Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 28
Filter
1.
BMC Cancer ; 22(1): 570, 2022 May 21.
Article in English | MEDLINE | ID: mdl-35597921

ABSTRACT

BACKGROUND/AIM: To develop and validate a nebulizer device for anti-cancer research on pressurized intraperitoneal aerosol supply in a preclinical peritoneal metastases (PM) rat model. MATERIAL AND METHODS: For aerosol generation, an ultrasonic nebulizer (USN) was modified. Aerosol analyses were performed ex-vivo by laser diffraction spectrometry (LDS). Intraperitoneal (IP) 99mtechnetium sodium pertechnetate (99mTc) aerosol distribution and deposition were quantified by in-vivo single photon emission computed tomography (SPECT/CT) and compared to liquid IP instillation of equivalent volume/doses of 99mTc with and without capnoperitoneum. PM was induced by IP injection of HCT116-Luc2 human colon cancer cells in immunosuppressed RNU rats. Tumor growth was monitored by bioluminescence imaging (BLI), 18F-FDG positron emission tomography (PET) and tissues examination at necropsy. RESULTS: The USN was able to establish a stable and reproducible capnoperitoneum at a pressure of 8 to 10 mmHg. LDS showed that the USN provides a polydisperse and monomodal aerosol with a volume-weighted diameter of 2.6 µm. At a CO2 flow rate of 2 L/min with an IP residence time of 3.9 s, the highest drug deposition efficiency was found to be 15 wt.-%. In comparison to liquid instillation, nebulization showed the most homogeneous IP spatial drug deposition. Compared to BLI, 18F-FDG-PET was more sensitive to detect smaller PM nodules measuring only 1-2 mm in diameter. BLI, 18F-FDG PET and necropsy analyses showed relevant PM in all animals. CONCLUSIONS: The USN together with the PM rat model are suitable for robust and species-specific preclinical pharmacological studies regarding intraperitoneal delivery of pressurized aerosolized drugs and cancer research.


Subject(s)
Colonic Neoplasms , Peritoneal Neoplasms , Aerosols , Animals , Colonic Neoplasms/diagnostic imaging , Colonic Neoplasms/drug therapy , Fluorodeoxyglucose F18 , Humans , Nebulizers and Vaporizers , Peritoneal Neoplasms/diagnostic imaging , Peritoneal Neoplasms/secondary , Rats
2.
Surg Endosc ; 31(4): 1778-1784, 2017 04.
Article in English | MEDLINE | ID: mdl-27631320

ABSTRACT

BACKGROUND: Pressurized intraperitoneal aerosol chemotherapy (PIPAC) is gaining acceptance in clinical practice, but detailed information about the microinjection pump (MIP®), the generated aerosol and drug distribution is missing. ANALYTICAL METHODS: Ex vivo granulometric analyses by means of laser diffraction spectrometry were performed for MIP® aerosol characterization. Beside the standard operation conditions, the impact of the volumetric liquid flow rate on the aerosol characteristics was investigated with different liquids. Granulometric results as well as the local drug distribution were verified by ex vivo gravimetric analyses. On the basis of determined MIP® characteristics, the aerosol droplet size, which is necessary for a homogenous intra-abdominal drug distribution, was calculated. RESULTS: Granulometric analyses showed that the MIP® aerosol consists of a bimodal volume-weighted particle size distribution (PSD3) with a median droplet diameter of x 50,3 = 25 µm. Calculations reveal that the droplet size for a homogenous intra-abdominal drug distribution during PIPAC therapy should be below 1.2 µm. We show that >97.5 vol% of the aerosolized liquid is delivered as droplets with ≥3 µm in diameter, which are primarily deposited on the surface beneath the MIP® by gravitational settling and inertial impaction. These findings were confirmed by ex vivo gravimetric analyses, where more than 86.0 vol% of the aerosolized liquid was deposited within a circular area with a diameter of 15 cm. CONCLUSIONS: The granulometric aerosol properties, as well as the aerodynamic conditions achieved by standard MIP® operation, do not support the idea of widespread or homogenous drug distribution in the abdominal cavity.


Subject(s)
Aerosols/administration & dosage , Infusion Pumps , Microinjections/instrumentation , Aerosols/chemistry , Humans , In Vitro Techniques , Injections, Intraperitoneal , Pressure
3.
J Environ Manage ; 157: 230-7, 2015 Jul 01.
Article in English | MEDLINE | ID: mdl-25910977

ABSTRACT

Nanomaterials are commonly used in everyday life products and during their life cycle they can be released into the environment. Soils and sediments are estimated as significant sinks for those nanomaterials. To investigate and assess the behaviour of nanomaterials in soils and sediments standardized test methods are needed. In this study the applicability of two existing international standardized test guidelines for the testing of nanomaterials, OECD TG 106 "Adsorption/Desorption using a Bath Equilibrium Method" and the OECD TG 312 "Leaching in Soil Columns", were investigated. For the study one coated and two uncoated TiO2 nanomaterials were used, respectively. The results indicate that the OECD TG 106 is not applicable for nanomaterials. However, the test method according to OECD TG 312 was found to be applicable if nano-specific adaptations are applied. The mobility investigations of the OECD TG 312 indicated a material-dependent mobility of the nanomaterials, which in some cases may lead to an accumulation in the upper soil layers. Whereas no significant transport was observed for the uncoated materials for the double-coated material (coating with dimethicone and aluminiumoxide) a significant transport was detected and attributed to the coating.


Subject(s)
Soil Pollutants/chemistry , Titanium/chemistry , Environmental Policy , Humans , Nanostructures/chemistry , Organisation for Economic Co-Operation and Development , Toxicity Tests/standards
4.
Toxicol Lett ; 2024 Feb 22.
Article in English | MEDLINE | ID: mdl-38401876

ABSTRACT

Reproducible aerosol generation in combination with stable aerosol properties are essential prerequisites for compliant performance of acute or repeated inhalation toxicity tests of particulate materials according to OECD TG 403, 436, 412, or 413. A frequent problem of powder aerosol generation is the formation of coarse agglomerates with low shear resistance, which are beyond the tolerable size range but not detected by the prescribed aerodynamic measurement techniques by cascade impactor as the measurement conditions cause a disintegration into smaller fragments. But such agglomerates are observed during the transport to the inhalation chambers. These effects particularly apply to high mass concentrations and low-density powders, i.e., pyrogenic oxides. This study describes the transport influence in the airflow on the change of powder aerosols and on their respirability. A simplified short tube set-up was developed for the aerosol transport pre-tests, which allows the determination of the optimal aerosol formation conditions for the inhalation tests. The particles were measured with low shear using laser diffraction measurement or optical particle counters. The calculation of the aerodynamic particle sizes prescribed in the guidelines requires knowledge of the effective particle density of the porous aerosol particles. A practicable method for determining these is presented and described. In the outlook, first low concentration measurements show that clear agglomeration effects can also occur at particle concentrations around 20 mg/m³.

5.
Toxicol Lett ; 2024 Mar 20.
Article in English | MEDLINE | ID: mdl-38518988

ABSTRACT

High concentrations of low-density particles may cause effects in acute inhalation toxicity studies which can be easily underestimated or misinterpreted following strictly the OECD TG 436, i.e., limited parameters as mortality and gross lesions will be evaluated only. Seven particle types (synthetic amorphous silica (SAS) HMDZ-SAS, silica gel, pyrogenic SAS, and precipitated SAS, calcium carbonate, aluminum oxide pyrogenic alumina, organic red pigment) were chosen at the highest technically feasible concentration of approximately 500 mg/m3 for acute inhalation studies with an expanded endpoint setup. Therefore additional parameters and a thorough histopathological evaluation of an extensive set of organs, including the respiratory tract emphasizing the nasal cavities were added. Six Crl:WI rats per study were exposed for four hours from which three animals were sacrificed after 24 hours and three animals after 14 days. HMDZ-SAS caused early death in all animals due to blockage of the nasal passages caused by its hydrophobicity. For all other Si-containing compounds, histology revealed minor inflammatory and reactive lesions in lungs after 24 hours that were still present after 14 days, except in silica gel-treated animals. After 14 days, for pyrogenic SAS, precipitated SAS, and pyrogenic alumina, granulomas formed in the BALT and lung-associated lymph nodes. In contrast, the calcium carbonate induced almost no findings, and the red pigment (also tested for the additional dose of 1000 mg/m3) stuck partially to the nasal mucosa without causing pathological damage and partly entered the lungs without showing any adverse effects. The results of the present study highlight the advantage of improving the rather simple study design of acute inhalation studies by implementing an extended study design.

6.
Environ Toxicol Pharmacol ; 98: 104079, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36796551

ABSTRACT

Building demolition following domestic fires or abrasive processing after thermal recycling can release particles harmful for the environment and human health. To mimic such situations, particles release during dry-cutting of construction materials was investigated. A reinforcement material consisting of carbon rods (CR), carbon concrete composite (C³) and thermally treated C³ (ttC³) were physicochemically and toxicologically analyzed in monocultured lung epithelial cells, and co-cultured lung epithelial cells and fibroblasts at the air-liquid interface. C³ particles reduced their diameter to WHO fibre dimensions during thermal treatment. Caused by physical properties or by polycyclic aromatic hydrocarbons and bisphenol A found in the materials, especially the released particles of CR and ttC³ induced an acute inflammatory response and (secondary) DNA damage. Transcriptome analysis indicated that CR and ttC³ particles carried out their toxicity via different mechanisms. While ttC³ affected pro-fibrotic pathways, CR was mostly involved in DNA damage response and in pro-oncogenic signaling.


Subject(s)
Air Pollutants , Polycyclic Aromatic Hydrocarbons , Humans , Particulate Matter/analysis , Air Pollutants/analysis , Particle Size , Lung , Epithelial Cells , Polycyclic Aromatic Hydrocarbons/analysis , Inflammation/metabolism , DNA Damage , Construction Materials , Fibroblasts
7.
Toxicol Lett ; 2023 Feb 16.
Article in English | MEDLINE | ID: mdl-36806657

ABSTRACT

Inhalation toxicity testing of particulate materials is mandated for classification. According to CLP, particulate materials should be tested as marketed and many particulate materials are marketed as non-respirable particles. However, OECD TG 413 requires exposure to particle sizes that are respirable and reach the alveoli. The requirement for exposure of rats to respirable particles is thus in contrast to CLP and requires the application of high shear forces. The exposure to artificially small particles causes a number of issues that hamper the interpretation of the results of the testing. These issues are aerosol altering in the exposure system, assessment of the adversity of the inflammatory lung responses, inclusion of recovery groups, and extrapolation of the results to humans exposed under occupational condition. In addition, effects of many particulate materials after testing according to OECD 413 are not intrinsic properties, but a general reaction of the lung to the deposited material, show very similar NOAECs for chemical diverse materials, and often are completely reversible.

8.
Front Public Health ; 10: 907202, 2022.
Article in English | MEDLINE | ID: mdl-35784249

ABSTRACT

Low density powders have a bulk density of less than 100 kg/m3 and are produced technically by flame pyrolysis of silicon tetrachloride (pyrogenic powders such as pyrogenic silica) or wet-chemically by sol-gel processes (e.g. silica-gel) or precipitation reactions using sodium silicate solution and a mineral acid. The transport and alteration behavior of aerosols from low density powders was investigated in a device for toxicological inhalation studies. The test conditions corresponded to those for acute toxicology studies according to OECD Guideline 436. The use of cascade impactors, required by guideline, has not proven successful for low density powders as the fragile agglomerate structures are destroyed during the measurement. As an alternative and non-invasive measurement method, laser diffraction spectroscopy has proved very successful in the present investigations. In particular, aerosols from pyrogenic powders of low density showed a distinctive tendency to re-agglomerate, especially at concentrations >500 mg/m3mm3. Investigation results indicate that aerosol particle size must be monitored over the entire acute inhalation test period for acute inhalation studies to be performed reliably.


Subject(s)
Silicon Dioxide , Administration, Inhalation , Aerosols/chemistry , Particle Size , Powders
9.
Front Public Health ; 10: 907078, 2022.
Article in English | MEDLINE | ID: mdl-35719607

ABSTRACT

The aim of the present study was to understand the mechanism of lethality associated with high dose inhalation of a low-density hydrophobic surface-treated SAS observed in some acute inhalation studies. It was demonstrated that physical obstruction of the upper respiratory tract (nasal cavities) caused the effects observed. Hydrophobic surface-treated SAS was inhaled (flow-past, nose-only) by six Wistar rats (three males and three females) in an acute toxicity study at a concentration of ~500 mg/m3 for an intended 4-hr exposure. Under the conditions of the test set-up, the concentration applied was found to be the highest that can be delivered to the test animal port without significant alteration of the aerosol size distribution over time. None of the test- material-exposed animals survived the planned observation time of 4 h; three animals died between 2 34 h after starting exposure and cessation of exposure at 3 14 h, two died after transfer to their cages and the remaining animal was sacrificed due to its poor condition and welfare considerations. Histology accomplished by energy dispersive X-ray (EDX) analysis demonstrated that test material particles agglomerated and formed a gel-like substrate that ultimately blocked the upper respiratory airways, which proved fatal for the rat as an obligatory nose breather. This observation is in line with the findings reported by Hofmann et al. showing a correlation between lethality and hydrophobicity determined by contact angle measurement. The aerosol characterizations associated with this study are provided in detail by Wessely et al.


Subject(s)
Inhalation Exposure , Silicon Dioxide , Aerosols , Animals , Asphyxia , Female , Hydrophobic and Hydrophilic Interactions , Inhalation Exposure/adverse effects , Inhalation Exposure/analysis , Male , Nasal Cavity/chemistry , Rats , Rats, Wistar , Silicon Dioxide/analysis , Silicon Dioxide/toxicity
10.
Part Fibre Toxicol ; 8: 22, 2011 Jul 27.
Article in English | MEDLINE | ID: mdl-21794132

ABSTRACT

Risk, associated with nanomaterial use, is determined by exposure and hazard potential of these materials. Both topics cannot be evaluated absolutely independently. Realistic dose concentrations should be tested based on stringent exposure assessments for the corresponding nanomaterial taking into account also the environmental and product matrix. This review focuses on current available information from peer reviewed publications related to airborne nanomaterial exposure. Two approaches to derive realistic exposure values are differentiated and independently presented; those based on workplace measurements and the others based on simulations in laboratories. An assessment of the current available workplace measurement data using a matrix, which is related to nanomaterials and work processes, shows, that data are available on the likelihood of release and possible exposure. Laboratory studies are seen as an important complementary source of information on particle release processes and hence for possible exposure. In both cases, whether workplace measurements or laboratories studies, the issue of background particles is a major problem. From this review, major areas for future activities and focal points are identified.


Subject(s)
Air Pollutants, Occupational/analysis , Nanoparticles/analysis , Occupational Exposure , Air Pollutants, Occupational/toxicity , Humans , Nanoparticles/toxicity , Occupational Exposure/adverse effects , Occupational Exposure/analysis , Particle Size , Time Factors , Workplace/standards
11.
Sci Rep ; 11(1): 21843, 2021 11 08.
Article in English | MEDLINE | ID: mdl-34750488

ABSTRACT

Pressurized Intraperitoneal Aerosol Chemotherapy (PIPAC) is a promising approach with a high optimization potential for the treatment of peritoneal carcinomatosis. To study the efficacy of PIPAC and drugs, first rodent cancer models were developed. But inefficient drug aerosol supply and knowledge gaps concerning spatial drug distribution can limit the results based on such models. To study drug aerosol supply/deposition, computed tomography scans of a rat capnoperitoneum were used to deduce a virtual and a physical phantom of the rat capnoperitoneum (RCP). RCP qualification was performed for a specific PIPAC method, where the capnoperitoneum is continuously purged by the drug aerosol. In this context, also in-silico analyses by computational fluid dynamic modelling were conducted on the virtual RCP. The physical RCP was used for ex-vivo granulometric analyses concerning drug deposition. Results of RCP qualification show that aerosol deposition in a continuous purged rat capnoperitoneum depends strongly on the position of the inlet and outlet port. Moreover, it could be shown that the droplet size and charge condition of the drug aerosol define the deposition efficiency. In summary, the developed virtual and physical RCP enables detailed in-silico and ex-vivo analyses on drug supply/deposition in rodents.


Subject(s)
Antineoplastic Agents/administration & dosage , Peritoneal Neoplasms/drug therapy , Peritoneum/diagnostic imaging , Aerosols , Animals , Antineoplastic Agents/pharmacokinetics , Computer Simulation , Computer-Aided Design , Humans , Hydrodynamics , Injections, Intraperitoneal/instrumentation , Injections, Intraperitoneal/methods , Models, Animal , Peritoneal Neoplasms/diagnostic imaging , Peritoneal Neoplasms/metabolism , Peritoneum/metabolism , Phantoms, Imaging , Pressure , Rats , Tomography, X-Ray Computed , User-Computer Interface
12.
Ann Occup Hyg ; 54(6): 615-24, 2010 Aug.
Article in English | MEDLINE | ID: mdl-20696941

ABSTRACT

Nanoparticles are used in industrial and domestic applications to control customized product properties. But there are several uncertainties concerning possible hazard to health safety and environment. Hence, it is necessary to search for methods to analyze the particle release from typical application processes. Based on a survey of commercial sanding machines, the relevant sanding process parameters were employed for the design of a miniature sanding test setup in a particle-free environment for the quantification of the nanoparticle release into air from surface coatings. The released particles were moved by a defined airflow to a fast mobility particle sizer and other aerosol measurement equipment to enable the determination of released particle numbers additionally to the particle size distribution. First, results revealed a strong impact of the coating material on the swarf mass and the number of released particles.


Subject(s)
Air Pollutants, Occupational/chemistry , Dust/analysis , Nanoparticles/analysis , Research Design , Aerosols/analysis , Aerosols/chemistry , Air Pollutants, Occupational/analysis , Air Pollution, Indoor/statistics & numerical data , Equipment and Supplies , Ferric Compounds/analysis , Ferric Compounds/chemistry , Humans , Models, Chemical , Nanoparticles/chemistry , Nanoparticles/ultrastructure , Particle Size , Polyurethanes/analysis , Polyurethanes/chemistry , Reproducibility of Results , Risk Assessment , Surface Properties , Zinc Oxide/analysis , Zinc Oxide/chemistry
13.
J Am Coll Surg ; 231(6): 704-712, 2020 12.
Article in English | MEDLINE | ID: mdl-32891798

ABSTRACT

BACKGROUND: In the COVID-19 crisis, laparoscopic surgery is in focus as a relevant source of bioaerosol release. The efficacy of electrostatic aerosol precipitation (EAP) and continuous aerosol evacuation (CAE) to eliminate bioaerosols during laparoscopic surgery was verified. STUDY DESIGN: Ex-vivo laparoscopic cholecystectomies (LCs) were simulated ± EAP or CAE in Pelvitrainer equipped with swine gallbladders. Release of bioaerosols was initiated by performing high-frequency electrosurgery with a monopolar electro hook (MP-HOOK) force at 40 watts (MP-HOOK40) and 60 watts (MP-HOOK60), as well as by ultrasonic cutting (USC). Particle number concentrations (PNC) of arising aerosols were analyzed with a condensation particle counter (CPC). Aerosol samples were taken within the Pelvitrainer close to the source, outside the Pelvitrainer at the working trocar, and in the breathing zone of the surgeon. RESULTS: Within the Pelvitrainer, MP-HOOK40 (6.4 × 105 cm-3) and MP-HOOK60 (7.3 × 105 cm-3) showed significantly higher median PNCs compared to USC (4.4 × 105 cm-3) (p = 0.001). EAP led to a significant decrease of the median PNCs in all 3 groups. A high linear correlation with Pearson correlation coefficients of 0.852, 0.825, and 0.759 were observed by comparing MP-HOOK40 (± EAP), MP-HOOK60 (± EAP), and USC (± EAP), respectively. During ex-vivo LC and CAE, significant bioaerosol contaminations of the operating room occurred. Ex-vivo LC with EAP led to a considerable reduction of the bioaerosol concentration. CONCLUSIONS: EAP was found to be efficient for intraoperative bioaerosol elimination and reducing the risk of bioaerosol exposure for surgical staff.


Subject(s)
Aerosols , Cholecystectomy, Laparoscopic/methods , Electrosurgery/methods , Infection Control/methods , Infectious Disease Transmission, Patient-to-Professional/prevention & control , Models, Animal , Static Electricity , Aerosols/analysis , Air Microbiology , Animals , COVID-19/prevention & control , COVID-19/transmission , Cholecystectomy, Laparoscopic/instrumentation , Electrosurgery/instrumentation , In Vitro Techniques , Infection Control/instrumentation , Occupational Exposure/analysis , Occupational Exposure/prevention & control , Pilot Projects , Swine
14.
Light Sci Appl ; 9: 21, 2020.
Article in English | MEDLINE | ID: mdl-32128161

ABSTRACT

Light scattering is a fundamental property that can be exploited to create essential devices such as particle analysers. The most common particle size analyser relies on measuring the angle-dependent diffracted light from a sample illuminated by a laser beam. Compared to other non-light-based counterparts, such a laser diffraction scheme offers precision, but it does so at the expense of size, complexity and cost. In this paper, we introduce the concept of a new particle size analyser in a collimated beam configuration using a consumer electronic camera and machine learning. The key novelty is a small form factor angular spatial filter that allows for the collection of light scattered by the particles up to predefined discrete angles. The filter is combined with a light-emitting diode and a complementary metal-oxide-semiconductor image sensor array to acquire angularly resolved scattering images. From these images, a machine learning model predicts the volume median diameter of the particles. To validate the proposed device, glass beads with diameters ranging from 13 to 125 µm were measured in suspension at several concentrations. We were able to correct for multiple scattering effects and predict the particle size with mean absolute percentage errors of 5.09% and 2.5% for the cases without and with concentration as an input parameter, respectively. When only spherical particles were analysed, the former error was significantly reduced (0.72%). Given that it is compact (on the order of ten cm) and built with low-cost consumer electronics, the newly designed particle size analyser has significant potential for use outside a standard laboratory, for example, in online and in-line industrial process monitoring.

15.
Nanomaterials (Basel) ; 9(6)2019 May 31.
Article in English | MEDLINE | ID: mdl-31159329

ABSTRACT

Dynamic light scattering (DLS) is commonly used for the determination of average particle diameters and suspension stability and popular in academics and industry. However, DLS is not considered suitable for polydisperse samples. The presence of little quantities of micrometre particles in nano and submicrometre suspensions especially affect the reliability of DLS results. Microfiltration might be a suitable method for the removal of unwanted large particles. This study investigates the effect of microfiltration on the diameter distributions as measured by DLS. Polystyrene standards (40-900 nm diameter), and monomodal silica suspensions were filtered with polytetrafluoroethylene (PTFE) membranes (0.1-1.0 µm pore size) to investigate retention properties and grade efficiency. Non-ideal materials were used to prove the results. Experiments showed that a mono-exponential decay can be achieved by filtration. A size safety factor of at least three between labeled pore size and average diameter was found to keep separation as low as possible. Filtration in order to enhance DLS for particulate submicrometre materials was considered suitable for narrowly distributed coated titania and kaolin powder. In a regulatory context, this might have an impact on considering a substance false positive or false negative according to the European Commission (EC) recommendation of a definition of the term nanomaterial.

16.
Nanoscale ; 11(38): 17637-17654, 2019 Oct 03.
Article in English | MEDLINE | ID: mdl-31539006

ABSTRACT

The project nanoGRAVUR (BMBF, 2015-2018) developed a framework for grouping of nanomaterials. Different groups may result for each of the three distinct perspectives of occupational, consumer and environmental safety. The properties, methods and descriptors are harmonised between the three perspectives and are based on: Tier 1 intrinsic physico-chemical properties (what they are) or GHS classification of the non-nano-form (human tox, ecotox, physical hazards); Tier 2 extrinsic physico-chemical properties, release from nano-enabled products, in vitro assays with cells (where they go; what they do); Tier 3 case-specific tests, potentially in vivo studies to substantiate the similarity within groups or application-specific exposure testing. Amongst all properties, dissolution and transformation are least modulated by different nanoforms within one substance, whereas dustiness, dispersion stability, abiotic and especially in vitro surface reactivity vary more often between different nanoforms. The methods developed or selected by nanoGRAVUR fill several gaps highlighted in the ProSafe reviews, and are useful to implement (i) the concept of nanoforms of the European Chemicals Agency (ECHA) and (ii) the concept of discrete forms of the United States Environmental Protection Agency (EPA). One cannot assess the significance of a dissimilarity, if the dynamic range of that property is unknown. Benchmark materials span dynamic ranges that enable us to establish bands, often with order-of-magnitude ranges. In 34 case studies we observed high biological similarity within each substance when we compared different (nano)forms of SiO2, BaSO4, kaolin, CeO2, ZnO, organic pigments, especially when we compared forms that are all untreated on the surface. In contrast, different Fe2O3 or TiO2 (nano)forms differ more significantly. The same nanoforms were also integrated in nano-enabled products (NEPs) for automotive coatings, clinker-reduced cements, cosmetic sunscreen, and lightweight polymers.

17.
Nanomaterials (Basel) ; 8(7)2018 Jun 21.
Article in English | MEDLINE | ID: mdl-29933581

ABSTRACT

The granulometric characterization of synthetic amorphous silica (SAS) nanomaterials (NMs) still demands harmonized standard operation procedures. SAS is produced as either precipitated, fumed (pyrogenic), gel and colloidal SAS and these qualities differ, among others, with respect to their state of aggregation and aggregate strength. The reproducible production of suspensions from SAS, e.g., for biological testing purposes, demands a reasonable amount of dispersing energy. Using materials representative for each of the types of SAS, we employed ultrasonic dispersing (USD) at energy densities of 8⁻1440 J/mL and measured resulting particle sizes by dynamic light scattering and laser diffraction. In this energy range, USD had no significant impact on particle size distributions of colloidal and gel SAS, but clearly decreased the particle size of precipitated and fumed SAS. For high energy densities, we observed a considerable contamination of SAS suspensions with metal particles caused by abrasion of the sonotrode’s tip. To avoid this problem, the energy density was limited to 270 J/mL and remaining coarse particles were removed with size-selective filtration. The ultrasonic dispersion of SAS at medium levels of energy density is suggested as a reasonable compromise to produce SAS suspensions for toxicological in vitro testing.

18.
Nanomaterials (Basel) ; 9(1)2018 Dec 22.
Article in English | MEDLINE | ID: mdl-30583541

ABSTRACT

Synthetic amorphous silica (SAS) constitute a large group of industrial nanomaterials (NM). Based on their different production processes, SAS can be distinguished as precipitated, fumed, gel and colloidal. The biological activity of SAS, e.g., cytotoxicity or inflammatory potential in the lungs is low but has been shown to depend on the particle size, at least for colloidal silica. Therefore, the preparation of suspensions from highly aggregated or agglomerated SAS powder materials is critical. Here we analyzed the influence of ultrasonic dispersion energy on the biologic activity of SAS using NR8383 alveolar macrophage (AM) assay. Fully characterized SAS (7 precipitated, 3 fumed, 3 gel, and 1 colloidal) were dispersed in H2O by stirring and filtering through a 5 µm filter. Aqueous suspensions were sonicated with low or high ultrasonic dispersion (USD) energy of 18 or 270 kJ/mL, respectively. A dose range of 11.25⁻90 µg/mL was administered to the AM under protein-free conditions to detect particle-cell interactions without the attenuating effect of proteins that typically occur in vivo. The release of lactate dehydrogenase (LDH), glucuronidase (GLU), and tumor necrosis factor α (TNF) were measured after 16 h. Hydrogen peroxide (H2O2) production was assayed after 90 min. The overall pattern of the in vitro response to SAS (12/14) was clearly dose-dependent, except for two SAS which showed very low bioactivity. High USD energy gradually decreased the particle size of precipitated, fumed, and gel SAS whereas the low adverse effect concentrations (LOECs) remained unchanged. Nevertheless, the comparison of dose-response curves revealed slight, but uniform shifts in EC50 values (LDH, and partially GLU) for precipitated SAS (6/7), gel SAS (2/3), and fumed SAS (3/3). Release of TNF changed inconsistently with higher ultrasonic dispersion (USD) energy whereas the induction of H2O2 was diminished in all cases. Electron microscopy and energy dispersive X-ray analysis showed an uptake of SAS into endosomes, lysosomes, endoplasmic reticulum, and different types of phagosomes. The possible effects of different uptake routes are discussed. The study shows that the effect of increased USD energy on the in vitro bioactivity of SAS is surprisingly small. As the in vitro response of AM to different SAS is highly uniform, the production process per se is of minor relevance for toxicity.

20.
Phys Rev E Stat Nonlin Soft Matter Phys ; 76(3 Pt 1): 031402, 2007 Sep.
Article in English | MEDLINE | ID: mdl-17930242

ABSTRACT

Pyrogenic silica is often used as a thickening agent in paints, pastes, adhesives, or resins. Other applications include, e.g., abrasives in chemical mechanical planarization in the microelectronics industry. In all these applications it is essential to control the state of dispersion. Sometimes, phase transitions from the liquid to the solid state are required while in other cases they have to be completely avoided for the whole shelf life. The nature and influencing parameters of the fluid-solid transition for pyrogenic silica have not been investigated so far. Most investigations deal with the phase transitions of small clay particles such as laponite. Here, we dedicate our interest to the behavior of pyrogenic silica suspensions with varying specific surface area and ionic background concentration. To get an impression of the phase transition behavior we compare our results to model laponite suspensions. We apply dynamic light scattering measurements in the backscattering regime to minimize multiple scattering contributions from concentrated pyrogenic silica suspensions. Further on we exert a decomposition of the measured autocorrelation functions into an ergodic and nonergodic contribution. The analysis of the ergodic spectrum yields two different gelation kinetics for both systems, laponite and pyrogenic silica. For laponite these are in accordance with earlier investigations. The kinetics depend on the ionic background and the solids content of the suspensions. Additionally, we used dynamic extinction spectroscopy to follow the phase transitions of pyrogenic silica on a macroscale.

SELECTION OF CITATIONS
SEARCH DETAIL