Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Cancer Cytopathol ; 130(8): 630-639, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35584402

RESUMEN

BACKGROUND: Whole slide imaging (WSI) adoption has been slower in cytopathology due, in part, to challenges in multifocal plane scanning on 3-dimensional cell clusters. ThinPrep and other liquid-based preparations may alleviate the issue by reducing clusters in a concentrated area. This study investigates the use of Z-stacked images for diagnostic assessment and the experience of evaluating urine ThinPrep WSI. METHODS: Thirty ThinPrep urine cases of high-grade urothelial carcinoma (n = 22) and cases of negative for high-grade urothelial carcinoma (n = 8) were included. Slides were scanned at 40× magnification without Z-stack and with Z-stack at 3 layers, 1 µm each. Six cytopathologists and 1 cytotechnologist evaluated the cases in 2 rounds with a 2-week wash-out period in a blinded manner. A Cohen's Kappa (CK) calculated concordance rates. A survey after each round evaluated participant experience. RESULTS: CK with the original report ranged from 0.606 to 1.0 (P < .05) without Z-stack and 0.533 to 1.0 (P < .05) with Z-stack both indicating substantial-to-perfect concordance. For both rounds, interobserver CK was moderate-to-perfect (0.417-1.0, P < .05). Intraobserver CK was 0.697-1.0 (P < 0.05), indicating substantial to perfect concordance. The average scan time and file size for slides without Z-stack and with Z-stack are 6.27 minute/0.827 GB and 14.06 minute/2.650 GB, respectively. Surveys demonstrated a range in comfort and use with slightly more favorable opinions for Z-stacked cases. CONCLUSIONS: Z-stack images provide minimal diagnostic benefit for urine ThinPrep WSI. In addition, Z-stacked urine WSI does not justify the prolonged scan times and larger storage needs compared to those without Z-stack.


Asunto(s)
Carcinoma de Células Transicionales , Neoplasias de la Vejiga Urinaria , Carcinoma de Células Transicionales/diagnóstico por imagen , Carcinoma de Células Transicionales/patología , Citodiagnóstico/métodos , Humanos , Proyectos Piloto , Neoplasias de la Vejiga Urinaria/diagnóstico por imagen , Neoplasias de la Vejiga Urinaria/patología , Orina
2.
Front Med (Lausanne) ; 8: 662312, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34195208

RESUMEN

Cell-free DNA (cfDNA) extracted from diverse specimen types has emerged as a high quality substrate for molecular tumor profiling. Analytical and pre-analytical challenges in the utilization of cfDNA extracted from pleural effusion supernatant (PES) are herein characterized in patients with metastatic non-small cell lung carcinoma (NSCLC). Pleural effusion specimens containing metastatic NSCLC were collected prospectively. After ThinPrep® (TP) and cell block (CB) preparation, DNA was extracted from residual PES and analyzed by gel electrophoresis for quality and quantity. Libraries were prepared and sequenced with a targeted next-generation sequencing (NGS) platform and panel clinically validated for plasma specimens. Results were compared with DNA extracted from corresponding FFPE samples that were sequenced using institutional targeted NGS assays clinically validated for solid tumor FFPE samples. Tumor (TC) and overall cellularity (OC) were evaluated. Fourteen specimens were collected from 13 patients. Median specimen volume was 180 mL (range, 35-1,400 mL). Median TC and OC on TP slides and CB sections were comparable. Median extracted DNA concentration was 7.4 ng/µL (range, 0.1-58.0 ng/µL), with >5 ng/µL DNA extracted from 10/14 specimens (71%). Mutations were identified in 10/14 specimens, including 1/3 specimens with median molecular coverage <1,000 reads. The minimal detected allelic fraction was 0.6%. NGS was falsely negative for the presence of one driver mutation. No correlation was identified between sample volume or OC, quality or quantity of extracted DNA, or mutation detection. Despite analytical and pre-analytical challenges, PES represents a robust source of DNA for NGS.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA