Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Electrophoresis ; 37(5-6): 826-33, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26799761

RESUMEN

In the present study, for the first time electromembrane extraction followed by high performance liquid chromatography coupled with ultraviolet detection was optimized and validated for quantification of four gonadotropin-releasing hormone agonist anticancer peptides (alarelin, leuprolide, buserelin and triptorelin) in biological and aqueous samples. The parameters influencing electromigration were investigated and optimized. The membrane consists 95% of 1-octanol and 5% di-(2-ethylhexyl)-phosphate immobilized in the pores of a hollow fiber. A 20 V electrical field was applied to make the analytes migrate from sample solution with pH 7.0, through the supported liquid membrane into an acidic acceptor solution with pH 1.0 which was located inside the lumen of hollow fiber. Extraction recoveries in the range of 49 and 71% within 15 min extraction time were obtained in different biological matrices which resulted in preconcentration factors in the range of 82-118 and satisfactory repeatability (7.1 < RSD% < 19.8). The method offers good linearity (2.0-1000 ng/mL) with estimation of regression coefficient higher than 0.998. The procedure allows very low detection and quantitation limits of 0.2 and 0.6 ng/mL, respectively. Finally, it was applied to determination and quantification of peptides in human plasma and wastewater samples and satisfactory results were yielded.


Asunto(s)
Antineoplásicos Hormonales/aislamiento & purificación , Técnicas Electroquímicas/instrumentación , Hormona Liberadora de Gonadotropina/agonistas , Membranas Artificiales , Aguas Residuales/química , Contaminantes Químicos del Agua/aislamiento & purificación , Antineoplásicos Hormonales/análisis , Antineoplásicos Hormonales/sangre , Antineoplásicos Hormonales/química , Técnicas Electroquímicas/métodos , Humanos , Modelos Lineales , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Contaminantes Químicos del Agua/análisis , Contaminantes Químicos del Agua/sangre , Contaminantes Químicos del Agua/química
2.
Electrophoresis ; 35(17): 2446-53, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24788937

RESUMEN

A simple electromembrane extraction (EME) procedure combined with ion chromatography (IC) was developed to quantify inorganic anions in different pure water samples and water miscible organic solvents. The parameters affecting extraction performance, such as supported liquid membrane (SLM) solvent, extraction time, pH of donor and acceptor solutions, and extraction voltage were optimized. The optimized EME conditions were as follows: 1-heptanol was used as the SLM solvent, the extraction time was 10 min, pHs of the acceptor and donor solutions were 10 and 7, respectively, and the extraction voltage was 15 V. The mobile phase used for IC was a combination of 1.8 mM sodium carbonate and 1.7 mM sodium bicarbonate. Under these optimized conditions, all anions had enrichment factors ranging from 67 to 117 with RSDs between 7.3 and 13.5% (n = 5). Good linearity values ranging from 2 to 1200 ng/mL with coefficients of determination (R(2) ) between 0.987 and 0.999 were obtained. The LODs of the EME-IC method ranged from 0.6 to 7.5 ng/mL. The developed method was applied to different samples to evaluate the feasibility of the method for real applications.


Asunto(s)
Aniones/análisis , Cromatografía por Intercambio Iónico/métodos , Técnicas Electroquímicas/métodos , Solventes/química , Agua/química , Concentración de Iones de Hidrógeno , Membranas Artificiales , Compuestos Orgánicos/química
3.
J Sep Sci ; 36(19): 3256-63, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23894042

RESUMEN

An electromembrane extraction procedure coupled with HPLC and visible detection was applied for the extraction of three textile azo dyes as organic salts. The extraction parameters such as extraction time, applied voltage, pH range, and concentration of salt added were optimized. A driving force of 60 V was applied to extract the analytes through 2-nitrophenyl octyl ether, used as the supported liquid membrane, into a neutral aqueous solution. This method required 20 min extraction time from a neutral sample solution. The proposed microextraction technique provided good linearity with correlation coefficients from 0.996 to 0.998 over a concentration range of 1.0-1000.0 ng/mL. The LODs of dyes were 0.30-0.75 ng/mL, while the reproducibility ranged from 6.7 to 12.9% (n = 6). Also, enrichment factors of 96-162 that corresponded to the recoveries ranging from 48 to 81% were achieved. Finally, the application of this new method was demonstrated on wastewater samples and some plants grown in contaminated environments. Excellent selectivity was obtained as no interfering peaks were detected.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA