Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Br J Surg ; 111(9)2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39213397

RESUMEN

BACKGROUND: Several ablation confirmation software methods for minimum ablative margin assessment have recently been developed to improve local outcomes for patients undergoing thermal ablation of colorectal liver metastases. Previous assessments were limited to single institutions mostly at the place of development. The aim of this study was to validate the previously identified 5 mm minimum ablative margin (A0) using autosegmentation and biomechanical deformable image registration in a multi-institutional setting. METHODS: This was a multicentre, retrospective study including patients with colorectal liver metastases undergoing CT- or ultrasound-guided microwave or radiofrequency ablation during 2009-2022, reporting 3-year local disease progression (residual unablated tumour or local tumour progression) rates by minimum ablative margin across all institutions and identifying an intraprocedural contrast-enhanced CT-based minimum ablative margin associated with a 3-year local disease progression rate of less than 1%. RESULTS: A total of 400 ablated colorectal liver metastases (median diameter of 1.5 cm) in 243 patients (145 men; median age of 62 [interquartile range 54-70] years) were evaluated, with a median follow-up of 26 (interquartile range 17-40) months. A total of 119 (48.9%) patients with 186 (46.5%) colorectal liver metastases were from international institutions B, C, and D that were not involved in the software development. Three-year local disease progression rates for 0 mm, >0 and <5 mm, and 5 mm or larger minimum ablative margins were 79%, 15%, and 0% respectively for institution A (where the software was developed) and 34%, 19%, and 2% respectively for institutions B, C, and D combined. Local disease progression risk decreased to less than 1% with an intraprocedurally confirmed minimum ablative margin greater than 4.6 mm. CONCLUSION: A minimum ablative margin of 5 mm or larger demonstrates optimal local oncological outcomes. It is proposed that an intraprocedural minimum ablative margin of 5 mm or larger, confirmed using biomechanical deformable image registration, serves as the A0 for colorectal liver metastasis thermal ablation.


Asunto(s)
Inteligencia Artificial , Neoplasias Colorrectales , Neoplasias Hepáticas , Márgenes de Escisión , Tomografía Computarizada por Rayos X , Humanos , Neoplasias Colorrectales/patología , Neoplasias Colorrectales/diagnóstico por imagen , Neoplasias Hepáticas/secundario , Neoplasias Hepáticas/cirugía , Neoplasias Hepáticas/diagnóstico por imagen , Masculino , Estudios Retrospectivos , Femenino , Persona de Mediana Edad , Anciano , Progresión de la Enfermedad , Ablación por Radiofrecuencia/métodos
2.
Eur Radiol ; 34(9): 5541-5550, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38334762

RESUMEN

PURPOSE: To investigate the correlation of minimal ablative margin (MAM) quantification using biomechanical deformable (DIR) versus intensity-based rigid image registration (RIR) with local outcomes following colorectal liver metastasis (CLM) thermal ablation. METHODS: This retrospective single-institution study included consecutive patients undergoing thermal ablation between May 2016 and October 2021. Patients who did not have intraprocedural pre- and post-ablation contrast-enhanced CT images for MAM quantification or follow-up period less than 1 year without residual tumor or local tumor progression (LTP) were excluded. DIR and RIR methods were used to quantify the MAM. The registration accuracy was compared using Dice similarity coefficient (DSC). Area under the receiver operating characteristic curve (AUC) was used to test MAM in predicting local tumor outcomes. RESULTS: A total of 72 patients (mean age 57; 44 men) with 139 tumors (mean diameter 1.5 cm ± 0.8 (SD)) were included. During a median follow-up of 29.4 months, there was one residual unablated tumor and the LTP rate was 17% (24/138). The ranges of DSC were 0.96-0.98 and 0.67-0.98 for DIR and RIR, respectively (p < 0.001). When using DIR, 27 (19%) tumors were partially or totally registered outside the liver, compared to 46 (33%) with RIR. Using DIR versus RIR, the corresponding median MAM was 4.7 mm versus 4.0 mm, respectively (p = 0.5). The AUC in predicting residual tumor and 1-year LTP for DIR versus RIR was 0.89 versus 0.72, respectively (p < 0.001). CONCLUSION: Ablative margin quantified on intra-procedural CT imaging using DIR method outperformed RIR for predicting local outcomes of CLM thermal ablation. CLINICAL RELEVANCE STATEMENT: The study supports the role of biomechanical deformable image registration as the preferred image registration method over rigid image registration for quantifying minimal ablative margins using intraprocedural contrast-enhanced CT images. KEY POINTS: • Accurate and reproducible image registration is a prerequisite for clinical application of image-based ablation confirmation methods. • When compared to intensity-based rigid image registration, biomechanical deformable image registration for minimal ablative margin quantification was more accurate for liver registration using intraprocedural contrast-enhanced CT images. • Biomechanical deformable image registration outperformed intensity-based rigid image registration for predicting local tumor outcomes following colorectal liver metastasis thermal ablation.


Asunto(s)
Neoplasias Colorrectales , Neoplasias Hepáticas , Tomografía Computarizada por Rayos X , Humanos , Masculino , Femenino , Neoplasias Hepáticas/secundario , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/cirugía , Neoplasias Colorrectales/patología , Neoplasias Colorrectales/diagnóstico por imagen , Neoplasias Colorrectales/cirugía , Estudios Retrospectivos , Persona de Mediana Edad , Tomografía Computarizada por Rayos X/métodos , Márgenes de Escisión , Anciano , Resultado del Tratamiento , Adulto
3.
BMC Med Res Methodol ; 23(1): 250, 2023 10 26.
Artículo en Inglés | MEDLINE | ID: mdl-37884857

RESUMEN

BACKGROUND: Evidence-based treatment decisions in medicine are made founded on population-level evidence obtained during randomized clinical trials. In an era of personalized medicine, these decisions should be based on the predicted benefit of a treatment on a patient-level. Survival prediction models play a central role as they incorporate the time-to-event and censoring. In medical applications uncertainty is critical especially when treatments differ in their side effect profiles or costs. Additionally, models must be adapted to local populations without diminishing performance and often without the original training data available due to privacy concern. Both points are supported by Bayesian models-yet they are rarely used. The aim of this work is to evaluate Bayesian parametric survival models on public datasets including cardiology, infectious diseases, and oncology. MATERIALS AND METHODS: Bayesian parametric survival models based on the Exponential and Weibull distribution were implemented as a Python package. A linear combination and a neural network were used for predicting the parameters of the distributions. A superiority design was used to assess whether Bayesian models are better than commonly used models such as Cox Proportional Hazards, Random Survival Forest, and Neural Network-based Cox Proportional Hazards. In a secondary analysis, overfitting was compared between these models. An equivalence design was used to assess whether the prediction performance of Bayesian models after model updating using Bayes rule is equivalent to retraining on the full dataset. RESULTS: In this study, we found that Bayesian parametric survival models perform as good as state-of-the art models while requiring less hyperparameters to be tuned and providing a measure of the uncertainty of the predictions. In addition, these models were less prone to overfitting. Furthermore, we show that updating these models using Bayes rule yields equivalent performance compared to models trained on combined original and new datasets. CONCLUSIONS: Bayesian parametric survival models are non-inferior to conventional survival models while requiring less hyperparameter tuning, being less prone to overfitting, and allowing model updating using Bayes rule. Further, the Bayesian models provide a measure of the uncertainty on the statistical inference, and, in particular, on the prediction.


Asunto(s)
Redes Neurales de la Computación , Humanos , Teorema de Bayes , Incertidumbre
4.
Cancers (Basel) ; 16(11)2024 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-38893214

RESUMEN

Microwave ablation (MWA) of liver tumors presents challenges like under- and over-ablation, potentially leading to inadequate tumor destruction and damage to healthy tissue. This study aims to develop personalized three-dimensional (3D) models to simulate MWA for liver tumors, incorporating patient-specific characteristics. The primary objective is to validate the predicted ablation zones compared to clinical outcomes, offering insights into MWA before therapy to facilitate accurate treatment planning. Contrast-enhanced CT images from three patients were used to create 3D models. The simulations used coupled electromagnetic wave propagation and bioheat transfer to estimate the temperature distribution, predicting tumor destruction and ablation margins. The findings indicate that prolonged ablation does not significantly improve tumor destruction once an adequate margin is achieved, although it increases tissue damage. There was a substantial overlap between the clinical ablation zones and the predicted ablation zones. For patient 1, the Dice score was 0.73, indicating high accuracy, with a sensitivity of 0.72 and a specificity of 0.76. For patient 2, the Dice score was 0.86, with a sensitivity of 0.79 and a specificity of 0.96. For patient 3, the Dice score was 0.8, with a sensitivity of 0.85 and a specificity of 0.74. Patient-specific 3D models demonstrate potential in accurately predicting ablation zones and optimizing MWA treatment strategies.

5.
Invest Radiol ; 59(4): 314-319, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-37812469

RESUMEN

OBJECTIVES: The aim of this study was to investigate the prognostic value of 3-dimensional minimal ablative margin (MAM) quantified by intraprocedural versus initial follow-up computed tomography (CT) in predicting local tumor progression (LTP) after colorectal liver metastasis (CLM) thermal ablation. MATERIALS AND METHODS: This single-institution, patient-clustered, tumor-based retrospective study included patients undergoing microwave and radiofrequency ablation between 2016 and 2021. Patients without intraprocedural and initial follow-up contrast-enhanced CT, residual tumors, or with follow-up less than 1 year without LTP were excluded. Minimal ablative margin was quantified by a biomechanical deformable image registration method with segmentations of CLMs on intraprocedural preablation CT and ablation zones on intraprocedural postablation and initial follow-up CT. Prognostic value of MAM to predict LTP was tested using area under the curve and competing-risk regression model. RESULTS: A total of 68 patients (mean age ± standard deviation, 57 ± 12 years; 43 men) with 133 CLMs were included. During a median follow-up of 30.3 months, LTP rate was 17% (22/133). The median volume of ablation zone was 27 mL and 16 mL segmented on intraprocedural and initial follow-up CT, respectively ( P < 0.001), with corresponding median MAM of 4.7 mm and 0 mm, respectively ( P < 0.001). The area under the curve was higher for MAM quantified on intraprocedural CT (0.89; 95% confidence interval [CI], 0.83-0.94) compared with initial follow-up CT (0.66; 95% CI, 0.54-0.76) in predicting 1-year LTP ( P < 0.001). An MAM of 0 mm on intraprocedural CT was an independent predictor of LTP with a subdistribution hazards ratio of 11.9 (95% CI, 4.9-28.9; P < 0.001), compared with 2.4 (95% CI, 0.9-6.0; P = 0.07) on initial follow-up CT. CONCLUSIONS: Ablative margin quantified on intraprocedural CT significantly outperformed initial follow-up CT in predicting LTP and should be used for ablation endpoint assessment.


Asunto(s)
Ablación por Catéter , Neoplasias Colorrectales , Neoplasias Hepáticas , Masculino , Humanos , Estudios de Seguimiento , Estudios Retrospectivos , Resultado del Tratamiento , Ablación por Catéter/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/cirugía , Neoplasias Hepáticas/patología , Neoplasias Colorrectales/patología
6.
Cardiovasc Intervent Radiol ; 46(12): 1748-1754, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37563313

RESUMEN

PURPOSE: This study aims to evaluate the technical efficacy and local tumor progression-free survival (LTPFS) of a standardized workflow for thermal ablation of colorectal liver metastases (CRLM) consisting of CT during hepatic arteriography (CTHA)-based imaging analysis, stereotactic thermal ablation, and computer-based software assessment of ablation margins. MATERIALS AND METHODS: This investigator initiated, single-center, single-arm prospective trial will enroll up to 50 patients (≤ 5 CRLM, Measuring ≤ 5 cm). Procedures will be performed in an angio-CT suite under general anesthesia. The primary objective is to estimate LTPFS with a follow-up of up to 2 years and secondary objectives are analysis of the impact of minimal ablative margins on LTPFS, adverse events, contrast media utilization and radiation exposure, overall oncological outcomes, and anesthesia/procedural time. Adverse events (AE) will be recorded by CTCAE (Common Toxicity Criteria for Adverse Events), and Bayesian optimal phase-2 design will be applied for major intraprocedural AE stop boundaries. The institutional CRLM ablation registry will be used as benchmark for comparative analysis with the historical cohort. DISCUSSION: The STEREOLAB trial will introduce a high-precision and standardized thermal ablation workflow for CRLM consisting of CT during hepatic arteriography imaging, stereotactic guidance, and ablation confirmation. Trial Registration ClinicalTrials.gov identifier: (NCT05361551).


Asunto(s)
Ablación por Catéter , Neoplasias Colorrectales , Neoplasias Hepáticas , Humanos , Angiografía , Teorema de Bayes , Ablación por Catéter/métodos , Neoplasias Colorrectales/patología , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/cirugía , Neoplasias Hepáticas/patología , Estudios Prospectivos , Estudios Retrospectivos , Programas Informáticos , Tomografía Computarizada por Rayos X/métodos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA