J Ultrasound Med ; 43(6): 1063-1080, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38440926

RESUMEN

BACKGROUND: Acoustically activatable perfluoropropane droplets (PD) can be formulated from commercially available microbubble preparations. Diagnostic transthoracic ultrasound frequencies have resulted in acoustic activation (AA) predominately within myocardial infarct zones (IZ). OBJECTIVE: We hypothesized that the AA area following acute coronary ischemia/reperfusion (I/R) would selectively enhance the developing scar zone, and target bioeffects specifically to this region. METHODS: We administered intravenous PD in 36 rats and 20 pigs at various stages of myocardial scar formation (30 minutes, 1 day, and 7 days post I/R) to determine what effect infarct age had on the AA within the IZ. This was correlated with histology, myeloperoxidase activity, and tissue nitrite activity. RESULTS: The degree of AA within the IZ in rats was not associated with collagen content, neutrophil infiltration, or infarct age. AA within 24 hours of I/R was associated with increased nitric oxide utilization selectively within the IZ (P < .05 compared with remote zone). The spatial extent of AA in pigs correlated with infarct size only when performed before sacrifice at 7 days (r = .74, P < .01). CONCLUSIONS: Acoustic activation of intravenous PD enhances the developing scar zone following I/R, and results in selective tissue nitric oxide utilization.


Asunto(s)
Fluorocarburos , Infarto del Miocardio , Animales , Fluorocarburos/farmacocinética , Porcinos , Ratas , Infarto del Miocardio/diagnóstico por imagen , Masculino , Medios de Contraste/farmacocinética , Nanopartículas , Ratas Sprague-Dawley , Miocardio/metabolismo , Modelos Animales de Enfermedad , Daño por Reperfusión Miocárdica/diagnóstico por imagen , Microburbujas , Femenino , Ultrasonografía/métodos
2.
Proc Natl Acad Sci U S A ; 113(36): 9983-8, 2016 09 06.
Artículo en Inglés | MEDLINE | ID: mdl-27551081

RESUMEN

This study presents a unique approach to understanding the biophysical mechanisms of ultrasound-triggered cell membrane disruption (i.e., sonoporation). We report direct correlations between ultrasound-stimulated encapsulated microbubble oscillation physics and the resulting cellular membrane permeability by simultaneous microscopy of these two processes over their intrinsic physical timescales (microseconds for microbubble dynamics and seconds to minutes for local macromolecule uptake and cell membrane reorganization). We show that there exists a microbubble oscillation-induced shear-stress threshold, on the order of kilopascals, beyond which endothelial cellular membrane permeability increases. The shear-stress threshold exhibits an inverse square-root relation to the number of oscillation cycles and an approximately linear dependence on ultrasound frequency from 0.5 to 2 MHz. Further, via real-time 3D confocal microscopy measurements, our data provide evidence that a sonoporation event directly results in the immediate generation of membrane pores through both apical and basal cell membrane layers that reseal along their lateral area (resealing time of ∼<2 min). Finally, we demonstrate the potential for sonoporation to indirectly initiate prolonged, intercellular gaps between adjacent, confluent cells (∼>30-60 min). This real-time microscopic approach has provided insight into both the physical, cavitation-based mechanisms of sonoporation and the biophysical, cell-membrane-based mechanisms by which microbubble acoustic behaviors cause acute and sustained enhancement of cellular and vascular permeability.


Asunto(s)
Fenómenos Biofísicos , Membrana Celular/química , Sonicación/métodos , Ondas Ultrasónicas , Membrana Celular/efectos de la radiación , Permeabilidad de la Membrana Celular/efectos de la radiación , Humanos , Microburbujas
3.
Mol Pharm ; 14(3): 781-790, 2017 03 06.
Artículo en Inglés | MEDLINE | ID: mdl-28165246

RESUMEN

Imaging of angiogenesis receptors could provide a sensitive and clinically useful method for detecting neovascularization such as occurs in malignant tumors, and responses to antiangiogenic therapies for such tumors. We tested the hypothesis that microbubbles (MB) tagged with human VEGF121 (MBVEGF) bind to the kinase insert domain receptor (KDR) in vitro and angiogenic endothelium in vivo, and that this specific binding can be imaged on a clinical ultrasound system. In this work, targeted adhesion of MBVEGF was evaluated in vitro using a parallel plate flow system containing adsorbed recombinant human KDR. There was more adhesion of MBVEGF to KDR-coated plates when the amount of VEGF121 on each MB or KDR density on the plate was increased. MBVEGF adhesion to KDR-coated plates decreased with increasing wall shear rate. On intravital microscopic imaging of bFGF-stimulated rat cremaster muscle, there was greater microvascular adhesion of MBVEGF compared to that of isotype IgG-conjugated control MB (MBCTL). To determine if MBVEGF could be used to ultrasonically image angiogenesis, ultrasound imaging was performed in mice bearing squamous cell carcinoma after intravenous injection of MBVEGF. Ultrasound videointensity enhancement in tumor was significantly higher for MBVEGF (17.3 ± 9.7 dB) compared to MBCTL (3.8 ± 4.4 dB, n = 6, p < 0.05). This work demonstrates the feasibility of targeted ultrasound imaging of an angiogenic marker using MBVEGF. This approach offers a noninvasive bedside method for detecting tumor angiogenesis and could be extended to other applications such as molecular monitoring of therapeutic angiogenesis or antiangiogenic therapies in cardiovascular disease or cancer.


Asunto(s)
Medios de Contraste/química , Neovascularización Patológica/diagnóstico , Factor A de Crecimiento Endotelial Vascular/química , Factor A de Crecimiento Endotelial Vascular/metabolismo , Inhibidores de la Angiogénesis/farmacología , Animales , Carcinoma de Células Escamosas/diagnóstico , Carcinoma de Células Escamosas/metabolismo , Modelos Animales de Enfermedad , Femenino , Humanos , Ratones , Ratones Endogámicos C3H , Microburbujas , Imagen Molecular/métodos , Neovascularización Patológica/metabolismo , Ratas , Ratas Sprague-Dawley , Ratas Wistar , Ultrasonografía/métodos , Receptor 2 de Factores de Crecimiento Endotelial Vascular/metabolismo
4.
Mol Pharm ; 13(1): 55-64, 2016 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-26567985

RESUMEN

Cardiotoxicity is the major dose-limiting factor in the chemotherapeutic use of doxorubicin (Dox). A delivery vehicle that can be triggered to release its payload in the tumoral microvasculature but not in healthy tissue would help improve the therapeutic window of the drug. Delivery strategies combining liposomal encapsulated Dox (LDox), microbubbles (MBs), and ultrasound (US) have been shown to improve therapeutic efficacy of LDox, but much remains to be known about the mechanisms and the US conditions that maximize cytotoxicity using this approach. In this study, we compared different US pulses in terms of drug release and acute toxicity. Drug uptake and proliferation rates using low-intensity US were measured in squamous cell carcinoma cells exposed to LDox conjugated to or coinjected with polymer MBs. The aims of this study were: (1) to compare the effects of low- and high-pressure US on Dox release kinetics; (2) to evaluate whether conjugating the liposome to the MB surface (DoxLPX) is an important factor for drug release and cytotoxicity; and (3) to determine which US parameters most inhibit cell proliferation and whether this inhibition is mediated by drug release or the MB/US interaction with cells. Low-pressure US (170 kPa) at high duty cycle (stable cavitation) released up to ∼ 70% of the encapsulated Dox from the DoxLPX, thus improving Dox bioavailability and cellular uptake and leading to a significant reduction in cell proliferation at 48 h. Flow cytometry showed that US generating stable oscillations of DoxLPX significantly increased cellular Dox uptake at 4 h after US exposure compared to LDox. Drug uptake was correlated with cytotoxicity at 48 h. Our results demonstrate that Dox-containing liposomes conjugated to polymer MBs can be triggered to release ∼ 70% of their payload using noninertial US. Following release, Dox became bioavailable to the cells and induced significantly higher cytotoxicity compared to nonreleased encapsulated drug. Our findings show promise for targeted drug delivery using this theranostic delivery platform at low US intensities.


Asunto(s)
Doxorrubicina/análogos & derivados , Sistemas de Liberación de Medicamentos/métodos , Microburbujas , Polímeros/química , Doxorrubicina/química , Polietilenglicoles/química , Ultrasonido
5.
J Acoust Soc Am ; 139(1): 204-14, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26827018

RESUMEN

Ultrasound-stimulated microbubble dynamics have been shown to be dependent on intrinsic bubble properties, including size and shell characteristics. The effect of the surrounding environment on microbubble response, however, has been less investigated. In particular, microbubble optimization studies are generally conducted in water/saline, characterized by a 1 cP viscosity, for application in the vasculature (i.e., 4 cP). In this study, ultra-high speed microscopy was employed to investigate fluid viscosity effects on phospholipid encapsulated microbubble oscillations at 1 MHz, using a single, eight-cycle pulse at peak negative pressures of 100 and 250 kPa. Microbubble oscillations were shown to be affected by fluid viscosity in a size- and pressure-dependent manner. In general, the oscillation amplitudes exhibited by microbubbles between 3 and 6 µm in 1 cP fluid were larger than in 4 cP fluid, reaching a maximum of 1.7-fold at 100 kPa for microbubbles 3.8 µm in diameter and 1.35-fold at 250 kPa for microbubbles 4.8 µm in diameter. Simulation results were in broad agreement at 250 kPa, however generally underestimated the effect of fluid viscosity at 100 kPa. This is the first experimental demonstration documenting the effects of surrounding fluid viscosity on microbubble oscillations, resulting in behavior not entirely predicted by current microbubble models.


Asunto(s)
Microburbujas , Fosfolípidos/química , Medios de Contraste/química , Ambiente , Movimiento (Física) , Ultrasonido , Viscosidad
6.
Mol Imaging ; 16(0): 1-9, 2014 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-24742373

RESUMEN

Vascular endothelial leukocyte adhesion molecules, such as E-selectin, are acutely upregulated in myocardial ischemia/reperfusion and are thus "ischemic memory" biomarkers for recent cardiac ischemia. We sought to develop an ultrasound molecular imaging agent composed of microbubbles (MBs) targeted to E-selectin to enable the differential diagnosis of myocardial ischemia in patients presenting with chest pain of unclear etiology. Biodegradable polymer MBs were prepared bearing a peptide with specific human E-selectin affinity (MBESEL). Control MBs had scrambled peptide (MBCTL) or nonspecific IgG (MBIgG). MBESEL adhesion to activated rat endothelial cells (ECs) was confirmed in vitro in a flow system and in vivo with intravital microscopy of rat cremaster microcirculation. Ultrasound molecular imaging of recent myocardial ischemia was performed in rats 4 hours after transient (15 minutes) coronary occlusion. MBESEL adhesion was higher to inflamed versus normal ECs in vitro; there was no difference in MBCTL or MBIgG adhesion to inflamed versus normal ECs. There was greater adhesion of MBESEL to inflamed versus noninflamed microcirculation and minimal adhesion of MBCTL or MBIgG under any condition. Ultrasound imaging after injection of MBSEL demonstrated persistent contrast enhancement of the previously ischemic region. Videointensity in postischemic myocardium after MBESEL was higher than that in the nonischemic bed (11.6 ± 2.7 dB vs 3.6 ± 0.8 dB, p < .02) and higher than that after MBCTL (4.0 ± 1.0 dB, p < .03) or MBIgG (1.7 ± 0.1 dB, p < .03). MBs targeted to E-selectin via a short synthetic peptide with human E-selectin binding affinity enables echocardiographic detection of recent ischemia, setting the stage for clinical myocardial ischemic memory imaging to identify acute coronary syndromes.

7.
Mol Imaging ; 13: 1-9, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24824960

RESUMEN

Vascular endothelial leukocyte adhesion molecules, such as E-selectin, are acutely upregulated in myocardial ischemia/reperfusion and are thus "ischemic memory" biomarkers for recent cardiac ischemia. We sought to develop an ultrasound molecular imaging agent composed of microbubbles (MBs) targeted to E-selectin to enable the differential diagnosis of myocardial ischemia in patients presenting with chest pain of unclear etiology. Biodegradable polymer MBs were prepared bearing a peptide with specific human E-selectin affinity (MBESEL). Control MBs had scrambled peptide (MBCTL) or nonspecific IgG (MBIgG). MBESEL adhesion to activated rat endothelial cells (ECs) was confirmed in vitro in a flow system and in vivo with intravital microscopy of rat cremaster microcirculation. Ultrasound molecular imaging of recent myocardial ischemia was performed in rats 4 hours after transient (15 minutes) coronary occlusion. MBESEL adhesion was higher to inflamed versus normal ECs in vitro; there was no difference in MBCTL or MBIgG adhesion to inflamed versus normal ECs. There was greater adhesion of MBESEL to inflamed versus noninflamed microcirculation and minimal adhesion of MBCTL or MBIgG under any condition. Ultrasound imaging after injection of MBSEL demonstrated persistent contrast enhancement of the previously ischemic region. Videointensity in postischemic myocardium after MBESEL was higher than that in the nonischemic bed (11.6 ± 2.7 dB vs 3.6 ± 0.8 dB, p < .02) and higher than that after MBCTL (4.0 ± 1.0 dB, p < .03) or MBIgG (1.7 ± 0.1 dB, p < .03). MBs targeted to E-selectin via a short synthetic peptide with human E-selectin binding affinity enables echocardiographic detection of recent ischemia, setting the stage for clinical myocardial ischemic memory imaging to identify acute coronary syndromes.


Asunto(s)
Selectina E/metabolismo , Imagen Molecular/métodos , Isquemia Miocárdica/diagnóstico por imagen , Isquemia Miocárdica/metabolismo , Péptidos/síntesis química , Animales , Diagnóstico Diferencial , Ecocardiografía , Células Endoteliales/diagnóstico por imagen , Células Endoteliales/metabolismo , Humanos , Masculino , Microburbujas , Miocardio/metabolismo , Péptidos/metabolismo , Ratas , Ratas Sprague-Dawley
8.
Ultrasound Med Biol ; 50(3): 425-433, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38158246

RESUMEN

OBJECTIVE: Ultrasound-targeted microbubble cavitation (UTMC)-mediated blood-brain barrier (BBB) opening is being explored as a method to increase drug delivery to the brain. This strategy has progressed to clinical trials for various neurological disorders, but the underlying cellular mechanisms are incompletely understood. In the study described here, a contact co-culture transwell model of the BBB was developed that can be used to determine the signaling cascade leading to increased BBB permeability. METHODS: This BBB model consists of bEnd.3 cells and C8-D1A astrocytes seeded on opposite sides of a transwell membrane. Pulsed ultrasound (US) is applied to lipid microbubbles (MBs), and the change in barrier permeability is measured via transendothelial electrical resistance and dextran flux. Live cell calcium imaging (Fluo-4 AM) is performed during UTMC treatment. RESULTS: This model exhibits important features of the BBB, including endothelial tight junctions, and is more restrictive than the endothelial cell (EC) monolayer alone. When US is applied to MBs in contact with the ECs, BBB permeability increases in this model by two mechanisms: UTMC induces pore formation in the EC membrane (sonoporation), leading to increased transcellular permeability, and UTMC causes formation of reversible inter-endothelial gaps, which increases paracellular permeability. Additionally, this study determines that calcium influx into ECs mediates the increase in BBB permeability after UTMC in this model. CONCLUSION: Both transcellular and paracellular permeability can be used to increase drug delivery to the brain. Future studies can use this model to determine how UTMC-induced calcium-mediated signaling increases BBB permeability.


Asunto(s)
Barrera Hematoencefálica , Microburbujas , Animales , Ratones , Barrera Hematoencefálica/metabolismo , Células Endoteliales , Calcio/metabolismo , Encéfalo
9.
Sci Rep ; 14(1): 1909, 2024 01 22.
Artículo en Inglés | MEDLINE | ID: mdl-38253669

RESUMEN

The blood‒brain barrier (BBB) acts as a hindrance to drug therapy reaching the brain. With an increasing incidence of neurovascular diseases and brain cancer metastases, there is a need for an ideal in vitro model to develop novel methodologies for enhancing drug delivery to the brain. Here, we established a multicellular human brain spheroid model that mimics the BBB both architecturally and functionally. Within the spheroids, endothelial cells and pericytes localized to the periphery, while neurons, astrocytes, and microglia were distributed throughout. Ultrasound-targeted microbubble cavitation (UTMC) is a novel noninvasive technology for enhancing endothelial drug permeability. We utilized our three-dimensional (3D) model to study the feasibility and mechanisms regulating UTMC-induced hyperpermeability. UTMC caused a significant increase in the penetration of 10 kDa Texas red dextran (TRD) into the spheroids, 100 µm beyond the BBB, without compromising cell viability. This hyperpermeability was dependent on UTMC-induced calcium (Ca2+) influx and endothelial nitric oxide synthase (eNOS) activation. Our 3D brain spheroid model, with its intact and functional BBB, offers a valuable platform for studying the bioeffects of UTMC, including effects occurring spatially distant from the endothelial barrier.


Asunto(s)
Barrera Hematoencefálica , Neoplasias Encefálicas , Humanos , Preparaciones Farmacéuticas , Células Endoteliales , Encéfalo , Astrocitos
10.
Nanotheranostics ; 8(1): 33-47, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38164499

RESUMEN

Rationale: Microvascular obstruction (MVO) following percutaneous coronary intervention (PCI) is a common problem associated with adverse clinical outcomes. We are developing a novel treatment, termed sonoreperfusion (SRP), to restore microvascular patency. This entails using ultrasound-targeted microbubble cavitation (UTMC) of intravenously administered gas-filled lipid microbubbles (MBs) to dissolve obstructive microthrombi in the microvasculature. In our prior work, we used standard-sized lipid MBs. In the present study, to improve upon the efficiency and efficacy of SRP, we sought to determine the therapeutic efficacy of fibrin-targeted phase shift microbubbles (FTPSMBs) in achieving successful reperfusion of MVO. We hypothesized that owing to their much smaller size and affinity for thrombus, FTPSMBs would provide more effective dissolution of microthrombi when compared to that of the corresponding standard-sized lipid MBs. Methods: MVO in the rat hindlimb was created by direct injection of microthrombi into the left femoral artery. Definity MBs (Lantheus Medical Imaging) were infused through the jugular vein for contrast-enhanced ultrasound imaging (CEUS). A transducer was positioned vertically above the hindlimb for therapeutic US delivery during the concomitant administration of various therapeutic formulations, including (1) un-targeted MBs; (2) un-targeted phase shift microbubbles (PSMBs); (3) fibrin-targeted MB (FTMBs); and (4) fibrin-targeted PSMBs (FTPSMBs). CEUS cine loops with burst replenishment were obtained at baseline (BL), 10 min post-MVO, and after each of two successive 10-minute SRP treatment sessions (TX1, TX2) and analyzed (MATLAB). Results: In-vitro binding affinity assay showed increased fibrin binding peptide (FBP) affinity for the fibrin clots compared with the untargeted peptide (DK12). Similarly, in our in-vitro model of MVO, we observed a higher binding affinity of fluorescently labeled FTPSMBs with the porcine microthrombi compared to FTMBs, PSMBs, and MBs. Finally, in our hindlimb model, we found that UTMC with FTPSMBs yielded the greatest recovery of blood volume (dB) and flow rate (dB/sec) following MVO, compared to all other treatment groups. Conclusions: SRP with FTPSMBs achieves more rapid and complete reperfusion of MVO compared to FTMBs, PSMBs, and MBs. Studies to explore the underlying physical and molecular mechanisms are underway.


Asunto(s)
Microburbujas , Intervención Coronaria Percutánea , Ratas , Animales , Porcinos , Ultrasonografía , Péptidos , Lípidos
11.
Nanotheranostics ; 8(3): 285-297, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38577322

RESUMEN

Rationale: Microbubble (MB) contrast agents combined with ultrasound targeted microbubble cavitation (UTMC) are a promising platform for site-specific therapeutic oligonucleotide delivery. We investigated UTMC-mediated delivery of siRNA directed against epidermal growth factor receptor (EGFR), to squamous cell carcinoma (SCC) via a novel MB-liposome complex (LPX). Methods: LPXs were constructed by conjugation of cationic liposomes to the surface of C4F10 gas-filled lipid MBs using biotin/avidin chemistry, then loaded with siRNA via electrostatic interaction. Luciferase-expressing SCC-VII cells (SCC-VII-Luc) were cultured in Petri dishes. The Petri dishes were filled with media in which LPXs loaded with siRNA against firefly luciferase (Luc siRNA) were suspended. Ultrasound (US) (1 MHz, 100-µs pulse, 10% duty cycle) was delivered to the dishes for 10 sec at varying acoustic pressures and luciferase assay was performed 24 hr later. In vivo siRNA delivery was studied in SCC-VII tumor-bearing mice intravenously infused with a 0.5 mL saline suspension of EGFR siRNA LPX (7×108 LPX, ~30 µg siRNA) for 20 min during concurrent US (1 MHz, 0.5 MPa spatial peak temporal peak negative pressure, five 100-µs pulses every 1 ms; each pulse train repeated every 2 sec to allow reperfusion of LPX into the tumor). Mice were sacrificed 2 days post treatment and tumor EGFR expression was measured (Western blot). Other mice (n=23) received either EGFR siRNA-loaded LPX + UTMC or negative control (NC) siRNA-loaded LPX + UTMC on days 0 and 3, or no treatment ("sham"). Tumor volume was serially measured by high-resolution 3D US imaging. Results: Luc siRNA LPX + UTMC caused significant luciferase knockdown vs. no treatment control, p<0.05) in SCC-VII-Luc cells at acoustic pressures 0.25 MPa to 0.9 MPa, while no significant silencing effect was seen at lower pressure (0.125 MPa). In vivo, EGFR siRNA LPX + UTMC reduced tumor EGFR expression by ~30% and significantly inhibited tumor growth by day 9 (~40% decrease in tumor volume vs. NC siRNA LPX + UTMC, p<0.05). Conclusions: Luc siRNA LPXs + UTMC achieved functional delivery of Luc siRNA to SCC-VII-Luc cells in vitro. EGFR siRNA LPX + UTMC inhibited tumor growth and suppressed EGFR expression in vivo, suggesting that this platform holds promise for non-invasive, image-guided targeted delivery of therapeutic siRNA for cancer treatment.


Asunto(s)
Carcinoma de Células Escamosas , Liposomas , Animales , Ratones , Liposomas/química , ARN Interferente Pequeño/genética , Microburbujas , Carcinoma de Células Escamosas/diagnóstico por imagen , Carcinoma de Células Escamosas/genética , Carcinoma de Células Escamosas/terapia , Receptores ErbB/genética , Luciferasas
12.
Circ Cardiovasc Imaging ; 17(5): e016561, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38771901

RESUMEN

BACKGROUND: Hypertensive disorders of pregnancy (HDP) are associated with subsequent adverse cardiac remodeling and cardiovascular disease. The role of myocardial microvascular disease among individuals with HDP and left ventricular (LV) remodeling as a potential link to cardiovascular disease is unknown. We aimed to determine whether individuals with HDP history have coronary microvascular dysfunction measured by coronary flow reserve 8 to 10 years after delivery and whether microvascular dysfunction correlates with LV remodeling. METHODS: Individuals with pregnancies delivered from 2008 to 2010 underwent burst-replenishment myocardial contrast echocardiography (2017-2020) to quantify myocardial perfusion at rest and during dobutamine stress. Video intensity versus time data were used to derive ß, the rate of rise of video intensity, a correlate for myocardial blood flow. Coronary flow reserve was calculated as the ratio of ß at peak stress to ß at rest, averaged across LV myocardial regions of interest. RESULTS: We studied 91 individuals (aged 38±6 and 9.1±0.9 years postdelivery) and 19 with a history of HDP. Individuals with coronary microvascular dysfunction (coronary flow reserve <2.0; n=13) had a higher proportion of HDP (46.2% versus 16.7%; P=0.026) and higher prepregnancy body mass index, baseline heart rate, and hemoglobin A1c compared with those without microvascular dysfunction. The association of coronary flow reserve and HDP was attenuated after adjusting for cardiometabolic factors (P=0.133). In exploratory subgroup analyses, individuals with both LV remodeling (relative wall thickness >0.42) and HDP (n=12) had the highest proportion of microvascular dysfunction (41.7% versus +HDP-LV remodeling [n=7] 14.3%; -HDP+LV remodeling [n=26] 7.7%; P=0.0498). CONCLUSIONS: In this small study, HDP history is associated with coronary microvascular dysfunction 1 decade after delivery, findings that may, in part, be driven by metabolic factors including obesity and diabetes. Microvascular dysfunction may contribute to cardiovascular disease among individuals with a history of HDP.


Asunto(s)
Circulación Coronaria , Hipertensión Inducida en el Embarazo , Microcirculación , Remodelación Ventricular , Humanos , Femenino , Adulto , Embarazo , Hipertensión Inducida en el Embarazo/fisiopatología , Hipertensión Inducida en el Embarazo/diagnóstico , Función Ventricular Izquierda , Factores de Tiempo , Vasos Coronarios/fisiopatología , Vasos Coronarios/diagnóstico por imagen , Persona de Mediana Edad , Enfermedad de la Arteria Coronaria/fisiopatología , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/diagnóstico , Ecocardiografía de Estrés/métodos
13.
Ultrasound Med Biol ; 50(8): 1232-1239, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38760280

RESUMEN

BACKGROUND: Acoustically activated perfluoropropane droplets (PD) formulated from lipid encapsulated microbubble preparations produce a delayed myocardial contrast enhancement that preferentially highlights the infarct zones (IZ). Since activation of PDs may be temperature sensitive, it is unclear what effect body temperature (BT) has on acoustic activation (AA). OBJECTIVE: We sought to determine whether the microvascular retention and degree of myocardial contrast intensity (MCI) would be affected by BT at the time of intravenous injection. METHODS: We administered intravenous (IV) PD in nine rats following 60 min of ischemia followed by reperfusion. Injections in these rats were given at temperatures above and below 36.5°C, with high MI activation in both groups at 3 or 6 min following IV injection (IVI). In six additional rats (three in each group), IV PDs were given only at one temperature (<36.5°C or ≥36.5°C), permitting a total of 12 comparisons of different BT. Differences in background subtracted MCI at 3-6 min post-injection were compared in the infarct zone (IZ) and remote zone (RZ). Post-mortem lung hematoxylin and eosin (H&E) staining was performed to assess the effect potential thermal activation on lung tissue. RESULTS: Selective MCI within the IZ was observed in 8 of 12 rats who received IVI of PDs at <36.5°C, but none of the 12 rats who had IVI at the higher temperature (p < 0.0001). Absolute MCI following droplet activation was significantly higher in both the IZ and RZ when given at the lower BT. H&E indicated significant red blood extravasation in 5/7 rats who had had IV injections at higher BT, and 0/7 rats who had IV PDs at <36.5°C. CONCLUSIONS: Selective IZ enhancement with AA of intravenous PDs is possible, but temperature sensitive. Thermal activation appears to occur when PDs are given at higher temperatures, preventing AA, and increasing unwanted bioeffects.


Asunto(s)
Medios de Contraste , Fluorocarburos , Infarto del Miocardio , Ratas Sprague-Dawley , Animales , Ratas , Infarto del Miocardio/fisiopatología , Masculino , Microburbujas , Temperatura Corporal , Acústica
14.
Ultrasound Med Biol ; 49(12): 2573-2580, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37749011

RESUMEN

OBJECTIVE: Cardiac fibrosis contributes to adverse ventricular remodeling and is associated with loss of miR-29b. Overexpression of miR-29b via plasmid or intravenous injection of microRNA mimic has blunted fibrosis, but these are inefficient and non-targeted delivery strategies. In this study, we tested the hypothesis that delivery of microRNA-29b (miR-29b) using ultrasound-targeted microbubble cavitation (UTMC) of miR-29b-loaded microbubbles would attenuate cardiac fibrosis and preserve left ventricular (LV) function. METHODS: Lipid microbubbles were loaded with miR-29b mimic (miR-29b-MB) or negative control (NC) mimic (NC-MB), placed with cardiac fibroblasts (CFs) and treated with pulsed ultrasound. Cells were harvested to measure downstream fibrotic mediators. Mice received angiotensin II (ANG II) infusion causing afterload increase and direct ANG II-induced cardiac fibrosis. UTMC of miRNA-loaded microbubbles was administered to the heart at days 0, 3 and 7. Serial echocardiography was performed, and hearts were harvested on day 10. RESULTS: UTMC treatment of CFs with miR-29b-MB increased miR-29b and decreased fibrotic transcripts compared with NC-MB treatment. In vivo UTMC + NC-MB led to increased LV mass, reduction in cardiac function and increase in fibrotic markers, demonstrating ANGI II-induced adverse cardiac remodeling. Mice treated with UTMC + miR-29b-MB had preservation of cardiac function, downregulation of cardiac fibrillin and trends of lower COL1A1, COL1A2 and COL3 mRNA and decreased cardiac α-smooth muscle protein. CONCLUSION: UTMC-mediated delivery of miR-29b mimic blunts expression of fibrosis markers and preserves LV function in ANG II-induced cardiac fibrosis.


Asunto(s)
MicroARNs , Microburbujas , Ratones , Animales , MicroARNs/genética , MicroARNs/metabolismo , Fibrosis , Ecocardiografía
15.
Ultrasound Med Biol ; 49(4): 996-1006, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36697268

RESUMEN

OBJECTIVE: Ultrasound (US)-targeted microbubble (MB) cavitation (UTMC)-mediated therapies have been found to restore perfusion and enhance drug/gene delivery. Because of the potentially longer circulation time and relative ease of storage and reconstitution of polymer-shelled MBs compared with lipid MBs, we investigated the dynamic behavior of polymer microbubbles and their therapeutic potential for sonoreperfusion (SRP) therapy. METHODS: The fate of polymer MBs during a single long tone-burst exposure (1 MHz, 5 ms) at various acoustic pressures and MB concentrations was recorded via high-speed microscopy and passive cavitation detection (PCD). SRP efficacy of the polymer MBs was investigated in an in vitro flow system and compared with that of lipid MBs. DISCUSSION: Microscopy videos indicated that polymer MBs formed gas-filled clusters that continued to oscillate, fragment and form new gas-filled clusters during the single US burst. PCD confirmed continued acoustic activity throughout the 5-ms US excitation. SRP efficacy with polymer MBs increased with pulse duration and acoustic pressure similarly to that with lipid MBs but no significant differences were found between polymer and lipid MBs. CONCLUSION: These data suggest that persistent cavitation activity from polymer MBs during long tone-burst US excitation confers excellent reperfusion efficacy.


Asunto(s)
Microburbujas , Terapia por Ultrasonido , Acústica , Lípidos
16.
Transplant Proc ; 55(2): 485-495, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36878745

RESUMEN

BACKGROUND: Ischemic cholangiopathy is a process of bile duct injury that might result from peribiliary vascular plexus (PBP) thrombosis and remains a dreaded complication in liver transplantation from donors after circulatory death (DCD). The aim of this study was to propose a mechanical method of clot destruction to clear microvascular thrombi in DCD livers before transplantation. METHODS: Sonothrombolysis (STL) is a process by which inertial cavitation of circulating microbubbles entering an ultrasound field create a high-energy shockwave at a microbubble-thrombus interface, causing mechanical clot destruction. The effectiveness of STL in DCD liver treatment remains unclear. We carried out STL treatment during normothermic, oxygenated, ex vivo machine perfusion (NMP), introducing microbubbles into the perfusate with the liver enveloped in an ultrasound field. RESULTS: The STL livers showed reduction in hepatic arterial and PBP thrombus and decreases in hepatic arterial and portal venous flow resistance, reduced parenchymal injury as measured by aspartate transaminase release and oxygen consumption, and improved cholangiocyte function. Light and electron microscopy showed reduction of hepatic arterial and PBP thrombus in STL livers compared with controls and preserved hepatocyte structure, sinusoid endothelial morphology, and biliary epithelial microvilli. CONCLUSION: In this model, STL improved flow and functional measures in DCD livers undergoing NMP. These data suggest a novel therapeutic approach to treat PBP injury in DCD livers, which may ultimately increase the pool of grafts available to patients awaiting liver transplantation.


Asunto(s)
Microburbujas , Trombosis , Ratas , Animales , Preservación de Órganos/métodos , Hígado/cirugía , Perfusión/métodos , Trombosis/etiología , Trombosis/prevención & control , Supervivencia de Injerto
17.
Ultrasound Med Biol ; 49(1): 152-164, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36253230

RESUMEN

In recent years, long- and short-pulse ultrasound (US)-targeted microbubble cavitation (UTMC) has been found to increase perfusion in healthy and ischemic skeletal muscle, in pre-clinical animal models of microvascular obstruction and in the myocardium of patients presenting with acute myocardial infarction. There is evidence that the observed microvascular vasodilation is driven by the nitric oxide pathway and purinergic signaling, but the time course of the response and the dependency on US pulse length are not well elucidated. Because our prior data supported that sonoreperfusion efficacy is enhanced by long-pulse US versus short-pulse US, in this study, we sought to compare long-pulse (5000 cycles) and short-pulse (500 × 10 cycles) US at a pressure of 1.5 MPa with an equivalent total number of acoustical cycles, hence constant acoustic energy, and at the same frequency (1 MHz), in a rodent hind limb model with and without microvascular obstruction (MVO). In quantifying perfusion using burst replenishment contrast-enhanced US imaging, we made three findings: (i) Long and short pulses result in different vasodilation kinetics in an intact hind limb model. The long pulse causes an initial spasmic reduction in flow that spontaneously resolved at 4 min, followed by sustained higher flow rates (approximately twofold) compared with baseline, starting 10 min after therapy (p < 0.05). The short pulse caused a short-lived approximately twofold increase in flow rate that peaked at 4 min (p < 0.05), but without the initial spasm. (ii) The sustained increased response with the long pulse is not simply reactive hyperemia. (iii) Both pulses are effective in reperfusion of MVO in our hindlimb model by restoring blood volume, but only the long pulse caused an increase in flow rate after treatment ii, compared with MVO (p < 0.05). Histological analysis of hind limb muscle post-UTMC with either pulse configuration indicates no evidence of tissue damage or hemorrhage. Our findings indicate that the microbubble oscillation induces vasodilation, and therapeutic efficacy for the treatment of MVO can be tuned by varying pulse length; relative to short-pulse US, longer pulses drive greater microbubble cavitation and more rapid microvascular flow rate restoration after MVO, warranting further optimization of the pulse length for sonoreperfusion therapy.


Asunto(s)
Microburbujas , Terapia por Ultrasonido , Animales , Ultrasonografía , Terapia por Ultrasonido/métodos , Reperfusión , Miembro Posterior
18.
Crit Care ; 16(2): R38, 2012 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-22390813

RESUMEN

INTRODUCTION: Ultrasound measurements of brachial artery reactivity in response to stagnant ischemia provide estimates of microvascular function and conduit artery endothelial function. We hypothesized that brachial artery reactivity would independently predict severe sepsis and severe sepsis mortality. METHODS: This was a combined case-control and prospective cohort study. We measured brachial artery reactivity in 95 severe sepsis patients admitted to the medical and surgical intensive care units of an academic medical center and in 52 control subjects without acute illness. Measurements were compared in severe sepsis patients versus control subjects and in severe sepsis survivors versus nonsurvivors. Multivariable analyses were also conducted. RESULTS: Hyperemic velocity (centimeters per cardiac cycle) and flow-mediated dilation (percentage) were significantly lower in severe sepsis patients versus control subjects (hyperemic velocity: severe sepsis = 34 (25 to 48) versus controls = 63 (52 to 81), P < 0.001; flow-mediated dilation: severe sepsis = 2.65 (0.81 to 4.79) versus controls = 4.11 (3.06 to 6.78), P < 0.001; values expressed as median (interquartile range)). Hyperemic velocity, but not flow-mediated dilation, was significantly lower in hospital nonsurvivors versus survivors (hyperemic velocity: nonsurvivors = 25 (16 to 28) versus survivors = 39 (30 to 50), P < 0.001; flow-mediated dilation: nonsurvivors = 1.90 (0.68 to 3.41) versus survivors = 2.96 (0.91 to 4.86), P = 0.12). Lower hyperemic velocity was independently associated with hospital mortality in multivariable analysis (odds ratio = 1.11 (95% confidence interval = 1.04 to 1.19) per 1 cm/cardiac cycle decrease in hyperemic velocity; P = 0.003). CONCLUSIONS: Brachial artery hyperemic blood velocity is a noninvasive index of microvascular function that independently predicts mortality in severe sepsis. In contrast, brachial artery flow-mediated dilation, reflecting conduit artery endothelial function, was not associated with mortality in our severe sepsis cohort. Brachial artery hyperemic velocity may be a useful measurement to identify patients who could benefit from novel therapies designed to reverse microvascular dysfunction in severe sepsis and to assess the physiologic efficacy of these treatments.


Asunto(s)
Arteria Braquial/diagnóstico por imagen , Arteria Braquial/fisiopatología , Sepsis/fisiopatología , Área Bajo la Curva , Velocidad del Flujo Sanguíneo/fisiología , Estudios de Casos y Controles , Distribución de Chi-Cuadrado , Femenino , Humanos , Unidades de Cuidados Intensivos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Curva ROC , Reproducibilidad de los Resultados , Sepsis/mortalidad , Tasa de Supervivencia , Ultrasonografía
19.
Eur Heart J ; 32(5): 646-53, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-20581005

RESUMEN

AIMS: The density of vasa vasorum within atherosclerotic plaque correlates with histologic features of plaque vulnerability in post-mortem studies. Imaging methods to non-invasively detect vasa vasorum are limited. We hypothesized that contrast ultrasound (CUS) can quantify vasa vasorum during atherosclerosis progression. METHODS AND RESULTS: New Zealand white rabbits received a high-fat diet for 3 weeks, and bilateral femoral artery stenosis was induced by balloon injury. Contrast ultrasound femoral imaging was performed at baseline and 2, 4, and 6 weeks post injury to quantify adventitial videointensity. At each imaging time point 10 vessels were sectioned and stained with haematoxylin and eosin and von-Willebrand factor. Adventitial vasa vasorum density was quantified by counting the number of stained microvessels and their total cross-sectional area. Plaque size (per cent lumen area) progressed over time (P < 0.001), as did adventitial vasa vasorum density (P < 0.001). Plateau peak videointensity also progressed, demonstrating a strong linear correlation with histologic vasa vasorum density (P < 0.001). Receiver operating characteristic analysis indicated that a three-fold increase in median adventitial videointensity had a sensitivity of 100% and specificity of 88% for predicting abnormal neovascularization. CONCLUSION: We have histologically validated that CUS quantifies the development of adventitial vasa vasorum associated with atherosclerosis progression. This imaging technique has the potential for characterizing prognostically significant plaque features.


Asunto(s)
Aterosclerosis/patología , Arteria Femoral/patología , Placa Aterosclerótica/patología , Vasa Vasorum/patología , Animales , Aterosclerosis/diagnóstico por imagen , Proliferación Celular , Constricción Patológica/diagnóstico por imagen , Constricción Patológica/patología , Dieta Alta en Grasa , Progresión de la Enfermedad , Arteria Femoral/diagnóstico por imagen , Neovascularización Patológica/patología , Placa Aterosclerótica/ultraestructura , Conejos , Ultrasonografía Intervencional , Vasa Vasorum/diagnóstico por imagen
20.
Nanotheranostics ; 6(2): 215-229, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34976596

RESUMEN

Rationale: The treatment of microvascular obstruction (MVO) using ultrasound-targeted LNP cavitation (UTC) therapy mechanically relieves the physical obstruction in the microcirculation but does not specifically target the associated inflammatory milieu. Electrophilic fatty acid nitroalkene derivatives (nitro-fatty acids), that display pleiotropic anti-inflammatory signaling and transcriptional regulatory actions, offer strong therapeutic potential but lack a means of rapid targeted delivery. The objective of this study was to develop nitro-fatty acid-containing lipid nanoparticles (LNP) that retain the mechanical efficacy of standard LNP and can rapidly target delivery of a tissue-protective payload that reduces inflammation and improves vascular function following ischemia-reperfusion. Methods: The stability and acoustic behavior of nitro-fatty acid LNP (NO2-FA-LNP) were characterized by HPLC-MS/MS and ultra-high-speed microscopy. The LNP were then used in a rat hindlimb model of ischemia-reperfusion injury with ultrasound-targeted cavitation. Results: Intravenous administration of NO2-FA-LNP followed by ultrasound-targeted LNP cavitation (UTC) in both healthy rat hindlimb and following ischemia-reperfusion injury showed enhanced NO2-FA tissue delivery and microvascular perfusion. In addition, vascular inflammatory mediator expression and lipid peroxidation were decreased in tissues following ischemia-reperfusion revealed NO2-FA-LNP protected against inflammatory injury. Conclusions: Vascular targeting of NO2-FA-LNP with UTC offers a rapid method of focal anti-inflammatory therapy at sites of ischemia-reperfusion injury.


Asunto(s)
Nanopartículas , Espectrometría de Masas en Tándem , Animales , Ácidos Grasos/metabolismo , Isquemia , Liposomas , Ratas , Reperfusión