Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 211
Filter
1.
J Vasc Surg ; 80(3): 937-945, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38462062

ABSTRACT

OBJECTIVE: Management of follow-up protocols after endovascular aortic repair (EVAR) varies significantly between centers and is not standardized according to sac regression. By designing an international expert-based Delphi consensus, the study aimed to create recommendations on follow-up after EVAR according to sac evolution. METHODS: Eight facilitators created appropriate statements regarding the study topic that were voted, using a 4-point Likert scale, by a selected panel of international experts using a three-round modified Delphi consensus process. Based on the experts' responses, only those statements reaching a grade A (full agreement ≥75%) or B (overall agreement ≥80% and full disagreement <5%) were included in the final document. RESULTS: One-hundred and seventy-four participants were included in the final analysis, and each voted the initial 29 statements related to the definition of sac regression (Q1-Q9), EVAR follow-up (Q10-Q14), and the assessment and role of sac regression during follow-up (Q15-Q29). At the end of the process, 2 statements (6.9%) were rejected, 9 statements (31%) received a grade B consensus strength, and 18 (62.1%) reached a grade A consensus strength. Of 27 final statements, 15 (55.6%) were classified as grade I, whereas 12 (44.4%) were classified as grade II. Experts agreed that sac regression should be considered an important indicator of EVAR success and always be assessed during follow-up after EVAR. CONCLUSIONS: Based on the elevated strength and high consistency of this international expert-based Delphi consensus, most of the statements might guide the current clinical management of follow-up after EVAR according to the sac regression. Future studies are needed to clarify debated issues.


Subject(s)
Aortic Aneurysm, Abdominal , Consensus , Delphi Technique , Endovascular Aneurysm Repair , Humans , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortography/standards , Computed Tomography Angiography/standards , Endovascular Aneurysm Repair/adverse effects , Endovascular Aneurysm Repair/standards , Predictive Value of Tests , Time Factors , Treatment Outcome
2.
Neurol Sci ; 45(8): 3901-3905, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38429470

ABSTRACT

OBJECTIVE: To investigate the clinical value of multi-slice spiral computed tomography angiography (MSCTA) in the diagnosis of intracranial aneurysms (ICA). METHODS: The imaging data of 68 patients suspected of having ICA who were examined in the Department of Radiology of the First Affiliated Hospital of Nanjing Medical University from March 2018 to March 2021 were retrospectively analyzed. MSCTA and digital subtraction angiography (DSA) were performed on each patient, and the MSCTA imaging analysis was compared with DSA. RESULTS: The accuracy of DSA in the diagnosis of ICA was 98.53% (67/68), while the accuracy of MSCTA in the diagnosis of ICA was 97.06% (66/68), with no significant difference in diagnostic accuracy (P > 0.05). There were no significant differences in the diameter of the aneurysm, the width of the aneurysm neck, or the location of the aneurysm in the comparison of the ICA image between DSA and MSCTA (P > 0.05). CONCLUSION: MSCTA offers high accuracy and has favorable clinical value in the diagnosis of ICA. It is worth popularizing as the recommended examination method in clinical practice.


Subject(s)
Angiography, Digital Subtraction , Computed Tomography Angiography , Intracranial Aneurysm , Humans , Intracranial Aneurysm/diagnostic imaging , Female , Middle Aged , Male , Retrospective Studies , Angiography, Digital Subtraction/methods , Computed Tomography Angiography/standards , Computed Tomography Angiography/methods , Adult , Aged , Cerebral Angiography/methods , Cerebral Angiography/standards , Tomography, Spiral Computed/methods
3.
Can Assoc Radiol J ; 75(3): 488-501, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38486401

ABSTRACT

Imaging the heart is one of the most technically challenging applications of Computed Tomography (CT) due to the presence of cardiac motion limiting optimal visualization of small structures such as the coronary arteries. Electrocardiographic gating during CT data acquisition facilitates motion free imaging of the coronary arteries. Since publishing the first version of the Canadian Association of Radiologists (CAR) cardiac CT guidelines, many technological advances in CT hardware and software have emerged necessitating an update. The goal of these cardiac CT practice guidelines is to present an overview of the current evidence supporting the use of cardiac CT in various clinical scenarios and to outline standards of practice for patient safety and quality of care when establishing a cardiac CT program in Canada.


Subject(s)
Computed Tomography Angiography , Coronary Angiography , Humans , Computed Tomography Angiography/methods , Computed Tomography Angiography/standards , Coronary Angiography/methods , Canada , Societies, Medical , Coronary Artery Disease/diagnostic imaging
4.
Ann Vasc Surg ; 79: 264-272, 2022 Feb.
Article in English | MEDLINE | ID: mdl-34656714

ABSTRACT

BACKGROUND: There is no consensus on the method of obtaining abdominal aortic aneurysm (AAA) maximum diameters based on computed tomographic angiography, and the reproducibility and accuracy of different methods have recently been debated due to advancements in imaging. This study compared the two most common methods based on orthogonal planes and centerline of flow to determine the discordances and accuracy amongst experiences readers. METHODS: The computed tomographic angiography max diameters of 148 AAAs were measured by three experienced observers, including a vascular surgeon, a radiologist and an imaging cardiologist. Observers used two different methods with standardized protocols: multiplanar reformations based on orthogonal planes, and a software using 3D aortic reconstructions to create centerline flow lumen providing diameters based on cross sections perpendicular to this lumen. Agreements and reliability of measurement methods were assessed by intra-class correlation coefficient and Bland - Altman analysis. Discordances between measurements of the methods and the original reported measurement, as well as outside hospitals were compared. RESULTS: The average age of the cohort was 75 years and aortic diameters ranged from 3.8 to 9.6 cm. For orthogonal readings, there were agreements within 3 mm between 86% and 92% of the time, while centerline - reading agreement was between 88% and 94%, which was not statistically significant. The intra-class correlation coefficient was high between method type and between readers. Within methods, agreement was between 0.96 and 0.97, while within - reader agreement measures was between 0.96 and 0.98. In comparison to the original and the outside hospital reports, 10% ≥ of the original and 20% ≥ of the outside hospital reported measurements were discordant between the readers. CONCLUSION: Maximal AAA measurements can have substantial variability leading to clinical significance and change in patient management and outcomes. Based on the results, orthogonal and centerline measurement methods have equally high agreements and concordance within 3 mm and low variations at a high volume center. However, when compared to the official read reports, there is high discordance rates that can significantly alter patient outcomes. A standardized method of measurement maximum diameter can reduce variations and discordances among different methods.


Subject(s)
Aorta, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortography/standards , Computed Tomography Angiography/standards , Aged , Aged, 80 and over , Dilatation, Pathologic , Female , Humans , Male , Middle Aged , Observer Variation , Predictive Value of Tests , Reproducibility of Results , Retrospective Studies
5.
J Oral Maxillofac Surg ; 80(8): 1434-1444, 2022 08.
Article in English | MEDLINE | ID: mdl-35461799

ABSTRACT

BACKGROUND: Virtual surgical planning (VSP), computer aided design/computer aided modeling, and 3-dimensional printing technology have been shown to improve surgical accuracy and efficiency in head and neck reconstruction. However, persisting criticism of the technology is that it does not adequately address the soft tissue-related aspects of reconstructive surgery. Prior publication on the computed tomographic angiography (CTA) perforator localization technique has demonstrated how soft tissue planning can be incorporated directly into existing VSP workflows. PURPOSE: The aim of this study is to prospectively assess the accuracy, precision, negative predictive value (NPV), and positive predictive value (PPV) of the CTA perforator localization technique for VSP of osteocutaneous fibular free flaps. MATERIALS AND METHODS: A prospective observational study in a consecutive cohort of subjects undergoing VSP of osteocutaneous fibular free flaps at Mayo Clinic between 2018 and 2020 was completed. All cutaneous perforators from the peroneal system of the selected donor leg were identified preoperatively through a previously reported CTA tracing method and registered into the VSP. Perforators were classified as primary or secondary based on whether the perforators were targeted for use in the final reconstructive plan. Perforator measurements obtained from the VSP were cross-referenced with intraoperatively obtained measurements of actual perforator locations to calculate accuracy, precision, NPV, PPV, sensitivity, and specificity of the CTA localization technique. RESULTS: Sixty consecutive subjects were enrolled in the study. A total of 141 perforators were identified preoperatively on CTA and 145 perforators were identified on operative exposure. One perforator identified on preoperative CTA was not identified on surgical exposure (false positive perforator). Six perforators were identified on operative exposure alone without recognition on preoperative CTA (false negative perforators). The accuracy of CTA perforator identification was 96.52%. Median precision of perforator localization was 0.3 cm (standard deviation 0.40) between CTA and operatively identified locations. PPV of the technique was 99.29% and NPV was 90.00%. CONCLUSION: The CTA localization technique for identifying and incorporating cutaneous perforator locations into VSP of osteocutaneous fibular free flaps is a reliable, accurate, and precise technique to employ in the modern paradigm of guided surgery for head and neck reconstruction.


Subject(s)
Computed Tomography Angiography , Fibula , Free Tissue Flaps , Head and Neck Neoplasms , Plastic Surgery Procedures , Angiography/methods , Bone Transplantation/methods , Computed Tomography Angiography/standards , Fibula/blood supply , Fibula/diagnostic imaging , Fibula/transplantation , Free Tissue Flaps/blood supply , Head , Head and Neck Neoplasms/surgery , Humans , Perforator Flap , Prospective Studies , Plastic Surgery Procedures/methods , Tomography, X-Ray Computed/methods
6.
Stroke ; 52(8): 2723-2733, 2021 08.
Article in English | MEDLINE | ID: mdl-34233464

ABSTRACT

BACKGROUND AND PURPOSE: The Stroke Treatment Academic Industry Roundtable (STAIR) sponsored an imaging session and workshop during the Stroke Treatment Academic Industry Roundtable XI via webinar on October 1 to 2, 2020, to develop consensus recommendations, particularly regarding optimal imaging at primary stroke centers. METHODS: This forum brought together stroke neurologists, neuroradiologists, neuroimaging research scientists, members of the National Institute of Neurological Disorders and Stroke, industry representatives, and members of the US Food and Drug Administration to discuss imaging priorities in the light of developments in reperfusion therapies, particularly in an extended time window, and reinvigorated interest in brain cytoprotection trials. RESULTS: The imaging session summarized and compared the imaging components of recent acute stroke trials and debated the optimal imaging strategy at primary stroke centers. The imaging workshop developed consensus recommendations for optimizing the acquisition, analysis, and interpretation of computed tomography and magnetic resonance acute stroke imaging, and also recommendations on imaging strategies for primary stroke centers. CONCLUSIONS: Recent positive acute stroke clinical trials have extended the treatment window for reperfusion therapies using imaging selection. Achieving rapid and high-quality stroke imaging is therefore critical at both primary and comprehensive stroke centers. Recommendations for enhancing stroke imaging research are provided.


Subject(s)
Clinical Trials as Topic/methods , Computed Tomography Angiography/methods , Consensus Development Conferences as Topic , Magnetic Resonance Imaging/methods , Stroke/diagnostic imaging , Tomography, X-Ray Computed/methods , Clinical Trials as Topic/standards , Computed Tomography Angiography/standards , Endovascular Procedures/methods , Endovascular Procedures/standards , Humans , Magnetic Resonance Imaging/standards , Stroke/therapy , Tomography, X-Ray Computed/standards , Treatment Outcome
7.
BMC Cardiovasc Disord ; 21(1): 154, 2021 03 26.
Article in English | MEDLINE | ID: mdl-33771107

ABSTRACT

BACKGROUND: Appropriate use criteria (AUC) have been developed in response to growth in cardiac imaging utilization and concern regarding associated costs. Cardiac computed tomography angiography (CCTA) has emerged as an important modality in the evaluation of coronary artery disease, however its appropriate utilization in actual practice is uncertain. Our objective was to determine the appropriate utilization of CCTA in a large quaternary care institution and to compare appropriate utilization pre and post publication of the 2013 AUC guidelines. We hypothesized that the proportion of appropriate CCTA utilization will be similar to those of other comparable cardiac imaging modalities and that there would be a significant increase in appropriate use post AUC publication. METHODS: We employed a retrospective cohort study design of 2577 consecutive patients undergoing CCTA between January 1, 2012 and December 30, 2016. An appropriateness category was assigned for each CCTA. Appropriateness classifications were compared pre- and post- AUC publication via the chi-square test. RESULTS: Overall, 83.5% of CCTAs were deemed to be appropriate based on the AUC. Before the AUC publication, 75.0% of CCTAs were classified as appropriate whereas after the AUC publication, 88.0% were classified as appropriate (p < 0.001). The increase in appropriate utilization, when extrapolated to the Medicare population of the United States, was associated with potential cost savings of approximately $57 million per year. CONCLUSIONS: We report a high rate of appropriate use of CCTA and a significant increase in the proportion of CCTAs classified as appropriate after the AUC publication.


Subject(s)
Computed Tomography Angiography , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Practice Patterns, Physicians' , Aged , Computed Tomography Angiography/economics , Computed Tomography Angiography/standards , Coronary Angiography/economics , Coronary Angiography/standards , Cost-Benefit Analysis , Female , Guideline Adherence , Health Care Costs , Humans , Male , Medicare , Middle Aged , Practice Guidelines as Topic , Practice Patterns, Physicians'/economics , Practice Patterns, Physicians'/standards , Predictive Value of Tests , Retrospective Studies , United States
8.
J Comput Assist Tomogr ; 45(2): 232-237, 2021.
Article in English | MEDLINE | ID: mdl-33369991

ABSTRACT

OBJECTIVE: The aims of this study were to evaluate image quality of virtual monoenergetic images (VMIs) compared with conventional images (CIs) from spectral detector CT (SDCT) and to explore the optimal energy level in run-off computed tomography angiography (CTA). METHODS: The data sets of 35 patients who received run-off CTA on the SDCT were collected in this retrospective study. Conventional images were generated via iterative reconstruction algorithm and VMI series from 40 to 120 keV were generated via spectral reconstruction algorithm. The objective indices including vascular attenuation, noise, signal-to-noise ratio, and contrast-to-noise ratio were compared. Two readers performed subjective evaluation using a 5-point scale. RESULTS: The attenuation showed higher values compared with CIs at 40 to 60 keV (P < 0.001). The noise was similar in 60- to 80-keV VMIs and significantly decreased in 90- to 120-keV VMIs (P < 0.001) in comparison with CIs. The signal-to-noise ratio and contrast-to-noise ratio were improved in 40- to 60-keV VMIs compared with CIs (P < 0.05). The score of subjective assessment was higher than that of CIs in 50- to 70-keV VMIs (P < 0.001). CONCLUSIONS: Virtual monoenergetic images can provide improved image quality compared with CIs from SDCT in run-off CTA, and VMIs at 60 keV may be the best choice in evaluating lower extremity arteries.


Subject(s)
Computed Tomography Angiography/methods , Computed Tomography Angiography/standards , Aged , Aged, 80 and over , Algorithms , Female , Femoral Artery/diagnostic imaging , Humans , Lower Extremity/blood supply , Lower Extremity/diagnostic imaging , Male , Middle Aged , Retrospective Studies , Signal-To-Noise Ratio
9.
Neurosurg Rev ; 44(2): 987-993, 2021 Apr.
Article in English | MEDLINE | ID: mdl-32166509

ABSTRACT

To evaluate if the unruptured intracranial aneurysm treatment score (UIATS) is a sensitive tool to detect aneurysms at risk of rupture, we conducted an a posteriori retrospective study on ruptured intracranial aneurysms. We performed a retrospective analysis of adult patients admitted to our center from January 2010 to April 2016 with aneurysmal subarachnoid hemorrhage. The UIATS was applied to all ruptured aneurysms. Patients for whom the UIATS recommended treatment were labeled as "true positives," whereas patients for whom the UIATS recommended observation were labeled as "false negatives." Patients for whom the UIATS was inconclusive were excluded from the final analysis. Based on the UIATS recommendation, a sensitivity analysis was performed. A total of 262 patients with aneurysmal subarachnoid hemorrhage were screened. Of these, 212 were included in our analysis. Median age was 53 years (23-90). Most patients were females (n = 134, 63%), with an equal distribution between low-grade and high-grade hemorrhages (Hunt & Hess ≥ 3 n = 107, 50%). UIATS recommended treatment in n = 52, 25% cases (TP), was inconclusive in n = 93, 44% (excluded), and recommended observation in n = 67, 32% (FN). Based on these data, the UIATS showed a sensitivity of 44% (CI 35-53%). The UIATS exhibits rather low sensitivity for detecting aneurysms at risk of rupture.


Subject(s)
Aneurysm, Ruptured/diagnostic imaging , Angiography, Digital Subtraction/standards , Computed Tomography Angiography/standards , Intracranial Aneurysm/diagnostic imaging , Severity of Illness Index , Adult , Aged , Aged, 80 and over , Aneurysm, Ruptured/therapy , Angiography, Digital Subtraction/methods , Cohort Studies , Computed Tomography Angiography/methods , Female , Humans , Intracranial Aneurysm/therapy , Male , Middle Aged , Retrospective Studies , Treatment Outcome
10.
J Integr Neurosci ; 20(4): 967-976, 2021 Dec 30.
Article in English | MEDLINE | ID: mdl-34997719

ABSTRACT

To evaluate the ability of a commercialized deep learning reconstruction technique to depict intracranial vessels on the brain computed tomography angiography and compare the image quality with filtered-back-projection and hybrid iterative reconstruction in terms of objective and subjective measures. Forty-three patients underwent brain computed tomography angiography, and images were reconstructed using three algorithms: filtered-back-projection, hybrid iterative reconstruction, and deep learning reconstruction. The image noise, computed tomography attenuation value, signal-to-noise ratio, and contrast-to-noise ratio were measured in the bilateral cavernous segment of the internal carotid artery, vertebral artery, basilar apex, horizontal segment of the middle cerebral artery and used for the objective assessment of the image quality among the three different reconstructions. The subjective image quality score was significantly higher for the deep learning reconstruction than hybrid iterative reconstruction and filtered-back-projection images. The deep learning reconstruction markedly improved the reduction of blooming artifacts in surgical clips and coiled aneurysms. The deep learning reconstruction method generally improves the image quality of brain computed tomography angiography in terms of objective measurement and subjective grading compared with filtered-back-projection and hybrid iterative reconstruction. Especially, deep learning reconstruction is deemed advantageous for better depiction of small vessels compared to filtered-back projection and hybrid iterative reconstruction.


Subject(s)
Cerebral Arteries/diagnostic imaging , Computed Tomography Angiography , Deep Learning , Image Processing, Computer-Assisted , Adolescent , Adult , Aged , Aged, 80 and over , Carotid Artery, Internal/diagnostic imaging , Computed Tomography Angiography/methods , Computed Tomography Angiography/standards , Female , Humans , Image Processing, Computer-Assisted/methods , Image Processing, Computer-Assisted/standards , Male , Middle Aged , Middle Cerebral Artery/diagnostic imaging , Retrospective Studies , Vertebral Artery/diagnostic imaging , Young Adult
11.
J Cell Mol Med ; 24(10): 5446-5453, 2020 05.
Article in English | MEDLINE | ID: mdl-32227625

ABSTRACT

No study has evaluated the impact of different iodinated contrast media on coronary contrast enhancement, using an injection protocol according to body surface area (BSA). Thus, the present study aimed to examine the usefulness and safety of personalized application of different iodine concentrations of contrast media in coronary computed tomographic (CT) angiography with a 2nd dual-source CT scanner in eliminating differences in coronary contrast enhancement based on a BSA-adapted injection protocol of contrast media. A total of 270 enrolled participants were randomly assigned to three groups: ioversol 320, ioversol 350 and iopromide 370 (n = 90 per group). The three groups were administered contrast media at a BSA-adjusted volume and flow rate with a fixed injection time of 15 seconds, and they subsequently received a 30-mL saline flush. All patients were scanned with a prospective electrocardiogram-gated protocol in a craniocaudal direction using a second-generation 128-slice dual-source CT system. The three iodinated contrast media used in coronary CT angiography exhibited similar diagnostic quality and safety. No significant differences were found in the contrast enhancement degrees, image quality scores, radiation doses and incidences of adverse effects among the three groups. The three contrast media used in coronary CT angiography with 320, 350 and 370 mg/mL iodine, respectively, have comparable diagnostic quality and safety. However, more large-scale, multinational, multi-centre and prospective trials are warranted.


Subject(s)
Computed Tomography Angiography , Contrast Media , Coronary Artery Disease/diagnostic imaging , Iodine , Trace Elements , Adult , Aged , Computed Tomography Angiography/methods , Computed Tomography Angiography/standards , Contrast Media/administration & dosage , Contrast Media/adverse effects , Contrast Media/chemistry , Coronary Artery Disease/pathology , Female , Humans , Image Processing, Computer-Assisted/methods , Image Processing, Computer-Assisted/standards , Male , Middle Aged
12.
Stroke ; 51(4): 1305-1308, 2020 04.
Article in English | MEDLINE | ID: mdl-31964287

ABSTRACT

Background and Purpose- In acute spontaneous intracerebral hemorrhage, multiple hematoma expansion scores have been proposed for use in clinical trial environments. We performed a systematic scoping review to identify all existing hematoma expansion scores and describe their development, validation, and relative performance. Methods- Two reviewers searched MEDLINE, PUBMED, EMBASE, and CENTRAL (Cochrane Central Register of Controlled Trials) for studies that derived or validated a hematoma expansion prediction score in adults presenting with spontaneous intracerebral hemorrhage. A descriptive analysis of the extracted data was performed, focusing on score development techniques and predictive capabilities. Results- Of the 14 434 records retrieved, 15 studies met inclusion criteria and 10 prediction scores were identified. Validation analysis using independent samples was performed in 9 studies on 5 scores. All derivation studies reported high performance with C statistics ranging from 0.72 to 0.93. In validation, the C-statistic range was broader with studies reporting 0.62 to 0.77. For every score, the risk of expansion increased with each point increase, although patients with high scores were rare. Conclusions- At present, 10 hematoma expansion scores have been developed, of which 5 have been externally validated. Real-world performance in validation studies was lower than performance in derivation studies. Data from the current literature are insufficient to support a meaningful meta-analysis.


Subject(s)
Cerebral Hemorrhage/diagnostic imaging , Computed Tomography Angiography/standards , Hematoma/diagnostic imaging , Severity of Illness Index , Cerebral Hemorrhage/complications , Hematoma/etiology , Humans , Reproducibility of Results
13.
Stroke ; 51(4): 1107-1110, 2020 04.
Article in English | MEDLINE | ID: mdl-32151235

ABSTRACT

Background and Purpose- Patients with intracerebral hemorrhage (ICH) are often subject to rapid deterioration due to hematoma expansion. Current prognostic scores are largely based on the assessment of baseline radiographic characteristics and do not account for subsequent changes. We propose that calculation of prognostic scores using delayed imaging will have better predictive values for long-term mortality compared with baseline assessments. Methods- We analyzed prospectively collected data from the multicenter PREDICT study (Prediction of Hematoma Growth and Outcome in Patients With Intracerebral Hemorrhage Using the CT-Angiography Spot Sign). We calculated the ICH Score, Functional Outcome in Patients With Primary Intracerebral Hemorrhage (FUNC) Score, and modified ICH Score using imaging data at initial presentation and at 24 hours. The primary outcome was mortality at 90 days. We generated receiver operating characteristic curves for all 3 scores, both at baseline and at 24 hours, and assessed predictive accuracy for 90-day mortality with their respective area under the curve. Competing curves were assessed with nonparametric methods. Results- The analysis included 280 patients, with a 90-day mortality rate of 25.4%. All 3 prognostic scores calculated using 24-hour imaging were more predictive of mortality as compared with baseline: the area under the curve was 0.82 at 24 hours (95% CI, 0.76-0.87) compared with 0.78 at baseline (95% CI, 0.72-0.84) for ICH Score, 0.84 at 24 hours (95% CI, 0.79-0.89) compared with 0.76 at baseline (95% CI, 0.70-0.83) for FUNC, and 0.82 at 24 hours (95% CI, 0.76-0.88) compared with 0.74 at baseline (95% CI, 0.67-0.81) for modified ICH Score. Conclusions- Calculation of the ICH Score, FUNC Score, and modified ICH Score using 24-hour imaging demonstrated better prognostic value in predicting 90-day mortality compared with those calculated at presentation.


Subject(s)
Cerebral Angiography/standards , Cerebral Hemorrhage/diagnostic imaging , Computed Tomography Angiography/standards , Hematoma/diagnostic imaging , Aged , Aged, 80 and over , Cerebral Angiography/trends , Cerebral Hemorrhage/mortality , Cohort Studies , Computed Tomography Angiography/trends , Female , Hematoma/mortality , Humans , Male , Middle Aged , Predictive Value of Tests , Prognosis , Prospective Studies , Treatment Outcome
14.
Crit Care Med ; 48(5): 704-708, 2020 05.
Article in English | MEDLINE | ID: mdl-32079894

ABSTRACT

OBJECTIVES: This study retrospectively applied Wells' score and YEARS algorithm to the same sample of patients to evaluate the predictive performance of each when compared with the gold standard CT pulmonary angiography. DESIGN: Retrospective analytical study. SETTING: A tertiary University Hospital in Ireland. PATIENTS: Data from 794 patients who underwent CT pulmonary angiography to rule out pulmonary embolism. INTERVENTIONS: Patients were analyzed using retrospective application of both Wells' score and YEARS algorithm. Sensitivity, specificity, and diagnostic odds ratio were calculated and compared. MEASUREMENTS AND MAIN RESULTS: Of 794 scans, 78 (9.8%) were positive for pulmonary embolism. The YEARS algorithm was more sensitive than the Wells' score (97.44% vs 74.36%) but was less specific (13.97% vs 33.94%). Furthermore, the diagnostic odds ratio of YEARS was higher than Wells' score (6.27 vs 1.48). YEARS provides better negative predictive value (98% vs 92.4%), and both scores have poor positive predictive value (10.9%). CONCLUSIONS: Both scores successfully exclude pulmonary embolism, although YEARS has a better negative predictive value. Both exhibit poor positive predictive value.


Subject(s)
Algorithms , Pulmonary Embolism/diagnosis , Surveys and Questionnaires/standards , Adult , Aged , Aged, 80 and over , Computed Tomography Angiography/standards , Female , Fibrin Fibrinogen Degradation Products/analysis , Humans , Ireland , Male , Middle Aged , Predictive Value of Tests , Pulmonary Embolism/diagnostic imaging , Retrospective Studies , Risk Assessment , Socioeconomic Factors , Tertiary Care Centers
15.
Int J Legal Med ; 134(1): 321-337, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31455980

ABSTRACT

BACKGROUND: The aim of this study was to evaluate the sensitivity of postmortem computed tomography (PMCT), postmortem magnetic resonance imaging (PMMR) and PMCT angiography (PMCTA) compared with autopsy in cases of adult death investigations. METHODS: For this systematic review and meta-analysis, Embase, PubMed, Scopus, Web of Science and Medline were searched for eligible studies in October 2016; a follow-up literature search was conducted in March 2018. Studies referring to PMCT, PMCTA and/or PMMR of more than 3 cases with subsequent autopsy were included. Data were extracted from published texts in duplicate. The extracted outcomes were categorized as follows: soft tissue and organ findings, skeletal injuries, haemorrhages, abnormal gas accumulations and causes of death. The summary measure was sensitivity, if 3 or more studies were available. To combine studies, a random effects model was used. Variability and heterogeneity within the meta-analysis was assessed. RESULTS: Of 1053 studies, 66 were eligible, encompassing a total of 4213 individuals. For soft tissue and organ findings, there was a high pooled sensitivity with PMCTA (0.91, 95% CI 0.81-0.96), without evidence for between-study variability (Cochrane's Q test p = 0.331, I2 = 24.5%). The pooled sensitivity of PMCT+PMMR was very high in skeletal injuries (0.97, CI 0.87-0.99), without evidence for variability (p = 0.857, I2 = 0.0%). In detecting haemorrhages, the pooled sensitivity for PMCT+PMMR was the highest (0.88, 95% CI 0.35-0.99), with strong evidence of heterogeneity (p < 0.05, I2 > 50%). Pooled sensitivity for the correct cause of death was the highest for PMCTA with 0.79 (95% CI 0.52-0.93), again with evidence of heterogeneity (p = 0.062, I2 > 50%). CONCLUSION: Distinct postmortem imaging modalities can achieve high sensitivities for detecting various findings and causes of death. This knowledge should lead to a reasoned use of each modality. Both forensic evidence and in-hospital medical quality would be enhanced.


Subject(s)
Autopsy/methods , Computed Tomography Angiography/standards , Magnetic Resonance Imaging/standards , Tomography, X-Ray Computed/standards , Adult , Blood Gas Analysis , Bone and Bones/diagnostic imaging , Cause of Death , Hemorrhage/diagnostic imaging , Humans , Reference Standards , Sensitivity and Specificity
16.
AJR Am J Roentgenol ; 215(3): 726-735, 2020 09.
Article in English | MEDLINE | ID: mdl-32755200

ABSTRACT

OBJECTIVE. Pediatric CT angiography (CTA) presents unique challenges compared with adult CTA. Because of the ionizing radiation exposure, CTA should be used judiciously in children. The pearls offered here are observations gleaned from the authors' experience in the use of pediatric CTA. We also present some potential follies to be avoided. CONCLUSION. Understanding the underlying principles and paying meticulous attention to detail can substantially optimize dose and improve the diagnostic quality of pediatric CTA.


Subject(s)
Computed Tomography Angiography/standards , Pediatrics , Contrast Media , Humans , Radiation Dosage
17.
Radiographics ; 40(3): 629-652, 2020.
Article in English | MEDLINE | ID: mdl-32281902

ABSTRACT

Coronary CT angiography is now established as the first-line diagnostic imaging test to exclude coronary artery disease (CAD) in the population at low to intermediate risk. Wide variability exists in both the reporting of coronary CT angiography and the interpretation of these reports by referring physicians. The CAD Reporting and Data System (CAD-RADS) is sponsored by multiple societies and is a collaborative effort to provide standard classification of CAD, which is then integrated into patient clinical care. The main goals of the CAD-RADS are to decrease variability among readers; enhance communication between interpreting and referring clinicians, allowing collaborative determination of the best course of patient care; and generate consistent data for auditing, data mining, quality improvement, research, and education. There are several scenarios in which the CAD-RADS guidelines are ambiguous or do not provide definite recommendations for further management of CAD. The authors discuss the CAD-RADS categories and modifiers, highlight a variety of complex or ambiguous scenarios, and provide recommendations for managing these scenarios. Online supplemental material is available for this article. ©RSNA, 2020 See discussion on this article by Aviram and Wolak.


Subject(s)
Computed Tomography Angiography/standards , Coronary Angiography/standards , Coronary Artery Disease/diagnostic imaging , Documentation/standards , Electronic Health Records/standards , Coronary Artery Disease/classification , Humans , North America , Practice Guidelines as Topic , Reproducibility of Results
18.
Eur J Nucl Med Mol Imaging ; 46(8): 1596-1604, 2019 Jul.
Article in English | MEDLINE | ID: mdl-31044265

ABSTRACT

PURPOSE: This pilot study assessed the independent and incremental value of 68Ga-V/Q PET/CT as compared with CT pulmonary angiography (CTPA) for the management of cancer patients with suspected acute pulmonary embolism (PE). METHODS: All 24 cancer patients with suspected acute PE prospectively recruited underwent both 68Ga-V/Q PET/CT and CTPA within 24 h. PET/CT was acquired after inhalation of Galligas prepared using a Technegas generator and administration of 68Ga-macroaggregated albumin. Initially, PET/CT and CTPA scans were read independently with the reader blinded to the results of the other imaging study. CTPA and PET/CT were then coregistered and reviewed by consensus between a radiologist and nuclear medicine physician. The therapeutic management was established by the managing physician based on all available data. RESULTS: The diagnostic conclusion was concordantly negative in 18 patients (75%). Of the six discordant diagnoses on independent reading, combined interpretation of V/Q PET/CTPA enabled a consensus conclusion in two patients, excluding PE in one and confirming PE in the other, similar to the initial diagnostic conclusion of the V/Q PET/CT. Of the remaining four patients, three had a single subsegmental thrombus on CTPA but a negative V/Q PET/CT scan, and two of these did not receive long-term anticoagulation and did not have a venous thromboembolic event during a 3-year follow-up period. The third patient, along with a patient with a positive V/Q PET/CT scan but a negative CTPA scan, presented with acute complications preventing any conclusions with regard to the appropriateness of the V/Q PET/CT results in the management of PE. Overall, V/Q PET had an impact on management in four patients (17%). CONCLUSION: In this pilot study, we demonstrated the feasibility and potential utility of V/Q PET/CT for the management of patients with suspected PE. V/Q PET/CT may be of particular relevance in patients with equivocal findings or isolated subsegmental findings on CTPA, adding further discriminatory information to allow important decision-making regarding the use or withholding of anticoagulation. Given the other advantages of V/Q PET/CT (reduced acquisition time, low radiation dose), and with the increasing availability of 68Ga generators, PET/CT is a potential replacement for V/Q SPECT/CT imaging.


Subject(s)
Computed Tomography Angiography/methods , Perfusion Imaging/methods , Positron Emission Tomography Computed Tomography/methods , Pulmonary Embolism/diagnostic imaging , Adult , Aged , Computed Tomography Angiography/standards , Female , Gallium Radioisotopes , Humans , Male , Middle Aged , Perfusion Imaging/standards , Pilot Projects , Positron Emission Tomography Computed Tomography/standards , Radiopharmaceuticals
19.
Eur Radiol ; 29(11): 6129-6139, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31028446

ABSTRACT

OBJECTIVES: We sought to evaluate the accuracy of standardized total plaque volume (TPV) measurement and low-density non-calcified plaque (LDNCP) assessment from coronary CT angiography (CTA) in comparison with intravascular ultrasound (IVUS). METHODS: We analyzed 118 plaques without extensive calcifications from 77 consecutive patients who underwent CTA prior to IVUS. CTA TPV was measured with semi-automated software comparing both scan-specific (automatically derived from scan) and fixed attenuation thresholds. From CTA, %LDNCP was calculated voxels below multiple LDNCP thresholds (30, 45, 60, 75, and 90 Hounsfield units [HU]) within the plaque. On IVUS, the lipid-rich component was identified by echo attenuation, and its size was measured using attenuation score (summed score ∕ analysis length) based on attenuation arc (1 = < 90°; 2 = 90-180°; 3 = 180-270°; 4 = 270-360°) every 1 mm. RESULTS: TPV was highly correlated between CTA using scan-specific thresholds and IVUS (r = 0.943, p < 0.001), with no significant difference (2.6 mm3, p = 0.270). These relationships persisted for calcification patterns (maximal IVUS calcium arc of 0°, < 90°, or ≥ 90°). The fixed thresholds underestimated TPV (- 22.0 mm3, p < 0.001) and had an inferior correlation with IVUS (p < 0.001) compared with scan-specific thresholds. A 45-HU cutoff yielded the best diagnostic performance for identification of lipid-rich component, with an area under the curve of 0.878 vs. 0.840 for < 30 HU (p = 0.023), and corresponding %LDNCP resulted in the strongest correlation with the lipid-rich component size (r = 0.691, p < 0.001). CONCLUSIONS: Standardized noninvasive plaque quantification from CTA using scan-specific thresholds correlates highly with IVUS. Use of a < 45-HU threshold for LDNCP quantification improves lipid-rich plaque assessment from CTA. KEY POINTS: • Standardized scan-specific threshold-based plaque quantification from coronary CT angiography provides an accurate total plaque volume measurement compared with intravascular ultrasound. • Attenuation histogram-based low-density non-calcified plaque quantification can improve lipid-rich plaque assessment from coronary CT angiography.


Subject(s)
Algorithms , Computed Tomography Angiography/standards , Coronary Angiography/standards , Coronary Artery Disease/diagnosis , Coronary Vessels/diagnostic imaging , Plaque, Atherosclerotic/diagnosis , Ultrasonography, Interventional/standards , Aged , Female , Humans , Male , Middle Aged , Reproducibility of Results
20.
Eur Radiol ; 29(11): 5961-5970, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31089848

ABSTRACT

PURPOSE: In a prospective cohort study, we evaluated the diagnostic accuracy of time-resolved CT angiography (4D-CTA) compared to digital subtraction angiography (DSA) for detecting cranial arteriovenous shunts. MATERIAL AND METHODS: Patients were enrolled if a DSA had been ordered querying either a dural arteriovenous fistula (dAVF) or a cerebral arteriovenous malformation (bAVM). After enrolment, both a DSA and a 4D-CTA were performed. Both studies were evaluated using a standardized form. If a dAVF or bAVM was found, its classification, angioarchitectural details, and treatment options were recorded. RESULTS: Ninety-eight patients were enrolled and 76 full datasets were acquired. DSA demonstrated a shunting lesion in 28 out of 76 cases (prevalence 37%). 4D-CTA demonstrated all but two of these lesions (sensitivity of 93%) and produced one false positive (specificity of 98%). These numbers yielded a positive predictive value (PPV) of 96% and a negative predictive value (NPV) of 96%. Significant doubt regarding the 4D-CTA diagnosis was reported in 6.6% of all cases and both false-negative 4D-CTA results were characterized by such doubt. CONCLUSIONS: 4D-CTA has very high sensitivity and specificity for the detection of intracranial arteriovenous shunts. Based on these results, 4D-CTA may replace DSA imaging as a first modality in the diagnostic workup in a large number of patients suspected of a cranial dAVF or bAVM, especially if there is no doubt regarding the 4D-CTA diagnosis. KEY POINTS: • 4D-CTA was shown to have a high diagnostic accuracy and is an appropriate, less invasive replacement for DSA as a diagnostic tool for cranial arteriovenous shunts in the majority of suspected cases. • Doubt regarding the 4D-CTA result should prompt additional DSA imaging, as it is associated with false negatives. • False-positive 4D-CTA results are rare, but do exist.


Subject(s)
Central Nervous System Vascular Malformations/diagnostic imaging , Computed Tomography Angiography/standards , Intracranial Arteriovenous Malformations/diagnostic imaging , Angiography, Digital Subtraction/methods , Arteriovenous Anastomosis/diagnostic imaging , Computed Tomography Angiography/methods , Female , Four-Dimensional Computed Tomography/standards , Humans , Male , Middle Aged , Prospective Studies , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL