Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
1.
J Urol ; 209(1): 187-197, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36067387

RESUMEN

PURPOSE: This study aimed to evaluate the usefulness of the LDN-PSA (LacdiNAc-glycosylated-prostate specific antigen) in detecting clinically significant prostate cancer in patients suspected of having clinically significant prostate cancer on multiparametric magnetic resonance imaging. MATERIALS AND METHODS: Patients with prostate specific antigen levels ranging between 3.0 ng/mL and 20 ng/mL and suspicious lesions with PI-RADS (Prostate Imaging-Reporting and Data System) category ≥3 were included prospectively. The LDN-PSA was measured using an automated 2-step Wisteria floribunda agglutinin lectin-anti-prostate specific antigen antibody sandwich immunoassay. RESULTS: Two hundred four patients were included. Clinically significant prostate cancer was detected in 105 patients. On multivariable logistic regression analysis, prostate specific antigen density (OR 1.61, P = .010), LDN-PSAD (OR 1.04, P = .012), highest PI-RADS category (3 vs 4, 5; OR 14.5, P < .0001), and location of the lesion with highest PI-RADS category (transition zone vs peripheral zone) (OR 0.34, P = .009) were significant risk factors for detecting clinically significant prostate cancer. Among the patients with the highest PI-RADS category 3 (n=113), clinically significant prostate cancer was detected in 28 patients. On multivariable logistic regression analysis to predict the detection of clinically significant prostate cancer in patients with the highest PI-RADS category 3, age (OR 1.10, P = .026) and LDN-PSAD (OR 1.07, P < .0001) were risk factors for detecting clinically significant prostate cancer. CONCLUSIONS: LDN-PSAD would be a biomarker for detecting clinically significant prostate cancer in patients with prostate specific antigen levels ≤20 ng/mL and suspicious lesions with PI-RADS category ≥3. The use of LDN-PSAD as an adjunct to the use of prostate specific antigen levels would avoid unnecessary biopsies in patients with the highest PI-RADS category 3. Multi-institutional studies with large population are recommended.


Asunto(s)
Antígeno Prostático Específico , Neoplasias de la Próstata , Humanos , Masculino , Imagen por Resonancia Magnética , Neoplasias de la Próstata/diagnóstico por imagen
2.
J Clin Lab Anal ; 37(9-10): e24901, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37272760

RESUMEN

BACKGROUND: As next-generation sequencing (NGS) oncology tests vary by platform, application, and target of genes, specific methods for external quality assessment (EQA) have not been universally applied. Hence, we have attempted to implement on-site evaluation as EQA in the accreditation program under ISO 15189 for laboratories that perform NGS oncology tests. METHODS: A total of 10 laboratories that performed NGS oncology tests were enrolled. Two types of EQA samples were prepared (Acrometrix Oncology Hotspot Control DNA and OncoSpan gDNA DNA samples), and the variant allele frequency of targeted genes was assigned. The samples were subjected to NGS oncology tests in participant laboratories according to their routine protocols. Based on the result reports, auditors visited the participant laboratories to perform on-site evaluations and provided feedback regarding possible laboratory process improvement. RESULTS: The participant laboratories identified the targeted variants in the Acrometrix Oncology Hotspot Control DNA and OncoSpan gDNA samples with a success rate of 31-100% and 9.5-100%, respectively, compared with reference information, depending on their sequencing systems, and reported a few lower-variant allele frequencies. Six of the eight evaluated laboratories failed to report at least three pathogenic variants due to errors in wet-lab and/or dry-lab processes. Based on the feedback reports and self-assessment, auditors and laboratory staff discussed potential improvements to processes during on-site evaluations for laboratory accreditations. CONCLUSIONS: On-site evaluation as EQA for NGS oncology tests in the laboratory accreditation program under ISO 15189 was successfully implemented and proved applicable to a broad spectrum of NGS tests.


Asunto(s)
Secuenciación de Nucleótidos de Alto Rendimiento , Laboratorios , Humanos , Control de Calidad , Proyectos Piloto , Acreditación
3.
J Clin Lab Anal ; 36(1): e24146, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34837712

RESUMEN

BACKGROUND: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is the causative agent of coronavirus disease 2019 (COVID-19) and is capable of human-to-human transmission and rapid global spread. Thus, the establishment of high-quality viral detection and quantification methods, and the development of anti-SARS-CoV-2 agents are critical. METHODS: Here, we present the rapid detection of infectious SARS-CoV-2 particles using a plaque assay with 0.5% agarose-ME (Medium Electroosmosis) as an overlay medium. RESULTS: The plaques were capable of detecting the virus within 36-40 h post-infection. In addition, we showed that a monogalactosyl diacylglyceride isolated from a microalga (Coccomyxa sp. KJ) could inactivate the clinical isolates of SARS-CoV-2 in a time- and concentration-dependent manner. CONCLUSIONS: These results would allow rapid quantification of the infectious virus titers and help develop more potent virucidal agents against SARS-CoV-2.


Asunto(s)
Antivirales/farmacología , Galactosa/análogos & derivados , Glicéridos/farmacología , Microalgas/química , SARS-CoV-2/efectos de los fármacos , Animales , Antivirales/química , COVID-19/virología , Chlorocebus aethiops , Chlorophyta/química , Galactosa/química , Galactosa/farmacología , Glicéridos/química , Humanos , SARS-CoV-2/genética , SARS-CoV-2/aislamiento & purificación , Células Vero , Ensayo de Placa Viral
4.
Mar Drugs ; 20(2)2022 Feb 10.
Artículo en Inglés | MEDLINE | ID: mdl-35200660

RESUMEN

Human noroviruses are the most common pathogens causing acute gastroenteritis and may lead to more severe illnesses among immunosuppressed people, including elderly and organ transplant recipients. To date, there are no safe and effective vaccines or antiviral agents for norovirus infections. In the present study, we aimed to demonstrate the antiviral activity of monogalactosyl diacylglyceride (MGDG) isolated from a microalga, Coccomyxa sp. KJ, against murine norovirus (MNV) and feline calicivirus (FCV), the surrogates for human norovirus. MGDG showed virucidal activities against these viruses in a dose- and time-dependent manner-MGDG at 100 µg/mL reduced the infectivity of MNV and FCV to approximately 10% after 60 min incubation. In the animal experiments of MNV infection, intraoral administration of MGDG (1 mg/day) exerted a therapeutic effect by suppressing viral shedding in the feces and produced high neutralizing antibody titers in sera and feces. When MGDG was orally administered to immunocompromised mice treated with 5-fluorouracil, the compound exhibited earlier stopping of viral shedding and higher neutralizing antibody titers of sera than those in the control mice administered with distilled water. Thus, MGDG may offer a new therapeutic and prophylactic alternative against norovirus infections.


Asunto(s)
Antivirales/farmacología , Infecciones por Caliciviridae/tratamiento farmacológico , Galactolípidos/farmacología , Microalgas/metabolismo , Animales , Anticuerpos Neutralizantes/sangre , Antivirales/administración & dosificación , Antivirales/aislamiento & purificación , Infecciones por Caliciviridae/virología , Calicivirus Felino/efectos de los fármacos , Modelos Animales de Enfermedad , Relación Dosis-Respuesta a Droga , Femenino , Galactolípidos/administración & dosificación , Galactolípidos/aislamiento & purificación , Ratones , Ratones Endogámicos BALB C , Norovirus/efectos de los fármacos , Factores de Tiempo , Esparcimiento de Virus/efectos de los fármacos
5.
J Clin Microbiol ; 56(12)2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30232129

RESUMEN

In recent years, the diagnostic method of choice for Clostridium difficile infection (CDI) is a rapid enzyme immunoassay in which glutamate dehydrogenase (GDH) antigen and C. difficile toxin can be detected (C. diff Quik Chek Complete; Alere Inc.) (Quik Chek). However, the clinical significance remains unclear in cases that demonstrate a positive result for GDH antigen and are negative for toxin. In this study, we used the Quik Chek test kit on fecal samples, with an additional toxin detection step using a toxigenic culture assay for the aforementioned cases. CDI risk factors were assessed among the 3 groups divided by the Quik Chek test results. The study involved 1,565 fecal samples from patients suspected to have CDI who were hospitalized during the period of April 2012 to March 2014. The 3 groups were defined as follows: both GDH antigen positive and toxin positive (by Quik Chek test) (toxin-positive [TP] group, n = 109), both GDH antigen and toxin negative (toxin-negative [TN] group, n = 111), and positive only for GDH antigen but toxin positive with subsequent toxigenic culture (toxigenic culture [TC] group, n = 72). The gender, age, number of hospitalization days, white blood cell (WBC) counts, serum albumin levels, body mass index (BMI), fecal consistency, and use of antibacterials and proton pump inhibiters (PPIs) were analyzed. The positive rate for the fecal direct Quik Chek test was 7.0% (109/1,565 cases). However, toxigenic culture assays using the Quik Chek test for only the GDH-antigen-positive/toxin-negative samples were 35.3% positive (72/204 cases). As a result, the true positive rate for C. difficile toxin detection was estimated to be 11.6% (181/1,565 cases). Moreover, significant differences (P < 0.05) in the number of hospitalization days (>50 days), WBC counts (>10,000 WBCs/µl), and use of PPIs comparing the TN, TP, and TC groups, were observed. The odds ratios (ORs) for the development of CDI were 1.61 (95% confidence interval [CI], 0.94 to 2.74) and 2.98 (95% CI, 1.59 to 5.58) for numbers of hospitalization days, 2.16 (95% CI, 1.24 to 3.75) and 2.24 (95% CI, 1.21 to 4.14) for WBC counts, and 9.03 (95% CI, 4.9 to 16.6) and 9.15 (95% CI, 4.59 to 18.2) for use of PPIs in the TP and TC groups, respectively. These findings demonstrated that the use of PPIs was a significant risk factor for CDI development. Moreover, antibacterials such as carbapenems, cephalosporins, and fluoroquinolones were demonstrated to be risk factors. In conclusion, identification of the TC group of patients is thought to be important, as this study demonstrates that this group bears the same high risk of developing CDI as the TP group.


Asunto(s)
Clostridioides difficile/aislamiento & purificación , Infecciones por Clostridium/diagnóstico , Pruebas Diagnósticas de Rutina/normas , Técnicas para Inmunoenzimas/normas , Anciano , Anciano de 80 o más Años , Proteínas Bacterianas/análisis , Proteínas Bacterianas/genética , Toxinas Bacterianas/análisis , Toxinas Bacterianas/genética , Cromatografía de Afinidad , Reacciones Falso Negativas , Heces/química , Heces/microbiología , Femenino , Glutamato Deshidrogenasa/análisis , Humanos , Masculino , Persona de Mediana Edad , Pruebas de Neutralización/normas , Reacción en Cadena de la Polimerasa , Factores de Riesgo
7.
Parasitology ; 145(14): 1890-1895, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-29739480

RESUMEN

We have previously shown that the C-terminal region of the intermediate subunit of Entamoeba histolytica galactose- and N-acetyl-D-galactosamine-inhibitable lectin (C-Igl) is a useful antigen for serodiagnosis of amebiasis. An immunochromatographic kit was developed using fluorescent silica nanoparticles coated with C-Igl prepared in Escherichia coli. Samples for examination were added to the freeze-dried particles and then applied to the immunochromatographic device, in which a test line on the membrane was also coated with C-Igl. Fluorescent intensity was measured using a hand-held reader. In an evaluation of the kit using a human monoclonal antibody, the minimum amount of C-Igl specific antibody showing positive results was 100 pg. In the evaluation of serum samples with different antibody titers in indirect immunofluorescent antibody tests in the kit, 20 µL of serum was sufficient to obtain positive results at 30 min. Serum samples from symptomatic patients with amebic colitis and amebic liver abscess and those from asymptomatic E. histolytica-cyst carriers showed positive results in the kit. Based on evaluation using sera from healthy controls and patients with other infectious diseases, the sensitivity and specificity of the kit were 100 and 97.6%, respectively. Therefore, we conclude that the newly developed kit is useful for rapid serodiagnosis of amebiasis.


Asunto(s)
Amebiasis/diagnóstico , Anticuerpos Antiprotozoarios/sangre , Cromatografía de Afinidad/instrumentación , Juego de Reactivos para Diagnóstico , Pruebas Serológicas/instrumentación , Anticuerpos Monoclonales/inmunología , Antígenos de Protozoos/sangre , Disentería Amebiana/diagnóstico , Entamoeba histolytica , Entamebiasis/diagnóstico , Humanos , Absceso Hepático Amebiano/diagnóstico , Nanopartículas , Sensibilidad y Especificidad , Dióxido de Silicio
8.
Cardiology ; 137(3): 167-172, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28419986

RESUMEN

We encountered a 45-year-old Japanese man who suffered from pulmonary thromboembolism and huge right ventricular thrombus after inferior vena cava (IVC) filter implantation without apparent thrombus in either the deep veins or inside the IVC filter. The biochemical data showed a discrepancy in the level of fibrinogen between the immunological and thrombin time methods, suggesting hypodysfibrinogenemia. The sequencing of the fibrinogen γ-chain gene (FGG) revealed a novel heterozygous missense mutation in exon 8 - a TGT to TCT transversion in codon 326 - resulting in an amino acid substitution of serine for cysteine (γCys326Ser). The characterization of the protein did not show known mechanisms for thrombosis in dysfibrinogenemia, such as dimer or albumin-binding complex formation. In summary, the current case with a life-threatening thrombotic event was found to have a novel heterozygous missense mutation resulting in γCys326Ser, which was suggested as a predisposing factor of the thrombosis. Known mechanisms responsible for thrombosis in the current case were not demonstrated, suggesting other mechanisms including superimposing inherited and/or acquired risk factors. When a patient presents with unusual thrombosis such as breakthrough pulmonary embolism and huge thrombus in the right ventricle, as in the current case, the laboratory process for heritable thrombophilia should be considered.


Asunto(s)
Afibrinogenemia/genética , Fibrinógeno/genética , Mutación Missense , Embolia Pulmonar/diagnóstico por imagen , Trombosis/diagnóstico por imagen , Filtros de Vena Cava/efectos adversos , Heterocigoto , Humanos , Masculino , Persona de Mediana Edad , Embolia Pulmonar/genética , Trombosis/genética , Tomografía Computarizada por Rayos X
9.
Int J Mol Sci ; 18(1)2016 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-28025493

RESUMEN

Gene alterations are a well-established mechanism leading to drug resistance in acute leukemia cells. A full understanding of the mechanisms of drug resistance in these cells will facilitate more effective chemotherapy. In this study, we investigated the mechanism(s) of drug resistance in the human acute leukemia cell line MOLT-3 and its idarubicin-resistant derivative MOLT-3/IDR through complete mitochondrial and nuclear DNA analyses. We identified genetic differences between these two cell lines. The ND3 mutation site (p.Thr61Ile) in the mitochondrial DNA sequence was unique to MOLT-3/IDR cells. Moreover, we identified five candidate genes harboring genetic alterations, including GALNT2, via CGH array analysis. Sequencing of the GALNT2 exon revealed a G1716K mutation present within the stop codon in MOLT-3/IDR cells but absent from MOLT-3 cells. This mutation led to an additional 18 amino acids in the protein encoded by GALNT2. Using real-time PCR, we determined an expression value for this gene of 0.35. Protein structure predictions confirmed a structural change in GALNT2 in MOLT-3/IDR cells that corresponded to the site of the mutation. We speculate that this mutation may be related to idarubicin resistance.


Asunto(s)
Antibióticos Antineoplásicos/farmacología , Resistencia a Antineoplásicos/genética , Idarrubicina/farmacología , Polimorfismo Genético , Línea Celular Tumoral , Codón de Terminación/genética , ADN Mitocondrial/genética , Exones , Humanos , Mutación Missense , N-Acetilgalactosaminiltransferasas/genética , Polipéptido N-Acetilgalactosaminiltransferasa
10.
J Ultrasound Med ; 34(5): 783-8, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25911710

RESUMEN

OBJECTIVES: To evaluate the usefulness of sonography for monitoring the response to glucocorticoid treatment in patients with immunoglobulin G4 (IgG4)-related disease. METHODS: We conducted a retrospective study using sonography in 12 patients with bilateral swollen submandibular glands who had a diagnosis of IgG4-related disease based on an elevated serum IgG4 level (>135 mg/dL) and histopathologic findings between January 2010 and December 2012. Among these patients, 6 were treated with prednisolone, and the other 6 were placed under observation. B-mode sonographic examinations of the submandibular glands were performed with or without color Doppler imaging at the initial examination and 6 months later. Findings were compared between the groups (treated and untreated), and their relationship with the treatment response of the primarily involved organs was investigated. RESULTS: In the treated group, the submandibular glands of all 6 patients decreased in both size and volume after treatment (average volume ± SD, 27,449.7 ± 24,227.6 to 4609.7 ± 1911.4 mm(3); P = .004). The internal echo texture, characterized by multiple hypoechoic foci scattered against a heterogeneous hyperechoic background of submandibular tissue with demarcated hyperechoic lines, with or without hypoechoic tumor formation, disappeared or was obscured in all cases. In addition, the blood flow signals were reduced in all 3 patients who underwent color Doppler sonography, and the response observed on sonography was found to correlate with the IgG4 level and recovery of specific organ involvement. In contrast, in the untreated group, the submandibular glands showed a tendency to increase in both size and volume (average volume, 9326.3 ± 3054.8 to 12,217.4 ± 4605.5 mm(3); P= .2) without a decrease in the blood flow signals. CONCLUSIONS: Sonography is considered useful for evaluating the response to glucocorticoid therapy in patients with IgG4-related disease of the submandibular glands.


Asunto(s)
Enfermedades Autoinmunes/diagnóstico por imagen , Enfermedades Autoinmunes/tratamiento farmacológico , Inmunoglobulina G/inmunología , Enfermedades de la Glándula Submandibular/diagnóstico por imagen , Enfermedades de la Glándula Submandibular/tratamiento farmacológico , Ultrasonografía/métodos , Anciano , Anciano de 80 o más Años , Antiinflamatorios/uso terapéutico , Enfermedades Autoinmunes/inmunología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Prednisolona/uso terapéutico , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Enfermedades de la Glándula Submandibular/inmunología , Resultado del Tratamiento
11.
Rinsho Byori ; 63(7): 847-54, 2015 Jul.
Artículo en Japonés | MEDLINE | ID: mdl-26591436

RESUMEN

For the safety of patient care, a team-based approach has been advocated as an effective measure. In clinical physiology examination, we have been making efforts to promote good practice for patient safety based on such an approach in Tokai University Hospital, as represented by quality practice in ultrasonographic examination. The entire process of ultrasonographic examination can be divided into three parts: pre-examination, examination, and post-examination processes. In each process of the examination, specific quality issues must be considered, eventually ensuring the quality and safety of patient care. A laboratory physician is responsible for not only quality assurance of examination, diagnosis, and reporting, but also patient safety. A laboratory physician can play a key role in all aspects of patient safety related to each process of the examination by taking a leadership role in the team-based approach.


Asunto(s)
Sistemas de Información en Laboratorio Clínico , Seguridad del Paciente , Control de Calidad , Administración de la Seguridad , Ultrasonografía , Sistemas de Información en Laboratorio Clínico/normas , Humanos , Examen Físico , Administración de la Seguridad/normas
12.
J Clin Lab Anal ; 28(5): 341-8, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24648166

RESUMEN

BACKGROUND: Conventional automated hematology analyzers have limitations in platelet measurements such as poor accuracy and precision in the low count range and interference by nonplatelet particles. In order to improve it, the newly developed XN-Series automated hematology analyzers (Sysmex Corporation, Kobe, Japan) have been installed with a new dedicated channel for platelet analysis (PLT-F), which is based on a fluorescence flow cytometry method with uses of a novel fluorescent dye specifically staining platelets. We evaluated the basic performance of this new PLT-F channel. METHODS: Basic performance of the PLT-F channel in within-run reproducibility and assay linearity was studied using standard methods. Correlation was studied between PLT-F and a conventional automated hematology analyzer (XE-2100) and immunoplatelet analysis using anti-CD61 monoclonal antibody (Cell-Dyn Sapphire; Abbott Laboratories). The assay interference by nonplatelet particles such as fragmented red and white blood cells was evaluated by using clinical samples, respectively, from burn injury and acute leukemia. RESULTS: Basic performance of the PLT-F platelet counting was satisfactory in within-run reproducibility, linearity and correlation with the conventional analyzer. The correlation was satisfactory also with the immunoplatelet analysis, even for samples from a patient with burn injury, and those with white blood cell fragments displayed, platelet abnormal flag and low platelet counts (<50 × 10(9)/l). CONCLUSION: The platelet counting performance of the PLT-F channel of the XN Series had improved accuracy and precision in the low range and in abnormal samples, avoiding the interference by nonplatelet particles.


Asunto(s)
Plaquetas/metabolismo , Procesamiento Automatizado de Datos/métodos , Colorantes Fluorescentes , Pruebas Hematológicas/métodos , Recuento de Plaquetas/métodos , Quemaduras/patología , Citometría de Flujo/métodos , Humanos , Integrina beta3/metabolismo , Reproducibilidad de los Resultados , Estadística como Asunto
13.
Tokai J Exp Clin Med ; 49(2): 67-72, 2024 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-38904237

RESUMEN

OBJECTIVE: To develop and implement a pilot educational program on genetic testing at the Tokai University School of Medicine with a public engagement approach through a local junior-high school outreach program. METHODS: Seven medical students underwent 2 weeks of education and training to act as instructors for a one-day course on genetic testing for local junior-high school students. The one-day course comprised a lecture and an experimental lesson. The variation of UDP-glucuronosyltransferase 1A1 gene (UGT1A1) was selected as the teaching topic. A commercially available cultured human leukemia cell line was used as the source of human genomic DNA to circumvent the ethical concerns associated with obtaining samples from participants for genomic analysis. The medical students received instructions on the basics of conducting laboratory work and handling the equipment and reagents during the 2-week training. RESULTS: The seven medical students completed the 2-week training. They then taught PCR and restriction enzyme experiments and the meaning of the results to junior-high school students. CONCLUSION: A pilot educational program on genetic testing with a local community outreach approach was successfully developed and implemented.


Asunto(s)
Pruebas Genéticas , Estudiantes de Medicina , Proyectos Piloto , Pruebas Genéticas/métodos , Humanos , Relaciones Comunidad-Institución , Educación Médica/métodos
14.
Drug Discov Ther ; 18(1): 10-15, 2024 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-38355121

RESUMEN

A fluorescence immunochromatography (FIC) kit was developed recently using fluorescent silica nanoparticles coated with a recombinant C-terminal fragment of the surface lectin intermediate subunit (C-Igl) of Entamoeba histolytica to establish rapid serodiagnosis of amebiasis. We further evaluated the system using serum samples from 52 Thai patients with amebiasis. Of the patients, 50 (96%) tested positive using FIC. The samples were also tested using enzyme-linked immunosorbent assay (ELISA) with C-Igl as the antigen. Two samples were negative on ELISA but positive on FIC. The correlation coefficient between the fluorescence intensity using FIC and the optical density value using ELISA was 0.5390, indicating a moderate correlation between the two tests. Serum samples from 20 patients with malaria and 22 patients with Clostridioides difficile infection were also tested using FIC. The false-positive rates were 4/20 (20%) and 1/22 (4%) in patients with malaria and C. difficile infection, respectively. Combining the data from the present study with our previous study, the sensitivity and specificity of FIC were determined to be 98.5% and 95.2%, respectively. The results of the 50 samples were studied using a fluorescence scope and a fluorescence intensity reader, and the findings were compared. Disagreements were found in only two samples showing near-borderline fluorescence intensity, indicating that the use of scope was adequate for judging the results. These results demonstrate that FIC is a simple and rapid test for the serodiagnosis of amebiasis.


Asunto(s)
Amebiasis , Clostridioides difficile , Entamebiasis , Malaria , Nanopartículas , Humanos , Entamebiasis/diagnóstico , Dióxido de Silicio , Tailandia , Amebiasis/diagnóstico , Ensayo de Inmunoadsorción Enzimática/métodos , Pruebas Serológicas/métodos , Sensibilidad y Especificidad
15.
Adv Clin Exp Med ; 33(3): 225-232, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37386858

RESUMEN

BACKGROUND: The Coccomyxa sp. strain KJ (Coccomyxa KJ), a microalga found in Japan, has a potential function in controlling viral infections. Recently, its dry powder has been marketed as a health food product. OBJECTIVES: This pilot study investigated the effects of Coccomyxa KJ powder tablet intake on allergic reactions and immune functions in healthy participants. MATERIAL AND METHODS: Nine healthy volunteers (4 males and 5 females) who expressed interest in foods containing Coccomyxa KJ, and were willing to undergo blood tests, were recruited. Each individual was asked to take 2 Coccomyxa KJ powder tablets (0.3 g) before breakfast once a day for 4 weeks. The salivary immunoglobulin A (IgA) level and blood parameters (white blood cell (WBC) count, eosinophil and lymphocyte counts and percentages, natural killer (NK) cell activity, interleukin (IL)-6 level, and T helper (Th)1/Th2 cell ratio) were evaluated at baseline and weeks 2 and 4. RESULTS: The 4-week intake of Coccomyxa KJ did not affect salivary IgA levels, WBC count, eosinophil and lymphocyte counts and percentages, or the Th1/Th2 ratio. There were significant differences in the NK cell activity after 4 weeks, with an average increase of 11.78 (95% confidence interval (95% CI): 6.80-16.76). None of the patients experienced adverse reactions during or after the study. CONCLUSIONS: Long-term Coccomyxa KJ intake improved NK cell activity without causing adverse effects on the indicators of local immunity, systemic inflammation and immune response balance. This study suggests that Coccomyxa KJ powder tablets can induce beneficial immune modifications without causing any adverse effects.


Asunto(s)
Microalgas , Masculino , Femenino , Humanos , Proyectos Piloto , Alérgenos , Polvos , Interleucina-6 , Inmunoglobulina A
16.
J Ultrasound Med ; 32(5): 731-6, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23620313

RESUMEN

OBJECTIVES: The purpose of this study was to assess the relationship between the sonographic characteristics of the submandibular glands and organ involvement at the initial presentation in patients with immunoglobulin G4 (IgG4)-related disease. METHODS: We conducted a retrospective study that included 15 patients who had bilateral swollen submandibular glands and elevated serum IgG4 levels between January 2005 and December 2010. RESULTS: In all 15 patients, sonography revealed the involvement of both sides of the submandibular glands. The sonographic appearance of each gland was classified into two types: localized tumor-forming and diffuse focal types. On the basis of this typing, all 15 patients were classified into two groups: a group with the localized tumor-forming type observed on one or both sides of the glands (n = 10) and a group with the diffuse focal type present on both sides (n = 5). All 10 patients in the former group had lesions in local exocrine organs, such as the lacrimal and parotid glands, with regional lymphadenopathy. In contrast, all 5 patients in the latter group had lesions in abdominal organs, such as autoimmune pancreatitis and sclerosing cholangitis. CONCLUSIONS: The sonographic patterns of the submandibular glands in patients with IgG4-related disease can be divided into two types: localized tumor-forming and diffuse focal. The distinctive patient groups defined by the sonographic patterns in both glands were associated with differential organ involvement and thus could be used as indicators of the disease extension and specific organ involvement.


Asunto(s)
Inmunoglobulina G/inmunología , Insuficiencia Multiorgánica/diagnóstico por imagen , Paraproteinemias/diagnóstico por imagen , Paraproteinemias/inmunología , Enfermedades de las Glándulas Salivales/diagnóstico por imagen , Enfermedades de las Glándulas Salivales/inmunología , Glándula Submandibular/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Especificidad de Órganos , Ultrasonografía/métodos
18.
J Chemother ; 35(3): 188-197, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-35748502

RESUMEN

Various outcomes of mortality, medical costs, and antimicrobial usage result from antimicrobial stewardship (AS) programmes. Here, we clarified the effects of AS implementation by a well-trained pharmacist in an open intensive care unit (open ICU) through a retrospective, comparative study of 5123 open ICU patients of Tokai University Hospital. The 12 months before and after AS implementation were considered the control and study periods, respectively. After AS implementation, the number of AS cases increased significantly. The period until the implementation of therapeutic drug monitoring was significantly shortened, and antimicrobial drug usage increased significantly. The methicillin-resistant Staphylococcus aureus (MRSA) detection rate decreased significantly. Earlier and more frequent AS implementation could enhance treatment effects, possibly decreasing the MRSA incidence. Despite active AS implementation, antimicrobial drug usage did not necessarily decrease. ICU pharmacists with experience in AS should take on leadership roles and implement active AS strategies in open ICU settings.


Asunto(s)
Antiinfecciosos , Programas de Optimización del Uso de los Antimicrobianos , Staphylococcus aureus Resistente a Meticilina , Infecciones Estafilocócicas , Humanos , Farmacéuticos , Estudios Retrospectivos , Antiinfecciosos/uso terapéutico , Unidades de Cuidados Intensivos , Hospitales Universitarios , Infecciones Estafilocócicas/tratamiento farmacológico , Antibacterianos/uso terapéutico
19.
Sens Biosensing Res ; 39: 100549, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36686588

RESUMEN

Viral outbreaks, which include the ongoing coronavirus disease 2019 (COVID-19) pandemic provoked by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), are a major global crisis that enormously threaten human health and social activities worldwide. Consequently, the rapid and repeated treatment and isolation of these viruses to control their spread are crucial to address the COVID-19 pandemic and future epidemics of novel emerging viruses. The application of cost-efficient, rapid, and easy-to-operate detection devices with miniaturized footprints as a substitute for the conventional optic-based polymerase chain reaction (PCR) and immunoassay tests is critical. In this context, semiconductor-based electrical biosensors are attractive sensing platforms for signal readout. Therefore, this study aimed to examine the electrical sensing of patient-derived SARS-CoV-2 samples by harnessing the activity of DNA aptamers directed against spike proteins on viral surfaces. We obtained rapid and sensitive virus detection beyond the Debye length limitation by exploiting aptamers coupled with alkaline phosphatases, which catalytically generate free hydrogen ions which can readily be measured on pH meters or ion-sensitive field-effect transistors. Furthermore, we demonstrated the detection of the viruses of approximately 100 copies/µL in 10 min, surpassing the capability of typical immunochromatographic assays. Therefore, our newly developed technology has great potential for point-of-care testing not only for SARS-CoV-2, but also for other types of pathogens and biomolecules.

20.
Infect Dis Rep ; 15(1): 142-149, 2023 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-36826355

RESUMEN

In hospitals, outbreaks can occur due to pathogens accumulating in the areas around the wards' washbasins. Carbapenem-resistant Enterobacterales (CRE) was detected in an environmental survey in the high-care unit of a university hospital in Isehara, Japan, and effective cleaning methods were investigated. This study investigated methods of cleaning taps using commonly used detergents and disinfectants, and it assessed their effectiveness in removing hard scale and pathogens, including CRE. The taps were cleaned using various methods and cleaning agents, including environmentally neutral detergent, citric acid, baking soda, cleanser, 80% ethanol, 0.1% sodium hypochlorite, and a phosphoric acid-based environmental detergent (Space Shot). The cleaning effect was assessed based on the agent's effectiveness at removing hard scale from taps. Biofilms and scale were identified on taps, and several bacterial species were cultured. Only phosphoric acid-based detergent was effective at removing hard scale. After cleaning with the phosphoric acid-based detergent, the bacterial count decreased, and no CRE or other pathogens were detected. These results provide a reference for other facilities considering introducing this cleaning method.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA