Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.739
Filter
1.
Proc Natl Acad Sci U S A ; 120(18): e2220036120, 2023 05 02.
Article in English | MEDLINE | ID: mdl-37094132

ABSTRACT

SNIO-CBP, a single-nanometer iron oxide (SNIO) nanoparticle functionalized with a type I collagen-binding peptide (CBP), was developed as a T1-weighted MRI contrast agent with only endogenous elements for fast and noninvasive detection of liver fibrosis. SNIO-CBP exhibits 6.7-fold higher relaxivity compared to a molecular gadolinium-based collagen-binding contrast agent CM-101 on a per CBP basis at 4.7 T. Unlike most iron oxide nanoparticles, SNIO-CBP exhibits fast elimination from the bloodstream with a 5.7 min half-life, high renal clearance, and low, transient liver enhancement in healthy mice. We show that a dose of SNIO-CBP that is 2.5-fold lower than that for CM-101 has comparable imaging efficacy in rapid (within 15 min following intravenous injection) detection of hepatotoxin-induced liver fibrosis using T1-weighted MRI in a carbon tetrachloride-induced mouse liver injury model. We further demonstrate the applicability of SNIO-CBP in detecting liver fibrosis in choline-deficient L-amino acid-defined high-fat diet mouse model of nonalcoholic steatohepatitis. These results provide a platform with potential for the development of high relaxivity, gadolinium-free molecular MRI probes for characterizing chronic liver disease.


Subject(s)
Magnetite Nanoparticles , Nanoparticles , Mice , Animals , Contrast Media/chemistry , Liver Cirrhosis/pathology , Liver/pathology , Magnetic Resonance Imaging/methods , Disease Models, Animal , Magnetic Iron Oxide Nanoparticles , Collagen/analysis
2.
Nano Lett ; 24(22): 6696-6705, 2024 Jun 05.
Article in English | MEDLINE | ID: mdl-38796774

ABSTRACT

Ultra-high-field (UHF) magnetic resonance imaging (MRI) stands as a pivotal cornerstone in biomedical imaging, yet the challenge of false imaging persists, constraining its full potential. Despite the development of dual-mode contrast agents improving conventional MRI, their effectiveness in UHF remains suboptimal due to the high magnetic moment, resulting in diminished T1 relaxivity and excessively enhanced T2 relaxivity. Herein, we report a DNA-mediated magnetic-dimer assembly (DMA) of iron oxide nanoparticles that harnesses UHF-tailored nanomagnetism for fault-free UHF-MRI. DMA exhibits a dually enhanced longitudinal relaxivity of 4.42 mM-1·s-1 and transverse relaxivity of 26.23 mM-1·s-1 at 9 T, demonstrating a typical T1-T2 dual-mode UHF-MRI contrast agent. Importantly, DMA leverages T1-T2 dual-modality image fusion to achieve artifact-free breast cancer visualization, effectively filtering interference from hundred-micrometer-level false-positive signals with unprecedented precision. The UHF-tailored T1-T2 dual-mode DMA contrast agents hold promise for elevating the accuracy of MR imaging in disease diagnosis.


Subject(s)
Contrast Media , DNA , Magnetic Resonance Imaging , Magnetic Resonance Imaging/methods , Contrast Media/chemistry , Humans , DNA/chemistry , Mice , Magnetic Iron Oxide Nanoparticles/chemistry , Female , Animals , Breast Neoplasms/diagnostic imaging , Magnetite Nanoparticles/chemistry , Cell Line, Tumor
3.
Osteoarthritis Cartilage ; 32(3): 299-309, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38061579

ABSTRACT

OBJECTIVE: Cationic tantalum oxide nanoparticles (Ta2O5-cNPs), as a newly introduced contrast agent for computed tomography of cartilage, offer quantitative evaluation of proteoglycan (PG) content and biomechanical properties. However, knowledge on the depth-wise impact of cartilage constituents on nanoparticle diffusion, particularly the influence of the collagen network, is lacking. In this study, we aim to establish the depth-dependent relationship between Ta2O5-cNP diffusion and cartilage constituents (PG content, collagen content and network architecture). METHODS: Osteochondral samples (n = 30) were harvested from healthy equine stifle joints (N = 15) and the diffusion of 2.55 nm diameter cationic Ta2O5-cNPs into the cartilage was followed with micro computed tomography (µCT) imaging for up to 96 hours. The diffusion-related parameters, Ta2O5-cNP maximum partition (Pmax) and diffusion time constant, were compared against biomechanical and depth-wise structural properties. Biomechanics were assessed using stress-relaxation and sinusoidal loading protocols, whereas PG content, collagen content and collagen network architecture were determined using digital densitometry, Fourier-transform infrared spectroscopy and polarized light microscopy, respectively. RESULTS: The Pmax correlates with the depth-wise distribution of PGs (bulk Spearman's ρ = 0.87, p < 0.001). More open collagen network architecture at the superficial zone enhances intake of Ta2O5-cNPs, but collagen content overall decreases the intake. The Pmax values correlate with the equilibrium modulus (ρ = 0.80, p < 0.001) of articular cartilage. CONCLUSION: This study establishes the feasibility of Ta2O5-cNPs for the precise and comprehensive identification of biomechanical and structural changes in articular cartilage via contrast-enhanced µCT.


Subject(s)
Cartilage, Articular , Oxides , Tantalum , Animals , Horses , Cartilage, Articular/diagnostic imaging , Contrast Media , X-Ray Microtomography , Proteoglycans , Collagen
4.
BMC Cancer ; 24(1): 422, 2024 Apr 05.
Article in English | MEDLINE | ID: mdl-38580944

ABSTRACT

BACKGROUND: As comprehensive surgical management for gastric cancer becomes increasingly specialized and standardized, the precise differentiation between ≤T1 and ≥T2 gastric cancer before endoscopic intervention holds paramount clinical significance. OBJECTIVE: To evaluate the diagnostic efficacy of contrast-enhanced gastric ultrasonography in differentiating ≤T1 and ≥T2 gastric cancer. METHODS: PubMed, Web of Science, and Medline were searched to collect studies published from January 1, 2000 to March 16, 2023 on the efficacy of either double contrast-enhanced gastric ultrasonography (D-CEGUS) or oral contrast-enhanced gastric ultrasonography (O-CEGUS) in determining T-stage in gastric cancer. The articles were selected according to specified inclusion and exclusion criteria, and the quality of the included literature was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 scale. Meta-analysis was performed using Stata 12 software with data from the 2 × 2 crosslinked tables in the included literature. RESULTS: In total, 11 papers with 1124 patients were included in the O-CEGUS analysis, which revealed a combined sensitivity of 0.822 (95% confidence interval [CI] = 0.753-0.875), combined specificity of 0.964 (95% CI = 0.925-0.983), and area under the summary receiver operating characteristic (sROC) curve (AUC) of 0.92 (95% CI = 0.89-0.94). In addition, five studies involving 536 patients were included in the D-CEGUS analysis, which gave a combined sensitivity of 0.733 (95% CI = 0.550-0.860), combined specificity of 0.982 (95% CI = 0.936-0.995), and AUC of 0.93 (95% CI = 0.91-0.95). According to the I2 and P values ​​of the forest plot, there was obvious heterogeneity in the combined specificities of the included papers. Therefore, the two studies with the lowest specificities were excluded from the O-CEGUS and D-CEGUS analyses, which eliminated the heterogeneity among the remaining literature. Consequently, the combined sensitivity and specificity of the remaining studies were 0.794 (95% CI = 0.710-0.859) and 0.976 (95% CI = 0.962-0.985), respectively, for the O-CEDUS studies and 0.765 (95% CI = 0.543-0.899) and 0.986 (95% CI = 0.967-0.994), respectively, for the D-CEGUS studies. The AUCs were 0.98 and 0.99 for O-CEGUS and D-CEGUS studies, respectively. CONCLUSION: Both O-CEGUS and D-CEGUS can differentiate ≤T1 gastric cancer from ≥T2 gastric cancer, thus assisting the formulation of clinical treatment strategies for patients with very early gastric cancer. Given its simplicity and cost-effectiveness, O-CEGUS is often favored as a staging method for gastric cancer prior to endoscopic intervention.


Subject(s)
Contrast Media , Neoplasm Staging , Stomach Neoplasms , Ultrasonography , Stomach Neoplasms/diagnostic imaging , Stomach Neoplasms/pathology , Humans , Ultrasonography/methods , Sensitivity and Specificity , ROC Curve , Stomach/diagnostic imaging , Stomach/pathology
5.
J Magn Reson Imaging ; 2024 Apr 10.
Article in English | MEDLINE | ID: mdl-38597340

ABSTRACT

Over the past few years, a large number of studies have evidenced increased signal intensity in the deep brain nuclei on unenhanced T1-MRI images achieved by the application of gadolinium-based contrast agents (GBCAs). The deposition of gadolinium in the brain, bone, and other tissues following administration of GBCAs has also been confirmed in histological studies in rodents and in necropsy studies in adults and children. Given the distinct physiological characteristics of children, this review focuses on examining the current research on gadolinium deposition in children, particularly studies utilizing novel methods and technologies. Furthermore, the article compares safety research findings of linear GBCAs and macrocyclic GBCAs in children, with the aim of offering clinicians practical guidance based on the most recent research outcomes. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY: Stage 2.

6.
Muscle Nerve ; 69(3): 334-339, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38197490

ABSTRACT

INTRODUCTION/AIMS: The performance of magnetic resonance imaging (MRI) for diagnosing suspected idiopathic inflammatory myopathy (IIM) remains controversial. Furthermore, the role of contrast-enhanced magnetic resonance imaging (CE-MRI) sequences is unclear. The aim of this study was to evaluate the sensitivity and specificity of a non-enhanced magnetic resonance imaging (NE-MRI) protocol compared to a CE-MRI protocol in adult patients with confirmed IIM. METHODS: This study retrospectively enrolled patients with suspected IIM who underwent MRI of the upper thigh between 2008 and 2020. The protocol consisted of a T1-weighted (T1w) sequence, a turbo inversion recovery magnitude (TIRM) sequence and a contrast-enhanced T1-weighted sequence (CE-T1w). After randomly stratifying patients into a group with only the T1w and TIRM sequences available and another group with additional availability of CE-T1w, three blinded readers assessed the presence of IIM based on characteristic imaging features. Confirmation of the diagnosis was determined based on the 2017 ACR/EULAR criteria. RESULTS: Of the 80 patients (mean age 49.0 ± 21.1 years; 42 female, 38 male) included, 54 (67.5%) had a positive diagnosis of IIM. Cumulated sensitivity and specificity for MRI to detect IIM was 87.1% and 83.3% in the NE-MRI group versus 87.0% and 63.0% in the CE-MRI group. The group differences for sensitivity and specificity were non-significant for each of the three readers, respectively (p ≥ .081). DISCUSSION: NE-MRI detects suspected IIM with high diagnostic accuracy and performs equivalently to CE-MRI. Therefore, it may be appropriate to omit the use of contrast agents in MRI scans performed for suspected IIM.


Subject(s)
Magnetic Resonance Imaging , Myositis , Humans , Adult , Male , Female , Middle Aged , Aged , Retrospective Studies , Magnetic Resonance Imaging/methods , Myositis/diagnostic imaging , Sensitivity and Specificity , Thigh , Contrast Media
7.
J Comput Aided Mol Des ; 38(1): 17, 2024 Apr 03.
Article in English | MEDLINE | ID: mdl-38570405

ABSTRACT

The development of peptides for therapeutic targets or biomarkers for disease diagnosis is a challenging task in protein engineering. Current approaches are tedious, often time-consuming and require complex laboratory data due to the vast search spaces that need to be considered. In silico methods can accelerate research and substantially reduce costs. Evolutionary algorithms are a promising approach for exploring large search spaces and can facilitate the discovery of new peptides. This study presents the development and use of a new variant of the genetic-programming-based POET algorithm, called POET Regex , where individuals are represented by a list of regular expressions. This algorithm was trained on a small curated dataset and employed to generate new peptides improving the sensitivity of peptides in magnetic resonance imaging with chemical exchange saturation transfer (CEST). The resulting model achieves a performance gain of 20% over the initial POET models and is able to predict a candidate peptide with a 58% performance increase compared to the gold-standard peptide. By combining the power of genetic programming with the flexibility of regular expressions, new peptide targets were identified that improve the sensitivity of detection by CEST. This approach provides a promising research direction for the efficient identification of peptides with therapeutic or diagnostic potential.


Subject(s)
Algorithms , Magnetic Resonance Imaging , Humans , Phantoms, Imaging , Magnetic Resonance Imaging/methods , Peptides
8.
MAGMA ; 2024 May 25.
Article in English | MEDLINE | ID: mdl-38795276

ABSTRACT

OBJECTIVE: Glioblastoma multiforme is a highly aggressive form of brain cancer, and early diagnosis plays a pivotal role in improving patient survival rates. In this regard, molecular magnetic resonance imaging has emerged as a promising imaging modality due to its exceptional sensitivity to minute tissue changes and the ability to penetrate deep into the brain. This study aimed to assess the efficacy of a novel contrast agent in detecting gliomas during MRI scans. MATERIALS AND METHODS: The contrast agent utilized modified chitosan coating on manganese oxide nanoparticles. The modification included adding methotrexate and 5-aminolevulinic acid (MnO2/CS@5-ALA-MTX) to target cells with overexpressed folate receptors and breaking down excess hydrogen peroxide in tumor tissue, resulting in enhanced signal intensity in T1-weighted MR images but diminished signal intensity in T2*-weighted MR images. RESULTS: The nanosystem was characterized and evaluated in MR imaging, safety, and ability to target cells both in vivo and in vitro. MTX-free nanoparticles (MnO2/CS@5-ALA NPs) had no obvious cytotoxicity on cell lines U87MG and NIH3T3 after 24/48 h at a concentration of up to 160 µgr/mL (cell viability more than 80%). In this system, methotrexate enables tumor targeting and the MnO2/5-ALA improves T1-T2*-weighted MRI. In addition, MRI scans of mice with M109 carcinoma indicated significant tumor uptake and NP capacity to improve the positive contrast effect. CONCLUSION: This developed MnO2/CS@5-ALA-MTX nanoparticle system may exhibit great potential in the accurate diagnosis of folate receptor over-expressing cancers such as glioblastoma.

9.
BMC Med Imaging ; 24(1): 88, 2024 Apr 13.
Article in English | MEDLINE | ID: mdl-38615005

ABSTRACT

PURPOSE: This study investigated and compared the effects of Gd enhancement on brain tumours with a half-dose of contrast medium at 5.0 T and with a full dose at 3.0 T. METHODS: Twelve subjects diagnosed with brain tumours were included in this study and underwent MRI after contrast agent injection at 3.0 T (full dose) or 5.0 T (half dose) with a 3D T1-weighted gradient echo sequence. The postcontrast images were compared by two independent neuroradiologists in terms of the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and subjective image quality score on a ten-point Likert scale. Quantitative indices and subjective quality ratings were compared with paired Student's t tests, and interreader agreement was assessed with the intraclass correlation coefficient (ICC). RESULTS: A total of 16 enhanced tumour lesions were detected. The SNR was significantly greater at 5.0 T than at 3.0 T in grey matter, white matter and enhanced lesions (p < 0.001). The CNR was also significantly greater at 5.0 T than at 3.0 T for grey matter/tumour lesions, white matter/tumour lesions, and grey matter/white matter (p < 0.001). Subjective evaluation revealed that the internal structure and outline of the tumour lesions were more clearly displayed with a half-dose at 5.0 T (Likert scale 8.1 ± 0.3 at 3.0 T, 8.9 ± 0.3 at 5.0 T, p < 0.001), and the effects of enhancement in the lesions were comparable to those with a full dose at 3.0 T (7.8 ± 0.3 at 3.0 T, 8.7 ± 0.4 at 5.0 T, p < 0.001). All subjective scores were good to excellent at both 5.0 T and 3.0 T. CONCLUSION: Both quantitative and subjective evaluation parameters suggested that half-dose enhanced scanning via 5.0 T MRI might be feasible for meeting clinical diagnostic requirements, as the image quality remains optimal. Enhanced scanning at 5.0 T with a half-dose of contrast agents might benefit patients with conditions that require less intravenous contrast agent, such as renal dysfunction.


Subject(s)
Brain Neoplasms , Contrast Media , Humans , Feasibility Studies , Brain Neoplasms/diagnostic imaging , Gray Matter , Radiologists
10.
BMC Nephrol ; 25(1): 226, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-39009991

ABSTRACT

BACKGROUND: Contrast-induced acute kidney injury (CI-AKI) is an acute renal complication that occurs after intravascular contrast agent administration. Sodium selenite (SS) is an inorganic source of Se and has potent antioxidant properties. This study intends to examine its anti-inflammatory and antioxidant effects in CI-AKI. METHODS: A rat CI-AKI model was established with the pretreatment of SS (0.35 mg/kg). Hematoxylin-eosin staining was employed for histopathological analysis of rat kidney specimens. Biochemical analysis was conducted for renal function detection. Tissue levels of oxidative stress-related markers were estimated. Reverse transcription-quantitative polymerase chain reaction revealed the mRNA levels of proinflammatory cytokines. Western blotting showed the Nrf2 signaling-related protein expression in the rat kidney. RESULTS: SS administration alleviated the renal pathological changes and reduced the serum levels of serum creatinine, blood urea nitrogen, neutrophil gelatinase-associated lipocalin, cystatin C, and urinary level of kidney injury molecule-1 in CI-AKI rats. SS attenuated oxidative stress and inflammatory response in CI-AKI rat kidney tissues. SS activated the Nrf2 signaling transduction in the renal tissues of rats with CI-AKI. CONCLUSION: SS ameliorates CI-AKI in rats by reducing oxidative stress and inflammation via the Nrf2 signaling.


Subject(s)
Acute Kidney Injury , Contrast Media , NF-E2-Related Factor 2 , Oxidative Stress , Rats, Sprague-Dawley , Signal Transduction , Sodium Selenite , Animals , Acute Kidney Injury/chemically induced , Acute Kidney Injury/metabolism , Acute Kidney Injury/prevention & control , Acute Kidney Injury/pathology , Oxidative Stress/drug effects , NF-E2-Related Factor 2/metabolism , Rats , Male , Contrast Media/adverse effects , Signal Transduction/drug effects , Sodium Selenite/pharmacology , Sodium Selenite/therapeutic use , Antioxidant Response Elements , Inflammation/metabolism , Antioxidants/pharmacology , Antioxidants/therapeutic use , Creatinine/blood
11.
Proc Natl Acad Sci U S A ; 118(41)2021 10 12.
Article in English | MEDLINE | ID: mdl-34607942

ABSTRACT

Type 1 diabetes (T1D) results from immune infiltration and destruction of insulin-producing ß cells within the pancreatic islets of Langerhans (insulitis). Early diagnosis during presymptomatic T1D would allow for therapeutic intervention prior to substantial ß-cell loss at onset. There are limited methods to track the progression of insulitis and ß-cell mass decline. During insulitis, the islet microvasculature increases permeability, such that submicron-sized particles can extravasate and accumulate within the islet microenvironment. Ultrasound is a widely deployable and cost-effective clinical imaging modality. However, conventional microbubble contrast agents are restricted to the vasculature. Submicron nanodroplet (ND) phase-change agents can be vaporized into micron-sized bubbles, serving as a microbubble precursor. We tested whether NDs extravasate into the immune-infiltrated islet microenvironment. We performed ultrasound contrast-imaging following ND infusion in nonobese diabetic (NOD) mice and NOD;Rag1ko controls and tracked diabetes development. We measured the biodistribution of fluorescently labeled NDs, with histological analysis of insulitis. Ultrasound contrast signal was elevated in the pancreas of 10-wk-old NOD mice following ND infusion and vaporization but was absent in both the noninfiltrated kidney of NOD mice and the pancreas of Rag1ko controls. High-contrast elevation also correlated with rapid diabetes onset. Elevated contrast was also observed as early as 4 wk, prior to mouse insulin autoantibody detection. In the pancreata of NOD mice, infiltrated islets and nearby exocrine tissue were selectively labeled with fluorescent NDs. Thus, contrast ultrasound imaging with ND phase-change agents can detect insulitis prior to diabetes onset. This will be important for monitoring disease progression, to guide and assess preventative therapeutic interventions for T1D.


Subject(s)
Contrast Media/chemistry , Diabetes Mellitus, Type 1/diagnosis , Diabetes Mellitus, Type 1/pathology , Insulin-Secreting Cells/pathology , Islets of Langerhans/blood supply , Ultrasonography/methods , Animals , Autoantibodies/analysis , Early Diagnosis , Female , Homeodomain Proteins/genetics , Mice , Mice, Inbred NOD , Mice, Knockout , Microbubbles
12.
Curr Heart Fail Rep ; 21(2): 63-72, 2024 04.
Article in English | MEDLINE | ID: mdl-38305851

ABSTRACT

PURPOSE OF REVIEW: The application of ultrasound-enhancing agents (contrast agents) has improved the accuracy and reproducibility of echocardiography. The review focuses on the currently approved and evolving indications for contrast echocardiography in patients with heart failure, specifically examining clinical studies conducted after the publication of the guidelines in 2017 and 2018. RECENT FINDINGS: The current ASE/EACVI recommendations for contrast echocardiography are based on its accuracy and reproducibility in comparison to non-enhanced echocardiography or other imaging modalities like cardiac MRI. However, tissue characterization remains limited with contrast echocardiography. During the last few years, several studies have demonstrated the clinical impact of using contrast agents on the management of patients with heart failure. There is growing evidence on the benefit of using contrast echocardiography in critically ill patients where echocardiography without contrast agents is often suboptimal and other imaging methods are less feasible. There is no risk of worsening renal function after the administration of ultrasound-enhancing agents, and these agents can be administered even in patients with end-stage renal disease. Contrast echocardiography has become a valuable tool for first-line imaging of patients with heart failure across the spectrum of patients with chronic heart failure to critically ill patients.


Subject(s)
Heart Failure , Humans , Heart Failure/diagnostic imaging , Heart Failure/drug therapy , Contrast Media , Reproducibility of Results , Critical Illness , Echocardiography/methods , Ventricular Function, Left
13.
J Appl Clin Med Phys ; 25(4): e14324, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38470449

ABSTRACT

PURPOSE: This study aimed to elucidate whether gadolinium contrast in clinically relevant doses can be used with photon-counting computed tomography (PCCT) as an alternative contrast agent in clinical applications. MATERIAL/METHODS: A CTDI phantom with 3D printed rods filled with different concentrations of gadolinium and iodine contrast was scanned in a PCCT and an energy-integrated computed tomography (EICT). Attenuation values at different monoenergetic steps were extracted for each contrast concentration. RESULTS: For PCCT, gadolinium reached an attenuation >100 HU (103 HU) at 40 keV with a concentration 5 mmol/L whereas the same level was reached at 50 keV (118 HU) for 10 mmol/L and 90 keV (114 HU) for 25 mmol/L. For iodine, the same level of attenuation was reached at 100 keV (106 HU) with a concentration 8.75 mg I/mL. For EICT the lowest gadolinium contrast concentration needed to reach >100 HU (108 HU) was 10 mmol/L at 50 keV. For 25 mmol/L 100 HU was reached at 100 keV. For iodine contrast 108 HU was reached at 110 keV for 8.75 mg I/mL. CONCLUSION: No K-edge potential or difference in attenuation curves between iodine and gadolinium contrast is detected on the first clinical available PCCT. Clinically relevant attenuation levels were barely achieved in this setting with gadolinium concentrations approved for human use. The results of this study suggest that, given current scanning technology, gadolinium is not a clinically useful contrast agent for computed tomography because no K-edge was detected.


Subject(s)
Contrast Media , Iodine , Humans , Gadolinium , Tomography, X-Ray Computed/methods , Phantoms, Imaging
14.
Emerg Radiol ; 2024 Jul 29.
Article in English | MEDLINE | ID: mdl-39073730

ABSTRACT

PURPOSE: This study aimed to identify the radiological CT findings that are significantly correlated with the outcome of conservative management with oral water-soluble contrast medium in patients presenting with Adhesive Small Bowel Obstruction (ASBO) to the Emergency Room. METHODS: In this retrospective single-center study, we considered all consecutive patients admitted to the ER from February 2019 to February 2023 for ASBO with an available contrast-enhanced CT scan performed at diagnosis and treated with conservative management. The investigated CT findings were type and location of transition zone, ASBO degree, fat notch sign, beak sign, small bowel feces sign, presence of peritoneal free fluid and pneumatosis intestinalis. Radiological parameters were analyzed using univariable and multivariable logistic regression to test the significant association between the CT parameters and the target. RESULTS: Among the 106 included patients (median age 74.5 years), conservative treatment was effective in 59 (55.7%) and failed in 47 (44.3%), needing delayed surgery. In the failure group, there was a higher prevalence of patients who had previous ASBO episodes (p = 0.03), a greater proportion of females (p = 0.04) and a longer hospital stay (p < 0.001). At multivariable analysis, two CT findings were significantly correlated with failure of conservative treatment: fat notch sign (OR = 2.95; p = 0.04) and beak sign (OR = 3.42; p = 0.04). CONCLUSIONS: Two radiological signs correlate with failure of non-operative management in ASBO, suggesting their importance in surgical decision-making. Patients presenting with these signs are at higher risk of unsuccessful conservative treatment and may require undelayed surgical intervention.

15.
J Clin Ultrasound ; 52(3): 230-240, 2024.
Article in English | MEDLINE | ID: mdl-38018362

ABSTRACT

OBJECTIVES: To identify characteristics of preoperative contrast-enhanced ultrasound (CEUS) that could predict early recurrence after curative resection of pancreatic ductal adenocarcinoma (PDAC). METHODS: From January 2017 to September 2022, a total of 110 patients with PDAC (all confirmed by samples obtained via operation) who underwent CEUS within 1 month before surgery were enrolled. We proposed five CEUS enhancement patterns (Pattern I, homogeneous enhancement; Pattern II, heterogeneous enhancement without cystic components; pattern III, ring enhancement; Pattern IV, starry enhancement; Pattern V, heterogeneous enhancement with cystic components) of PDAC. Clinical-pathologic and CEUS characteristics for predicting early recurrence (recurrence within 1 year after curative resection) were analyzed. Important CEUS characteristics were compared with the pathological findings. RESULTS: Tumor size and TNM stage were closely associated with early recurrence. Incomplete-enhancement and enhancement pattern III, IV and V at CEUS imaging were more prone to early recurrence. Incomplete-enhancement lesions had higher histological tumor grades, less frequent remaining acini, and more frequent necrosis within the tumor. PDACs with pattern I and II had lower histological tumor grades, and pattern III, IV and V had higher histological tumor grades. PDACs with pattern I, II and IV had less frequent intratumoral necrosis than PDACs with pattern III and V, and PDACs with pattern IV had lower MVD values. CONCLUSIONS: PDACs with incomplete enhancement and enhancement pattern III, IV and V were more prone to early recurrence after attempted curative resection, and these important CEUS characteristics were closely related to the pathological findings of PDAC.


Subject(s)
Adenocarcinoma , Pancreatic Neoplasms , Humans , Pancreatic Neoplasms/diagnostic imaging , Pancreatic Neoplasms/surgery , Ultrasonography/methods , Necrosis , Contrast Media , Retrospective Studies
16.
J Clin Ultrasound ; 52(6): 763-772, 2024.
Article in English | MEDLINE | ID: mdl-38660883

ABSTRACT

PURPOSE: Contrast-enhanced duplex ultrasound (CEUS) might be a useful tool to diagnosing renal artery stenosis (RAS). We amalgamated and reviewed the evidence assessing the diagnostic accuracy of CEUS on detecting RAS compared to angiography. METHODS: This preregistered systematic review included studies that compared the presence of RAS via CEUS with angiography. Sources were searched in November 2022 and included Scopus, EMBASE, MEDLINE, CINAHL, and Academic Search Premier (n = 1717). The Quality Assessment of Diagnostic Studies 2 tool assessed study quality. Results are presented narratively. RESULTS: The studies included (n = 11) had a total of 447 unique participants (193 females) and average age of 56 ± 9 years. Five of eleven studies investigated CEUS using SonoVue contrast agent and reported an average accuracy (91% ± 2%), sensitivity (91% ± 3%), specificity (90% ± 5%), negative predictive value (86% ± 6%), and positive predictive value (94% ± 1%) with all values >80%. The accuracy of CEUS using other types of contrast agent (n = 6), including Levovsit (n = 3/6), Definity (n = 1/6), perfienapent emulsion (n = 1/6), and perfluorocarbon-exposed sonicated dextrose albumin (n = 1/6) was mixed. These studies detected an average accuracy of 91 ± 11% (n = 2/3% > 80%), sensitivity of 98% ± 4%, (n = 3/3% > 80%), and specificity of 86% ± 10% (n = 2/3% > 80%). Included studies had generally low risk of bias and applicability concerns except for unclear flow and timing (n = 7/11) and applicability of patient selection (n = 4/11). CONCLUSION: Despite being limited by the heterogeneity of included studies, our review indicates a high overall diagnostic accuracy for CEUS to detect RAS compared to angiography, with the largest evidence-base for SonoVue contrast. Radiologists and hospital decision makers should consider CEUS as an acceptable alternative to angiography.


Subject(s)
Contrast Media , Renal Artery Obstruction , Ultrasonography, Doppler, Duplex , Humans , Renal Artery Obstruction/diagnostic imaging , Ultrasonography, Doppler, Duplex/methods , Reproducibility of Results , Sensitivity and Specificity , Renal Artery/diagnostic imaging , Image Enhancement/methods
17.
Nano Lett ; 23(12): 5497-5505, 2023 06 28.
Article in English | MEDLINE | ID: mdl-37300521

ABSTRACT

Nanostructured contrast agents are promising alternatives to Gd3+-based chelates in magnetic resonance (MR) imaging techniques. A novel ultrasmall paramagnetic nanoparticle (UPN) was strategically designed to maximize the number of exposed paramagnetic sites and r1 while minimizing r2, by decorating 3 nm titanium dioxide nanoparticles with suitable amounts of iron oxide. Its relaxometric parameters are comparable to those of gadoteric acid (GA) in agar phantoms, and the r2/r1 ratio of 1.38 at 3 T is close to the ideal unitary value. The strong and prolonged contrast enhancement of UPN before renal excretion was confirmed by T1-weighted MR images of Wistar rats after intravenous bolus injection. Those results associated with good biocompatibility indicate its high potential as an alternative blood-pool contrast agent to the GA gold standard for MR angiography, especially for patients with severe renal impairment.


Subject(s)
Contrast Media , Magnetic Resonance Angiography , Rats , Animals , Gadolinium , Rats, Wistar , Magnetic Resonance Imaging/methods , Chelating Agents
18.
Nano Lett ; 23(13): 6178-6183, 2023 07 12.
Article in English | MEDLINE | ID: mdl-37363812

ABSTRACT

Apoptosis, with a hallmark of upregulated protease Caspase-3, has been frequently imaged with various probes to reveal the therapeutic efficiencies of different drugs. However, activatable molecular probes with programmable self-assembling behaviors that enable enhanced T1-weighted magnetic resonance imaging (MRI) of apoptosis remain scarce. Herein, taking advantage of a CBT-Cys click reaction, we rationally designed a Caspase-3-activatable self-assembling probe Ac-Asp-Glu-Val-Asp-Cys(StBu)-Lys(DOTA(Gd))-CBT (DEVDCS-Gd-CBT) for apoptosis imaging in vivo. After Caspase-3 cleavage in apoptotic cells, DEVDCS-Gd-CBT underwent CBT-Cys click reaction to form a cyclic dimer, which self-assembled into Gd nanoparticles. With this probe, enhanced T1-weighted MR images of apoptosis were achieved at low magnetic fields in vitro, in cis-dichlorodiamineplatinum-induced apoptotic cells and in tail-amputation-simulated apoptotic zebrafish. We anticipate that the smart probe DEVDCS-Gd-CBT could be applied for T1-weighted MRI of apoptosis-related diseases in the clinic in the future.


Subject(s)
Gadolinium , Nanoparticles , Animals , Caspase 3 , Zebrafish , Magnetic Resonance Imaging/methods , Apoptosis , Contrast Media
19.
Nano Lett ; 23(18): 8628-8636, 2023 09 27.
Article in English | MEDLINE | ID: mdl-37694968

ABSTRACT

Magnetic resonance imaging (MRI) is an important tool in the diagnosis of many cancers. However, clinical gadolinium (Gd)-based MRI contrast agents have limitations, such as large doses and potential side effects. To address these issues, we developed a hydrogen-bonded organic framework-based MRI contrast agent (PFC-73-Mn). Due to the hydrogen-bonded interaction of water molecules and the restricted rotation of manganese ions, PFC-73-Mn exhibits high longitudinal relaxation r1 (5.03 mM-1 s-1) under a 3.0 T clinical MRI scanner. A smaller intravenous dose (8 µmol of Mn/kg) of PFC-73-Mn can provide strong contrast and accurate diagnosis in multiple kinds of cancers, including breast tumor and ultrasmall orthotopic glioma. PFC-73-Mn represents a prospective new approach in tumor imaging, especially in early-stage cancer.


Subject(s)
Glioma , Manganese , Humans , Contrast Media , Gadolinium , Magnetic Resonance Imaging/methods
20.
Int J Mol Sci ; 25(4)2024 Feb 09.
Article in English | MEDLINE | ID: mdl-38396789

ABSTRACT

Pyridoxine (pyr) is a versatile molecule that forms part of the family of B vitamins. It is used to treat and prevent vitamin B6 deficiency and certain types of metabolic disorders. Moreover, the pyridoxine molecule has been investigated as a suitable ligand toward metal ions. Nevertheless, the study of the magnetic properties of metal complexes containing lanthanide(III) ions and this biomolecule is unexplored. We have synthesized and characterized a novel pyridoxine-based GdIII complex of formula [GdIII(pyr)2(H2O)4]Cl3 · 2 H2O (1) [pyr = pyridoxine]. 1 crystallizes in the triclinic system and space group Pi. In its crystal packing, cationic [Gd(pyr)2(H2O)4]3+ entities are connected through H-bonding interactions involving non-coordinating water molecules and chloride anions. In addition, Hirshfeld surfaces of 1 were calculated to further investigate their intermolecular interactions in the crystal lattice. Our investigation of the magnetic properties of 1, through ac magnetic susceptibility measurements, reveals the occurrence of a slow relaxation in magnetization in this mononuclear GdIII complex, indicating an unusual single-ion magnet (SIM) behavior for this pseudo-isotropic metal ion at very low temperatures. We also studied the relaxometric properties of 1, as a potential contrast agent for high-field magnetic resonance imaging (MRI), from solutions of 1 prepared in physiological serum (0.0-3.2 mM range) and measured at 3 T on a clinical MRI scanner. The values of relaxivity obtained for 1 are larger than those of some commercial MRI contrast agents based on mononuclear GdIII systems.


Subject(s)
Gadolinium , Pyridoxine , Gadolinium/chemistry , Magnets , Magnetic Resonance Imaging/methods , Ions
SELECTION OF CITATIONS
SEARCH DETAIL