-fold increase of lymphocytes and a 25-fold increase in B lymphocytes in the adventitia compared to non-dilated aortas. Tertiary lymphoid structures with B cell follicles and helper T cell expansion were identified in dilated and dissected aortas. Dilated aortas were associated with an increase in M1-like macrophages in the aorta media, in contrast the number of M2-like macrophages did not change significantly. Conclusion: This study finds unexpected large numbers of immune cells in dilating aortas of BAV patients. These findings raise the question whether immune cells in BAV aortopathy are innocent bystanders or contribute to the deterioration of the aortic wall.

17.
Mol Imaging Biol ; 24(1): 71-81, 2022 02.
Article in English | MEDLINE | ID: mdl-34671928

ABSTRACT

PURPOSE: Isoflurane (ISO) is the most commonly used preclinical inhalation anesthetic. This is a problem in 19F MRI of fluorine contrast agents, as ISO signals cause artifacts that interfere with unambiguous image interpretation and quantification; the two most attractive properties of heteronuclear MRI. We aimed to avoid these artifacts using MRI strategies that can be applied by any pre-clinical researcher. PROCEDURES: Three strategies to avoid ISO chemical shift displacement artifacts (CSDA) in 19F MRI are described and demonstrated with measurements of 19F-containing agents in phantoms and in vivo (n = 3 for all strategies). The success of these strategies is compared to a standard Rapid Acquisition with Relaxation Enhancement (RARE) sequence, with phantom and in vivo validation. ISO artifacts can successfully be avoided by (1) shifting them outside the region of interest using a narrow signal acquisition bandwidth, (2) suppression of ISO by planning a frequency-selective suppression pulse before signal acquisition or by (3) preventing ISO excitation with a 3D sequence with a narrow excitation bandwidth. RESULTS: All three strategies result in complete ISO signal avoidance (p < 0.0001 for all methods). Using a narrow acquisition bandwidth can result in loss of signal to noise ratio and distortion of the image, and a frequency-selective suppression pulse can be incomplete when B1-inhomogeneities are present. Preventing ISO excitation with a narrow excitation pulse in a 3D sequence yields the most robust results (relative SNR 151 ± 28% compared to 2D multislice methods, p = 0.006). CONCLUSION: We optimized three easily implementable methods to avoid ISO signal artifacts and validated their performance in phantoms and in vivo. We make recommendation on the parameters that pre-clinical studies should report in their method section to make the used approach insightful.


Subject(s)
Artifacts , Isoflurane , Contrast Media/chemistry , Magnetic Resonance Imaging/methods , Phantoms, Imaging , Reproducibility of Results
18.
Elife ; 112022 02 09.
Article in English | MEDLINE | ID: mdl-35137689

ABSTRACT

Background: Chronic Q fever is a zoonosis caused by the bacterium Coxiella burnetii which can manifest as infection of an abdominal aortic aneurysm (AAA). Antibiotic therapy often fails, resulting in severe morbidity and high mortality. Whereas previous studies have focused on inflammatory processes in blood, the aim of this study was to investigate local inflammation in aortic tissue. Methods: Multiplex immunohistochemistry was used to investigate local inflammation in Q fever AAAs compared to atherosclerotic AAAs in aorta tissue specimen. Two six-plex panels were used to study both the innate and adaptive immune systems. Results: Q fever AAAs and atherosclerotic AAAs contained similar numbers of CD68+ macrophages and CD3+ T cells. However, in Q fever AAAs, the number of CD68+CD206+ M2 macrophages was increased, while expression of GM-CSF was decreased compared to atherosclerotic AAAs. Furthermore, Q fever AAAs showed an increase in both the number of CD8+ cytotoxic T cells and CD3+CD8-FoxP3+ regulatory T cells. Finally, Q fever AAAs did not contain any well-defined granulomas. Conclusions: These findings demonstrate that despite the presence of pro-inflammatory effector cells, persistent local infection with C. burnetii is associated with an immune-suppressed microenvironment. Funding: This work was supported by SCAN consortium: European Research Area - CardioVascualar Diseases (ERA-CVD) grant [JTC2017-044] and TTW-NWO open technology grant [STW-14716].


Subject(s)
Adaptive Immunity/immunology , Aortic Aneurysm, Abdominal/immunology , Atherosclerosis/immunology , Immunity, Innate/immunology , Q Fever/immunology , Aged , Aortic Aneurysm, Abdominal/metabolism , Aortic Aneurysm, Abdominal/microbiology , Atherosclerosis/metabolism , Atherosclerosis/microbiology , Female , Humans , Immunohistochemistry/methods , Inflammation/immunology , Inflammation/microbiology , Macrophages/metabolism , Male , Middle Aged , Q Fever/metabolism , Q Fever/microbiology , T-Lymphocytes/metabolism
19.
Int J Cancer ; 129(2): 365-73, 2011 Jul 15.
Article in English | MEDLINE | ID: mdl-20839261

ABSTRACT

Monitoring of cell therapeutics in vivo is of major importance to estimate its efficacy. Here, we present a novel intracellular label for (19)F magnetic resonance imaging (MRI)-based cell tracking, which allows for noninvasive, longitudinal cell tracking without the use of radioisotopes. A key advantage of (19)F MRI is that it allows for absolute quantification of cell numbers directly from the MRI data. The (19)F label was tested in primary human monocyte-derived dendritic cells. These cells took up label effectively, resulting in a labeling of 1.7 ± 0.1 × 10(13) (19)F atoms per cell, with a viability of 80 ± 6%, without the need for electroporation or transfection agents. This results in a minimum detection sensitivity of about 2,000 cells/voxel at 7 T, comparable with gadolinium-labeled cells. Comparison of the detection sensitivity of cells labeled with (19)F, iron oxide and gadolinium over typical tissue background showed that unambiguous detection of the (19)F-labeled cells was simpler than with the contrast agents. The effect of the (19)F agent on cell function was minimal in the context of cell-based vaccines. From these data, we calculate that detection of 30,000 cells in vivo at 3 T with a reasonable signal to noise ratio for (19)F images would require less than 30 min with a conventional fast spin echo sequence, given a coil similar to the one used in this study. This is well within acceptable limits for clinical studies, and thus, we conclude that (19)F MRI for quantitative cell tracking in a clinical setting has great potential.


Subject(s)
Cell Movement , Contrast Media , Dendritic Cells/physiology , Fluorine , Fluorocarbons , Magnetic Resonance Imaging/methods , Cancer Vaccines , Cell Count , Dendritic Cells/immunology , Feasibility Studies , Humans
20.
Open Res Eur ; 1: 138, 2021.
Article in English | MEDLINE | ID: mdl-37645150

ABSTRACT

We would like to share data from a survey run by the Young Academy of Europe (YAE) from June to October 2020, with questions aiming to unravel the situation of early-career researchers (including early stage group leaders) working in Europe, during the COVID-19 pandemic. We were particularly interested in the impact of care activities (related to young children or other family members), and the impact of gender. We include the online survey and collected data, without identifying information. The survey is published in Nature Career Column (July, 2021) ( https://www.nature.com/articles/d41586-021-01952-6).

SELECTION OF CITATIONS
SEARCH DETAIL