Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.628
Filter
Add more filters

Publication year range
1.
Microvasc Res ; 152: 104641, 2024 03.
Article in English | MEDLINE | ID: mdl-38072161

ABSTRACT

BACKGROUND: Renal Resistive Index (RRI) is an important and non-invasive parameter of renal damage and it is associated with abnormal microcirculation or to a parenchymal injury. The aim of our study was to compare the RRI in a cohort of patients with renal diseases categorized in three groups: nephrotic syndrome (NS), acute nephritic syndrome (ANS) and patients with urinary abnormalities (UA). METHODS: Four hundred eighty-two patients with median age of 48 years (IQR 34-62) with indications for kidney disease were included in the study. Biochemical analyses, clinical assessment with detection of NS, ANS and UA and comorbidities were reported. Renal Doppler ultrasound with RRI was evaluated in all patients at the time of enrolment. RESULTS: NS was present in 81 (16.8 %) patients while ANS in 81 (16.8 %) and UA in 228 (47.3 %) patients. Patients with ANS showed significant higher RRI compared to both patients with NS [0.71 (IQR 0.67-0.78) vs 0.68 (0.63-0.73), p < 0.001] and UA [0.71 (0.67-0.78) vs 0.65 (0.61-0.71), p < 0.001]; RRI was higher in NS patients than in patients with UA [0.68 (0.63-0.73) vs 0.65 (0.61-0.71), p < 0.001]. Patients with ANS had significantly lower median estimated glomerular filtration rate (eGFR) compared respectively to NS and UA patients [19.7 ml/min vs 54.8 ml/min and vs 72.3 ml/min, p < 0.001], while renal length was significantly higher in patients with NS compared to both patients with ANS and UA [111.88 mm vs 101.98 mm and vs 106.15, p < 0.001]. Patients with ANS had more frequently hematuria and RRI ≥ 0.70 (p < 0.001) compared to both patients with NS and patients with UA. The multiple regression analysis, weighted for age, showed that RRI inversely correlates with eGFR (ß coefficient = -0.430, p < 0.001). CONCLUSIONS: Higher and pathological RRI were found in ANS than NS and UA. Renal resistive index in ANS reflects changes in intrarenal perfusion and microvascular dysfunction related to disease characteristics.


Subject(s)
Hematuria , Kidney Diseases , Humans , Adult , Middle Aged , Microcirculation , Kidney/blood supply , Ultrasonography, Doppler
2.
Eur J Clin Invest ; 54(1): e14091, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37675595

ABSTRACT

BACKGROUND: The vasculature function is mainly regulated by the autonomic nervous system. Importantly, the sensory-motor nervous system also innervates peripheral vessels and has the capacity to modulate vascular tone. Here we investigated the effects of electrical stimulation of a mixed nerve trunk on blood flow in deep arteries and muscle perfusion. Our hypothesis is that stimulation of a mixed nerve can modify blood flow. METHODS: Twenty-nine healthy participants were included into a randomized-crossover and blinded clinical trial. Each subject received a placebo and two percutaneous peripheral nerve stimulation (pPNS) protocols on the median nerve: Pain Threshold continuous Low Frequency (PT-cLF) and Sensory Threshold burst High Frequency (ST-bHF). Blood flow was then assessed bilaterally using Power Doppler Ultrasonography at the main arteries of the arm, and blood perfusion at the forearm muscles. Afterwards, blood flow was quantified using a semi-automatized software, freely shared here. RESULTS: Placebo, consisting in needle insertion, produced an immediate and generalized reduction on peak systolic velocity in all arteries. Although nerve stimulation produced mainly no effects, some significant differences were found: both protocols increased the relative perfusion area of the forearm muscles, the ST-bHF protocol prevented the reduction in peak systolic velocity and TAMEAN of the radial artery produced by the control protocol and PT-cLF produced a TAMEAN reduction of the ulnar artery. CONCLUSIONS: Therefore, the arterial blood flow in the arm is mainly impervious to the electrical stimulation of the median nerve, composed by autonomic and sensory-motor axons, although it produces mild modifications in the forearm muscles perfusion.


Subject(s)
Forearm , Hemodynamics , Humans , Radial Artery/innervation , Radial Artery/physiology , Muscle, Skeletal , Peripheral Nerves/physiology , Blood Flow Velocity
3.
BMC Cancer ; 24(1): 224, 2024 Feb 16.
Article in English | MEDLINE | ID: mdl-38365653

ABSTRACT

BACKGROUND: Breast ultrasound is highly sensitive, but its specificity is not as high for detecting malignant lesions. Auxiliary modalities like elastography, Color and Power Doppler ultrasound are used as adjuncts to yield both a high sensitivity and specificity. Superb microvascular imaging (SMI) is a newer modality with more accuracy for detecting breast lesions. In this study, our goal was to investigate the role of SMI as an adjunct to ultrasound and find a suitable combination model for the evaluation of breast masses. METHODS: In this cross-sectional study, 132 women with 172 breast masses who underwent ultrasound-guided biopsy were included.. The ultrasound features of the lesion, the strain ratio in strain elastography, the number of vessels for each lesion, their morphology and distribution in Doppler and Power Doppler ultrasound and SMI were recorded for each lesion. A vascular score and a vascular ratio were defined. RESULTS: In the histologic examination, 31 lesions (18%) were malignant and 141 lesions (82%) were benign. The vascular score was more accurate than the vascular ratio in all three modalities. The predictive ability of strain ratio was higher than Doppler and Power Doppler ultrasound and SMI. Adding SMI alone to ultrasound increased the specificity from 46.10% to 61.2% and the accuracy from 55.80% to 70.11%. In the combination of ultrasound with other modalities, the best was the combination of ultrasound, strain elastography, and SMI; which yielded a specificity and sensitivity of 100% and 74.4%, respectively. CONCLUSION: Adding SMI and STE modalities as adjuncts to ultrasound lowers the chance of missing malignant lesions and reduces unnecessary biopsies of breast lesions. A study with a larger sample size using this combination model to evaluate the accuracy with greater precision is recommended.


Subject(s)
Breast Neoplasms , Elasticity Imaging Techniques , Female , Humans , Cross-Sectional Studies , Sensitivity and Specificity , Ultrasonography/methods , Ultrasonography, Doppler , Elasticity Imaging Techniques/methods , Microvessels/diagnostic imaging , Image-Guided Biopsy , Diagnosis, Differential , Breast Neoplasms/diagnostic imaging
4.
Exp Physiol ; 109(7): 1024-1039, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38590228

ABSTRACT

Transfer function analysis (TFA) is a widely used method for assessing dynamic cerebral autoregulation in humans. In the present study, we assessed the test-retest reliability of established TFA metrics derived from spontaneous blood pressure oscillations and based on 5 min recordings. The TFA-based gain, phase and coherence in the low-frequency range (0.07-0.20 Hz) from 19 healthy volunteers, 37 patients with subarachnoid haemorrhage and 19 patients with sepsis were included. Reliability assessments included the smallest real difference (SRD) and the coefficient of variance for comparing consecutive 5 min recordings, temporally separated 5 min recordings and consecutive recordings with a minimal length of 10 min. In healthy volunteers, temporally separating the 5 min recordings led to a 0.38 (0.01-0.79) cm s-1 mmHg-1 higher SRD for gain (P = 0.032), and extending the duration of recordings did not affect the reliability. In subarachnoid haemorrhage, temporal separation led to a 0.85 (-0.13 to 1.93) cm s-1 mmHg-1 higher SRD (P = 0.047) and a 20 (-2 to 41)% higher coefficient of variance (P = 0.038) for gain, but neither metric was affected by extending the recording duration. In sepsis, temporal separation increased the SRD for phase by 94 (23-160)° (P = 0.006) but was unaffected by extending the recording. A recording duration of 8 min was required to achieve stable gain and normalized gain measures in healthy individuals, and even longer recordings were required in patients. In conclusion, a recording duration of 5 min appears insufficient for obtaining stable and reliable TFA metrics when based on spontaneous blood pressure oscillations, particularly in critically ill patients with subarachnoid haemorrhage and sepsis.


Subject(s)
Blood Pressure , Homeostasis , Subarachnoid Hemorrhage , Humans , Male , Female , Subarachnoid Hemorrhage/physiopathology , Homeostasis/physiology , Blood Pressure/physiology , Adult , Reproducibility of Results , Middle Aged , Cerebrovascular Circulation/physiology , Aged , Sepsis/physiopathology , Young Adult
5.
Am J Obstet Gynecol ; 231(1): 130.e1-130.e10, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38527602

ABSTRACT

BACKGROUND: Assessing the umbilical artery pulsatility index via Doppler measurements plays a crucial role in evaluating fetal growth impairment. OBJECTIVE: This study aimed to investigate perinatal outcomes associated with discordant pulsatility indices of umbilical arteries in fetuses with growth restriction. STUDY DESIGN: In this retrospective cohort study, all singleton pregnancies were included if their estimated fetal weight and/or abdominal circumference fell below the 10th percentile for gestational age (2017-2022). Eligible cases included singleton pregnancies with concurrent sampling of both umbilical arteries within 14 days of birth at the ultrasound evaluation closest to delivery. The exclusion criteria included births before 22 weeks of gestation, evidence of absent or reverse end-diastolic flow in either umbilical artery, and known fetal genetic or structural anomalies. The study compared cases with discordant umbilical artery pulsatility index values (defined as 1 umbilical artery pulsatility index at ≤95th percentile and the other umbilical artery pulsatility index at >95th percentile for gestational age) to pregnancies where both umbilical artery pulsatility indices had normal pulsatility index values and those with both umbilical arteries displaying abnormal pulsatility index values. The primary outcome assessed was the occurrence of composite adverse neonatal outcomes. Multivariable logistic regressions were performed, adjusting for relevant covariates. RESULTS: The study encompassed 1014 patients, including 194 patients (19.1%) with discordant umbilical artery pulsatility index values among those who had both umbilical arteries sampled close to delivery, 671 patients (66.2%) with both umbilical arteries having normal pulsatility index values, and 149 patients (14.7%) with both umbilical arteries exhibiting abnormal values. Pregnancies with discordant umbilical artery pulsatility index values displayed compromised sonographic parameters compared with those with both umbilical arteries showing normal pulsatility index values. Similarly, the number of abnormal umbilical artery pulsatility index values was associated with adverse perinatal outcomes in a dose-response manner. Cases with 1 abnormal (discordant) umbilical artery pulsatility index value showed favorable sonographic parameters and perinatal outcomes compared with cases with both abnormal umbilical artery pulsatility index values, and cases with both abnormal umbilical artery pulsatility index values showed worse sonographic parameters and perinatal outcomes compared with cases with discordant UA PI values. Multivariate analysis revealed that discordant umbilical artery pulsatility indices were significantly and independently associated with composite adverse perinatal outcomes, with an adjusted odds ratio of 1.75 (95% confidence interval, 1.24-2.47; P = .002). CONCLUSION: Evaluating the resistance indices of both umbilical arteries may provide useful data and assist in assessing adverse perinatal outcomes among fetuses with growth restriction.


Subject(s)
Fetal Growth Retardation , Pulsatile Flow , Ultrasonography, Prenatal , Umbilical Arteries , Humans , Female , Umbilical Arteries/diagnostic imaging , Umbilical Arteries/physiopathology , Pregnancy , Fetal Growth Retardation/physiopathology , Fetal Growth Retardation/diagnostic imaging , Retrospective Studies , Adult , Vascular Resistance , Infant, Newborn , Ultrasonography, Doppler , Pregnancy Outcome , Gestational Age , Cohort Studies
6.
Article in English | MEDLINE | ID: mdl-38697934

ABSTRACT

Color pulsed-wave Doppler ultrasound (CPWD-US) emerges as a pivotal tool in intensive care units (ICUs) for diagnosing acute kidney injury (AKI) swiftly and non-invasively. Its bedside accessibility allows for rapid assessments, making it a primary imaging modality for AKI characterization. Furthermore, CPWD-US serves as a guiding instrument for key diagnostic-interventional procedures such as renal needle biopsy and percutaneous nephrostomy, while also facilitating therapy response monitoring and AKI progression tracking. This review shifts focus towards the integration of renal ultrasound into ICU workflows, offering contemporary insights into its utilization through a diagnostic-standard-oriented approach. By presenting a flow chart, this review aims to provide practical guidance on the appropriate use of point-of-care ultrasound (POC-US) in critical care scenarios, enhancing diagnostic precision, patient management, and safety, albeit amidst a backdrop of limited evidence regarding long-term outcomes.

7.
World J Urol ; 42(1): 89, 2024 Feb 20.
Article in English | MEDLINE | ID: mdl-38376590

ABSTRACT

PURPOSE: To investigate the effect of the postural drainage lithotripsy system developed by our experimental team on the vital signs of patient with urinary stones during the stone removal process. METHODS: Four groups of 15 subjects (0°, 10°, 40°, and 70°) were subjected to different angles of head-down tilt to measure middle cerebral artery blood flow velocity (MCAv), cerebrovascular conductance coefficient (CVCi), intracranial pressure (nICP), heart rate (HR), and mean arterial blood pressure (MAP). RESULTS: As the angle of HDT changed, MCAv values, nICP values, CVCi values, HR values, and MAP values changed significantly (all P ≤ 0.001), and the difference was statistically significant. During 10°HDT, despite a slight increase in nICP, the other measurements remained stable. During 40°HDT, only the MCAv values did not change significantly, whereas the rest of the measures were significantly altered. During 70°HDT, all indicators changed significantly. CONCLUSIONS: The significant alterations in cerebral blood flow, intracranial pressure, and hemodynamics induced during the treatment of renal residual fragments with postural drainage should be used with caution in individuals with cerebrovascular accidents. CHINA CLINICAL TRIALS REGISTRY: ChiCTR2300070671; Registration date: 2023-04-18.


Subject(s)
Intracranial Pressure , Lithotripsy , Humans , Blood Pressure , Heart Rate , Drainage, Postural , Cerebrovascular Circulation
8.
Xenotransplantation ; 31(4): e12873, 2024.
Article in English | MEDLINE | ID: mdl-38961605

ABSTRACT

BACKGROUND: Significant progress has been made in kidney xenotransplantation in the past few years, and this field is accelerating towards clinical translation. Therefore, surveillance of the xenograft with appropriate tools is of great importance. Ultrasonography has been widely used in kidney allotransplantation and served as an economical and non-invasive method to monitor the allograft. However, questions remain whether the ultrasonographic criteria established for human kidney allograft could also be applied in xenotransplantation. METHODS: In the current study, we established a porcine-rhesus life sustaining kidney xenotransplantation model. The xenograft underwent intensive surveillance using gray-scale, colorful Doppler ultrasound as well as 2D shear wave elastography. The kidney growth, blood perfusion, and cortical stiffness were measured twice a day. These parameters were compared with the clinical data including urine output, chemistry, and pathological findings. RESULTS: The observation continued for 16 days after transplantation. Decline of urine output and elevated serum creatinine were observed on POD9 and biopsy proven antibody-mediated rejection was seen on the same day. The xenograft underwent substantial growth, with the long axis length increased by 32% and the volume increased by threefold at the end of observation. The resistive index of the xenograft arteries elevated in response to rejection, together with impaired cortical perfusion, while the peak systolic velocity (PSV) was not compromised. The cortical stiffness also increased along with rejection. CONCLUSION: In summary, the ultrasound findings of kidney xenograft shared similarities with those in allograft but possessed some unique features. A modified criteria needs to be established for further application of ultrasound in kidney xenotransplantation.


Subject(s)
Graft Rejection , Heterografts , Kidney Transplantation , Kidney , Macaca mulatta , Transplantation, Heterologous , Animals , Transplantation, Heterologous/methods , Kidney Transplantation/methods , Swine , Kidney/diagnostic imaging , Humans , Ultrasonography/methods
9.
Aging Male ; 27(1): 2339352, 2024 Dec.
Article in English | MEDLINE | ID: mdl-38590113

ABSTRACT

OBJECTIVES: To evaluate the efficacy of a novel approach to achieve the optimal penile erection during the penile doppler ultrasound (PDU) examination, which was oral sildenafil combined alprostadil injection. MATERIALS AND METHODS: A total of 60 ED patients were enrolled in our prospective study, and they were randomly assigned to two group with different PDU order. The approaches assisted the PDU included two models, mode A meaning injection of 15 µg alprostadil and model B meaning oral sildenafil 100 mg plus injection of 15 µg alprostadil. The PDU parameters were measured continuously before induced erection, and 5, 10, 15, 20, 25 min. RESULTS: Each group included 30 ED patients with similar clinical characteristics. After pooling the results together, the PSV, EDV, and RI were all improved significantly, when adding the oral sildenafil administration to assist PDU. Also, the clinical response of oral sildenafil administration plus alprostadil injection was better than that in alprostadil injection alone (p = 0.016). The arterial ED were decreased from 31.67% to 15.00% with the P value 0.031, and the mixed ED was also decreased statistically (23.33% vs 8.33%, p = 0.024). CONCLUSION: Oral sildenafil administration plus alprostadil injection could improve the diagnostic accuracy of PDU.


Subject(s)
Erectile Dysfunction , Penile Erection , Male , Humans , Sildenafil Citrate/pharmacology , Penile Erection/physiology , Alprostadil , Erectile Dysfunction/drug therapy , Erectile Dysfunction/diagnosis , Prospective Studies , Penis/diagnostic imaging , Ultrasonography, Doppler
10.
Vasc Med ; 29(2): 153-162, 2024 04.
Article in English | MEDLINE | ID: mdl-38469710

ABSTRACT

INTRODUCTION: Maximal acceleration time of distal arteries of the foot (ATmax) is correlated to ankle-brachial index (ABI) and toe-brachial index (TBI), and seems very promising in diagnosing severe peripheral artery disease (PAD) and especially critical limb-threatening ischemia (CLTI). Our goal was to confirm the cut-off value of 215 ms to predict a toe pressure (TP) ⩽ 30 mmHg. METHODS: A 4-month retrospective study was conducted on patients addressed for suspicion of PAD. Demographic data, ABI, TBI, and Doppler ultrasound scanning parameters of the dorsal pedis and lateral plantar arteries (DPA and LPA) were recorded. RESULTS: A total of 137 patients with 258 lower limbs were included. ATmax was highly correlated to TBI (r = -0.89, p < 0.001). With the cut-off value of 215 ms, ATmax was effective to diagnose TP ⩽ 30 mmHg with a sensitivity of 93% [95% CI 77-99], a specificity of 96% [95% CI 92-98], a positive predictive value of 73% [95% CI 56-86], a negative predictive value of 99% [95% CI 97-100], and an area under the receiver operating characteristics curve of 0.99 [95% CI 0.98-1.00]. ATmax also showed promising results to rule out PAD in healthy patients. CONCLUSION: ATmax is a reliable diagnostic tool to diagnose low TP and could be a new easily performed hemodynamic criterion for diagnosis of CLTI.


Subject(s)
Ankle Brachial Index , Peripheral Arterial Disease , Humans , Retrospective Studies , Peripheral Arterial Disease/diagnostic imaging , Arteries , Chronic Limb-Threatening Ischemia , Predictive Value of Tests , Acceleration
11.
BJOG ; 131(4): 472-482, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37718558

ABSTRACT

OBJECTIVES: To investigate the association and the potential value of prelabour fetal heart rate short-term variability (STV) determined by computerised cardiotocography (cCTG) and maternal and fetal Doppler in predicting labour outcomes. DESIGN: Prospective cohort study. SETTING: The Prince of Wales Hospital, a tertiary maternity unit, in Hong Kong SAR. POPULATION: Women with a term singleton pregnancy in latent phase of labour or before labour induction were recruited during May 2019-November 2021. METHODS: Prelabour ultrasonographic assessment of fetal growth, Doppler velocimetry and prelabour cCTG monitoring including Dawes-Redman CTG analysis were registered shortly before induction of labour or during the latent phase of spontaneous labour. MAIN OUTCOME MEASURES: Umbilical cord arterial pH, emergency delivery due to pathological CTG during labour and neonatal intensive care unit (NICU)/special care baby unit (SCBU) admission. RESULTS: Of the 470 pregnant women invited to participate in the study, 440 women provided informed consent and a total of 400 participants were included for further analysis. Thirty-four (8.5%) participants underwent emergency delivery for pathological CTG during labour. A total of 6 (1.50%) and 148 (37.00%) newborns required NICU and SCBU admission, respectively. Middle cerebral artery pulsatility index (MCA-PI) and MCA-PI z-score were significantly lower in pregnancies that required emergency delivery for pathological CTG during labour compared with those that did not (1.23 [1.07-1.40] versus 1.40 [1.22-1.64], p = 0.002; and 0.55 ± 1.07 vs. 0.12 ± 1.06), p = 0.049]. This study demonstrated a weakly positive correlation between umbilical cord arterial pH and prelabour log10 STV (r = 0.107, p = 0.035) and the regression analyses revealed that the contributing factors for umbilical cord arterial pH were smoking (p = 0.006) and prelabour log10 STV (p = 0.025). CONCLUSIONS: In pregnant women admitted in latent phase of labour or for induction of labour at term, prelabour cCTG STV had a weakly positive association with umbilical cord arterial pH but was not predictive of emergency delivery due to pathological CTG during labour.


Subject(s)
Cardiotocography , Labor, Obstetric , Pregnancy , Female , Infant, Newborn , Humans , Prospective Studies , Fetus , Prenatal Care
12.
Brain Cogn ; 179: 106182, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38824809

ABSTRACT

A single bout of exercise improves executive function (EF) and is a benefit - in part -attributed to an exercise-mediated increase in cerebral blood flow enhancing neural efficiency. Limited work has used an event-related protocol to examine postexercise changes in preparatory phase cerebral hemodynamics for an EF task. This is salient given the neural efficiency hypothesis' assertion that improved EF is related to decreased brain activity. Here, event-related transcranial Doppler ultrasound was used to measure pro- (saccade to target) and antisaccades (saccade mirror-symmetrical target) preparatory phase middle cerebral artery velocity (MCAv) prior to and immediately after 15-min of aerobic exercise. Antisaccades produced longer reaction times (RT) and an increased preparatory phase MCAv than prosaccades - a result attributed to greater EF neural activity for antisaccades. Antisaccades selectively produced a postexercise RT reduction (ps < 0.01); however, antisaccade preparatory phase MCAv did not vary from pre- to postexercise (p=0.53) and did not correlate with the antisaccade RT benefit (p = 0.31). Accordingly, results provide no evidence that improved neural efficiency indexed via functional hyperemia is linked to a postexercise EF behavioural benefit. Instead, results support an evolving view that an EF benefit represents the additive interplay between interdependent exercise-mediated neurophysiological changes.


Subject(s)
Cerebrovascular Circulation , Executive Function , Exercise , Saccades , Ultrasonography, Doppler, Transcranial , Humans , Saccades/physiology , Exercise/physiology , Male , Female , Young Adult , Adult , Cerebrovascular Circulation/physiology , Ultrasonography, Doppler, Transcranial/methods , Executive Function/physiology , Reaction Time/physiology , Hemodynamics/physiology , Inhibition, Psychological , Middle Cerebral Artery/physiology , Psychomotor Performance/physiology
13.
Pediatr Nephrol ; 39(7): 2235-2243, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38416215

ABSTRACT

BACKGROUND: Acute kidney injury (AKI) is a common condition in critically ill children and is associated with increased morbidity and mortality. This study aimed to assess the performance of point-of-care ultrasonography to predict AKI in children undergoing cardiac surgery. METHODS: In this prospective study, consecutive children underwent kidney Doppler ultrasound examination within 24 h following cardiac surgery, and an experienced operator obtained both renal resistive index (RRI) and renal pulsatility index (RPI). AKI was defined by the Kidney Disease Improving Global Outcome (KDIGO) criteria. The primary outcome was the diagnosis of severe AKI (KDIGO stage 2 or 3) on day 3. RESULTS: A total of 58 patients were included. Median age and weight were 12.9 months (IQR 6.0-37.9) and 7.36 kg (IQR 5.19-11.40), respectively. On day 3, 13 patients were classified as having AKI, of which 11 were severe. RRI could effectively predict AKI (area under the ROC curve [AUC] 0.83, 95% CI 0.71-0.92; p < 0.001) as well as RPI (AUC 0.81, 95% CI 0.69-0.90; p < 0.001). The optimal cutoff value for RRI was 0.85 (sensitivity, 73%; specificity, 83%; positive predictive value [PPV], 50%; and negative predictive value [NPV], 93%), while for RPI was 1.95 (sensitivity, 73%; specificity, 78%; PPV, 44%; and NPV, 92%). Similar results were found in the analysis for prediction on day 5. Significant correlations were found between Doppler-based variables and estimated GFR and furosemide dose on day 3. CONCLUSIONS: Kidney Doppler ultrasound may be a promising tool for predicting AKI in children undergoing cardiac surgery.


Subject(s)
Acute Kidney Injury , Cardiac Surgical Procedures , Predictive Value of Tests , Ultrasonography, Doppler , Humans , Acute Kidney Injury/etiology , Acute Kidney Injury/diagnosis , Acute Kidney Injury/diagnostic imaging , Male , Female , Infant , Prospective Studies , Ultrasonography, Doppler/methods , Cardiac Surgical Procedures/adverse effects , Child, Preschool , Kidney/diagnostic imaging , Kidney/blood supply , Kidney/physiopathology , Renal Artery/diagnostic imaging , Postoperative Complications/etiology , Postoperative Complications/diagnosis , Postoperative Complications/epidemiology , Postoperative Complications/diagnostic imaging , Pulsatile Flow
14.
Eur J Pediatr ; 2024 May 25.
Article in English | MEDLINE | ID: mdl-38795136

ABSTRACT

Preterm neonates are at risk for neurodevelopmental impairment, especially those with intraventricular hemorrhage (IVH). Cerebral vasospasm (VSP) is a common complication after subarachnoid hemorrhage (SAH) in adult population, but it is unknown if preterm neonates with IVH may develop it. We prospectively enrolled premature newborns < 32 weeks with IVH and without IVH. All patients received serial transcranial sonography through the temporal window of the middle cerebral artery, anterior cerebral artery, posterior cerebral artery, and the internal carotid artery with transcranial Doppler sonography days 2, 4, and 10 of life. Cerebral blood velocities (CBFVs) were measured including median velocity flow (MV), peak systolic velocity (PSV), and maximum end-diastolic velocity (EDV). Resistance index and pulsatility index were calculated. VSP was defined as an increase of 50% in the baseline velocity per day and/or a Lindegaard ratio higher than 3. Fifty subjects were enrolled. None of the patients with IVH showed elevation of MV or a Lindegaard ratio > 3. There were no differences between IVH and without IVH groups regarding resistance index and pulsatility index.    Conclusion: Preterm infants with IVH do not present a pattern of VSP analyzed by Doppler transcranial ultrasound in this pilot study. What is Known: • In adult population with subarachnoid hemorrhage the most treatable cause of cerebral ischemia is due cerebral vasospasm but is unknown if premature newborn may have vasospasm due the extravasation of blood in the context of intraventricular hemorrhage What is New: •In this pilot study we did not find in premature newborn with intraventricular hemorrhage signs of vasoespam measured by transcranial color doppler ultrasound.

15.
Endocr Pract ; 30(5): 465-469, 2024 May.
Article in English | MEDLINE | ID: mdl-38331386

ABSTRACT

OBJECTIVE: To assess the bedside utility of Spectral Doppler Ultrasound (SDUS) in the initial evaluation of patients presenting with thyrotoxicosis. METHODS: This is a retrospective cross-sectional study of patients diagnosed with thyrotoxicosis at an academic outpatient endocrinology clinic from August 2019 to November 2022. The thyroid arteries' peak systolic velocities (PSV) were measured bilaterally using SDUS. PSV ≥40 cm/s in at least a single thyroid artery was considered a reasonable cut-off for Graves' disease and PSV of perinodular artery ≥ 25 cm/s for toxic adenoma. RESULTS: We identified 73 patients. Mean age ± standard deviation 45.2 ± 16.4 years, 54 (74.0%) were female, 49 (67.1%) were Caucasian, 23 (31.5%) were African American, and 1 (1.4%) was Asian. The confirmed diagnoses were 48 (65.8%) Graves' disease, 13 (17.8%) thyroiditis, four (5.5%) toxic adenoma, four (5.5%) amiodarone-induced thyroiditis type 2, 1 (1.4%) toxic multinodular goiter, 1 (1.4%) had an unremarkable repeat thyroid function testing, and two (2.7%) were unconfirmed. Diagnosis based on the SDUS initial assessment was accurate in 65 (89.0%) of the patients, and it was conclusive and confirmatory during the initial encounter in 55 (75.3%) of the patients before additional testing. A thyroid scan was obtained in nine (12.3%) patients. Incorrectly diagnosed patients were observed in two patients of each of the following categories: Graves' disease, thyroiditis, toxic adenoma, and unconfirmed diagnoses. CONCLUSIONS: SDUS can be a valuable, efficient, and cost-effective bedside tool in the initial assessment of patients presenting with thyrotoxicosis.


Subject(s)
Thyroid Gland , Thyrotoxicosis , Humans , Female , Thyrotoxicosis/diagnostic imaging , Cross-Sectional Studies , Male , Retrospective Studies , Middle Aged , Adult , Thyroid Gland/diagnostic imaging , Graves Disease/diagnostic imaging , Ultrasonography, Doppler , Point-of-Care Testing
16.
Acta Obstet Gynecol Scand ; 103(5): 980-991, 2024 May.
Article in English | MEDLINE | ID: mdl-38229258

ABSTRACT

INTRODUCTION: In clinical practice, fetal heart rate monitoring is performed intermittently using Doppler ultrasound, typically for 30 minutes. In case of a non-reassuring heart rate pattern, monitoring is usually prolonged. Noninvasive fetal electrocardiography may be more suitable for prolonged monitoring due to improved patient comfort and signal quality. This study evaluates the performance and patient experience of four noninvasive electrocardiography devices to assess candidate devices for prolonged noninvasive fetal heart rate monitoring. MATERIAL AND METHODS: Non-critically sick women with a singleton pregnancy from 24 weeks of gestation were eligible for inclusion. Fetal heart rate monitoring was performed during standard care with a Doppler ultrasound device (Philips Avalon-FM30) alone or with this Doppler ultrasound device simultaneously with one of four noninvasive electrocardiography devices (Nemo Fetal Monitoring System, Philips Avalon-Beltless, Demcon Dipha-16 and Dräger Infinity-M300). Performance was evaluated by: success rate, positive percent agreement, bias, 95% limits of agreement, regression line, root mean square error and visual agreement using FIGO guidelines. Patient experience was captured using a self-made questionnaire. RESULTS: A total of 10 women were included per device. For fetal heart rate, Nemo performed best (success rate: 99.4%, positive percent agreement: 94.2%, root mean square error 5.1 BPM, bias: 0.5 BPM, 95% limits of agreement: -9.7 - 10.7 BPM, regression line: y = -0.1x + 11.1) and the cardiotocography tracings obtained simultaneously by Nemo and Avalon-FM30 received the same FIGO classification. Comparable results were found with the Avalon-Beltless from 36 weeks of gestation, whereas the Dipha-16 and Infinity-M300 performed significantly worse. The Avalon-Beltless, Nemo and Infinity-M300 closely matched the performance of the Avalon-FM30 for maternal heart rate, whereas the performance of the Dipha-16 deviated more. Patient experience scores were higher for the noninvasive electrocardiography devices. CONCLUSIONS: Both Nemo and Avalon-Beltless are suitable devices for (prolonged) noninvasive fetal heart rate monitoring, taking their intended use into account. But outside its intended use limit of 36 weeks' gestation, the Avalon-Beltless performs less well, comparable to the Dipha-16 and Infinity-M300, making them currently unsuitable for (prolonged) noninvasive fetal heart rate monitoring. Noninvasive electrocardiography devices appear to be preferred due to greater comfort and mobility.


Subject(s)
Cardiotocography , Heart Rate Determination , Pregnancy , Female , Humans , Cardiotocography/methods , Fetal Monitoring/methods , Electrocardiography , Heart Rate, Fetal/physiology , Patient Outcome Assessment
17.
Acta Obstet Gynecol Scand ; 103(5): 938-945, 2024 May.
Article in English | MEDLINE | ID: mdl-38240293

ABSTRACT

INTRODUCTION: The inaccuracy of late pregnancy dating is often discussed, and the impact on diagnosis of fetal growth restriction is a concern. However, the magnitude and direction of this effect has not previously been demonstrated. In this study, we aimed to investigate the effect of late pregnancy dating by head circumference on the detection of late onset growth restriction, compared to first trimester crown-rump length dating. MATERIAL AND METHODS: This was a cohort study of 14 013 pregnancies receiving obstetric care at a tertiary center over a three-year period. Universal scans were performed at 12 weeks, including crown-rump length; at 20 weeks including fetal biometry; and at 36 weeks, where biometry, umbilical artery doppler and cerebroplacental ratio were used to determine the incidence of fetal growth restriction according to the Delphi consensus. For the entire cohort, the gestational age was first calculated using T1 dating; and was then recalculated using head circumference at 20 weeks (T2 dating); and at 36 weeks (T3 dating). The incidence of fetal growth restriction following T2 and T3 dating was compared to T1 dating using four-by-four sensitivity tables. RESULTS: When the cohort was redated from T1 to T2, the median gestation at delivery changed from 40 + 0 to 40 + 2 weeks (p < 0.001). When the cohort was redated from T1 to T3, the median gestation at delivery changed from 40 + 0 to 40 + 3 weeks (p < 0.001). T2 dating resulted in fetal growth restriction sensitivity of 80.2% with positive predictive value of 78.8% compared to T1 dating. T3 dating resulted in sensitivity of 8.6% and positive predictive value of 27.7%, respectively. The sensitivity of abnormal CPR remained high despite T2 and T3 redating; 98.0% and 89.4%, respectively. CONCLUSIONS: Although dating at 11-14 weeks is recommended, late pregnancy dating is sometimes inevitable, and this can prolong the estimated due date by an average of two to three days. One in five pregnancies which would be classified as growth restricted if the pregnancy was dated in the first trimester, will be reclassified as nongrowth restricted following dating at 20 weeks, whereas nine out of 10 pregnancies will be reclassified as non-growth restricted with 36-week dating.


Subject(s)
Fetal Growth Retardation , Infant, Small for Gestational Age , Female , Pregnancy , Humans , Infant, Newborn , Fetal Growth Retardation/diagnosis , Cohort Studies , Gestational Age , Prenatal Care , Ultrasonography, Prenatal
18.
Ann Vasc Surg ; 2024 Jul 13.
Article in English | MEDLINE | ID: mdl-39009121

ABSTRACT

OBJECTIVES: The value of Color Doppler Ultrasound (CDU) for perioperative evaluation and follow-up outcomes of carotid body tumor (CBT) remains elusive. This study aimed to investigate the role of CDU in CBT in our center. METHODS: From January 2015 to December 2020, 75 patients with CBT were included in the study. Computed Tomography Angiography (CTA) and CDU data of patients were collected and analyzed. The postoperative recovery and follow-up outcomes were summarized. RESULTS: A total of 91 CBTs in 75 patients were included in the study. 73.3% of patients had unilateral lesions, while 26.7% had bilateral lesions. Lesions were categorized as Shamblin I (4.4%), Shamblin II (52.7%), and Shamblin III (42.9%). 79.5% lesions were treated by surgical resection, 12.3% were treated by surgical resection with internal carotid artery reconstructed by artificial vessel, while 8.2% were treated by surgical resection with internal carotid artery reconstructed by autogenous great saphenous vein. Compared with CTA, the sensitivity of CDU for detection of CBT was 96.7%, the sensitivity and specificity of CDU for detection of Shamblin Ⅰ lesions were both 100%, the sensitivity and specificity for Shamblin Ⅱ were 100% and 72.1%, respectively, while the sensitivity and specificity for Shamblin Ⅲ were 69.2% and 100%, respectively. There were no statistically significant differences between CTA and CDU for detection of the maximal diameter, volume of CBT and distance between the end of the tumor and the mastoid process. 79.7% of patients were followed up with CDU. Recurrence of CBT occurred in 1 patient. CDU showed that stenosis and occlusion of artificial vessel occurred in 1 and 6 patients, respectively. Occlusion of autogenous great saphenous vein was found in 2 cases. CONCLUSIONS: CDU can accurately diagnose Shamblin Ⅰ CBT, have high sensitivity for Shamblin Ⅱ and high specificity for Shamblin Ⅲ CBT. It plays an important role in diagnosis, perioperative evaluation and follow-up analysis of CBT.

19.
BMC Med Imaging ; 24(1): 10, 2024 01 03.
Article in English | MEDLINE | ID: mdl-38172706

ABSTRACT

BACKGROUND: Computed tomography angiography (CTA) and magnetic resonance angiography (MRA) provide accurate vascular imaging information, but their use may be contraindicated. Color Doppler ultrasonography (CDU) provides simple, safe, noninvasive, and reproducible imaging. We therefore investigated the role of preoperative CDU combined with CTA and MRA in the quantification, typing, and diagnosis of carotid body tumors (CBTs). METHODS: We retrospectively analyzed patients with CBTs categorized into group A (type I [n = 1] and type II [n = 10]) or group B (type III [n = 56]) per the intraoperative Shamblin classification. CDU, CTA, and MRA characteristics of CBTs were observed, surgical results were correlated, and the diagnostic threshold of the CBT classification was calculated. RESULTS: CBTs were usually located at the common carotid artery bifurcation, encircling the carotid artery. An increased angle was found between the internal and external carotid arteries. On CDU, CBTs primarily presented as homogeneous hypoechoic masses with clear boundaries, rich flow signals, and a high-speed, low-resistance artery-like flow spectrum. CTA showed uniform or heterogeneous marked enhancement. MRA showed mixed T1 and slightly longer T2 signals and uniform or uneven obvious enhancement. With increases in the lesion size, amount of blood transfused, and operation time, the intraoperative classification level and possibility of skull-base invasion increased. When the maximum diameter of the lesion, the volume of the tumor, the distance between the upper margin of the tumor to the mastoid and the mandibular angle were 3.10 cm, 10.15 cm3, - 3.26 cm, and 0.57 cm, respectively, the largest Youden index was the best diagnostic boundary value for Shamblin type III tumors. CONCLUSIONS: CDU combined with CTA and MRA can accurately evaluate the size and classification of CBTs.


Subject(s)
Carotid Body Tumor , Computed Tomography Angiography , Humans , Computed Tomography Angiography/methods , Magnetic Resonance Angiography , Retrospective Studies , Carotid Body Tumor/pathology , Carotid Body Tumor/surgery , Ultrasonography, Doppler, Color/methods
20.
BMC Anesthesiol ; 24(1): 66, 2024 Feb 20.
Article in English | MEDLINE | ID: mdl-38378447

ABSTRACT

BACKGROUND: Esketamine is increasingly used in clinical anesthesia. The effect of esketamine on the blood flow velocity of the middle cerebral artery has a clinical guiding effect. To investigate the effect of esketamine combined with propofol-induced general anesthesia for endotracheal intubation on the blood flow velocity of middle cerebral artery and hemodynamics during the induction period. METHODS: The randomized clinical trial included 80 patients aged 20-65 years who would undergo non-intracranial elective surgery under general anesthesia in our hospital from May 2022 to May 2023. The participants were divided into two groups based on anesthesia drugs: sufentanil 0.5µg/kg (group C) or 1.5mg/kg esketamine (group E). The primary outcome was variation value in average cerebral blood velocity. The secondary outcomes included cerebral blood flow velocities (CBFV), blood pressure (BP) and heart rate (HR) at four different time points: before induction of general anesthesia (T0), 1 min after the induction drug injected (T1), before endotracheal intubation (T2), and 1min after endotracheal intubation (T3). The occurrence of hypotension, hypertension, tearing and choking during induction was also documented. RESULTS: The variation of average CBFV from time T0 to T2(ΔVm1) and the variation from time T3 to T0 (ΔVm2) were not obviously different. The median consumption of intraoperative sufentanil in group C was obviously lower than that in group E. At T1, the mean HR of group E was significantly higher than that of group C. At T2 and T3, the BP and HR of group E were obviously higher than that of group C. At T2, the CBFV in the group E were obviously higher than those in the group C. The incidence of hypotension was significantly reduced in the group E compared with the group C. There were no differences in the other outcomes. CONCLUSIONS: The induction of esketamine combined with propofol does not increase the blood flow velocity of middle cerebral artery. Esketamine is advantageous in maintaining hemodynamic stability during induction. Furthermore, the administration of esketamine did not result in an increased incidence of adverse effects. TRIAL REGISTRATION: 15/06/2023 clinicaltrials.gov ChiCTR2300072518 https://www.chictr.org.cn/bin/project/edit?pid=176675 .


Subject(s)
Ketamine , Propofol , Humans , Anesthesia, General , Cerebrovascular Circulation , Hypotension , Ketamine/pharmacology , Propofol/pharmacology , Sufentanil/pharmacology , Young Adult , Adult , Middle Aged , Aged
SELECTION OF CITATIONS
SEARCH DETAIL