Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Mymensingh Med J ; 24(3): 572-7, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26329957

RESUMEN

A cross sectional comparative study was conducted at Dhaka National Medical College, Dhaka from January to June 2012, to observe the accuracy of clinical and ultrasonographic estimation of foetal weight at term in our environment. Seventy five pregnant women who fulfilled the inclusion criteria had their foetal weight estimated independently using clinical and ultrasonographic methods. Accuracy was determined by percentage error, absolute percentage error and proportion of estimates within 10% of actual birth weight (birth weight fetus of +10%). Statistical analysis was done using the paired t-test, the Wilcoxon signed-rank test, and the chi-square test. The study sample had an actual average birth weight of 2989.60 ± 408.76 (range 2310-4000 gm). Overall, the clinical method overestimated birth-weight, while ultrasound underestimated it. The mean absolute percentage error of the clinical method was more than that of the sonographic method, and the number of estimates within 10% of actual birth weight for the clinical method (41.3%) was less than for the sonographic method (57.3%); the difference was not statistically significant. In the low birth-weight (<2,500 gm) group, the mean absolute percentage error of sonographic estimates were significantly smaller. Significantly more sonographic estimates (75%) were within 10% of actual birth-weight than those of the clinical method (0%). No statistically significant difference was observed in all the measures of accuracy for the normal birth-weight range of 2,500-<4,000 gm and in the macrosomic group (≥ 4,000 gm). Clinical estimation of birth-weight is as accurate as routine ultrasonographic estimation, except in low-birth-weight babies.


Asunto(s)
Peso Fetal , Ultrasonografía Prenatal/métodos , Adulto , Bangladesh , Peso al Nacer , Estudios Transversales , Femenino , Humanos , Recién Nacido de Bajo Peso , Recién Nacido , Embarazo , Tercer Trimestre del Embarazo , Reproducibilidad de los Resultados , Adulto Joven
2.
Rev Sci Instrum ; 83(5): 053904, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22667630

RESUMEN

A fast ellipsometry system with a resolution of only a few nanoseconds that can simultaneously measure all four Stokes parameters was developed for use in dynamic experiments. Due to its fine temporal resolution, the system is useful for a wide variety of dynamic setups, two of which are presented, fast foil heating and shock compression. As a test case the optical properties of nickel were measured in a fast foil heating setup. The complex index of refraction and emissivity at 532 nm and in the range of 1000-1900 K are presented. It was found that the emissivity monotonously increases below and above the melting point while an abrupt increase of about 2% was observed at the phase transition. These results are in accordance with the literature. Shock compression experiments included sample-free surface measurements. Samples of 1020 steel were shocked up to 25 GPa on the Hugoniot curve. The measured optical properties under these conditions showed a significant change; the value of the emissivity was doubled.

3.
Rev Sci Instrum ; 82(3): 033905, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21456761

RESUMEN

High pressure ellipsometry (HPE) method was developed for determining the index of refraction of opaque materials in a diamond anvil cell (DAC). A main difficulty in DAC-based HPE, namely, the pressure-induced birefringence developed in the diamond, was overcome enabling the extraction of the ellipsometric parameters of the sample. The method used was based on the fact that an unpolarized light is unaffected by a retarding optical element and thus reduces the number of unknown parameters in the problem. Because of technical difficulties in using unpolarized light, a linear combination of orthogonal polarizations was applied. In the experimental procedure, multiangle measurements of the ellipsometric parameter ψ are collected at each pressure and the data is fitted together with a measurement of the near normal reflectivity, in order to extract the complex index of refraction. As a test case, this procedure was used to measure the high pressure index of refraction of iron up to 30 GPa for light with wavelengths of 532 and 633 nm. From the index of refraction as a function of pressure the diamond-iron interface emissivity for different pressures was derived and from which the phase transition α → ε could be identified and characterized. The emissivity increases with pressure both at the α (0-9 GPa) and the ε phase (21-30 GPa) however decreases at the mixed α - ε (9-21 GPa) range. From the imaginary part of the index of refraction the pressure dependence of the energy skin depth of iron was extracted. It was found that the energy skin depth increases by an order of magnitude at 30 GPa relative to ambient conditions.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA