Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 365
Filter
1.
Eur Heart J ; 45(11): 895-911, 2024 Mar 14.
Article in English | MEDLINE | ID: mdl-38441886

ABSTRACT

Atrial secondary tricuspid regurgitation (A-STR) is a distinct phenotype of secondary tricuspid regurgitation with predominant dilation of the right atrium and normal right and left ventricular function. Atrial secondary tricuspid regurgitation occurs most commonly in elderly women with atrial fibrillation and in heart failure with preserved ejection fraction in sinus rhythm. In A-STR, the main mechanism of leaflet malcoaptation is related to the presence of a significant dilation of the tricuspid annulus secondary to right atrial enlargement. In addition, there is an insufficient adaptive growth of tricuspid valve leaflets that become unable to cover the enlarged annular area. As opposed to the ventricular phenotype, in A-STR, the tricuspid valve leaflet tethering is typically trivial. The A-STR phenotype accounts for 10%-15% of clinically relevant tricuspid regurgitation and has better outcomes compared with the more prevalent ventricular phenotype. Recent data suggest that patients with A-STR may benefit from more aggressive rhythm control and timely valve interventions. However, little is mentioned in current guidelines on how to identify, evaluate, and manage these patients due to the lack of consistent evidence and variable definitions of this entity in recent investigations. This interdisciplinary expert opinion document focusing on A-STR is intended to help physicians understand this complex and rapidly evolving topic by reviewing its distinct pathophysiology, diagnosis, and multi-modality imaging characteristics. It first defines A-STR by proposing specific quantitative criteria for defining the atrial phenotype and for discriminating it from the ventricular phenotype, in order to facilitate standardization and consistency in research.


Subject(s)
Atrial Fibrillation , Heart Failure , Tricuspid Valve Insufficiency , Humans , Female , Aged , Tricuspid Valve Insufficiency/etiology , Tricuspid Valve Insufficiency/complications , Heart Atria/diagnostic imaging , Tricuspid Valve/diagnostic imaging , Atrial Fibrillation/diagnosis , Atrial Fibrillation/etiology , Atrial Fibrillation/therapy
2.
Eur Heart J ; 45(8): 586-597, 2024 Feb 21.
Article in English | MEDLINE | ID: mdl-37624856

ABSTRACT

BACKGROUND AND AIMS: Benefit of tricuspid regurgitation (TR) correction and timing of intervention are unclear. This study aimed to compare survival rates after surgical or transcatheter intervention to conservative management according to a TR clinical stage as assessed using the TRI-SCORE. METHODS: A total of 2,413 patients with severe isolated functional TR were enrolled in TRIGISTRY (1217 conservatively managed, 551 isolated tricuspid valve surgery, and 645 transcatheter valve repair). The primary endpoint was survival at 2 years. RESULTS: The TRI-SCORE was low (≤3) in 32%, intermediate (4-5) in 33%, and high (≥6) in 35%. A successful correction was achieved in 97% and 65% of patients in the surgical and transcatheter groups, respectively. Survival rates decreased with the TRI-SCORE in the three treatment groups (all P < .0001). In the low TRI-SCORE category, survival rates were higher in the surgical and transcatheter groups than in the conservative management group (93%, 87%, and 79%, respectively, P = .0002). In the intermediate category, no significant difference between groups was observed overall (80%, 71%, and 71%, respectively, P = .13) but benefit of the intervention became significant when the analysis was restricted to patients with successful correction (80%, 81%, and 71%, respectively, P = .009). In the high TRI-SCORE category, survival was not different to conservative management in the surgical and successful repair group (61% and 68% vs 58%, P = .26 and P = .18 respectively). CONCLUSIONS: Survival progressively decreased with the TRI-SCORE irrespective of treatment modality. Compared to conservative management, an early and successful surgical or transcatheter intervention improved 2-year survival in patients at low and, to a lower extent, intermediate TRI-SCORE, while no benefit was observed in the high TRI-SCORE category.


Subject(s)
Cardiac Surgical Procedures , Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Humans , Treatment Outcome , Cardiac Catheterization
3.
Catheter Cardiovasc Interv ; 103(4): 560-564, 2024 03.
Article in English | MEDLINE | ID: mdl-38297982

ABSTRACT

We present three cases of acute coronary obstruction postsurgical repair of type A aortic dissection, which were successfully treated with percutaneous coronary intervention. We describe a step-by-step approach to performing percutaneous coronary intervention in selective cases of coronary obstruction related to type A aortic dissection.


Subject(s)
Aortic Dissection , Coronary Occlusion , Percutaneous Coronary Intervention , Humans , Coronary Vessels , Treatment Outcome , Aortic Dissection/diagnostic imaging , Aortic Dissection/surgery , Percutaneous Coronary Intervention/adverse effects , Stents
4.
Catheter Cardiovasc Interv ; 103(7): 1138-1144, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38695165

ABSTRACT

Following the introduction in the latest European and American guidelines, transcatheter edge-to-edge repair has become a valid alternative to surgery for ineligible patients. Among the available technologies, MitraClip (Abbott) was the first to be introduced for the percutaneous treatment of mitral regurgitation with the edge-to-edge technique. Although its safety and effectiveness has been widely demonstrated, the optimal procedural results are highly dependent from operators' experience. In this manuscript, we provide a full guide of advanced steering maneuvers of MitraClip in different scenarios of transseptal puncture.


Subject(s)
Cardiac Catheterization , Cardiac Catheters , Mitral Valve Insufficiency , Mitral Valve , Punctures , Humans , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Cardiac Catheterization/methods , Equipment Design , Heart Septum/surgery , Heart Septum/diagnostic imaging , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/physiopathology , Treatment Outcome
5.
Article in English | MEDLINE | ID: mdl-38773853

ABSTRACT

Transfemoral transcatheter aortic valve replacement is the preferred primary access route whenever possible. Despite advancements in expertise and delivery system profiles, complications associated with the primary femoral access still significantly affect procedural morbidity and outcomes. The current standard for accurate main access planning involves proper preprocedural evaluation guided by computed tomography. Several baseline clinical and anatomical features serve as predictors for the risk of vascular injury occurring during or after transcatheter aortic valve replacement. In this paper, we aimed at reviewing the most up-to-date knowledge of the topic for a safe transfemoral access approach according to a paradigm we have called "PIGTAIL."

6.
Eur Heart J ; 44(43): 4508-4532, 2023 11 14.
Article in English | MEDLINE | ID: mdl-37793121

ABSTRACT

Interest in the pathophysiology, etiology, management, and outcomes of patients with tricuspid regurgitation (TR) has grown in the wake of multiple natural history studies showing progressively worse outcomes associated with increasing TR severity, even after adjusting for multiple comorbidities. Historically, isolated tricuspid valve surgery has been associated with high in-hospital mortality rates, leading to the development of transcatheter treatment options. The aim of this first Tricuspid Valve Academic Research Consortium document is to standardize definitions of disease etiology and severity, as well as endpoints for trials that aim to address the gaps in our knowledge related to identification and management of patients with TR. Standardizing endpoints for trials should provide consistency and enable meaningful comparisons between clinical trials. A second Tricuspid Valve Academic Research Consortium document will focus on further defining trial endpoints and will discuss trial design options.


Subject(s)
Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Humans , Tricuspid Valve Insufficiency/diagnosis , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve Insufficiency/etiology , Tricuspid Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects , Cardiac Catheterization/adverse effects , Treatment Outcome , Severity of Illness Index
7.
Eur Heart J ; 44(10): 822-832, 2023 03 07.
Article in English | MEDLINE | ID: mdl-36445158

ABSTRACT

AIMS: The impact of sexuality in patients with significant tricuspid regurgitation (TR) undergoing transcatheter tricuspid valve intervention (TTVI) is unknown. The aim of this study was to investigate sex-specific outcomes in patients with significant TR treated with TTVI vs. medical therapy alone. METHODS AND RESULTS: The Transcatheter Tricuspid Valve Therapies (TriValve) registry collected data on patients with significant TR from 24 centres who underwent TTVI from 2016 to 2021. A control cohort was formed by medically managed patients with ≥severe isolated TR diagnosed in 2015-18. The primary endpoint was freedom from all-cause mortality. Secondary endpoints were heart failure (HF) hospitalization, New York Heart Association (NYHA) functional status, and TR severity. One-year outcomes were assessed for the TriValve cohort and compared with the control cohort with the inverse probability of treatment weighting (IPTW). A total of 556 and 2072 patients were included from the TriValve and control groups, respectively. After TTVI, there was no difference between women and men in 1-year freedom from all-cause mortality 80.9% vs. 77.9%, P = 0.56, nor in HF hospitalization (P = 0.36), NYHA Functional Classes III and IV (P = 0.17), and TR severity >2+ at last follow-up (P = 0.42). Multivariable Cox-regression weighted by IPTW showed improved 1-year survival after TTVI compared with medical therapy alone in both women (adjusted hazard ratio 0.45, 95% confidence interval 0.23-0.83, P = 0.01) and men (adjusted hazard ratio 0.42, 95% confidence interval 0.18-0.89, P = 0.03). CONCLUSION: After TTVI in high-risk patients, there were no sex-related differences in terms of survival, HF hospitalization, functional status, and TR reduction up to 1 year. The IPTW analysis shows a survival benefit of TTVI over medical therapy alone in both women and men.


Subject(s)
Heart Failure , Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Male , Humans , Female , Tricuspid Valve/surgery , Heart Valve Prosthesis Implantation/methods , Treatment Outcome , Registries , Heart Failure/complications
8.
Catheter Cardiovasc Interv ; 102(2): 318-327, 2023 08.
Article in English | MEDLINE | ID: mdl-37354444

ABSTRACT

BACKGROUND: Transcatheter mitral valve implantation (TMVI) is a novel therapeutic option for treating symptomatic mitral valve disease. Evaluating patient anatomical suitability is a critical step in the TMVI screening process, but currently requires specialized software and computerized device models. AIMS: This analysis sought to assess the effectiveness of simple and standardized multislice computed tomography (MSCT) anatomic measurements for their ability to discriminate between patients who passed anatomical screening for Tendyne™ TMVI. METHODS: Subjects screened for the Tendyne Expanded Clinical Study from January 2016 through September 2019 were included. Core laboratory screening measurements included mitral annular (MA) dimensions at end-systole and end-diastole, simulated device implantation, and neo-left ventricular outflow tract (LVOT) area. Additionally, nine standard measurements of patient anatomy were assessed for their predictive value of patients passing the anatomic screening process. RESULTS: Out of 496 subjects screened for eligibility, 257 subjects met clinical eligibility criteria with MA dimensions within the manufacturer's suggested range: 153 (59.5%) underwent TMVI while 104 (40.5%) were excluded from the study for other anatomic reasons (76% due to risk of LVOT obstruction). CT-derived left ventricular end-systole diameter (LVESD) had the highest discriminatory power for predicting TMVI anatomical suitability (area under the curve of 0.908, p < 0.0001). The mitral inter-commissural (IC) dimension was best predictive of annular dimensions being within range, with dimensions <30 or >50 mm resulting in a negative predictive value of 94.4%. CONCLUSIONS: MSCT-derived mitral IC dimension and LVESD easily performed measures that are effective predictors of anatomical suitability or screen failure for this tether-based TMVI device.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Insufficiency , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Cardiac Catheterization , Treatment Outcome
9.
Catheter Cardiovasc Interv ; 102(5): 931-943, 2023 11.
Article in English | MEDLINE | ID: mdl-37668097

ABSTRACT

BACKGROUND: Evidence of clinical impact of PPM after TAVI is conflicting and might vary according to the type of valve implanted. AIMS: To assess the clinical impact of prosthesis-patient mismatch (PPM) after transcatheter aortic valve implantation (TAVI) with balloon-expandable (BEV) and self-expandable valves (SEV) in patients with small annuli. METHODS: TAVI-SMALL 2 enrolled 628 patients in an international retrospective registry, which included patients with severe aortic stenosis and small annuli (annular perimeter <72 mm or area <400 mm2 ) treated with transfemoral TAVI at 16 high-volume centers between 2011 and 2020. Analyses were performed comparing patients with less than moderate (n = 452), moderate (n = 138), and severe PPM (n = 38). Primary endpoint was incidence of all-cause mortality. Predictors of all-cause mortality and PPM were investigated. RESULTS: At a median follow-up of 380 days (interquartile range: 210-709 days), patients with severe PPM, but not moderate PPM, had an increased risk of all-cause mortality when compared with less than moderate PPM (log-rank p = 0.046). Severe PPM predicted all-cause mortality in patients with BEV (hazard ratio [HR]: 5.20, 95% confidence interval [CI]: 1.27-21.2) and intra-annular valves (IAVs, HR: 4.23, 95% CI: 1.28-14.02), and it did so with borderline significance in the overall population (HR: 2.89, 95% CI: 0.95-8.79). Supra-annular valve (SAV) implantation was the only predictor of severe PPM (odds ratio: 0.33, 95% CI: 0.13-0.83). CONCLUSIONS: Patients with small aortic annuli and severe PPM after TAVI have an increased risk of all-cause mortality at early term follow-up, especially after IAV or BEV implantation. TAVI with SAV protected from severe PPM.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/etiology , Retrospective Studies , Prosthesis Design , Treatment Outcome , Transcatheter Aortic Valve Replacement/adverse effects
10.
Eur Heart J ; 43(17): 1626-1635, 2022 05 01.
Article in English | MEDLINE | ID: mdl-35090000

ABSTRACT

BACKGROUND: Randomized clinical trials demonstrated transcatheter edge-to-edge repair (TEER) efficacy in improving outcome vs. medical management for functional mitral regurgitation, but limited randomized data are available for the treatment of degenerative mitral regurgitation (DMR). We aimed to compare the outcome of older patients treated with TEER vs. unoperated DMR. METHODS AND RESULTS: Registries including consecutive patients ≥65 years with symptomatic severe DMR treated with TEER (MitraSwiss and Minneapolis Heart Institute registries) or unoperated (MIDA registry) were analysed. Survival was compared overall and after matching for age, sex, EuroSCORE II, and ejection fraction. The study included 1187 patients (872 treated with TEER and 315 unoperated). During 24 ± 17 months of follow-up, 430 patients died, 18 ± 1% at 1 year and 50 ± 2% at 4 years. Patients undergoing TEER had similar age (82 ± 6 vs. 82 ± 7 years) and sex to unoperated patients, but higher surgical risk/comorbidity (EuroSCORE II 3.98 ± 4.28% vs. 2.77 ± 2.46%), more symptoms, and atrial fibrillation (P < 0.0001). Transcatheter edge-to-edge repair was associated with lower mortality accounting for age, sex, EuroSCORE II, New York Heart Association class, atrial fibrillation, and ejection fraction [hazard ratio (HR): 0.47, 95% confidence interval (CI): 0.37-0.58; P < 0.0001]. After propensity matching (247 pairs of patients), TEER consistently showed better survival compared with unoperated patients (49 ± 6% vs. 37 ± 3% at 4 years, P < 0.0001) even in comprehensive multivariable analysis (HR: 0.60, 95% CI: 0.40-0.91; P = 0.03). Procedural failure was infrequent but post-procedural mitral regurgitation, remaining moderate-to-severe in 66 (7.6%) patients, was associated with excess mortality vs. trivial residual regurgitation (30 ± 6% vs. 11 ± 1% at 1 year, P < 0.0001). CONCLUSION: Amongst older patients with severe symptomatic DMR at high surgical risk, mitral TEER was associated with higher survival vs. unoperated patients. Successful control of mitral regurgitation was key to survival improvement with mitral TEER, which should be actively considered in patients deemed inoperable.


Subject(s)
Atrial Fibrillation , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Aged , Atrial Fibrillation/complications , Cardiac Catheterization , Heart Valve Prosthesis Implantation/methods , Humans , Mitral Valve Insufficiency/complications , Stroke Volume , Treatment Outcome
11.
Eur Heart J ; 43(7): 641-650, 2022 Feb 12.
Article in English | MEDLINE | ID: mdl-34463727

ABSTRACT

AIMS: Severe mitral regurgitation (MR) following acute myocardial infarction (MI) is associated with high mortality rates and has inconclusive recommendations in clinical guidelines. We aimed to report the international experience of patients with secondary MR following acute MI and compare the outcomes of those treated conservatively, surgically, and percutaneously. METHODS AND RESULTS: Retrospective international registry of consecutive patients with at least moderate-to-severe MR following MI treated in 21 centres in North America, Europe, and the Middle East. The registry included patients treated conservatively and those having surgical mitral valve repair or replacement (SMVR) or percutaneous mitral valve repair (PMVR) using edge-to-edge repair. The primary endpoint was in-hospital mortality. A total of 471 patients were included (43% female, age 73 ± 11 years): 205 underwent interventions, of whom 106 were SMVR and 99 PMVR. Patients who underwent mitral valve intervention were in a worse clinical state (Killip class ≥3 in 60% vs. 43%, P < 0.01), but yet had lower in-hospital and 1-year mortality compared with those treated conservatively [11% vs. 27%, P < 0.01 and 16% vs. 35%, P < 0.01; adjusted hazard ratio (HR) 0.28, 95% confidence interval (CI) 0.18-0.46, P < 0.01]. Surgical mitral valve repair or replacement was performed earlier than PMVR [median of 12 days from MI date (interquartile range 5-19) vs. 19 days (10-40), P < 0.01]. The immediate procedural success did not differ between SMVR and PMVR (92% vs. 93%, P = 0.53). However, in-hospital and 1-year mortality rates were significantly higher in SMVR than in PMVR (16% vs. 6%, P = 0.03 and 31% vs. 17%, P = 0.04; adjusted HR 3.75, 95% CI 1.55-9.07, P < 0.01). CONCLUSIONS: Early intervention may mitigate the poor prognosis associated with conservative therapy in patients with post-MI MR. Percutaneous mitral valve repair can serve as an alternative for surgery in reducing MR for high-risk patients.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Myocardial Infarction , Aged , Aged, 80 and over , Female , Heart Valve Prosthesis Implantation/adverse effects , Humans , Male , Middle Aged , Mitral Valve Insufficiency/complications , Mitral Valve Insufficiency/surgery , Myocardial Infarction/complications , Myocardial Infarction/therapy , Retrospective Studies , Treatment Outcome
12.
J Card Surg ; 37(7): 2053-2059, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35249238

ABSTRACT

INTRODUCTION: The proportion of patients with symptomatic severe aortic stenosis treated by transcatheter aortic valve replacement (TAVR) is increasing, driven by favorable outcomes from randomized trials and current valve guidelines recommendations. Despite device and technique improvements having reduced procedural morbidities, complications during or immediately after TAVR still carries significant mortality risk. METHODS: We propose a check-list of essential items to anticipate potentially life-threatening complications in TAVR. RESULTS: Purpose of this review is to discuss the most common life-threatening complications during TAVR from a troubleshooting perspective, depicting the minimum required equipment needed in emergency situations. CONCLUSIONS: Prevention of complications remains the most important strategy to optimize outcomes in TAVR procedures. Each specialized Center should institute and make easily accessible standardized emergency kits for the most common life-threatening conditions during TAVR that should be readily available in the cath-lab or hybrid operating room.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Aortic Valve/surgery , Aortic Valve Stenosis/complications , Humans , Postoperative Complications/etiology , Risk Factors , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
13.
J Card Surg ; 37(7): 1959-1966, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35385588

ABSTRACT

BACKGROUND: Aim of this study is to analyse the performances of Clinical Risk Score (CRS) and European System for Cardiac Operative Risk Evaluation (EuroSCORE)-II in isolated tricuspid surgery. METHODS: Three hundred and eighty-three patients (54 ± 16 year; 54% female) were enrolled. Receiver operating characteristic analysis was performed to evaluate the relationship between the true positive fraction of test results and the false-positive fraction for a procedure. RESULTS: Considering the 30-day mortality the area under the curve was 0.6 (95% confidence interval [CI] 0.50-0.72) for EuroSCORE II and 0.7 (95% CI 0.56-0.84) for CRS-score. The ratio of expected/observed mortality showed underestimation when considering EuroSCORE-II (min. 0.46-max. 0.6). At multivariate analysis, the CRS score (p = .005) was predictor of late cardiac death. CONCLUSION: We suggest using both scores to obtain a range of expected mortality. CRS to speculate on late survival.


Subject(s)
Cardiac Surgical Procedures , Tricuspid Valve , Female , Hospital Mortality , Humans , Male , ROC Curve , Retrospective Studies , Risk Assessment , Risk Factors , Tricuspid Valve/surgery
14.
J Stroke Cerebrovasc Dis ; 31(9): 106605, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35843052

ABSTRACT

INTRODUCTION: Cerebral embolic protection devices (CEPDs) are designed to prevent embolization of debris during transcatheter aortic valve implantation (TAVI). Current evidence from randomized clinical trials (RCTs) and observational studies is controversial. AIMS: The purpose of this meta-analysis was to study the influence of CEPDs on stroke, silent ischemic lesions and neurocognitive function. METHODS: A systematic search was conducted including RCTs or adjusted observational studies comparing TAVI with or without CEPDs. Pooled odds ratios, risk ratios or standardized mean differences with 95% confidence intervals were calculated using the inverse of variance method. Risk of bias sensitivity analyses and meta regression for CEPD type were also conducted. RESULTS: Five RCTs and five adjusted observational studies were included (n= 159,865). Mean age of the patients was 81.1 (SD 1.04) years in CEPDs and 81 (SD 1.86) in non-CEPD. The overall quality of evidence using the GRADE system for each endpoint was low to very low, mainly due to serious risk of bias, inconsistency and imprecision. Random effects meta-analysis detected no significant differences between CEPD and non-CEPD (OR= 0.74; 95% CI 0.51-1.07; P= 0.105; I2= 82.1%) for 30-day stroke. This finding was consistent in meta regression for CEPD type and subgroup analyses by study type and CEPD type. No significant differences between groups were observed in cerebral DW-MRI assessment and neurocognitive function evaluation. CONCLUSION: In the present meta- analysis of five RCTs and five adjusted observational studies, the use of a CEPD during TAVI was not associated with a significant benefit on 30- day stroke, total lesion volume per patient, number of ischemic lesions per patient and neurocognitive function assessments.


Subject(s)
Embolic Protection Devices , Intracranial Embolism , Stroke , Transcatheter Aortic Valve Replacement , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Humans , Intracranial Embolism/diagnostic imaging , Intracranial Embolism/etiology , Risk Factors , Stroke/diagnosis , Stroke/etiology , Stroke/prevention & control , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
15.
Catheter Cardiovasc Interv ; 97(5): E724-E726, 2021 04 01.
Article in English | MEDLINE | ID: mdl-32154645

ABSTRACT

Transcatheter tricuspid valve intervention (TTVI) is an emerging treatment for patients with symptomatic severe tricuspid regurgitation (TR). Currently, the issues that arise during TTVI are unclear. Here, a 78-year-old woman with severe TR underwent transcatheter tricuspid valve annuloplasty using a Cardioband (Edwards Lifesciences, Irvine, CA). We attempted to cinch the Dacron band after anchoring; however, it was impossible to connect the distal tip of the size adjustment tool and the Dacron band because the cinching wire was tangled around the Dacron band. We resolved this issue without surgical intervention, and eventually cinched the annulus. Final echocardiography revealed dramatic TR reduction. To our knowledge, no study has reported a tangled wire in a Dacron band during Cardioband use. Clinicians should be aware of the risks accompanying this concern in case where it is impossible to connect the distal tip of the size adjustment tool and the Dacron band during cinching.


Subject(s)
Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Aged , Cardiac Catheterization/adverse effects , Female , Heart Valve Prosthesis Implantation/adverse effects , Humans , Polyethylene Terephthalates , Treatment Outcome , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/surgery
16.
Catheter Cardiovasc Interv ; 98(6): E971-E976, 2021 11 15.
Article in English | MEDLINE | ID: mdl-34533899

ABSTRACT

Optimal transseptal puncture (TSP) position on the interatrial septum as well as proper catheter direction and maneuverability in the left atrium (LA) are key elements for successful mitral valve (MV) interventions. TSP is usually performed from the right femoral vein being more comfortable for the operator and easier to reach the fossa ovalis. In the cases reported, TSP was performed from left femoral vein (LFV) to improve delivery system maneuverability and trajectory inside the LA in the context of MV repair with MitraClip. According to this early experience, LFV approach might be considered as first choice or as an alternative solution in patients in whom a higher position of the delivery system relative to the mitral annulus is needed.


Subject(s)
Atrial Septum , Mitral Valve , Atrial Septum/diagnostic imaging , Atrial Septum/surgery , Cardiac Catheterization , Femoral Vein/diagnostic imaging , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Treatment Outcome
17.
Catheter Cardiovasc Interv ; 98(2): E291-E298, 2021 08 01.
Article in English | MEDLINE | ID: mdl-33315296

ABSTRACT

BACKGROUND: Transcatheter aortic valve replacement (TAVR) via transaxillary (TAx) approach with ACURATE neo valve is an off-label procedure. Our aim was to gather information on ACURATE neo cases implanted via TAx approach and report major outcomes. METHODS AND RESULTS: The TRANSAX Study (NCT04274751) retrospectively gathered patients from nine centres in Europe and North America treated with ACURATE neo valve through TAx approach up to May/2019. Follow up was pre-specified at 1-year and was obtained for all patients. A total of 75 patients (79 ± 10 years; 32% women) were included. Left axillary (72%) and conscious sedation (95.2%) were the most common setting. Risk scores were higher when right axillary artery and surgical cut-down were selected. Severe complications including valve embolization, coronary obstruction, annulus rupture, and procedural mortality did not occur. Cardiac tamponade occurred in two cases (2.7%) with one requiring conversion to open surgery (1.3%). Bail-out stenting and surgical vascular repair were required in 7 (9.3%) and 3 (4%) cases, respectively. The need for new permanent pacemaker was 8%. Procedural success (96%), in-hospital (2.7%), and 1-year mortality (8%) were comparable in all settings. Only one case (1.3%) complicated with cerebrovascular event and one (1.3%) presented moderate aortic regurgitation before discharge. CONCLUSIONS: TAx TAVR procedures with the ACURATE neo valve were presented high success rate and low in-hospital and 1-year mortality.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Female , Humans , Male , Prosthesis Design , Retrospective Studies , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
18.
Catheter Cardiovasc Interv ; 98(4): 756-764, 2021 10.
Article in English | MEDLINE | ID: mdl-33991385

ABSTRACT

OBJECTIVES: To evaluate outcome and its predictors of bioprosthetic valve fracture (BVF) in patients undergoing valve-in-valve transcatheter aortic valve replacement (VIV-TAVR). BACKGROUND: BVF is feasible and reduces transvalvular gradients in VIV-TAVR-procedures, but follow-up-data and information on factors influencing the outcome are missing. METHODS: The 81 cases of BVF-VIV-TAVR were collected from 14 international centers. RESULTS: Predominantly transcatheter heart valve (THV) was implanted first, followed by BVF. VARC-2 defined device success was 93%, most failures were attributed to residual high gradients. Mean gradients decreased from 37 ± 13 mmHg to 10.8 ± 5.9 mmHg (p < 0.001). BVF reduced the gradient by 16 mmHg. During follow-up (FU, 281 ± 164 days) mean gradient remained stable (10.8 ± 5.9 mmHg at discharge, 12.4 ± 6.3 mmHg at FU, p = ns). In-hospital major adverse events occurred in 3.7%. Event-free survival at 276 ± 237.6 days was 95.4%. The linear mixed model identified balloon-expandable valves (BEV), Mitroflow surgical valve, stenotic surgical bioprostheses and balloon only 1 mm larger than the true internal diameter of the surgical valve as predictors for higher gradients. CONCLUSIONS: BVF is safe and can significantly reduce gradients, which remain stable at FU. BEV, Mitroflow surgical valve, stenotic bioprostheses and balloon larger than the true internal diameter of the surgical valve of only 1 mm are predictors for higher final gradients.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Follow-Up Studies , Hemodynamics , Humans , Prosthesis Design , Prosthesis Failure , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
19.
Catheter Cardiovasc Interv ; 98(6): E862-E869, 2021 11 15.
Article in English | MEDLINE | ID: mdl-33961729

ABSTRACT

OBJECTIVES: To evaluate the use and outcomes of percutaneous mechanical circulatory support (pMCS) utilized during transcatheter aortic valve implantation (TAVI) from high-volume centers. METHODS AND RESULTS: Our international multicenter registry including 13 high-volume TAVI centers with 87 patients (76.5 ± 11.8 years, 63.2% men) who underwent TAVI for severe aortic stenosis and required pMCS (75.9% VA-ECMO, 19.5% Impella CP, 4.6% TandemHeart) during the procedure (prior to TAVI 39.1%, emergent rescue 50.6%, following TAVI 10.3%). The procedures were considered high-risk, with 50.6% having severe left ventricular dysfunction, 24.1% biventricular dysfunction, and 32.2% severe pulmonary hypertension. In-hospital and 1-year mortality were 27.5% and 49.4%, respectively. Patients with prophylactic hemodynamic support had lower periprocedural mortality compared to patients with rescue insertion of pMCS (log rank = 0.013) and patients who did not undergo cardiopulmonary resuscitation during the TAVI procedure had better short and long term survival (log rank <0.001 and 0.015, respectively). CONCLUSIONS: Given the overall survival rate and low frequency of pMCS-related complications, our study results support the use of pMCS prophylactically or during the course of TAVI (bailout) in order to improve clinical outcomes in high-risk procedures or in case of acute life-threatening hemodynamic collapse.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Female , Humans , Male , Registries , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
20.
Catheter Cardiovasc Interv ; 97(6): 1259-1267, 2021 05 01.
Article in English | MEDLINE | ID: mdl-33600072

ABSTRACT

OBJECTIVES: To assess outcomes in patients with acute mitral regurgitation (MR) following acute myocardial infarction (AMI) who received percutaneous mitral valve repair (PMVR) with the MitraClip device and to compare outcomes of patients who developed cardiogenic shock (CS) to those who did not (non-CS). BACKGROUND: Acute MR after AMI may lead to CS and is associated with high mortality. METHODS: This registry analyzed patients with MR after AMI who were treated with MitraClip at 18 centers within eight countries between January 2016 and February 2020. Patients were stratified into CS and non-CS groups. Primary outcomes were mortality and rehospitalization due to heart failure. Secondary outcomes were acute procedural success, functional improvement, and MR reduction. Multivariable Cox regression analysis evaluated association of CS with clinical outcomes. RESULTS: Among 93 patients analyzed (age 70.3 ± 10.2 years), 50 patients (53.8%) experienced CS before PMVR. Mortality at 30 days (10% CS vs. 2.3% non-CS; p = .212) did not differ between groups. After median follow-up of 7 months (IQR 2.5-17 months), the combined event mortality/re-hospitalization was similar (28% CS vs. 25.6% non-CS; p = .793). Likewise, immediate procedural success (90% CS vs. 93% non-CS; p = .793) and need for reintervention (CS 6% vs. non-CS 2.3%, p = .621) or re-admission due to HF (CS 13% vs. NCS 23%, p = .253) at 3 months did not differ. CS was not independently associated with the combined end-point (hazard ratio 1.1; 95% CI, 0.3-4.6; p = .889). CONCLUSIONS: Patients found to have significant MR during their index hospitalization for AMI had similar clinical outcomes with PMVR whether they presented in or out of cardiogenic shock, provided initial hemodynamic stabilization was first achieved before PMVR.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Myocardial Infarction , Aged , Aged, 80 and over , Heart Valve Prosthesis Implantation/adverse effects , Humans , Middle Aged , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/etiology , Mitral Valve Insufficiency/surgery , Myocardial Infarction/complications , Registries , Shock, Cardiogenic/diagnosis , Shock, Cardiogenic/etiology , Shock, Cardiogenic/therapy , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL