Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Eur Radiol ; 27(6): 2292-2297, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27686566

RESUMEN

OBJECTIVES: To investigate the relationship between image quality and patient size at 100 kilovoltage (kV) compared to 120 kV ECG-gated Triple-Rule-Out CT angiography (TRO-CTA). METHODS: We retrospectively included 73 patients (age 64 ± 14 years) who underwent retrospective ECG-gated chest CTA. 40 patients were scanned with 100 kV while 33 patients with 120 kV. Body mass index (BMI), patients' chest circumference (PC) and thoracic surface area (TSA) were recorded. Quantitative image quality was assessed as vascular attenuation in the ascending aorta (AA), pulmonary trunk (PA) and left coronary artery (LCA) and the signal-to-noise ratio (SNR) in the AA. RESULTS: There was no significant difference in BMI (26.0 ± 4.6 vs. 28.0 ± 6.7 kg/m2), PC (103 ± 7 vs. 104 ± 10 cm2) and TSA (92 ± 15 vs. 91 ± 19 cm2) between 100 kV and 120 kV group. Mean vascular attenuation was significantly higher in the 100 kV compared to the 120 kV group (AA 438 vs. 354 HU, PA 460 vs. 349 HU, LCA 370 vs. 299 HU all p < 0.001). SNR was not significantly different, even after adjusting for patient size. Radiation dose was significantly lower in the 100 kV group (10.7 ± 4.1 vs. 20.7 ± 10.7 mSv; p < 0.001). CONCLUSIONS: 100 kV TRO-CTA is feasible in normal-to-overweight patients while maintaining image quality and achieving substantial dose reduction. KEY POINTS: • 100 kV protocols result in a significantly lower radiation dose. • Mean vascular attenuation is significantly higher using 100 kV. • SNR and CNR are not significantly different between 100 kV and 120 kV. • 100 kV CTA is feasible regardless of patient size while maintaining image quality.


Asunto(s)
Angiografía por Tomografía Computarizada/normas , Sobrepeso/diagnóstico por imagen , Aorta/diagnóstico por imagen , Índice de Masa Corporal , Tamaño Corporal , Angiografía por Tomografía Computarizada/métodos , Vasos Coronarios/diagnóstico por imagen , Electrocardiografía , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Arteria Pulmonar , Dosis de Radiación , Estudios Retrospectivos , Relación Señal-Ruido
2.
Eur J Radiol ; 81(11): 3592-7, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22495202

RESUMEN

PURPOSE: To investigate the prognostic value of perfusion defect volume (PDvol) at dual-energy-CT-angiography (DE-CTA) in patients with acute pulmonary embolism (PE) by correlating PDvol with CTA-obstruction-scores (OS), CT parameters of right-ventricular-dysfunction (RVD), and adverse-clinical-outcome. MATERIALS AND METHODS: DE-CTA of 60 patients (mean age: 65±14.4 years) with PE were analyzed. Iodine maps were generated, and normalized PDvol--defined as volume of perfusion defects/total lung volume--was quantified. Furthermore, established prognostic parameters (Qanadli and Mastora-OS, and CT parameters of RVD) were obtained. CT parameters of RVD--namely the right ventricle/left ventricle (RV/LV) diameter ratio measured on transverse sections (RV/LVtrans), four-chamber views (RV/LV4ch), and RV/LV volume ratios (RV/LVvol)--were assessed. PDvol was correlated with OS, CT parameters of RVD and adverse clinical outcome (defined as the need for intensive care treatment or death). RESULTS: 10 of 60 patients with PE experienced adverse clinical outcome. Patients with adverse clinical outcome showed significantly higher PDvol (35±11% vs. 23±10%, p=0.002), RV/LV ratios (RV/LV4ch 1.46±0.32 vs. 1.18±0.26, p=0.005; RV/LVvol 2.25±1.33 vs. 1.19±0.56, p=0.002) and higher Mastora global scores (52 vs. 13, p=0.02) compared to those without adverse clinical outcome. A weak correlation was observed between PDvol and the Mastora global score (r=0.5; p=0.0003), as well as between PDvol and RV/LV4Ch (r=0.432, p=0.0006). No correlation was found between PDvol and the Qanadli score or the remainder of the RVD-CT parameters. CONCLUSION: The extent of perfusion defects as assessed by DE-CTA correlates with adverse clinical outcome in patients with PE. Therefore, volumetric quantification of perfusion defects at DE-CTA allows the identification of low-risk patients who do not require intensified monitoring and treatment.


Asunto(s)
Embolia Pulmonar/diagnóstico por imagen , Embolia Pulmonar/mortalidad , Imagen Radiográfica por Emisión de Doble Fotón/estadística & datos numéricos , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Disfunción Ventricular Derecha/diagnóstico por imagen , Disfunción Ventricular Derecha/mortalidad , Adulto , Anciano , Anciano de 80 o más Años , Angiografía/estadística & datos numéricos , Comorbilidad , Femenino , Alemania/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Imagen de Perfusión Miocárdica/estadística & datos numéricos , Prevalencia , Pronóstico , Reproducibilidad de los Resultados , Factores de Riesgo , Sensibilidad y Especificidad , Estadística como Asunto , Análisis de Supervivencia , Tasa de Supervivencia , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA