Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 77
Filter
1.
J Cardiovasc Electrophysiol ; 35(3): 488-497, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38254339

ABSTRACT

Transcatheter aortic valve replacement (TAVR) often leads to conduction abnormalities, necessitating pacemaker implantation. This review of 38 meta-analyses identified preexisting right bundle branch block (RBBB), LAHB, and new-onset left bundle branch block as key risk factors, with a higher PPM risk in male and older patients. Procedural factors like transfemoral access and self-expandable valves also increase this risk. Prevention focuses on tailoring TAVR to individual electrophysiological and anatomical profiles. However, there's a lack of consensus in managing these conduction disturbances post-TAVR, highlighting the need for further research and standardized treatment strategies.


Subject(s)
Aortic Valve Stenosis , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Male , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , Aortic Valve Stenosis/surgery , Risk Factors , Pacemaker, Artificial/adverse effects , Bundle-Branch Block/diagnosis , Bundle-Branch Block/etiology , Bundle-Branch Block/prevention & control , Aortic Valve/surgery
2.
Catheter Cardiovasc Interv ; 102(6): 1140-1148, 2023 11.
Article in English | MEDLINE | ID: mdl-37668110

ABSTRACT

BACKGROUND: Preprocedural computed tomography planning improves procedural safety and efficacy of transcatheter aortic valve implantation (TAVI). However, contemporary imaging modalities do not account for device-host interactions. AIMS: This study evaluates the value of preprocedural computer simulation with FEops HEARTguideTM on overall device success in patients with challenging anatomies undergoing TAVI with a contemporary self-expanding supra-annular transcatheter heart valve. METHODS: This prospective multicenter observational study included patients with a challenging anatomy defined as bicuspid aortic valve, small annulus or severely calcified aortic valve. We compared the heart team's transcatheter heart valve (THV) planning decision based on (1) conventional multislice computed tomography (MSCT) and (2) MSCT imaging with FEops HEARTguideTM simulations. Clinical outcomes and THV performance were followed up to 30 days. RESULTS: A total of 77 patients were included (median age 79.9 years (IQR 74.2-83.8), 42% male). In 35% of the patients, preprocedural planning changed after FEops HEARTguideTM simulations (change in valve size selection [12%] or target implantation height [23%]). A new permanent pacemaker implantation (PPI) was implanted in 13% and >trace paravalvular leakage (PVL) occurred in 28.5%. The contact pressure index (i.e., simulation output indicating the risk of conduction abnormalities) was significantly higher in patients with a new PPI, compared to those without (16.0% [25th-75th percentile 12.0-21.0] vs. 3.5% [25th-75th percentile 0-11.3], p < 0.01) The predicted PVL was 5.7 mL/s (25th-75th percentile 1.3-11.1) in patients with none-trace PVL, 12.7 (25th-75th percentile 5.5-19.1) in mild PVL and 17.7 (25th-75th percentile 3.6-19.4) in moderate PVL (p = 0.04). CONCLUSION: FEops HEARTguideTM simulations may provide enhanced insights in the risk for PVL or PPI after TAVI with a self-expanding supra-annular THV in complex anatomies.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Male , Aged , Aged, 80 and over , Female , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Computer Simulation , Prospective Studies , Treatment Outcome , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Multidetector Computed Tomography/methods , Prosthesis Design
3.
J Pharm Pharm Sci ; 26: 11208, 2023.
Article in English | MEDLINE | ID: mdl-36942295

ABSTRACT

Purpose: Remdesivir use in COVID-19 is associated with cardiac conduction abnormalities from unclear mechanisms. A proposed mechanism is the bioaccumulation of the intermediate metabolite GS-441524 resulting in exogenous activation of cardiac adenosine A1 due to the structural similarity between adenosine and GS-441524. The prolonged half-life of GS-441524 can result in sustained activation of adenosine A1 receptors. In this study, we used molecular modeling of adenosine, GS-441524 and the adenosine A1 receptor to assess the potential mechanistic association of the proposed mechanism. Methods: Adenosine and GS-441524 structures were acquired from the PubChem database. Ligand docking was carried out using UCSF Chimera. Models were chosen based on greatest binding affinity and minimum root mean square deviation. Figures of resulting structural models were prepared using UCSF Chimera or PyMOL 2.3.5. Results: By modeling the interaction between the A1 G protein complex and both adenosine and GS-441524, we found that the proposed mechanism of exogenous A1 receptor activation is feasible based on docking compatibility. Conclusion: The proposed mechanism of exogenous cardiac A1 receptor activation from bioaccumulation of GS-441524 as a cause of observed cardiac conduction abnormalities with the use of remdesivir in COVID-19 is viable. Further studies are needed to assess causality.


Subject(s)
COVID-19 , Humans , COVID-19 Drug Treatment , Adenosine Monophosphate , Adenosine
4.
Cardiol Young ; 33(4): 525-531, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36688288

ABSTRACT

OBJECTIVES: Cardiac manifestations of the coronavirus disease 2019 (COVID-19) have mainly been reported in adults. Therefore, we aimed to determine the electrocardiographic abnormalities in hospitalised paediatric patients with COVID-19 and multisystemic inflammatory syndrome in children. METHODS: We retrospectively evaluated hospitalised paediatric patients <18 years of age with a diagnosis of COVID-19 (n = 168) and multisystem inflammatory syndrome in children (n = 48) between March 2021 and December 2021. A daily electrocardiography was performed for the patients who had electrocardiographic abnormalities on admission or developed electrocardiographic abnormality on the follow-up. The characteristics of these patients, underlying predisposing conditions, and clinical course were also examined. RESULTS: Two-hundred sixteen paediatric patients (55% were male) with a mean age of 10.7 ± 4.69 years were evaluated. There was an underlying disease in 84 (38.8%) patients and 51 (23.6%) required paediatric ICU admission. Electrocardiography abnormality was detected in 12 (5.5%) which were as follows: 7 (3.2%) had sinus bradycardia, 3 (1.4%) patients had transient ST elevation and concomitant T negativity, and 2 (0.9%) developed first-degree Atrioventricular (AV) block. The median time from the onset of disease symptoms to detecting electrocardiographic abnormality was 9 days. Electrocardiographic abnormalities returned to normal uneventfully 3 days later. CONCLUSIONS: The prevalence of arrhythmia in paediatric patients with COVID-19 was detected in 5.5% of the patients. While two-thirds of the electrocardiography abnormalities were sinus bradycardia, ST elevation was remarkable (1.4%). Clinicians should be aware of electrocardiographic abnormalities and consider electrocardiographic monitoring in paediatric patients with COVID-19 and multisystemic inflammatory syndrome in children.


Subject(s)
Atrioventricular Block , COVID-19 , ST Elevation Myocardial Infarction , Adult , Humans , Male , Child , Adolescent , Female , COVID-19/complications , COVID-19/diagnosis , Bradycardia , Retrospective Studies , Child, Hospitalized , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/epidemiology , Arrhythmias, Cardiac/etiology , Atrioventricular Block/diagnosis , Electrocardiography , Syndrome
5.
Catheter Cardiovasc Interv ; 100(2): 245-253, 2022 08.
Article in English | MEDLINE | ID: mdl-35758231

ABSTRACT

OBJECTIVE: To examine the rate of readmission for permanent pacemaker (PPM) implantation with early versus late discharge after transcatheter aortic valve replacement (TAVR). BACKGROUND: There is a current trend toward early discharge after TAVR. However, paucity of data exists on the impact of such practice on readmissions for PPM implantation. METHODS: The Nationwide Readmission Database 2016-2018 was queried for all hospitalizations where patients underwent TAVR. Hospitalizations were stratified into early (Days 0 and 1) versus late (≥Day 2) discharge groups. Observations in which PPM was required in the index admission were excluded. Multivariable regression analyses involving patient- and hospital-related variables were utilized. The primary outcome was 90-day readmission for PPM implantation. RESULTS: The final analysis included 68,482 TAVR hospitalizations, 20,261 (29.6%) with early versus 48,221 (70.4%) with late discharge. Early discharge after TAVR increased over the study period (16.2% in 2016 vs. 37.9% in 2018, Ptrend < 0.01). Nevertheless, 90-day readmission for PPM implantation remained stable (1.8% in 2016 vs. 2.0% in 2018, Ptrend = 0.32). The 90-day readmission rate for PPM implantation (2.0% vs. 1.8%; adjusted odds ratio: 1.15; 95% confidence interval: 0.95-1.39; p = 0.15) and median time-to-readmission (5 days [interquartile range, IQR 3-9] vs. 5 days [IQR 3-14], p = 0.92) were similar with early versus late discharge. Similar rates were observed regardless of whether readmission was elective versus not. Early discharge was associated with lower hospitalization cost ($39,990 ± $13,681 vs. $46,750 ± $18,218, p < 0.01) compared with late discharge. CONCLUSION: In patients who did not require PPM during the index TAVR hospitalization, the rate of readmission for PPM implantation was similar with early versus late discharge.


Subject(s)
Aortic Valve Stenosis , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Humans , Patient Discharge , Patient Readmission , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
6.
Catheter Cardiovasc Interv ; 100(5): 868-876, 2022 11.
Article in English | MEDLINE | ID: mdl-36073020

ABSTRACT

OBJECTIVES: To assess the inter methodological agreement of membrane septum (MS) length measurement and additive value for risk stratification of new pacemaker implantation (PMI) over the established predictors after transcatheter aortic valve replacement (TAVR). BACKGROUND: Recent studies have suggested MS length and implantation depth (ID) as predictors for PMI after TAVR. However, the measurement of MS length is neither uniform nor validated in different cohort. METHODS: We retrospectively analyzed patients who underwent TAVR at five centers. The MS length was measured by two previously proposed methods (coronal and annular view method). Predictive ability of risk factors, including MS length and ID, for new PMI within 30 days after TAVR were evaluated. RESULTS: Among 754 patients of study population, 31 patients (4.1%) required new PMI within 30 days of TAVR. There was a weak correlation (ρ = 0.47) and a poor agreement between the two methods. The ID and the difference between MS length and ID (ΔMSID), were independent predictors for new PMI, whereas MS length alone was not. Further, for predicting new PMI after TAVR, discrimination performance was not significantly improved when MS length was added to the model with ID alone (integrated discrimination improvement = 0, p= 0.99; continuous net-reclassification improvement = 0.10, p= 0.62). CONCLUSIONS: External validity and predictive accuracy of MS length for PMI after TAVR were not sufficient to provide better risk stratification over the established predictors in our cohort. Moreover, the ID and ΔMSID, but not MS length alone, are predictive of future PMI after TAVR.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/etiology , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Retrospective Studies , Reproducibility of Results , Cardiac Pacing, Artificial/adverse effects , Treatment Outcome , Risk Factors
7.
Pacing Clin Electrophysiol ; 45(1): 103-110, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34727374

ABSTRACT

BACKGROUND: Permanent pacemaker (PPM) implantation is a common complication of transcatheter aortic valve implantation (TAVI). The optimum timing of PPM implantation is still unclear as conduction abnormalities evolve and a balance needs to be struck between conservative delays in the hope of conduction recovery and overutilization of pacing. This study aimed to assess the safety and efficacy of early PPM implantation, without an observation period, among TAVI patients. METHODS: This is a retrospective, observational study of 1398 TAVI patients. Clinical and pacing data were collected at baseline, 30 days and at a median of 15 (4-21) months post-TAVI. Study endpoints included PPM-related complications, pacing utilization and hospital length of stay. RESULTS: One hundred five patients (8.2%) required a PPM, of which 13 were implanted pre and 92 post-TAVI. Seventy-six percent required pacing for either second- or third-degree heart block. Time to implantation for post-TAVI PPM was 1 (0-3) day. Six patients experienced a pacing-related complication- lead displacement (n = 3), hematoma (n = 2), and device infection (n = 1). Pacing utilization defined as pacing >10% of the time or a pacing requirement at the time of the pacing check was demonstrated in 83% of patients. Multivariate analysis revealed complete heart block (CHB) was the only independent predictor of pacing utilization. Hospital length of stay for the post-TAVI PPM group was longer than the group without PPM (4 [2-8] vs. 3 [2-4] days; p < .001). CONCLUSIONS: Early PPM implantation in TAVI patients is safe and majority of patients require pacing in the short and mid-term.


Subject(s)
Cardiac Pacing, Artificial , Pacemaker, Artificial , Postoperative Complications/prevention & control , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Female , Humans , Length of Stay/statistics & numerical data , Male , Retrospective Studies
8.
Europace ; 23(23 Suppl 1): i105-i112, 2021 03 04.
Article in English | MEDLINE | ID: mdl-33751080

ABSTRACT

AIMS: Cardiac dyssynchrony in patients with repaired Tetralogy of Fallot (rToF) has been attributed to right bundle branch block (RBBB), fibrosis and/or the patches that are inserted during repair surgery. We aimed to investigate the basis of abnormal activation in rToF patients by mapping the electrical activation sequence during sinus rhythm (SR) and right ventricular (RV) pacing. METHODS AND RESULTS: A total of 17 patients were studied [13 with rToF, 2 with left bundle branch block (LBBB), and 2 without RBBB or LBBB (non-BBB)] during medically indicated cardiac surgery. During SR and RV pacing, measurements were performed using 112-electrode RV endocardial balloons (rToF only) and biventricular epicardial sock arrays (four of the rToF and all non-rToF patients). During SR, functional lines of block occurred in five rToF patients, while RV pacing caused functional blocks in four rToF patients. The line of block persisted during both SR and RV pacing in only 2 out of 13 rToF patients. Compared to SR, RV pacing increased dispersion of septal activation, but not dispersion of endocardial and epicardial activation of the RV free wall. During pacing, RV and left ventricular activation dispersion in rToF patients were comparable to that of the non-rToF patients. CONCLUSION: The results of the present study indicate that the delayed activation in the right ventricle of rToF patients is predominantly due to block(s) in the Purkinje system and that conduction in RV tissue is fairly normal.


Subject(s)
Tetralogy of Fallot , Arrhythmias, Cardiac , Bundle-Branch Block/diagnosis , Bundle-Branch Block/etiology , Heart Rate , Heart Ventricles/diagnostic imaging , Humans , Tetralogy of Fallot/surgery
9.
Postepy Dermatol Alergol ; 38(2): 269-273, 2021 Apr.
Article in English | MEDLINE | ID: mdl-34408595

ABSTRACT

INTRODUCTION: It has been claimed that patients with systemic sclerosis (SSc) have an increased risk of developing cardiac arrhythmias and atrioventricular conduction disorders, but it is unknown whether SSc may be a cause of sinoatrial conduction abnormalities. AIM: To establish the incidence of sinoatrial conduction abnormalities in patients with SSc and verify the relationship of these disorders with various clinical descriptors of SSc. MATERIAL AND METHODS: Forty women with systemic sclerosis of varying duration and severity underwent 24-hour ambulatory ECG monitoring. The occurrence of type I second-degree sinoatrial block (SA-block) and calculation of sinoatrial conduction time (SACT) were evaluated to establish the incidence of sinoatrial conduction abnormalities. The measurements of SACT were obtained using spontaneous atrial premature beats. The effect of various clinical descriptors on sinoatrial conduction abnormalities was assessed. RESULTS: The mean ± SD SACT for the 40 patients was 150 ±15 ms. Prolonged (> 150 ms) SACT was found in 20 patients. In 14 (35%) patients SA-block occurred during ambulatory ECG monitoring. The discriminant analysis identified the severity of SSc cutaneous manifestation as an independent marker for developing SA-block (p < 0.005) and SACT prolongation (p < 0.0002). CONCLUSIONS: Patients with SSc are at an increased risk of developing type I second-degree sinoatrial block and prolonged sinoatrial conduction time. The occurrence of these abnormalities is related to the severity of skin involvement. Therefore, cardiological diagnosis using 24-hour ambulatory ECG in this group of patients should be focused also on this type of disorders. Prospective, controlled studies are needed to assess their prognostic role.

10.
J Cardiovasc Electrophysiol ; 31(4): 943-951, 2020 04.
Article in English | MEDLINE | ID: mdl-32057165

ABSTRACT

INTRODUCTION: Intra-atrial conduction abnormalities are associated with the development of atrial fibrillation (AF) and cause morphological changes of the unipolar atrial electrogram (U-AEGM). This study examined the impact of different atrial programmed electrical stimulation (APES) protocols on U-AEGM morphology to identify the most optimal APES protocol provoking conduction abnormalities. METHODS: APES techniques (14 protocols) were applied in 30 patients referred for an electrophysiology study, consisting of fixed rate, extra, and decremental stimuli at different frequencies. U-AEGM morphologies including width, amplitude, and fractionation for patients without (control group) and with a history of AF (AF group) were examined during APES. In addition, sinus rhythm (SR) U-AEGMs preceding different APES protocols were compared to evaluate the morphology stability over time. RESULTS: U-AEGM morphologies during SR before the APES protocols were comparable (all P > .396). Atrial refractoriness was longer in the AF group compared to the control group (298 ± 48 vs 255 ± 33 ms; P ≤ .020), but did not differ between AF patients with and without amiodarone therapy (278 ± 48 vs 311 ± 40 ms; P ≥ .126). Compared to the initial SR morphology, U-AEGM width, amplitude, and fractionation changed significantly during the 14 different APES protocols, particularly in the AF group. In both groups, U-AEGM changes in morphology were most pronounced during fixed-rate stimulation with extra stimuli (8S1-S2 = 400-250 ms). CONCLUSION: APES results in significant changes in U-AEGM morphology, including width, amplitude, and fractionation. The impact of APES differed between APES sequence and between patients with and without AF. These findings suggest that APES could be useful to identify AF-related conduction abnormalities in the individual patient.


Subject(s)
Action Potentials , Atrial Fibrillation/diagnosis , Atrial Function , Cardiac Pacing, Artificial , Electrophysiologic Techniques, Cardiac , Heart Rate , Adolescent , Adult , Aged , Aged, 80 and over , Atrial Fibrillation/physiopathology , Case-Control Studies , Child , Databases, Factual , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Refractory Period, Electrophysiological , Time Factors , Young Adult
11.
Epilepsy Behav ; 94: 59-64, 2019 05.
Article in English | MEDLINE | ID: mdl-30884409

ABSTRACT

PURPOSE: Juvenile neuronal ceroid lipofuscinosis (CLN3 disease) is the most common neurodegenerative disorder in childhood with survival until young adult age. Visual loss is followed by epilepsy, cognitive, neuropsychiatric, and motor symptoms. We have studied the evolution of electroencephalographic (EEG) and seizure characteristics. METHODS: Twenty-four patients were recruited via the Norwegian CLN3 disease parent association. Parents were interviewed. Medical records and EEG reports/recordings were collected. Electroencephalographic elements were classified according to Standardized computer-based organized reporting of EEG (SCORE). The evolution of EEG features along with seizure types was assessed by testing the difference in proportions with standardized normal deviate comparing findings below and above 15 years of age. RESULTS: Mean age at study or death (n = 12) was 21.2 (10-39) years. Twenty-two patients had experienced seizures; the first was usually bilateral tonic-clonic (TC). Later, focal motor seizures frequently occurred, often with increasing multifocal and polymorphic features. Paroxysmal nonepileptic motor and autonomous symptoms were also suspected in several patients. Distinct myoclonic seizures were uncommon. In four patients, we identified episodes of bradycardia/sinus arrest. Electroencephalography showed progressive slowing of the background activity (p = 0.029). Focal epileptiform discharges were rare and mainly seen at age <10. Combined multifocal and bilateral epileptiform discharges increased in adolescence (p = 0.002). CONCLUSION: Seizure and EEG characteristics change with time in CLN3 disease. Tonic-clonic seizures are common at onset, and multifocal motor seizures increase with age. In contrast, focal epileptiform abnormalities are more common in childhood, compared to later multifocal and bilateral discharges. This seizure disorder belongs to the combined generalized and focal epilepsies. Paucity of myoclonic seizures does not warrant classification as a classic progressive myoclonic epilepsy. When attacks with only behavior arrest occur, cardiac conduction abnormalities should be considered.


Subject(s)
Epilepsy/diagnosis , Neuronal Ceroid-Lipofuscinoses/complications , Seizures/diagnosis , Adolescent , Adult , Child , Disease Progression , Electroencephalography , Epilepsy/physiopathology , Female , Humans , Male , Membrane Glycoproteins , Molecular Chaperones , Neuronal Ceroid-Lipofuscinoses/physiopathology , Seizures/physiopathology , Young Adult
12.
Pacing Clin Electrophysiol ; 41(9): 1266-1267, 2018 09.
Article in English | MEDLINE | ID: mdl-29893417

ABSTRACT

Transcatheter aortic valve implantation (TAVI) has become an established treatment option for aortic valve stenosis in patients with a high risk for conventional surgical valve replacement. A well-known complication is the development of conduction abnormalities. In the case of a new third-degree atrioventricular block, the complication can be life-threatening and permanent pacing is needed. Often these patients have a venous sheath placed in the jugular vein for the perioperative period. We report a case of inadvertent dislodgement of a permanent pacemaker lead after removal of a preoperatively placed venous sheath in a TAVI patient.


Subject(s)
Aortic Valve Stenosis/surgery , Atrioventricular Block/surgery , Device Removal/adverse effects , Electrodes, Implanted/adverse effects , Pacemaker, Artificial/adverse effects , Transcatheter Aortic Valve Replacement , Aged, 80 and over , Echocardiography , Humans , Iatrogenic Disease , Male
13.
Pacing Clin Electrophysiol ; 41(1): 81-86, 2018 01.
Article in English | MEDLINE | ID: mdl-29205396

ABSTRACT

BACKGROUND: Cardiac conduction abnormalities requiring permanent pacemaker (PPM) implantation are major complications of transcatheter aortic valve replacement (TAVR). We aimed to investigate whether the relationship between prosthetic valve size and cardiac-gated computed tomography (CT)-based aortic root complex measurements can aid in recognizing patients at risk for PPM implantation post-TAVR. METHODS: We included 83 of 114 consecutive patients who underwent TAVR with the Edwards Sapien valve (Edwards Lifesciences, Irving, CA, USA) at our institution. We excluded patients with preexisting PPM, patients who required conversion to an open surgical procedure, and patients without CT data. We assessed the significance of various potential predictors of PPM placement post-TAVR. RESULTS: Following TAVR, eight patients (9.6%) required PPM. Prosthetic valve to sinus of Valsalva (SOV) index was significantly higher in those patients requiring a PPM post-TAVR (84.1 ± 9.3 vs 76.8 ± 7.1, P  =  0.009). CONCLUSIONS: The prosthetic valve size to diameter of SOV index was identified as a novel predictor of PPM implantation after TAVR.


Subject(s)
Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/surgery , Cardiac-Gated Imaging Techniques , Heart Valve Prosthesis , Pacemaker, Artificial , Tomography, X-Ray Computed , Transcatheter Aortic Valve Replacement , Aged, 80 and over , Female , Humans , Male , Retrospective Studies , Treatment Outcome
14.
Echocardiography ; 33(11): 1785-1787, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27539479

ABSTRACT

Ankylosing spondylitis often involves a heart, such as aortic or mitral regurgitation, conduction disorder, or cardiomyopathy. We present a 34-year-old male patient with ankylosing spondylitis who has severe aortic regurgitation, mild mitral stenosis, and a conduction disturbance of the left bundle branch block, identified using multimodal images.


Subject(s)
Aortic Valve Insufficiency/etiology , Bundle-Branch Block/etiology , Echocardiography, Transesophageal/methods , Electrocardiography/methods , Mitral Valve Insufficiency/etiology , Multimodal Imaging/methods , Spondylitis, Ankylosing/complications , Adult , Aortic Valve Insufficiency/diagnosis , Bundle-Branch Block/diagnosis , Humans , Male , Mitral Valve Insufficiency/diagnosis
15.
Front Cardiovasc Med ; 11: 1370244, 2024.
Article in English | MEDLINE | ID: mdl-38650916

ABSTRACT

Transcatheter aortic valve replacement (TAVR) has increasingly become a safe, feasible, and widely accepted alternative surgical treatment for patients with severe symptomatic aortic stenosis. However, the incidence of conduction abnormalities associated with TAVR, including left bundle branch block (LBBB) and high-degree atrioventricular block (HAVB), remains high and is often correlated with risk factors such as the severity of valvular calcification, preexisting conditions in patients, and procedural factors. The existing research results on the impact of post-TAVR conduction abnormalities and permanent pacemaker (PPM) requirements on prognosis, including all-cause mortality and rehospitalization, remain contradictory, with varied management strategies for post-TAVR conduction system diseases across different institutions. This review integrates the latest research in the field, offering a comprehensive discussion of the mechanisms, risk factors, consequences, and management of post-TAVR conduction abnormalities. This study provides insights into optimizing patient prognosis and explores the potential of novel strategies, such as conduction system pacing, to minimize the risk of adverse clinical outcomes.

16.
World J Cardiol ; 16(4): 168-172, 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38690219

ABSTRACT

Pacemaker post-transcatheter aortic valve replacement is related to multifactorial risk. Nwaedozie et al brought to the body of evidence electrocardiogram and clinical findings. However, procedural characteristics have at least as much impact on the final need for a permanent pacemaker and potentially on the pacing rate. In this regard, long-term follow-up and understanding of the impact of long-term stimulation is of utmost importance.

17.
Cureus ; 16(2): e55211, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38425331

ABSTRACT

This case report aims to highlight an atypical presentation of deceleration-dependent aberrancy (DDA) following the induction of general anesthesia in a patient with no known cardiac history. It emphasizes the critical role of intraoperative monitoring and the potential effects of anesthetic agents on the cardiac conduction system. A 46-year-old Hispanic male with no significant past medical or surgical history presented for surgical repair of a comminuted radial fracture. Following anesthesia induction with propofol, midazolam, and fentanyl, he developed a transient left bundle branch block (LBBB) exhibiting deceleration-dependent characteristics. Despite stable hemodynamics, the LBBB pattern appeared at heart rates below 60 beats per minute and resolved with heart rates above 90 beats per minute. This was managed intraoperatively with glycopyrrolate. Postoperative evaluations, including a 12-lead ECG, echocardiogram, and nuclear stress test, indicated normal biventricular function with a small to moderate reversible perfusion defect. The patient did not report cardiac symptoms postoperatively and did not prefer to undergo a coronary angiogram. This report underscores the importance of recognizing rate-dependent LBBB as a potential intraoperative complication, even in patients without pre-existing cardiac conditions. The transient nature of DDA, influenced by anesthetic agents and managed through careful monitoring and pharmacological intervention, highlights the necessity for vigilance in perioperative settings. This case contributes to a growing body of evidence suggesting that anesthetic management may require tailored approaches for patients experiencing or at risk for conduction abnormalities. This case illustrates the complexities of cardiac conduction disturbances such as DDA in the context of general anesthesia, serving as a reminder of the importance of thorough monitoring and the judicious use of rate-modifying drugs. It fosters a deeper understanding of the interaction between anesthesia and cardiac electrophysiology. Further research is needed to explore the mechanisms and management strategies for anesthetic-related cardiac conduction abnormalities.

18.
Int J Cardiol ; 377: 26-32, 2023 04 15.
Article in English | MEDLINE | ID: mdl-36640966

ABSTRACT

BACKGROUND: Cardiac tamponade caused by temporary right ventricular (RV) pacemaker perforation is a rare but serious complication in transcatheter aortic valve replacement (TAVR). AIMS: To study the incidence of temporary pacemaker related cardiac tamponade in TAVR, and the relation to the type of pacemaker lead used in periprocedural temporary transvenous pacing. METHODS: A single center registry of transfemoral TAVRs in 2014-2020. Main inclusion criterion was peri-operative use of a temporary RV pacing lead. Main exclusion criteria were a preoperatively implanted permanent pacemaker or the exclusive use of left ventricular guidewire pacing. Incident cardiac tamponade was classified as pacemaker lead related, or other. Patients were grouped according to type of temporary RV pacing wire. RESULTS: 810 patients were included (age 80.5 ± 7.3 [mean ± standard deviation], female 319, 39.4%). Of these, 566 (69.9%) received a standard RV temporary pacing wire (RV-TPW), and 244 (30.1%) received temporary RV pacing through a permanent, passive pacemaker lead (RV-TPPL). In total, 18 (2.2%) events of cardiac tamponade occurred, 12 (67%) were pacemaker lead related. All pacemaker lead-related cardiac tamponades occurred in the group who received a standard RV-TPW and none in the group who received RV-TPPL (n = 12 [2.1%] vs. n = 0 [0%], p = 0.022). No difference in cardiac tamponade due to other causes was seen between the groups (p = 0.82). CONCLUSIONS: The use of soft-tip RV-TPPL was associated with a lower risk of pacemaker related cardiac tamponade in TAVR. When perioperative pacing is indicated, temporary RV-TPPL may contribute to a significant reduction of cardiac tamponade in TAVR.


Subject(s)
Aortic Valve Stenosis , Cardiac Tamponade , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Female , Aged , Aged, 80 and over , Transcatheter Aortic Valve Replacement/adverse effects , Cardiac Tamponade/diagnosis , Cardiac Tamponade/epidemiology , Cardiac Tamponade/etiology , Treatment Outcome , Pacemaker, Artificial/adverse effects , Cardiac Pacing, Artificial , Aortic Valve Stenosis/surgery , Risk Factors , Aortic Valve/surgery
19.
Cureus ; 15(6): e41175, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37525790

ABSTRACT

Cardiac sarcoidosis is a rare complication of pulmonary sarcoidosis, causing granulomatous inflammation of the myocardium, ultimately resulting in infiltrative cardiomyopathy. Through fibrotic inflammation, cardiac sarcoidosis predisposes patients to multiple complications, such as conduction abnormalities, ventricular arrhythmias, heart failure, and sudden cardiac death. Due to the adverse prognosis of conduction abnormalities in these patients, dual chamber implantable cardiac defibrillator (ICD) therapy is beneficial in reducing mortality and morbidity. Early ICD placement can prevent further immune-driven fibrotic conduction complications. Here we present a case of a 50-year-old female who underwent ICD placement due to conduction abnormalities secondary to cardiac sarcoidosis.

20.
J Cardiovasc Dev Dis ; 10(11)2023 Nov 19.
Article in English | MEDLINE | ID: mdl-37998527

ABSTRACT

Transcatheter aortic valve implantation (TAVI) is an established alternative to surgery in patients with symptomatic severe aortic stenosis and has expanded its indications to even low-surgical-risk patients. Conduction abnormalities (CA) and permanent pacemaker (PPM) implantations remain a relatively common finding post TAVI due to the close proximity of the conduction system to the aortic root. New onset left bundle branch block (LBBB) and high-grade atrioventricular block are the most commonly reported CA post TAVI. The overall rate of PPM implantation post TAVI varies and is related to pre- and intra-procedural factors. Therefore, when screening patients for TAVI, Heart Teams should take under consideration the various anatomical, pathophysiological and procedural conditions that predispose to CA and PPM requirement after the procedure. This is particularly important as TAVI is being offered to younger patients with longer life-expectancy. Herein, we highlight the incidence, predictors, impact and management of CA in patients undergoing TAVI.

SELECTION OF CITATIONS
SEARCH DETAIL