Microsc Microanal ; 30(3): 466-475, 2024 Jul 04.
Article in English | MEDLINE | ID: mdl-38841834

ABSTRACT

Kingham [(1982). The post-ionization of field evaporated ions: A theoretical explanation of multiple charge states. Surf Sci116(2), 273-301] provided equations for the probability of observing higher charge states in atom probe tomography (APT) experiments. These "Kingham curves" have wide application in APT, but cannot be analytically transformed to provide the electric field in terms of the easily measured charge state ratio (CSR). Here we provide a numerical scheme for the calculation of Kingham curves and the variation in electric field with CSR. We find the variation in electric field with CSR is well described by a simple two- or three-parameter equation, and the model is accurate to most elements and charge states. The model is applied to experimental APT data of pure aluminium and a microalloyed steel, demonstrating that the methods described in this work can be easily applied to a variety of APT problems to understand electric field variations.

2.
Microsc Microanal ; 2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38833315

ABSTRACT

Cryogenic atom probe tomography (cryo-APT) is being developed to enable nanoscale compositional analyses of frozen liquids. Yet, the availability of readily available substrates that allow for the fixation of liquids while providing sufficient strength to their interface is still an issue. Here, we propose the use of 1-2-µm-thick binary alloy film of gold-silver sputtered onto flat silicon, with sufficient adhesion without an additional layer. Through chemical dealloying, we successfully fabricate a nanoporous substrate, with an open-pore structure, which is mounted on a microarray of Si posts by lift-out in the focused-ion beam system, allowing for cryogenic fixation of liquids. We present cryo-APT results obtained after cryogenic sharpening, vacuum cryo-transfer, and analysis of pure water on the top and inside the nanoporous film. We demonstrate that this new substrate has the requisite characteristics for facilitating cryo-APT of frozen liquids, with a relatively lower volume of precious metals. This complete workflow represents an improved approach for frozen liquid analysis, from preparation of the films to the successful fixation of the liquid in the porous network, to cryo-APT.

3.
Microsc Microanal ; 29(3): 890-899, 2023 Jun 09.
Article in English | MEDLINE | ID: mdl-37749684

ABSTRACT

The developing flexible ultrathin glass for use in foldable displays has attracted widespread attention as an alternative to rigid electronic smartphones. However, the detailed compositional effects of chemically strengthened glass are not well understood. Moreover, the spatially resolved chemistry and depth of the compression layer of tempered glass are far from clear. In this study, commonly used X-ray spectroscopy techniques and atom probe tomography (APT) were used comparatively to investigate the distribution of constituent elements in two representative smartphone glass samples: non- and chemically tempered. APT has enabled sub-nanoscale analyses of alkali metals (Li, Na, K, and Ca) and this demonstrates that APT can be considered as an alternative technique for imaging the chemical distribution in glass for mobile applications.

4.
Microsc Microanal ; 29(3): 1077-1086, 2023 Jun 09.
Article in English | MEDLINE | ID: mdl-37749678

ABSTRACT

Chemically resolved atomic resolution imaging can give fundamental information about material properties. However, even today, a technique capable of such achievement is still only an ambition. Here, we take further steps in developing the analytical field ion microscopy (aFIM), which combines the atomic spatial resolution of field ion microscopy (FIM) with the time-of-flight spectrometry of atom probe tomography (APT). To improve the performance of aFIM that are limited in part by a high level of background, we implement bespoke flight path time-of-flight corrections normalized by the ion flight distances traversed in electrostatic simulations modeled explicitly for an atom probe chamber. We demonstrate effective filtering in the field evaporation events upon spatially and temporally correlated multiples, increasing the mass spectrum's signal-to-background. In an analysis of pure tungsten, mass peaks pertaining to individual W isotopes can be distinguished and identified, with the signal-to-background improving by three orders of magnitude over the raw data. We also use these algorithms for the analysis of a CoTaB amorphous film to demonstrate application of aFIM beyond pure metals and binary alloys. These approaches facilitate elemental identification of the FIM-imaged surface atoms, making analytical FIM more precise and reliable.

5.
J Am Chem Soc ; 144(2): 987-994, 2022 Jan 19.
Article in English | MEDLINE | ID: mdl-34982554

ABSTRACT

Metal nanogels combine a large surface area, a high structural stability, and a high catalytic activity toward a variety of chemical reactions. Their performance is underpinned by the atomic-level distribution of their constituents, yet analyzing their subnanoscale structure and composition to guide property optimization remains extremely challenging. Here, we synthesized Pd nanogels using a conventional wet chemistry route, and a near-atomic-scale analysis reveals that impurities from the reactants (Na and K) are integrated into the grain boundaries of the poly crystalline gel, typically loci of high catalytic activity. We demonstrate that the level of impurities is controlled by the reaction condition. Based on ab initio calculations, we provide a detailed mechanism to explain how surface-bound impurities become trapped at grain boundaries that form as the particles coalesce during synthesis, possibly facilitating their decohesion. If controlled, impurity integration into grain boundaries may offer opportunities for designing new nanogels.

6.
Microsc Microanal ; : 1-18, 2022 Jan 18.
Article in English | MEDLINE | ID: mdl-35039105

ABSTRACT

Imaging of liquids and cryogenic biological materials by electron microscopy has been recently enabled by innovative approaches for specimen preparation and the fast development of optimized instruments for cryo-enabled electron microscopy (cryo-EM). Yet, cryo-EM typically lacks advanced analytical capabilities, in particular for light elements. With the development of protocols for frozen wet specimen preparation, atom probe tomography (APT) could advantageously complement insights gained by cryo-EM. Here, we report on different approaches that have been recently proposed to enable the analysis of relatively large volumes of frozen liquids from either a flat substrate or the fractured surface of a wire. Both allowed for analyzing water ice layers which are several micrometers thick consisting of pure water, pure heavy water, and aqueous solutions. We discuss the merits of both approaches and prospects for further developments in this area. Preliminary results raise numerous questions, in part concerning the physics underpinning field evaporation. We discuss these aspects and lay out some of the challenges regarding the APT analysis of frozen liquids.

7.
Microsc Microanal ; : 1-11, 2021 Oct 20.
Article in English | MEDLINE | ID: mdl-34666868

ABSTRACT

Atom probe tomography (APT) is often introduced as providing "atomic-scale" mapping of the composition of materials and as such is often exploited to analyze atomic neighborhoods within a material. Yet quantifying the actual spatial performance of the technique in a general case remains challenging, as it depends on the material system being investigated as well as on the specimen's geometry. Here, by using comparisons with field-ion microscopy experiments, field-ion imaging and field evaporation simulations, we provide the basis for a critical reflection on the spatial performance of APT in the analysis of pure metals, low alloyed systems and concentrated solid solutions (i.e., akin to high-entropy alloys). The spatial resolution imposes strong limitations on the possible interpretation of measured atomic neighborhoods, and directional neighborhood analyses restricted to the depth are expected to be more robust. We hope this work gets the community to reflect on its practices, in the same way, it got us to reflect on our work.

8.
Microsc Microanal ; : 1-9, 2021 Sep 03.
Article in English | MEDLINE | ID: mdl-34474700

ABSTRACT

Three-dimensional field ion microscopy is a powerful technique to analyze material at a truly atomic scale. Most previous studies have been made on pure, crystalline materials such as tungsten or iron. In this article, we study more complex materials, and we present the first images of an amorphous sample, showing the capability to visualize the compositional fluctuations compatible with theoretical medium order in a metallic glass (FeBSi), which is extremely challenging to observe directly using other microscopy techniques. The intensity of the spots of the atoms at the moment of field evaporation in a field ion micrograph can be used as a proxy for identifying the elemental identity of the imaged atoms. By exploiting the elemental identification and positioning information from field ion images, we show the capability of this technique to provide imaging of recrystallized phases in the annealed sample with a superior spatial resolution compared with atom probe tomography.

9.
Small ; 16(39): e2004400, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32885564

ABSTRACT

The properties of a material can be engineered by manipulating its atomic and chemical architecture. Nanoglasses which have been recently invented and comprise nanosized glassy particles separated by amorphous interfaces, have shown promising properties. A potential way to exploit the structural benefits of nanoglasses and of nanocrystalline materials is to optimize the composition to obtain crystals forming within the glassy particles. Here, a metastable Fe-10 at% Sc nanoglass is synthesized. A complex hierarchical microstructure is evidenced experimentally at the atomic scale. This bulk material comprises grains of a Fe90 Sc10 amorphous matrix separated by an amorphous interfacial network enriched and likely stabilized by hydrogen, and property-enhancing pure-Fe nanocrystals self-assembled within the matrix. This composite structure leads a yield strength above 2.5 GPa with an exceptional quasi-homogeneous plastic flow of more than 60% in compression. This work opens new pathways to design materials with even superior properties.

10.
Microsc Microanal ; 26(6): 1133-1146, 2020 Dec.
Article in English | MEDLINE | ID: mdl-33176891

ABSTRACT

Atom probe tomography (APT) is particularly suited for the analysis of nanoscale microstructural features in metallic alloys. APT has become important in the quantitative assessment at high spatial resolution of light elements, which are notoriously difficult to analyze by electron- or X-ray-based techniques. These control the physical properties of high-strength materials and semiconductors. However, the mass spectrometer of state-of-the-art commercial atom probes with the highest spatial precision and detection efficiency are optimized for elements with mass-to-charge ratios corresponding to Fe and neighboring elements. Little is known on the theoretical performances for light elements. Here, we discuss the theoretical instrumental performance of one such instrument using accurate three-dimensional transient electrostatic simulations in a time-varying field approach. We compare the simulations to experimental measurements obtained on an FeBSi bulk-metallic glass. Dynamics effects during the ion's flight are revealed when examining multi-hit mass-to-charge correlations, and we demonstrate their influence on the mass resolution. The model reveals significant differences in ion projection as a function of the mass. We discuss how these chromatic aberrations affect the spatial precision. This approach shows that by tuning the shape of the voltage pulses used to trigger field evaporation, minimizing the influence of these detrimental dynamic effects is possible.

11.
Angew Chem Int Ed Engl ; 59(14): 5651-5655, 2020 Mar 27.
Article in English | MEDLINE | ID: mdl-31922307

ABSTRACT

The incorporation of impurities during the chemical synthesis of nanomaterials is usually uncontrolled and rarely reported because of the formidable challenge in measuring trace amounts of often light elements with sub-nanometer spatial resolution. And yet, these foreign elements (introduced by doping, for example) influence functional properties. We demonstrate how the hydrothermal growth and a partial reduction reaction on hollow TiO2 nanowires leads to the introduction of parts per millions of boron, sodium, and nitrogen. This doping explains the presence of oxygen vacancies and reduced Ti states at the surface, which enhance the functional properties of TiO2 . Our results were obtained on model metal oxide nanomaterials and they shed light on a general process that leads to the uncontrolled incorporation of trace impurities in TiO2 , thereby, having a strong effect on applications in energy-harvesting.

12.
Microsc Microanal ; 25(2): 301-308, 2019 04.
Article in English | MEDLINE | ID: mdl-30714566

ABSTRACT

Although atom probe tomography (APT) reconstructions do not directly influence the local elemental analysis, any structural inferences from APT volumes demand a reliable reconstruction of the point cloud. Accurate estimation of the reconstruction parameters is crucial to obtain reliable spatial scaling. In the current work, a new automated approach of calibrating atom probe reconstructions is developed using only one correlative projection electron microscopy (EM) image. We employed an algorithm that implements a 2D cross-correlation of microstructural features observed in both the APT reconstructions and the corresponding EM image. We apply this protocol to calibrate reconstructions in a Cu(In,Ga)Se2-based semiconductor and in a Co-based superalloy. This work enables us to couple chemical precision to structural information with relative ease.

13.
Microsc Microanal ; 25(2): 481-488, 2019 04.
Article in English | MEDLINE | ID: mdl-30853034

ABSTRACT

Analysis and understanding of the role of hydrogen in metals is a significant challenge for the future of materials science, and this is a clear objective of recent work in the atom probe tomography (APT) community. Isotopic marking by deuteration has often been proposed as the preferred route to enable quantification of hydrogen by APT. Zircaloy-4 was charged electrochemically with hydrogen and deuterium under the same conditions to form large hydrides and deuterides. Our results from a Zr hydride and a Zr deuteride highlight the challenges associated with accurate quantification of hydrogen and deuterium, in particular associated with the overlap of peaks at a low mass-to-charge ratio and of hydrogen/deuterium containing molecular ions. We discuss possible ways to ensure that appropriate information is extracted from APT analysis of hydrogen in zirconium alloy systems that are important for nuclear power applications.

15.
Adv Sci (Weinh) ; 10(24): e2300626, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37290039

ABSTRACT

Gas-solid reactions are important for many redox processes that underpin the energy and sustainability transition. The specific case of hydrogen-based iron oxide reduction is the foundation to render the global steel industry fossil-free, an essential target as iron production is the largest single industrial emitter of carbon dioxide. This perception of gas-solid reactions has not only been limited by the availability of state-of-the-art techniques which can delve into the structure and chemistry of reacted solids, but one continues to miss an important reaction partner that defines the thermodynamics and kinetics of gas phase reactions: the gas molecules. In this investigation, cryogenic-atom probe tomography is used to study the quasi in situ evolution of iron oxide in the solid and gas phases of the direct reduction of iron oxide by deuterium gas at 700°C. So far several unknown atomic-scale characteristics are observed, including, D2 accumulation at the reaction interface; formation of a core (wüstite)-shell (iron) structure; inbound diffusion of D through the iron layer and partitioning of D among phases and defects; outbound diffusion of oxygen through the wüstite and/or through the iron to the next free available inner/outer surface; and the internal formation of heavy nano-water droplets at nano-pores.

16.
Nat Commun ; 14(1): 7410, 2023 Nov 16.
Article in English | MEDLINE | ID: mdl-37973821

ABSTRACT

Chemical short-range order (CSRO) refers to atoms of specific elements self-organising within a disordered crystalline matrix to form particular atomic neighbourhoods. CSRO is typically characterized indirectly, using volume-averaged or through projection microscopy techniques that fail to capture the three-dimensional atomistic architectures. Here, we present a machine-learning enhanced approach to break the inherent resolution limits of atom probe tomography enabling three-dimensional imaging of multiple CSROs. We showcase our approach by addressing a long-standing question encountered in body-centred-cubic Fe-Al alloys that see anomalous property changes upon heat treatment. We use it to evidence non-statistical B2-CSRO instead of the generally-expected D03-CSRO. We introduce quantitative correlations among annealing temperature, CSRO, and nano-hardness and electrical resistivity. Our approach is further validated on modified D03-CSRO detected in Fe-Ga. The proposed strategy can be generally employed to investigate short/medium/long-range ordering phenomena in different materials and help design future high-performance materials.

17.
Microsc Microanal ; 18(2): 359-64, 2012 Apr.
Article in English | MEDLINE | ID: mdl-22300727

ABSTRACT

Atom probe tomography (APT) provides three-dimensional analytical imaging of materials with near-atomic resolution using pulsed field evaporation. The processes of field evaporation can cause atoms to be placed at positions in the APT reconstruction that can deviate slightly from their original site in the material. Here, we describe and model one such process--that of preferential retention of solute atoms in multicomponent systems. Based on relative field evaporation probabilities, we calculate the point spread function for the solute atom distribution in the "z," or in-depth direction, and use this to extract more accurate solute concentration profiles.

18.
PLoS One ; 17(2): e0262543, 2022.
Article in English | MEDLINE | ID: mdl-35139091

ABSTRACT

Numerous metallurgical and materials science applications depend on quantitative atomic-scale characterizations of environmentally-sensitive materials and their transient states. Studying the effect upon materials subjected to thermochemical treatments in specific gaseous atmospheres is of central importance for specifically studying a material's resistance to certain oxidative or hydrogen environments. It is also important for investigating catalytic materials, direct reduction of an oxide, particular surface science reactions or nanoparticle fabrication routes. This manuscript realizes such experimental protocols upon a thermochemical reaction chamber called the "Reacthub" and allows for transferring treated materials under cryogenic & ultrahigh vacuum (UHV) workflow conditions for characterisation by either atom probe or scanning Xe+/electron microscopies. Two examples are discussed in the present study. One protocol was in the deuterium gas charging (25 kPa D2 at 200°C) of a high-manganese twinning-induced-plasticity (TWIP) steel and characterization of the ingress and trapping of hydrogen at various features (grain boundaries in particular) in efforts to relate this to the steel's hydrogen embrittlement susceptibility. Deuterium was successfully detected after gas charging but most contrast originated from the complex ion FeOD+ signal and the feature may be an artefact. The second example considered the direct deuterium reduction (5 kPa D2 at 700°C) of a single crystal wüstite (FeO) sample, demonstrating that under a standard thermochemical treatment causes rapid reduction upon the nanoscale. In each case, further studies are required for complete confidence about these phenomena, but these experiments successfully demonstrate that how an ex-situ thermochemical treatment can be realised that captures environmentally-sensitive transient states that can be analysed by atomic-scale by atom probe microscope.


Subject(s)
Gases
19.
J Mater Chem A Mater ; 10(9): 4926-4935, 2022 Mar 01.
Article in English | MEDLINE | ID: mdl-35341092

ABSTRACT

The worldwide development of electric vehicles as well as large-scale or grid-scale energy storage to compensate for the intermittent nature of renewable energy generation has led to a surge of interest in battery technology. Understanding the factors controlling battery capacity and, critically, their degradation mechanisms to ensure long-term, sustainable and safe operation requires detailed knowledge of their microstructure and chemistry, and their evolution under operating conditions, on the nanoscale. Atom probe tomography (APT) provides compositional mapping of materials in three dimensions with sub-nanometre resolution, and is poised to play a key role in battery research. However, APT is underpinned by an intense electric field that can drive lithium migration, and many battery materials are reactive oxides, requiring careful handling and sample transfer. Here, we report on the analysis of both anode and cathode materials and show that electric-field driven migration can be suppressed by using shielding by embedding powder particles in a metallic matrix or by using a thin conducting surface layer. We demonstrate that for a typical cathode material, cryogenic specimen preparation and transport under ultra-high vacuum leads to major delithiation of the specimen during the analysis. In contrast, the transport of specimens through air enables the analysis of the material. Finally, we discuss the possible physical underpinnings and discuss ways forward to enable shielding from the electric field, which helps address the challenges inherent to the APT analysis of battery materials.

20.
Microsc Microanal ; 17(2): 226-39, 2011 Apr.
Article in English | MEDLINE | ID: mdl-21382222

ABSTRACT

Atom probe tomography (APT) represents a significant step toward atomic resolution microscopy, analytically imaging individual atoms with highly accurate, though imperfect, chemical identity and three-dimensional (3D) positional information. Here, a technique to retrieve crystallographic information from raw APT data and restore the lattice-specific atomic configuration of the original specimen is presented. This lattice rectification technique has been applied to a pure metal, W, and then to the analysis of a multicomponent Al alloy. Significantly, the atoms are located to their true lattice sites not by an averaging, but by triangulation of each particular atom detected in the 3D atom-by-atom reconstruction. Lattice rectification of raw APT reconstruction provides unprecedented detail as to the fundamental solute hierarchy of the solid solution. Atomic clustering has been recognized as important in affecting alloy behavior, such as for the Al-1.1 Cu-1.7 Mg (at. %) investigated here, which exhibits a remarkable rapid hardening reaction during the early stages of aging, linked to clustering of solutes. The technique has enabled lattice-site and species-specific radial distribution functions, nearest-neighbor analyses, and short-range order parameters, and we demonstrate a characterization of solute-clustering with unmatched sensitivity and precision.

SELECTION OF CITATIONS