1.
Ultrasound Obstet Gynecol ; 60(1): 109-117, 2022 07.
Article in English | MEDLINE | ID: mdl-34826157

ABSTRACT

OBJECTIVE: Although fetal autopsy is generally recommended to confirm or refute the antemortem diagnosis, parental acceptance of the procedure has fallen over time, mainly due to its invasiveness. Contrast-enhanced microfocus CT (micro-CT) and high-field magnetic resonance imaging (HF-MRI, ≥ 3 Tesla) have both been suggested as non-invasive alternatives to conventional fetal autopsy for fetuses < 20 weeks of gestation. The aim of this study was to compare these two modalities in postmortem whole-body fetal imaging. METHODS: In this study, the imaging process and quality of micro-CT and HF-MRI were compared using both qualitative and quantitative assessments. For the qualitative evaluation, fetal anatomy experts scored 56 HF-MRI and 56 micro-CT images of four human fetuses aged 13-18 gestational weeks on two components: overall image quality and the ability to recognize and assess 21 anatomical structures. For the quantitative evaluation, participants segmented manually three organs with increasing complexity to assess interobserver variability. In addition, the signal-to-noise and contrast-to-noise ratios of five major organs were determined. RESULTS: Both imaging techniques were able to reach submillimeter voxel size. The highest resolution of micro-CT was 22 µm (isotropic), while the highest resolution of HF-MRI was 137 µm (isotropic). The qualitative image assessment form was sent to 45 fetal anatomy experts, of whom 36 (80%) responded. It was observed that micro-CT scored higher on all components of the qualitative assessment compared with HF-MRI. In addition, the quantitative assessment showed that micro-CT had lower interobserver variability and higher signal-to-noise and contrast-to-noise ratios. CONCLUSIONS: Our findings show that micro-CT outperforms HF-MRI in postmortem whole-body fetal imaging in terms of both quantitative and qualitative outcomes. Combined, these findings suggest that the ability to extract diagnostic information is greater when assessing micro-CT compared with HF-MRI images. We, therefore, believe that micro-CT is the preferred imaging modality as an alternative to conventional fetal autopsy for early gestation and is an indispensable tool in postmortem imaging services. © 2021 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Subject(s)
Fetus , Magnetic Resonance Imaging , Autopsy/methods , Female , Fetus/diagnostic imaging , Fetus/pathology , Gestational Age , Humans , Magnetic Resonance Imaging/methods , Pregnancy , X-Ray Microtomography/methods
2.
Eur Radiol ; 30(4): 2280-2292, 2020 Apr.
Article in English | MEDLINE | ID: mdl-31834508

ABSTRACT

BACKGROUND: MRI and CT have been extensively used to study fetal anatomy for research and diagnostic purposes, enabling minimally invasive autopsy and giving insight in human fetal development. Novel (contrast-enhanced) microfocus CT (micro-CT) and ultra-high-field (≥ 7.0 T) MRI (UHF-MRI) techniques now enable micron-level resolution that combats the disadvantages of low-field MRI and conventional CT. Thereby, they might be suitable to study fetal anatomy in high detail and, in time, contribute to the postmortem diagnosis of fetal conditions. OBJECTIVES: (1) To systematically examine the usability of micro-CT and UHF-MRI to study postmortem human fetal anatomy, and (2) to analyze factors that govern success at each step of the specimen preparation and imaging. METHOD: MEDLINE and EMBASE were systematically searched to identify publications on fetal imaging by micro-CT or UHF-MRI. Scanning protocols were summarized and best practices concerning specimen preparation and imaging were enumerated. RESULTS: Thirty-two publications reporting on micro-CT and UHF-MRI were included. The majority of the publications focused on imaging organs separately and seven publications focused on whole body imaging, demonstrating the possibility of visualization of small anatomical structures with a resolution well below 100 µm. When imaging soft tissues by micro-CT, the fetus should be stained by immersion in Lugol's staining solution. CONCLUSION: Micro-CT and UHF-MRI are both excellent imaging techniques to provide detailed images of gross anatomy of human fetuses. The present study offers an overview of the current best practices when using micro-CT and/or UHF-MRI to study fetal anatomy for clinical and research purposes. KEY POINTS: • Micro-CT and UHF-MRI can both be used to study postmortem human fetal anatomy for clinical and research purposes. • Micro-CT enables high-resolution imaging of fetal specimens in relatively short scanning time. However, tissue staining using a contrast solution is necessary to enable soft-tissue visualization. • UHF-MRI enables high-resolution imaging of fetal specimens, without the necessity of prior staining, but with the drawback of long scanning time.


Subject(s)
Fetus/diagnostic imaging , Magnetic Resonance Imaging/methods , X-Ray Microtomography/methods , Autopsy/methods , Humans , Whole Body Imaging
3.
NMR Biomed ; 31(10): e3932, 2018 10.
Article in English | MEDLINE | ID: mdl-29846986

ABSTRACT

This review on magnetic resonance elastography (MRE) of the breast provides an overview of available literature and describes current developments in the field of breast MRE, including new transducer technology for data acquisition and multi-frequency-derived power-law behaviour of tissue. Moreover, we discuss the future potential of breast MRE, which goes beyond its original application as an additional tool in differentiating benign from malignant breast lesions. These areas of ongoing and future research include MRE for pre-operative tumour delineation, staging, monitoring and predicting response to treatment, as well as prediction of the metastatic potential of primary tumours.


Subject(s)
Breast/diagnostic imaging , Elasticity Imaging Techniques , Magnetic Resonance Imaging , Elastic Modulus , Humans , Publications
4.
J Cardiovasc Magn Reson ; 19(1): 39, 2017 Mar 31.
Article in English | MEDLINE | ID: mdl-28359292

ABSTRACT

BACKGROUND: Time resolved 4D phase contrast (PC) cardiovascular magnetic resonance (CMR) in mice is challenging due to long scan times, small animal ECG-gating and the rapid blood flow and cardiac motion of small rodents. To overcome several of these technical challenges we implemented a retrospectively self-gated 4D PC radial ultra-short echo-time (UTE) acquisition scheme and assessed its performance in healthy mice by comparing the results with those obtained with an ECG-triggered 4D PC fast low angle shot (FLASH) sequence. METHODS: Cardiac 4D PC CMR images were acquired at 9.4 T in healthy mice using the proposed self-gated radial center-out UTE acquisition scheme (TE/TR of 0.5 ms/3.1 ms) and a standard Cartesian 4D PC imaging sequence (TE/TR of 2.1 ms/5.0 ms) with a four-point Hadamard flow encoding scheme. To validate the proposed UTE flow imaging technique, experiments on a flow phantom with variable pump rates were performed. RESULTS: The anatomical images and flow velocity maps of the proposed 4D PC UTE technique showed reduced artifacts and an improved SNR (left ventricular cavity (LV): 8.9 ± 2.5, myocardium (MC): 15.7 ± 1.9) compared to those obtained using a typical Cartesian FLASH sequence (LV: 5.6 ± 1.2, MC: 10.1 ± 1.4) that was used as a reference. With both sequences comparable flow velocities were obtained in the flow phantom as well as in the ascending aorta (UTE: 132.8 ± 18.3 cm/s, FLASH: 134.7 ± 13.4 cm/s) and pulmonary artery (UTE: 78.5 ± 15.4 cm/s, FLASH: 86.6 ± 6.2 cm/s) of the animals. Self-gated navigator signals derived from information of the oversampled k-space center were successfully extracted for all animals with a higher gating efficiency of time spent on acquiring gated data versus total measurement time (UTE: 61.8 ± 11.5%, FLASH: 48.5 ± 4.9%). CONCLUSIONS: The proposed self-gated 4D PC UTE sequence enables robust and accurate flow velocity mapping of the mouse heart in vivo at high magnetic fields. At the same time SNR, gating efficiency, flow artifacts and image quality all improved compared to the images obtained using the well-established, ECG-triggered, 4D PC FLASH sequence.


Subject(s)
Cardiac-Gated Imaging Techniques , Heart/diagnostic imaging , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging, Cine/methods , Animals , Artifacts , Blood Flow Velocity , Cardiac-Gated Imaging Techniques/instrumentation , Coronary Circulation , Electrocardiography , Heart Rate , Magnetic Resonance Imaging, Cine/instrumentation , Male , Mice, Inbred C57BL , Models, Animal , Phantoms, Imaging , Predictive Value of Tests , Reproducibility of Results , Time Factors
5.
Sci Rep ; 13(1): 3159, 2023 02 23.
Article in English | MEDLINE | ID: mdl-36823242

ABSTRACT

Distal radio-ulnar joint (DRUJ) motion analysis using dynamic CT is gaining popularity. Following scanning and segmentation, 3D bone models are registered to (4D-)CT target frames. Imaging errors like low signal-to-noise ratio (SNR), limited Z-coverage and motion artefacts influence registration, causing misinterpretation of joint motion. This necessitates quantification of the methodological error. A cadaver arm and dynamic phantom were subjected to multiple 4D-CT scans, while varying tube charge-time product and phantom angular velocity, to evaluate the effects of SNR and motion artefacts on registration accuracy and precision. 4D-CT Z-coverage is limited by the scanner. To quantify the effects of different Z-coverages on registration accuracy and precision, 4D-CT was simulated by acquiring multiple spiral 3D-CT scans of the cadaver arm. Z-coverage was varied by clipping the 3D bone models prior to registration. The radius position relative to the ulna was obtained from the segmentation image. Apparent relative displacement seen in the target images is caused by registration errors. Worst-case translations were 0.45, 0.08 and 1.1 mm for SNR-, Z-coverage- and motion-related errors respectively. Worst-case rotations were 0.41, 0.13 and 6.0 degrees. This study showed that quantification of the methodological error enables composition of accurate and precise DRUJ motion scanning protocols.


Subject(s)
Four-Dimensional Computed Tomography , Wrist Joint , Humans , Biomechanical Phenomena , Four-Dimensional Computed Tomography/methods , Motion , Phantoms, Imaging , Cadaver
6.
Biochem Biophys Res Commun ; 426(1): 54-8, 2012 Sep 14.
Article in English | MEDLINE | ID: mdl-22910417

ABSTRACT

Collagen is the main load-bearing component of the artery. The 3D arrangement of the collagen fibers is crucial to understand the mechanical behavior of such tissues. We compared collagen fiber alignment obtained by second harmonic generation (SHG) microscopy with the alignment obtained by diffusion tensor imaging (DTI) throughout the wall of a porcine carotid artery to check the feasibility of using DTI as a fast and non-destructive method instead of SHG. The middle part of the artery was cut into two segments: one for DTI and one for the SHG measurements. The tissue for SHG measurements was cut into 30µm tangential sections. After scanning all sections, they were registered together and the fiber orientation was quantified by an in-house algorithm. The tissue for DTI measurement was embedded in type VII agarose and scanned with an MRI-scanner. Fiber tractography was performed on the DTI images. Both methods showed a layered structure of the wall. The fibers were mainly oriented circumferentially in the outer adventitia and media. DTI revealed the predominant layers of the arterial wall. This study showed the feasibility of using DTI for evaluating the collagen orientation in native artery as a fast and non-destructive method.


Subject(s)
Carotid Arteries/ultrastructure , Collagen/chemistry , Diffusion Tensor Imaging , Animals , Mechanical Phenomena , Swine , Tissue Embedding
7.
Eur Radiol ; 22(12): 2806-13, 2012 Dec.
Article in English | MEDLINE | ID: mdl-22797954

ABSTRACT

OBJECTIVES: To prospectively explore the clinical application of diffusion tensor imaging (DTI) and fibre tractography in evaluating the pelvic floor. METHODS: Ten patients with pelvic organ prolapse, ten with pelvic floor symptoms and ten asymptomatic women were included. A two-dimensional (2D) spin-echo (SE) echo-planar imaging (EPI) sequence of the pelvic floor was acquired. Offline fibre tractography and morphological analysis of pelvic magnetic resonance imaging (MRI) were performed. Inter-rater agreement for quality assessment of fibre tracking results was evaluated using weighted kappa (κ). From agreed tracking results, eigen values (λ1, λ2, λ3), mean diffusivity (MD) and fractional anisotropy (FA) were calculated. MD and FA values were compared using ANOVA. Inter-rater reliability of DTI parameters was interpreted using the intra-class correlation coefficient (ICC). RESULTS: Substantial inter-rater agreement was found (κ = 0.71 [95% CI 0.63-0.78]). Four anatomical structures were reliably identified. Substantial inter-rater agreement was found for MD and FA (ICC 0.60-0.91). No significant differences between groups were observed for anal sphincter, perineal body and puboperineal muscle. A significant difference in FA was found for internal obturator muscle between the prolapse group and the asymptomatic group (0.27 ± 0.05 vs 0.22 ± 0.03; P = 0.015). CONCLUSION: DTI with fibre tractography permits identification of part of the clinically relevant pelvic structures. Overall, no significant differences in DTI parameters were found between groups. KEY POINTS: Diffusion tensor MRI offers new insights into female pelvic floor problems. DTI allows 3D visualisation and quantification of female pelvic floor anatomy. DTI parameters from pelvic floor structures can be reliably determined. No significant differences in DTI parameters between groups with/without prolapse.


Subject(s)
Diffusion Magnetic Resonance Imaging/methods , Muscle Fibers, Skeletal , Pelvic Floor/physiopathology , Pelvic Organ Prolapse/physiopathology , Adult , Analysis of Variance , Anisotropy , Cross-Sectional Studies , Echo-Planar Imaging , Female , Humans , Imaging, Three-Dimensional , Prospective Studies
8.
Magn Reson Med ; 66(2): 528-37, 2011 Aug.
Article in English | MEDLINE | ID: mdl-21360588

ABSTRACT

Pressure ulcers are localized areas of soft tissue breakdown due to mechanical loading. Susceptible individuals are subjected to pressure relief strategies to prevent long loading periods. Therefore, ischemia-reperfusion injury may play an important role in the etiology of pressure ulcers. To investigate the inter-relation between postischemic perfusion and changes in skeletal muscle integrity, the hindlimbs of Brown Norway rats were subjected to 4-h ischemia followed by 2-h reperfusion. Dynamic contrast-enhanced MRI was used to examine perfusion, and changes in skeletal muscle integrity were monitored with T2-weighted MRI. The dynamic contrast-enhanced MRI data showed a heterogeneous postischemic profile in the hindlimb, consisting of areas with increased contrast enhancement (14-76% of the hindlimb) and regions with no-reflow (5-77%). For T2, a gradual increase in the complete leg was observed during the 4-h ischemic period (from 34 to 41 msec). During the reperfusion phase, a heterogeneous distribution of T2 was observed. Areas with increased contrast enhancement were associated with a decrease in T2 (to 38 msec) toward preischemic levels, whereas no-reflow areas exhibited a further increase in T2 (to 42 msec). These results show that reperfusion after prolonged ischemia may not be complete, thereby continuing the ischemic condition and aggravating tissue damage.


Subject(s)
Heterocyclic Compounds , Magnetic Resonance Imaging/methods , Muscle, Skeletal/pathology , Muscular Diseases/pathology , Organometallic Compounds , Pressure Ulcer/pathology , Reperfusion Injury/pathology , Animals , Contrast Media , Female , Gadolinium , Rats , Reproducibility of Results , Sensitivity and Specificity
9.
Eur Radiol ; 21(6): 1243-9, 2011 Jun.
Article in English | MEDLINE | ID: mdl-21197534

ABSTRACT

OBJECTIVES: To prospectively determine the feasibility of diffusion tensor imaging (DTI) with fibre tractography as a tool for the three-dimensional (3D) visualisation of normal pelvic floor anatomy. METHODS: Five young female nulliparous subjects (mean age 28 ± 3 years) underwent DTI at 3.0T. Two-dimensional diffusion-weighted axial spin-echo echo-planar (SP-EPI) pulse sequence of the pelvic floor was performed, with additional T2-TSE multiplanar sequences for anatomical reference. Fibre tractography for visualisation of predefined pelvic floor and pelvic wall muscles was performed offline by two observers, applying a consensus method. Three eigenvalues (λ1, λ2, λ3), fractional anisotropy (FA) and mean diffusivity (MD) were calculated from the fibre trajectories. RESULTS: In all subjects fibre tractography resulted in a satisfactory anatomical representation of the pubovisceral muscle, perineal body, anal - and urethral sphincter complex and internal obturator muscle. Mean FA values ranged from 0.23 ± 0.02 to 0.30 ± 0.04, MD values from 1.30 ± 0.08 to 1.73 ± 0.12 × 10(-)³ mm²/s. Muscular structures in the superficial layer of the pelvic floor could not be satisfactorily identified. CONCLUSIONS: This study demonstrates the feasibility of visualising the complex three-dimensional pelvic floor architecture using 3T-DTI with fibre tractography. DTI of the deep female pelvic floor may provide new insights into pelvic floor disorders.


Subject(s)
Algorithms , Diffusion Tensor Imaging/methods , Image Interpretation, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Muscle Fibers, Skeletal/cytology , Pelvic Floor/anatomy & histology , Adult , Feasibility Studies , Female , Humans , Image Enhancement/methods , Reference Values , Reproducibility of Results , Sensitivity and Specificity
10.
Int J Comput Assist Radiol Surg ; 16(3): 505-513, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33475897

ABSTRACT

PURPOSE: In corrective osteotomy of the distal radius, patient-specific 3D printed surgical guides or optical navigation systems are often used to navigate the surgical saw. The purpose of this cadaver study is to present and evaluate a novel cast-based guiding system to transfer the virtually planned corrective osteotomy of the distal radius. METHODS: We developed a cast-based guiding system composed of a cast featuring two drilling slots as well as an external cutting guide that was used to orient the surgical saw for osteotomy in the preoperatively planned position. The device was tested on five cadaver specimens with different body fat percentages. A repositioning experiment was performed to assess the precision of replacing an arm in the cast. Accuracy and precision of drilling and cutting using the proposed cast-based guiding system were evaluated using the same five cadaver arms. CT imaging was used to quantify the positioning errors in 3D. RESULTS: For normal-weight cadavers, the resulting total translation and rotation repositioning errors were ± 2 mm and ± 2°. Across the five performed surgeries, the median accuracy and Inter Quartile Ranges (IQR) of pre-operatively planned drilling trajectories were 4.3° (IQR = 2.4°) and 3.1 mm (IQR = 4.9 mm). Median rotational and translational errors in transferring the pre-operatively planned osteotomy plane were and 3.9° (IQR = 4.5°) and 2.6 mm (IQR = 4.2 mm), respectively. CONCLUSION: For normal weight arm specimens, navigation of corrective osteotomy via a cast-based guide resulted in transfer errors comparable to those using invasive surgical guides. The promising positioning capabilities justify further investigating whether the method could ultimately be used in a clinical setting, which could especially be of interest when used with less invasive osteosynthesis material.


Subject(s)
Carpal Bones/diagnostic imaging , Osteotomy/methods , Plastic Surgery Procedures/methods , Printing, Three-Dimensional , Surgery, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Cadaver , Computer-Aided Design , Elasticity , Humans , Radius , Reproducibility of Results , Rotation
11.
Sci Rep ; 11(1): 19781, 2021 10 05.
Article in English | MEDLINE | ID: mdl-34611247

ABSTRACT

Diffusible iodine-based contrast-enhanced computed tomography (diceCT) is progressively used in clinical and morphological research to study developmental anatomy. Lugol's solution (Lugol) has gained interest as an effective contrast agent; however, usage is limited due to extensive soft-tissue shrinkage. The mechanism of Lugol-induced shrinkage and how to prevent it is largely unknown, hampering applications of Lugol in clinical or forensic cases where tissue shrinkage can lead to erroneous diagnostic conclusions. Shrinkage was suggested to be due to an osmotic imbalance between tissue and solution. Pilot experiments pointed to acidification of Lugol, but the relation of acidification and tissue shrinkage was not evaluated. In this study, we analyzed the relation between tissue shrinkage, osmolarity and acidification of the solution during staining. Changes in tissue volume were measured on 2D-segmented magnetic resonance and diceCT images using AMIRA software. Partial correlation and stepwise regression analysis showed that acidification of Lugol is the main cause of tissue shrinkage. To prevent acidification, we developed a buffered Lugol's solution (B-Lugol) and showed that stabilizing its pH almost completely prevented shrinkage without affecting staining. Changing from Lugol to B-Lugol is a major improvement for clinical and morphological research and only requires a minor adaptation of the staining protocol.


Subject(s)
Artifacts , Connective Tissue/anatomy & histology , Connective Tissue/diagnostic imaging , Contrast Media , Iodides , Staining and Labeling/methods , Animals , Fetus/diagnostic imaging , Humans , Hydrogen-Ion Concentration , Mice , Tomography, X-Ray Computed/methods , Tomography, X-Ray Computed/standards
12.
NMR Biomed ; 23(8): 939-51, 2010 Oct.
Article in English | MEDLINE | ID: mdl-20878972

ABSTRACT

Single fast spin echo scans covering limited time frames are mostly used for contrast-enhanced MRI of atherosclerotic plaque biomarkers. Knowledge on inter-scan variability of the normalized enhancement ratio of plaque (NER(plaque)) and relation between NER(plaque) and gadolinium content for inversion-recovery fast spin echo is limited. Study aims were: evaluation of (1) timing of MRI after intravenous injection of cannabinoid-2 receptor (CB2-R) (expressed by human and mouse plaque macrophages) targeted micelles; (2) inter-scan variability of inversion-recovery fast spin echo and fast spin echo; (3) relation between NER(plaque) and gadolinium content for inversion-recovery fast spin echo and fast spin echo. Inversion-recovery fast spin echo/fast spin echo imaging was performed before and every 15 min up to 48 h after injection of CB2-R targeted or control micelles using several groups of mice measured in an interleaved fashion. NER(plaque) (determined on inversion-recovery fast spin echo images) remained high (∼2) until 48 h after injection of CB2-R targeted micelles, whereas NER(plaque) decreased after 36 h in the control group. The inter-scan variability and relation between NER(plaque) and gadolinium (assessed with inductively coupled plasma- mass spectrometry) were compared between inversion-recovery fast spin echo and fast spin echo. Inter-scan variability was higher for inversion-recovery fast spin echo than for fast spin echo. Although gadolinium and NER(plaque) correlated well for both techniques, the NER of plaque was higher for inversion-recovery fast spin echo than for fast spin echo. In mice injected with CB2-R targeted micelles, NER(plaque) can be best evaluated at 36-48 h post-injection. Because NER(plaque) was higher for inversion-recovery fast spin echo than for fast spin echo, but with high inter-scan variability, repeated inversion-recovery fast spin echo imaging and averaging of the obtained NER(plaque) values is recommended.


Subject(s)
Gadolinium/metabolism , Image Enhancement/methods , Magnetic Resonance Imaging/methods , Micelles , Plaque, Atherosclerotic , Receptor, Cannabinoid, CB2/metabolism , Animals , Apolipoproteins E/genetics , Biomarkers/metabolism , Humans , Magnetic Resonance Imaging/instrumentation , Mice , Mice, Knockout , Nitric Oxide Synthase Type III/genetics , Plaque, Atherosclerotic/metabolism , Plaque, Atherosclerotic/pathology , Time Factors , Tissue Distribution
13.
AJNR Am J Neuroradiol ; 41(7): 1201-1208, 2020 07.
Article in English | MEDLINE | ID: mdl-32586964

ABSTRACT

BACKGROUND AND PURPOSE: Patients with intracranial aneurysms may benefit from 4D flow MR imaging because the derived wall shear stress is considered a useful marker for risk assessment and growth of aneurysms. However, long scan times limit the clinical implementation of 4D flow MR imaging. Therefore, this study aimed to investigate whether highly accelerated, high resolution, 4D flow MR imaging at 7T provides reliable quantitative blood flow values in intracranial arteries and aneurysms. MATERIALS AND METHODS: We used pseudospiral Cartesian undersampling with compressed sensing reconstruction to achieve high spatiotemporal resolution (0.5 mm isotropic, ∼30 ms) in a scan time of 10 minutes. We analyzed the repeatability of accelerated 4D flow scans and compared flow rates, stroke volume, and the pulsatility index with 2D flow and conventional 4D flow MR imaging in a flow phantom and 15 healthy subjects. Additionally, accelerated 4D flow MR imaging with high spatiotemporal resolution was acquired in 5 patients with aneurysms to derive wall shear stress. RESULTS: Flow-rate bias compared with 2D flow was lower for accelerated than for conventional 4D flow MR imaging (0.31 ± 0.13, P = .22, versus 0.79 ± 0.17 mL/s, P < .01). Pulsatility index bias gave similar results. Stroke volume bias showed no difference for accelerated as well as for conventional 4D flow compared to 2D flow MR imaging. Repeatability for accelerated 4D flow was similar to that of 2D flow MR imaging. Increased temporal resolution for wall shear stress measurements in 5 intracranial aneurysms did not show a consistent effect for the wall shear stress but did show an effect for the oscillatory shear index. CONCLUSIONS: Highly accelerated high spatiotemporal resolution 4D flow MR imaging at 7T in intracranial arteries and aneurysms provides repeatable and accurate quantitative flow values. Flow rate accuracy is significantly increased compared with conventional 4D flow scans.


Subject(s)
Intracranial Aneurysm/diagnostic imaging , Magnetic Resonance Imaging/methods , Neuroimaging/methods , Adult , Cerebrovascular Circulation/physiology , Female , Healthy Volunteers , Hemodynamics/physiology , Humans , Male , Middle Aged , Phantoms, Imaging
14.
J Mech Behav Biomed Mater ; 92: 50-57, 2019 04.
Article in English | MEDLINE | ID: mdl-30658240

ABSTRACT

Pressure-induced deep tissue injury is a form of pressure ulcer which is difficult to detect and diagnose at an early stage, before the wound has severely progressed and becomes visible at the skin surface. At the present time, no such detection technique is available. To test the hypothesis that muscle damage biomarkers can be indicative of the development of deep tissue injury after sustained mechanical loading, an indentation test was performed for 2 h on the tibialis anterior muscle of rats. Myoglobin and troponin were analysed in blood plasma and urine over a period of 5 days. The damage as detected by the biomarkers was compared to damage as observed with T2 MRI to validate the response. We found that myoglobin and troponin levels in blood increased due to the damage. Myoglobin was also increased in urine. The amount of damage observed with MRI immediately after loading had a strong correlation with the maximal biomarker levels: troponin in blood rs = 0.94; myoglobin in blood rs = 0.75; and myoglobin in urine rs = 0.57. This study suggests that muscle damage markers measured in blood and urine could serve as early diagnosis for pressure induced deep tissue injury.


Subject(s)
Myoglobin/metabolism , Pressure Ulcer/metabolism , Troponin/metabolism , Animals , Biomarkers/blood , Biomarkers/metabolism , Biomarkers/urine , Female , Magnetic Resonance Imaging , Myoglobin/blood , Pressure Ulcer/blood , Pressure Ulcer/diagnostic imaging , Pressure Ulcer/urine , Rats , Rats, Sprague-Dawley , Troponin/blood , Troponin/urine
15.
Med Biol Eng Comput ; 57(5): 1099-1107, 2019 May.
Article in English | MEDLINE | ID: mdl-30588576

ABSTRACT

Use of patient-specific fixation plates is promising in corrective osteotomy of the distal radius. So far, custom plates were mostly shaped to closely fit onto the bone surface and ensure accurate positioning of bone segments, however, without considering the biomechanical needs for bone healing. In this study, we investigated how custom plates can be optimized to stimulate callus formation under daily loading conditions. We calculated implant stress distributions, axial screw forces, and interfragmentary strains via finite element analysis (FEA) and compared these parameters for a corrective distal radius osteotomy model fixated by standard and custom plates. We then evaluated these parameters in a modified custom plate design with alternative screw configuration, plate size, and thickness on 5 radii models. Compared to initial design, in the modified custom plate, the maximum stress was reduced, especially under torsional load (- 31%). Under bending load, implants with 1.9-mm thickness induced an average strain (median = 2.14%, IQR = 0.2) in the recommended range (2-10%) to promote callus formation. Optimizing the plate shape, width, and thickness in order to keep the fixation stable while guaranteeing sufficient strain to enhance callus formation can be considered as a design criteria for future, less invasive, custom distal radius plates. Graphical abstract ᅟ.


Subject(s)
Bone Plates , Computer-Aided Design , Osteotomy/instrumentation , Radius/surgery , Biomechanical Phenomena , Bone Screws , Finite Element Analysis , Humans , Osteotomy/methods , Precision Medicine/methods , Radius/injuries , Radius Fractures
16.
Eur Radiol Exp ; 3(1): 7, 2019 Feb 06.
Article in English | MEDLINE | ID: mdl-30725241

ABSTRACT

BACKGROUND: To investigate the feasibility of compressed sensing and parallel imaging (CS-PI)-accelerated bowel motility magnetic resonance imaging (MRI) and to compare its image quality and diagnostic quality to conventional sensitivity encoding (SENSE) accelerated scans. METHODS: Bowel MRI was performed in six volunteers using a three-dimensional balanced fast field-echo sequence. Static scans were performed after the administration of a spasmolytic agent to prevent bowel motion artefacts. Fully sampled reference scans and multiple prospectively 3× to 7× undersampled CS-PI and SENSE scans were acquired. Additionally, fully sampled CS-PI and SENSE scans were retrospectively undersampled and reconstructed. Dynamic scans were performed using 5× to 7× accelerated scans in the presence of bowel motion. Retrospectively, undersampled scans were compared to fully sampled scans using structural similarity indices. All reconstructions were visually assessed for image quality and diagnostic quality by two radiologists. RESULTS: For static imaging, the performance of CS-PI was lower than that of fully sampled and SENSE scans: the diagnostic quality was assessed as adequate or good for 100% of fully sampled scans, 95% of SENSE, but only for 55% of CS-PI scans. For dynamic imaging, CS-PI image quality was scored similar to SENSE at high acceleration. Diagnostic quality of all scans was scored as adequate or good; 55% of CS-PI and 83% of SENSE scans were scored as good. CONCLUSION: Compared to SENSE, current implementation of CS-PI performed less or equally good in terms of image quality and diagnostic quality. CS-PI did not show advantages over SENSE for three-dimensional bowel motility imaging.

17.
Int J Comput Assist Radiol Surg ; 14(5): 829-840, 2019 May.
Article in English | MEDLINE | ID: mdl-30535827

ABSTRACT

PURPOSE: 3D-printed patient-specific instruments (PSIs), such as surgical guides and implants, show great promise for accurate navigation in surgical correction of post-traumatic deformities of the distal radius. However, existing costs of computer-aided design and manufacturing process prevent everyday surgical use. In this paper, we propose an innovative semiautomatic methodology to streamline the PSIs design. METHODS: The new method was implemented as an extension of our existing 3D planning software. It facilitates the design of a regular and smooth implant and a companion guide starting from a user-selected surface on the affected bone. We evaluated the software by designing PSIs starting from preoperative virtual 3D plans of five patients previously treated at our institute for corrective osteotomy. We repeated the design for the same cases also with commercially available software, with and without dedicated customization. We measured design time and tracked user activity during the design process of implants, guides and subsequent modifications. RESULTS: All the designed shapes were considered valid. Median design times ([Formula: see text]) were reduced for implants (([Formula: see text]) = 2.2 min) and guides (([Formula: see text]) = 1.0 min) compared to the standard (([Formula: see text]) = 13 min and ([Formula: see text]) = 8 min) and the partially customized (([Formula: see text]) = 6.5 min and ([Formula: see text]) = 6.0 min) commercially available alternatives. Mouse and keyboard activities were reduced (median count of strokes and clicks during implant design (([Formula: see text]) = 53, and guide design (([Formula: see text]) = 27) compared to using standard software (([Formula: see text]) = 559 and ([Formula: see text]) = 380) and customized commercial software (([Formula: see text]) = 217 and ([Formula: see text]) = 180). CONCLUSION: Our software solution efficiently streamlines the design of PSIs for distal radius malunion. It represents a first step in making 3D-printed PSIs technology more accessible.


Subject(s)
Osteotomy/instrumentation , Printing, Three-Dimensional , Radius Fractures/surgery , Radius/surgery , Surgery, Computer-Assisted/methods , Computer-Aided Design , Humans , Radius/diagnostic imaging , Radius/injuries , Radius Fractures/diagnosis
18.
Comput Biol Med ; 115: 103516, 2019 12.
Article in English | MEDLINE | ID: mdl-31707199

ABSTRACT

Treatment selection is becoming increasingly more important in acute ischemic stroke patient care. Clinical variables and radiological image biomarkers (old age, pre-stroke mRS, NIHSS, occlusion location, ASPECTS, among others) have an important role in treatment selection and prognosis. Radiological biomarkers require expert annotation and are subject to inter-observer variability. Recently, Deep Learning has been introduced to reproduce these radiological image biomarkers. Instead of reproducing these biomarkers, in this work, we investigated Deep Learning techniques for building models to directly predict good reperfusion after endovascular treatment (EVT) and good functional outcome using CT angiography images. These models do not require image annotation and are fast to compute. We compare the Deep Learning models to Machine Learning models using traditional radiological image biomarkers. We explored Residual Neural Network (ResNet) architectures, adapted them with Structured Receptive Fields (RFNN) and auto-encoders (AE) for network weight initialization. We further included model visualization techniques to provide insight into the network's decision-making process. We applied the methods on the MR CLEAN Registry dataset with 1301 patients. The Deep Learning models outperformed the models using traditional radiological image biomarkers in three out of four cross-validation folds for functional outcome (average AUC of 0.71) and for all folds for reperfusion (average AUC of 0.65). Model visualization showed that the arteries were relevant features for functional outcome prediction. The best results were obtained for the ResNet models with RFNN. Auto-encoder initialization often improved the results. We concluded that, in our dataset, automated image analysis with Deep Learning methods outperforms radiological image biomarkers for stroke outcome prediction and has the potential to improve treatment selection.


Subject(s)
Brain Ischemia , Cerebral Angiography , Computed Tomography Angiography , Endovascular Procedures/adverse effects , Neural Networks, Computer , Postoperative Complications/diagnostic imaging , Registries , Stroke/diagnostic imaging , Aged , Aged, 80 and over , Brain Ischemia/diagnostic imaging , Brain Ischemia/etiology , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Stroke/etiology
19.
J Biomech ; 41(16): 3399-404, 2008 Dec 05.
Article in English | MEDLINE | ID: mdl-19010470

ABSTRACT

Prolonged mechanical loading of soft tissues adjacent to bony prominences can lead to degeneration of muscle tissue, resulting in a condition termed pressure-related deep tissue injury. This type of deep pressure ulcers can develop into a severe wound, associated with problematic healing and a variable prognosis. Limited knowledge of the underlying damage pathways impedes effective preventive strategies and early detection. Traditionally, pressure-induced ischaemia has been thought to be the main aetiological factor for initiating damage. Recent research, however, proposes tissue deformation per se as another candidate for initiating pressure-induced deep tissue injury. In this study, different strain parameters were evaluated on their suitability as a generic predictive indicator for deep tissue injury. With a combined animal-experimental numerical approach, we show that there is a reproducible monotonic increase in damage with increasing maximum shear strain once a strain threshold has been exceeded. This relationship between maximum shear strain and damage seems to reflect an intrinsic muscle property, as it applied across a considerable number of the experiments. This finding confirms that tissue deformation per se is important in the aetiology of deep tissue injury. Using dedicated finite element modeling, a considerable reduction in the inherent biological variation was obtained, leading to the proposal that muscle deformation can prove a generic predictive indicator of damage.


Subject(s)
Disease Models, Animal , Models, Biological , Physical Stimulation/adverse effects , Pressure Ulcer/etiology , Pressure Ulcer/physiopathology , Animals , Compressive Strength , Computer Simulation , Elastic Modulus , Female , Pressure , Rats , Stress, Mechanical
20.
Eur Spine J ; 17(8): 1006-11, 2008 Aug.
Article in English | MEDLINE | ID: mdl-18512084

ABSTRACT

Nonunion is a major complication of spinal interbody fusion. Currently X-ray and computed tomography (CT) are used for evaluating the spinal fusion process. However, both imaging modalities have limitations in judgment of the early stages of this fusion process, as they only visualize mineralized bone. Magnetic resonance imaging (MRI) could be of great value as it is able to discriminate between different types of tissue. A feasibility study was performed in nine animals from a goat spinal fusion study, to evaluate the detection capacity of different tissues with micro-MRI. In this study bioresorbable polylactic acid cages were used. Six- and 12-months follow-up specimens were scanned in a 6.3 T micro-MRI scanner. After scanning, the specimens were processed for histology. Different types of tissue as well as the degradable cage material were identified in the fusion zone and designated as regions of interest (ROIs). Subsequently, the location of these ROIs was determined on the corresponding micro-MRI image, and average signal intensities of every individual ROI were measured. An excellent match was seen between the histological sections and micro-MRI images. The micro-MRI images showed quantifiable differences in signal intensity between bone with adipose marrow, bone with hematopoietic marrow, fibrocartilage, fibrous tissue, and degradable implant material. In time the signal intensity of bone with adipose marrow, bone with hematopoietic red marrow, and of fibrous tissue remained relatively constant. On the other hand, the signal intensity of the degradable implant material and the fibrocartilage changed significantly in time, indicating change of structure and composition. In conclusion, in our model using bioresorbable cages the MRI provides us with detailed information about the early fusion process and may therefore, allow early diagnosis of non-union.


Subject(s)
Absorbable Implants , Bone Marrow/pathology , Bone and Bones/pathology , Cartilage/pathology , Magnetic Resonance Imaging , Spinal Fusion , Animals , Bone Marrow/surgery , Bone and Bones/surgery , Cartilage/surgery , Goats