Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Ann Biomed Eng ; 52(4): 888-897, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38157105

ABSTRACT

Coexisting hypertension and aortic stenosis are common. Some studies showed that elevated blood pressures may be associated with progression of calcific aortic valve disease (CAVD) while others showed no correlation. Flow dynamics in the sinuses of Valsalva are considered key factors in the progression of CAVD. While the relationship between hemodynamics and CAVD is not yet fully understood, it has been demonstrated that they are tightly correlated. This study aims to investigate the effect of changing systolic and diastolic blood pressures (SBP and DBP, respectively) on sinus hemodynamics in relation to potential initiation or progression of CAVD after aortic valve replacement (AVR). Evolut R, SAPIEN 3 and Magna valves were deployed in an aortic root under pulsatile conditions. Using particle image velocimetry, the hemodynamics in the sinus were assessed. The velocity, vorticity, circulation ( Γ ) and shear stress were calculated. This study shows that under elevated SBP and DBP, velocity, vorticity, and shear stress nearby the leaflets increased. Additionally, larger fluctuations of Γ and area under the curve throughout the cardiac cycle were observed. Elevated blood pressures are associated with higher velocity, vorticity, and shear stress near the leaflets which may initiate or accelerate pro-calcific changes in the prosthetic leaflets leading to bioprosthetic valve degeneration.


Subject(s)
Aortic Valve Disease , Aortic Valve Stenosis , Aortic Valve/pathology , Calcinosis , Humans , Blood Pressure , Aortic Valve/surgery , Hemodynamics
2.
J Am Heart Assoc ; 13(4): e032963, 2024 Feb 20.
Article in English | MEDLINE | ID: mdl-38348804

ABSTRACT

BACKGROUND: Acute ischemic stroke complicates 2% to 3% of transcatheter aortic valve replacements (TAVRs). This study aimed to identify the aortic anatomic correlates in patients after TAVR stroke. METHODS AND RESULTS: This is a single-center, retrospective study of patients who underwent TAVR at the Mayo Clinic between 2012 and 2022. The aortic arch morphology was determined via a manual review of the pre-TAVR computed tomography images. An "a priori" approach was used to select the covariates for the following: (1) the logistic regression model assessing the association between a bovine arch and periprocedural stroke (defined as stroke within 7 days after TAVR); and (2) the Cox proportional hazards regression model assessing the association between a bovine arch and long-term stroke after TAVR. A total of 2775 patients were included (59.6% men; 97.8% White race; mean±SD age, 79.3±8.4 years), of whom 495 (17.8%) had a bovine arch morphology. Fifty-seven patients (1.7%) experienced a periprocedural stroke. The incidence of acute stroke was significantly higher among patients with a bovine arch compared with those with a nonbovine arch (3.6% versus 1.7%; P=0.01). After adjustment, a bovine arch was independently associated with increased periprocedural strokes (adjusted odds ratio, 2.16 [95% CI, 1.22-3.83]). At a median follow-up of 2.7 years, the overall incidence of post-TAVR stroke was 6.0% and was significantly higher in patients with a bovine arch even after adjusting for potential confounders (10.5% versus 5.0%; adjusted hazard ratio, 2.11 [95% CI, 1.51-2.93]; P<0.001). CONCLUSIONS: A bovine arch anatomy is associated with a significantly higher risk of periprocedural and long-term stroke after TAVR.


Subject(s)
Aortic Valve Stenosis , Ischemic Stroke , Stroke , Transcatheter Aortic Valve Replacement , Male , Humans , Aged , Aged, 80 and over , Female , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/epidemiology , Aortic Valve Stenosis/surgery , Retrospective Studies , Ischemic Stroke/surgery , Treatment Outcome , Risk Factors , Stroke/etiology
3.
Heart Rhythm ; 21(7): 1024-1031, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38365125

ABSTRACT

BACKGROUND: The hemodynamic effects of transcatheter left atrial appendage occlusion (LAAO) remain unclear. OBJECTIVE: We sought to assess the effect of LAAO on invasive hemodynamics and their correlation with clinical outcomes. METHODS: We recorded mean left atrial pressure (mLAP) before and after device deployment. We assessed the prevalence and predictors of mLAP increase after deployment, the association between significant mLAP increase after deployment and 45-day peridevice leak (PDL), and the association between mLAP increase and heart failure (HF) hospitalization. A significant mLAP increase was defined as one equal to or greater than the mean percentage increase in mLAP after deployment (≥28%). RESULTS: We included 302 patients (36.4% female; mean age, 75.8 ± 9.5 years). After deployment, mLAP increased in 48% of patients, 38% of whom experienced significant mLAP increase. Independent predictors of mLAP increase were baseline mLAP ≤14 mm Hg, nonparoxysmal atrial fibrillation, and age per 5 years (odds ratios: 3.66 [95% CI, 2.21-6.05], 1.81 [95% CI, 1.08-3.02], and 0.85 [95% CI, 0.73-0.99], respectively). Significant mLAP increase was an independent predictor of 45-day PDL (odds ratio, 2.55; 95% CI, 1.04-6.26). There was no association between mLAP increase and HF hospitalization. CONCLUSION: After deployment, mLAP acutely rises in 48% of patients, although this is not associated with increased HF hospitalizations. PDL is more likely to develop at 45 days in patients with significant increase in mLAP after deployment, although most leaks were small (<5 mm). These findings suggest that mLAP increase after deployment is not associated with major safety concerns. Additional studies are warranted to explore the long-term hemodynamic effects of LAAO.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Atrial Pressure , Cardiac Catheterization , Hemodynamics , Humans , Female , Atrial Appendage/physiopathology , Atrial Appendage/surgery , Male , Aged , Atrial Fibrillation/physiopathology , Atrial Fibrillation/surgery , Atrial Fibrillation/therapy , Cardiac Catheterization/methods , Atrial Pressure/physiology , Hemodynamics/physiology , Septal Occluder Device , Retrospective Studies , Atrial Function, Left/physiology , Follow-Up Studies , Echocardiography, Transesophageal
4.
Clin Med (Lond) ; 23(5): 495-502, 2023 09.
Article in English | MEDLINE | ID: mdl-37775180

ABSTRACT

The development of safe and effective vaccines against severe acute respiratory syndrome-coronavirus 2 (SARS-CoV-2) was a major turning point in the fight against the Coronavirus 2019 (COVID-19) pandemic. However, pharmacovigilance has revealed a small but significant incidence of cardiac inflammation manifesting clinically as myocarditis or pericarditis, particularly in younger vaccine recipients. The incidence is the highest among men under age 40 within a week of receiving the second dose of the mRNA vaccine. In this review, we summarise the evidence for, and guidelines in relation to, SARS-CoV2 vaccine-related myocarditis.


Subject(s)
COVID-19 , Myocarditis , Pericarditis , Male , Humans , Adult , COVID-19 Vaccines/adverse effects , Myocarditis/etiology , RNA, Viral , COVID-19/prevention & control , SARS-CoV-2 , Vaccination
5.
Expert Rev Cardiovasc Ther ; 21(1): 57-65, 2023 01.
Article in English | MEDLINE | ID: mdl-36543329

ABSTRACT

INTRODUCTION: Conventional aortic root and valve-sparing root replacement surgery are two current surgical treatments for aortic dilatation syndromes. This review article aims to review the current literature surrounding these two established techniques. AREAS COVERED: This review article will address the current indications for valve-sparing root replacement surgery, technical considerations in surgical planning and a comparison of clinical outcomes between these two surgical techniques. EXPERT OPINION: Valve-sparing root replacement surgery is a safe and established treatment for aortic syndromes. Valve-sparing surgery procedure avoids the inherent risk of prosthetic valve dysfunction and prosthesis infection by preserving the native aortic valve compared to conventional aortic root surgery. This has been demonstrated in various observational studies and should be considered in clinically and anatomically appropriate patients. Other technical considerations, such as reimplantation versus remodeling technique and aortic cusp repair in select patients, may impact in short-term procedural and long-term clinical success with valve-sparing surgery.


Subject(s)
Aortic Diseases , Aortic Valve Insufficiency , Heart Valve Prosthesis Implantation , Humans , Syndrome , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Aorta, Thoracic/surgery , Dilatation/adverse effects , Aortic Valve/surgery , Aortic Diseases/surgery , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Treatment Outcome , Aortic Valve Insufficiency/surgery , Retrospective Studies
6.
Angiology ; 71(8): 677-688, 2020 09.
Article in English | MEDLINE | ID: mdl-32567327

ABSTRACT

Vascular calcification is a highly prevalent pathophenotype that is associated with aging, atherosclerotic cardiovascular disease, diabetes mellitus, and chronic kidney disease. When present, it portends a worse clinical outcome and predicts major adverse cardiovascular events. Heavily calcified coronary and peripheral artery lesions are difficult to dilate appropriately with conventional balloons during percutaneous intervention, and the use of several adjunctive strategies of plaque modification has been suggested. Intravascular lithotripsy (IVL) offers a novel option for lesion preparation of severely calcified plaques in coronary and peripheral vessels. It is unique among all technologies in its ability to modify calcium circumferentially and transmurally, thus modifying transmural conduit compliance. In this article, we summarize the currently available evidence on this technology, and we highlight its best clinical application through appropriate patient and lesion selection, with the main objective of optimizing stent delivery and implantation, and subsequent improved short- and long-term outcomes. We believe that the IVL balloon will transform the market, as it is easy to use, with predictable results. However, cost-effectiveness of such advanced technology will need to be considered.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Artery Disease/therapy , Lithotripsy , Vascular Calcification/therapy , Angioplasty, Balloon, Coronary/adverse effects , Angioplasty, Balloon, Coronary/instrumentation , Cardiac Catheters , Coronary Artery Disease/diagnostic imaging , Humans , Lithotripsy/adverse effects , Lithotripsy/instrumentation , Risk Factors , Severity of Illness Index , Stents , Treatment Outcome , Vascular Calcification/diagnostic imaging
7.
iScience ; 23(10): 101552, 2020 Oct 23.
Article in English | MEDLINE | ID: mdl-33083721

ABSTRACT

Trigeminal neuralgia (TN) is a common, debilitating neuropathic face pain syndrome often resistant to therapy. The familial clustering of TN cases suggests that genetic factors play a role in disease pathogenesis. However, no unbiased, large-scale genomic study of TN has been performed to date. Analysis of 290 whole exome-sequenced TN probands, including 20 multiplex kindreds and 70 parent-offspring trios, revealed enrichment of rare, damaging variants in GABA receptor-binding genes in cases. Mice engineered with a TN-associated de novo mutation (p.Cys188Trp) in the GABAA receptor Cl- channel γ-1 subunit (GABRG1) exhibited trigeminal mechanical allodynia and face pain behavior. Other TN probands harbored rare damaging variants in Na+ and Ca+ channels, including a significant variant burden in the α-1H subunit of the voltage-gated Ca2+ channel Cav3.2 (CACNA1H). These results provide exome-level insight into TN and implicate genetically encoded impairment of GABA signaling and neuronal ion transport in TN pathogenesis.

SELECTION OF CITATIONS
SEARCH DETAIL