Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 116
Filter
1.
Biomed Microdevices ; 20(4): 93, 2018 10 29.
Article in English | MEDLINE | ID: mdl-30374706

ABSTRACT

The use of radioactive nanoparticles as imaging and therapeutic agents is increasing globally. Indeed, the use of these nanoparticles as perfect theranostic agent is highly anticipated in the pharmaceutical market. Among the radioactive nanoparticles, liposomes, solid lipid nanoparticles and polymeric nanoparticles are the most studied. However little information among adverse reactions, absorbed dose and correct dose to achieve the theranostic goal in a translational application is available. We developed a radioactive polymeric nanoparticle and calculated the absorbed dose in animal model (Wistar rats) using the OLINDA/EXM program. The results showed that some nanoparticle were uptake in five organs and minor elimination through the gastrointestinal and urinary pathways. The data corroborates the safe use in terms of blood-brain barrier and did not show high uptake by liver. The dosimetry data support the safe use of radioactive nanoparticles as theranostic agent. Graphical abstract Ć”Ā…ĀŸ.


Subject(s)
Nanoparticles/therapeutic use , Radiation Dosage , Theranostic Nanomedicine , Animals , Isotope Labeling , Rats , Rats, Wistar , Tissue Distribution
2.
Pediatr Radiol ; 47(6): 691-700, 2017 May.
Article in English | MEDLINE | ID: mdl-28283725

ABSTRACT

BACKGROUND: The estimation of organ doses and effective doses for children receiving CT examinations is of high interest. Newer, more realistic anthropomorphic body models can provide information on individual organ doses and improved estimates of effective dose. MATERIALS AND METHODS: Previously developed body models representing 50th-percentile individuals at reference ages (newborn, 1, 5, 10 and 15Ā years) were modified to represent 10th, 25th, 75th and 90th height percentiles for both genders and an expanded range of ages (3, 8 and 13Ā years). We calculated doses for 80 pediatric reference phantoms from simulated chest-abdomen-pelvis exams on a model of a Philips Brilliance 64 CT scanner. Individual organ and effective doses were normalized to dose-length product (DLP) and fit as a function of body diameter. RESULTS: We calculated organ and effective doses for 80 reference phantoms and plotted them against body diameter. The data were well fit with an exponential function. We found DLP-normalized organ dose to correlate strongly with body diameter (R2>0.95 for most organs). Similarly, we found a very strong correlation with body diameter for DLP-normalized effective dose (R2>0.99). Our results were compared to other studies and we found average agreement of approximately 10%. CONCLUSION: We provide organ and effective doses for a total of 80 reference phantoms representing normal-stature children ranging in age and body size. This information will be valuable in replacing the types of vendor-reported doses available. These data will also permit the recording and tracking of individual patient doses. Moreover, this comprehensive dose database will facilitate patient matching and the ability to predict patient-individualized dose prior to examination.


Subject(s)
Phantoms, Imaging , Radiometry/methods , Tomography, X-Ray Computed , Adolescent , Body Size , Child , Child, Preschool , Humans , Infant , Radiation Dosage
3.
Pediatr Radiol ; 45(12): 1771-80, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26142256

ABSTRACT

BACKGROUND: Organ dose is essential for accurate estimates of patient dose from CT. OBJECTIVE: To determine organ doses from a broad range of pediatric patients undergoing diagnostic chest-abdomen-pelvis CT and investigate how these relate to patient size. MATERIALS AND METHODS: We used a previously validated Monte Carlo simulation model of a Philips Brilliance 64 multi-detector CT scanner (Philips Healthcare, Best, The Netherlands) to calculate organ doses for 40 pediatric patients (M:F = 21:19; range 0.6-17 years). Organ volumes and positions were determined from the images using standard segmentation techniques. Non-linear regression was performed to determine the relationship between volume CT dose index (CTDIvol)-normalized organ doses and abdominopelvic diameter. We then compared results with values obtained from independent studies. RESULTS: We found that CTDIvol-normalized organ dose correlated strongly with exponentially decreasing abdominopelvic diameter (R(2) > 0.8 for most organs). A similar relationship was determined for effective dose when normalized by dose-length product (R(2) = 0.95). Our results agreed with previous studies within 12% using similar scan parameters (e.g., bowtie filter size, beam collimation); however results varied up to 25% when compared to studies using different bowtie filters. CONCLUSION: Our study determined that organ doses can be estimated from measurements of patient size, namely body diameter, and CTDIvol prior to CT examination. This information provides an improved method for patient dose estimation.


Subject(s)
Multidetector Computed Tomography/statistics & numerical data , Pelvis/diagnostic imaging , Radiation Dosage , Radiography, Abdominal/statistics & numerical data , Radiography, Thoracic/statistics & numerical data , Adolescent , Child , Child, Preschool , Female , Humans , Infant , Male , Monte Carlo Method
4.
Health Phys ; 2024 Sep 19.
Article in English | MEDLINE | ID: mdl-39297777

ABSTRACT

ABSTRACT: Objectives: To analyze the effects of normal x-ray inspection, machine washing, and machine drying on thermoluminescent dosimeter (TLD) measurements during external individual monitoring and to provide suggestions for determining individual monitoring measurements under the mentioned abnormal situations. In this study, we focused on three abnormal situations: x-ray inspection, machine washing, and machine drying, which are common in external individual dose monitoring. We measured and compared the doses from TLD with and without 11, 23, 35, and 50 security checks. We used different radiation sources to expose the TLDs before or after machine washing with or without hot drying. The three radiation sources are natural background radiation, 137Cs ƎĀ³ rays, and 320 kVp x-rays. We measured 20 TLDs for each situation. The average doses for the TLDs with 11, 23, 35, 50 security checks are 27.7 ĀµGy, 59.7 ĀµGy, 84.1 ĀµGy, and 121.0 ĀµGy, respectively. We measured an average dose of 2.5 ĀµGy per exposure. The doses showed no significant difference between different times of washing with different radiation sources, natural background radiation, 137Cs, or x-ray exposures. There was also no significant difference between the dose coming from the controlled group, drying at 60 Ā°C and 90 Ā°C for 1 h after exposure to 137Cs ƎĀ³ rays and 320 kVp x-rays. The common machine drying under the temperature of 90 Ā°C did not affect TLD measured doses.

5.
Health Phys ; 124(5): 397-406, 2023 05 01.
Article in English | MEDLINE | ID: mdl-36780284

ABSTRACT

ABSTRACT: The OLINDA/EXM version 2.0 personal computer code was created as an upgrade to the widely used OLINDA/EXM 1.0 and 1.1 codes. This paper documents the upgrades that were implemented. New decay data and anthropomorphic and biokinetic models were implemented in the software, and the software alpha and beta tested. Agreement of doses between the OLINDA/EXM codes 1 and 2 was very good. Use of the new anthropomorphic and biokinetic models results in understandable differences between the codes. Previous models were retained in the new code, and those results were identical to those in the previous code. OLINDA/EXM 2.0 represents an upgrade from version 1, with new modeling data recommended by the international community. It standardizes internal dose calculations for dose assessments in clinical trials with radiopharmaceuticals, theoretical calculations for existing pharmaceuticals, teaching, and other purposes.


Subject(s)
Nuclear Medicine , Software , Radionuclide Imaging , Radiopharmaceuticals , Radiometry/methods
6.
Blood ; 116(13): 2241-4, 2010 Sep 30.
Article in English | MEDLINE | ID: mdl-20522711

ABSTRACT

Care of patients with AL amyloidosis currently is limited by the lack of objective means to document disease extent, as well as therapeutic options that expedite removal of pathologic deposits. To address these issues, we have initiated a Phase I Exploratory IND study to determine the biodistribution of the fibril-reactive, amyloidolytic murine IgG1 mAb 11-1F4 labeled with I-124. Patients were infused with less than 1 mg (Ć¢ĀˆĀ¼ 74 MBq) of GMP-grade antibody and imaged by PET/CT scan 48 and 120 hours later. Among 9 of 18 subjects, there was striking uptake of the reagent in liver, lymph nodes, bone marrow, intestine, or, unexpectedly, spleen (but not kidneys or heart). Generally, positive or negative results correlated with those obtained immunohistochemically using diagnostic tissue biopsy specimens. Based on these findings, we posit that (124)I-mAb m11-1F4 can be used to identify AL candidates for passive immunotherapy using the chimeric form of the antibody.


Subject(s)
Amyloid/metabolism , Amyloidosis/diagnostic imaging , Amyloidosis/metabolism , Aged , Animals , Antibodies, Monoclonal , Drugs, Investigational , Female , Humans , Immunoglobulin G , Iodine Radioisotopes , Male , Mice , Middle Aged , Positron-Emission Tomography , Radioimmunodetection , Tissue Distribution
7.
J Nucl Med ; 63(3): 485-492, 2022 03.
Article in English | MEDLINE | ID: mdl-34353873

ABSTRACT

This paper presents standardized methods for performing dose calculations for radiopharmaceuticals. Various steps in the process are outlined, with some specific examples given. Special models for calculating time-activity integrals (urinary bladder, intestines) are also reviewed. This article can be used as a template for designing and executing kinetic studies for calculating radiation dose estimates from animal or human data.


Subject(s)
Data Analysis , Radiopharmaceuticals , Animals , Kinetics , Radiation Dosage , Radiometry/methods
8.
J Nucl Med ; 63(2): 316-322, 2022 Feb.
Article in English | MEDLINE | ID: mdl-34353875

ABSTRACT

This paper presents standardized methods for collecting data to be used in performing dose calculations for radiopharmaceuticals. Various steps in the process are outlined, with some specific examples given. This document can be used as a template for designing and executing kinetic studies for calculating radiation dose estimates, from animal or human data.


Subject(s)
Radiometry , Radiopharmaceuticals , Animals , Kinetics , Radiation Dosage , Radiometry/methods
9.
EJNMMI Res ; 12(1): 21, 2022 Apr 11.
Article in English | MEDLINE | ID: mdl-35403982

ABSTRACT

BACKGROUND: Extrapolation of human absorbed doses (ADs) from biodistribution experiments on laboratory animals is used to predict the efficacy and toxicity profiles of new radiopharmaceuticals. Comparative studies between available animal-to-human dosimetry extrapolation methods are missing. We compared five computational methods for mice-to-human AD extrapolations, using two different radiopharmaceuticals, namely [111In]CHX-DTPA-scFv78-Fc and [68Ga]NODAGA-RGDyK. Human organ-specific time-integrated activity coefficients (TIACs) were derived from biodistribution studies previously conducted in our centre. The five computational methods adopted are based on simple direct application of mice TIACs to human organs (M1), relative mass scaling (M2), metabolic time scaling (M3), combined mass and time scaling (M4), and organ-specific allometric scaling (M5), respectively. For [68Ga]NODAGA-RGDyK, these methods for mice-to-human extrapolations were tested against the ADs obtained on patients, previously published by our group. Lastly, an average [68Ga]NODAGA-RGDyK-specific allometric parameter αnew was calculated from the organ-specific biological half-lives in mouse and humans and retrospectively applied to M3 and M4 to assess differences in human AD predictions with the α = 0.25 recommended by previous studies. RESULTS: For both radiopharmaceuticals, the five extrapolation methods showed significantly different AD results (p < 0.0001). In general, organ ADs obtained with M3 were higher than those obtained with the other methods. For [68Ga]NODAGA-RGDyK, no significant differences were found between ADs calculated with M3 and those obtained directly on human subjects (H) (p = 0.99; average M3/H AD ratio = 1.03). All other methods for dose extrapolations resulted in ADs significantly different from those calculated directly on humans (all p ≤ 0.0001). Organ-specific allometric parameters calculated using combined experimental [68Ga]NODAGA-RGDyK mice and human biodistribution data varied significantly. ADs calculated with M3 and M4 after the application of αnew = 0.17 were significantly different from those obtained by the application of α = 0.25 (both p < 0.001). CONCLUSIONS: Available methods for mouse-to-human dosimetry extrapolations provided significantly different results in two different experimental models. For [68Ga]NODAGA-RGDyK, the best approximation of human dosimetry was shown by M3, applying a metabolic scaling to the mouse organ TIACs. The accuracy of more refined extrapolation algorithms adopting model-specific metabolic scaling parameters should be further investigated.

10.
Med Phys ; 38(8): 4824-45, 2011 Aug.
Article in English | MEDLINE | ID: mdl-21928655

ABSTRACT

Yttrium-90 microsphere brachytherapy of the liver exploits the distinctive features of the liver anatomy to treat liver malignancies with beta radiation and is gaining more wide spread clinical use. This report provides a general overview of microsphere liver brachytherapy and assists the treatment team in creating local treatment practices to provide safe and efficient patient treatment. Suggestions for future improvements are incorporated with the basic rationale for the therapy and currently used procedures. Imaging modalities utilized and their respective quality assurance are discussed. General as well as vendor specific delivery procedures are reviewed. The current dosimetry models are reviewed and suggestions for dosimetry advancement are made. Beta activity standards are reviewed and vendor implementation strategies are discussed. Radioactive material licensing and radiation safety are discussed given the unique requirements of microsphere brachytherapy. A general, team-based quality assurance program is reviewed to provide guidance for the creation of the local procedures. Finally, recommendations are given on how to deliver the current state of the art treatments and directions for future improvements in the therapy.


Subject(s)
Brachytherapy/standards , Liver Neoplasms/radiotherapy , Yttrium Radioisotopes/therapeutic use , Angiography/standards , Health Physics , Humans , Image Interpretation, Computer-Assisted/standards , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/pathology , Magnetic Resonance Imaging , Microspheres , Positron-Emission Tomography , Quality Assurance, Health Care/standards , Radiometry/standards , Societies, Medical , Tomography, X-Ray Computed , United States , Yttrium Radioisotopes/standards
11.
Mayo Clin Proc ; 95(3): 449-458, 2020 03.
Article in English | MEDLINE | ID: mdl-32138878

ABSTRACT

OBJECTIVE: To determine if heparin labeled with 99mTechnetium (99mTc) could be an imaging probe to detect eosinophil-related inflammation in eosinophilic esophagitis and to determine the biodistribution and radiation dosimetry of 99mTc-heparin oral administration using image-based dosimetry models with esophageal modeling. METHODS: Freshly prepared 99mTc-heparin was administered orally to 5 research subjects. Radioactivity was measured by whole-body scintigraphy and single-photon emission computed tomography during the 24 hours postadministration. Following imaging, endoscopic examination was performed. The biodistribution of esophageal radioactivity was compared with endoscopic findings, eosinophil counts in biopsy tissues, and immunostaining for eosinophil granule major basic protein-1 (eMBP1). These studies were conducted from July 1, 2013, until April 22,Ā 2017. RESULTS: Oral administration of 99mTc-heparin was well tolerated in all 5 subjects. The entire esophagus could be visualized dynamically during oral administration. Bound esophageal radioactivity marked areas of inflammation as judged by endoscopy scores, by eosinophils per high power field and by localization of eMBP1 using immunostaining. Ninety percent of the radioactivity did not bind to the esophagus and passed through the gastrointestinal tract. CONCLUSION: The biodistribution of ingested 99mTc-heparin is almost exclusively localized to the gastrointestinal tract. Radiation exposure was highest in the lower gastrointestinal tract and was comparable with other orally administered diagnostic radiopharmaceuticals. The use of swallowed 99mTc-heparin may aid in assessing eosinophil-related inflammation in the esophagus.


Subject(s)
Eosinophilic Esophagitis/diagnostic imaging , Heparin/administration & dosage , Organotechnetium Compounds/administration & dosage , Radiopharmaceuticals/administration & dosage , Tomography, Emission-Computed, Single-Photon , Administration, Oral , Adult , Esophagoscopy , Humans , Male , Middle Aged , Tissue Distribution , Whole Body Imaging
12.
Radiology ; 253(2): 520-31, 2009 Nov.
Article in English | MEDLINE | ID: mdl-19789227

ABSTRACT

The U.S. National Council on Radiation Protection and Measurements and United Nations Scientific Committee on Effects of Atomic Radiation each conducted respective assessments of all radiation sources in the United States and worldwide. The goal of this article is to summarize and combine the results of these two publicly available surveys and to compare the results with historical information. In the United States in 2006, about 377 million diagnostic and interventional radiologic examinations and 18 million nuclear medicine examinations were performed. The United States accounts for about 12% of radiologic procedures and about one-half of nuclear medicine procedures performed worldwide. In the United States, the frequency of diagnostic radiologic examinations has increased almost 10-fold (1950-2006). The U.S. per-capita annual effective dose from medical procedures has increased about sixfold (0.5 mSv [1980] to 3.0 mSv [2006]). Worldwide estimates for 2000-2007 indicate that 3.6 billion medical procedures with ionizing radiation (3.1 billion diagnostic radiologic, 0.5 billion dental, and 37 million nuclear medicine examinations) are performed annually. Worldwide, the average annual per-capita effective dose from medicine (about 0.6 mSv of the total 3.0 mSv received from all sources) has approximately doubled in the past 10-15 years.


Subject(s)
Diagnostic Imaging/statistics & numerical data , Nuclear Medicine/statistics & numerical data , Radiation Dosage , Radiology/statistics & numerical data , Diagnostic Imaging/trends , Humans , Internationality , United States
13.
J Nucl Med ; 2024 Aug 14.
Article in English | MEDLINE | ID: mdl-39142830
14.
J Nucl Med ; 60(7): 937-943, 2019 07.
Article in English | MEDLINE | ID: mdl-31263080

ABSTRACT

With the recent approval of 177Lu-DOTATATE for use in gastroenteropancreatic neuroendocrine tumors, access to peptide receptor radionuclide therapy is increasing. Representatives from the North American Neuroendocrine Tumor Society and the Society of Nuclear Medicine and Molecular Imaging collaborated to develop a practical consensus guideline for the administration of 177Lu-DOTATATE. In this paper, we discuss patient screening, maintenance somatostatin analog therapy requirements, treatment location and room preparation, drug administration, and patient release as well as strategies for radiation safety, toxicity monitoring, management of potential complications, and follow-up. Controversies regarding the role of radiation dosimetry are discussed as well. This document is designed to provide practical guidance on how to safely treat patients with this therapy.


Subject(s)
Neuroendocrine Tumors/radiotherapy , Nuclear Medicine , Octreotide/analogs & derivatives , Organometallic Compounds/therapeutic use , Receptors, Somatostatin/metabolism , Societies, Medical/standards , Bone Marrow/radiation effects , Humans , Kidney/radiation effects , Octreotide/administration & dosage , Octreotide/adverse effects , Octreotide/therapeutic use , Organometallic Compounds/administration & dosage , Organometallic Compounds/adverse effects , Organs at Risk/radiation effects , Radiometry , Reference Standards , Safety
15.
J Nucl Med ; 49(9): 1555-63, 2008 Sep.
Article in English | MEDLINE | ID: mdl-18765586

ABSTRACT

UNLABELLED: The technical basis for the dose estimates for several radiopharmaceuticals used in nuclear cardiology is reviewed, and cases in which uncertainty has been encountered in the dosimetry of an agent are discussed. Also discussed is the issue of uncertainties in radiation dose estimates and how to compare the relative risks of studies. METHODS: Radiation dose estimates (organ absorbed doses and effective doses) from different literature sources were directly compared. Typical values for administered activity per study were used to compare doses that are to be expected in clinical applications. RESULTS: The effective doses for all agents varied from 2 to 15 mSv per study, with the lowest values being seen for (13)N-NH(3) and (15)O-H(2)O studies and the highest values being seen for (201)Tl-chloride studies. The effective doses for (99m)Tc- and (201)Tl-labeled agents differed by about a factor of 2, a factor that is comparable to the uncertainty in individual values. This uncertainty results from the application of standard anthropomorphic and biokinetic models, presumably representative of the exposed population, to individual patients. CONCLUSION: Considerations such as diagnostic accuracy, ease of use, image quality, and patient comfort and convenience should generally dictate the choice of a radiopharmaceutical, with radiation dose being only a secondary or even tertiary consideration. Counseling of nuclear medicine patients who may be concerned about exposure should include a reasonable estimate of the median dose for the type of examination and administered activity of the radiopharmaceutical; in addition, it should be explained that the theoretic risks of the procedure are orders of magnitude lower than the actual benefits of the examination. Providing numeric estimates of risks from studies to individual patients is inappropriate, given the uncertainties in the dose estimates and the limited predictive power of current dose-risk models in the low-dose (i.e., diagnostic) range.


Subject(s)
Body Burden , Cardiology/statistics & numerical data , Diagnostic Imaging/statistics & numerical data , Nuclear Medicine/statistics & numerical data , Radiometry/methods , Radiopharmaceuticals/analysis , Risk Assessment/methods , Whole-Body Counting/statistics & numerical data , Humans , Relative Biological Effectiveness , Risk Factors
16.
J Nucl Med ; 49(5): 853-60, 2008 May.
Article in English | MEDLINE | ID: mdl-18413398

ABSTRACT

This paper presents a systematic analysis of the inherent uncertainty in internal dose calculations for radiopharmaceuticals. A generic equation for internal dose is presented, and the uncertainty in each of the individual terms is analyzed, with the relative uncertainty of all terms compared. The combined uncertainties in most radiopharmaceutical dose estimates will be typically at least a factor of 2 and may be considerably greater. In therapy applications, if patient-individualized absorbed doses are calculated, with attention being paid to accurate data gathering and analysis and measurement of individual organ volumes, many of the model-based uncertainties can be removed, and the total uncertainty in an individual dose estimate can be reduced to a value of perhaps +/-10%-20%. Radiation dose estimates for different diagnostic radiopharmaceuticals should be appreciated and considered, but small differences in dose estimates between radiopharmaceuticals should not be given too much importance when one is choosing radiopharmaceuticals for general clinical use. Diagnostic accuracy, ease of use, image quality, patient comfort, and other similar factors should predominate in the evaluation, with radiation dose being another issue considered while balancing risks and benefits appropriately.


Subject(s)
Radiation Dosage , Radiometry/methods , Radiopharmaceuticals/therapeutic use , Uncertainty , Female , Humans , Male , Models, Biological , Radiotherapy Dosage , Sensitivity and Specificity
17.
J Nucl Med ; 49(8): 1299-304, 2008 Aug.
Article in English | MEDLINE | ID: mdl-18632816

ABSTRACT

UNLABELLED: Our purpose was to evaluate the safety profile and biodistribution behavior in healthy human volunteers of the new myocardial perfusion tracer bis[(dimethoxypropylphosphanyl)ethyl]ethoxyethylamine N,N'-bis(ethoxyethyl)dithiocarbamato nitrido technetium(V) (99mTc-N-DBODC). METHODS: Ten healthy male volunteers were injected with 99mTc-N-DBODC under both stress and rest conditions. Anterior and posterior planar gamma-camera images were collected at 5, 30, 60, 240, and 1,440 min after injection, with organ uptake quantified by region-of-interest analysis. Tracer kinetics in body fluids were determined by collecting blood and urine samples at different time points. RESULTS: After injection, 99mTc-N-DBODC showed significant accumulation in the myocardium and prolonged retention. Under rest conditions, uptake in the heart, lungs, and liver at 5 min after injection was 1.67% +/- 0.13%, 1.16% +/- 0.07%, and 10.85% +/- 1.72%, respectively, of administered activity. Under stress conditions, heart uptake was significantly higher (2.07% +/- 0.22%). Radioactivity in the liver decreased to 3.64% +/- 0.98% and 2.37% +/- 0.48% at 60 and 240 min, respectively, after injection. This rapid liver clearance led to favorable heart-to-liver ratios, reaching values of 0.74 +/- 0.13 at rest and 1.26 +/- 0.28 during exercise 60 min after tracer administration. Radiation dose estimates were comparable to those obtained with other myocardial perfusion cationic compounds. CONCLUSION: The high uptake in the myocardium and the fast liver washout of 99mTc-N-DBODC will allow SPECT images of the left ventricle to be acquired early and with excellent quality.


Subject(s)
Heart/diagnostic imaging , Organophosphorus Compounds/pharmacokinetics , Organotechnetium Compounds/pharmacokinetics , Radiation Dosage , Radiopharmaceuticals/pharmacokinetics , Adult , Humans , Male , Middle Aged , Organ Specificity , Radionuclide Imaging , Whole Body Imaging
18.
Semin Nucl Med ; 38(5): 308-20, 2008 Sep.
Article in English | MEDLINE | ID: mdl-18662553

ABSTRACT

Basic calculational methods and models used in dose assessment for internal emitters in nuclear medicine are discussed in this overview. Methods for quantification of activity in clinical and preclinical studies also are discussed, and we show how to implement them in currently available dose calculational models. Current practice of the use of internal emitters in therapy also is briefly presented here. Some of the future challenges for dose assessment in nuclear medicine are discussed, including application of patient-specific dose calculational methods and the need for significant advances in radiation biology.


Subject(s)
Algorithms , Body Burden , Models, Biological , Nuclear Medicine/methods , Radioisotopes/analysis , Radiometry/methods , Computer Simulation , Humans , Relative Biological Effectiveness
19.
Semin Nucl Med ; 38(5): 335-46, 2008 Sep.
Article in English | MEDLINE | ID: mdl-18662555

ABSTRACT

In this review, we trace the origins of mathematical modeling methods and pay particular attention to radiotracer applications. Nuclear medicine has been advanced greatly by the efforts of the Society of Nuclear Medicine's Medical Internal Radiation Dose Committee. Well-developed mathematical methods and tools have been created in support of a wide range of applications. Applications of mathematical modeling extend well beyond biology and medicine and are essential to analysis is a wide range of fields that rely on numerical predictions, eg, weather, economic, and various gaming applications. We start with the discovery of radioactivity and radioactive transformations and illustrate selected applications in biology, physiology, and pharmacology. We discuss compartment models as tools used to frame the context of specific problems. A definition of terms, methods, and examples of particular problems follows. We present models of different applications with varying complexity depending on the features of the particular system and function being analyzed. Commonly used analysis tools and methods are described, followed by established models which describe dosimetry along gastrointestinal and urinary excretory pathways, ending finally with a brief discussion of bone marrow dose. We conclude pointing to more recent, promising methods, not yet widely used in dosimetry applications, which aim at coupling pharmacokinetic data with other patient data to correlate patient outcome (benefits and risk) with the type, amount, kind and timing of the therapy the patient received.


Subject(s)
Algorithms , Body Burden , Models, Biological , Nuclear Medicine/methods , Radioisotopes/analysis , Radiometry/methods , Computer Simulation , Humans , Kinetics , Radioisotopes/therapeutic use , Relative Biological Effectiveness
20.
Med Phys ; 35(7): 3215-24, 2008 Jul.
Article in English | MEDLINE | ID: mdl-18697546

ABSTRACT

Estimates of radiation absorbed doses from radionuclides internally deposited in a pregnant woman and her fetus are very important due to elevated fetal radiosensitivity. This paper reports a set of specific absorbed fractions (SAFs) for use with the dosimetry schema developed by the Society of Nuclear Medicine's Medical Internal Radiation Dose (MIRD) Committee. The calculations were based on three newly constructed pregnant female anatomic models, called RPI-P3, RPI-P6, and RPI-P9, that represent adult females at 3-, 6-, and 9-month gestational periods, respectively. Advanced Boundary REPresentation (BREP) surface-geometry modeling methods were used to create anatomically realistic geometries and organ volumes that were carefully adjusted to agree with the latest ICRP reference values. A Monte Carlo user code, EGS4-VLSI, was used to simulate internal photon emitters ranging from 10 keV to 4 MeV. SAF values were calculated and compared with previous data derived from stylized models of simplified geometries and with a model of a 7.5-month pregnant female developed previously from partial-body CT images. The results show considerable differences between these models for low energy photons, but generally good agreement at higher energies. These differences are caused mainly by different organ shapes and positions. Other factors, such as the organ mass, the source-to-target-organ centroid distance, and the Monte Carlo code used in each study, played lesser roles in the observed differences in these. Since the SAF values reported in this study are based on models that are anatomically more realistic than previous models, these data are recommended for future applications as standard reference values in internal dosimetry involving pregnant females.


Subject(s)
Fetus/radiation effects , Neoplasms/radiotherapy , Pregnancy Complications, Neoplastic , Radiometry/methods , Radiotherapy Planning, Computer-Assisted/methods , Female , Gestational Age , Humans , Maternal Exposure , Monte Carlo Method , Neoplasms/complications , Particle Accelerators , Phantoms, Imaging , Photons , Pregnancy , Scattering, Radiation
SELECTION OF CITATIONS
SEARCH DETAIL