Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 120
Filter
1.
Proc Natl Acad Sci U S A ; 119(17): e2120439119, 2022 04 26.
Article in English | MEDLINE | ID: mdl-35412862

ABSTRACT

Long-duration spaceflight induces changes to the brain and cerebrospinal fluid compartments and visual acuity problems known as spaceflight-associated neuro-ocular syndrome (SANS). The clinical relevance of these changes and whether they equally affect crews of different space agencies remain unknown. We used MRI to analyze the alterations occurring in the perivascular spaces (PVS) in NASA and European Space Agency astronauts and Roscosmos cosmonauts after a 6-mo spaceflight on the International Space Station (ISS). We found increased volume of basal ganglia PVS and white matter PVS (WM-PVS) after spaceflight, which was more prominent in the NASA crew than the Roscosmos crew. Moreover, both crews demonstrated a similar degree of lateral ventricle enlargement and decreased subarachnoid space at the vertex, which was correlated with WM-PVS enlargement. As all crews experienced the same environment aboard the ISS, the differences in WM-PVS enlargement may have been due to, among other factors, differences in the use of countermeasures and high-resistive exercise regimes, which can influence brain fluid redistribution. Moreover, NASA astronauts who developed SANS had greater pre- and postflight WM-PVS volumes than those unaffected. These results provide evidence for a potential link between WM-PVS fluid and SANS.


Subject(s)
Astronauts , Cerebrospinal Fluid , Glymphatic System , Space Flight , Vision Disorders , Cerebrospinal Fluid/diagnostic imaging , Glymphatic System/diagnostic imaging , Humans , Magnetic Resonance Imaging , Vision Disorders/cerebrospinal fluid , Vision Disorders/diagnostic imaging , White Matter/diagnostic imaging
2.
Neuroradiology ; 64(5): 1011-1020, 2022 May.
Article in English | MEDLINE | ID: mdl-35149883

ABSTRACT

PURPOSE: Heavily T2-weighted 3D FLAIR (hT2w-3D-FLAIR) sequence with constant flip angle (CFA) has been reported as being more sensitive to low concentrations of gadolinium (Gd) enabling endolymphatic hydrops (EH) visualization. The purpose of this study was to compare signal-to-noise (SNR) ratio, detection rate of EH, and increased perilymphatic enhancement (PE) as well as diagnostic accuracy in diagnosing definite Menière's disease (MD), using 3D-SPACE FLAIR versus conventional 3D-TSE FLAIR. METHODS: This retrospective study included 29 definite MD patients who underwent a 4-h delayed intravenous (IV) Gd-enhanced 3D-TSE FLAIR and 3D-SPACE FLAIR MRI between February 2019 and February 2020. MR images were qualitatively and quantitatively analyzed twice by 2 experienced head and neck radiologists. Qualitative assessment included grading of cochlear and vestibular EH and visual comparison of PE. Quantitative assessment of PE was performed by placing a region of interest (ROI) and ratio calculation in the basal turn of the cochlea and the brainstem. RESULTS: The intra- and inter-reader reliability for grading of EH and PE was excellent (0.7 < kappa < 0.9) for 3D-SPACE FLAIR and exceeded the values for 3D-TSE FLAIR (0.5 < kappa < 0.9) The combination of EH and visual assessment of PE has the highest diagnostic accuracy in diagnosing definite MD on 3D-SPACE FLAIR with a sensitivity of 0.91 and a specificity of 0.98 resulting in a sensitivity raise of 6% compared to 3D-TSE FLAIR. CONCLUSION: Four-hour delayed IV Gd-enhanced 3D-SPACE FLAIR sequence has a higher sensitivity and reproducibility than 3D-TSE FLAIR for the visualization of EH and increased PE in definite MD patients.


Subject(s)
Endolymphatic Hydrops , Meniere Disease , Contrast Media , Endolymphatic Hydrops/diagnostic imaging , Gadolinium , Humans , Imaging, Three-Dimensional , Magnetic Resonance Imaging/methods , Meniere Disease/diagnostic imaging , Reproducibility of Results , Retrospective Studies
3.
Ear Hear ; 43(5): 1502-1514, 2022.
Article in English | MEDLINE | ID: mdl-35030554

ABSTRACT

OBJECTIVES: Based on limited evidence from case reports and small cohort studies of metal-on-metal (MoM) hip implant patients with presumed systemic cobalt (Co) toxicity, and a few animal studies on Co-induced damage to the otovestibular system, it was hypothesised that Co exhibits an ototoxic potential alongside other systemic manifestations. Preliminary investigations from our research group in MoM patients confirmed this assumption for the auditory system, whereas no signs of Co-induced vestibular impairment were detected, and a clear dose-response relationship between the auditory function and the blood Co levels was lacking. Therefore, the current study aimed to extend and validate these findings in a larger sample of MoM patients and control subjects, to explore the potential clinical value of audiovestibular outcome measures in the risk estimation of systemic Co toxicity in this patient population. DESIGN: Fifty patients (32 to 68 years) with a primary unilateral/bilateral MoM hip implant were matched for age, gender, and noise exposure to 50 nonimplanted control subjects. Both groups underwent the same protocol, consisting of an objective auditory [i.e., conventional and high-frequency audiometry, transient-evoked and distortion (TEOAEs and DPOAEs), auditory brainstem responses] and vestibular (i.e., cervical and ocular vestibular evoked myogenic potentials, horizontal and vertical video head impulse tests) test battery, a questionnaire inquiring auditory, balance, and general neurological symptoms, and a blood sample collection to determine the plasma Co concentration. RESULTS: The auditory test battery presented consistently higher audiometric thresholds in the MoM patient group, with group differences ranging from 2.1 to 5.7 dB in the lower frequencies (0.25 to 6.0 kHz) and from 4.6 to 9.3 dB in the high frequencies (8.0 to 14.0 kHz). Group differences at high frequencies were statistically significant ( p ≤ 0.001). Additionally, significantly lower TEOAE ( p = 0.009) and DPOAE ( p < 0.001) amplitudes were observed in the MoM patients when the better ear was included in the analysis, and more absent TEOAE and DPOAE responses were found between 1.0 and 4.0 kHz (0.008 ≤ p ≤ 0.039). Within the vestibular test battery, the MoM patients showed longer N1 and P1 ocular vestibular evoked myogenic potentials latencies for the left ear, and lower video head impulse test gains for the left anterior and right posterior semicircular canals (0.005 ≤ p ≤0.035). The patient-reported (questionnaire) outcome delivered no significant group differences ( p > 0.01). Six patients had elevated Co levels according to our local institutional threshold (>4 or 5 µg/l for unilateral or bilateral MoM hip implants, resp.), but their audiovestibular outcome measures did not differ significantly from those of the other patients. CONCLUSIONS: Corresponding to our preliminary investigations, the results indicate possibly Co-induced (predominantly high-frequency) auditory impairment, probably triggered by toxic damage to the cochlear structures. However, the low mean difference values, the lack of group differences for the patient-reported outcome measures, and the lack of any relationship with the blood Co levels strongly reduce the clinical relevance of these findings. Therefore, the risk of Co-induced ototoxic impairment is considered to be clinically negligible for the majority of MoM hip implant patients, and the use of auditory tests in the risk estimation of systemic Co toxicity should be decided on a case-by-case basis.


Subject(s)
Hip Prosthesis , Metal-on-Metal Joint Prostheses , Audiometry, Pure-Tone , Cobalt , Hip Prosthesis/adverse effects , Humans , Metal-on-Metal Joint Prostheses/adverse effects , Metals , Patient Reported Outcome Measures
4.
Proc Natl Acad Sci U S A ; 116(21): 10531-10536, 2019 05 21.
Article in English | MEDLINE | ID: mdl-31061119

ABSTRACT

Long-duration spaceflight induces detrimental changes in human physiology. Its residual effects and mechanisms remain unclear. We prospectively investigated the changes in cerebrospinal fluid (CSF) volume of the brain ventricular regions in space crew by means of a region of interest analysis on structural brain scans. Cosmonaut MRI data were investigated preflight (n = 11), postflight (n = 11), and at long-term follow-up 7 mo after landing (n = 7). Post hoc analyses revealed a significant difference between preflight and postflight values for all supratentorial ventricular structures, i.e., lateral ventricle (mean % change ± SE = 13.3 ± 1.9), third ventricle (mean % change ± SE = 10.4 ± 1.1), and the total ventricular volume (mean % change ± SE = 11.6 ± 1.5) (all P < 0.0001), with higher volumes at postflight. At follow-up, these structures did not quite reach baseline levels, with still residual increases in volume for the lateral ventricle (mean % change ± SE = 7.7 ± 1.6; P = 0.0009), the third ventricle (mean % change ± SE = 4.7 ± 1.3; P = 0.0063), and the total ventricular volume (mean % change ± SE = 6.4 ± 1.3; P = 0.0008). This spatiotemporal pattern of CSF compartment enlargement and recovery points to a reduced CSF resorption in microgravity as the underlying cause. Our results warrant more detailed and longer longitudinal follow-up. The clinical impact of our findings on the long-term cosmonauts' health and their relation to ocular changes reported in space travelers requires further prospective studies.


Subject(s)
Cerebral Ventricles , Space Flight , Adult , Case-Control Studies , Cerebral Ventricles/diagnostic imaging , Humans , Magnetic Resonance Imaging , Middle Aged , Prospective Studies
5.
Eur Arch Otorhinolaryngol ; 279(12): 5615-5621, 2022 Dec.
Article in English | MEDLINE | ID: mdl-35499623

ABSTRACT

PURPOSE: To evaluate the efficacy and safety of a titanium total prosthesis (TORP) in ossicular chain reconstruction. METHODS: Retrospective analysis of 113 cases of total ossicular chain reconstruction performed by a single surgeon between 2006 and 2018. Follow-up lasted until January 2020. Participants were patients with chronic otitis media, cholesteatoma, or ossicular chain disruption. RESULTS: Mean preoperative air-bone gap (± standard deviation) was 32.74 dB (± 11.62). Mean postoperative air-bone gap was 21.68 (± 11.29). Mean air-bone gap improvement was 11.06 dB (± 14.99) (p < 0.001). 57 cases had a post-operative air-bone gap smaller than or equal to 20 dB (50.44%). In four cases, prosthesis dislocation was observed (12.39%). Mean prosthesis length in this group was 5.29 mm (± 0.86) versus 4.36 mm (± 1.02) in cases without prosthesis dislocation (p = 0.002). CONCLUSIONS: Total ossicular reconstruction using a titanium prosthesis yields favorable functional results, also during prolonged follow-up. Prosthesis length was significantly longer in cases with prosthesis dislocation.


Subject(s)
Ossicular Prosthesis , Ossicular Replacement , Humans , Ossicular Replacement/methods , Titanium , Retrospective Studies , Treatment Outcome
6.
Eur Arch Otorhinolaryngol ; 278(6): 1755-1763, 2021 Jun.
Article in English | MEDLINE | ID: mdl-32757037

ABSTRACT

PURPOSE: To create an index that is a measure of the amount of vestibular compensation and for which only functional balance performance is needed. METHODS: The medical charts of 62 eligible peripheral vestibular dysfunction (PVD) patients were analyzed retrospectively. To be included, the following vestibulo-ocular reflex (VOR) and balance performance data had to be available: (1) caloric and sinusoidal harmonic acceleration test (SHA) and (2) standing balance sum-eyes closed (SBS-EC), Timed Up and Go Test and Dynamic Gait Index. Patients were divided into three groups: normal caloric- and SHA test (group 1), abnormal caloric- and normal SHA test (group 2, PVD compensated) and abnormal caloric- and SHA test (group 3, PVD uncompensated). Next to the use of non-parametric tests to study the VOR and balance variables, logistic regression was used to identify the balance measures that predict whether PVD patients were compensated or uncompensated. This resulted also in the construction of a continuous measure representing the degree of compensation. RESULTS: Logistic regression identified SBS-EC and age to classify uncompensated from compensated patients with sensitivity of 83.9% and specificity of 72.4%. Then an index was created, called the Antwerp Vestibular Compensation Index, AVeCI = - 50 + age × 0.486 + SBS-EC × 0.421. A patient belongs to the uncompensated group when AVeCI < 0 and to the compensated group when AVeCI > 0, with respective group means of - 5 and 5. CONCLUSION: AVeCI stages the degree of compensation of PVD patients and can serve to evaluate rehabilitation effects.


Subject(s)
Caloric Tests , Vestibular Diseases , Humans , Postural Balance , Reflex, Vestibulo-Ocular , Retrospective Studies , Time and Motion Studies , Vestibular Diseases/diagnosis , Vestibular Function Tests
7.
Eur Arch Otorhinolaryngol ; 278(12): 4783-4793, 2021 Dec.
Article in English | MEDLINE | ID: mdl-33492418

ABSTRACT

PURPOSE: In this retrospective study the relationship between cochleovestibular function and a magnetic resonance imaging (MRI-) based classification system of endolymphatic hydrops was investigated. METHODS: Seventy-eight patients with unilateral definite Menière's disease who underwent MRI were included. The parameters of Pure Tone Audiometry (PTA), caloric irrigation test, cervical vestibular evoked myogenic potentials, and video Head Impulse Test were compared between the grades of endolymphatic hydrops (EH) and perilymphatic enhancement (PE) on MRI. RESULTS: The low-frequency PTA was significantly different between cochlear EH grades I and II (p = 0.036; Grade I: mean (Standard Deviation, SD) = 51 decibel Hearing Level (dB HL) (18 dB HL); Grade II: mean (SD) = 60 dB HL (16 dB HL)), and vestibular EH grades 0 and III (p = 0.018; Grade 0: mean (SD) = 43 dB HL (21 dB HL); Grade III: mean = 60 dB HL (10 dB HL)). The ipsilateral caloric sum of ears with vestibular EH grade I (n = 6) was increased with regards to vestibular EH grades 0 (p = 0.001), II (p < 0.001), and III (p < 0.001) (Grade 0: mean (SD) = 24°/s (15°/s); Grade I: mean (SD) = 47°/s (11°/s); Grade II: mean (SD) = 21°/s (13°/s); Grade III: mean (SD) = 16°/s (8°/s)). CONCLUSION: According to these results we can conclude that only the highest grades of cochlear and vestibular EH seem to be associated with decreased cochleovestibular functioning.


Subject(s)
Endolymphatic Hydrops , Meniere Disease , Vestibular Evoked Myogenic Potentials , Endolymphatic Hydrops/diagnostic imaging , Humans , Magnetic Resonance Imaging , Meniere Disease/diagnostic imaging , Retrospective Studies
8.
Int J Audiol ; 60(1): 44-53, 2021 01.
Article in English | MEDLINE | ID: mdl-32687006

ABSTRACT

OBJECTIVE: This study aimed to systematically investigate the ototoxic potential of cobalt in patients with a metal-on-metal (MoM) hip implant, using objective auditory and vestibular assessments and a questionnaire. The results of the objective evaluation were published previously, whereas the current study focused on the questionnaire outcome and its relationship to the blood cobalt level. Design and study sample: Twenty patients (33-65 years) with a primary MoM hip implant and 20 non-implanted control subjects, matched for age, gender, and noise exposure, received a questionnaire to evaluate the presence of several hearing and balance symptoms (part 1) and general neurological issues (part 2). RESULTS: Concerning part 1, the proportion of auditory-related symptoms in general (p = 0.022) and tinnitus (p = 0.047) was significantly higher in the MoM patient group, whereas no group difference was found for hyperacusis, increased listening effort, and decreased speech understanding. Concerning part 2, no significant group differences were detected. Within the MoM patient group, the questionnaire outcome was not significantly different between the low-exposure and high-exposure subgroups according to the blood Co level. CONCLUSIONS: In line with our previous study, these results potentially imply Co-induced impairment to the auditory system, despite the lack of a clear dose-response relationship.


Subject(s)
Arthroplasty, Replacement, Hip , Metal-on-Metal Joint Prostheses , Cobalt/toxicity , Humans , Patient Reported Outcome Measures , Pilot Projects , Prosthesis Design
9.
Audiol Neurootol ; 25(1-2): 35-41, 2020.
Article in English | MEDLINE | ID: mdl-31927546

ABSTRACT

BACKGROUND: The peripheral vestibular end organ is considered to consist of semi-circular canals (SCC) for detection of angular accelerations and the otoliths for detection of linear accelerations. However, otoliths being phylogenetically the oldest part of the vestibular sensory organs are involved in detection of all motions. SUMMARY: This study elaborates on this property of the otolith organ, as this concept can be of importance for the currently designed vestibular implant devices. Key Message: The analysis of the evolution of the inner ear and examination of clinical examples shows the robustness of the otolith system and inhibition capacity of the SCC. The otolith system must be considered superior to the SCC system as illustrated by evolution, clinical evidence, and physical principles.


Subject(s)
Otolithic Membrane/physiology , Reflex, Vestibulo-Ocular/physiology , Vestibule, Labyrinth/physiology , Humans , Saccule and Utricle/physiology , Semicircular Canals/physiology
10.
Ear Hear ; 41(1): 217-230, 2020.
Article in English | MEDLINE | ID: mdl-31169566

ABSTRACT

OBJECTIVES: During the past decade, the initial popularity of metal-on-metal (MoM) hip implants has shown a progressive decline due to increasingly reported implant failure and revision surgeries. Local as well as systemic toxic side effects have been associated with excessive metal ion release from implants, in which cobalt (Co) plays an important role. The rare condition of systemic cobaltism seems to manifest as a clinical syndrome with cardiac, endocrine, and neurological symptoms, including hearing loss, tinnitus, and imbalance. In most cases described in the literature, revision surgery and the subsequent drop in blood Co level led to (partial) alleviation of the symptoms, suggesting a causal relationship with Co exposure. Moreover, the ototoxic potential of Co has recently been demonstrated in animal experiments. Since its ototoxic potential in humans is merely based on anecdotal case reports, the current study aimed to prospectively and objectively examine the auditory and vestibular function in patients implanted with a MoM hip prosthesis. DESIGN: Twenty patients (15 males and 5 females, aged between 33 and 65 years) implanted with a primary MoM hip prosthesis were matched for age, gender, and noise exposure to 20 non-implanted control subjects. Each participant was subjected to an extensive auditory (conventional and high-frequency pure tone audiometry, transient evoked and distortion product otoacoustic emissions [TEOAEs and DPOAEs], auditory brainstem responses [ABR]) and vestibular test battery (cervical and ocular vestibular evoked myogenic potentials [cVEMPs and oVEMPs], rotatory test, caloric test, video head impulse test [vHIT]), supplemented with a blood sample collection to determine the plasma Co concentration. RESULTS: The median [interquartile range] plasma Co concentration was 1.40 [0.70, 6.30] µg/L in the MoM patient group and 0.19 [0.09, 0.34] µg/L in the control group. Within the auditory test battery, a clear trend was observed toward higher audiometric thresholds (11.2 to 16 kHz), lower DPOAE (between 4 and 8 kHz), and total TEOAE (1 to 4 kHz) amplitudes, and a higher interaural latency difference for wave V of the ABR in the patient versus control group (0.01 ≤ p < 0.05). Within the vestibular test battery, considerably longer cVEMP P1 latencies, higher oVEMP amplitudes (0.01 ≤ p < 0.05), and lower asymmetry ratio of the vHIT gain (p < 0.01) were found in the MoM patients. In the patient group, no suggestive association was observed between the plasma Co level and the auditory or vestibular outcome parameters. CONCLUSIONS: The auditory results seem to reflect signs of Co-induced damage to the hearing function in the high frequencies. This corresponds to previous findings on drug-induced ototoxicity and the recent animal experiments with Co, which identified the basal cochlear outer hair cells as primary targets and indicated that the cellular mechanisms underlying the toxicity might be similar. The vestibular outcomes of the current study are inconclusive and require further elaboration, especially with respect to animal studies. The lack of a clear dose-response relationship may question the clinical relevance of our results, but recent findings in MoM hip implant patients have confirmed that this relationship can be complicated by many patient-specific factors.


Subject(s)
Hip Prosthesis , Metal-on-Metal Joint Prostheses , Ototoxicity , Adult , Aged , Audiometry, Pure-Tone , Auditory Threshold , Cobalt , Evoked Potentials, Auditory, Brain Stem , Female , Hip Prosthesis/adverse effects , Humans , Male , Metal-on-Metal Joint Prostheses/adverse effects , Middle Aged , Otoacoustic Emissions, Spontaneous
12.
Neuroradiology ; 61(4): 421-429, 2019 Apr.
Article in English | MEDLINE | ID: mdl-30719545

ABSTRACT

PURPOSE: There is still a clinical-radiologic discrepancy in patients with Menière's disease (MD). Therefore, the purpose of this study was to investigate the reliability of current MRI endolymphatic hydrops (EH) criteria according to Baráth in a larger study population and the clinical utility of new imaging signs such as a supplementary fourth low-grade vestibular EH and the degree of perilymphatic enhancement (PE) in patients with Menière's disease (MD). METHODS: This retrospective study included 148 patients with probable or definite MD according to the 2015 American Academy of Otolaryngology, Head and Neck Surgery criteria who underwent a 4-h delayed intravenous Gd-enhanced 3D-FLAIR MRI between January 2015 and December 2016. Vestibular EH, vestibular PE, cochlear EH, and cochlear PE were reviewed twice by three experienced readers. Cohen's Kappa and multivariate logistic regression were used for analysis. RESULTS: The intra- and inter-reader reliability for the grading of vestibular-cochlear EH and PE was excellent (0.7 < kappa < 0.9). The two most distinctive characteristics to identify MD are cochlear PE and vestibular EH which combined gave a sensitivity and specificity of 79.5 and 93.6%. By addition of a lower grade vestibular EH, the sensitivity improved to 84.6% without losing specificity (92.3%). Cochlear EH nor vestibular PE showed added-value. CONCLUSIONS: MRI using vestibular-cochlear EH and PE grading system is a reliable technique. A four-stage vestibular EH grading system in combination with cochlear PE assessment gives the best diagnostic accuracy to detect MD.


Subject(s)
Magnetic Resonance Imaging/methods , Meniere Disease/diagnostic imaging , Adult , Aged , Aged, 80 and over , Contrast Media , Diagnosis, Differential , Female , Humans , Image Interpretation, Computer-Assisted , Imaging, Three-Dimensional , Male , Meniere Disease/classification , Middle Aged , Organometallic Compounds , Perilymph/diagnostic imaging , Reproducibility of Results , Retrospective Studies
13.
J Neurophysiol ; 117(3): 903-909, 2017 03 01.
Article in English | MEDLINE | ID: mdl-27903640

ABSTRACT

The objectives of this study were 1) to probe the effects of visual motion adaptation on early visual and V5/MT cortical excitability and 2) to investigate whether changes in cortical excitability following visual motion adaptation are related to the degree of visual dependency, i.e., an overreliance on visual cues compared with vestibular or proprioceptive cues. Participants were exposed to a roll motion visual stimulus before, during, and after visual motion adaptation. At these stages, 20 transcranial magnetic stimulation (TMS) pulses at phosphene threshold values were applied over early visual and V5/MT cortical areas from which the probability of eliciting a phosphene was calculated. Before and after adaptation, participants aligned the subjective visual vertical in front of the roll motion stimulus as a marker of visual dependency. During adaptation, early visual cortex excitability decreased whereas V5/MT excitability increased. After adaptation, both early visual and V5/MT excitability were increased. The roll motion-induced tilt of the subjective visual vertical (visual dependence) was not influenced by visual motion adaptation and did not correlate with phosphene threshold or visual cortex excitability. We conclude that early visual and V5/MT cortical excitability is differentially affected by visual motion adaptation. Furthermore, excitability in the early or late visual cortex is not associated with an increase in visual reliance during spatial orientation. Our findings complement earlier studies that have probed visual cortical excitability following motion adaptation and highlight the differential role of the early visual cortex and V5/MT in visual motion processing.NEW & NOTEWORTHY We examined the influence of visual motion adaptation on visual cortex excitability and found a differential effect in V1/V2 compared with V5/MT. Changes in visual excitability following motion adaptation were not related to the degree of an individual's visual dependency.


Subject(s)
Adaptation, Physiological , Motion Perception , Visual Cortex/physiology , Adult , Cortical Excitability , Female , Humans , Male , Phosphenes , Photic Stimulation , Transcranial Magnetic Stimulation , Young Adult
14.
Ear Hear ; 38(2): 205-211, 2017.
Article in English | MEDLINE | ID: mdl-27787395

ABSTRACT

OBJECTIVES: This study was performed to compare three electrode configurations for the ocular vestibular evoked myogenic potentials (oVEMPs)-"standard," "sternum," and "nose"-by making use of bone-conducted stimuli (at the level of Fz with a minishaker). In the second part, we compared the test-retest reliability of the standard and nose electrode configuration on the oVEMP parameters. DESIGN: This study had a prospective design. Fourteen healthy subjects participated in the first part (4 males, 10 females; average age = 23.4 (SD = 2.6) years; age range 19.9 to 28.3 years) and second part (3 males, 11 females; average age = 22.7 (SD = 2.4) years; age range 20.0 to 28.0 years) of the study. OVEMPs were recorded making use of a hand-held bone conduction vibrator (minishaker). Tone bursts of 500 Hz (rise/fall time = 2 msec; plateau time = 2 msec; repetition rate = 5.1 Hz) were applied at a constant stimulus intensity level of 140 dB FL. RESULTS: PART 1: The n10-p15 amplitude obtained with the standard electrode configuration (mean = 15.8 µV; SD = 6.3 µV) was significantly smaller than the amplitude measured with the nose (Z = -3.3; p = 0.001; mean = 35.0 µV; SD = 19.1 µV) and sternum (Z = -3.3; p = 0.001; mean = 27.1 µV; SD = 12.2 µV) electrode configuration. The p15 latency obtained with the nose electrode configuration (mean = 14.2 msec; SD = 0.54 msec) was significantly shorter than the p15 latency measured with the standard (Z = -3.08; p = 0.002) (mean = 14.9 msec; SD = 0.75 msec) and sternum (Z = -2.98; p = 0.003; mean = 15.4 msec; SD = 1.07 msec) electrode configuration. There were no differences between the n10 latencies of the three electrode configurations. The 95% prediction intervals (given by the mean ± 1.96 * SD) for the different interocular ratio values were [-41.2; 41.2], [-37.2; 37.2], and [-25.9; 25.9] for standard, sternum, and nose electrode configurations, respectively. PART 2: Intraclass correlation (ICC) values calculated for the oVEMP parameters obtained with the standard electrode configuration showed fair to good reliability for the parameters n10-p15 amplitude (ICC = 0.51), n10 (ICC = 0.52), and p15 (ICC = 0.60) latencies. The ICC values obtained for the parameters acquired with the nose electrode configuration demonstrated a poor reliability for the n10 latency (ICC = 0.37), a fair to good reliability for the p15 latency (ICC = 0.47) and an excellent reliability for the n10-p15 amplitude (ICC = 0.85). CONCLUSIONS: This study showed the possible benefits from alternative electrode configurations for measuring bone-conducted-evoked oVEMPs in comparison with the standard electrode configuration. The nose configuration seems promising, but further research is required to justify clinical use of this placement.


Subject(s)
Bone Conduction/physiology , Electrodes , Vestibular Evoked Myogenic Potentials/physiology , Vibration , Adult , Female , Healthy Volunteers , Humans , Male , Prospective Studies , Reproducibility of Results , Young Adult
15.
Ear Hear ; 38(6): 653-662, 2017.
Article in English | MEDLINE | ID: mdl-28650850

ABSTRACT

OBJECTIVES: This systematic review aimed to investigate the prevalence and characteristics of vestibular adverse effects of aminoglycoside (AG) therapy in humans and to analyze objective vestibular tests for the detection of AG-induced vestibulotoxicity. DESIGN: PubMed, Cochrane Database, Web of Science, and reference lists of all included studies were screened by two independent researchers. The Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines were followed. Studies were included according to preset inclusion criteria and reported outcomes of studies evaluating vestibular function using one or more objective vestibular function tests in adults and children after systemic AG administration. The methodological quality of each study was assessed using the quality assessment tool for quantitative studies. Interrater reliability was established using Cohen's Kappa. RESULTS: Twenty-seven studies were included, with the vast majority showing AG-induced vestibulotoxic side effects, ranging from 0 to 60%. Most studies reported AG-induced abnormalities by caloric and rotatory testing, whereas only a few studies reported using video Head Impulse test and vestibular evoked myogenic potential testing. CONCLUSIONS: Because type I hair cells (particularly of the semicircular canals) are more susceptible to ototoxicity, video Head Impulse test and vestibular evoked myogenic potential testing seem more promising for the early detection of vestibulotoxicity than caloric and rotatory testing. Prospective studies using an extensive vestibular test battery are needed to further characterize the impact of AGs on the different vestibular end organs and to identify the most sensitive vestibular technique for the early detection of vestibulotoxicity.


Subject(s)
Aminoglycosides/adverse effects , Vestibular Diseases/chemically induced , Caloric Tests , Head Impulse Test , Humans , Vestibular Diseases/epidemiology , Vestibular Diseases/physiopathology , Vestibular Evoked Myogenic Potentials/physiology , Vestibular Function Tests
18.
J Neurophysiol ; 115(6): 3045-51, 2016 06 01.
Article in English | MEDLINE | ID: mdl-27009158

ABSTRACT

The information coming from the vestibular otolith organs is important for the brain when reflexively making appropriate visual and spinal corrections to maintain balance. Symptoms related to failed balance control and navigation are commonly observed in astronauts returning from space. To investigate the effect of microgravity exposure on the otoliths, we studied the otolith-mediated responses elicited by centrifugation in a group of 25 astronauts before and after 6 mo of spaceflight. Ocular counterrolling (OCR) is an otolith-driven reflex that is sensitive to head tilt with regard to gravity and tilts of the gravito-inertial acceleration vector during centrifugation. When comparing pre- and postflight OCR, we found a statistically significant decrease of the OCR response upon return. Nine days after return, the OCR was back at preflight level, indicating a full recovery. Our large study sample allows for more general physiological conclusions about the effect of prolonged microgravity on the otolith system. A deconditioned otolith system is thought to be the cause of several of the negative effects seen in returning astronauts, such as spatial disorientation and orthostatic intolerance. This knowledge should be taken into account for future long-term space missions.


Subject(s)
Astronauts , Eye Movements/physiology , Otolithic Membrane/physiology , Reflex, Vestibulo-Ocular/physiology , Space Flight , Weightlessness , Adult , Chi-Square Distribution , Female , Humans , Male , Middle Aged , Rotation , Time Factors
20.
Int J Audiol ; 55(3): 189-94, 2016.
Article in English | MEDLINE | ID: mdl-26624575

ABSTRACT

OBJECTIVE: The purpose of this paper was to provide an extensive description of a case of sopite syndrome, a manifestation of motion sickness scarcely described in the literature. DESIGN: The following questionnaires were used to assess sopite syndrome symptoms pre, during and post parabolic flight; Misery Scale rate, Positive and Negative Affect Scale, the Motion Sickness Assessment Questionnaire and the Epworth Sleepiness Scale. STUDY SAMPLE: Case report of a 35-year old female compared to a control group (n = 26). RESULTS: We describe of sopite syndrome during parabolic flight. The subject reported drowsiness and she noted mood changes such as irritation and annoyance. Furthermore, she was not able to perform her assigned task. Her symptoms escalated into extreme fatigue and the inability to stay awake. Nauseogenic symptoms improved, but soporific symptoms persisted for several hours after the motion stimulus (i.e. parabolic flight). CONCLUSIONS: This case points towards the need for controlled studies to assess the prevalence of this syndrome among the general population and select groups. Future research should focus on developing tests for personnel screening and explore treatment options.


Subject(s)
Space Motion Sickness , Adult , Case-Control Studies , Female , Humans , Male
SELECTION OF CITATIONS
SEARCH DETAIL