Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Environ Res ; 243: 117804, 2024 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-38042519

RESUMEN

Limiting the negative impact of climate change on nature and humans is one of the most pressing issues of the 21st century. Meanwhile, people in modern society spend most of the day indoors. It is therefore surprising that comparatively little attention has been paid to indoor human exposure in relation to climate change. Heat action plans have now been designed in many regions to protect people from thermal stress in their private homes and in public buildings. However, in order to be able to plan effectively for the future, reliable information is required about the long-term effects of climate change on indoor air quality and climate. The Indoor Air Quality Climate Change (IAQCC) model is an expediant tool for estimating the influence of climate change on indoor air quality. The model follows a holistic approach in which building physics, emissions, chemical reactions, mold growth and exposure are combined with the fundamental parameters of temperature and humidity. The features of the model have already been presented in an earlier publication, and it is now used for the expected climatic conditions in Central Europe, taking into account various shared socioeconomic pathway (SSP) scenarios up to the year 2100. For the test house examined in this study, the concentrations of pollutants in the indoor air will continue to rise. At the same time, the risk of mold growth also increases (the mold index rose from 0 to 4 in the worst case for very sensitive material). The biggest problem, however, is protection against heat and humidity. Massive structural improvements are needed here, including insulation, ventilation, and direct sun protection. Otherwise, the occupants will be exposed to increasing thermal discomfort, which can also lead to severe heat stress indoors.


Asunto(s)
Contaminación del Aire Interior , Contaminación del Aire , Humanos , Cambio Climático , Contaminación del Aire Interior/análisis , Humedad , Ventilación
2.
Indoor Air ; 32(3): e13021, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35347794

RESUMEN

Cleaning products contain numerous individual chemicals, which can be liberated on use. These species can react in air to form new chemical species, some of which are harmful to health. This paper uses a detailed chemical model for indoor air chemistry, to understand the chemical reactions that can occur following cleaning, assuming cleaning products with different proportions of limonene, α-pinene, and ß-pinene are used. The tests included the pure compounds, 50:50 mixtures and mixtures in proportion to the rates of reaction with ozone and the hydroxyl radical. For the 3 h following cleaning, pure α-pinene was most efficient at producing particles, pure limonene for nitrated organic material, and a 50:50 mixture of ß-pinene and limonene for formaldehyde, leading to enhancements of 1.1 µg/m3 , 400 ppt, and 1.8 ppb, respectively, compared to no cleaning. Cleaning in the afternoon enhanced concentrations of secondary pollutants for all the mixtures, owing to higher outdoor and hence indoor ozone compared to the morning. These enhancements in concentrations lasted several hours, despite the cleaning emissions only lasting for 10 min. Doubling the air exchange rate enhanced concentrations of formaldehyde and particulate matter by ~15% while reducing that of nitrated organic material by 13%. Changing product formulations has the potential to change the resulting indoor air quality and consequently, impacts on health.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire Interior , Ozono , Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/análisis , Formaldehído , Limoneno , Óxidos de Nitrógeno , Compuestos Orgánicos/química , Ozono/análisis
3.
Indoor Air ; 32(6): e13054, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35762241

RESUMEN

The importance of photolysis as an initiator of air chemistry outdoors is widely recognized, but its role in chemical processing indoors is often ignored. This paper uses recent experimental data to modify a detailed chemical model, using it to investigate the impacts of glass type, artificial indoor lighting, cloudiness, time of year and latitude on indoor photolysis rates and hence indoor air chemistry. Switching from an LED to an uncovered fluorescent tube light increased predicted indoor hydroxyl radical concentrations by ~13%. However, moving from glass that transmitted outdoor light at wavelengths above 380 nm to one that transmitted sunlight above 315 nm led to an increase in predicted hydroxyl radicals of more than 400%. For our studied species, including ozone, nitrogen oxides, nitrous acid, formaldehyde, and hydroxyl radicals, the latter were most sensitive to changes in indoor photolysis rates. Concentrations of nitrogen dioxide and formaldehyde were largely invariant, with exchange with outdoors and internal deposition controlling their indoor concentrations. Modern lights such as LEDs, together with low transmission glasses, will likely reduce the effects of photolysis indoors and the production of potentially harmful species. Research is needed on the health effects of different indoor air mixtures to confirm this conclusion.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire Interior , Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/análisis , Formaldehído/análisis , Radical Hidroxilo/análisis , Ácido Nitroso/análisis , Fotólisis
4.
Environ Sci Technol ; 54(24): 15643-15651, 2020 12 15.
Artículo en Inglés | MEDLINE | ID: mdl-33258369

RESUMEN

Activities such as household cleaning can greatly alter the composition of air in indoor environments. We continuously monitored hydrogen peroxide (H2O2) from household non-bleach surface cleaning in a chamber designed to simulate a residential room. Mixing ratios of up to 610 ppbv gaseous H2O2 were observed following cleaning, orders of magnitude higher than background levels (sub-ppbv). Gaseous H2O2 levels decreased rapidly and irreversibly, with removal rate constants (kH2O2) 17-73 times larger than air change rate (ACR). Increasing the surface-area-to-volume ratio within the room caused peak H2O2 mixing ratios to decrease and kH2O2 to increase, suggesting that surface uptake dominated H2O2 loss. Volatile organic compound (VOC) levels increased rapidly after cleaning and then decreased with removal rate constants 1.2-7.2 times larger than ACR, indicating loss due to surface partitioning and/or chemical reactions. We predicted photochemical radical production rates and steady-state concentrations in the simulated room using a detailed chemical model for indoor air (the INDCM). Model results suggest that, following cleaning, H2O2 photolysis increased OH concentrations by 10-40% to 9.7 × 105 molec cm-3 and hydroperoxy radical (HO2) concentrations by 50-70% to 2.3 × 107 molec cm-3 depending on the cleaning method and lighting conditions.


Asunto(s)
Contaminación del Aire Interior , Compuestos Orgánicos Volátiles , Contaminación del Aire Interior/análisis , Gases , Peróxido de Hidrógeno , Modelos Químicos , Compuestos Orgánicos Volátiles/análisis
5.
Indoor Air ; 30(6): 1241-1255, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32485006

RESUMEN

Effective cleaning techniques are essential for the sterilization of rooms in hospitals and industry. No-touch devices (NTDs) that use fumigants such as hydrogen peroxide (H2 O2 ), formaldehyde (HCHO), ozone (O3 ), and chlorine dioxide (OClO) are a recent innovation. This paper reports a previously unconsidered potential consequence of such cleaning technologies: the photochemical formation of high concentrations of hydroxyl radicals (OH), hydroperoxy radicals (HO2 ), organic peroxy radicals (RO2 ), and chlorine radicals (Cl) which can form harmful reaction products when exposed to chemicals commonly found in indoor air. This risk was evaluated by calculating radical production rates and concentrations based on measured indoor photon fluxes and typical fumigant concentrations during and after cleaning events. Sunlight and fluorescent tubes without covers initiated photolysis of all fumigants, and plastic-covered fluorescent tubes initiated photolysis of only some fumigants. Radical formation was often dominated by photolysis of fumigants during and after decontamination processes. Radical concentrations were predicted to be orders of magnitude greater than background levels during and immediately following cleaning events with each fumigant under one or more illumination condition. Maximum predicted radical concentrations (1.3 × 107 molecule cm-3 OH, 2.4 ppb HO2 , 6.8 ppb RO2 and 2.2 × 108 molecule cm-3 Cl) were much higher than baseline concentrations. Maximum OH concentrations occurred with O3 photolysis, HO2 with HCHO photolysis, and RO2 and Cl with OClO photolysis. Elevated concentrations may persist for hours after NTD use, depending on the air change rate and air composition. Products from reactions involving radicals could significantly decrease air quality when disinfectants are used, leading to adverse health effects for occupants.


Asunto(s)
Contaminación del Aire Interior/estadística & datos numéricos , Hospitales , Fotólisis , Cloro , Formaldehído , Procesos Fotoquímicos , Luz Solar
6.
Indoor Air ; 30(3): 459-472, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32034823

RESUMEN

Volatile organic compounds (VOCs) emitted from personal care products (PCPs) can affect indoor air quality and outdoor air quality when ventilated. In this paper, we determine a set of simplified VOC species profiles and emission rates for a range of non-aerosol PCPs. These have been constructed from individual vapor analysis from 36 products available in the UK, using equilibrium headspace analysis with selected-ion flow-tube mass spectrometry (SIFT-MS). A simplified speciation profile is created based on the observations, comprising four alcohols, two cyclic volatile siloxanes, and monoterpenes (grouped as limonene). Estimates are made for individual unit-of-activity VOC emissions for dose-usage of shampoos, shower gel, conditioner, liquid foundation, and moisturizer. We use these values as inputs to the INdoor air Detailed Chemical Model (INDCM) and compare results against real-world case-study experimental data. Activity-based emissions are then scaled based on plausible usage patterns to estimate the potential scale of annual per-person emissions for each product type (eg, 2 g limonene person-1  yr-1 from shower gels). Annual emissions from non-aerosol PCPs for the UK are then calculated (decamethylcyclopentasiloxane 0.25 ktonne yr-1 and limonene 0.15 ktonne yr-1 ) and these compared with the UK National Atmospheric Emissions Inventory estimates for non-aerosol cosmetics and toiletries.


Asunto(s)
Contaminación del Aire Interior/análisis , Cosméticos/análisis , Monitoreo del Ambiente , Compuestos Orgánicos Volátiles/análisis , Productos Domésticos
7.
Indoor Air ; 29(3): 369-379, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30663813

RESUMEN

People are an important source of pollution indoors, through activities such as cleaning, and also from "natural" emissions from breath and skin. This paper investigates natural emissions in high-occupancy environments. Model simulations are performed for a school classroom during a typical summer in a polluted urban area. The results show that classroom occupants have a significant impact on indoor ozone, which increases from ~9 to ~20 ppb when the pupils leave for lunch and decreases to ~14 ppb when they return. The concentrations of 4-OPA, formic acid, and acetic acid formed as oxidation products following skin emissions attained maximum concentrations of 0.8, 0.5, and 0.1 ppb, respectively, when pupils were present, increasing from near-zero concentrations in their absence. For acetone, methanol, and ethanol from breath emissions, maximum concentrations were ~22.3, 6.6, and 21.5 ppb, respectively, compared to 7.4, 2.1, and 16.9 ppb in their absence. A rate of production analysis showed that occupancy reduced oxidant concentrations, while enhancing formation of nitrated organic compounds, owing to the chemistry that follows from increased aldehyde production. Occupancy also changes the peroxy radical composition, with those formed through isoprene oxidation becoming relatively more important, which also has consequences for subsequent oxidant concentrations.


Asunto(s)
Contaminantes Atmosféricos/química , Contaminación del Aire Interior/análisis , Monitoreo del Ambiente/métodos , Respiración , Piel/química , Ácido Acético/análisis , Formiatos/análisis , Humanos , Ozono/análisis , Instituciones Académicas
8.
J Chem Educ ; 96(12): 2959-2967, 2019 Dec 10.
Artículo en Inglés | MEDLINE | ID: mdl-32051645

RESUMEN

Increasing demand for chemicals worldwide, depleting resources, consumer pressure, stricter legislation, and the rising cost of waste disposal are placing increasing pressure on chemical and related industries. For any organization to survive in the current arena of growing climate change laws and regulations, and increasing public influence, the issue of sustainability must be fundamental to the way it operates. A sustainable manufacturing approach will enable economic growth to be combined with environmental and social sustainability and will be realized via collaboration between a multidisciplinary community including chemists, biologists, engineers, environmental scientists, economists, experts in management, and policy makers. Hence, employees with new skills, knowledge, and experience are essential. To realize this approach, the design and development of a series of workshops encompassing systems thinking are presented here. After close consultation with industry, an annual program of interactive workshops has been designed for graduate students to go beyond examining the "greening" of chemical reactions, processes, and products, and instead embed a systems thinking approach to learning. The workshops provide a valuable insight into the issues surrounding sustainable manufacturing covering change management, commercialization, environmental impact, circular economy, legislation, and bioresources incorporating the conversion of waste into valuable products. The multidisciplinary course content incorporates industrial case studies, providing access to real business issues, and is delivered by experts from academic departments across campus and industry.

9.
Environ Sci Technol ; 52(5): 2419-2428, 2018 03 06.
Artículo en Inglés | MEDLINE | ID: mdl-29402076

RESUMEN

This review aims to encapsulate the importance, ubiquity, and complexity of indoor chemistry. We discuss the many sources of indoor air pollutants and summarize their chemical reactions in the air and on surfaces. We also summarize some of the known impacts of human occupants, who act as sources and sinks of indoor chemicals, and whose activities (e.g., cooking, cleaning, smoking) can lead to extremely high pollutant concentrations. As we begin to use increasingly sensitive and selective instrumentation indoors, we are learning more about chemistry in this relatively understudied environment.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire Interior , Contaminantes Ambientales , Culinaria , Humanos , Fumar
10.
Environ Sci Technol ; 49(18): 11011-8, 2015 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-26301707

RESUMEN

In the developed world, we spend most of our time indoors, where we receive the majority of our exposure to air pollution. This paper reports model simulations of PM2.5 and ozone concentrations in identical landscape offices in three European cities: Athens, Helsinki, and Milan. We compare concentrations during an intense heatwave in August 2003 with a meteorologically more typical August in 2009. During the heatwave, average indoor ozone concentrations during office hours were 44, 19, and 41 ppb in Athens, Helsinki, and Milan respectively, enhanced by 7, 4, and 17 ppb respectively relative to 2009. Total predicted PM2.5 concentrations were 13.5, 3.6, and 17.2 µg m(-3) in Athens, Helsinki, and Milan respectively, enhanced by 0.5, 0.4, and 6.7 µg m(-3) respectively relative to 2009: the three cities were affected to differing extents by the heatwave. A significant portion of the indoor PM2.5 derived from gas-phase chemistry outdoors, producing 2.5, 0.8, and 4.8 µg m(-3) of the total concentrations in Athens, Helsinki, and Milan, respectively. Despite filtering office inlet supplies to remove outdoor particles, gas-phase precursors for particles can still enter offices, where conditions are ripe for new particles to form, particularly where biogenic emissions are important outdoors. This result has important implications for indoor air quality, particularly given the current trend for green walls on buildings, which will provide a potential source of biogenic emissions near to air inlet systems.


Asunto(s)
Contaminantes Atmosféricos/química , Contaminación del Aire Interior/análisis , Modelos Teóricos , Ozono/análisis , Contaminantes Atmosféricos/análisis , Ciudades , Monitoreo del Ambiente , Finlandia , Grecia , Italia , Material Particulado/análisis
12.
Environ Sci Process Impacts ; 26(6): 975-990, 2024 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-38525871

RESUMEN

Indoor sources of air pollution, such as from cooking and cleaning, play a key role in indoor gas-phase chemistry. The focus of the impact of these activities on air quality tends to be indoors, with less attention given to the impact on air quality outside buildings. This study uses the INdoor CHEmical Model in Python (INCHEM-Py) and the Advanced Dispersion Modelling System (ADMS) to quantify the impact cooking and cleaning have on indoor and outdoor air quality for an idealised street of houses. INCHEM-Py has been developed to determine the concentrations of 106 indoor volatile organic compounds at the point they leave a building (defined as near-field concentrations). For a simulated 140 m long street with 10 equi-distant houses undertaking cooking and cleaning activities, the maximum downwind concentration of acetaldehyde increases from a background value of 0.1 ppb to 0.9 ppb post-cooking, whilst the maximum downwind chloroform concentrations increase from 1.2 to 6.2 ppt after cleaning. Although emissions to outdoors are higher when cooking and cleaning happen indoors, the contribution of these activities to total UK emissions of volatile organic compounds is low (less than 1%), and comprise about a quarter of those emitted from traffic across the UK. It is important to quantify these emissions, particularly as continued vehicle technology improvements lead to lower direct emissions outdoors, making indoor emissions relatively more important. Understanding how indoor pollution can affect outdoor environments, will allow better mitigation measures to be designed in the future that can take into account all sources of pollution that contribute to human exposure.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire Interior , Culinaria , Monitoreo del Ambiente , Compuestos Orgánicos Volátiles , Contaminación del Aire Interior/análisis , Contaminación del Aire Interior/estadística & datos numéricos , Contaminantes Atmosféricos/análisis , Compuestos Orgánicos Volátiles/análisis , Ciudades , Contaminación del Aire/estadística & datos numéricos , Contaminación del Aire/análisis
13.
Environ Sci Process Impacts ; 26(2): 436-450, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38258874

RESUMEN

Cleaning products emit a range of volatile organic compounds (VOCs), including some which are hazardous or can undergo chemical transformations to generate harmful secondary pollutants. In recent years, "green" cleaners have become increasingly popular, with an implicit assumption that these are better for our health and/or the environment. However, there is no strong evidence to suggest that they are better for indoor air quality compared to regular products. In this study, the VOC composition of 10 regular and 13 green cleaners was examined by headspace analysis. Monoterpenes were the most prevalent VOCs, with average total monoterpene concentrations of 8.6 and 25.0 mg L-1 for regular and green cleaners, respectively. Speciated monoterpene emissions were applied to a detailed chemical model to investigate the indoor air chemistry following a typical cleaning event. Green cleaners generally emitted more monoterpenes than regular cleaners, resulting in larger increases in harmful secondary pollutant concentrations following use, such as formaldehyde (up to 7%) and PAN species (up to 6%). However, emissions of the most reactive monoterpenes (α-terpinene, terpinolene and α-phellandrene), were observed more frequently from regular cleaners, resulting in a disproportionately large impact on the concentrations of radical species and secondary pollutants that were formed after cleaning occurred.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire Interior , Compuestos Orgánicos Volátiles , Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/análisis , Formaldehído/análisis , Compuestos Orgánicos Volátiles/análisis , Monoterpenos
15.
Sci Total Environ ; 881: 163497, 2023 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-37062317

RESUMEN

Plastic products are ubiquitous in our homes, but we know very little about emissions from these products and their subsequent impact on indoor air quality. This is the first study to systematically determine temperature-dependent emissions of volatile organic compounds from commonly used plastic consumer products found in the home. The plastic types included high-density polyethylene (HDPE), polypropylene (PP), polyethylene terephthalate (PET), polystyrene (PS) and polyester rubber. Plastic samples were exposed to increasing temperatures (between 18 and 28 °C) in controlled environmental chambers, connected to a proton-transfer-reaction time-of-flight mass-spectrometer (PTR-ToF-MS), where real-time emissions were detected. Average emission rates were determined and used to initialise an indoor air chemistry model (INCHEM-Py) at the highest and lowest experimental temperatures, to explore the impact these product emissions have on the indoor air chemistry. The PS tubing plastic proved to be the highest emitting polymer per surface area. Almost all selected VOC emissions were found to have a linear relationship with temperature. Upon observing the impacts of primary VOC emissions from plastics in modelled simulations, the hydroxyl radical concentration decreased by an average of 1.6 and 10 % relative to the baseline (with no plastics included) at 18 °C and 28 °C respectively. On the other hand, formaldehyde concentrations increased by 29 and 31.6 % relative to the baseline conditions at 18 °C and 28 °C respectively. The presence of plastic products indoors, therefore, has the potential to impact the indoor air quality.

16.
Environ Sci Process Impacts ; 25(9): 1532-1548, 2023 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-37609942

RESUMEN

Domestic cooking is a source of indoor air pollutants, including volatile organic compounds (VOCs), which can impact on indoor air quality. However, the real-time VOC emissions from cooking are not well characterised, and similarly, the resulting secondary chemistry is poorly understood. Here, selected-ion flow-tube mass spectrometry (SIFT-MS) was used to monitor the real-time VOC emissions during the cooking of a scripted chicken and vegetable stir-fry meal, in a room scale, semi-realistic environment. The VOC emissions were dominated by alcohols (70% of total emission), but also contained a range of aldehydes (14%) and terpenes (5%), largely attributable to the heating of oil and the preparation and heating of spices, respectively. The direct cooking-related VOC emissions were then simulated using the Indoor Chemical Model in Python (INCHEM-Py), to investigate the resulting secondary chemistry. Modelling revealed that VOC concentrations were dominated by direct emissions, with only a small contribution from secondary products, though the secondary species were longer lived than the directly emitted species. Following cooking, hydroxyl radical concentrations reduced by 86%, while organic peroxy radical levels increased by over 700%, later forming secondary organic nitrates, peroxyacylnitrates (PANs) and formaldehyde. Monoterpene emissions were shown to drive the formation of secondary formaldehyde, albeit to produce relatively modest concentrations (average of 60 ppt). Sensitivity analysis of the simulation conditions revealed that increasing the outdoor concentrations of ozone and NOx species (2.9× and 9×, respectively) resulted in the greatest increase in secondary product formation indoors (≈400%, 200% and 600% increase in organic nitrates, PANs and formaldehyde production, respectively). Given the fact that climate change is likely to result in increased ozone concentrations in the future, and that increased window-opening in response to rising temperatures is also likely, higher concentrations of indoor oxidants are likely in homes in the future. This work, therefore, suggests that cooking could be a more important source of secondary pollutants indoors in the future.


Asunto(s)
Contaminación del Aire Interior , Compuestos Orgánicos Volátiles , Nitratos , Culinaria , Formaldehído
17.
Sci Total Environ ; 900: 165744, 2023 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-37487894

RESUMEN

Source apportionment (SA) for indoor air pollution is challenging due to the multiplicity and high variability of indoor sources, the complex physical and chemical processes that act as primary sources, sinks and sources of precursors that lead to secondary formation, and the interconnection with the outdoor environment. While the major indoor sources have been recognized, there is still a need for understanding the contribution of indoor versus outdoor-generated pollutants penetrating indoors, and how SA is influenced by the complex processes that occur in indoor environments. This paper reviews our current understanding of SA, through reviewing information on the SA techniques used, the targeted pollutants that have been studied to date, and their source apportionment, along with limitations or knowledge gaps in this research field. The majority (78 %) of SA studies to date focused on PM chemical composition/size distribution, with fewer studies covering organic compounds such as ketones, carbonyls and aldehydes. Regarding the SA method used, the majority of studies have used Positive Matrix Factorization (31 %), Principal Component Analysis (26 %) and Chemical Mass Balance (7 %) receptor models. The indoor PM sources identified to date include building materials and furniture emissions, indoor combustion-related sources, cooking-related sources, resuspension, cleaning and consumer products emissions, secondary-generated pollutants indoors and other products and activity-related emissions. The outdoor environment contribution to the measured pollutant indoors varies considerably (<10 %- 90 %) among the studies. Future challenges for this research area include the need for optimization of indoor air quality monitoring and data selection as well as the incorporation of physical and chemical processes in indoor air into source apportionment methodology.

18.
BMJ Open ; 13(12): e081099, 2023 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-38056942

RESUMEN

INTRODUCTION: Relative to outdoor air pollution, there is little evidence examining the composition and concentrations of indoor air pollution and its associated health impacts. The INGENIOUS project aims to provide the comprehensive understanding of indoor air pollution in UK homes. METHODS AND ANALYSIS: 'Real Home Assessment' is a cross-sectional, multimethod study within INGENIOUS. This study monitors indoor air pollutants over 2 weeks using low-cost sensors placed in three rooms in 300 Born in Bradford (BiB) households. Building audits are completed by researchers, and participants are asked to complete a home survey and a health and behaviour questionnaire, in addition to recording household activities and health symptoms on at least 1 weekday and 1 weekend day. A subsample of 150 households will receive more intensive measurements of volatile organic compound and particulate matter for 3 days. Qualitative interviews conducted with 30 participants will identify key barriers and enablers of effective ventilation practices. Outdoor air pollution is measured in 14 locations across Bradford to explore relationships between indoor and outdoor air quality. Data will be analysed to explore total concentrations of indoor air pollutants, how these vary with building characteristics, and whether they are related to health symptoms. Interviews will be analysed through content and thematic analysis. ETHICS AND DISSEMINATION: Ethical approval has been obtained from the NHS Health Research Authority Yorkshire and the Humber (Bradford Leeds) Research Ethics Committee (22/YH/0288). We will disseminate findings using our websites, social media, publications and conferences. Data will be open access through the BiB, the Open Science Framework and the UK Data Service.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire Interior , Contaminación del Aire , Humanos , Contaminantes Atmosféricos/análisis , Estudios Transversales , Monitoreo del Ambiente/métodos , Contaminación del Aire/análisis , Material Particulado/análisis , Contaminación del Aire Interior/efectos adversos , Contaminación del Aire Interior/análisis , Reino Unido
19.
Environ Sci Technol ; 46(17): 9290-8, 2012 Sep 04.
Artículo en Inglés | MEDLINE | ID: mdl-22881450

RESUMEN

This paper reports indoor secondary organic aerosol, SOA, composition based on the results from an improved model for indoor air chemistry. The model uses a detailed chemical mechanism that is near-explicit to describe the gas-phase degradation of relevant indoor VOC species. In addition, gas-to-particle partitioning is included for oxygenated products formed from the degradation of limonene, the most ubiquitous terpenoid species in the indoor environment. The detail inherent in the chemical mechanism permits the indoor SOA composition to be reported in greater detail than currently possible using experimental techniques. For typical indoor conditions in the suburban UK, SOA concentrations are ~1 µg m(-3) and dominated by nitrated material (~85%), with smaller contributions from peroxide (12%), carbonyl (3%), and acidic (1%) material. During cleaning activities, SOA concentrations can reach 20 µg m(-3) with the composition dominated by peroxide material (73%), with a smaller contribution from nitrated material (21%). The relative importance of these different moieties depends crucially (in order) on the outdoor concentration of O(3), the deposition rates employed and the scaling factor value applied to the partitioning coefficient. There are currently few studies that report observation of aerosol composition indoors, and most of these have been carried out under conditions that are not directly relevant. This study highlights the need to investigate SOA composition in real indoor environments. Further, there is a need to measure deposition rates for key indoor air species on relevant indoor surfaces and to reduce the uncertainties that still exist in gas-to-particle phase parametrization for both indoor and outdoor air chemistry models.


Asunto(s)
Aerosoles/análisis , Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/análisis , Nitratos/análisis , Peróxidos/análisis , Monitoreo del Ambiente , Modelos Químicos
20.
Science ; 377(6610): 1045-1046, 2022 09 02.
Artículo en Inglés | MEDLINE | ID: mdl-36048941

RESUMEN

A human-occupied indoor space shares many similarities with Earth and its atmosphere.


Asunto(s)
Contaminación del Aire Interior , Cuerpo Humano , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA