Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
AJNR Am J Neuroradiol ; 42(9): 1591-1597, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34167960

RESUMEN

BACKGROUND AND PURPOSE: The reliability of contrast-enhanced MRA in monitoring serial volumetric changes of unruptured intracranial aneurysms has not been established. We aimed to determine the coefficient of variance of contrast-enhanced MRA in measuring aneurysm volumes, thus establishing criteria for aneurysm growth and permitting identification of variables predictive of growth. MATERIALS AND METHODS: Aneurysm volumes were measured from serial contrast-enhanced MRA studies of patients with untreated intracranial aneurysms who underwent >2 sequential MR imaging evaluations. After coregistering all sequential studies in 3D space for each aneurysm and signal intensity normalization, aneurysm volume was determined across all time points. A linear mixed effects model was built to estimate the coefficient of variance of the measurement as well as to determine predictive variables. Growth was defined as relative growth exceeding 2 times the measurement coefficient of variance (sudden growth, as 4 times the coefficient of variance). RESULTS: A total of 95 patients with 112 aneurysms were included (5.9 scans during 4.0 years on average, 616 scan measurements in total). The coefficient of variance was 5.5% of the aneurysm volume, and the relative growth rate was dependent on the location: anterior cerebral artery, 4.52% per year; vertebral artery, 2.46% per year; middle cerebral artery, 2.74% per year; basilar artery, 2.36% per year; internal carotid artery, 1.14% per year. Thirty-six of 112 (32%) aneurysms were characterized as growing, and 11/36 of them had an episode of sudden growth. CONCLUSIONS: Volume measurement of unruptured intracranial aneurysms by contrast-enhanced MRA seems a reliable metric for tracking the growth trajectory of aneurysms. Furthermore, the aneurysm growth rate differs among different locations.


Asunto(s)
Aneurisma Intracraneal , Arteria Carótida Interna , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Angiografía por Resonancia Magnética , Imagen por Resonancia Magnética , Reproducibilidad de los Resultados
2.
AJNR Am J Neuroradiol ; 40(5): 849-854, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-31023664

RESUMEN

BACKGROUND AND PURPOSE: Idiopathic intracranial hypertension is commonly associated with transverse sinus stenosis, a venous cause of pulsatile tinnitus. In patients with idiopathic intracranial hypertension, CSF drainage via lumbar puncture decreases intracranial pressure, which relieves the stenosis, and may provide at least temporary cessation of pulsatile tinnitus. The objective of this study was to evaluate changes in venous blood flow caused by lowered intracranial pressure in patients with pulsatile tinnitus to help identify the cause of pulsatile tinnitus. MATERIALS AND METHODS: Ten patients with suspected transverse sinus stenosis as a venous etiology for pulsatile tinnitus symptoms underwent MR imaging before and after lumbar puncture in the same session. The protocol included flow assessment and rating of pulsatile tinnitus intensity before and after lumbar puncture and MR venography before lumbar puncture. Post-lumbar puncture MR venography was performed in 1 subject. RESULTS: There was a lumbar puncture-induced reduction in venous peak velocity that correlated with the opening pressure (r = -0.72, P = .019) without a concomitant reduction in flow rate. Patients with flow jets had their peak velocity reduced by 0.30 ± 0.18 m/s (P = .002), correlating with a reduction in CSF pressure (r = 0.82, P = .024) and the reduction in subjectively scored pulsatile tinnitus intensity (r = 0.78, P = .023). The post-lumbar puncture MR venography demonstrated alleviation of the stenosis. CONCLUSIONS: Our results show a lumbar puncture-induced reduction in venous peak velocity without a concomitant reduction in flow rate. We hypothesize that the reduction is caused by the expansion of the stenosis after lumbar puncture. Our results further show a correlation between the peak velocity and pulsatile tinnitus intensity, suggesting the flow jet to be instrumental in the development of sound.


Asunto(s)
Circulación Cerebrovascular/fisiología , Hemodinámica/fisiología , Punción Espinal , Acúfeno/fisiopatología , Acúfeno/cirugía , Adulto , Constricción Patológica/complicaciones , Constricción Patológica/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Seudotumor Cerebral/complicaciones , Seudotumor Cerebral/fisiopatología , Seudotumor Cerebral/cirugía , Punción Espinal/métodos , Acúfeno/etiología , Senos Transversos/patología , Senos Transversos/fisiopatología
3.
AJNR Am J Neuroradiol ; 39(11): 2108-2113, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30309843

RESUMEN

BACKGROUND AND PURPOSE: Case reports demonstrate that coiling of a sigmoid sinus diverticulum can treat pulsatile tinnitus. We hypothesized that MR imaging 4D flow and computational fluid dynamics would reveal distinct blood flow patterns in the venous outflow tract in these patients. MATERIALS AND METHODS: Patients with pulsatile tinnitus of suspected venous etiology underwent MR imaging at 3T, using venous phase contrast-enhanced MR angiography, 4D flow, and 2D phase contrast. The contrast-enhanced MRA contours were evaluated to determine the presence and extent of a sigmoid sinus diverticulum. Computational fluid dynamics analysis was performed using the 4D flow inlet flow and the luminal contours from contrast-enhanced MRA as boundary conditions. In addition, computational fluid dynamics was performed for the expected post treatment conditions by smoothing the venous geometry to exclude the sigmoid sinus diverticulum from the anatomic boundary conditions. Streamlines were generated from the 4D flow and computational fluid dynamics velocity maps, and flow patterns were examined for the presence of rotational components. RESULTS: Twenty-five patients with pulsatile tinnitus of suspected venous etiology and 10 control subjects were enrolled. Five (20%) of the symptomatic subjects had sigmoid sinus diverticula, all associated with an upstream stenosis. In each of these patients, but none of the controls, a stenosis-related flow jet was directed toward the opening of the sigmoid sinus diverticulum with rotational flow patterns in the sigmoid sinus diverticulum and parent sigmoid sinus on both 4D flow and computational fluid dynamics. CONCLUSIONS: Consistent patterns of blood flow can be visualized in a sigmoid sinus diverticulum and the parent sinus using 4D flow and computational fluid dynamics. Strong components of rotational blood flow were seen in subjects with sigmoid sinus diverticula that were absent in controls.


Asunto(s)
Circulación Cerebrovascular/fisiología , Senos Craneales/fisiopatología , Divertículo/fisiopatología , Acúfeno/etiología , Adulto , Anciano , Senos Craneales/diagnóstico por imagen , Divertículo/diagnóstico por imagen , Femenino , Hemodinámica , Humanos , Hidrodinámica , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA