Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
Sensors (Basel) ; 20(5)2020 Mar 03.
Article in English | MEDLINE | ID: mdl-32138331

ABSTRACT

Damage significantly influences response of a strain sensor only if it occurs in the proximity of the sensor. Thus, two-dimensional (2D) sensing sheets covering large areas offer reliable early-stage damage detection for structural health monitoring (SHM) applications. This paper presents a scalable sensing sheet design consisting of a dense array of thin-film resistive strain sensors. The sensing sheet is fabricated using flexible printed circuit board (Flex-PCB) manufacturing process which enables low-cost and high-volume sensors that can cover large areas. The lab tests on an aluminum beam showed the sheet has a gauge factor of 2.1 and has a low drift of 1.5 µ ϵ / d a y . The field test on a pedestrian bridge showed the sheet is sensitive enough to track strain induced by the bridge's temperature variations. The strain measured by the sheet had a root-mean-square (RMS) error of 7 µ ϵ r m s compared to a reference strain on the surface, extrapolated from fiber-optic sensors embedded within the bridge structure. The field tests on an existing crack showed that the sensing sheet can track the early-stage damage growth, where it sensed 600 µ ϵ peak strain, whereas the nearby sensors on a damage-free surface did not observe significant strain change.


Subject(s)
Monitoring, Physiologic/instrumentation , Temperature
2.
J Am Chem Soc ; 137(47): 14842-5, 2015 Dec 02.
Article in English | MEDLINE | ID: mdl-26579554

ABSTRACT

The classical SiO2/Si interface, which is the basis of integrated circuit technology, is prepared by thermal oxidation followed by high temperature (>800 °C) annealing. Here we show that an interface synthesized between titanium dioxide (TiO2) and hydrogen-terminated silicon (H:Si) is a highly efficient solar cell heterojunction that can be prepared under typical laboratory conditions from a simple organometallic precursor. A thin film of TiO2 is grown on the surface of H:Si through a sequence of vapor deposition of titanium tetra(tert-butoxide) (1) and heating to 100 °C. The TiO2 film serves as a hole-blocking layer in a TiO2/Si heterojunction solar cell. Further heating to 250 °C and then treating with a dilute solution of 1 yields a hole surface recombination velocity of 16 cm/s, which is comparable to the best values reported for the classical SiO2/Si interface. The outstanding performance of this heterojunction is attributed to Si-O-Ti bonding at the TiO2/Si interface, which was probed by angle-resolved X-ray photoelectron spectroscopy. Attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR) showed that Si-H bonds remain even after annealing at 250 °C. The ease and scalability of the synthetic route employed and the quality of the interface it provides suggest that this surface chemistry has the potential to enable fundamentally new, efficient silicon solar cell devices.

3.
Adv Funct Mater ; 22(3): 640-651, 2012 Feb 08.
Article in English | MEDLINE | ID: mdl-24093006

ABSTRACT

A high resolution elastically stretchable microelectrode array (SMEA) to interface with neural tissue is described. The SMEA consists of an elastomeric substrate, such as poly(dimethylsiloxane) (PDMS), elastically stretchable gold conductors, and an electrically insulating encapsulating layer in which contact holes are opened. We demonstrate the feasibility of producing contact holes with 40 µm × 40 µm openings, show why the adhesion of the encapsulation layer to the underlying silicone substrate is weakened during contact hole fabrication, and provide remedies. These improvements result in greatly increased fabrication yield and reproducibility. An SMEA with 28 microelectrodes was fabricated. The contact holes (100 µm × 100 µm) in the encapsulation layer are only ~10% the size of the previous generation, allowing a larger number of microelectrodes per unit area, thus affording the capability to interface with a smaller neural population per electrode. This new SMEA is used to record spontaneous and evoked activity in organotypic hippocampal tissue slices at 0% strain before stretching, at 5 % and 10 % equibiaxial strain, and again at 0% strain after relaxation. The noise of the recordings increases with increasing strain. The frequency of spontaneous neural activity also increases when the SMEA is stretched. Upon relaxation, the noise returns to pre-stretch levels, while the frequency of neural activity remains elevated. Stimulus-response curves at each strain level are measured. The SMEA shows excellent biocompatibility for at least two weeks.

4.
IEEE Trans Biomed Circuits Syst ; 13(6): 1264-1276, 2019 12.
Article in English | MEDLINE | ID: mdl-31634845

ABSTRACT

Tactile sensing requires form-fitting and dense sensor arrays over large-areas. Hybrid systems, combining Large-Area Electronics (LAE) and silicon-CMOS ICs to respectively provide diverse sensing and high-performance computation/control, enable a platform for such sensing. A key challenge is that hybrid systems require a large number of interfaces between the LAE and CMOS domains, particularly as the number of sensors scales. This paper presents an architecture that exploits the attribute of signal sparsity, commonly exhibited in large-scale tactile-sensing applications, to reduce the interfacing complexity to a level set by the sparsity rather than the number of sensors. This enhances scalability compared to sequential-scanning and active-matrix approaches. The architecture implements compressed sensing via thin-film-transistor (TFT) switches, and is demonstrated in a force-sensing system with 20 force sensors, a TFT die (with 161 ZnO TFTs) per sensor, and a custom CMOS IC for system readout and control. Acquisition error of 0.7 k[Formula: see text] is achieved over a 100 k Ω-20 k Ω sensing range, at energy and rate of 2.46  µ J/frame and 31 fps.


Subject(s)
Biosensing Techniques/instrumentation , Semiconductors , Skin Physiological Phenomena , Touch/physiology , Transistors, Electronic , Algorithms , Biosensing Techniques/methods , Humans , Silicon/chemistry , Zinc Oxide/chemistry
5.
J Neurotrauma ; 32(13): 1011-9, 2015 Jul 01.
Article in English | MEDLINE | ID: mdl-25517970

ABSTRACT

Traumatic brain injury (TBI) alters function and behavior, which can be characterized by changes in electrophysiological function in vitro. A common cognitive deficit after mild-to-moderate TBI is disruption of persistent working memory, of which the in vitro correlate is long-lasting, neuronal network synchronization that can be induced pharmacologically by the gamma-aminobutyric acid A antagonist, bicuculline. We utilized a novel in vitro platform for TBI research, the stretchable microelectrode array (SMEA), to investigate the effects of TBI on bicuculline-induced, long-lasting network synchronization in the hippocampus. Mechanical stimulation significantly disrupted bicuculline-induced, long-lasting network synchronization 24 h after injury, despite the continued ability of the injured neurons to fire, as revealed by a significant increase in the normalized spontaneous event rate in the dentate gyrus (DG) and CA1. A second challenge with bicuculline 24 h after the first challenge significantly decreased the normalized spontaneous event rate in the DG. In addition, we illustrate the utility of the SMEA for TBI research by combining multiple experimental paradigms in one platform, which has the potential to enable novel investigations into the mechanisms responsible for functional consequences of TBI and speed the rate of drug discovery.


Subject(s)
Bicuculline/pharmacology , Brain Injuries/physiopathology , Electrophysiological Phenomena , GABA-A Receptor Antagonists/pharmacology , Hippocampus/physiopathology , Nerve Net/physiopathology , Neurons/physiology , Animals , Hippocampus/drug effects , In Vitro Techniques , Microelectrodes , Nerve Net/drug effects , Neurons/drug effects , Rats , Rats, Sprague-Dawley
6.
Lab Chip ; 4(5): 473-80, 2004 Oct.
Article in English | MEDLINE | ID: mdl-15472731

ABSTRACT

The design and performance of a miniaturized coplanar capacitive sensor is presented whose electrode arrays can also function as resistive microheaters for thermocapillary actuation of liquid films and droplets. Optimal compromise between large capacitive signal and high spatial resolution is obtained for electrode widths comparable to the liquid film thickness measured, in agreement with supporting numerical simulations which include mutual capacitance effects. An interdigitated, variable width design, allowing for wider central electrodes, increases the capacitive signal for liquid structures with non-uniform height profiles. The capacitive resolution and time response of the current design is approximately 0.03 pF and 10 ms, respectively, which makes possible a number of sensing functions for nanoliter droplets. These include detection of droplet position, size, composition or percentage water uptake for hygroscopic liquids. Its rapid response time allows measurements of the rate of mass loss in evaporating droplets.


Subject(s)
Electric Capacitance , Microfluidics/instrumentation , Capillary Action , Computer Simulation , Electrodes , Equipment Design , Microfluidics/methods , Models, Theoretical , Particle Size , Time Factors , Volatilization
7.
Article in English | MEDLINE | ID: mdl-22256289

ABSTRACT

We have developed two fundamental components to manufacture a prosthetic skin: a stretchable pressure sensor formed of piezoelectric elastomer/ferroelectret multilayer sandwiched between stretchable electrodes and stretchable thin-film transistors. The components are prepared and embedded in silicone rubber, a polymer, which mimics the mechanical compliance of human skin. We demonstrate the stretchability of the sensory unit. In both relaxed and stretched states, the soft sensor skin transduces kPa pressures into electrical currents in the µA range.


Subject(s)
Elasticity , Prostheses and Implants , Skin, Artificial , Electricity , Humans , Naphthacenes/chemistry , Silicone Elastomers/chemistry , Transistors, Electronic
8.
ACS Appl Mater Interfaces ; 2(7): 1927-33, 2010 Jul.
Article in English | MEDLINE | ID: mdl-20608644

ABSTRACT

Gold films on poly(dimethylsiloxane) (PDMS) have applications in stretchable electronics, tunable diffraction gratings, soft lithography and as neural interfaces. The electrical and optical properties of these films depend critically on the morphology of the gold. Therefore, we examine qualitatively and quantitatively the factors that affect the morphology of the gold film. Three morphologies can be produced controllably: microcracked, buckled, and smooth. Which morphology a gold film will adopt depends on the film stress and the growth mode of the film. The factors that affect the film stress and growth mode, and thus the morphology, are as follows: deposition temperature, film thickness, elastic modulus, adhesion layer thickness, surface properties of the PDMS, and mechanical prestrain applied during deposition. We discuss how the different components of the film stress and growth mode of the film affect the morphology.


Subject(s)
Dimethylpolysiloxanes/chemistry , Gold/chemistry , Membranes, Artificial , Stress, Mechanical , Surface Properties
9.
Article in English | MEDLINE | ID: mdl-19964344

ABSTRACT

Sensing neural activity within mechanically active tissues poses particular hurdles because most electrodes are much stiffer than biological tissues. As the tissue deforms, the rigid electrodes may damage the surrounding tissue. The problem is exacerbated when sensing neural activity in experimental models of traumatic brain injury (TBI) which is caused by the rapid and large deformation of brain tissue. We have developed a stretchable microelectrode array (SMEA) that can withstand large elastic deformations (>5% biaxial strain) while continuing to function. The SMEA were fabricated from thin metal conductors patterned on polydimethylsiloxane (PDMS) and encapsulated with a photo-patternable silicone. SMEA were used to record spontaneous activity from brain slice cultures, as well as evoked activity after stimulating through SMEA electrodes. Slices of brain tissue were grown on SMEA in long-term culture and then mechanically injured with our well-characterized in vitro injury model by stretching the SMEA and the adherent culture, which was confirmed by image analysis. Because brain tissue was grown on the substrate-integrated SMEA, post-injury changes in electrophysiological function were normalized to pre-injury function since the SMEA deformed with the tissue and remained in place during mechanical stimulation. The combination of our injury model and SMEA could help elucidate mechanisms responsible for post-traumatic neuronal dysfunction in the quest for TBI therapies. The SMEA may have additional sensing applications in other mechanically active tissues such as peripheral nerve and heart.


Subject(s)
Electrodes, Implanted , Microelectrodes , Animals , Biosensing Techniques , Brain/pathology , Brain Injuries/physiopathology , Brain Mapping/methods , Dimethylpolysiloxanes/chemistry , Electrodes , Electrophysiology/methods , Hippocampus/pathology , Peripheral Nerves/pathology , Rats , Silicones/chemistry , Transducers
10.
J Neurotrauma ; 26(7): 1135-45, 2009 Jul.
Article in English | MEDLINE | ID: mdl-19594385

ABSTRACT

Interfacing electronics and recording electrophysiological activity in mechanically active biological tissues is challenging. This challenge extends to recording neural function of brain tissue in the setting of traumatic brain injury (TBI), which is caused by rapid (within hundreds of milliseconds) and large (greater than 5% strain) brain deformation. Interfacing electrodes must be biocompatible on multiple levels and should deform with the tissue to prevent additional mechanical damage. We describe an elastically stretchable microelectrode array (SMEA) that is capable of undergoing large, biaxial, 2-D stretch while remaining functional. The new SMEA consists of elastically stretchable thin metal films on a silicone membrane. It can stimulate and detect electrical activity from cultured brain tissue (hippocampal slices), before, during, and after large biaxial deformation. We have incorporated the SMEA into a well-characterized in vitro TBI research platform, which reproduces the biomechanics of TBI by stretching the SMEA and the adherent brain slice culture. Mechanical injury parameters, such as strain and strain rate, can be precisely controlled to generate specific levels of damage. The SMEA allowed for quantification of neuronal function both before and after injury, without breaking culture sterility or repositioning the electrodes for the injury event, thus enabling serial and long-term measurements. We report tests of the SMEA and an initial application to study the effect of mechanical stimuli on neuron function, which could be employed as a high-content, drug-screening platform for TBI.


Subject(s)
Electrophysiology/instrumentation , Hippocampus/physiology , Microelectrodes , Neurons/physiology , Animals , Electric Stimulation , Electrophysiology/methods , Evoked Potentials/physiology , Rats
12.
Conf Proc IEEE Eng Med Biol Soc ; Suppl: 6732-5, 2006.
Article in English | MEDLINE | ID: mdl-17959498

ABSTRACT

Traumatic brain injury (TBI) can be caused by motor vehicle accidents, falls and firearms. TBI can result in major neurological dysfunction such as chronic seizures and memory disturbances. To discover mechanisms of functional deficits underlying TBI, we developed a stretchable microelectrode array (SMEA),which can be used for continuous recording of neuronal function, pre-, during, and post-stretch injury. TheSMEA was fabricated on a polydimethylsiloxane (PDMS)substrate with stretchable, 100 pm wide, 25 nm thick gold electrodes patterned there on [1]. The electrodes were encapsulated with a 10-20 microm thick, photo-patternable PDMS insulation layer. Previous biocompatibility tests showed no overt necrosis or cell death caused by the SMEAs after 2 weeks in culture [2]. The electrical performance of the SMEAs was tested in electrophysiological saline solution before, during and after biaxial stretching. The results showed that the electrode impedance increased with the strain to reach 800 kL at 8.5% strain and then recovered to 10 kil after relaxation. The working noise level remained below 20 pV pp during the whole process. New methodologiesf or improving the patterning of the encapsulation layer were tested on gold electrode arrays supported on glass. With these prototype arrays, robust population spikes were recorded from organotypic hippocampal slice cultures of brain tissue. Additionally, seizure-like activity induced with 1 mM bicuculline was also recorded. Our results demonstrate that the prototype arrays have good electrical performance compatible with existing multielectrode array systems. They also indicate the ability to record neuronal activity from hippocampal slices. This novel technology will enable new studies to understand injury mechanisms leading to post-traumatic neuronal dysfunction.


Subject(s)
Brain Injuries/physiopathology , Neurons/physiology , Action Potentials , Animals , Dimethylpolysiloxanes , Hippocampus/physiopathology , Microelectrodes , Organ Culture Techniques , Silicones , Stress, Mechanical
SELECTION OF CITATIONS
SEARCH DETAIL