Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 2.472
Filter
Add more filters

Publication year range
1.
BMC Cardiovasc Disord ; 24(1): 342, 2024 Jul 05.
Article in English | MEDLINE | ID: mdl-38970014

ABSTRACT

BACKGROUND: The trans femoral ipsilateral approach is often adopted for endovascular treatment (EVT) for better steerability of guidewires or better device deliverability. However, contrary to the trans femoral contralateral approach, ipsilateral antegrade puncture sometimes causes peculiar bleeding complications. CASE PRESENTATION: A 76-year-old female underwent EVT for chronic occlusion of the left superficial femoral artery (SFA) via the ipsilateral antegrade approach. After guidewire passage, we inflated the drug-coated balloons, but angiography showed blood flow stasis at the mid segment of the SFA. We also ensured prolonged balloon inflation, which resulted in favorable blood flow. While trying to ensure hemostasis, the blood pressure remained decreased, but neither bleeding nor superficial hematoma were observed at the puncture site. After hemostasis was achieved, we removed the surgical drape and noticed a swelling in the mid-portion of the thigh, distant from the puncture point. We then approached the left common femoral artery (CFA) contralaterally. Angiography showed continuous bleeding from a little bit distally to the sheath insertion point that was spreading through an intramuscular space. We stopped the bleeding with balloon tamponade inside the CFA. Angiography after hemostasis demonstrated blood flow stasis at the mid-segment of the SFA, similarly as that seen before. We confirmed compression of the SFA by a large hematoma using both intra- and extra- vascular ultrasound. Therefore, we deployed a self-expandable stent at the compressed SFA position. Finally, we achieved favorable blood flow on angiography. CONCLUSION: We encountered a case that latent bleeding unrecognized in the surgical field persisted while prolonged inflation of DCB was conducted at just proximal SFA. We could have avoided bailout stenting by noticing the bleeding incident in a timely manner. Prediction and prevention are essential for all kinds of procedural complications in EVT.


Subject(s)
Delayed Diagnosis , Femoral Artery , Hemorrhage , Punctures , Humans , Female , Aged , Femoral Artery/diagnostic imaging , Hemorrhage/etiology , Hemorrhage/therapy , Treatment Outcome , Peripheral Arterial Disease/therapy , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/physiopathology , Predictive Value of Tests , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/instrumentation , Endovascular Procedures/instrumentation , Endovascular Procedures/adverse effects , Hemostatic Techniques/instrumentation , Hemostatic Techniques/adverse effects
2.
Cochrane Database Syst Rev ; 5: CD013023, 2024 05 23.
Article in English | MEDLINE | ID: mdl-38780138

ABSTRACT

BACKGROUND: Peripheral arterial catheters (ACs) are used in anaesthesia and intensive care settings for blood sampling and monitoring. Despite their importance, ACs often fail, requiring reinsertion. Dressings and securement devices maintain AC function and prevent complications such as infection. OBJECTIVES: To evaluate the effectiveness of peripheral AC dressing and securement devices to prevent failure and complications in hospitalised people. SEARCH METHODS: We searched the Cochrane Wounds Specialised Register, CENTRAL, MEDLINE, Embase, and CINAHL Plus up to 16 May 2023. We also searched ClinicalTrials.gov and the World Health Organization International Clinical Trials Registry Platform up to 16 May 2023. SELECTION CRITERIA: We included randomised controlled trials (RCTs) comparing different dressing and securement devices for the stabilisation of ACs in hospitalised people. DATA COLLECTION AND ANALYSIS: Two review authors independently selected trials for inclusion, extracted data, and assessed risk of bias using Cochrane's RoB 1 tool. We resolved disagreements by discussion, or by consulting a third review author when necessary. We assessed the certainty of evidence using GRADE. MAIN RESULTS: We included five RCTs with 1228 participants and 1228 ACs. All included studies had high risk of bias in one or more domains. We present the following four comparisons, with the remaining comparisons reported in the main review. Standard polyurethane (SPU) plus tissue adhesive (TA) compared with SPU: we are very uncertain whether use of SPU plus TA impacts rates of AC failure (risk ratio (RR) 0.44, 95% confidence interval (CI) 0.20 to 0.98; I² = 0%; 2 studies, 165 participants; very low-certainty evidence). Neither study (165 participants) reported catheter-related bloodstream infections (CRBSI), thus we are very uncertain whether SPU plus TA impacts on the incidence of CRBSI (very low-certainty evidence). It is very uncertain whether use of SPU plus TA impacts AC dislodgement risk (RR 0.54, 95% CI 0.03 to 9.62; I² = 44%; 2 studies, 165 participants; very low-certainty evidence). We are very uncertain whether use of SPU plus TA impacts AC occlusion rates (RR 1.20, 95% CI 0.37 to 3.91; I² = 3%; 2 studies, 165 participants; very low-certainty evidence). We are very uncertain whether use of SPU plus TA impacts rates of adverse events with few reported events across groups (RR 0.89, 95% CI 0.09 to 8.33; I² = 0%; 2 studies, 165 participants; very low-certainty evidence). Bordered polyurethane (BPU) compared to SPU: we are very uncertain whether use of BPU impacts rates of AC failure (RR 0.67, 95% CI 0.21 to 2.13; 1 study, 60 participants; very low-certainty evidence). BPU may make little or no difference to CRBSI compared to SPU (RR 3.05, 95% CI 0.12 to 74.45; I² = not applicable as 1 study (60 participants) reported 0 events; 2 studies, 572 participants; low-certainty evidence). BPU may make little or no difference to the risk of AC dislodgement compared with SPU (RR 0.75, 95% CI 0.17 to 3.22; I² = 0%; 2 studies, 572 participants; low-certainty evidence). BPU may make little or no difference to occlusion risk compared with SPU (RR 0.80, 95% CI 0.60 to 1.07; I² = 0%; 2 studies, 572 participants; low-certainty evidence). It is very uncertain whether BPU impacts on the risk of adverse events compared with SPU (RR 0.33, 95% CI 0.01 to 7.87; 1 study, 60 participants; very low-certainty evidence). SPU plus sutureless securement devices (SSD) compared to SPU: we are very uncertain whether SPU plus SSD impacts risk of AC failure compared with SPU (RR 0.78, 95% CI 0.40 to 1.52; I² = 0%; 2 studies, 157 participants; very low-certainty evidence). We are very uncertain if SPU plus SSD impacts CRBSI incidence rate with no events in both groups (2 studies, 157 participants; very low-certainty evidence). It is very uncertain whether SPU plus SSD impacts risk of dislodgement (RR 0.14, 95% CI 0.01 to 2.57; I² = not applicable as 1 study (96 participants) reported 0 events; 2 studies, 157 participants; very low-certainty evidence). It is very uncertain whether SPU plus SSD impacts risk of AC occlusion (RR 1.94, 95% CI 0.50 to 7.48; I² = 38%; 2 studies, 157 participants; very low-certainty evidence). We are very uncertain whether SPU plus SSD impacts on the risk of adverse events (RR 1.94, 95% CI 0.19 to 20.24; I² = not applicable as 1 study (96 participants) reported 0 events; 2 studies, 157 participants; very low-certainty evidence). Integrated securement dressings compared to SPU: integrated securement dressings may result in little or no difference in risk of AC failure compared with SPU (RR 1.96, 95% CI 0.80 to 4.84; 1 study, 105 participants; low-certainty evidence); may result in little or no difference in CRBSI incidence with no events reported (1 study, 105 participants; low-certainty evidence); may result in little or no difference in the risk of dislodgement (RR 0.33, 95% CI 0.04 to 3.04; 1 study, 105 participants; low-certainty evidence), may result in little or no difference in occlusion rates with no events reported (1 study, 105 participants; low-certainty evidence), and may result in little or no difference in the risk of adverse events (RR 0.35, 95% CI 0.01 to 8.45; 1 study, 105 participants; low-certainty evidence). AUTHORS' CONCLUSIONS: There is currently limited rigorous RCT evidence available about the relative clinical effectiveness of AC dressing and securement products. Limitations of current evidence include small sample size, infrequent events, and heterogeneous outcome measurements. We found no clear difference in the incidence of AC failure, CRBSI, or adverse events across AC dressing or securement products including SPU, BPU, SSD, TA, and integrated securement products. The limitations of current evidence means further rigorous RCTs are needed to reduce uncertainty around the use of dressing and securement devices for ACs.


Subject(s)
Bandages , Catheter-Related Infections , Catheterization, Peripheral , Polyurethanes , Randomized Controlled Trials as Topic , Humans , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/instrumentation , Catheter-Related Infections/prevention & control , Bias , Equipment Failure
3.
Cochrane Database Syst Rev ; 6: CD013366, 2024 Jun 28.
Article in English | MEDLINE | ID: mdl-38940297

ABSTRACT

BACKGROUND: Peripherally inserted central catheters (PICCs) facilitate diagnostic and therapeutic interventions in health care. PICCs can fail due to infective and non-infective complications, which PICC materials and design may contribute to, leading to negative sequelae for patients and healthcare systems. OBJECTIVES: To assess the effectiveness of PICC material and design in reducing catheter failure and complications. SEARCH METHODS: The University of Queensland and Cochrane Vascular Information Specialist searched the Cochrane Vascular Specialised Register, CENTRAL, MEDLINE, Embase, and CINAHL databases and the WHO ICTRP and ClinicalTrials.gov trials registers to 16 May 2023. We aimed to identify other potentially eligible trials or ancillary publications by searching the reference lists of retrieved included trials, as well as relevant systematic reviews, meta-analyses, and health technology assessment reports. We contacted experts in the field to ascertain additional relevant information. SELECTION CRITERIA: We included randomised controlled trials (RCTs) evaluating PICC design and materials. DATA COLLECTION AND ANALYSIS: We used standard Cochrane methods. Our primary outcomes were venous thromboembolism (VTE), PICC-associated bloodstream infection (BSI), occlusion, and all-cause mortality. Secondary outcomes were catheter failure, PICC-related BSI, catheter breakage, PICC dwell time, and safety endpoints. We assessed the certainty of evidence using GRADE. MAIN RESULTS: We included 12 RCTs involving approximately 2913 participants (one multi-arm study). All studies except one had a high risk of bias in one or more risk of bias domain. Integrated valve technology compared to no valve technology for peripherally inserted central catheter design Integrated valve technology may make little or no difference to VTE risk when compared with PICCs with no valve (risk ratio (RR) 0.71, 95% confidence interval (CI) 0.19 to 2.63; I² = 0%; 3 studies; 437 participants; low certainty evidence). We are uncertain whether integrated valve technology reduces PICC-associated BSI risk, as the certainty of the evidence is very low (RR 0.20, 95% CI 0.01 to 4.00; I² = not applicable; 2 studies (no events in 1 study); 257 participants). Integrated valve technology may make little or no difference to occlusion risk when compared with PICCs with no valve (RR 0.86, 95% CI 0.53 to 1.38; I² = 0%; 5 studies; 900 participants; low certainty evidence). We are uncertain whether use of integrated valve technology reduces all-cause mortality risk, as the certainty of evidence is very low (RR 0.85, 95% CI 0.44 to 1.64; I² = 0%; 2 studies; 473 participants). Integrated valve technology may make little or no difference to catheter failure risk when compared with PICCs with no valve (RR 0.80, 95% CI 0.62 to 1.03; I² = 0%; 4 studies; 720 participants; low certainty evidence). We are uncertain whether integrated-valve technology reduces PICC-related BSI risk (RR 0.51, 95% CI 0.19 to 1.32; I² = not applicable; 2 studies (no events in 1 study); 542 participants) or catheter breakage, as the certainty of evidence is very low (RR 1.05, 95% CI 0.22 to 5.06; I² = 20%; 4 studies; 799 participants). Anti-thrombogenic surface modification compared to no anti-thrombogenic surface modification for peripherally inserted central catheter design We are uncertain whether use of anti-thrombogenic surface modified catheters reduces risk of VTE (RR 0.67, 95% CI 0.13 to 3.54; I² = 15%; 2 studies; 257 participants) or PICC-associated BSI, as the certainty of evidence is very low (RR 0.20, 95% CI 0.01 to 4.00; I² = not applicable; 2 studies (no events in 1 study); 257 participants). We are uncertain whether use of anti-thrombogenic surface modified catheters reduces occlusion (RR 0.69, 95% CI 0.04 to 11.22; I² = 70%; 2 studies; 257 participants) or all-cause mortality risk, as the certainty of evidence is very low (RR 0.49, 95% CI 0.05 to 5.26; I² = not applicable; 1 study; 111 participants). Use of anti-thrombogenic surface modified catheters may make little or no difference to risk of catheter failure (RR 0.76, 95% CI 0.37 to 1.54; I² = 46%; 2 studies; 257 participants; low certainty evidence). No PICC-related BSIs were reported in one study (111 participants). As such, we are uncertain whether use of anti-thrombogenic surface modified catheters reduces PICC-related BSI risk (RR not estimable; I² = not applicable; very low certainty evidence). We are uncertain whether use of anti-thrombogenic surface modified catheters reduces the risk of catheter breakage, as the certainty of evidence is very low (RR 0.15, 95% CI 0.01 to 2.79; I² = not applicable; 2 studies (no events in 1 study); 257 participants). Antimicrobial impregnation compared to non-antimicrobial impregnation for peripherally inserted central catheter design We are uncertain whether use of antimicrobial-impregnated catheters reduces VTE risk (RR 0.54, 95% CI 0.05 to 5.88; I² = not applicable; 1 study; 167 participants) or PICC-associated BSI risk, as the certainty of evidence is very low (RR 2.17, 95% CI 0.20 to 23.53; I² = not applicable; 1 study; 167 participants). Antimicrobial-impregnated catheters probably make little or no difference to occlusion risk (RR 1.00, 95% CI 0.57 to 1.74; I² = 0%; 2 studies; 1025 participants; moderate certainty evidence) or all-cause mortality (RR 1.12, 95% CI 0.71 to 1.75; I² = 0%; 2 studies; 1082 participants; moderate certainty evidence). Antimicrobial-impregnated catheters may make little or no difference to risk of catheter failure (RR 1.04, 95% CI 0.82 to 1.30; I² = not applicable; 1 study; 221 participants; low certainty evidence). Antimicrobial-impregnated catheters probably make little or no difference to PICC-related BSI risk (RR 1.05, 95% CI 0.71 to 1.55; I² = not applicable; 2 studies (no events in 1 study); 1082 participants; moderate certainty evidence). Antimicrobial-impregnated catheters may make little or no difference to risk of catheter breakage (RR 0.86, 95% CI 0.19 to 3.83; I² = not applicable; 1 study; 804 participants; low certainty evidence). AUTHORS' CONCLUSIONS: There is limited high-quality RCT evidence available to inform clinician decision-making for PICC materials and design. Limitations of the current evidence include small sample sizes, infrequent events, and risk of bias. There may be little to no difference in the risk of VTE, PICC-associated BSI, occlusion, or mortality across PICC materials and designs. Further rigorous RCTs are needed to reduce uncertainty.


Subject(s)
Catheter-Related Infections , Catheterization, Peripheral , Equipment Design , Equipment Failure , Randomized Controlled Trials as Topic , Venous Thromboembolism , Humans , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/instrumentation , Catheter-Related Infections/prevention & control , Venous Thromboembolism/prevention & control , Venous Thromboembolism/etiology , Catheter Obstruction , Central Venous Catheters/adverse effects , Cause of Death , Bias , Catheterization, Central Venous/adverse effects , Catheterization, Central Venous/instrumentation , Bacteremia/prevention & control , Bacteremia/etiology
4.
Curr Opin Anaesthesiol ; 37(4): 400-405, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-38841917

ABSTRACT

PURPOSE OF REVIEW: This review summarizes the latest findings and recommendations about the characteristics, indications and use of peripheral and central long-term venous access devices.The various complications inherent in these devices are becoming better known, and their contributing factors determined, which could make it possible to reduce their incidence. RECENT FINDINGS: Some measures are integrated into recommendations for good practice, such as appropriate selection of devices, the preferential use of the thinnest catheters, and cyanoacrylate glue and dressings impregnated with chlorhexidine. SUMMARY: Improving understanding of the phenomena leading to infectious and thrombotic complications, as well as better knowing the differences between intravenous devices and their respective indications, should lead to improvement of in-hospital and out-of-hospital care.


Subject(s)
Catheterization, Peripheral , Humans , Catheterization, Peripheral/instrumentation , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/methods , Catheterization, Central Venous/instrumentation , Catheterization, Central Venous/methods , Catheterization, Central Venous/adverse effects , Catheter-Related Infections/prevention & control , Catheter-Related Infections/etiology , Catheters, Indwelling/adverse effects , Central Venous Catheters/adverse effects
5.
Lancet ; 397(10283): 1447-1458, 2021 04 17.
Article in English | MEDLINE | ID: mdl-33865494

ABSTRACT

BACKGROUND: The optimal duration of infusion set use to prevent life-threatening catheter-related bloodstream infection (CRBSI) is unclear. We aimed to compare the effectiveness and costs of 7-day (intervention) versus 4-day (control) infusion set replacement to prevent CRBSI in patients with central venous access devices (tunnelled cuffed, non-tunnelled, peripherally inserted, and totally implanted) and peripheral arterial catheters. METHODS: We did a randomised, controlled, assessor-masked trial at ten Australian hospitals. Our hypothesis was CRBSI equivalence for central venous access devices and non-inferiority for peripheral arterial catheters (both 2% margin). Adults and children with expected greater than 24 h central venous access device-peripheral arterial catheter use were randomly assigned (1:1; stratified by hospital, catheter type, and intensive care unit or ward) by a centralised, web-based service (concealed before allocation) to infusion set replacement every 7 days, or 4 days. This included crystalloids, non-lipid parenteral nutrition, and medication infusions. Patients and clinicians were not masked, but the primary outcome (CRBSI) was adjudicated by masked infectious diseases physicians. The analysis was modified intention to treat (mITT). This study is registered with the Australian New Zealand Clinical Trials Registry ACTRN12610000505000 and is complete. FINDINGS: Between May 30, 2011, and Dec, 9, 2016, from 6007 patients assessed, we assigned 2944 patients to 7-day (n=1463) or 4-day (n=1481) infusion set replacement, with 2941 in the mITT analysis. For central venous access devices, 20 (1·78%) of 1124 patients (7-day group) and 16 (1·46%) of 1097 patients (4-day group) had CRBSI (absolute risk difference [ARD] 0·32%, 95% CI -0·73 to 1·37). For peripheral arterial catheters, one (0·28%) of 357 patients in the 7-day group and none of 363 patients in the 4-day group had CRBSI (ARD 0·28%, -0·27% to 0·83%). There were no treatment-related adverse events. INTERPRETATION: Infusion set use can be safely extended to 7 days with resultant cost and workload reductions. FUNDING: Australian National Health and Medical Research Council.


Subject(s)
Catheter-Related Infections/etiology , Catheterization, Central Venous/instrumentation , Catheterization, Peripheral/instrumentation , Aged , Australia , Catheter-Related Infections/epidemiology , Catheter-Related Infections/prevention & control , Catheterization, Central Venous/adverse effects , Catheterization, Central Venous/economics , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/economics , Child , Child, Preschool , Device Removal/economics , Equipment Contamination/statistics & numerical data , Female , Humans , Infant , Male , Middle Aged
6.
Hepatology ; 74(4): 2074-2084, 2021 10.
Article in English | MEDLINE | ID: mdl-33445218

ABSTRACT

BACKGROUND AND AIMS: The optimal treatment for gastric varices (GVs) is a topic that remains open for study. This study compared the efficacy and safety of endoscopic cyanoacrylate injection and balloon-occluded retrograde transvenous obliteration (BRTO) to prevent rebleeding in patients with cirrhosis and GVs after primary hemostasis. APPROACH AND RESULTS: Patients with cirrhosis and history of bleeding from gastroesophageal varices type 2 or isolated gastric varices type 1 were randomized to cyanoacrylate injection (n = 32) or BRTO treatment (n = 32). Primary outcomes were gastric variceal rebleeding or all-cause rebleeding. Patient characteristics were well balanced between two groups. Mean follow-up time was 27.1 ± 12.0 months in a cyanoacrylate injection group and 27.6 ± 14.3 months in a BRTO group. Probability of gastric variceal rebleeding was higher in the cyanoacrylate injection group than in the BRTO group (P = 0.024). Probability of remaining free of all-cause rebleeding at 1 and 2 years for cyanoacrylate injection versus BRTO was 77% versus 96.3% and 65.2% versus 92.6% (P = 0.004). Survival rates, frequency of complications, and worsening of esophageal varices were similar in both groups. BRTO resulted in fewer hospitalizations, inpatient stays, and lower medical costs. CONCLUSIONS: BRTO is more effective than cyanoacrylate injection in preventing rebleeding from GVs, with similar frequencies of complications and mortalities.


Subject(s)
Balloon Occlusion , Catheterization, Peripheral , Cyanoacrylates/administration & dosage , Gastrointestinal Hemorrhage , Hemostasis, Endoscopic , Liver Cirrhosis/complications , Balloon Occlusion/adverse effects , Balloon Occlusion/methods , Balloon Occlusion/statistics & numerical data , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/instrumentation , Catheterization, Peripheral/methods , Comparative Effectiveness Research , Esophageal and Gastric Varices/etiology , Esophageal and Gastric Varices/therapy , Female , Gastrointestinal Hemorrhage/etiology , Gastrointestinal Hemorrhage/mortality , Gastrointestinal Hemorrhage/prevention & control , Gastrointestinal Hemorrhage/therapy , Hemostasis, Endoscopic/adverse effects , Hemostasis, Endoscopic/methods , Hemostasis, Endoscopic/statistics & numerical data , Hemostatics/administration & dosage , Humans , Male , Middle Aged , Outcome and Process Assessment, Health Care , Recurrence , Survival Analysis , Tissue Adhesives/administration & dosage
7.
J Vasc Surg ; 75(1): 177-185.e1, 2022 01.
Article in English | MEDLINE | ID: mdl-34302937

ABSTRACT

OBJECTIVE/BACKGROUND: Retrograde recanalizations gained increasing recognition in complex arterial occlusive disease. Re-entry devices are a well-described adjunct for antegrade recanalizations. We present our experience with retrograde, infrainguinal recanalizations using the Outback re-entry catheter in challenging chronic total occlusions. METHODS: We report data from a retrospective multicenter registry in complex retrograde recanalizations. Eligibility criteria included retrograde infrainguinal use of the Outback re-entry catheter where both conventional antegrade and retrograde recanalizations had been unsuccessful. Procedural outcomes included technical success (defined as successful wire passage and delivery of adjunctive therapy with <30% residual stenosis), safety (periprocedural complications, eg, bleeding, vessel injury, or occlusion of the artery at the re-entry site, and distal embolizations), and clinical outcome (amputation-free survival and freedom from clinically driven target lesion revascularization [cd-TLR]). RESULTS: Forty-five consecutive patients underwent retrograde, infrainguinal recanalization attempts with the Outback re-entry catheter between February 2015 and August 2020. Thirty (67%) patients had a history of open vascular surgery in the index limb. In four patients, recanalizations were even more challenging due to previous surgical removal and/or ligation of the proximal segment of the superficial femoral artery. The retrograde access site of the Outback catheter was the femoropopliteal segment in 31 (69%) patients and crural vessels in 14 (31%) patients. The re-entry target sites were as follows: common femoral artery in 31 (69%) patients, superficial femoral artery in 9 (20%) patients, popliteal artery in 1 patient, and below-the-knee arteries in 2 patients. In four patients, the needle of the re-entry device was targeted to an inflated balloon, inserted via the antegrade route. The Outback re-entry catheter was placed via a 6-French sheath in 19 (42%) cases and sheathless in 26 (58%) cases. Technical success was achieved in 41 (91%) patients There were two instances of distal embolizations and three bleeding episodes. Amputation-free survival was 100% at 30 days, and after 12 months, freedom from cd-TLR was 95% at 30 days and 75% at 12 months of follow-up. Female sex was an independent predictor for cd-TLR at 12 months of follow-up. CONCLUSIONS: Retrograde use of the Outback re-entry catheter in infrainguinal chronic total occlusions provides an effective and safe endovascular adjunct, when conventional antegrade and retrograde recanalization attempts have failed.


Subject(s)
Angioplasty/instrumentation , Arterial Occlusive Diseases/surgery , Catheterization, Peripheral/instrumentation , Postoperative Complications/epidemiology , Aged , Aged, 80 and over , Angioplasty/adverse effects , Angioplasty/methods , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/methods , Catheters/adverse effects , Female , Femoral Artery/surgery , Follow-Up Studies , Humans , Male , Middle Aged , Popliteal Artery/surgery , Postoperative Complications/etiology , Retrospective Studies , Stents/adverse effects , Treatment Outcome
8.
BMC Cardiovasc Disord ; 22(1): 63, 2022 02 20.
Article in English | MEDLINE | ID: mdl-35184743

ABSTRACT

BACKGROUND: Primary malignant tumors of the heart are rare. Although preoperative histological diagnosis is difficult, it has paramount value in therapeutic strategy development and prognostic estimation. Herein, we reported 2 cases of intracardiac tumors. CASES PRESENTATION: Both patients presented to the hospital with heart-related symptoms. Echocardiography showed massive masses in the atrium and positron emission tomography-computed tomography (PET/CT) revealed hypermetabolism and invasiveness. One patient cannot take surgery due to extensive metastasis and poor condition. The other patient was primarily diagnosed with lymphoma, and surgery was not recommended. They successfully underwent intravenous atrial biopsy, and histological samples confirmed intimal sarcoma and diffuse large B cell lymphoma. Based on immunohistochemical and molecular assessments, targeted chemotherapy was administered, resulting in clinical and imaging remission at discharge. CONCLUSIONS: Percutaneous intravenous catheter biopsy as a safe invasive test provides an accurate pathological diagnosis after imaging evaluation, and offers a therapeutic direction. Nonmalignant masses and some chemo-radiosensitive malignant tumors in the atrium could have good prognosis after targeted therapy.


Subject(s)
Catheterization, Peripheral/instrumentation , Heart Atria/pathology , Heart Neoplasms/pathology , Lymphoma, Large B-Cell, Diffuse/pathology , Sarcoma/pathology , Surgical Instruments , Aged , Antineoplastic Combined Chemotherapy Protocols/therapeutic use , Biopsy , Female , Heart Atria/diagnostic imaging , Heart Atria/drug effects , Heart Neoplasms/diagnostic imaging , Heart Neoplasms/drug therapy , Humans , Lymphoma, Large B-Cell, Diffuse/diagnostic imaging , Lymphoma, Large B-Cell, Diffuse/drug therapy , Magnetic Resonance Imaging , Male , Middle Aged , Molecular Targeted Therapy , Neoplasm Staging , Positron Emission Tomography Computed Tomography , Sarcoma/diagnostic imaging , Sarcoma/drug therapy , Treatment Outcome
9.
Ann Vasc Surg ; 78: 190-196, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34464729

ABSTRACT

BACKGROUND: A total percutaneous approach for management of aortic pathologies with endovascular grafts requires the use of large size delivery-systems. The diameter of these delivery systems usually exceeds the recommended sizes for most of the currently available percutaneous closure devices. A safe, effective and simple vascular access site closure device is desirable for success for percutaneous procedures for aortic pathologies. Hence, we aim to study safety and effectiveness of the use of a single suture based vascular access closure device (ProGlide) using a technique involving serial up and downsizing of the sheath size to achieve access site hemostasis in patients undergoing endovascular graft placement using femoral artery approach. MATERIALS AND METHODS: We studied all consecutive patients who underwent endovascular grafting from January 2018 to December 2019. It is a retrospective observational study comparing procedural and short-term outcomes between single ProGlide use and surgical cut-down for femoral access site closure. We excluded patients with femoral artery minimal luminal diameter less than 5 mm, the presence of an aneurysm of the femoral artery, ≥180 degrees of calcium present at femoral/ external iliac artery and history of any vascular closure device use in the last six months. RESULTS: We included 30 patients in single ProGlide group and 30 patients in the surgical cut-down group. One-third of the procedures were urgent procedures in the single Proglide group. Single ProGlide was successful in 93.34% patients and failure (6.66%) was seen due to hematoma and pseudoaneurysm in one patient each detected before discharge. The primary end-point defined by the success of procedure did not differ between the two groups. There were higher complications in the surgical group till 30 days as evidenced by infection, hematoma and neuronal injury. The secondary end-point, defined by the composite of complication events after discharge till 30 days was significantly higher in the surgical group (P-0.005) CONCLUSION: In patients with suitable femoral artery anatomy who undergo endovascular graft placement, effective hemostasis can be achieved safely using up and downsizing of the sheath with a single suture-based technique (Proglide). The results of the study could be considered hypothesis generating and needs to be confirmed in a randomized controlled trial before being adopted in clinical practice.


Subject(s)
Aortic Diseases/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Catheterization, Peripheral/instrumentation , Endovascular Procedures/instrumentation , Hemorrhage/prevention & control , Hemostatic Techniques/instrumentation , Vascular Access Devices , Vascular Closure Devices , Aged , Aged, 80 and over , Aortic Diseases/diagnostic imaging , Blood Vessel Prosthesis Implantation/adverse effects , Catheterization, Peripheral/adverse effects , Endovascular Procedures/adverse effects , Equipment Design , Female , Femoral Artery , Hemorrhage/etiology , Hemostatic Techniques/adverse effects , Humans , Male , Punctures , Retrospective Studies , Time Factors , Treatment Outcome
10.
J Vasc Surg ; 74(3): 746-755, 2021 09.
Article in English | MEDLINE | ID: mdl-33592298

ABSTRACT

OBJECTIVE: Our aim was to evaluate the efficacy and safety outcomes of the Pioneer Plus catheter (Philips, San Diego, Calif) and report the in-hospital and 30-day outcomes of lower extremity chronic total occlusion (CTO) interventions assisted by the Pioneer Plus catheter. In addition, we explored the factors associated with procedural success. METHODS: We conducted a retrospective review of 135 consecutive procedures in 116 patients from July 2011 to September 2018 performed by eight operators with various levels of experience at a high-volume center where the Pioneer Plus catheter was used for lower extremity CTO. The patient demographics, preprocedural symptoms, preprocedural testing results, procedural setting, and angiography findings were abstracted. The outcomes were divided into device-related and procedure-related outcomes. Device-related efficacy outcome included procedural success. Device-related safety outcomes included device-related complications. Procedure-related outcomes included procedure-related complications, 30-day major adverse cardiovascular events, and 30-day major adverse limb events. We conducted univariate comparisons of the provider, patient, and procedural characteristics stratified by procedural success. RESULTS: Procedural success was observed in 118 procedures overall (87.4%), and success rates ≤95.8% were observed for operators with an experience level of >25 devices deployed. No device-related complications, such as pseudoaneurysm formation, vessel perforation, or arteriovenous fistula formation, were observed. The Pioneer Plus catheter was mostly often used for CTO in the superficial femoral and popliteal arteries. Overall, the procedure-related complications included access site hematoma (5.2%), major bleeding (0.7%), pseudoaneurysm formation (0.7%), distal embolization (1.5%), and acute arterial thrombosis (1.5%). The 30-day major adverse limb events included index limb unplanned amputation (0.7%), index limb reintervention (4.4%), and index limb acute limb ischemia (0.7%) and occurred in 5.9% of the procedures. The only factor associated with procedural success was operator experience (P < .0001). CONCLUSIONS: The results from the present study have shown that Pioneer Plus catheter use is safe and effective when used to cross lower extremity CTO. However, further investigation is needed to identify patient- and provider-level factors to optimize patient outcomes.


Subject(s)
Catheterization, Peripheral/instrumentation , Endovascular Procedures/instrumentation , Lower Extremity/blood supply , Peripheral Arterial Disease/therapy , Ultrasonography, Interventional/instrumentation , Vascular Access Devices , Aged , Catheterization, Peripheral/adverse effects , Chronic Disease , Endovascular Procedures/adverse effects , Equipment Design , Female , Humans , Male , Middle Aged , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/physiopathology , Retrospective Studies , Time Factors , Treatment Outcome , Ultrasonography, Interventional/adverse effects , Vascular Patency
11.
Am J Nephrol ; 52(6): 479-486, 2021.
Article in English | MEDLINE | ID: mdl-34111865

ABSTRACT

INTRODUCTION: Successful cannulation of an arteriovenous fistula (AVF) is important in patients starting hemodialysis (HD). Metal needles have been used for decades, but the usefulness of plastic cannulae has recently been demonstrated as a new technique. METHODS: This was a prospective, randomized, open-label study of incident HD patients. Eligible patients were randomized into 2 groups in a 1:1 ratio (n = 45/group). Maturation of the AVF was confirmed using Doppler ultrasound prior to first needling, and 2 well-trained nurses implemented the AVF cannulation. The primary endpoint was the initial cannulation failure rate, defined as the failure of successful completion of 3 consecutive dialysis sessions. The secondary endpoints were time for hemostasis at the end of HD, degree of patients' pain, degree of cannulation difficulty felt by the nursing staffs, and achieving optimal HD adequacy. RESULTS: The mean elapsed time from AVF creation to the first cannulation was 48.1 ± 16.7 days. A total of 17 cases of cannulation failure occurred, and the failure risk tended to be higher in the metal needle group than the plastic cannula group (hazard ratio 2.6, 95% confidence interval 0.95-7.41) after adjusting for age, gender, comorbidities, and AVF location. The overall incidence of vessel injury was higher and time for hemostasis was significantly longer in the metal group than the plastic group. The use of plastic cannula was associated with a better HD adequacy compared to a metal needle. However, the patients' pain score (p = 0.004) and nursing staff's cannulation difficulty score (p = 0.084) were higher in the plastic group, emphasizing the great importance of practice using plastic cannulae. CONCLUSION: The vascular outcomes of plastic cannulae were much favorable compared to metal needles in incident HD patients. The use of plastic cannulae could be a new and innovative way to improve the quality of dialysis.


Subject(s)
Cannula , Catheterization, Peripheral/instrumentation , Needles , Renal Dialysis/instrumentation , Aged , Arteriovenous Shunt, Surgical , Blood Vessels/injuries , Cannula/adverse effects , Female , Hemostasis , Humans , Male , Metals , Middle Aged , Needles/adverse effects , Pain, Procedural/etiology , Plastics , Prospective Studies , Time Factors
12.
BMC Cardiovasc Disord ; 21(1): 388, 2021 08 10.
Article in English | MEDLINE | ID: mdl-34376149

ABSTRACT

BACKGROUND: Catheter-based renal denervation (RDN) has been introduced to treat resistant hypertension. Although the technology of RDN has been largely improved, denervation of tortuous renal arteries remains challenging. CASE PRESENTATION: This is a case report of a 49-year-old man with drug resistant hypertension. The patient was selected for RDN after ruling out possible causes of secondary hypertension. Computed tomography angiography showed a highly tortuous left renal artery. An Iberis multielectrode ablation catheter failed to reach the target vessel with a regular guiding catheter. A 5-French extension catheter was introduced into the proximal segment of the main left renal artery to provide extra support force, which enabled successful ablation of the highly tortuous left renal artery. His ambulatory blood pressure was significantly decreased at 1 month follow-up. CONCLUSIONS: It is feasible and effective to use a guide extension catheter for denervation of highly tortuous renal arteries. The present study provides a useful method to ablate tortuous and angled renal arteries and branches.


Subject(s)
Catheter Ablation/instrumentation , Essential Hypertension/surgery , Renal Artery/abnormalities , Renal Artery/innervation , Sympathectomy/instrumentation , Catheterization, Peripheral/instrumentation , Computed Tomography Angiography , Drug Resistance , Essential Hypertension/drug therapy , Humans , Male , Middle Aged , Renal Artery/diagnostic imaging , Sympathectomy/methods
13.
BMC Cardiovasc Disord ; 21(1): 46, 2021 01 22.
Article in English | MEDLINE | ID: mdl-33482724

ABSTRACT

BACKGROUND: The broken guide wire could get stuck anywhere during coronary artery angiography, but the broken guide wire in the brachial artery is extremely rare. CASE PRESENTATION: In this report, we describe our experience with a case of off-pump coronary artery bypass (OPCABG) concomitant with the retrieval of a broken guide wire stuck in the brachial artery: a 56-year-old male patient was referred to our hospital because of tri-vessel disease and a broken guide wire stuck in the right brachial artery. He received OPCABG concomitant with the retrieval of the broken guide wire stuck in the brachial artery under general anesthesia. The patient was discharged uneventfully, and 12 months follow-up showed an excellent surgical outcome. CONCLUSION: Open surgery is an effective means for treating patients with a guide wire stuck in the brachial artery during percutaneous coronary intervention.


Subject(s)
Brachial Artery/surgery , Catheterization, Peripheral/instrumentation , Coronary Artery Bypass, Off-Pump , Coronary Artery Disease/surgery , Device Removal , Foreign Bodies/surgery , Vascular Access Devices , Brachial Artery/diagnostic imaging , Catheterization, Peripheral/adverse effects , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Equipment Failure , Foreign Bodies/diagnostic imaging , Humans , Male , Middle Aged , Treatment Outcome
14.
J Thromb Thrombolysis ; 51(3): 757-766, 2021 Apr.
Article in English | MEDLINE | ID: mdl-32666428

ABSTRACT

The recent adjunctive catheter-directed thrombolysis (ATTRACT) trial rose a controversy about the treatment effect of catheter-directed thrombolysis (CDT) in deep venous thrombosis (DVT). In fact, most studies including the ATTRACT trial did not perform subgroup analysis of catheterization approaches. Different approaches would confound the conclusions. Therefore, a single-center retrospective analysis was performed to compare the differences between the antegrade (AGA) and retrograde (RGA) approaches. Total 217 DVT patients treated with CDT were enrolled from January 2010 to December 2017, with mean age of 55.3 years (67 received antegrade approach, 150 received retrograde approach). The clot burden reduction by segment was evaluated. The mean access establishment time and thrombolytic time were compared. The patency of the iliofemoral vein at 6 months was evaluated. The rate of PTS, quality of life and venous insufficiency were assessed at 1 year. AGA group showed better thrombolytic effect in popliteal and femoral vein than RGA group. The rate of iliofemoral clot burden reduction in RGA group was mostly at Grade II, while most were at Grade III in AGA group. The retrograde approach showed better thrombolysis effect in iliofemoral DVT than popliteal to iliac DVT. The RGA group reported longer mean access establishment time (5.4 ± 1.8 vs 27.0 ± 7.5 min, p < 0.001) and thrombolytic time (6.9 ± 1.5 days vs 6.8 ± 1.5 days, p = 0.586). At 6 months, RGA group had a lower rate of femoral vein patency (52.0% vs 89.6%, p < 0.001) and a higher rate of venous insufficiency (52.0% vs 29.9%, p < 0.001), compared with AGA group. Although there was no difference in the rate of PTS, the RGA group showed higher Villalta scores in the free and mild PTS. The antegrade approach was preferably recommended over the retrograde approach for CDT treatment.


Subject(s)
Catheterization, Peripheral , Femoral Vein , Iliac Vein , Thrombolytic Therapy , Venous Insufficiency , Venous Thrombosis , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/instrumentation , Catheterization, Peripheral/methods , Duration of Therapy , Female , Femoral Vein/pathology , Femoral Vein/physiopathology , Humans , Iliac Vein/pathology , Iliac Vein/physiopathology , Male , Mechanical Thrombolysis/instrumentation , Mechanical Thrombolysis/methods , Middle Aged , Outcome and Process Assessment, Health Care , Thrombolytic Therapy/adverse effects , Thrombolytic Therapy/instrumentation , Thrombolytic Therapy/methods , Vascular Patency , Venous Insufficiency/diagnosis , Venous Insufficiency/etiology , Venous Insufficiency/prevention & control , Venous Thrombosis/diagnosis , Venous Thrombosis/physiopathology , Venous Thrombosis/therapy
15.
Ann Vasc Surg ; 73: 133-138, 2021 May.
Article in English | MEDLINE | ID: mdl-33493592

ABSTRACT

BACKGROUND: COVID-19, the syndrome caused by the novel SARS-CoV2, is associated with high rates of acute kidney injury requiring renal replacement therapy (RRT). It is well known that despite the ease of bedside insertion, the use of nontunneled dialysis catheters (NTDCs) is associated with increased complications compared to tunneled dialysis catheters (TDCs). Our objective was to develop a strategy for TDC placement at the bedside to provide effective dialysis access, conserve resources and decrease personnel exposure at our medical center in an epicenter of the COVID-19 pandemic. METHODS: A technique for bedside TDC insertion with ultrasound and plain radiographs in the intensive care unit was developed. Test or clinically COVID-19-positive patients requiring RRT were evaluated for bedside emergent NTDC or nonemergent TDC placement. Patients who underwent NTDC placement were monitored for ongoing RRT needs and were converted to TDC at the bedside after 3-5 days. We prospectively collected patient data focusing on complications and mortality. RESULTS: Of the 36 consultations for dialysis access in COVID-positive patients from March 19 through June 5, 2020, a total of 24 bedside TDCs were placed. Only one patient developed a complication, which was pneumothorax and cardiac tamponade during line placement. In-hospital mortality in the cohort was 63.9%. CONCLUSIONS: Bedside TDC placement has served to conserve resources, prevent complications with transport to and from the operating room, and decrease personnel exposure during the COVID-19 pandemic. This strategy warrants further consideration and could be used in critically ill patients regardless of COVID status.


Subject(s)
Acute Kidney Injury/therapy , COVID-19/complications , Catheterization, Peripheral/methods , Renal Replacement Therapy , Acute Kidney Injury/etiology , Aged , Catheterization, Peripheral/instrumentation , Catheters, Indwelling , Female , Humans , Male , Middle Aged , Ultrasonography, Interventional
16.
Ann Vasc Surg ; 71: 528-532, 2021 Feb.
Article in English | MEDLINE | ID: mdl-32950625

ABSTRACT

Aim of this paper is to describe a simple and helpful technique for challenging visceral vessel catheterization during complex aortic endovascular procedures. In demanding anatomies when standard visceral vessel cannulation maneuvers result ineffective, inflating a compliant balloon above the target arteries may allow easy and safe advancement of the introducer sheath inside selected vessel. This approach lowers the shear forces enhancing device pushability. The use of a compliant aortic balloon with the Ceiling technique is a useful, easy and reproducible endovascular option that can be adopted for challenging vessel catheterization during advanced endovascular procedures.


Subject(s)
Aortic Aneurysm/surgery , Blood Vessel Prosthesis Implantation , Catheterization, Peripheral , Endovascular Procedures , Viscera/blood supply , Aortic Aneurysm/diagnostic imaging , Blood Vessel Prosthesis Implantation/instrumentation , Catheterization, Peripheral/instrumentation , Endovascular Procedures/instrumentation , Humans , Treatment Outcome
17.
Ann Vasc Surg ; 74: 518.e7-518.e11, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33556519

ABSTRACT

Recanalization of chronic iliofemoral deep vein thrombosis is indicated to reduce symptoms and improve quality of life. However, recanalization is dependent on the ability to cross chronic obstructions. We present a case of chronically thrombosed inferior vena cava and common iliac veins that failed conventional crossing techniques but were successfully recanalized using the recently approved Upstream GoBack Crossing Catheter.


Subject(s)
Catheterization, Peripheral , Catheters , Iliac Vein/surgery , Vena Cava, Inferior/surgery , Venous Thrombosis/surgery , Adult , Catheterization, Peripheral/instrumentation , Catheterization, Peripheral/methods , Chronic Disease , Female , Humans , Phlebography , Vascular Surgical Procedures/methods , Venous Thrombosis/diagnostic imaging
18.
Ann Vasc Surg ; 77: 338-342, 2021 Nov.
Article in English | MEDLINE | ID: mdl-34464731

ABSTRACT

We developed a novel technique using an endovascular snare system to stabilize target vessel cannulation via transfemoral access during fenestrated and branched endovascular aortic aneurysm repair (FBEVAR) in patients with challenging target vessel anatomy. This technique uses a snare, an outer sheath, and an inner delivery sheath to facilitate target vessel cannulation and stenting during FBEVAR. With the outer sheath positioned in the lower end of the partially deployed aortic graft and the delivery sheath within, a large snare is advanced through the outer sheath and over the outside of the delivery sheath until it reaches the curved portion of the delivery sheath at the level of the target vessel. The snare is then tightened to provide stability and maintain proper curvature and alignment of the delivery sheath while the target vessel is selected and stented. Following successful passage, the snare is loosened and removed from the body via the outer sheath. This snare technique is a simple, effective, and inexpensive tool that can be used for difficult target vessel cannulation during FBEVAR.


Subject(s)
Aortic Aneurysm/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Catheterization, Peripheral/instrumentation , Endovascular Procedures/instrumentation , Femoral Artery , Stents , Vascular Access Devices , Aortic Aneurysm/diagnostic imaging , Blood Vessel Prosthesis Implantation/adverse effects , Catheterization, Peripheral/adverse effects , Endovascular Procedures/adverse effects , Femoral Artery/diagnostic imaging , Humans , Prosthesis Design , Treatment Outcome
19.
Ann Vasc Surg ; 75: 518-522, 2021 Aug.
Article in English | MEDLINE | ID: mdl-33823251

ABSTRACT

Branched endovascular aortic aneurysm repair (BEVAR) necessitates upper limb access (ULA) to facilitate the antegrade cannulation of downward directional branches and the placement of the bridging stent grafts. Various technical solutions to avoid ULA have been proposed and successfully applied in a limited number of cases. This can be necessary in specific clinical scenarios such as hostile aortic arch and descending thoracic aortic anatomy, or in the case of previous aortic arch and supra-aortic vessels surgery complicating the conventional approach with ULA in BEVAR. Taking inspiration from the prior description of a precursory technique, we report the application of our technique in BEVAR procedures, using standard introducer sheaths as a directional stable platform to facilitate an "All Femoral Access" (AFA) approach without the need for ULA, snaring or commercial steerable sheaths. Our concept is based on utilizing a wire loop to form a directional sheath (WILD sheath technique).


Subject(s)
Aortic Aneurysm/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Catheterization, Peripheral/instrumentation , Endovascular Procedures/instrumentation , Femoral Artery , Stents , Vascular Access Devices , Aged , Aortic Aneurysm/diagnostic imaging , Aortic Aneurysm/physiopathology , Blood Vessel Prosthesis Implantation/adverse effects , Catheterization, Peripheral/adverse effects , Endovascular Procedures/adverse effects , Female , Humans , Prosthesis Design , Punctures , Treatment Outcome
20.
Ann Vasc Surg ; 74: 258-263, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33549772

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation (TAVI) procedures have revolutionized the treatment of aortic stenosis. However, due to large sheaths, improperly deployed closure devices, and the comorbidities and challenges innate to this population, vascular access complications can be devastating. The objective of this study is to evaluate vascular access complications in one of the largest TAVI sites in North America. METHODS: This was a retrospective single center review between January 2014 and December 2018 of vascular access complications necessitating operative intervention by vascular surgery. Patient demographics and preoperative comorbidities were collected. Type of vascular access complication, types of repair, closure device used, and postoperative outcomes were analyzed. RESULTS: A total of 37 cases out of a total of 985 TAVI procedures were identified. TAVI was carried out in the operating suite (70%) or the catheterization lab (30%). Consults to vascular surgery were requested intraoperatively (60%), immediately postoperative (14%), later in the day of the TAVI (20%), and on postoperative day 1 (6%). The location of injury included common femoral artery (49%), superficial femoral artery (11%) and external iliac artery (41%), with some cases injuring multiple vessels. Closure devices were found in the subcutaneous tissue (26%), anterior wall (37%), posterior wall (11%), intra-arterial (11%), closing the anterior to the posterior wall (16%), and in the inguinal ligament (5%). Injuries included tears (11%), dissections (38%), and vessel rupture (19%). The majority of repairs were done primarily (64%), with patch (28%) and bypass (8%) less frequently. Four patients died perioperatively (11%), 2 from hemorrhage, 1 from cardiac arrest, and 1 from progressive respiratory disease. CONCLUSIONS: Access complications during TAVI procedures predispose complex patients to increased risk of morbidity and mortality. Careful patient selection, proper access techniques, and performing high risk patients in the operating suite with vascular surgery are fundamental in minimizing complications.


Subject(s)
Aortic Valve Stenosis/surgery , Catheterization, Peripheral/adverse effects , Hemostatic Techniques/adverse effects , Transcatheter Aortic Valve Replacement/adverse effects , Vascular Surgical Procedures , Vascular System Injuries/surgery , Aged , Aged, 80 and over , British Columbia , Catheterization, Peripheral/instrumentation , Clinical Decision-Making , Female , Heart Valve Prosthesis , Hemostatic Techniques/instrumentation , Humans , Male , Patient Selection , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/instrumentation , Treatment Outcome , Vascular Access Devices , Vascular Closure Devices , Vascular Surgical Procedures/adverse effects , Vascular System Injuries/diagnostic imaging , Vascular System Injuries/etiology
SELECTION OF CITATIONS
SEARCH DETAIL