Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 92
Filter
1.
Europace ; 26(8)2024 Aug 03.
Article in English | MEDLINE | ID: mdl-39082698

ABSTRACT

Cardioneuroablation has emerged as a potential alternative to cardiac pacing in selected cases with vasovagal reflex syncope, extrinsic vagally induced sinus bradycardia-arrest or atrioventricular block. The technique was first introduced decades ago, and its use has risen over the past decade. However, as with any intervention, proper patient selection and technique are a prerequisite for a safe and effective use of cardioneuroablation therapy. This document aims to review and interpret available scientific evidence and provide a summary position on the topic.


Subject(s)
Bradycardia , Syncope, Vasovagal , Humans , Bradycardia/therapy , Bradycardia/physiopathology , Bradycardia/surgery , Bradycardia/diagnosis , Syncope, Vasovagal/surgery , Syncope, Vasovagal/diagnosis , Syncope, Vasovagal/physiopathology , Treatment Outcome , Catheter Ablation/methods , Consensus , Heart Rate , Ablation Techniques
2.
Indian Pacing Electrophysiol J ; 21(6): 403-406, 2021.
Article in English | MEDLINE | ID: mdl-34186197

ABSTRACT

We present a case study article demonstrating successful implementation of ultrasound guided extra cardiac vagus nerve stimulation during cardioneuroablation. To our knowledge it is first published description of this technique, as most ECVS are done in the internal jugular vein bulb area. This method allows for reduction of fluoroscopy time, and most importantly reproducible vagus nerve capture especially after full bi-nodal (sinus and atrioventricular) cardioneuroablation when stimulation of vagus nerve may not give any effect in the heart. This article includes a case study with "dual component" atrioventricular block, where functional component is cured with cardioneuroablation, but structural (PR elongation) remains after procedure.

4.
Echocardiography ; 35(9): 1326-1334, 2018 09.
Article in English | MEDLINE | ID: mdl-29900593

ABSTRACT

AIM: Left atrial (LA) fibrosis promotes atrial fibrillation (AF), may predict poor radiofrequency catheter ablation (RFCA) outcome, and may be assessed invasively using electroanatomical mapping (EAM). Speckle tracking echocardiography (STE) enables quantitative assessment of LA function. The aim was to assess the relationship between LA fibrosis derived from EAM and LA echocardiographic parameters as well as biomarkers of fibrosis in patients with AF. METHODS: Sixty-six patients (64% males, mean age 56 ± 10) with nonvalvular AF treated with first RFCA were prospectively studied. Seventy-three percent of patients were in sinus rhythm at the time of examination. LA geometry, systolic, and diastolic function were assessed. In STE global, peak atrial longitudinal (PALS) and contractile (PACS) strain were calculated. LA stiffness index (LAs) - the ratio of E/e' to PALS - was assessed. The EAM of LA was build using Carto System before RFCA. Low amplitude potentials area (LAPA) was quantitatively analyzed and expressed as a percentage of LA surface using the cut-off <0.5 mV to detect potential sites of fibrosis. The serum concentrations of MMP-9, PIIINP, and TGFß1were estimated before RFCA. RESULTS: Pearson correlation analysis showed a significant correlation between LA diastolic function parameters: PALS (-0.54, P < .001), LAs (0.65, P < .001), and LAPA in patients who were in sinus rhythm. Also LA volume significantly correlated with LAPA (0.44, P < .002). None of biomarkers correlated with LAPA. CONCLUSION: Left atrial diastolic parameters derived from STE correlate well with the extent of LA fibrosis. Thus, STE may be useful in the noninvasive assessment of LA fibrosis and selection of candidates for RFCA.


Subject(s)
Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/pathology , Echocardiography/methods , Atrial Fibrillation/blood , Biomarkers/blood , Female , Fibrosis , Heart Atria/diagnostic imaging , Heart Atria/pathology , Humans , Male , Matrix Metalloproteinase 9/blood , Middle Aged , Peptide Fragments/blood , Procollagen/blood , Prospective Studies , Transforming Growth Factor beta1/blood
5.
Europace ; 18(4): 578-84, 2016 Apr.
Article in English | MEDLINE | ID: mdl-25995387

ABSTRACT

AIMS: Electrocardiographic diagnosis of wide QRS complex tachycardia (WCT) continues to be challenging as none one of the available methods is specific for ventricular tachycardia (VT) diagnosis. We aimed to construct a method for WCT differentiation based on a scoring system, in which ECGs are graded according to the number of VT-specific features. This novel method was validated and compared with Brugada algorithm and other methods. METHODS AND RESULTS: A total of 786 WCTs (512 VTs) from 587 consecutive patients with a proven diagnosis were analysed by two blinded observers. The VT score method was based on seven ECG features: initial R wave in V1, initial r > 40 ms in V1/V2, notched S in V1, initial R in aVR, lead II R wave peak time ≥50 ms, no RS in V1-V6, and atrioventricular dissociation. Atrioventricular dissociation was assigned two points, and each of the other features was assigned one point. The overall accuracy of VT score ≥1 for VT diagnosis (83%) was higher than that of the aVR (72%, P = 0.001) and Brugada (81%) algorithms. Ventricular tachycardia score ≥3 was present in 66% of VTs and was more specific (99.6%) than any other algorithm/criterion for VT diagnosis. Ventricular tachycardia score ≥4 was present in 33% of VTs and was 100% specific for VT. CONCLUSION: The new ECG-based method provides a certain diagnosis of VT in the majority of patients with VT, identifies unequivocal ECGs, and has superior overall diagnostic accuracy to other ECG methods.


Subject(s)
Algorithms , Electrocardiography/methods , Heart Rate , Heart Ventricles/physiopathology , Signal Processing, Computer-Assisted , Tachycardia, Ventricular/diagnosis , Action Potentials , Adult , Aged , Female , Humans , Japan , Male , Middle Aged , Observer Variation , Poland , Predictive Value of Tests , Reproducibility of Results , Tachycardia, Ventricular/physiopathology
6.
Ann Noninvasive Electrocardiol ; 21(6): 572-579, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27018992

ABSTRACT

BACKGROUND: Acquired long QT syndrome (a-LQTS) is associated with life-threatening ventricular arrhythmias, mainly torsades de pointes (TdP). ECG parameters predicting evolving into ventricular fibrillation (VF) are ill defined. AIMS: To determine ECG parameters preceding and during TdP associated with higher risk of developing VF. METHODS: We analyzed 151 episodes of TdP, recorded in 28 patients with a-LQTS (mean QTc 638 ms ± 57). RESULTS: All 28 patients had prolonged QT interval, (mean QTc 638 ms ± 57) ranging from 502 ms to 858 ms correcting by Bazett's formula. The mean TdP heart rate was 218 bpm ± 38 (mean cycle length of TdP 274 ± 47 ms). We classified TdPs episodes into "slower"-TdP (s-TdP) < 220 bpm (range from 145-220 bpm) observed in 81 (53.6%) episodes and "faster"-TdP (f-TdP) ≥ 220 bpm (ranged from 221-281 bpm) observed in 70 (46.4%) episodes. Among 151 episodes of TdP, 21 (13.9%) were unstable (converted into VF). Out of 81 episodes of "slower"-TdP only 2 (2.5%) episodes converted into VF. The mean coupling interval (CI) of the PVC initiating TdP was 510 ms ± 118, the pause-RR interval was 1147 ms ± 335, the prematurity index (PI) of PVC that initiated TdP was 0.45 ± 0.13. The mean cycle length variability of TdP (VRV-TdP) was 30.79 ms ± 19.7. U wave was observed in 86 episodes (56.9%), among that in 69 episodes, the U/T wave ratio was > 1. Macro T wave alternans was observed in 4 patients. The QT interval was not different in patients with VF(+) and VF(-) episodes, 633 ± 60 and 639 ± 57, respectively. CONCLUSIONS: Some electrocardiographic parameters can be helpful in determining the risk of TdP evolving into VF. The slower ventricular rate (< 220 bpm), the higher rate instability (VRV > 30 ms) and the short episodes < 20 beats could predict benign evolution.


Subject(s)
Electrocardiography , Long QT Syndrome/physiopathology , Torsades de Pointes/physiopathology , Aged , Disease Progression , Female , Humans , Male , Middle Aged , Risk Assessment
7.
J Cardiovasc Electrophysiol ; 25(8): 866-874, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24654678

ABSTRACT

INTRODUCTION: Although the "near-zero-X-Ray" or "No-X-Ray" catheter ablation (CA) approach has been reported for treatment of various arrhythmias, few prospective studies have strictly used "No-X-Ray," simplified 2-catheter approaches for CA in patients with supraventricular tachycardia (SVT). We assessed the feasibility of a minimally invasive, nonfluoroscopic (MINI) CA approach in such patients. METHODS: Data were obtained from a prospective multicenter CA registry of patients with regular SVTs. After femoral access, 2 catheters were used to create simple, 3D electroanatomic maps and to perform electrophysiologic studies. Medical staff did not use lead aprons after the first 10 MINI CA cases. RESULTS: A total of 188 patients (age, 45 ± 21 years; 17% <19 years; 55% women) referred for the No-X-Ray approach were included. They were compared to 714 consecutive patients referred for a simplified approach using X-rays (age, 52 ± 18 years; 7% <19 years; 55% women). There were 9 protocol exceptions that necessitated the use of X-rays. Ultimately, 179/188 patients underwent the procedure without fluoroscopy, with an acute success rate of 98%. The procedure times (63 ± 26 vs. 63 ± 29 minutes, P > 0.05), major complications (0% vs. 0%, P > 0.05) and acute (98% vs. 98%, P > 0.05) and long-term (93% vs. 94%, P > 0.05) success rates were similar in the "No-X-Ray" and control groups. CONCLUSIONS: Implementation of a strict "No-X-Ray, simplified 2-catheter" CA approach is safe and effective in majority of the patients with SVT. This modified approach for SVTs should be prospectively validated in a multicenter study.


Subject(s)
Catheter Ablation/methods , Tachycardia, Supraventricular/surgery , Adolescent , Adult , Aged , Aged, 80 and over , Cardiac Catheters , Catheter Ablation/adverse effects , Catheter Ablation/instrumentation , Child , Child, Preschool , Electrophysiologic Techniques, Cardiac , Equipment Design , Feasibility Studies , Female , Fluoroscopy , Humans , Lead , Male , Middle Aged , Operative Time , Poland , Predictive Value of Tests , Prospective Studies , Protective Clothing , Radiation Dosage , Radiation Protection/instrumentation , Registries , Tachycardia, Supraventricular/diagnostic imaging , Tachycardia, Supraventricular/physiopathology , Time Factors , Treatment Outcome , Young Adult
8.
Cardiology ; 129(2): 93-102, 2014.
Article in English | MEDLINE | ID: mdl-25226811

ABSTRACT

OBJECTIVES: The purpose of this study was to prospectively evaluate the feasibility and diagnostic value of right ventricular overdrive pacing (RVOP) during supraventricular tachycardia (SVT) using a 2-catheter approach with automatic pacing from the right ventricular inflow (RVIT) and outflow tract (RVOT). METHODS: One hundred and thirty-six consecutive patients (with 138 arrhythmias, mean age 36 ± 20 years, range 4-95) were enrolled in this study. Only coronary sinus and ablation catheters were used. RVOP was delivered from RVIT and then from RVOT. Each attempt consisted of 10 synchronized beats delivered at a cycle length of 10-40 ms longer than the tachycardia cycle length. RESULTS: RVOP was sufficient to confirm the transition zone within the first 9 beats in the majority of SVTs. Atrial perturbation (acceleration, delayed) in the transition zone was detected in all patients with orthodromic atrioventricular (AV) reentry. Patients with typical AV nodal reentry, atypical AV nodal reentry and atrial tachycardia did not show atrial timing perturbation during fusion complexes of RVOP. CONCLUSIONS: Synchronized RVOP from RVIT or RVOT is an easy and accurate method for the quick and reliable differential diagnosis of SVT in various clinical settings, particularly when only a limited number of catheters are used.


Subject(s)
Cardiac Pacing, Artificial/methods , Tachycardia, Supraventricular/diagnosis , Adult , Electrocardiography , Feasibility Studies , Female , Heart Atria/physiopathology , Humans , Male , Prospective Studies , Sensitivity and Specificity , Tachycardia, Atrioventricular Nodal Reentry/diagnosis , Tachycardia, Atrioventricular Nodal Reentry/physiopathology , Tachycardia, Supraventricular/physiopathology , Ventricular Function, Right/physiology
9.
Heart Vessels ; 29(6): 808-16, 2014 Nov.
Article in English | MEDLINE | ID: mdl-24121971

ABSTRACT

Integrated backscatter intravascular ultrasound (IB-IVUS) is a useful method for analyzing coronary plaque tissue. We evaluated whether tissue composition determined using IB-IVUS is associated with the progression of stenosis in coronary angiography. Sixty-three nontarget coronary lesions in 63 patients with stable angina were evaluated using conventional IVUS and IB-IVUS. IB-IVUS images were analyzed at 1-mm intervals for a length of 10 mm. After calculating the relative areas of the tissue components using the IB-IVUS system, fibrous volume (FV) and lipid volume (LV) were calculated through integration of the slices, after which percentages of per-plaque volume (%FV/PV, %LV/PV) and per-vessel volume (%FV/VV, %LV/VV) were calculated. Progression of coronary stenosis was interpreted from the increase in percent diameter stenosis (%DS) from baseline to the follow-up period (6­9 months) using quantitative coronary angiography. %DS was 24.1 ± 12.8 % at baseline and 23.2 ± 13.7 % at follow-up. Using IB-IVUS, LV was 31.7 ± 10.5 mm3, and %LV/PV and %LV/VV were 45.6 ± 10.3 % and 20.2 ± 6.0 %, respectively. FV, %FV/PV, and %FV/VV were 35.5 ± 12.1 mm3, 52.1 ± 9.5 %, and 23.4 ± 7.1 %, respectively. The change in %DS was −0.88 ± 7.25 % and correlated closely with %LV/VV (r = 0.27, P = 0.03) on simple regression. Multivariate regression after adjustment for potentially confounding risk factors showed %LV/VV to be correlated independently with changes in %DS (r = 0.42, P = 0.02). Logistic regression analysis after adjusting for confounding coronary risk factors showed LV (odds ratio 1.08; 95 % confidence interval 1.01­1.16; P = 0.03) and %LV/VV (odds ratio 1.13; 95 % confidence interval 1.01­1.28; P = 0.03) to be independent predictors of the progression of angiographic coronary stenosis. Our findings suggest that angiographic luminal narrowing of the coronary artery is likely associated with tissue characteristics. IB-IVUS may provide information about the natural progression of luminal narrowing in coronary stenosis.


Subject(s)
Cardiomyopathy, Dilated , Catheter Ablation/methods , Ventricular Premature Complexes , Aged , Cardiomyopathy, Dilated/complications , Cardiomyopathy, Dilated/diagnosis , Cardiomyopathy, Dilated/epidemiology , Cardiomyopathy, Dilated/physiopathology , Electrocardiography, Ambulatory/methods , Exercise Test/methods , Female , Humans , Male , Middle Aged , Myocardial Contraction , Poland/epidemiology , Prevalence , Retrospective Studies , Stroke Volume , Treatment Outcome , Ventricular Premature Complexes/diagnosis , Ventricular Premature Complexes/epidemiology , Ventricular Premature Complexes/etiology , Ventricular Premature Complexes/therapy
10.
BMC Cardiovasc Disord ; 13: 58, 2013 Aug 13.
Article in English | MEDLINE | ID: mdl-23937302

ABSTRACT

BACKGROUND: Radiofrequency ablation (RFCA) became a treatment of choice in patients with recurrent ventricular tachycardia, ventricular fibrillation, and appropriate interventions of implanted cardioverter-defibrillator (ICD), however, electrical storm (ES) ablation in a pregnant woman has not yet been reported. CASE PRESENTATION: We describe a case of a successful rescue ablation of recurrent ES in a 26-year-old Caucasian woman during her first pregnancy (23rd week). The arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C) was diagnosed 3 years earlier and several drugs as well as 2 ablations failed to control recurrences of ventricular tachycardia. RFCA was performed on the day of the third electric storm. The use of electroanatomic mapping allowed very low X-ray exposure, and after applications in the right ventricular outflow tract, arrhythmia disappeared. Three months after ablation, a healthy girl was delivered without any complications. During twelve-month follow-up there was no recurrence of ventricular tachycardia or ICD interventions. CONCLUSIONS: This case documents the first successful RFCA during ES due to recurrent unstable ventricular arrhythmias in a patient with ARVD/C in pregnancy. Current guidelines recommend metoprolol, sotalol and intravenous amiodarone for prevention of recurrent ventricular tachycardia in pregnancy, however, RFCA should be considered as a therapeutic option in selected cases. The use of 3D navigating system and near zero X-ray approach is associated with minimal radiation exposure for mother and fetus as well as low risk of procedural complication.


Subject(s)
Arrhythmogenic Right Ventricular Dysplasia/surgery , Catheter Ablation/methods , Pregnancy Complications, Cardiovascular/surgery , Adult , Arrhythmogenic Right Ventricular Dysplasia/diagnosis , Arrhythmogenic Right Ventricular Dysplasia/physiopathology , Body Surface Potential Mapping/methods , Female , Humans , Pregnancy , Pregnancy Complications, Cardiovascular/diagnosis , Pregnancy Complications, Cardiovascular/physiopathology , Treatment Outcome
11.
Kardiol Pol ; 81(11): 1113-1121, 2023.
Article in English | MEDLINE | ID: mdl-37937353

ABSTRACT

BACKGROUND: Patients with cardiac implantable electronic devices (CIEDs) may no longer be eligible for continued therapy. AIMS: The study aimed to assess the circumstances under which CIED reimplantation may not be necessary after transvenous lead extraction (TLE). METHODS: A retrospective analysis of 3646 TLE procedures was performed with assessment of indications for device reimplantation. RESULTS: Reimplantation was not performed immediately after TLE in 169 (4.6%) and, in long-term follow-up, in 146 (4.0%) of patients. No further need for CIED reimplantation was mostly associated with establishment of stable sinus rhythm (2.4%), conversion of sinus node dysfunction to chronic atrial fibrillation (AF; 1.4%), or improvement in left ventricular ejection fraction (LVEF) (0.9%). Independent prognostic factors were in the pacing groups: LVEF (odds ratio [OR], 1.03; 95% confidence interval [CI], 1.01-1.05; P <0.001), AF (OR, 3.8; 95% CI, 2.4-15.7; P <0.001), patients' age during first CIED implantation (OR, 0.97; 95% C, 0.96-0.98; P <0.001), and New York Heart Association (NYHA) class (OR, 0.616; 95% CI, 0.43-0.86; P <0.01); in the cardioverter-defibrillator group: LVEF (OR, 1.06; 95% CI, 1.04-1.09; P <001). Non-reimplanted patients had more complex procedures and more frequent complications, but survival after TLE was better in this group of patients. CONCLUSIONS: Reassessment of the need for continuation of CIED therapy should be considered in all patients following lead extraction and also before planned device replacement as TLE delay increases implant duration, complexity, and procedural risk. The predictors of non-reimplantation are a younger age during the first CIED implantation, lower NYHA class, presence of AF, and higher LVEF in pacemaker carriers, and, in the defibrillator group, only higher LVEF. A decision not to reimplant does not negatively affect the long-term prognosis.


Subject(s)
Atrial Fibrillation , Defibrillators, Implantable , Pacemaker, Artificial , Humans , Defibrillators, Implantable/adverse effects , Retrospective Studies , Stroke Volume , Treatment Outcome , Ventricular Function, Left , Device Removal , Pacemaker, Artificial/adverse effects , Atrial Fibrillation/etiology
12.
J Interv Card Electrophysiol ; 66(5): 1231-1242, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36495412

ABSTRACT

BACKGROUND: Radiofrequency catheter ablation (RFCA) of the slow pathway in atrioventricular nodal reentry tachycardia (AVNRT) is associated with high efficacy and low risk of total perioperative or late atrioventricular block. This study aimed to evaluate the efficacy, safety, and feasibility of slow-pathway RFCA for AVNRT using a zero-fluoroscopy approach. METHODS: Data were obtained from a prospective multicenter registry of catheter ablation from January 2012 to February 2018. Consecutive unselected patients with the final diagnosis of AVNRT were recruited. Electrophysiological and 3-dimensional (3D) electroanatomical mapping systems were used to create 3D maps and to navigate only 2 catheters from the femoral access. Acute procedural efficacy was evaluated using the isoproterenol and/or atropine test, with 15-min observation after ablation. Each case of recurrence or complication was consulted at an outpatient clinic during long-term follow-up. RESULTS: Of the 1032 procedures, 1007 (97.5%) were completed without fluoroscopy. Conversion to fluoroscopy was required in 25 patients (2.5%), mainly due to an atypical location of the coronary sinus (n = 7) and catheter instability (n = 7). The mean radiation exposure time was 1.95 ± 1.3 min for these cases. The mean fluoroscopy time for the entire study cohort was 0.05 ± 0.4 min. The mean total procedure time was 44.8 ± 18.6 min. There were no significant in-hospital complications. The total success rate was 96.1% (n = 992), and the recurrence rate was 3.9% (n = 40). CONCLUSION: Slow-pathway RFCA can be safely performed without fluoroscopy, with a minimal risk of complications and a high success rate.


Subject(s)
Atrioventricular Block , Catheter Ablation , Tachycardia, Atrioventricular Nodal Reentry , Humans , Tachycardia, Atrioventricular Nodal Reentry/diagnosis , Prospective Studies , Atrioventricular Block/etiology , Isoproterenol , Fluoroscopy/methods , Catheter Ablation/methods , Treatment Outcome
13.
J Cardiovasc Dev Dis ; 10(9)2023 Sep 11.
Article in English | MEDLINE | ID: mdl-37754821

ABSTRACT

BACKGROUND: Safe discontinuation of pacemaker therapy for vagally mediated bradycardia is a dilemma. The aim of the study was to present the outcomes of a proposed diagnostic and therapeutic process aimed at discontinuing or not restoring pacemaker therapy (PPM) in patients with vagally mediated bradycardia. METHODS: The study group consisted of two subgroups of patients with suspected vagally mediated bradycardia who were considered to have PPM discontinued or not to restore their PPM if cardioneuroablation (CNA) would successfully treat their bradycardia. A group of 3 patients had just their pacemaker explanted but reimplantation was suggested, and 17 patients had preexisting pacemakers implanted. An invasive electrophysiology study was performed. If EPS was negative, extracardiac vagal nerve stimulation (ECVS) was performed. Then, patients with positive ECVS received CNA. Patients with an implanted pacemaker had it programmed to pace at the lowest possible rate. After the observational period and control EPS including ECVS, redo-CNA was performed if pauses were induced. The decision to explant the pacemaker was obtained based on shared decision making (SDM). RESULTS: After initial clinical and electrophysiological evaluation, 17 patients were deemed eligible for CNA (which was then performed). During the observational period after the initial CNA, all 17 patients were clinically asymptomatic. The subsequent invasive evaluation with ECVS resulted in pause induction in seven (41%) patients, and these patients underwent redo-CNA. Then, SDM resulted in the discontinuation of pacemaker therapy or a decision to not perform pacemaker reimplantation in all the patients after CAN. The pacemaker was explanted in 12 patients post-CNA, while in 2 patients explantation was postponed. During a median follow-up of 18 (IQR: 8-22) months, recurrent syncope did not occur in the CNA recipients. CONCLUSIONS: Pacemaker therapy in patients with vagally mediated bradycardia could be discontinued safely after CNA.

14.
Int J Cardiovasc Imaging ; 38(3): 497-506, 2022 Mar.
Article in English | MEDLINE | ID: mdl-34709523

ABSTRACT

Complete elimination of fluoroscopy during radiofrequency ablation (RFA) of idiopathic ventricular arrhythmias (IVAs) originating from the aortic sinus cusp (ASC) is challenging. The aim was to assess the feasibility, safety and a learning curve for a zero-fluoroscopy (ZF) approach in centers using near-zero fluoroscopy (NOX) approach in IVA-ASC. Between 2012 and 2018, we retrospectively enrolled 104 IVA-ASC patients referred for ZF RFA or NOX using a 3-dimensional electroanatomic (3D-EAM) system (Ensite, Velocity, Abbott, USA). Acute, short and long-term outcomes and learning curve for the ZF were evaluated. ZF was completed in 62 of 75 cases (83%) and NOX in 32 of 32 cases (100%). In 13 cases ZF was changed to NOX. No significant differences were found in success rates between ZF and NOX, no major complications were noted. The median procedure and fluoroscopy times were 65.0 [45-81] and 0.0 [0-5] min respectively, being shorter for ZF than for NOX. With growing experience, the preference for ZF significantly increased-43% (23/54) in 2012-2016 vs 98% (52/53) in 2017-2018, with a simultaneous reduction in the procedure time. ZF ablation can be completed in almost all patients with IVA-ASC by operators with previous experience in the NOX approach, and after appropriate training, it was a preferred ablation technique. The ZF approach for IVA-ASC guided by 3D-EAM has a similar feasibility, safety, and effectiveness to the NOX approach.


Subject(s)
Catheter Ablation , Sinus of Valsalva , Arrhythmias, Cardiac/diagnostic imaging , Arrhythmias, Cardiac/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Fluoroscopy , Humans , Predictive Value of Tests , Retrospective Studies , Sinus of Valsalva/diagnostic imaging , Sinus of Valsalva/surgery , Treatment Outcome
15.
Article in English | MEDLINE | ID: mdl-36012002

ABSTRACT

Heart rate monitors (HRMs) are used by millions of athletes worldwide to monitor exercise intensity and heart rate (HR) during training. This case report presents a 34-year-old male amateur soccer player with severe bradycardia who accidentally identified numerous pauses of over 4 s (maximum length: 7.3 s) during sleep on his own HRM with a heart rate variability (HRV) function. Simultaneous HRM and Holter ECG recordings were performed in an outpatient clinic, finding consistent 6.3 s sinus arrests (SA) with bradycardia of 33 beats/min. During the patient's hospitalization for a transient ischemic attack, the longest pauses on the Holter ECG were recorded, and he was suggested to undergo pacemaker implantation. He then reduced the volume/intensity of exercise for 4 years. Afterward, he spent 2 years without any regular training due to depression. After these 6 years, another Holter ECG test was performed in our center, not confirming the aforementioned disturbances and showing a tendency to tachycardia. The significant SA was resolved after a period of detraining. The case indicates that considering invasive therapy was unreasonable, and patient-centered care and shared decision-making play a key role in cardiac pacing therapy. In addition, some sports HRM with an HRV function can help diagnose bradyarrhythmia, both in professional and amateur athletes.


Subject(s)
Bradycardia , Sports , Adult , Athletes , Bradycardia/diagnosis , Bradycardia/etiology , Bradycardia/therapy , Electrocardiography , Electrocardiography, Ambulatory , Heart Rate , Humans , Male
16.
Europace ; 13(1): 51-6, 2011 Jan.
Article in English | MEDLINE | ID: mdl-20880953

ABSTRACT

AIMS: Imaging of the left atrium (LA) is mandatory during catheter ablation of atrial fibrillation (AF) and may be achieved by echocardiography. The aim of the present study was to assess the feasibility of using a recently released transoesophageal echocardiography (TEE) microprobe (micro-TEE) in non-sedated adult patients undergoing AF ablation and to directly compare this new technique with intracardiac echocardiography (ICE). METHODS AND RESULTS: The study group consisted of 12 consecutive patients (8 males, mean age 49 ± 14 years) who underwent first radiofrequency AF ablation. All patients underwent standard TEE, computed tomography, intraprocedural micro-TEE, and ICE. The easiness of introducing the microprobe in the supine position in non-sedated patients in the electrophysiology laboratory, its tolerability, and quality of obtained images were assessed using a five-point scale. There were no problems with microprobe introduction and obtaining images for a mean of 54 ± 17 min. The microprobe was significantly better tolerated than the standard TEE probe (4.3 ± 0.5 vs. 3.4 ± 0.6 points, P < 0.01). The micro-TEE was scored as significantly better than ICE in the assessment of the LA and LA appendage (LAA) anatomy and function. Both techniques were very useful in guiding transseptal puncture, although micro-TEE images were ranked higher by an echocardiographer than by an electrophysiologist (tenting 4.8 ± 0.6 vs. 4.0 ± 0.6 points, P < 0.01), whereas ICE images were ranked equally excellent by both observers. CONCLUSION: In non-sedated patients undergoing AF ablation, the micro-TEE can be used for the assessment of the LA, LAA, and pulmonary veins anatomy as well as the guidance of transseptal puncture.


Subject(s)
Atrial Fibrillation/surgery , Cardiac Imaging Techniques/methods , Catheter Ablation/methods , Echocardiography, Transesophageal/methods , Adult , Cardiac Imaging Techniques/instrumentation , Echocardiography, Transesophageal/instrumentation , Electrophysiologic Techniques, Cardiac , Feasibility Studies , Female , Heart Atria/diagnostic imaging , Humans , Male , Middle Aged , Nasal Cavity , Pulmonary Veins/diagnostic imaging
17.
Arch Med Sci ; 17(6): 1716-1721, 2021.
Article in English | MEDLINE | ID: mdl-34900053

ABSTRACT

The cardiac autonomic nervous system plays an important role in the genesis and maintenance of atrial fibrillation. Although, pulmonary vein isolation is the cornerstone in today's approach to atrial fibrillation ablation, a considerable proportion of patients will recur with atrial arrhythmias following this procedure, especially in the non-paroxysmal forms. The pulmonary vein isolation indirectly targets and ablate the ganglionated plexi. This might ultimately enhance the efficacy of the procedure, but an optimal ablation strategy and a reliable method to confirm and quantify the efficacy of vagal denervation following the procedure might be necessary, thus leading to significantly better results.

18.
Pol Arch Intern Med ; 131(11)2021 11 30.
Article in English | MEDLINE | ID: mdl-34581176

ABSTRACT

Introduction: Atrioventricular nodal reentrant tachycardia (AVNRT) is one of the most common regular supraventricular arrhythmias referred for catheter ablation (CA). In Poland, several families with familial AVNRT (FAVNRT) were reported in Podkarpacie Province (PP). Objectives: We aimed to determine the frequency of FAVNRT in PP compared with other south-eastern provinces of Poland. Patients and methods: Clinical data of 1544 patients with AVNRT diagnosed by invasive electrophysiological study between 2010 and 2019 were screened for FAVNRT. From January 2017 to June 2019, patients were asked to provide details on family history and origin to obtain 3-generation pedigrees. Families with at least 2 members with previous CA of AVNRT were divided into those from south-eastern provinces (SEPs; including PP and bordering provinces [BPs]) and the remaining parts of Poland (RPP). Results: There were 932 patients from SEPs and 612 from RPP. FAVNRT was reported in 45 patients (2.91%) from 27 families, with a higher frequency in SEPs than RPP (4.02% vs 1.17%; P = 0.002) and the highest frequency in PP (6.33% vs 2.47% in BPs; P = 0.004). The risk of FAVNRT was higher in PP compared with BPs (odds ratio, 2.67; 95% CI, 1.36­5.23; P = 0.004) and similar in BPs compared with RPP (odds ratio, 2.14; 95% CI, 0.86­5.34; P = 0.1). Conclusions: A relationship exists between the geographic region and frequency of FAVNRT. A greater distance from PP was associated with less frequent FAVNRT. International cooperation and genetic testing are needed to confirm the genetic impact of FAVNRT in this part of Central Europe.


Subject(s)
Catheter Ablation , Tachycardia, Atrioventricular Nodal Reentry , Arrhythmias, Cardiac/surgery , Catheter Ablation/methods , Europe , Humans , Poland/epidemiology , Tachycardia, Atrioventricular Nodal Reentry/diagnosis , Tachycardia, Atrioventricular Nodal Reentry/epidemiology , Tachycardia, Atrioventricular Nodal Reentry/genetics
19.
Europace ; 12(2): 230-9, 2010 Feb.
Article in English | MEDLINE | ID: mdl-19919967

ABSTRACT

AIMS: Syncope is a common problem. Demographic and clinical characteristics of patients admitted to different types of centres may vary, physician's adherence to the guidelines has been examined only in a few studies, and the requirements for implantable loop recorders (ILR) have not been well defined. The aim of this study was to (i) compare demographic and clinical characteristics of patients with syncope diagnosed and treated in tertiary electrophysiology cardiac centres and those attending syncope units or general hospitals, (ii) assess how physicians adhere to the published guidelines, and (iii) calculate the requirement for ILR insertion. METHODS AND RESULTS: In total, 669 consecutive patients with syncope, admitted to 18 electrophysiological cardiac tertiary centres over a mean of 3 months (range 1-10 months), entered a special Internet database called the PL-US (Polish patients with Unexplained Syncope) registry. Detailed demographic and clinical characteristics of the patients, including the results of all diagnostic tests performed, were analysed. Adherence to the guidelines was assessed, based on the published recommendations. The ILR implantation was indicated when (i) all other tests were inconclusive (unexplained syncope) and (ii) syncope associated with injury or presence of organic heart disease or past medical history and ECG suggesting arrhythmic syncope. Syncope of cardiac/arrhythmic origin was the most frequent diagnosis (53%), followed by reflex syncope (33%). Adherence to the guidelines was less than satisfactory-measurement of blood pressure in an upright position, carotid sinus massage, exercise testing, and electrophysiological study were underused, whereas prolonged ECG monitoring and neurological consultations were overused. Unexplained syncope had 58 (9%) patients, and 42 (72%) of them had indication for ILR which accounts for 6% of the whole study population. The calculated need for ILR was 222 implants/million inhabitants/year. CONCLUSION: Patients with syncope admitted to the tertiary electrophysiology cardiac centres are a highly selected group of patients with syncope and differ in their characteristics as well as underlying diseases to those managed at general hospitals, outpatient clinics, or special syncope units. In Poland, the adherence to the published guidelines is far from satisfactory. At least 6% of all consecutive patients with syncope are candidates for ILR insertion.


Subject(s)
Registries , Syncope/diagnosis , Syncope/epidemiology , Adult , Aged , Blood Pressure/physiology , Cardiac Electrophysiology , Electrocardiography , Female , Guideline Adherence , Hospitals, General , Humans , Male , Middle Aged , Pacemaker, Artificial , Poland/epidemiology , Prospective Studies , Retrospective Studies , Syncope/physiopathology
20.
Dysphagia ; 25(1): 66-9, 2010 Mar.
Article in English | MEDLINE | ID: mdl-19653039

ABSTRACT

We report a novel technique for diagnosing a new cause of esophageal dysphagia in a patient without organic heart and esophageal disease. A coincidence between intermittent esophageal dysphagia and cardiac arrhythmia, frequent premature ventricular complexes (PVC) were confirmed by clinical observation, simultaneous ECG monitoring, and motility study. High-resolution esophageal manometry (HRM) revealed abnormal peristaltic waves only during frequent PVC. Abnormal peristaltic waves and PVC disappeared simultaneously and completely within 15 min after intravenous infusion of antiarrhythmic agent (140 mg propafenone). Oral treatment with antiarrhythmic drugs was not tolerated or ineffective. Complete remission of PVC and dysphagia was achieved immediately after radiofrequency catheter ablation of arrhythmogenic focus located in the right ventricular outflow tract. This case demonstrates a new technique for the management of a syndrome called "PVC-associated dysphagia" that can be mediated by cardioesophageal reflex. Interdisciplinary cooperation and simultaneous HRM with ECG monitoring may confirm the diagnosis and guide effective treatment.


Subject(s)
Anti-Arrhythmia Agents/therapeutic use , Deglutition Disorders/diagnosis , Deglutition Disorders/etiology , Electrocardiography , Manometry/instrumentation , Propafenone/therapeutic use , Ventricular Premature Complexes/complications , Ventricular Premature Complexes/prevention & control , Drug Monitoring , Female , Humans , Middle Aged , Ventricular Premature Complexes/physiopathology
SELECTION OF CITATIONS
SEARCH DETAIL