Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
1.
Phys Rev Lett ; 114(23): 231302, 2015 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-26196790

RESUMEN

New data are reported from the operation of a 2 liter C3F8 bubble chamber in the SNOLAB underground laboratory, with a total exposure of 211.5 kg days at four different energy thresholds below 10 keV. These data show that C3F8 provides excellent electron-recoil and alpha rejection capabilities at very low thresholds. The chamber exhibits an electron-recoil sensitivity of <3.5×10(-10) and an alpha rejection factor of >98.2%. These data also include the first observation of a dependence of acoustic signal on alpha energy. Twelve single nuclear recoil event candidates were observed during the run. The candidate events exhibit timing characteristics that are not consistent with the hypothesis of a uniform time distribution, and no evidence for a dark matter signal is claimed. These data provide the most sensitive direct detection constraints on WIMP-proton spin-dependent scattering to date, with significant sensitivity at low WIMP masses for spin-independent WIMP-nucleon scattering.


Asunto(s)
Fluorocarburos/química , Modelos Teóricos , Acústica/instrumentación , Algoritmos , Neutrones
2.
J Vet Intern Med ; 38(1): 285-299, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38084870

RESUMEN

BACKGROUND: High-salt diets promote urine dilution and decrease urolithiasis risk. OBJECTIVE: Prospectively evaluate the safety of chronic high dietary salt intake (randomized controlled trial). ANIMALS: Twenty research colony neutered, healthy aged cats (11.5 years [10.0-11.6], median [interquartile range]). METHODS: Healthy cats were randomized to control or high-salt dry diets (sodium: 1.02 ± 0.16 [mean, SD] and 3.26 ± 0.30 g/Mcal metabolizable energy [ME], respectively; chloride: 2.26 ± 0.33 and 5.71 ± 0.28 g/Mcal ME, respectively), fed for up to 60 months. Assessments included CBC, plasma biochemistry, urinalysis, glomerular filtration rate (GFR), blood pressure, renal and cardiac (conventional Doppler and 2-dimensional color tissue Doppler) imaging, annually. Cats that died or were euthanized underwent necropsy. Diet effects over time were evaluated with linear mixed models. RESULTS: Follow-up duration (median [Interquartile range]) was similar between the control (38.7 months [28.6-48.2]) and high-salt group (51.4 months [45.7-59.0]). Diet had no significant effect on changes in GFR, blood pressure, plasma creatinine concentration, end-diastolic left ventricular (LV) wall thicknesses, LV internal diameters, LV systolic function, left atrial size, or systolic and diastolic Doppler variables. One control cat developed hypertension. One high-salt group cat developed persistent azotemia. Serial plasma biochemistry and urine specific gravity suggested early chronic kidney disease in 4 nonazotemic cats (2 per group), consistent with necropsy findings. CONCLUSIONS AND CLINICAL IMPORTANCE: In healthy aged cats, a commercial veterinary diet containing 3.26 ± 0.30 g/Mcal ME sodium was safe with regard to renal and cardiac function for up to 5 years.


Asunto(s)
Arachis , Cloruro de Sodio Dietético , Gatos , Animales , Cloruro de Sodio Dietético/efectos adversos , Estudios Prospectivos , Riñón , Sodio
3.
J Feline Med Surg ; 25(5): 1098612X231171434, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37226706

RESUMEN

OBJECTIVES: The aim of the study was to compare the diagnostic performances of a smartphone-based colorimetric method (SBCM) for urinalysis with a semi-automated point-of-care (POC) analyser using standardised solutions and cat urine. METHODS: Artificial solutions (negative and positive quality controls, and purposely designed artificial urine) and natural urine from 216 cats were used. Two urine reagent strips were simultaneously dipped in each sample. One dipstick was read by the SBCM and the other by the POC analyser at the same time. Results for pH, proteins, bilirubin, 'blood', glucose and ketones were considered. Overall agreement and sensitivity, specificity and accuracy of the SBCM were determined based on selected cut-offs. RESULTS: For the artificial solutions, 80 comparisons were obtained for each analyte and each expected concentration. The overall agreement (exactly the same result) between the two methods was 78.4%. SBCM sensitivity, specificity and accuracy were 99.0%, 100% and 99.3%, respectively. The correlation between the two methods was almost perfect (Cohen's kappa coefficient = 0.9851). For natural urine samples, the overall agreement (including pH) was 68.6%. Using optimal cut-offs for the SBCM determined from the results of analysis of artificial solutions, the sensitivity, specificity and accuracy of the SBCM were 100%, 76.02% and 80.5%, respectively. In this situation, the correlation between the two methods was moderate (Cohen's kappa coefficient = 0.5401). This was mostly due to a high rate of false-positive results for bilirubin (61.1%). CONCLUSIONS AND RELEVANCE: With proper cut-off use (ie, considering positive or negative results) the SBCM evaluated here has a perfect sensitivity and appropriate diagnostic performances for proteins, 'blood', glucose and ketones. Based on these experimental data, this method appears suitable for dipstick urinalysis but positive results for bilirubin and proteins have to be confirmed.


Asunto(s)
Colorimetría , Teléfono Inteligente , Gatos , Animales , Colorimetría/veterinaria , Urinálisis/veterinaria , Glucosa , Bilirrubina , Cetonas
4.
JFMS Open Rep ; 9(1): 20551169231164610, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37123554

RESUMEN

Case summary: A 3-year-old neutered domestic shorthair cat with a long history of idiopathic immune-mediated haemolytic anaemia and thrombocytopenia treated with ciclosporin and prednisolone was referred 2 months after the appearance of nodular dermatitis. A single pigmented nodule was present in the lateral carpal region of the right foreleg. The lesion was 7 mm in diameter, non-exudative and cutaneous to subcutaneous. Fine-needle aspiration of the mass revealed the presence of pigmented fungal elements. Excisional surgery was planned; in the meantime, a plaque-like lesion developed in the interorbital region. Histopathological examination confirmed the presumptive diagnosis of phaeohyphomycosis, and Exophiala spinifera was identified as the aetiological agent. Itraconazole, given orally at a dose of 10 mg/kg for 8 weeks following surgery, enabled clinical resolution despite continued use of immunosuppressants. The follow-up was carried out over 14 weeks. Relevance and novel information: This case report provides the first evidence of multifocal cutaneous phaeohyphomycosis caused by E spinifera with clinical resolution after combined surgical and itraconazole treatment in an immunocompromised cat.

5.
Eur Phys J C Part Fields ; 83(6): 467, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37303462

RESUMEN

The ICARUS collaboration employed the 760-ton T600 detector in a successful 3-year physics run at the underground LNGS laboratory, performing a sensitive search for LSND-like anomalous νe appearance in the CERN Neutrino to Gran Sasso beam, which contributed to the constraints on the allowed neutrino oscillation parameters to a narrow region around 1 eV2. After a significant overhaul at CERN, the T600 detector has been installed at Fermilab. In 2020 the cryogenic commissioning began with detector cool down, liquid argon filling and recirculation. ICARUS then started its operations collecting the first neutrino events from the booster neutrino beam (BNB) and the Neutrinos at the Main Injector (NuMI) beam off-axis, which were used to test the ICARUS event selection, reconstruction and analysis algorithms. ICARUS successfully completed its commissioning phase in June 2022. The first goal of the ICARUS data taking will be a study to either confirm or refute the claim by Neutrino-4 short-baseline reactor experiment. ICARUS will also perform measurement of neutrino cross sections with the NuMI beam and several Beyond Standard Model searches. After the first year of operations, ICARUS will search for evidence of sterile neutrinos jointly with the Short-Baseline Near Detector, within the Short-Baseline Neutrino program. In this paper, the main activities carried out during the overhauling and installation phases are highlighted. Preliminary technical results from the ICARUS commissioning data with the BNB and NuMI beams are presented both in terms of performance of all ICARUS subsystems and of capability to select and reconstruct neutrino events.

6.
Phys Rev Lett ; 106(2): 021303, 2011 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-21405218

RESUMEN

Data from the operation of a bubble chamber filled with 3.5 kg of CF3I in a shallow underground site are reported. An analysis of ultrasound signals accompanying bubble nucleations confirms that alpha decays generate a significantly louder acoustic emission than single nuclear recoils, leading to an efficient background discrimination. Three dark matter candidate events were observed during an effective exposure of 28.1 kg day, consistent with a neutron background. This observation provides strong direct detection constraints on weakly interacting massive particle (WIMP)-proton spin-dependent scattering for WIMP masses >20 GeV/c2.

7.
J Feline Med Surg ; 23(12): 1140-1148, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-33749374

RESUMEN

OBJECTIVES: The aim of this study was to develop an algorithm capable of predicting short- and medium-term survival in cases of intrinsic acute-on-chronic kidney disease (ACKD) in cats. METHODS: The medical record database was searched to identify cats hospitalised for acute clinical signs and azotaemia of at least 48 h duration and diagnosed to have underlying chronic kidney disease based on ultrasonographic renal abnormalities or previously documented azotaemia. Cases with postrenal azotaemia, exposure to nephrotoxicants, feline infectious peritonitis or neoplasia were excluded. Clinical variables were combined in a clinical severity score (CSS). Clinicopathological and ultrasonographic variables were also collected. The following variables were tested as inputs in a machine learning system: age, body weight (BW), CSS, identification of small kidneys or nephroliths by ultrasonography, serum creatinine at 48 h (Crea48), spontaneous feeding at 48 h (SpF48) and aetiology. Outputs were outcomes at 7, 30, 90 and 180 days. The machine-learning system was trained to develop decision tree algorithms capable of predicting outputs from inputs. Finally, the diagnostic performance of the algorithms was calculated. RESULTS: Crea48 was the best predictor of survival at 7 days (threshold 1043 µmol/l, sensitivity 0.96, specificity 0.53), 30 days (threshold 566 µmol/l, sensitivity 0.70, specificity 0.89) and 90 days (threshold 566 µmol/l, sensitivity 0.76, specificity 0.80), with fewer cats still alive when their Crea48 was above these thresholds. A short decision tree, including age and Crea48, predicted the 180-day outcome best. When Crea48 was excluded from the analysis, the generated decision trees included CSS, age, BW, SpF48 and identification of small kidneys with an overall diagnostic performance similar to that using Crea48. CONCLUSIONS AND RELEVANCE: Crea48 helps predict short- and medium-term survival in cats with ACKD. Secondary variables that helped predict outcomes were age, CSS, BW, SpF48 and identification of small kidneys.


Asunto(s)
Enfermedades de los Gatos , Insuficiencia Renal Crónica , Algoritmos , Animales , Enfermedades de los Gatos/diagnóstico por imagen , Gatos , Creatinina , Aprendizaje Automático , Pronóstico , Insuficiencia Renal Crónica/diagnóstico , Insuficiencia Renal Crónica/veterinaria
8.
RSC Adv ; 11(21): 12794-12801, 2021 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-35423814

RESUMEN

Despite huge advancements in the process of synthesizing small molecules as part of one-bead-one-compound (OBOC) libraries, progress lags in the ability to screen these libraries against proteins of interest. Recently, we developed a method to screen OBOC libraries in which a target protein is labeled with a near-infrared (NIR) range fluorophore. The labeled protein incubates with beads of a library in a 96-well plate, then the plate is imaged for fluorescence. Fluorescence intensities produced by the labeled protein binding the bead can be quantitated and provide a basis to rank hits. Here, we present an application of this technique by screening the oncoprotein gankyrin against a 343-member peptoid library. The library was composed of four positions occupied by one of seven amines. In the third position, an amine that facilitates covalent binding via a sulfonyl fluoride moiety was incorporated. After screening for gankyrin binders twice, ten structures showed overlap in the types of amines present at each position. These initial hits were validated with an in-gel fluorescence assay in which the labeled ligands covalently interacted with purified gankyrin. Excitingly, one peptoid was validated from this analysis. This hit was also shown to bind gankyrin in the presence of HEK 293T lysate. Results from this study demonstrate successful use of our screening method to quickly identify quality binders to a target protein of interest.

9.
Plant Pathol ; 70(6): 1486-1495, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34413548

RESUMEN

Yam (Dioscorea spp.) is a major staple food whose production is hampered by viral diseases. However, the prevalence, diversity, transmission, and impact of yam-infecting viruses remain poorly documented. This study reports on the symptomatology, prevalence, and molecular diversity of eight viruses in 38 D. rotundata accessions from a germplasm collection and 206 F1 hybrid progenies maintained in Côte d'Ivoire. Mean severity scores as assessed from leaf symptoms ranged from 2 to 4 in the germplasm collection and from 1 to 3 in F1 hybrids, respectively. Dioscorea mosaic-associated virus (DMaV), potexviruses, and yam mosaic virus (YMV) were detected by PCR-based diagnosis tools in single and mixed infections in both the D. rotundata collection and F1 progenies, whereas badnaviruses were detected only in the germplasm collection. In contrast, cucumber mosaic virus (CMV), yam macluraviruses, yam asymptomatic virus 1 (YaV1), and yam mild mosaic virus (YMMV) could not be detected. No correlation could be established between severity scores and indexing results. Phylogenetic analysis performed on partial viral sequences amplified from infected samples unveiled the presence of two putative novel viral species belonging to genera Badnavirus and Potexvirus and provided evidence for plant-to-plant transmission of YMV, DMaV, and yam potexviruses.

10.
Phys Fluids (1994) ; 33(3): 037122, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33897243

RESUMEN

This paper presents the Mechanical Ventilator Milano (MVM), a novel intensive therapy mechanical ventilator designed for rapid, large-scale, low-cost production for the COVID-19 pandemic. Free of moving mechanical parts and requiring only a source of compressed oxygen and medical air to operate, the MVM is designed to support the long-term invasive ventilation often required for COVID-19 patients and operates in pressure-regulated ventilation modes, which minimize the risk of furthering lung trauma. The MVM was extensively tested against ISO standards in the laboratory using a breathing simulator, with good agreement between input and measured breathing parameters and performing correctly in response to fault conditions and stability tests. The MVM has obtained Emergency Use Authorization by U.S. Food and Drug Administration (FDA) for use in healthcare settings during the COVID-19 pandemic and Health Canada Medical Device Authorization for Importation or Sale, under Interim Order for Use in Relation to COVID-19. Following these certifications, mass production is ongoing and distribution is under way in several countries. The MVM was designed, tested, prepared for certification, and mass produced in the space of a few months by a unique collaboration of respiratory healthcare professionals and experimental physicists, working with industrial partners, and is an excellent ventilator candidate for this pandemic anywhere in the world.

11.
Phys Rev Lett ; 105(18): 181801, 2010 Oct 29.
Artículo en Inglés | MEDLINE | ID: mdl-21231096

RESUMEN

The MiniBooNE experiment at Fermilab reports results from a search for ¯ν_{µ}→¯ν_{e} oscillations, using a data sample corresponding to 5.66×10²° protons on target. An excess of 20.9±14.0 events is observed in the energy range 475

12.
J Vet Diagn Invest ; 21(3): 364-8, 2009 May.
Artículo en Inglés | MEDLINE | ID: mdl-19407091

RESUMEN

The aim of the current study was to compare feline hematologic variables in blood collected in microcapillary tubes (20 microl) and conventional blood tubes with the Medonic CA620/530 Vet in-house hematologic analyzer. A comparison of results obtained in 60 cats presented at the clinics of the veterinary school showed that the correlations between the 2 methods were 0.97 for white blood cell, 0.95 for red blood cell, and 0.93 for platelet counts; 0.92 for hemoglobin concentration; and 0.99 for mean corpuscular volume. No clinically relevant differences between the 2 blood sampling techniques were observed for any variable, which suggests that both techniques are interchangeable in cats. Moreover, microcapillary tubes would allow easier repeated sampling in the same cat and would likely be useful in other small species.


Asunto(s)
Gatos/sangre , Pruebas Hematológicas/veterinaria , Animales , Recuento de Eritrocitos/instrumentación , Recuento de Eritrocitos/veterinaria , Pruebas Hematológicas/instrumentación , Hemoglobinas/análisis , Recuento de Leucocitos/instrumentación , Recuento de Leucocitos/veterinaria , Recuento de Plaquetas/instrumentación , Recuento de Plaquetas/veterinaria , Control de Calidad , Sensibilidad y Especificidad
13.
J Feline Med Surg ; 11(8): 633-44, 2009 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19201637

RESUMEN

This report describes a nosocomial outbreak of feline calicivirus (FCV) associated virulent systemic disease (VSD) in a French veterinary teaching hospital in 2005. The outbreak started in March and resolved within 1 month. Signs, clinical course, clinicopathological findings and lesions were typical of FCV-induced VSD. FCV infection was confirmed by quantitative reverse transcriptase-polymerase chain reaction (RT-PCR). Among the eight infected cats, two had to be euthanased, three died, and three recovered after medical treatment. Virus could not be confined inside the animal hospital and on two occasions, students' own cats became infected. Subsequent genetic sequencing studies confirmed that the eight cats were infected with the same strain of virus, and that it was distinct from those involved in the US and UK outbreaks of VSD. Virulence and viral excretion patterns of the isolated strain were further characterised by experimental infection.


Asunto(s)
Infecciones por Caliciviridae/veterinaria , Calicivirus Felino , Enfermedades de los Gatos/virología , Infección Hospitalaria/veterinaria , Brotes de Enfermedades/veterinaria , Animales , Infecciones por Caliciviridae/epidemiología , Infecciones por Caliciviridae/virología , Calicivirus Felino/genética , Calicivirus Felino/aislamiento & purificación , Enfermedades de los Gatos/epidemiología , Gatos , Infección Hospitalaria/epidemiología , Infección Hospitalaria/virología , Cartilla de ADN , Francia/epidemiología , Hospitales Veterinarios , Humanos , Entrevistas como Asunto , Masculino , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/veterinaria , Resultado del Tratamiento , Carga Viral/veterinaria
14.
Am J Vet Res ; 70(2): 176-85, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19231948

RESUMEN

OBJECTIVE: To compare 2 methods for estimation of glomerular filtration rate (GFR), study the effects of age and body size on GFR estimates, and provide a reference range for estimated GFR in clinically normal cats. ANIMALS: 57 cats. PROCEDURES: In each cat, GFR was estimated via plasma clearance of iohexol and creatinine. Results of a 1-compartmental model (CL1comp) were calibrated to a trapezoidal method estimate (CLtrap) by use of a correction formula applicable to dogs or humans and standardized to body weight; for iohexol clearance, data were also standardized to extracellular fluid volume (ECFV). For all 57 cats, method comparison was performed via agreement analysis. Reference ranges for GFR derived by the different methods were established by use of data from a subset of 51 cats after exclusion of 6 cats that were azotemic, Birman, or both. RESULTS: In 57 cats, mean CLtrap of creatinine was 0.29 mL/min/kg (13%) higher than CLtrap of iohexol. In 51 nonazotemic cats, mean CLtrap was 2.26 mL/min/kg for iohexol (reference range, 1.02 to 3.50 mL/min/kg) and 2.55 mL/min/kg for creatinine (reference range, 1.27 to 3.83 mL/min/kg). Values of GFR/kg or GFR standardized to liters of ECFV did not decrease with increasing age. A negative linear relationship was detected between body weight and estimated GFR/kg or GFR standardized to liters of ECFV. CONCLUSIONS AND CLINICAL RELEVANCE: Reference ranges for estimated GFR via plasma clearance of iohexol and creatinine should facilitate early detection of impaired renal function in cats, although body weight should be taken into account.


Asunto(s)
Creatinina/farmacocinética , Tasa de Filtración Glomerular/veterinaria , Yohexol/farmacocinética , Pruebas de Función Renal/veterinaria , Factores de Edad , Animales , Peso Corporal , Gatos , Creatinina/sangre , Pruebas de Función Renal/métodos , Tasa de Depuración Metabólica
15.
JFMS Open Rep ; 5(1): 2055116919833249, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30834132

RESUMEN

CASE SUMMARY: A 1-year-old male neutered cat was presented with a right-sided swelling of the floor of the oral cavity, causing dysphagia and hypersialorrhoea for 2 months. Fine-needle aspiration of the mass and CT were suggestive of a right sublingual sialocoele with no obvious cause. Surgical resection of the ipsilateral sublingual-mandibular salivary gland complex, as well as marsupialisation of the mucocoele, was performed. The cat recovered uneventfully. Histopathological examination of the resected specimen confirmed the diagnosis. No sign of recurrence was reported 7 months after surgery. RELEVANCE AND NOVEL INFORMATION: Overall, sialocoeles are rare in cats but sublingual mucocoele is the most common form. Diagnosis is usually straightforward and the use of CT to help localise the affected site and possibly identify a cause has been infrequently described. Surgical treatment recommendations have been updated, which also makes a refresher of this uncommon condition likely to be of interest to the feline practitioner.

16.
Am J Vet Res ; 69(4): 471-7, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18380578

RESUMEN

OBJECTIVE: To establish reference intervals of plasma biochemical values in healthy adult domestic shorthair (DSH) cats by use of controlled conditions. ANIMALS: 95 healthy client-owned cats. PROCEDURES: Food was withheld from the cats overnight. All blood samples were obtained on the same day, at the same location, and by the same investigator. Blood samples were collected from a cephalic vein into lithium heparin tubes. After centrifugation of blood samples, plasma supernatants were harvested and stored at -20 degrees C until assayed for total proteins, albumin, creatinine, urea, glucose, calcium, phosphates, sodium, chloride, potassium, and CO2 concentrations and alkaline phosphatase and alanine aminotransferase activities. RESULTS: Reference intervals in healthy adult DSH cats were 65 to 85 g/L for total proteins, 27 to 39 g/L for albumin, 89 to 207 micromol/L for creatinine, 6.6 to 11.3 mmol/L for urea, 4.1 to 8.2 mmol/L for glucose, 2.4 to 2.9 mmol/L for calcium, 1.1 to 2.1 mmol/L for phosphates, 153 to 161 mmol/L for sodium, 120 to 127 mmol/L for chloride, 3.3 to 4.2 mmol/L for potassium, 15 to 21 mmol/L for CO2, 32 to 147 U/L for alkaline phosphatase, and 34 to 123 U/L for alanine aminotransferase. CONCLUSIONS AND CLINICAL RELEVANCE: This study provided reference intervals for plasma analytes in adult DSH cats. The influence of potential confounding factors was minimized through use of controlled preanalytic and analytic conditions. However, these results cannot be extrapolated to other feline breeds or used to interpret results from other biochemical analyzers.


Asunto(s)
Análisis Químico de la Sangre/veterinaria , Gatos/sangre , Animales , Análisis Químico de la Sangre/normas , Femenino , Masculino , Valores de Referencia , Reproducibilidad de los Resultados
17.
J Am Anim Hosp Assoc ; 44(2): 51-9, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18316440

RESUMEN

Pediatric devices based on a capillary system may provide an alternative to vacuum tubes for canine blood sampling. The potential advantages are absence of vein collapse, limited blood volume sampled, and improved safety. The aim of this study was to compare routine plasma and hematological variables in seven healthy dogs using both techniques. Five biochemical analytes were measured, and a complete hematological examination and plasma exogenous creatinine clearance test were performed. No clinically relevant difference between the two techniques was observed for any variable or functional test assessed.


Asunto(s)
Recolección de Muestras de Sangre/veterinaria , Perros/sangre , Animales , Análisis Químico de la Sangre/veterinaria , Recolección de Muestras de Sangre/instrumentación , Recolección de Muestras de Sangre/métodos , Creatinina/farmacocinética , Estudios Cruzados , Femenino , Pruebas Hematológicas/veterinaria , Masculino , Distribución Aleatoria , Valores de Referencia
18.
Sci Adv ; 4(4): eaar2964, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29707637

RESUMEN

We present a range-wide assessment of sympatric western lowland gorillas Gorilla gorilla gorilla and central chimpanzees Pan troglodytes troglodytes using the largest survey data set ever assembled for these taxa: 59 sites in five countries surveyed between 2003 and 2013, totaling 61,000 person-days of fieldwork. We used spatial modeling to investigate major drivers of great ape distribution and population trends. We predicted density across each taxon's geographic range, allowing us to estimate overall abundance: 361,900 gorillas and 128,700 chimpanzees in Western Equatorial Africa-substantially higher than previous estimates. These two subspecies represent close to 99% of all gorillas and one-third of all chimpanzees. Annual population decline of gorillas was estimated at 2.7%, maintaining them as Critically Endangered on the International Union for Conservation of Nature and Natural Resources (IUCN) Red List. We quantified the threats to each taxon, of which the three greatest were poaching, disease, and habitat degradation. Gorillas and chimpanzees are found at higher densities where forest is intact, wildlife laws are enforced, human influence is low, and disease impacts have been low. Strategic use of the results of these analyses could conserve the majority of gorillas and chimpanzees. With around 80% of both subspecies occurring outside protected areas, their conservation requires reinforcement of anti-poaching efforts both inside and outside protected areas (particularly where habitat quality is high and human impact is low), diligent disease control measures (including training, advocacy, and research into Ebola virus disease), and the preservation of high-quality habitat through integrated land-use planning and implementation of best practices by the extractive and agricultural industries.


Asunto(s)
Armas de Fuego , Gorilla gorilla , Pan troglodytes , Árboles , África , Animales , Geografía , Modelos Teóricos , Densidad de Población , Dinámica Poblacional
19.
J Feline Med Surg ; 9(5): 382-6, 2007 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-17498993

RESUMEN

Using paediatric devices to collect venous blood from a cephalic vein in cats offers numerous practical advantages over traditional jugular venepuncture and vacuum closed systems: minimal restraint is required; there is minimal risk of serious injury to the cat; the discomfort associated with venepuncture is reduced by the use of small diameter (25 gauge) needles; very small volumes (200 microl) of blood are extracted; and the risk of vein collapse or haematoma is low. The aim of this study was to compare the haematological and plasma chemistry results obtained from six healthy cats using the two sampling techniques. Five plasma biochemical analytes were measured and a complete haematological examination was performed on each specimen. No clinically relevant difference between the two blood sampling techniques was observed for any variable, indicating that paediatric devices provide a useful alternative to vacuum tubes for venous blood collection in the cat.


Asunto(s)
Recuento de Células Sanguíneas/veterinaria , Recolección de Muestras de Sangre/veterinaria , Gatos/sangre , Animales , Recolección de Muestras de Sangre/instrumentación , Diseño de Equipo , Femenino , Masculino
20.
J Feline Med Surg ; 19(4): 484-492, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26534945

RESUMEN

Case series summary Six cats were diagnosed with renal abscesses. Common clinical findings were lethargy, dehydration, abdominal pain and nephromegaly. Fever was noted in half of the cases. Diagnosis was established by ultrasonography, cytological examination and bacterial culture of abscess aspirates. At least one possible contributing factor could be identified in all cases. Antibiotics were consistently used and in two cats the abscess was surgically drained. The short-term outcome was fair but the long-term outcome was dependent on the underlying condition. Relevance and novel information The results of this small case series suggest that renal abscess should be considered when nephromegaly and/or abdominal discomfort are noted. Diagnosis of renal abscess is straightforward when ultrasonography and fine-needle aspirate analysis can be performed. Medical treatment is assumed to be preferable but surgical treatment may be warranted on a case-by-case basis. Given that almost every affected cat was diagnosed with at least one comorbidity, a thorough evaluation is recommended for all cats with renal abscesses.


Asunto(s)
Absceso/veterinaria , Enfermedades de los Gatos/diagnóstico , Enfermedades Renales/veterinaria , Dolor Abdominal/etiología , Dolor Abdominal/veterinaria , Absceso/complicaciones , Absceso/diagnóstico , Animales , Antibacterianos/uso terapéutico , Biopsia con Aguja Fina/veterinaria , Enfermedades de los Gatos/diagnóstico por imagen , Enfermedades de los Gatos/patología , Gatos , Diagnóstico Diferencial , Femenino , Fiebre/etiología , Fiebre/veterinaria , Enfermedades Renales/complicaciones , Enfermedades Renales/diagnóstico , Masculino , Estudios Retrospectivos , Infecciones Urinarias/tratamiento farmacológico , Infecciones Urinarias/etiología , Infecciones Urinarias/veterinaria
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA