Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Ann Rheum Dis ; 2022 Jun 13.
Article in English | MEDLINE | ID: mdl-35697487

ABSTRACT

INTRODUCTION: Commercial assays measuring antibodies to citrullinated protein/peptide (ACPA) show poor quantitative agreement. The diagnostic industry has never adopted the International Union of Immunological Societies-Centers for Disease Control and Prevention (IUIS-CDC) ACPA reference standard. Recently, the National Institute for Biological Standards and Control (NIBSC) prepared a new candidate ACPA standard (18/204). We evaluated both reference materials using different commercially available ACPA assays. MATERIALS AND METHODS: This is an international study in which the NIBSC candidate ACPA standard and the IUIS-CDC ACPA reference material were analysed together with 398 diagnostic samples from individuals with rheumatoid arthritis (RA) and in 1073 individuals who did not have RA using nine commercial ACPA assays. RESULTS: For both reference materials and samples from individuals with RA and individuals who did not have RA, there were large differences in quantitative ACPA results between assays. For most assays, values for the IUIS-CDC standard were lower than values for NIBSC 18/204 and the IUIS-CDC/NIBSC ratio was comparable for several, but not all assays. When NIBSC 18/204 was used as a calibrator, an improvement in alignment of ACPA results across several of the evaluated assays was obtained. Moreover, NIBSC 18/204 could align clinical interpretation for some but not all assays. CONCLUSION: Adoption of an international standard for ACPA determination is highly desirable. The candidate NIBSC 18/204 standard improved the standardisation and alignment of most ACPA assays and might therefore be recommended to be used as reference in commercial assays.

2.
Biologicals ; 42(1): 57-64, 2014 Jan.
Article in English | MEDLINE | ID: mdl-24325871

ABSTRACT

Recent reports of severe haemolytic reactions upon high dose treatment with new generation intravenous immunoglobulins (IVIGs) prompted us to examine the anti-A and anti-B haemagglutinin content of these therapeutics. We compared four different test methods, namely the indirect and direct haemagglutination test as described in the European Pharmacopoiea (Ph. Eur.) and two commercial gelcard systems with the aim to define the most reliable method for a large-scale comparison of different IVIG products. Absolute titres varied when the same samples were analyzed by the four methods, while the relative ranking of six different IVIG preparations representing different manufacturing classes was identical. New generation IVIGs showed 1-2 titre steps higher anti-A titres than the older products. Haemagglutinin titres of all 48 IVIG batches analyzed were within the current Ph. Eur. specification of ≤1:64 when tested by the official pharmacopoeial method. Based on efficiency, reliability and lower costs, the direct gelcard method could be a valid alternative to the official Ph. Eur. method to serve as a limit test. However, due to the highest intermediate precision, the official Ph. Eur. method seems to be most suitable to compare haemagglutinin titres of different IVIG products.


Subject(s)
Hemagglutinins/analysis , Immunoglobulins, Intravenous/analysis , Humans , Reproducibility of Results
3.
Diagn Microbiol Infect Dis ; 109(2): 116238, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38554539

ABSTRACT

The interpretation for Zika virus serology results is challenging due to high antibody cross reactivity with other flaviviruses. This limits availability of reliable and accurate methods for serosurveillance studies to understand the disease burden. Therefore, we conducted study to harmonize anti-Zika IgG antibody detection assays with 1st WHO International Standard (16/352) and working standard (16/320) for anti-Zika virus antibody.Additionally, evaluated NuGenTMZIKA-IgG and NovaLisa®ZIKA virus IgG-Capture ELISA using a panel of 278 seraFurther, 106 samples positive for other-flavi viruses were taken for assessing cross-reactivity of the assay, all serums were further tested by Zika-PRNT. The results of this study indicates satisfactory performance of both the assays. Serological and neutralization assays were calibrated according to the international standards. This will help in understanding antibody dynamics in serosurveillance and vaccine studies. However the performance of the kits with possibilities of cross-reactivity will have to be verified by coupling ZIKV and DENV specific ELISA.


Subject(s)
Antibodies, Viral , Cross Reactions , Enzyme-Linked Immunosorbent Assay , Immunoglobulin G , Zika Virus Infection , Zika Virus , Enzyme-Linked Immunosorbent Assay/methods , Enzyme-Linked Immunosorbent Assay/standards , Zika Virus/immunology , Immunoglobulin G/blood , Humans , Antibodies, Viral/blood , Zika Virus Infection/diagnosis , Zika Virus Infection/immunology , Zika Virus Infection/blood , Reagent Kits, Diagnostic/standards , Serologic Tests/standards , Serologic Tests/methods , Sensitivity and Specificity , Female , Adult , Adolescent , Young Adult
4.
Methods Mol Biol ; 2779: 259-271, 2024.
Article in English | MEDLINE | ID: mdl-38526789

ABSTRACT

COVID-19 is a global pandemic caused by the highly infectious SARS-CoV-2 virus. Efforts to combat SARS-CoV-2 infection include mass vaccination and development of monoclonal and convalescent plasma therapeutics that require precise measurements of correlative, functional neutralizing antibodies that prevent virus infection. Developing rapid, safe, easy-to-use, and high-quality neutralization assays are essential for the success of the massive effort. Here, we developed a vesicular stomatitis virus-based neutralization assay that was capable of quantifying varying degrees of neutralization in patient serum samples. This assay has two detection readouts, flow cytometry and live cell imaging. The two readout methods produced consistent values of all 50% neutralization titers, further enhancing measurement confidence on the assay. Moreover, the use of available reference standards such as the World Health Organization International Standard (NIBSC code 20/136) enables quantification and standardization of the pseudovirus neutralization assay with neutralizing antibody titers measured in International Units/mL. Quantitative and standardized neutralization assays are critical for reliable efficacy evaluation and comparison of numerous vaccines and therapeutics.


Subject(s)
COVID-19 , Humans , SARS-CoV-2 , COVID-19 Serotherapy , Immunologic Tests , Flow Cytometry , Antibodies, Neutralizing , Antibodies, Viral , Neutralization Tests , Spike Glycoprotein, Coronavirus
5.
Diagnosis (Berl) ; 9(2): 274-279, 2021 12 02.
Article in English | MEDLINE | ID: mdl-34851563

ABSTRACT

OBJECTIVES: A few CLIA automated immunoassays for the recognition of anti S1-RBD SARS-CoV-2 antibodies have recently been placed on the market. Preliminary data demonstrate a high correlation between methods but wide differences in absolute concentrations. A new WHO international standard for anti-SARS-CoV-2 immunoglobulin, NIBSC code 20/136, has been recently introduced to reduce the differences. The aim of this study is thus to verify the harmonization made by NIBSC 20/136 on Ab anti S1-RBD measurement on real samples. METHODS: The following assays were studied: LIAISON® SARS-CoV-2 TrimericS IgG (DiaSorin); Elecsys® anti-SARS-CoV-2 S (ROCHE); Atellica IM SARS-CoV-2 IgG (sCOVG) (Siemens); MAGLUMI® SARS-CoV-2 S-RBD IgG (Snibe), measuring 210 samples from 70 health workers with no previous SARS-CoV2 infection, during their Pfizer-BioNTech's BNT162b2 vaccination period. RESULTS: The recalculation of concentrations based on the NIBSC 20/136 standardization improve the analytical and diagnostic comparability but do not cancel this variability between methods: recalibrated results remain different across methods, both in terms of tendency and single data. CONCLUSIONS: The recalculation of concentrations based on the NIBSC 20/136 standardization improves the analytical and diagnostic comparability but does not cancel the differences between methods: recalibrated results remain different across methods, both in terms of tendency and single data.


Subject(s)
COVID-19 , SARS-CoV-2 , Antibodies, Viral , BNT162 Vaccine , COVID-19/diagnosis , Humans , Immunoglobulin G , RNA, Viral , Reference Standards , World Health Organization
6.
Hum Vaccin Immunother ; 10(9): 2691-6, 2014.
Article in English | MEDLINE | ID: mdl-25483504

ABSTRACT

Introduction of Haemophilus influenzae type b (Hib) vaccine in low- and middle-income countries has been limited by cost and availability of Hib conjugate vaccines for a long time. It was previously recognized by the Institute for Translational Vaccinology (Intravacc, originating from the former Vaccinology Unit of the National Institute of Public Health [RIVM] and the Netherlands Vaccine Institute [NVI]) that local production of a Hib conjugate vaccine would increase the affordability and sustainability of the vaccine and thereby help to speed up Hib introduction in these countries. A new affordable and a non-infringing production process for a Hib conjugate vaccine was developed, including relevant quality control tests, and the technology was transferred to a number of vaccine manufacturers in India, Indonesia, and China. As part of the Hib technology transfer project managed by Intravacc, a preclinical toxicity study was conducted in the Netherlands to test the safety and immunogenicity of this new Hib conjugate vaccine. The data generated by this study were used by the technology transfer partners to accelerate the clinical development of the new Hib conjugate vaccine. A repeated dose toxicity and local tolerance study in rats was performed to assess the reactogenicity and immunogenicity of a new Hib conjugate vaccine compared to a licensed vaccine. The results showed that the vaccine was well tolerated and immunogenic in rats, no major differences in both safety and immunogenicity in rats were found between the vaccine produced according to the production process developed by Intravacc and the licensed one. Rats may be useful to verify the immunogenicity of Hib conjugate vaccines and for preclinical evaluation. In general, nonclinical evaluation of the new Hib conjugate vaccine, including this proof of concept (safety and immunogenicity study in rats), made it possible for technology transfer partners, having implemented the original process with no changes in the manufacturing process and vaccine formulation, to start directly with phase 1 clinical trials.


Subject(s)
Drug Evaluation, Preclinical , Haemophilus Infections/prevention & control , Haemophilus Vaccines/adverse effects , Haemophilus Vaccines/immunology , Haemophilus influenzae type b/immunology , Technology Transfer , Animals , China , Haemophilus Infections/microbiology , Haemophilus Vaccines/administration & dosage , India , Indonesia , Netherlands , Rats, Wistar , Vaccines, Conjugate/administration & dosage , Vaccines, Conjugate/adverse effects , Vaccines, Conjugate/immunology
7.
Hum Vaccin Immunother ; 10(9): 2697-703, 2014.
Article in English | MEDLINE | ID: mdl-25483494

ABSTRACT

Quality control of Hemophilus Influenzae type b (Hib) conjugate vaccines is mainly dependent on physicochemical methods. Overcoming sample matrix interference when using physicochemical tests is very challenging, these tests are therefore only used to test purified samples of polysaccharide, protein, bulk conjugate, and final product. For successful development of a Hib conjugate vaccine, several ELISA (enzyme-linked immunosorbent assay) methods were needed as an additional tool to enable testing of in process (IP) samples. In this paper, three of the ELISA's that have been very valuable during the process development, implementation and scaling up are highlighted. The PRP-ELISA, was a very efficient tool in testing in process (IP) samples generated during the development of the cultivation and purification process of the Hib-polysaccharide. The antigenicity ELISA, was used to confirm the covalent linkage of PRP and TTd in the conjugate. The anti-PRP IgG ELISA was developed as part of the immunogenicity test, used to demonstrate the ability of the Hib conjugate vaccine to elicit a T-cell dependent immune response in mice. ELISA methods are relatively cheap and easy to implement and therefore very useful during the development of polysaccharide conjugate vaccines.


Subject(s)
Haemophilus Vaccines/immunology , Quality Control , Technology Transfer , Technology, Pharmaceutical/methods , Animals , Enzyme-Linked Immunosorbent Assay/methods , Haemophilus Infections/microbiology , Haemophilus Infections/prevention & control , Haemophilus Vaccines/administration & dosage , Haemophilus Vaccines/isolation & purification , Haemophilus influenzae type b/immunology , Mice , T-Lymphocytes/immunology , Vaccines, Conjugate/administration & dosage , Vaccines, Conjugate/immunology , Vaccines, Conjugate/isolation & purification
8.
J Clin Virol ; 58(1): 221-6, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23809476

ABSTRACT

BACKGROUND: The Elecsys® HIV combi PT assay was developed to allow earlier detection of HIV infection with increased sensitivity and specificity. OBJECTIVES: To validate the assay for screening and reliable early detection of HIV-1 infection in Asia. STUDY DESIGN: Samples tested reflected those routinely screened in Asia and comprised: HIV-1 antigen lysate (25 samples) and antibody (20 samples) dilutions; seven HIV-1 seroconversion panels (46 samples); 39 patient samples from early infection; 183 known-positive sera; HIV-1 p24 antigen sensitivity panel (seven samples); >500 routine clinical samples per center. The Elecsys® HIV combi PT assay was compared with fourth- (ADVIA Centaur® HIV combo, ARCHITECT® HIV combo, Elecsys® HIV combi) and third-generation (VIRONOSTIKA® HIV Uni-Form II Plus O, Zhuhai Livzon Anti-HIV EIA, Serodia® Particle Agglutination) assays commonly used in the region. RESULTS: Overall, the Elecsys® HIV combi PT showed superior or similar sensitivity to the comparators for detecting all subtypes. The assay correctly identified all positive samples, including those taken soon after infection, and detected seroconversion at a similar or shorter time interval than the comparators. The analytical sensitivity of Elecsys® HIV combi PT for HIV-1 p24 antigen was 0.90 IU/mL, which was lower than reported previously. The assay showed good specificity (99.86%) that was superior or equivalent to the other fourth-generation assays tested. CONCLUSIONS: These robust data demonstrate the good subtype inclusivity of the Elecsys® HIV combi PT assay and its suitability for screening and reliable early detection of HIV infection in Asia.


Subject(s)
Clinical Laboratory Techniques/methods , HIV Infections/diagnosis , HIV-1/isolation & purification , Asia , Early Diagnosis , Humans , Immunoassay/methods , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL